record(bo, "RCMP:CP07:21:LOAD") {
  field(DESC, "Rec.Cmpr1 LOAD cmd")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CCMP721_LD B 0")
  field(HIGH, "1")
  field(ZNAM, "No Load request")
  field(ONAM, "Load requested")
}

record(bo, "RCMP:CP07:21:UNLOAD") {
  field(DESC, "Rec.Cmpr1 UNLOAD cmd")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CCMP721_UL B 0")
  field(HIGH, "1")
  field(ZNAM, "No Unload request")
  field(ONAM, "Unload requested")
}

record(bo, "RCMP:CP07:21:RESET") {
  field(DESC, "Rec.Cmpr1 RESET cmd")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CCMP721_RT B 0")
  field(HIGH, "1")
  field(ZNAM, "No reset request")
  field(ONAM, "Reset requested")
}

record(stringin, "RCMP:CP07:21:SD_STRING") {
  field(DESC, "Shutdown status string")
  field(SCAN, "1 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSDSTRING721")
  field(PINI, "YES")
}

record(ai, "RCMP:CP07:21:SD_INT") {
  field(SCAN, "1 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSDINT721")
  field(DESC, "rcmp shutdown int")
  field(PREC, "2")
  field(ADEL, "0")
  field(MDEL, "0")
  field(PINI, "YES")
}

#! Further lines contain data used by VisualDCT
#! View(1522,1818,1.0)
#! Record("RCMP:CP07:21:LOAD",1520,2072,0,1,"RCMP:CP07:21:LOAD")
#! Record("RCMP:CP07:21:UNLOAD",1705,2072,0,1,"RCMP:CP07:21:UNLOAD")
#! Record("RCMP:CP07:21:RESET",1903,2072,0,1,"RCMP:CP07:21:RESET")
#! Record("RCMP:CP07:21:SD_STRING",2080,2074,0,1,"RCMP:CP07:21:SD_STRING")
#! Record("RCMP:CP07:21:SD_INT",2280,2072,0,0,"RCMP:CP07:21:SD_INT")
#! TextBox(TB0,1620,2040,2000,2000,0,"Dialog",12,1,16777215,"Utility Systems Recovery Compressor interface\n\n",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "RCMP:CP07:22:LOAD") {
  field(DESC, "Rec.Cmpr2 LOAD cmd")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CCMP722_LD B 0")
  field(HIGH, "1")
  field(ZNAM, "No Load request")
  field(ONAM, "Load requested")
}

record(bo, "RCMP:CP07:22:UNLOAD") {
  field(DESC, "Rec.Cmpr2 UNLOAD cmd")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CCMP722_UL B 0")
  field(HIGH, "1")
  field(ZNAM, "No Unload request")
  field(ONAM, "Unload requested")
}

record(bo, "RCMP:CP07:22:RESET") {
  field(DESC, "Rec.Cmpr2 RESET cmd")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CCMP722_RT B 0")
  field(HIGH, "1")
  field(ZNAM, "No reset request")
  field(ONAM, "Reset requested")
}

record(stringin, "RCMP:CP07:22:SD_STRING") {
  field(DESC, "Shutdown status string")
  field(SCAN, "1 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSDSTRING722")
  field(PINI, "YES")
}

record(ai, "RCMP:CP07:22:SD_INT") {
  field(SCAN, "1 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSDINT722")
  field(DESC, "rcmp shutdown int")
  field(PREC, "2")
  field(ADEL, "0")
  field(MDEL, "0")
  field(PINI, "YES")
}

#! Further lines contain data used by VisualDCT
#! View(1522,1818,1.0)
#! Record("RCMP:CP07:22:LOAD",1520,2072,0,1,"RCMP:CP07:22:LOAD")
#! Record("RCMP:CP07:22:UNLOAD",1705,2072,0,1,"RCMP:CP07:22:UNLOAD")
#! Record("RCMP:CP07:22:RESET",1903,2072,0,1,"RCMP:CP07:22:RESET")
#! Record("RCMP:CP07:22:SD_STRING",2080,2074,0,1,"RCMP:CP07:22:SD_STRING")
#! Record("RCMP:CP07:22:SD_INT",2280,2072,0,0,"RCMP:CP07:22:SD_INT")
#! TextBox(TB0,1620,2040,2000,2000,0,"Dialog",12,1,16777215,"Utility Systems Recovery Compressor interface\n\n",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1102:PIDTAG") {
  field(DESC, "Tank1 Prfr Discharge")
  field(PINI, "YES")
  field(VAL, "CEV11102")
}

record(ao, "CEV:CP01:1102:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11102.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1102:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11102.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1102:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11102.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1102:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11102.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1102:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11102O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1102:PIDTAG",1560,2162,0,1,"CEV:CP01:1102:PIDTAG")
#! Record("CEV:CP01:1102:ORBV",1760,2146,0,1,"CEV:CP01:1102:ORBV")
#! Record("CEV:CP01:1102:OVAL",2000,2146,0,1,"CEV:CP01:1102:OVAL")
#! Record("CEV:CP01:1102:DMIN",1760,2306,0,1,"CEV:CP01:1102:DMIN")
#! Record("CEV:CP01:1102:DMAX",2000,2306,0,1,"CEV:CP01:1102:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1102:CMD_OUT",1559,2292,0,1,"CEV:CP01:1102:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1103:PIDTAG") {
  field(DESC, "Tank1 Clean Line")
  field(PINI, "YES")
  field(VAL, "CEV11103")
}

record(ao, "CEV:CP01:1103:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11103.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1103:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11103.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1103:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11103.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1103:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11103.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1103:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11103O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1103:PIDTAG",1560,2162,0,1,"CEV:CP01:1103:PIDTAG")
#! Record("CEV:CP01:1103:ORBV",1760,2146,0,1,"CEV:CP01:1103:ORBV")
#! Record("CEV:CP01:1103:OVAL",2000,2146,0,1,"CEV:CP01:1103:OVAL")
#! Record("CEV:CP01:1103:DMIN",1760,2306,0,1,"CEV:CP01:1103:DMIN")
#! Record("CEV:CP01:1103:DMAX",2000,2306,0,1,"CEV:CP01:1103:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1103:CMD_OUT",1559,2292,0,1,"CEV:CP01:1103:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1104:PIDTAG") {
  field(DESC, "Tank1 Dirty Line")
  field(PINI, "YES")
  field(VAL, "CEV11104")
}

record(ao, "CEV:CP01:1104:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11104.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1104:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11104.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1104:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11104.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1104:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11104.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1104:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11104O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1104:PIDTAG",1560,2162,0,1,"CEV:CP01:1104:PIDTAG")
#! Record("CEV:CP01:1104:ORBV",1760,2146,0,1,"CEV:CP01:1104:ORBV")
#! Record("CEV:CP01:1104:OVAL",2000,2146,0,1,"CEV:CP01:1104:OVAL")
#! Record("CEV:CP01:1104:DMIN",1760,2306,0,1,"CEV:CP01:1104:DMIN")
#! Record("CEV:CP01:1104:DMAX",2000,2306,0,1,"CEV:CP01:1104:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1104:CMD_OUT",1559,2292,0,1,"CEV:CP01:1104:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1202:PIDTAG") {
  field(DESC, "Tank2 Prfr Discharge")
  field(PINI, "YES")
  field(VAL, "CEV11202")
}

record(ao, "CEV:CP01:1202:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11202.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1202:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11202.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1202:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11202.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1202:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11202.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1202:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11202O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1202:PIDTAG",1560,2162,0,1,"CEV:CP01:1202:PIDTAG")
#! Record("CEV:CP01:1202:ORBV",1760,2146,0,1,"CEV:CP01:1202:ORBV")
#! Record("CEV:CP01:1202:OVAL",2000,2146,0,1,"CEV:CP01:1202:OVAL")
#! Record("CEV:CP01:1202:DMIN",1760,2306,0,1,"CEV:CP01:1202:DMIN")
#! Record("CEV:CP01:1202:DMAX",2000,2306,0,1,"CEV:CP01:1202:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1202:CMD_OUT",1559,2292,0,1,"CEV:CP01:1202:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1203:PIDTAG") {
  field(DESC, "Tank2 Clean Line")
  field(PINI, "YES")
  field(VAL, "CEV11203")
}

record(ao, "CEV:CP01:1203:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11203.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1203:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11203.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1203:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11203.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1203:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11203.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1203:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11203O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1203:PIDTAG",1560,2162,0,1,"CEV:CP01:1203:PIDTAG")
#! Record("CEV:CP01:1203:ORBV",1760,2146,0,1,"CEV:CP01:1203:ORBV")
#! Record("CEV:CP01:1203:OVAL",2000,2146,0,1,"CEV:CP01:1203:OVAL")
#! Record("CEV:CP01:1203:DMIN",1760,2306,0,1,"CEV:CP01:1203:DMIN")
#! Record("CEV:CP01:1203:DMAX",2000,2306,0,1,"CEV:CP01:1203:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1203:CMD_OUT",1559,2292,0,1,"CEV:CP01:1203:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1204:PIDTAG") {
  field(DESC, "Tank2 Dirty Line")
  field(PINI, "YES")
  field(VAL, "CEV11204")
}

record(ao, "CEV:CP01:1204:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11204.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1204:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11204.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1204:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11204.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1204:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11204.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1204:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11204O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1204:PIDTAG",1560,2162,0,1,"CEV:CP01:1204:PIDTAG")
#! Record("CEV:CP01:1204:ORBV",1760,2146,0,1,"CEV:CP01:1204:ORBV")
#! Record("CEV:CP01:1204:OVAL",2000,2146,0,1,"CEV:CP01:1204:OVAL")
#! Record("CEV:CP01:1204:DMIN",1760,2306,0,1,"CEV:CP01:1204:DMIN")
#! Record("CEV:CP01:1204:DMAX",2000,2306,0,1,"CEV:CP01:1204:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1204:CMD_OUT",1559,2292,0,1,"CEV:CP01:1204:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1302:PIDTAG") {
  field(DESC, "Tank3 Prfr Discharge")
  field(PINI, "YES")
  field(VAL, "CEV11302")
}

record(ao, "CEV:CP01:1302:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11302.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1302:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11302.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1302:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11302.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1302:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11302.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1302:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11302O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1302:PIDTAG",1560,2162,0,1,"CEV:CP01:1302:PIDTAG")
#! Record("CEV:CP01:1302:ORBV",1760,2146,0,1,"CEV:CP01:1302:ORBV")
#! Record("CEV:CP01:1302:OVAL",2000,2146,0,1,"CEV:CP01:1302:OVAL")
#! Record("CEV:CP01:1302:DMIN",1760,2306,0,1,"CEV:CP01:1302:DMIN")
#! Record("CEV:CP01:1302:DMAX",2000,2306,0,1,"CEV:CP01:1302:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1302:CMD_OUT",1559,2292,0,1,"CEV:CP01:1302:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1303:PIDTAG") {
  field(DESC, "Tank3 Clean Line")
  field(PINI, "YES")
  field(VAL, "CEV11303")
}

record(ao, "CEV:CP01:1303:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11303.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1303:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11303.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1303:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11303.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1303:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11303.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1303:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11303O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1303:PIDTAG",1560,2162,0,1,"CEV:CP01:1303:PIDTAG")
#! Record("CEV:CP01:1303:ORBV",1760,2146,0,1,"CEV:CP01:1303:ORBV")
#! Record("CEV:CP01:1303:OVAL",2000,2146,0,1,"CEV:CP01:1303:OVAL")
#! Record("CEV:CP01:1303:DMIN",1760,2306,0,1,"CEV:CP01:1303:DMIN")
#! Record("CEV:CP01:1303:DMAX",2000,2306,0,1,"CEV:CP01:1303:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1303:CMD_OUT",1559,2292,0,1,"CEV:CP01:1303:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1304:PIDTAG") {
  field(DESC, "Tank3 Dirty Line")
  field(PINI, "YES")
  field(VAL, "CEV11304")
}

record(ao, "CEV:CP01:1304:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11304.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1304:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11304.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1304:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11304.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1304:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11304.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1304:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11304O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1304:PIDTAG",1560,2162,0,1,"CEV:CP01:1304:PIDTAG")
#! Record("CEV:CP01:1304:ORBV",1760,2146,0,1,"CEV:CP01:1304:ORBV")
#! Record("CEV:CP01:1304:OVAL",2000,2146,0,1,"CEV:CP01:1304:OVAL")
#! Record("CEV:CP01:1304:DMIN",1760,2306,0,1,"CEV:CP01:1304:DMIN")
#! Record("CEV:CP01:1304:DMAX",2000,2306,0,1,"CEV:CP01:1304:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1304:CMD_OUT",1559,2292,0,1,"CEV:CP01:1304:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1402:PIDTAG") {
  field(DESC, "Tank4 Prfr Discharge")
  field(PINI, "YES")
  field(VAL, "CEV11402")
}

record(ao, "CEV:CP01:1402:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11402.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1402:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11402.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1402:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11402.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1402:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11402.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1402:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11402O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1402:PIDTAG",1560,2162,0,1,"CEV:CP01:1402:PIDTAG")
#! Record("CEV:CP01:1402:ORBV",1760,2146,0,1,"CEV:CP01:1402:ORBV")
#! Record("CEV:CP01:1402:OVAL",2000,2146,0,1,"CEV:CP01:1402:OVAL")
#! Record("CEV:CP01:1402:DMIN",1760,2306,0,1,"CEV:CP01:1402:DMIN")
#! Record("CEV:CP01:1402:DMAX",2000,2306,0,1,"CEV:CP01:1402:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1402:CMD_OUT",1559,2292,0,1,"CEV:CP01:1402:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1403:PIDTAG") {
  field(DESC, "Tank4 Clean Line")
  field(PINI, "YES")
  field(VAL, "CEV11403")
}

record(ao, "CEV:CP01:1403:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11403.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1403:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11403.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1403:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11403.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1403:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11403.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1403:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11403O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1403:PIDTAG",1560,2162,0,1,"CEV:CP01:1403:PIDTAG")
#! Record("CEV:CP01:1403:ORBV",1760,2146,0,1,"CEV:CP01:1403:ORBV")
#! Record("CEV:CP01:1403:OVAL",2000,2146,0,1,"CEV:CP01:1403:OVAL")
#! Record("CEV:CP01:1403:DMIN",1760,2306,0,1,"CEV:CP01:1403:DMIN")
#! Record("CEV:CP01:1403:DMAX",2000,2306,0,1,"CEV:CP01:1403:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1403:CMD_OUT",1559,2292,0,1,"CEV:CP01:1403:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1404:PIDTAG") {
  field(DESC, "Tank4 Dirty Line")
  field(PINI, "YES")
  field(VAL, "CEV11404")
}

record(ao, "CEV:CP01:1404:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11404.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1404:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11404.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1404:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11404.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1404:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11404.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1404:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11404O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1404:PIDTAG",1560,2162,0,1,"CEV:CP01:1404:PIDTAG")
#! Record("CEV:CP01:1404:ORBV",1760,2146,0,1,"CEV:CP01:1404:ORBV")
#! Record("CEV:CP01:1404:OVAL",2000,2146,0,1,"CEV:CP01:1404:OVAL")
#! Record("CEV:CP01:1404:DMIN",1760,2306,0,1,"CEV:CP01:1404:DMIN")
#! Record("CEV:CP01:1404:DMAX",2000,2306,0,1,"CEV:CP01:1404:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1404:CMD_OUT",1559,2292,0,1,"CEV:CP01:1404:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1502:PIDTAG") {
  field(DESC, "Tank5 Prfr Discharge")
  field(PINI, "YES")
  field(VAL, "CEV11502")
}

record(ao, "CEV:CP01:1502:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11502.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1502:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11502.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1502:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11502.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1502:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11502.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1502:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11502O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1502:PIDTAG",1560,2162,0,1,"CEV:CP01:1502:PIDTAG")
#! Record("CEV:CP01:1502:ORBV",1760,2146,0,1,"CEV:CP01:1502:ORBV")
#! Record("CEV:CP01:1502:OVAL",2000,2146,0,1,"CEV:CP01:1502:OVAL")
#! Record("CEV:CP01:1502:DMIN",1760,2306,0,1,"CEV:CP01:1502:DMIN")
#! Record("CEV:CP01:1502:DMAX",2000,2306,0,1,"CEV:CP01:1502:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1502:CMD_OUT",1559,2292,0,1,"CEV:CP01:1502:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1503:PIDTAG") {
  field(DESC, "Tank5 Clean Line")
  field(PINI, "YES")
  field(VAL, "CEV11503")
}

record(ao, "CEV:CP01:1503:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11503.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1503:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11503.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1503:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11503.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1503:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11503.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1503:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11503O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1503:PIDTAG",1560,2162,0,1,"CEV:CP01:1503:PIDTAG")
#! Record("CEV:CP01:1503:ORBV",1760,2146,0,1,"CEV:CP01:1503:ORBV")
#! Record("CEV:CP01:1503:OVAL",2000,2146,0,1,"CEV:CP01:1503:OVAL")
#! Record("CEV:CP01:1503:DMIN",1760,2306,0,1,"CEV:CP01:1503:DMIN")
#! Record("CEV:CP01:1503:DMAX",2000,2306,0,1,"CEV:CP01:1503:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1503:CMD_OUT",1559,2292,0,1,"CEV:CP01:1503:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1504:PIDTAG") {
  field(DESC, "Tank5 Dirty Line")
  field(PINI, "YES")
  field(VAL, "CEV11504")
}

record(ao, "CEV:CP01:1504:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11504.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1504:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11504.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1504:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11504.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1504:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11504.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1504:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11504O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1504:PIDTAG",1560,2162,0,1,"CEV:CP01:1504:PIDTAG")
#! Record("CEV:CP01:1504:ORBV",1760,2146,0,1,"CEV:CP01:1504:ORBV")
#! Record("CEV:CP01:1504:OVAL",2000,2146,0,1,"CEV:CP01:1504:OVAL")
#! Record("CEV:CP01:1504:DMIN",1760,2306,0,1,"CEV:CP01:1504:DMIN")
#! Record("CEV:CP01:1504:DMAX",2000,2306,0,1,"CEV:CP01:1504:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1504:CMD_OUT",1559,2292,0,1,"CEV:CP01:1504:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1602:PIDTAG") {
  field(DESC, "Tank6 Prfr Discharge")
  field(PINI, "YES")
  field(VAL, "CEV11602")
}

record(ao, "CEV:CP01:1602:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11602.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1602:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11602.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1602:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11602.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1602:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11602.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1602:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11602O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1602:PIDTAG",1560,2162,0,1,"CEV:CP01:1602:PIDTAG")
#! Record("CEV:CP01:1602:ORBV",1760,2146,0,1,"CEV:CP01:1602:ORBV")
#! Record("CEV:CP01:1602:OVAL",2000,2146,0,1,"CEV:CP01:1602:OVAL")
#! Record("CEV:CP01:1602:DMIN",1760,2306,0,1,"CEV:CP01:1602:DMIN")
#! Record("CEV:CP01:1602:DMAX",2000,2306,0,1,"CEV:CP01:1602:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1602:CMD_OUT",1559,2292,0,1,"CEV:CP01:1602:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1603:PIDTAG") {
  field(DESC, "Tank6 Clean Line")
  field(PINI, "YES")
  field(VAL, "CEV11603")
}

record(ao, "CEV:CP01:1603:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11603.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1603:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11603.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1603:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11603.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1603:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11603.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1603:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11603O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1603:PIDTAG",1560,2162,0,1,"CEV:CP01:1603:PIDTAG")
#! Record("CEV:CP01:1603:ORBV",1760,2146,0,1,"CEV:CP01:1603:ORBV")
#! Record("CEV:CP01:1603:OVAL",2000,2146,0,1,"CEV:CP01:1603:OVAL")
#! Record("CEV:CP01:1603:DMIN",1760,2306,0,1,"CEV:CP01:1603:DMIN")
#! Record("CEV:CP01:1603:DMAX",2000,2306,0,1,"CEV:CP01:1603:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1603:CMD_OUT",1559,2292,0,1,"CEV:CP01:1603:CMD_OUT")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CEV:CP01:1604:PIDTAG") {
  field(DESC, "Tank6 Dirty Line")
  field(PINI, "YES")
  field(VAL, "CEV11604")
}

record(ao, "CEV:CP01:1604:ORBV") {
  field(DESC, "Current Position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11604.ORBV")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1604:OVAL") {
  field(DESC, "final position")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11604.OVAL")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1604:DMIN") {
  field(DESC, "ramp DOWN stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11604.DMIN")
  field(EGU, "%")
  field(PREC, "1")
}

record(ao, "CEV:CP01:1604:DMAX") {
  field(DESC, "ramp UP stepsize")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CEV11604.DMAX")
  field(EGU, "%")
  field(PREC, "1")
}

record(ai, "CEV:CP01:1604:CMD_OUT") {
  field(DESC, "output cmd to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CEV11604O")
  field(PREC, "2")
  field(EGU, "%")
  field(ADEL, ".01")
}

#! Further lines contain data used by VisualDCT
#! View(1438,1981,1.0)
#! Record("CEV:CP01:1604:PIDTAG",1560,2162,0,1,"CEV:CP01:1604:PIDTAG")
#! Record("CEV:CP01:1604:ORBV",1760,2146,0,1,"CEV:CP01:1604:ORBV")
#! Record("CEV:CP01:1604:OVAL",2000,2146,0,1,"CEV:CP01:1604:OVAL")
#! Record("CEV:CP01:1604:DMIN",1760,2306,0,1,"CEV:CP01:1604:DMIN")
#! Record("CEV:CP01:1604:DMAX",2000,2306,0,1,"CEV:CP01:1604:DMAX")
#! TextBox(TB0,1860,2160,2240,2120,0,"Dialog",12,1,16777215,"Utility Systems CEV valve interface\n",null)
#! Record("CEV:CP01:1604:CMD_OUT",1559,2292,0,1,"CEV:CP01:1604:CMD_OUT")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "RCMP:CP07:21:ORDER_ON") {
  field(DESC, "Rec.Cmpr1 order on")
  field(ZNAM, "not ordered on")
  field(ONAM, "ordered on")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "RCMP:CP07:21:ON_CNCL") {
  field(DESC, "Rec.Cmpr1 Cancel ON order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "RCMP:CP07:21:ORDER_OFF") {
  field(DESC, "Rec.Cmpr1 order off")
  field(ZNAM, "not order off")
  field(ONAM, "order off")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "RCMP:CP07:21:OFF_CNCL") {
  field(DESC, "Rec.Cmpr1 Cancel OFF order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "RCMP:CP07:21:ON_CFRM") {
  field(DESC, "Rec.Cmpr1 confirm ON order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
  field(OMSL, "supervisory")
}

record(bo, "RCMP:CP07:21:OFF_CFRM") {
  field(DESC, "Rec.Cmpr1 confirm OFF order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "RCMP:CP07:21:RQST_ON") {
  field(DESC, "Rec.Cmpr1 Rqst On")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CCMP721_ON B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(SCAN, "1 second")
  field(PINI, "NO")
  field(ASG, "NOWRITE")
  field(HIGH, "0")
  field(OMSL, "supervisory")
}

record(bo, "RCMP:CP07:21:RQST_OFF") {
  field(DESC, "Rec.Cmpr1 Rqst Off")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CCMP721_OF B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(ASG, "NOWRITE")
  field(PINI, "NO")
  field(HIGH, "0")
  field(SCAN, "1 second")
  field(OMSL, "supervisory")
}

record(sub, "RCMP:CP07:21:ORDER_ONL") {
  field(DESC, "Rec.Cmpr1")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "RCMP:CP07:21:ORDER_ONT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "RCMP:CP07:21:ORDER_ON")
  field(INPB, "RCMP:CP07:21:ON_CFRM")
  field(INPC, "RCMP:CP07:21:ON_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "RCMP:CP07:21:ORDER_ONT") {
  field(DESC, "Rec.Cmpr1")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "RCMP:CP07:21:ORDER_ONL")
  field(OUT, "RCMP:CP07:21:RQST_ON")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

record(sub, "RCMP:CP07:21:ORDER_OFFL") {
  field(DESC, "Rec.Cmpr1")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "RCMP:CP07:21:ORDER_OFFT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "RCMP:CP07:21:ORDER_OFF")
  field(INPB, "RCMP:CP07:21:OFF_CFRM")
  field(INPC, "RCMP:CP07:21:OFF_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "RCMP:CP07:21:ORDER_OFFT") {
  field(DESC, "Rec.Cmpr1")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(OMSL, "closed_loop")
  field(DOL, "RCMP:CP07:21:ORDER_OFFL")
  field(OUT, "RCMP:CP07:21:RQST_OFF")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(0,416,1.1)
#! Record("RCMP:CP07:21:ORDER_ON",80,378,0,1,"RCMP:CP07:21:ORDER_ON")
#! Field("RCMP:CP07:21:ORDER_ON.VAL",16777215,1,"RCMP:CP07:21:ORDER_ON.VAL")
#! Record("RCMP:CP07:21:ON_CNCL",80,798,0,1,"RCMP:CP07:21:ON_CNCL")
#! Field("RCMP:CP07:21:ON_CNCL.VAL",16777215,1,"RCMP:CP07:21:ON_CNCL.VAL")
#! Record("RCMP:CP07:21:ORDER_OFF",80,1018,0,1,"RCMP:CP07:21:ORDER_OFF")
#! Field("RCMP:CP07:21:ORDER_OFF.VAL",16777215,1,"RCMP:CP07:21:ORDER_OFF.VAL")
#! Record("RCMP:CP07:21:OFF_CNCL",80,1458,0,1,"RCMP:CP07:21:OFF_CNCL")
#! Field("RCMP:CP07:21:OFF_CNCL.VAL",16777215,1,"RCMP:CP07:21:OFF_CNCL.VAL")
#! Record("RCMP:CP07:21:ON_CFRM",80,578,0,1,"RCMP:CP07:21:ON_CFRM")
#! Field("RCMP:CP07:21:ON_CFRM.VAL",16777215,1,"RCMP:CP07:21:ON_CFRM.VAL")
#! Record("RCMP:CP07:21:OFF_CFRM",80,1238,0,1,"RCMP:CP07:21:OFF_CFRM")
#! Field("RCMP:CP07:21:OFF_CFRM.VAL",16777215,1,"RCMP:CP07:21:OFF_CFRM.VAL")
#! Record("RCMP:CP07:21:RQST_ON",960,584,0,1,"RCMP:CP07:21:RQST_ON")
#! Field("RCMP:CP07:21:RQST_ON.VAL",16777215,1,"RCMP:CP07:21:RQST_ON.VAL")
#! Record("RCMP:CP07:21:RQST_OFF",960,1204,0,1,"RCMP:CP07:21:RQST_OFF")
#! Field("RCMP:CP07:21:RQST_OFF.VAL",16777215,1,"RCMP:CP07:21:RQST_OFF.VAL")
#! Record("RCMP:CP07:21:ORDER_ONL",400,524,0,1,"RCMP:CP07:21:ORDER_ONL")
#! Field("RCMP:CP07:21:ORDER_ONL.FLNK",16777215,1,"RCMP:CP07:21:ORDER_ONL.FLNK")
#! Link("RCMP:CP07:21:ORDER_ONL.FLNK","RCMP:CP07:21:ORDER_ONT")
#! Field("RCMP:CP07:21:ORDER_ONL.INPA",16777215,0,"RCMP:CP07:21:ORDER_ONL.INPA")
#! Link("RCMP:CP07:21:ORDER_ONL.INPA","RCMP:CP07:21:ORDER_ON.VAL")
#! Field("RCMP:CP07:21:ORDER_ONL.INPB",16777215,0,"RCMP:CP07:21:ORDER_ONL.INPB")
#! Link("RCMP:CP07:21:ORDER_ONL.INPB","RCMP:CP07:21:ON_CFRM.VAL")
#! Field("RCMP:CP07:21:ORDER_ONL.INPC",16777215,0,"RCMP:CP07:21:ORDER_ONL.INPC")
#! Link("RCMP:CP07:21:ORDER_ONL.INPC","RCMP:CP07:21:ON_CNCL.VAL")
#! Field("RCMP:CP07:21:ORDER_ONL.VAL",16777215,1,"RCMP:CP07:21:ORDER_ONL.VAL")
#! Record("RCMP:CP07:21:ORDER_ONT",700,522,0,0,"RCMP:CP07:21:ORDER_ONT")
#! Field("RCMP:CP07:21:ORDER_ONT.DOL",16777215,0,"RCMP:CP07:21:ORDER_ONT.DOL")
#! Link("RCMP:CP07:21:ORDER_ONT.DOL","RCMP:CP07:21:ORDER_ONL.VAL")
#! Field("RCMP:CP07:21:ORDER_ONT.OUT",16777215,1,"RCMP:CP07:21:ORDER_ONT.OUT")
#! Link("RCMP:CP07:21:ORDER_ONT.OUT","RCMP:CP07:21:RQST_ON.VAL")
#! Record("RCMP:CP07:21:ORDER_OFFL",400,1124,0,1,"RCMP:CP07:21:ORDER_OFFL")
#! Field("RCMP:CP07:21:ORDER_OFFL.FLNK",16777215,1,"RCMP:CP07:21:ORDER_OFFL.FLNK")
#! Link("RCMP:CP07:21:ORDER_OFFL.FLNK","RCMP:CP07:21:ORDER_OFFT")
#! Field("RCMP:CP07:21:ORDER_OFFL.INPA",16777215,0,"RCMP:CP07:21:ORDER_OFFL.INPA")
#! Link("RCMP:CP07:21:ORDER_OFFL.INPA","RCMP:CP07:21:ORDER_OFF.VAL")
#! Field("RCMP:CP07:21:ORDER_OFFL.INPC",16777215,0,"RCMP:CP07:21:ORDER_OFFL.INPC")
#! Link("RCMP:CP07:21:ORDER_OFFL.INPC","RCMP:CP07:21:OFF_CNCL.VAL")
#! Field("RCMP:CP07:21:ORDER_OFFL.INPB",16777215,0,"RCMP:CP07:21:ORDER_OFFL.INPB")
#! Link("RCMP:CP07:21:ORDER_OFFL.INPB","RCMP:CP07:21:OFF_CFRM.VAL")
#! Field("RCMP:CP07:21:ORDER_OFFL.VAL",16777215,1,"RCMP:CP07:21:ORDER_OFFL.VAL")
#! Record("RCMP:CP07:21:ORDER_OFFT",700,1156,0,0,"RCMP:CP07:21:ORDER_OFFT")
#! Field("RCMP:CP07:21:ORDER_OFFT.DOL",16777215,0,"RCMP:CP07:21:ORDER_OFFT.DOL")
#! Link("RCMP:CP07:21:ORDER_OFFT.DOL","RCMP:CP07:21:ORDER_OFFL.VAL")
#! Field("RCMP:CP07:21:ORDER_OFFT.OUT",16777215,1,"RCMP:CP07:21:ORDER_OFFT.OUT")
#! Link("RCMP:CP07:21:ORDER_OFFT.OUT","RCMP:CP07:21:RQST_OFF.VAL")
#! TextBox(TB1,480,360,780,400,0,"Dialog",12,1,16777215,"Turn On and confirm logic\nTurn Off and confirm logic\n",null)
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "RCMP:CP07:22:ORDER_ON") {
  field(DESC, "Rec.Cmpr2 order on")
  field(ZNAM, "not ordered on")
  field(ONAM, "ordered on")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "RCMP:CP07:22:ON_CNCL") {
  field(DESC, "Rec.Cmpr2 Cancel ON order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "RCMP:CP07:22:ORDER_OFF") {
  field(DESC, "Rec.Cmpr2 order off")
  field(ZNAM, "not order off")
  field(ONAM, "order off")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "RCMP:CP07:22:OFF_CNCL") {
  field(DESC, "Rec.Cmpr2 Cancel OFF order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "RCMP:CP07:22:ON_CFRM") {
  field(DESC, "Rec.Cmpr2 confirm ON order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
  field(OMSL, "supervisory")
}

record(bo, "RCMP:CP07:22:OFF_CFRM") {
  field(DESC, "Rec.Cmpr2 confirm OFF order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "RCMP:CP07:22:RQST_ON") {
  field(DESC, "Rec.Cmpr2 Rqst On")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CCMP722_ON B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(SCAN, "1 second")
  field(PINI, "NO")
  field(ASG, "NOWRITE")
  field(HIGH, "0")
  field(OMSL, "supervisory")
}

record(bo, "RCMP:CP07:22:RQST_OFF") {
  field(DESC, "Rec.Cmpr2 Rqst Off")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CCMP722_OF B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(ASG, "NOWRITE")
  field(PINI, "NO")
  field(HIGH, "0")
  field(SCAN, "1 second")
  field(OMSL, "supervisory")
}

record(sub, "RCMP:CP07:22:ORDER_ONL") {
  field(DESC, "Rec.Cmpr2")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "RCMP:CP07:22:ORDER_ONT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "RCMP:CP07:22:ORDER_ON")
  field(INPB, "RCMP:CP07:22:ON_CFRM")
  field(INPC, "RCMP:CP07:22:ON_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "RCMP:CP07:22:ORDER_ONT") {
  field(DESC, "Rec.Cmpr2")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "RCMP:CP07:22:ORDER_ONL")
  field(OUT, "RCMP:CP07:22:RQST_ON")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

record(sub, "RCMP:CP07:22:ORDER_OFFL") {
  field(DESC, "Rec.Cmpr2")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "RCMP:CP07:22:ORDER_OFFT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "RCMP:CP07:22:ORDER_OFF")
  field(INPB, "RCMP:CP07:22:OFF_CFRM")
  field(INPC, "RCMP:CP07:22:OFF_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "RCMP:CP07:22:ORDER_OFFT") {
  field(DESC, "Rec.Cmpr2")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(OMSL, "closed_loop")
  field(DOL, "RCMP:CP07:22:ORDER_OFFL")
  field(OUT, "RCMP:CP07:22:RQST_OFF")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(0,416,1.1)
#! Record("RCMP:CP07:22:ORDER_ON",80,378,0,1,"RCMP:CP07:22:ORDER_ON")
#! Field("RCMP:CP07:22:ORDER_ON.VAL",16777215,1,"RCMP:CP07:22:ORDER_ON.VAL")
#! Record("RCMP:CP07:22:ON_CNCL",80,798,0,1,"RCMP:CP07:22:ON_CNCL")
#! Field("RCMP:CP07:22:ON_CNCL.VAL",16777215,1,"RCMP:CP07:22:ON_CNCL.VAL")
#! Record("RCMP:CP07:22:ORDER_OFF",80,1018,0,1,"RCMP:CP07:22:ORDER_OFF")
#! Field("RCMP:CP07:22:ORDER_OFF.VAL",16777215,1,"RCMP:CP07:22:ORDER_OFF.VAL")
#! Record("RCMP:CP07:22:OFF_CNCL",80,1458,0,1,"RCMP:CP07:22:OFF_CNCL")
#! Field("RCMP:CP07:22:OFF_CNCL.VAL",16777215,1,"RCMP:CP07:22:OFF_CNCL.VAL")
#! Record("RCMP:CP07:22:ON_CFRM",80,578,0,1,"RCMP:CP07:22:ON_CFRM")
#! Field("RCMP:CP07:22:ON_CFRM.VAL",16777215,1,"RCMP:CP07:22:ON_CFRM.VAL")
#! Record("RCMP:CP07:22:OFF_CFRM",80,1238,0,1,"RCMP:CP07:22:OFF_CFRM")
#! Field("RCMP:CP07:22:OFF_CFRM.VAL",16777215,1,"RCMP:CP07:22:OFF_CFRM.VAL")
#! Record("RCMP:CP07:22:RQST_ON",960,584,0,1,"RCMP:CP07:22:RQST_ON")
#! Field("RCMP:CP07:22:RQST_ON.VAL",16777215,1,"RCMP:CP07:22:RQST_ON.VAL")
#! Record("RCMP:CP07:22:RQST_OFF",960,1204,0,1,"RCMP:CP07:22:RQST_OFF")
#! Field("RCMP:CP07:22:RQST_OFF.VAL",16777215,1,"RCMP:CP07:22:RQST_OFF.VAL")
#! Record("RCMP:CP07:22:ORDER_ONL",400,524,0,1,"RCMP:CP07:22:ORDER_ONL")
#! Field("RCMP:CP07:22:ORDER_ONL.FLNK",16777215,1,"RCMP:CP07:22:ORDER_ONL.FLNK")
#! Link("RCMP:CP07:22:ORDER_ONL.FLNK","RCMP:CP07:22:ORDER_ONT")
#! Field("RCMP:CP07:22:ORDER_ONL.INPA",16777215,0,"RCMP:CP07:22:ORDER_ONL.INPA")
#! Link("RCMP:CP07:22:ORDER_ONL.INPA","RCMP:CP07:22:ORDER_ON.VAL")
#! Field("RCMP:CP07:22:ORDER_ONL.INPB",16777215,0,"RCMP:CP07:22:ORDER_ONL.INPB")
#! Link("RCMP:CP07:22:ORDER_ONL.INPB","RCMP:CP07:22:ON_CFRM.VAL")
#! Field("RCMP:CP07:22:ORDER_ONL.INPC",16777215,0,"RCMP:CP07:22:ORDER_ONL.INPC")
#! Link("RCMP:CP07:22:ORDER_ONL.INPC","RCMP:CP07:22:ON_CNCL.VAL")
#! Field("RCMP:CP07:22:ORDER_ONL.VAL",16777215,1,"RCMP:CP07:22:ORDER_ONL.VAL")
#! Record("RCMP:CP07:22:ORDER_ONT",700,522,0,0,"RCMP:CP07:22:ORDER_ONT")
#! Field("RCMP:CP07:22:ORDER_ONT.DOL",16777215,0,"RCMP:CP07:22:ORDER_ONT.DOL")
#! Link("RCMP:CP07:22:ORDER_ONT.DOL","RCMP:CP07:22:ORDER_ONL.VAL")
#! Field("RCMP:CP07:22:ORDER_ONT.OUT",16777215,1,"RCMP:CP07:22:ORDER_ONT.OUT")
#! Link("RCMP:CP07:22:ORDER_ONT.OUT","RCMP:CP07:22:RQST_ON.VAL")
#! Record("RCMP:CP07:22:ORDER_OFFL",400,1124,0,1,"RCMP:CP07:22:ORDER_OFFL")
#! Field("RCMP:CP07:22:ORDER_OFFL.FLNK",16777215,1,"RCMP:CP07:22:ORDER_OFFL.FLNK")
#! Link("RCMP:CP07:22:ORDER_OFFL.FLNK","RCMP:CP07:22:ORDER_OFFT")
#! Field("RCMP:CP07:22:ORDER_OFFL.INPA",16777215,0,"RCMP:CP07:22:ORDER_OFFL.INPA")
#! Link("RCMP:CP07:22:ORDER_OFFL.INPA","RCMP:CP07:22:ORDER_OFF.VAL")
#! Field("RCMP:CP07:22:ORDER_OFFL.INPC",16777215,0,"RCMP:CP07:22:ORDER_OFFL.INPC")
#! Link("RCMP:CP07:22:ORDER_OFFL.INPC","RCMP:CP07:22:OFF_CNCL.VAL")
#! Field("RCMP:CP07:22:ORDER_OFFL.INPB",16777215,0,"RCMP:CP07:22:ORDER_OFFL.INPB")
#! Link("RCMP:CP07:22:ORDER_OFFL.INPB","RCMP:CP07:22:OFF_CFRM.VAL")
#! Field("RCMP:CP07:22:ORDER_OFFL.VAL",16777215,1,"RCMP:CP07:22:ORDER_OFFL.VAL")
#! Record("RCMP:CP07:22:ORDER_OFFT",700,1156,0,0,"RCMP:CP07:22:ORDER_OFFT")
#! Field("RCMP:CP07:22:ORDER_OFFT.DOL",16777215,0,"RCMP:CP07:22:ORDER_OFFT.DOL")
#! Link("RCMP:CP07:22:ORDER_OFFT.DOL","RCMP:CP07:22:ORDER_OFFL.VAL")
#! Field("RCMP:CP07:22:ORDER_OFFT.OUT",16777215,1,"RCMP:CP07:22:ORDER_OFFT.OUT")
#! Link("RCMP:CP07:22:ORDER_OFFT.OUT","RCMP:CP07:22:RQST_OFF.VAL")
#! TextBox(TB1,480,360,780,400,0,"Dialog",12,1,16777215,"Turn On and confirm logic\nTurn Off and confirm logic\n",null)
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "CVP:CP08:4100:ORDER_ON") {
  field(DESC, "GVPmp1 order on")
  field(ZNAM, "not ordered on")
  field(ONAM, "ordered on")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CVP:CP08:4100:ON_CNCL") {
  field(DESC, "GVPmp1 Cancel ON order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CVP:CP08:4100:ORDER_OFF") {
  field(DESC, "GVPmp1 order off")
  field(ZNAM, "not order off")
  field(ONAM, "order off")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CVP:CP08:4100:OFF_CNCL") {
  field(DESC, "GVPmp1 Cancel OFF order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CVP:CP08:4100:ON_CFRM") {
  field(DESC, "GVPmp1 confirm ON order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
  field(OMSL, "supervisory")
}

record(bo, "CVP:CP08:4100:OFF_CFRM") {
  field(DESC, "GVPmp1 confirm OFF order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CVP:CP08:4100:RQST_ON") {
  field(DESC, "GVPmp1 Rqst On")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CVP84100_CMD.START")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(SCAN, "1 second")
  field(PINI, "NO")
  field(ASG, "NOWRITE")
  field(HIGH, "0")
  field(OMSL, "supervisory")
}

record(bo, "CVP:CP08:4100:RQST_OFF") {
  field(DESC, "GVPmp1 Rqst Off")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CVP84100_CMD.STOP")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(ASG, "NOWRITE")
  field(PINI, "NO")
  field(HIGH, "0")
  field(SCAN, "1 second")
  field(OMSL, "supervisory")
}

record(sub, "CVP:CP08:4100:ORDER_ONL") {
  field(DESC, "GVPmp1")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CVP:CP08:4100:ORDER_ONT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CVP:CP08:4100:ORDER_ON")
  field(INPB, "CVP:CP08:4100:ON_CFRM")
  field(INPC, "CVP:CP08:4100:ON_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CVP:CP08:4100:ORDER_ONT") {
  field(DESC, "GVPmp1")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "CVP:CP08:4100:ORDER_ONL")
  field(OUT, "CVP:CP08:4100:RQST_ON")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

record(sub, "CVP:CP08:4100:ORDER_OFFL") {
  field(DESC, "GVPmp1")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CVP:CP08:4100:ORDER_OFFT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CVP:CP08:4100:ORDER_OFF")
  field(INPB, "CVP:CP08:4100:OFF_CFRM")
  field(INPC, "CVP:CP08:4100:OFF_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CVP:CP08:4100:ORDER_OFFT") {
  field(DESC, "GVPmp1")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(OMSL, "closed_loop")
  field(DOL, "CVP:CP08:4100:ORDER_OFFL")
  field(OUT, "CVP:CP08:4100:RQST_OFF")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(0,416,1.1)
#! Record("CVP:CP08:4100:ORDER_ON",80,378,0,1,"CVP:CP08:4100:ORDER_ON")
#! Field("CVP:CP08:4100:ORDER_ON.VAL",16777215,1,"CVP:CP08:4100:ORDER_ON.VAL")
#! Record("CVP:CP08:4100:ON_CNCL",80,798,0,1,"CVP:CP08:4100:ON_CNCL")
#! Field("CVP:CP08:4100:ON_CNCL.VAL",16777215,1,"CVP:CP08:4100:ON_CNCL.VAL")
#! Record("CVP:CP08:4100:ORDER_OFF",80,1018,0,1,"CVP:CP08:4100:ORDER_OFF")
#! Field("CVP:CP08:4100:ORDER_OFF.VAL",16777215,1,"CVP:CP08:4100:ORDER_OFF.VAL")
#! Record("CVP:CP08:4100:OFF_CNCL",80,1458,0,1,"CVP:CP08:4100:OFF_CNCL")
#! Field("CVP:CP08:4100:OFF_CNCL.VAL",16777215,1,"CVP:CP08:4100:OFF_CNCL.VAL")
#! Record("CVP:CP08:4100:ON_CFRM",80,578,0,1,"CVP:CP08:4100:ON_CFRM")
#! Field("CVP:CP08:4100:ON_CFRM.VAL",16777215,1,"CVP:CP08:4100:ON_CFRM.VAL")
#! Record("CVP:CP08:4100:OFF_CFRM",80,1238,0,1,"CVP:CP08:4100:OFF_CFRM")
#! Field("CVP:CP08:4100:OFF_CFRM.VAL",16777215,1,"CVP:CP08:4100:OFF_CFRM.VAL")
#! Record("CVP:CP08:4100:RQST_ON",960,584,0,1,"CVP:CP08:4100:RQST_ON")
#! Field("CVP:CP08:4100:RQST_ON.VAL",16777215,1,"CVP:CP08:4100:RQST_ON.VAL")
#! Record("CVP:CP08:4100:RQST_OFF",960,1204,0,1,"CVP:CP08:4100:RQST_OFF")
#! Field("CVP:CP08:4100:RQST_OFF.VAL",16777215,1,"CVP:CP08:4100:RQST_OFF.VAL")
#! Record("CVP:CP08:4100:ORDER_ONL",400,524,0,1,"CVP:CP08:4100:ORDER_ONL")
#! Field("CVP:CP08:4100:ORDER_ONL.FLNK",16777215,1,"CVP:CP08:4100:ORDER_ONL.FLNK")
#! Link("CVP:CP08:4100:ORDER_ONL.FLNK","CVP:CP08:4100:ORDER_ONT")
#! Field("CVP:CP08:4100:ORDER_ONL.INPA",16777215,0,"CVP:CP08:4100:ORDER_ONL.INPA")
#! Link("CVP:CP08:4100:ORDER_ONL.INPA","CVP:CP08:4100:ORDER_ON.VAL")
#! Field("CVP:CP08:4100:ORDER_ONL.INPB",16777215,0,"CVP:CP08:4100:ORDER_ONL.INPB")
#! Link("CVP:CP08:4100:ORDER_ONL.INPB","CVP:CP08:4100:ON_CFRM.VAL")
#! Field("CVP:CP08:4100:ORDER_ONL.INPC",16777215,0,"CVP:CP08:4100:ORDER_ONL.INPC")
#! Link("CVP:CP08:4100:ORDER_ONL.INPC","CVP:CP08:4100:ON_CNCL.VAL")
#! Field("CVP:CP08:4100:ORDER_ONL.VAL",16777215,1,"CVP:CP08:4100:ORDER_ONL.VAL")
#! Record("CVP:CP08:4100:ORDER_ONT",700,522,0,0,"CVP:CP08:4100:ORDER_ONT")
#! Field("CVP:CP08:4100:ORDER_ONT.DOL",16777215,0,"CVP:CP08:4100:ORDER_ONT.DOL")
#! Link("CVP:CP08:4100:ORDER_ONT.DOL","CVP:CP08:4100:ORDER_ONL.VAL")
#! Field("CVP:CP08:4100:ORDER_ONT.OUT",16777215,1,"CVP:CP08:4100:ORDER_ONT.OUT")
#! Link("CVP:CP08:4100:ORDER_ONT.OUT","CVP:CP08:4100:RQST_ON.VAL")
#! Record("CVP:CP08:4100:ORDER_OFFL",400,1124,0,1,"CVP:CP08:4100:ORDER_OFFL")
#! Field("CVP:CP08:4100:ORDER_OFFL.FLNK",16777215,1,"CVP:CP08:4100:ORDER_OFFL.FLNK")
#! Link("CVP:CP08:4100:ORDER_OFFL.FLNK","CVP:CP08:4100:ORDER_OFFT")
#! Field("CVP:CP08:4100:ORDER_OFFL.INPA",16777215,0,"CVP:CP08:4100:ORDER_OFFL.INPA")
#! Link("CVP:CP08:4100:ORDER_OFFL.INPA","CVP:CP08:4100:ORDER_OFF.VAL")
#! Field("CVP:CP08:4100:ORDER_OFFL.INPC",16777215,0,"CVP:CP08:4100:ORDER_OFFL.INPC")
#! Link("CVP:CP08:4100:ORDER_OFFL.INPC","CVP:CP08:4100:OFF_CNCL.VAL")
#! Field("CVP:CP08:4100:ORDER_OFFL.INPB",16777215,0,"CVP:CP08:4100:ORDER_OFFL.INPB")
#! Link("CVP:CP08:4100:ORDER_OFFL.INPB","CVP:CP08:4100:OFF_CFRM.VAL")
#! Field("CVP:CP08:4100:ORDER_OFFL.VAL",16777215,1,"CVP:CP08:4100:ORDER_OFFL.VAL")
#! Record("CVP:CP08:4100:ORDER_OFFT",700,1156,0,0,"CVP:CP08:4100:ORDER_OFFT")
#! Field("CVP:CP08:4100:ORDER_OFFT.DOL",16777215,0,"CVP:CP08:4100:ORDER_OFFT.DOL")
#! Link("CVP:CP08:4100:ORDER_OFFT.DOL","CVP:CP08:4100:ORDER_OFFL.VAL")
#! Field("CVP:CP08:4100:ORDER_OFFT.OUT",16777215,1,"CVP:CP08:4100:ORDER_OFFT.OUT")
#! Link("CVP:CP08:4100:ORDER_OFFT.OUT","CVP:CP08:4100:RQST_OFF.VAL")
#! TextBox(TB1,480,360,780,400,0,"Dialog",12,1,16777215,"Turn On and confirm logic\nTurn Off and confirm logic\n",null)
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "CVP:CP08:4200:ORDER_ON") {
  field(DESC, "GVPmp2 order on")
  field(ZNAM, "not ordered on")
  field(ONAM, "ordered on")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CVP:CP08:4200:ON_CNCL") {
  field(DESC, "GVPmp2 Cancel ON order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CVP:CP08:4200:ORDER_OFF") {
  field(DESC, "GVPmp2 order off")
  field(ZNAM, "not order off")
  field(ONAM, "order off")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CVP:CP08:4200:OFF_CNCL") {
  field(DESC, "GVPmp2 Cancel OFF order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CVP:CP08:4200:ON_CFRM") {
  field(DESC, "GVPmp2 confirm ON order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
  field(OMSL, "supervisory")
}

record(bo, "CVP:CP08:4200:OFF_CFRM") {
  field(DESC, "GVPmp2 confirm OFF order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CVP:CP08:4200:RQST_ON") {
  field(DESC, "GVPmp2 Rqst On")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CVP84200_CMD.START")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(SCAN, "1 second")
  field(PINI, "NO")
  field(ASG, "NOWRITE")
  field(HIGH, "0")
  field(OMSL, "supervisory")
}

record(bo, "CVP:CP08:4200:RQST_OFF") {
  field(DESC, "GVPmp2 Rqst Off")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CVP84200_CMD.STOP")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(ASG, "NOWRITE")
  field(PINI, "NO")
  field(HIGH, "0")
  field(SCAN, "1 second")
  field(OMSL, "supervisory")
}

record(sub, "CVP:CP08:4200:ORDER_ONL") {
  field(DESC, "GVPmp2")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CVP:CP08:4200:ORDER_ONT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CVP:CP08:4200:ORDER_ON")
  field(INPB, "CVP:CP08:4200:ON_CFRM")
  field(INPC, "CVP:CP08:4200:ON_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CVP:CP08:4200:ORDER_ONT") {
  field(DESC, "GVPmp2")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "CVP:CP08:4200:ORDER_ONL")
  field(OUT, "CVP:CP08:4200:RQST_ON")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

record(sub, "CVP:CP08:4200:ORDER_OFFL") {
  field(DESC, "GVPmp2")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CVP:CP08:4200:ORDER_OFFT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CVP:CP08:4200:ORDER_OFF")
  field(INPB, "CVP:CP08:4200:OFF_CFRM")
  field(INPC, "CVP:CP08:4200:OFF_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CVP:CP08:4200:ORDER_OFFT") {
  field(DESC, "GVPmp2")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(OMSL, "closed_loop")
  field(DOL, "CVP:CP08:4200:ORDER_OFFL")
  field(OUT, "CVP:CP08:4200:RQST_OFF")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(0,416,1.1)
#! Record("CVP:CP08:4200:ORDER_ON",80,378,0,1,"CVP:CP08:4200:ORDER_ON")
#! Field("CVP:CP08:4200:ORDER_ON.VAL",16777215,1,"CVP:CP08:4200:ORDER_ON.VAL")
#! Record("CVP:CP08:4200:ON_CNCL",80,798,0,1,"CVP:CP08:4200:ON_CNCL")
#! Field("CVP:CP08:4200:ON_CNCL.VAL",16777215,1,"CVP:CP08:4200:ON_CNCL.VAL")
#! Record("CVP:CP08:4200:ORDER_OFF",80,1018,0,1,"CVP:CP08:4200:ORDER_OFF")
#! Field("CVP:CP08:4200:ORDER_OFF.VAL",16777215,1,"CVP:CP08:4200:ORDER_OFF.VAL")
#! Record("CVP:CP08:4200:OFF_CNCL",80,1458,0,1,"CVP:CP08:4200:OFF_CNCL")
#! Field("CVP:CP08:4200:OFF_CNCL.VAL",16777215,1,"CVP:CP08:4200:OFF_CNCL.VAL")
#! Record("CVP:CP08:4200:ON_CFRM",80,578,0,1,"CVP:CP08:4200:ON_CFRM")
#! Field("CVP:CP08:4200:ON_CFRM.VAL",16777215,1,"CVP:CP08:4200:ON_CFRM.VAL")
#! Record("CVP:CP08:4200:OFF_CFRM",80,1238,0,1,"CVP:CP08:4200:OFF_CFRM")
#! Field("CVP:CP08:4200:OFF_CFRM.VAL",16777215,1,"CVP:CP08:4200:OFF_CFRM.VAL")
#! Record("CVP:CP08:4200:RQST_ON",960,584,0,1,"CVP:CP08:4200:RQST_ON")
#! Field("CVP:CP08:4200:RQST_ON.VAL",16777215,1,"CVP:CP08:4200:RQST_ON.VAL")
#! Record("CVP:CP08:4200:RQST_OFF",960,1204,0,1,"CVP:CP08:4200:RQST_OFF")
#! Field("CVP:CP08:4200:RQST_OFF.VAL",16777215,1,"CVP:CP08:4200:RQST_OFF.VAL")
#! Record("CVP:CP08:4200:ORDER_ONL",400,524,0,1,"CVP:CP08:4200:ORDER_ONL")
#! Field("CVP:CP08:4200:ORDER_ONL.FLNK",16777215,1,"CVP:CP08:4200:ORDER_ONL.FLNK")
#! Link("CVP:CP08:4200:ORDER_ONL.FLNK","CVP:CP08:4200:ORDER_ONT")
#! Field("CVP:CP08:4200:ORDER_ONL.INPA",16777215,0,"CVP:CP08:4200:ORDER_ONL.INPA")
#! Link("CVP:CP08:4200:ORDER_ONL.INPA","CVP:CP08:4200:ORDER_ON.VAL")
#! Field("CVP:CP08:4200:ORDER_ONL.INPB",16777215,0,"CVP:CP08:4200:ORDER_ONL.INPB")
#! Link("CVP:CP08:4200:ORDER_ONL.INPB","CVP:CP08:4200:ON_CFRM.VAL")
#! Field("CVP:CP08:4200:ORDER_ONL.INPC",16777215,0,"CVP:CP08:4200:ORDER_ONL.INPC")
#! Link("CVP:CP08:4200:ORDER_ONL.INPC","CVP:CP08:4200:ON_CNCL.VAL")
#! Field("CVP:CP08:4200:ORDER_ONL.VAL",16777215,1,"CVP:CP08:4200:ORDER_ONL.VAL")
#! Record("CVP:CP08:4200:ORDER_ONT",700,522,0,0,"CVP:CP08:4200:ORDER_ONT")
#! Field("CVP:CP08:4200:ORDER_ONT.DOL",16777215,0,"CVP:CP08:4200:ORDER_ONT.DOL")
#! Link("CVP:CP08:4200:ORDER_ONT.DOL","CVP:CP08:4200:ORDER_ONL.VAL")
#! Field("CVP:CP08:4200:ORDER_ONT.OUT",16777215,1,"CVP:CP08:4200:ORDER_ONT.OUT")
#! Link("CVP:CP08:4200:ORDER_ONT.OUT","CVP:CP08:4200:RQST_ON.VAL")
#! Record("CVP:CP08:4200:ORDER_OFFL",400,1124,0,1,"CVP:CP08:4200:ORDER_OFFL")
#! Field("CVP:CP08:4200:ORDER_OFFL.FLNK",16777215,1,"CVP:CP08:4200:ORDER_OFFL.FLNK")
#! Link("CVP:CP08:4200:ORDER_OFFL.FLNK","CVP:CP08:4200:ORDER_OFFT")
#! Field("CVP:CP08:4200:ORDER_OFFL.INPA",16777215,0,"CVP:CP08:4200:ORDER_OFFL.INPA")
#! Link("CVP:CP08:4200:ORDER_OFFL.INPA","CVP:CP08:4200:ORDER_OFF.VAL")
#! Field("CVP:CP08:4200:ORDER_OFFL.INPC",16777215,0,"CVP:CP08:4200:ORDER_OFFL.INPC")
#! Link("CVP:CP08:4200:ORDER_OFFL.INPC","CVP:CP08:4200:OFF_CNCL.VAL")
#! Field("CVP:CP08:4200:ORDER_OFFL.INPB",16777215,0,"CVP:CP08:4200:ORDER_OFFL.INPB")
#! Link("CVP:CP08:4200:ORDER_OFFL.INPB","CVP:CP08:4200:OFF_CFRM.VAL")
#! Field("CVP:CP08:4200:ORDER_OFFL.VAL",16777215,1,"CVP:CP08:4200:ORDER_OFFL.VAL")
#! Record("CVP:CP08:4200:ORDER_OFFT",700,1156,0,0,"CVP:CP08:4200:ORDER_OFFT")
#! Field("CVP:CP08:4200:ORDER_OFFT.DOL",16777215,0,"CVP:CP08:4200:ORDER_OFFT.DOL")
#! Link("CVP:CP08:4200:ORDER_OFFT.DOL","CVP:CP08:4200:ORDER_OFFL.VAL")
#! Field("CVP:CP08:4200:ORDER_OFFT.OUT",16777215,1,"CVP:CP08:4200:ORDER_OFFT.OUT")
#! Link("CVP:CP08:4200:ORDER_OFFT.OUT","CVP:CP08:4200:RQST_OFF.VAL")
#! TextBox(TB1,480,360,780,400,0,"Dialog",12,1,16777215,"Turn On and confirm logic\nTurn Off and confirm logic\n",null)
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "CSV:CP08:4110:ORDER_ON") {
  field(DESC, "GVInletV1 order on")
  field(ZNAM, "not ordered on")
  field(ONAM, "ordered on")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4110:ON_CNCL") {
  field(DESC, "GVInletV1 Cancel ON order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4110:ORDER_OFF") {
  field(DESC, "GVInletV1 order off")
  field(ZNAM, "not order off")
  field(ONAM, "order off")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4110:OFF_CNCL") {
  field(DESC, "GVInletV1 Cancel OFF order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4110:ON_CFRM") {
  field(DESC, "GVInletV1 confirm ON order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
  field(OMSL, "supervisory")
}

record(bo, "CSV:CP08:4110:OFF_CFRM") {
  field(DESC, "GVInletV1 confirm OFF order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4110:RQST_ON") {
  field(DESC, "GVInletV1 Rqst On")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CSV84110.EN B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(SCAN, "1 second")
  field(PINI, "NO")
  field(ASG, "NOWRITE")
  field(HIGH, "0")
  field(OMSL, "supervisory")
}

record(bo, "CSV:CP08:4110:RQST_OFF") {
  field(DESC, "GVInletV1 Rqst Off")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CSV84110.DIS B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(ASG, "NOWRITE")
  field(PINI, "NO")
  field(HIGH, "0")
  field(SCAN, "1 second")
  field(OMSL, "supervisory")
}

record(sub, "CSV:CP08:4110:ORDER_ONL") {
  field(DESC, "GVInletV1")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CSV:CP08:4110:ORDER_ONT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CSV:CP08:4110:ORDER_ON")
  field(INPB, "CSV:CP08:4110:ON_CFRM")
  field(INPC, "CSV:CP08:4110:ON_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CSV:CP08:4110:ORDER_ONT") {
  field(DESC, "GVInletV1")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "CSV:CP08:4110:ORDER_ONL")
  field(OUT, "CSV:CP08:4110:RQST_ON")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

record(sub, "CSV:CP08:4110:ORDER_OFFL") {
  field(DESC, "GVInletV1")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CSV:CP08:4110:ORDER_OFFT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CSV:CP08:4110:ORDER_OFF")
  field(INPB, "CSV:CP08:4110:OFF_CFRM")
  field(INPC, "CSV:CP08:4110:OFF_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CSV:CP08:4110:ORDER_OFFT") {
  field(DESC, "GVInletV1")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(OMSL, "closed_loop")
  field(DOL, "CSV:CP08:4110:ORDER_OFFL")
  field(OUT, "CSV:CP08:4110:RQST_OFF")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(0,416,1.1)
#! Record("CSV:CP08:4110:ORDER_ON",80,378,0,1,"CSV:CP08:4110:ORDER_ON")
#! Field("CSV:CP08:4110:ORDER_ON.VAL",16777215,1,"CSV:CP08:4110:ORDER_ON.VAL")
#! Record("CSV:CP08:4110:ON_CNCL",80,798,0,1,"CSV:CP08:4110:ON_CNCL")
#! Field("CSV:CP08:4110:ON_CNCL.VAL",16777215,1,"CSV:CP08:4110:ON_CNCL.VAL")
#! Record("CSV:CP08:4110:ORDER_OFF",80,1018,0,1,"CSV:CP08:4110:ORDER_OFF")
#! Field("CSV:CP08:4110:ORDER_OFF.VAL",16777215,1,"CSV:CP08:4110:ORDER_OFF.VAL")
#! Record("CSV:CP08:4110:OFF_CNCL",80,1458,0,1,"CSV:CP08:4110:OFF_CNCL")
#! Field("CSV:CP08:4110:OFF_CNCL.VAL",16777215,1,"CSV:CP08:4110:OFF_CNCL.VAL")
#! Record("CSV:CP08:4110:ON_CFRM",80,578,0,1,"CSV:CP08:4110:ON_CFRM")
#! Field("CSV:CP08:4110:ON_CFRM.VAL",16777215,1,"CSV:CP08:4110:ON_CFRM.VAL")
#! Record("CSV:CP08:4110:OFF_CFRM",80,1238,0,1,"CSV:CP08:4110:OFF_CFRM")
#! Field("CSV:CP08:4110:OFF_CFRM.VAL",16777215,1,"CSV:CP08:4110:OFF_CFRM.VAL")
#! Record("CSV:CP08:4110:RQST_ON",960,584,0,1,"CSV:CP08:4110:RQST_ON")
#! Field("CSV:CP08:4110:RQST_ON.VAL",16777215,1,"CSV:CP08:4110:RQST_ON.VAL")
#! Record("CSV:CP08:4110:RQST_OFF",960,1204,0,1,"CSV:CP08:4110:RQST_OFF")
#! Field("CSV:CP08:4110:RQST_OFF.VAL",16777215,1,"CSV:CP08:4110:RQST_OFF.VAL")
#! Record("CSV:CP08:4110:ORDER_ONL",400,524,0,1,"CSV:CP08:4110:ORDER_ONL")
#! Field("CSV:CP08:4110:ORDER_ONL.FLNK",16777215,1,"CSV:CP08:4110:ORDER_ONL.FLNK")
#! Link("CSV:CP08:4110:ORDER_ONL.FLNK","CSV:CP08:4110:ORDER_ONT")
#! Field("CSV:CP08:4110:ORDER_ONL.INPA",16777215,0,"CSV:CP08:4110:ORDER_ONL.INPA")
#! Link("CSV:CP08:4110:ORDER_ONL.INPA","CSV:CP08:4110:ORDER_ON.VAL")
#! Field("CSV:CP08:4110:ORDER_ONL.INPB",16777215,0,"CSV:CP08:4110:ORDER_ONL.INPB")
#! Link("CSV:CP08:4110:ORDER_ONL.INPB","CSV:CP08:4110:ON_CFRM.VAL")
#! Field("CSV:CP08:4110:ORDER_ONL.INPC",16777215,0,"CSV:CP08:4110:ORDER_ONL.INPC")
#! Link("CSV:CP08:4110:ORDER_ONL.INPC","CSV:CP08:4110:ON_CNCL.VAL")
#! Field("CSV:CP08:4110:ORDER_ONL.VAL",16777215,1,"CSV:CP08:4110:ORDER_ONL.VAL")
#! Record("CSV:CP08:4110:ORDER_ONT",700,522,0,0,"CSV:CP08:4110:ORDER_ONT")
#! Field("CSV:CP08:4110:ORDER_ONT.DOL",16777215,0,"CSV:CP08:4110:ORDER_ONT.DOL")
#! Link("CSV:CP08:4110:ORDER_ONT.DOL","CSV:CP08:4110:ORDER_ONL.VAL")
#! Field("CSV:CP08:4110:ORDER_ONT.OUT",16777215,1,"CSV:CP08:4110:ORDER_ONT.OUT")
#! Link("CSV:CP08:4110:ORDER_ONT.OUT","CSV:CP08:4110:RQST_ON.VAL")
#! Record("CSV:CP08:4110:ORDER_OFFL",400,1124,0,1,"CSV:CP08:4110:ORDER_OFFL")
#! Field("CSV:CP08:4110:ORDER_OFFL.FLNK",16777215,1,"CSV:CP08:4110:ORDER_OFFL.FLNK")
#! Link("CSV:CP08:4110:ORDER_OFFL.FLNK","CSV:CP08:4110:ORDER_OFFT")
#! Field("CSV:CP08:4110:ORDER_OFFL.INPA",16777215,0,"CSV:CP08:4110:ORDER_OFFL.INPA")
#! Link("CSV:CP08:4110:ORDER_OFFL.INPA","CSV:CP08:4110:ORDER_OFF.VAL")
#! Field("CSV:CP08:4110:ORDER_OFFL.INPC",16777215,0,"CSV:CP08:4110:ORDER_OFFL.INPC")
#! Link("CSV:CP08:4110:ORDER_OFFL.INPC","CSV:CP08:4110:OFF_CNCL.VAL")
#! Field("CSV:CP08:4110:ORDER_OFFL.INPB",16777215,0,"CSV:CP08:4110:ORDER_OFFL.INPB")
#! Link("CSV:CP08:4110:ORDER_OFFL.INPB","CSV:CP08:4110:OFF_CFRM.VAL")
#! Field("CSV:CP08:4110:ORDER_OFFL.VAL",16777215,1,"CSV:CP08:4110:ORDER_OFFL.VAL")
#! Record("CSV:CP08:4110:ORDER_OFFT",700,1156,0,0,"CSV:CP08:4110:ORDER_OFFT")
#! Field("CSV:CP08:4110:ORDER_OFFT.DOL",16777215,0,"CSV:CP08:4110:ORDER_OFFT.DOL")
#! Link("CSV:CP08:4110:ORDER_OFFT.DOL","CSV:CP08:4110:ORDER_OFFL.VAL")
#! Field("CSV:CP08:4110:ORDER_OFFT.OUT",16777215,1,"CSV:CP08:4110:ORDER_OFFT.OUT")
#! Link("CSV:CP08:4110:ORDER_OFFT.OUT","CSV:CP08:4110:RQST_OFF.VAL")
#! TextBox(TB1,480,360,780,400,0,"Dialog",12,1,16777215,"Turn On and confirm logic\nTurn Off and confirm logic\n",null)
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "CSV:CP08:4210:ORDER_ON") {
  field(DESC, "GVInletV2 order on")
  field(ZNAM, "not ordered on")
  field(ONAM, "ordered on")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4210:ON_CNCL") {
  field(DESC, "GVInletV2 Cancel ON order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4210:ORDER_OFF") {
  field(DESC, "GVInletV2 order off")
  field(ZNAM, "not order off")
  field(ONAM, "order off")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4210:OFF_CNCL") {
  field(DESC, "GVInletV2 Cancel OFF order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4210:ON_CFRM") {
  field(DESC, "GVInletV2 confirm ON order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
  field(OMSL, "supervisory")
}

record(bo, "CSV:CP08:4210:OFF_CFRM") {
  field(DESC, "GVInletV2 confirm OFF order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4210:RQST_ON") {
  field(DESC, "GVInletV2 Rqst On")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CSV84210.EN B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(SCAN, "1 second")
  field(PINI, "NO")
  field(ASG, "NOWRITE")
  field(HIGH, "0")
  field(OMSL, "supervisory")
}

record(bo, "CSV:CP08:4210:RQST_OFF") {
  field(DESC, "GVInletV2 Rqst Off")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CSV84210.DIS B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(ASG, "NOWRITE")
  field(PINI, "NO")
  field(HIGH, "0")
  field(SCAN, "1 second")
  field(OMSL, "supervisory")
}

record(sub, "CSV:CP08:4210:ORDER_ONL") {
  field(DESC, "GVInletV2")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CSV:CP08:4210:ORDER_ONT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CSV:CP08:4210:ORDER_ON")
  field(INPB, "CSV:CP08:4210:ON_CFRM")
  field(INPC, "CSV:CP08:4210:ON_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CSV:CP08:4210:ORDER_ONT") {
  field(DESC, "GVInletV2")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "CSV:CP08:4210:ORDER_ONL")
  field(OUT, "CSV:CP08:4210:RQST_ON")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

record(sub, "CSV:CP08:4210:ORDER_OFFL") {
  field(DESC, "GVInletV2")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CSV:CP08:4210:ORDER_OFFT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CSV:CP08:4210:ORDER_OFF")
  field(INPB, "CSV:CP08:4210:OFF_CFRM")
  field(INPC, "CSV:CP08:4210:OFF_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CSV:CP08:4210:ORDER_OFFT") {
  field(DESC, "GVInletV2")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(OMSL, "closed_loop")
  field(DOL, "CSV:CP08:4210:ORDER_OFFL")
  field(OUT, "CSV:CP08:4210:RQST_OFF")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(0,416,1.1)
#! Record("CSV:CP08:4210:ORDER_ON",80,378,0,1,"CSV:CP08:4210:ORDER_ON")
#! Field("CSV:CP08:4210:ORDER_ON.VAL",16777215,1,"CSV:CP08:4210:ORDER_ON.VAL")
#! Record("CSV:CP08:4210:ON_CNCL",80,798,0,1,"CSV:CP08:4210:ON_CNCL")
#! Field("CSV:CP08:4210:ON_CNCL.VAL",16777215,1,"CSV:CP08:4210:ON_CNCL.VAL")
#! Record("CSV:CP08:4210:ORDER_OFF",80,1018,0,1,"CSV:CP08:4210:ORDER_OFF")
#! Field("CSV:CP08:4210:ORDER_OFF.VAL",16777215,1,"CSV:CP08:4210:ORDER_OFF.VAL")
#! Record("CSV:CP08:4210:OFF_CNCL",80,1458,0,1,"CSV:CP08:4210:OFF_CNCL")
#! Field("CSV:CP08:4210:OFF_CNCL.VAL",16777215,1,"CSV:CP08:4210:OFF_CNCL.VAL")
#! Record("CSV:CP08:4210:ON_CFRM",80,578,0,1,"CSV:CP08:4210:ON_CFRM")
#! Field("CSV:CP08:4210:ON_CFRM.VAL",16777215,1,"CSV:CP08:4210:ON_CFRM.VAL")
#! Record("CSV:CP08:4210:OFF_CFRM",80,1238,0,1,"CSV:CP08:4210:OFF_CFRM")
#! Field("CSV:CP08:4210:OFF_CFRM.VAL",16777215,1,"CSV:CP08:4210:OFF_CFRM.VAL")
#! Record("CSV:CP08:4210:RQST_ON",960,584,0,1,"CSV:CP08:4210:RQST_ON")
#! Field("CSV:CP08:4210:RQST_ON.VAL",16777215,1,"CSV:CP08:4210:RQST_ON.VAL")
#! Record("CSV:CP08:4210:RQST_OFF",960,1204,0,1,"CSV:CP08:4210:RQST_OFF")
#! Field("CSV:CP08:4210:RQST_OFF.VAL",16777215,1,"CSV:CP08:4210:RQST_OFF.VAL")
#! Record("CSV:CP08:4210:ORDER_ONL",400,524,0,1,"CSV:CP08:4210:ORDER_ONL")
#! Field("CSV:CP08:4210:ORDER_ONL.FLNK",16777215,1,"CSV:CP08:4210:ORDER_ONL.FLNK")
#! Link("CSV:CP08:4210:ORDER_ONL.FLNK","CSV:CP08:4210:ORDER_ONT")
#! Field("CSV:CP08:4210:ORDER_ONL.INPA",16777215,0,"CSV:CP08:4210:ORDER_ONL.INPA")
#! Link("CSV:CP08:4210:ORDER_ONL.INPA","CSV:CP08:4210:ORDER_ON.VAL")
#! Field("CSV:CP08:4210:ORDER_ONL.INPB",16777215,0,"CSV:CP08:4210:ORDER_ONL.INPB")
#! Link("CSV:CP08:4210:ORDER_ONL.INPB","CSV:CP08:4210:ON_CFRM.VAL")
#! Field("CSV:CP08:4210:ORDER_ONL.INPC",16777215,0,"CSV:CP08:4210:ORDER_ONL.INPC")
#! Link("CSV:CP08:4210:ORDER_ONL.INPC","CSV:CP08:4210:ON_CNCL.VAL")
#! Field("CSV:CP08:4210:ORDER_ONL.VAL",16777215,1,"CSV:CP08:4210:ORDER_ONL.VAL")
#! Record("CSV:CP08:4210:ORDER_ONT",700,522,0,0,"CSV:CP08:4210:ORDER_ONT")
#! Field("CSV:CP08:4210:ORDER_ONT.DOL",16777215,0,"CSV:CP08:4210:ORDER_ONT.DOL")
#! Link("CSV:CP08:4210:ORDER_ONT.DOL","CSV:CP08:4210:ORDER_ONL.VAL")
#! Field("CSV:CP08:4210:ORDER_ONT.OUT",16777215,1,"CSV:CP08:4210:ORDER_ONT.OUT")
#! Link("CSV:CP08:4210:ORDER_ONT.OUT","CSV:CP08:4210:RQST_ON.VAL")
#! Record("CSV:CP08:4210:ORDER_OFFL",400,1124,0,1,"CSV:CP08:4210:ORDER_OFFL")
#! Field("CSV:CP08:4210:ORDER_OFFL.FLNK",16777215,1,"CSV:CP08:4210:ORDER_OFFL.FLNK")
#! Link("CSV:CP08:4210:ORDER_OFFL.FLNK","CSV:CP08:4210:ORDER_OFFT")
#! Field("CSV:CP08:4210:ORDER_OFFL.INPA",16777215,0,"CSV:CP08:4210:ORDER_OFFL.INPA")
#! Link("CSV:CP08:4210:ORDER_OFFL.INPA","CSV:CP08:4210:ORDER_OFF.VAL")
#! Field("CSV:CP08:4210:ORDER_OFFL.INPC",16777215,0,"CSV:CP08:4210:ORDER_OFFL.INPC")
#! Link("CSV:CP08:4210:ORDER_OFFL.INPC","CSV:CP08:4210:OFF_CNCL.VAL")
#! Field("CSV:CP08:4210:ORDER_OFFL.INPB",16777215,0,"CSV:CP08:4210:ORDER_OFFL.INPB")
#! Link("CSV:CP08:4210:ORDER_OFFL.INPB","CSV:CP08:4210:OFF_CFRM.VAL")
#! Field("CSV:CP08:4210:ORDER_OFFL.VAL",16777215,1,"CSV:CP08:4210:ORDER_OFFL.VAL")
#! Record("CSV:CP08:4210:ORDER_OFFT",700,1156,0,0,"CSV:CP08:4210:ORDER_OFFT")
#! Field("CSV:CP08:4210:ORDER_OFFT.DOL",16777215,0,"CSV:CP08:4210:ORDER_OFFT.DOL")
#! Link("CSV:CP08:4210:ORDER_OFFT.DOL","CSV:CP08:4210:ORDER_OFFL.VAL")
#! Field("CSV:CP08:4210:ORDER_OFFT.OUT",16777215,1,"CSV:CP08:4210:ORDER_OFFT.OUT")
#! Link("CSV:CP08:4210:ORDER_OFFT.OUT","CSV:CP08:4210:RQST_OFF.VAL")
#! TextBox(TB1,480,360,780,400,0,"Dialog",12,1,16777215,"Turn On and confirm logic\nTurn Off and confirm logic\n",null)
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "CSV:CP08:4004:ORDER_ON") {
  field(DESC, "C1 2KCB GV valve order on")
  field(ZNAM, "not ordered on")
  field(ONAM, "ordered on")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4004:ON_CNCL") {
  field(DESC, "C1 2KCB GV valve Cancel ON order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4004:ORDER_OFF") {
  field(DESC, "C1 2KCB GV valve order off")
  field(ZNAM, "not order off")
  field(ONAM, "order off")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4004:OFF_CNCL") {
  field(DESC, "C1 2KCB GV valve Cancel OFF order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4004:ON_CFRM") {
  field(DESC, "C1 2KCB GV valve confirm ON order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
  field(OMSL, "supervisory")
}

record(bo, "CSV:CP08:4004:OFF_CFRM") {
  field(DESC, "C1 2KCB GV valve confirm OFF order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4004:RQST_ON") {
  field(DESC, "C1 2KCB GV valve Rqst On")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) C1SV84004.EN B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(SCAN, "1 second")
  field(PINI, "NO")
  field(ASG, "NOWRITE")
  field(HIGH, "0")
  field(OMSL, "supervisory")
}

record(bo, "CSV:CP08:4004:RQST_OFF") {
  field(DESC, "C1 2KCB GV valve Rqst Off")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) C1SV84004.DIS B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(ASG, "NOWRITE")
  field(PINI, "NO")
  field(HIGH, "0")
  field(SCAN, "1 second")
  field(OMSL, "supervisory")
}

record(sub, "CSV:CP08:4004:ORDER_ONL") {
  field(DESC, "C1 2KCB GV valve")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CSV:CP08:4004:ORDER_ONT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CSV:CP08:4004:ORDER_ON")
  field(INPB, "CSV:CP08:4004:ON_CFRM")
  field(INPC, "CSV:CP08:4004:ON_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CSV:CP08:4004:ORDER_ONT") {
  field(DESC, "C1 2KCB GV valve")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "CSV:CP08:4004:ORDER_ONL")
  field(OUT, "CSV:CP08:4004:RQST_ON")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

record(sub, "CSV:CP08:4004:ORDER_OFFL") {
  field(DESC, "C1 2KCB GV valve")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CSV:CP08:4004:ORDER_OFFT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CSV:CP08:4004:ORDER_OFF")
  field(INPB, "CSV:CP08:4004:OFF_CFRM")
  field(INPC, "CSV:CP08:4004:OFF_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CSV:CP08:4004:ORDER_OFFT") {
  field(DESC, "C1 2KCB GV valve")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(OMSL, "closed_loop")
  field(DOL, "CSV:CP08:4004:ORDER_OFFL")
  field(OUT, "CSV:CP08:4004:RQST_OFF")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(0,416,1.1)
#! Record("CSV:CP08:4004:ORDER_ON",80,378,0,1,"CSV:CP08:4004:ORDER_ON")
#! Field("CSV:CP08:4004:ORDER_ON.VAL",16777215,1,"CSV:CP08:4004:ORDER_ON.VAL")
#! Record("CSV:CP08:4004:ON_CNCL",80,798,0,1,"CSV:CP08:4004:ON_CNCL")
#! Field("CSV:CP08:4004:ON_CNCL.VAL",16777215,1,"CSV:CP08:4004:ON_CNCL.VAL")
#! Record("CSV:CP08:4004:ORDER_OFF",80,1018,0,1,"CSV:CP08:4004:ORDER_OFF")
#! Field("CSV:CP08:4004:ORDER_OFF.VAL",16777215,1,"CSV:CP08:4004:ORDER_OFF.VAL")
#! Record("CSV:CP08:4004:OFF_CNCL",80,1458,0,1,"CSV:CP08:4004:OFF_CNCL")
#! Field("CSV:CP08:4004:OFF_CNCL.VAL",16777215,1,"CSV:CP08:4004:OFF_CNCL.VAL")
#! Record("CSV:CP08:4004:ON_CFRM",80,578,0,1,"CSV:CP08:4004:ON_CFRM")
#! Field("CSV:CP08:4004:ON_CFRM.VAL",16777215,1,"CSV:CP08:4004:ON_CFRM.VAL")
#! Record("CSV:CP08:4004:OFF_CFRM",80,1238,0,1,"CSV:CP08:4004:OFF_CFRM")
#! Field("CSV:CP08:4004:OFF_CFRM.VAL",16777215,1,"CSV:CP08:4004:OFF_CFRM.VAL")
#! Record("CSV:CP08:4004:RQST_ON",960,584,0,1,"CSV:CP08:4004:RQST_ON")
#! Field("CSV:CP08:4004:RQST_ON.VAL",16777215,1,"CSV:CP08:4004:RQST_ON.VAL")
#! Record("CSV:CP08:4004:RQST_OFF",960,1204,0,1,"CSV:CP08:4004:RQST_OFF")
#! Field("CSV:CP08:4004:RQST_OFF.VAL",16777215,1,"CSV:CP08:4004:RQST_OFF.VAL")
#! Record("CSV:CP08:4004:ORDER_ONL",400,524,0,1,"CSV:CP08:4004:ORDER_ONL")
#! Field("CSV:CP08:4004:ORDER_ONL.FLNK",16777215,1,"CSV:CP08:4004:ORDER_ONL.FLNK")
#! Link("CSV:CP08:4004:ORDER_ONL.FLNK","CSV:CP08:4004:ORDER_ONT")
#! Field("CSV:CP08:4004:ORDER_ONL.INPA",16777215,0,"CSV:CP08:4004:ORDER_ONL.INPA")
#! Link("CSV:CP08:4004:ORDER_ONL.INPA","CSV:CP08:4004:ORDER_ON.VAL")
#! Field("CSV:CP08:4004:ORDER_ONL.INPB",16777215,0,"CSV:CP08:4004:ORDER_ONL.INPB")
#! Link("CSV:CP08:4004:ORDER_ONL.INPB","CSV:CP08:4004:ON_CFRM.VAL")
#! Field("CSV:CP08:4004:ORDER_ONL.INPC",16777215,0,"CSV:CP08:4004:ORDER_ONL.INPC")
#! Link("CSV:CP08:4004:ORDER_ONL.INPC","CSV:CP08:4004:ON_CNCL.VAL")
#! Field("CSV:CP08:4004:ORDER_ONL.VAL",16777215,1,"CSV:CP08:4004:ORDER_ONL.VAL")
#! Record("CSV:CP08:4004:ORDER_ONT",700,522,0,0,"CSV:CP08:4004:ORDER_ONT")
#! Field("CSV:CP08:4004:ORDER_ONT.DOL",16777215,0,"CSV:CP08:4004:ORDER_ONT.DOL")
#! Link("CSV:CP08:4004:ORDER_ONT.DOL","CSV:CP08:4004:ORDER_ONL.VAL")
#! Field("CSV:CP08:4004:ORDER_ONT.OUT",16777215,1,"CSV:CP08:4004:ORDER_ONT.OUT")
#! Link("CSV:CP08:4004:ORDER_ONT.OUT","CSV:CP08:4004:RQST_ON.VAL")
#! Record("CSV:CP08:4004:ORDER_OFFL",400,1124,0,1,"CSV:CP08:4004:ORDER_OFFL")
#! Field("CSV:CP08:4004:ORDER_OFFL.FLNK",16777215,1,"CSV:CP08:4004:ORDER_OFFL.FLNK")
#! Link("CSV:CP08:4004:ORDER_OFFL.FLNK","CSV:CP08:4004:ORDER_OFFT")
#! Field("CSV:CP08:4004:ORDER_OFFL.INPA",16777215,0,"CSV:CP08:4004:ORDER_OFFL.INPA")
#! Link("CSV:CP08:4004:ORDER_OFFL.INPA","CSV:CP08:4004:ORDER_OFF.VAL")
#! Field("CSV:CP08:4004:ORDER_OFFL.INPC",16777215,0,"CSV:CP08:4004:ORDER_OFFL.INPC")
#! Link("CSV:CP08:4004:ORDER_OFFL.INPC","CSV:CP08:4004:OFF_CNCL.VAL")
#! Field("CSV:CP08:4004:ORDER_OFFL.INPB",16777215,0,"CSV:CP08:4004:ORDER_OFFL.INPB")
#! Link("CSV:CP08:4004:ORDER_OFFL.INPB","CSV:CP08:4004:OFF_CFRM.VAL")
#! Field("CSV:CP08:4004:ORDER_OFFL.VAL",16777215,1,"CSV:CP08:4004:ORDER_OFFL.VAL")
#! Record("CSV:CP08:4004:ORDER_OFFT",700,1156,0,0,"CSV:CP08:4004:ORDER_OFFT")
#! Field("CSV:CP08:4004:ORDER_OFFT.DOL",16777215,0,"CSV:CP08:4004:ORDER_OFFT.DOL")
#! Link("CSV:CP08:4004:ORDER_OFFT.DOL","CSV:CP08:4004:ORDER_OFFL.VAL")
#! Field("CSV:CP08:4004:ORDER_OFFT.OUT",16777215,1,"CSV:CP08:4004:ORDER_OFFT.OUT")
#! Link("CSV:CP08:4004:ORDER_OFFT.OUT","CSV:CP08:4004:RQST_OFF.VAL")
#! TextBox(TB1,480,360,780,400,0,"Dialog",12,1,16777215,"Turn On and confirm logic\nTurn Off and confirm logic\n",null)
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "CSV:CP08:4010:ORDER_ON") {
  field(DESC, "C1 IB GV valve order on")
  field(ZNAM, "not ordered on")
  field(ONAM, "ordered on")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4010:ON_CNCL") {
  field(DESC, "C1 IB GV valve Cancel ON order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4010:ORDER_OFF") {
  field(DESC, "C1 IB GV valve order off")
  field(ZNAM, "not order off")
  field(ONAM, "order off")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4010:OFF_CNCL") {
  field(DESC, "C1 IB GV valve Cancel OFF order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4010:ON_CFRM") {
  field(DESC, "C1 IB GV valve confirm ON order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
  field(OMSL, "supervisory")
}

record(bo, "CSV:CP08:4010:OFF_CFRM") {
  field(DESC, "C1 IB GV valve confirm OFF order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4010:RQST_ON") {
  field(DESC, "C1 IB GV valve Rqst On")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) C1SV84010.EN B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(SCAN, "1 second")
  field(PINI, "NO")
  field(ASG, "NOWRITE")
  field(HIGH, "0")
  field(OMSL, "supervisory")
}

record(bo, "CSV:CP08:4010:RQST_OFF") {
  field(DESC, "C1 IB GV valve Rqst Off")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) C1SV84010.DIS B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(ASG, "NOWRITE")
  field(PINI, "NO")
  field(HIGH, "0")
  field(SCAN, "1 second")
  field(OMSL, "supervisory")
}

record(sub, "CSV:CP08:4010:ORDER_ONL") {
  field(DESC, "C1 IB GV valve")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CSV:CP08:4010:ORDER_ONT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CSV:CP08:4010:ORDER_ON")
  field(INPB, "CSV:CP08:4010:ON_CFRM")
  field(INPC, "CSV:CP08:4010:ON_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CSV:CP08:4010:ORDER_ONT") {
  field(DESC, "C1 IB GV valve")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "CSV:CP08:4010:ORDER_ONL")
  field(OUT, "CSV:CP08:4010:RQST_ON")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

record(sub, "CSV:CP08:4010:ORDER_OFFL") {
  field(DESC, "C1 IB GV valve")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CSV:CP08:4010:ORDER_OFFT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CSV:CP08:4010:ORDER_OFF")
  field(INPB, "CSV:CP08:4010:OFF_CFRM")
  field(INPC, "CSV:CP08:4010:OFF_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CSV:CP08:4010:ORDER_OFFT") {
  field(DESC, "C1 IB GV valve")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(OMSL, "closed_loop")
  field(DOL, "CSV:CP08:4010:ORDER_OFFL")
  field(OUT, "CSV:CP08:4010:RQST_OFF")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(0,416,1.1)
#! Record("CSV:CP08:4010:ORDER_ON",80,378,0,1,"CSV:CP08:4010:ORDER_ON")
#! Field("CSV:CP08:4010:ORDER_ON.VAL",16777215,1,"CSV:CP08:4010:ORDER_ON.VAL")
#! Record("CSV:CP08:4010:ON_CNCL",80,798,0,1,"CSV:CP08:4010:ON_CNCL")
#! Field("CSV:CP08:4010:ON_CNCL.VAL",16777215,1,"CSV:CP08:4010:ON_CNCL.VAL")
#! Record("CSV:CP08:4010:ORDER_OFF",80,1018,0,1,"CSV:CP08:4010:ORDER_OFF")
#! Field("CSV:CP08:4010:ORDER_OFF.VAL",16777215,1,"CSV:CP08:4010:ORDER_OFF.VAL")
#! Record("CSV:CP08:4010:OFF_CNCL",80,1458,0,1,"CSV:CP08:4010:OFF_CNCL")
#! Field("CSV:CP08:4010:OFF_CNCL.VAL",16777215,1,"CSV:CP08:4010:OFF_CNCL.VAL")
#! Record("CSV:CP08:4010:ON_CFRM",80,578,0,1,"CSV:CP08:4010:ON_CFRM")
#! Field("CSV:CP08:4010:ON_CFRM.VAL",16777215,1,"CSV:CP08:4010:ON_CFRM.VAL")
#! Record("CSV:CP08:4010:OFF_CFRM",80,1238,0,1,"CSV:CP08:4010:OFF_CFRM")
#! Field("CSV:CP08:4010:OFF_CFRM.VAL",16777215,1,"CSV:CP08:4010:OFF_CFRM.VAL")
#! Record("CSV:CP08:4010:RQST_ON",960,584,0,1,"CSV:CP08:4010:RQST_ON")
#! Field("CSV:CP08:4010:RQST_ON.VAL",16777215,1,"CSV:CP08:4010:RQST_ON.VAL")
#! Record("CSV:CP08:4010:RQST_OFF",960,1204,0,1,"CSV:CP08:4010:RQST_OFF")
#! Field("CSV:CP08:4010:RQST_OFF.VAL",16777215,1,"CSV:CP08:4010:RQST_OFF.VAL")
#! Record("CSV:CP08:4010:ORDER_ONL",400,524,0,1,"CSV:CP08:4010:ORDER_ONL")
#! Field("CSV:CP08:4010:ORDER_ONL.FLNK",16777215,1,"CSV:CP08:4010:ORDER_ONL.FLNK")
#! Link("CSV:CP08:4010:ORDER_ONL.FLNK","CSV:CP08:4010:ORDER_ONT")
#! Field("CSV:CP08:4010:ORDER_ONL.INPA",16777215,0,"CSV:CP08:4010:ORDER_ONL.INPA")
#! Link("CSV:CP08:4010:ORDER_ONL.INPA","CSV:CP08:4010:ORDER_ON.VAL")
#! Field("CSV:CP08:4010:ORDER_ONL.INPB",16777215,0,"CSV:CP08:4010:ORDER_ONL.INPB")
#! Link("CSV:CP08:4010:ORDER_ONL.INPB","CSV:CP08:4010:ON_CFRM.VAL")
#! Field("CSV:CP08:4010:ORDER_ONL.INPC",16777215,0,"CSV:CP08:4010:ORDER_ONL.INPC")
#! Link("CSV:CP08:4010:ORDER_ONL.INPC","CSV:CP08:4010:ON_CNCL.VAL")
#! Field("CSV:CP08:4010:ORDER_ONL.VAL",16777215,1,"CSV:CP08:4010:ORDER_ONL.VAL")
#! Record("CSV:CP08:4010:ORDER_ONT",700,522,0,0,"CSV:CP08:4010:ORDER_ONT")
#! Field("CSV:CP08:4010:ORDER_ONT.DOL",16777215,0,"CSV:CP08:4010:ORDER_ONT.DOL")
#! Link("CSV:CP08:4010:ORDER_ONT.DOL","CSV:CP08:4010:ORDER_ONL.VAL")
#! Field("CSV:CP08:4010:ORDER_ONT.OUT",16777215,1,"CSV:CP08:4010:ORDER_ONT.OUT")
#! Link("CSV:CP08:4010:ORDER_ONT.OUT","CSV:CP08:4010:RQST_ON.VAL")
#! Record("CSV:CP08:4010:ORDER_OFFL",400,1124,0,1,"CSV:CP08:4010:ORDER_OFFL")
#! Field("CSV:CP08:4010:ORDER_OFFL.FLNK",16777215,1,"CSV:CP08:4010:ORDER_OFFL.FLNK")
#! Link("CSV:CP08:4010:ORDER_OFFL.FLNK","CSV:CP08:4010:ORDER_OFFT")
#! Field("CSV:CP08:4010:ORDER_OFFL.INPA",16777215,0,"CSV:CP08:4010:ORDER_OFFL.INPA")
#! Link("CSV:CP08:4010:ORDER_OFFL.INPA","CSV:CP08:4010:ORDER_OFF.VAL")
#! Field("CSV:CP08:4010:ORDER_OFFL.INPC",16777215,0,"CSV:CP08:4010:ORDER_OFFL.INPC")
#! Link("CSV:CP08:4010:ORDER_OFFL.INPC","CSV:CP08:4010:OFF_CNCL.VAL")
#! Field("CSV:CP08:4010:ORDER_OFFL.INPB",16777215,0,"CSV:CP08:4010:ORDER_OFFL.INPB")
#! Link("CSV:CP08:4010:ORDER_OFFL.INPB","CSV:CP08:4010:OFF_CFRM.VAL")
#! Field("CSV:CP08:4010:ORDER_OFFL.VAL",16777215,1,"CSV:CP08:4010:ORDER_OFFL.VAL")
#! Record("CSV:CP08:4010:ORDER_OFFT",700,1156,0,0,"CSV:CP08:4010:ORDER_OFFT")
#! Field("CSV:CP08:4010:ORDER_OFFT.DOL",16777215,0,"CSV:CP08:4010:ORDER_OFFT.DOL")
#! Link("CSV:CP08:4010:ORDER_OFFT.DOL","CSV:CP08:4010:ORDER_OFFL.VAL")
#! Field("CSV:CP08:4010:ORDER_OFFT.OUT",16777215,1,"CSV:CP08:4010:ORDER_OFFT.OUT")
#! Link("CSV:CP08:4010:ORDER_OFFT.OUT","CSV:CP08:4010:RQST_OFF.VAL")
#! TextBox(TB1,480,360,780,400,0,"Dialog",12,1,16777215,"Turn On and confirm logic\nTurn Off and confirm logic\n",null)
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "CSV:CP08:4020:ORDER_ON") {
  field(DESC, "C2 IB GV valve order on")
  field(ZNAM, "not ordered on")
  field(ONAM, "ordered on")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4020:ON_CNCL") {
  field(DESC, "C2 IB GV valve Cancel ON order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4020:ORDER_OFF") {
  field(DESC, "C2 IB GV valve order off")
  field(ZNAM, "not order off")
  field(ONAM, "order off")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4020:OFF_CNCL") {
  field(DESC, "C2 IB GV valve Cancel OFF order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4020:ON_CFRM") {
  field(DESC, "C2 IB GV valve confirm ON order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
  field(OMSL, "supervisory")
}

record(bo, "CSV:CP08:4020:OFF_CFRM") {
  field(DESC, "C2 IB GV valve confirm OFF order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4020:RQST_ON") {
  field(DESC, "C2 IB GV valve Rqst On")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) C2SV84020.EN B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(SCAN, "1 second")
  field(PINI, "NO")
  field(ASG, "NOWRITE")
  field(HIGH, "0")
  field(OMSL, "supervisory")
}

record(bo, "CSV:CP08:4020:RQST_OFF") {
  field(DESC, "C2 IB GV valve Rqst Off")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) C2SV84020.DIS B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(ASG, "NOWRITE")
  field(PINI, "NO")
  field(HIGH, "0")
  field(SCAN, "1 second")
  field(OMSL, "supervisory")
}

record(sub, "CSV:CP08:4020:ORDER_ONL") {
  field(DESC, "C2 IB GV valve")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CSV:CP08:4020:ORDER_ONT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CSV:CP08:4020:ORDER_ON")
  field(INPB, "CSV:CP08:4020:ON_CFRM")
  field(INPC, "CSV:CP08:4020:ON_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CSV:CP08:4020:ORDER_ONT") {
  field(DESC, "C2 IB GV valve")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "CSV:CP08:4020:ORDER_ONL")
  field(OUT, "CSV:CP08:4020:RQST_ON")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

record(sub, "CSV:CP08:4020:ORDER_OFFL") {
  field(DESC, "C2 IB GV valve")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CSV:CP08:4020:ORDER_OFFT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CSV:CP08:4020:ORDER_OFF")
  field(INPB, "CSV:CP08:4020:OFF_CFRM")
  field(INPC, "CSV:CP08:4020:OFF_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CSV:CP08:4020:ORDER_OFFT") {
  field(DESC, "C2 IB GV valve")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(OMSL, "closed_loop")
  field(DOL, "CSV:CP08:4020:ORDER_OFFL")
  field(OUT, "CSV:CP08:4020:RQST_OFF")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(0,416,1.1)
#! Record("CSV:CP08:4020:ORDER_ON",80,378,0,1,"CSV:CP08:4020:ORDER_ON")
#! Field("CSV:CP08:4020:ORDER_ON.VAL",16777215,1,"CSV:CP08:4020:ORDER_ON.VAL")
#! Record("CSV:CP08:4020:ON_CNCL",80,798,0,1,"CSV:CP08:4020:ON_CNCL")
#! Field("CSV:CP08:4020:ON_CNCL.VAL",16777215,1,"CSV:CP08:4020:ON_CNCL.VAL")
#! Record("CSV:CP08:4020:ORDER_OFF",80,1018,0,1,"CSV:CP08:4020:ORDER_OFF")
#! Field("CSV:CP08:4020:ORDER_OFF.VAL",16777215,1,"CSV:CP08:4020:ORDER_OFF.VAL")
#! Record("CSV:CP08:4020:OFF_CNCL",80,1458,0,1,"CSV:CP08:4020:OFF_CNCL")
#! Field("CSV:CP08:4020:OFF_CNCL.VAL",16777215,1,"CSV:CP08:4020:OFF_CNCL.VAL")
#! Record("CSV:CP08:4020:ON_CFRM",80,578,0,1,"CSV:CP08:4020:ON_CFRM")
#! Field("CSV:CP08:4020:ON_CFRM.VAL",16777215,1,"CSV:CP08:4020:ON_CFRM.VAL")
#! Record("CSV:CP08:4020:OFF_CFRM",80,1238,0,1,"CSV:CP08:4020:OFF_CFRM")
#! Field("CSV:CP08:4020:OFF_CFRM.VAL",16777215,1,"CSV:CP08:4020:OFF_CFRM.VAL")
#! Record("CSV:CP08:4020:RQST_ON",960,584,0,1,"CSV:CP08:4020:RQST_ON")
#! Field("CSV:CP08:4020:RQST_ON.VAL",16777215,1,"CSV:CP08:4020:RQST_ON.VAL")
#! Record("CSV:CP08:4020:RQST_OFF",960,1204,0,1,"CSV:CP08:4020:RQST_OFF")
#! Field("CSV:CP08:4020:RQST_OFF.VAL",16777215,1,"CSV:CP08:4020:RQST_OFF.VAL")
#! Record("CSV:CP08:4020:ORDER_ONL",400,524,0,1,"CSV:CP08:4020:ORDER_ONL")
#! Field("CSV:CP08:4020:ORDER_ONL.FLNK",16777215,1,"CSV:CP08:4020:ORDER_ONL.FLNK")
#! Link("CSV:CP08:4020:ORDER_ONL.FLNK","CSV:CP08:4020:ORDER_ONT")
#! Field("CSV:CP08:4020:ORDER_ONL.INPA",16777215,0,"CSV:CP08:4020:ORDER_ONL.INPA")
#! Link("CSV:CP08:4020:ORDER_ONL.INPA","CSV:CP08:4020:ORDER_ON.VAL")
#! Field("CSV:CP08:4020:ORDER_ONL.INPB",16777215,0,"CSV:CP08:4020:ORDER_ONL.INPB")
#! Link("CSV:CP08:4020:ORDER_ONL.INPB","CSV:CP08:4020:ON_CFRM.VAL")
#! Field("CSV:CP08:4020:ORDER_ONL.INPC",16777215,0,"CSV:CP08:4020:ORDER_ONL.INPC")
#! Link("CSV:CP08:4020:ORDER_ONL.INPC","CSV:CP08:4020:ON_CNCL.VAL")
#! Field("CSV:CP08:4020:ORDER_ONL.VAL",16777215,1,"CSV:CP08:4020:ORDER_ONL.VAL")
#! Record("CSV:CP08:4020:ORDER_ONT",700,522,0,0,"CSV:CP08:4020:ORDER_ONT")
#! Field("CSV:CP08:4020:ORDER_ONT.DOL",16777215,0,"CSV:CP08:4020:ORDER_ONT.DOL")
#! Link("CSV:CP08:4020:ORDER_ONT.DOL","CSV:CP08:4020:ORDER_ONL.VAL")
#! Field("CSV:CP08:4020:ORDER_ONT.OUT",16777215,1,"CSV:CP08:4020:ORDER_ONT.OUT")
#! Link("CSV:CP08:4020:ORDER_ONT.OUT","CSV:CP08:4020:RQST_ON.VAL")
#! Record("CSV:CP08:4020:ORDER_OFFL",400,1124,0,1,"CSV:CP08:4020:ORDER_OFFL")
#! Field("CSV:CP08:4020:ORDER_OFFL.FLNK",16777215,1,"CSV:CP08:4020:ORDER_OFFL.FLNK")
#! Link("CSV:CP08:4020:ORDER_OFFL.FLNK","CSV:CP08:4020:ORDER_OFFT")
#! Field("CSV:CP08:4020:ORDER_OFFL.INPA",16777215,0,"CSV:CP08:4020:ORDER_OFFL.INPA")
#! Link("CSV:CP08:4020:ORDER_OFFL.INPA","CSV:CP08:4020:ORDER_OFF.VAL")
#! Field("CSV:CP08:4020:ORDER_OFFL.INPC",16777215,0,"CSV:CP08:4020:ORDER_OFFL.INPC")
#! Link("CSV:CP08:4020:ORDER_OFFL.INPC","CSV:CP08:4020:OFF_CNCL.VAL")
#! Field("CSV:CP08:4020:ORDER_OFFL.INPB",16777215,0,"CSV:CP08:4020:ORDER_OFFL.INPB")
#! Link("CSV:CP08:4020:ORDER_OFFL.INPB","CSV:CP08:4020:OFF_CFRM.VAL")
#! Field("CSV:CP08:4020:ORDER_OFFL.VAL",16777215,1,"CSV:CP08:4020:ORDER_OFFL.VAL")
#! Record("CSV:CP08:4020:ORDER_OFFT",700,1156,0,0,"CSV:CP08:4020:ORDER_OFFT")
#! Field("CSV:CP08:4020:ORDER_OFFT.DOL",16777215,0,"CSV:CP08:4020:ORDER_OFFT.DOL")
#! Link("CSV:CP08:4020:ORDER_OFFT.DOL","CSV:CP08:4020:ORDER_OFFL.VAL")
#! Field("CSV:CP08:4020:ORDER_OFFT.OUT",16777215,1,"CSV:CP08:4020:ORDER_OFFT.OUT")
#! Link("CSV:CP08:4020:ORDER_OFFT.OUT","CSV:CP08:4020:RQST_OFF.VAL")
#! TextBox(TB1,480,360,780,400,0,"Dialog",12,1,16777215,"Turn On and confirm logic\nTurn Off and confirm logic\n",null)
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "CSV:CP08:4030:ORDER_ON") {
  field(DESC, "C2 2KCB GV valve order on")
  field(ZNAM, "not ordered on")
  field(ONAM, "ordered on")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4030:ON_CNCL") {
  field(DESC, "C2 2KCB GV valve Cancel ON order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4030:ORDER_OFF") {
  field(DESC, "C2 2KCB GV valve order off")
  field(ZNAM, "not order off")
  field(ONAM, "order off")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4030:OFF_CNCL") {
  field(DESC, "C2 2KCB GV valve Cancel OFF order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4030:ON_CFRM") {
  field(DESC, "C2 2KCB GV valve confirm ON order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
  field(OMSL, "supervisory")
}

record(bo, "CSV:CP08:4030:OFF_CFRM") {
  field(DESC, "C2 2KCB GV valve confirm OFF order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CSV:CP08:4030:RQST_ON") {
  field(DESC, "C2 2KCB GV valve Rqst On")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) C2SV84030.EN B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(SCAN, "1 second")
  field(PINI, "NO")
  field(ASG, "NOWRITE")
  field(HIGH, "0")
  field(OMSL, "supervisory")
}

record(bo, "CSV:CP08:4030:RQST_OFF") {
  field(DESC, "C2 2KCB GV valve Rqst Off")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) C2SV84030.DIS B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(ASG, "NOWRITE")
  field(PINI, "NO")
  field(HIGH, "0")
  field(SCAN, "1 second")
  field(OMSL, "supervisory")
}

record(sub, "CSV:CP08:4030:ORDER_ONL") {
  field(DESC, "C2 2KCB GV valve")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CSV:CP08:4030:ORDER_ONT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CSV:CP08:4030:ORDER_ON")
  field(INPB, "CSV:CP08:4030:ON_CFRM")
  field(INPC, "CSV:CP08:4030:ON_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CSV:CP08:4030:ORDER_ONT") {
  field(DESC, "C2 2KCB GV valve")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "CSV:CP08:4030:ORDER_ONL")
  field(OUT, "CSV:CP08:4030:RQST_ON")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

record(sub, "CSV:CP08:4030:ORDER_OFFL") {
  field(DESC, "C2 2KCB GV valve")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CSV:CP08:4030:ORDER_OFFT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CSV:CP08:4030:ORDER_OFF")
  field(INPB, "CSV:CP08:4030:OFF_CFRM")
  field(INPC, "CSV:CP08:4030:OFF_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CSV:CP08:4030:ORDER_OFFT") {
  field(DESC, "C2 2KCB GV valve")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(OMSL, "closed_loop")
  field(DOL, "CSV:CP08:4030:ORDER_OFFL")
  field(OUT, "CSV:CP08:4030:RQST_OFF")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(0,416,1.1)
#! Record("CSV:CP08:4030:ORDER_ON",80,378,0,1,"CSV:CP08:4030:ORDER_ON")
#! Field("CSV:CP08:4030:ORDER_ON.VAL",16777215,1,"CSV:CP08:4030:ORDER_ON.VAL")
#! Record("CSV:CP08:4030:ON_CNCL",80,798,0,1,"CSV:CP08:4030:ON_CNCL")
#! Field("CSV:CP08:4030:ON_CNCL.VAL",16777215,1,"CSV:CP08:4030:ON_CNCL.VAL")
#! Record("CSV:CP08:4030:ORDER_OFF",80,1018,0,1,"CSV:CP08:4030:ORDER_OFF")
#! Field("CSV:CP08:4030:ORDER_OFF.VAL",16777215,1,"CSV:CP08:4030:ORDER_OFF.VAL")
#! Record("CSV:CP08:4030:OFF_CNCL",80,1458,0,1,"CSV:CP08:4030:OFF_CNCL")
#! Field("CSV:CP08:4030:OFF_CNCL.VAL",16777215,1,"CSV:CP08:4030:OFF_CNCL.VAL")
#! Record("CSV:CP08:4030:ON_CFRM",80,578,0,1,"CSV:CP08:4030:ON_CFRM")
#! Field("CSV:CP08:4030:ON_CFRM.VAL",16777215,1,"CSV:CP08:4030:ON_CFRM.VAL")
#! Record("CSV:CP08:4030:OFF_CFRM",80,1238,0,1,"CSV:CP08:4030:OFF_CFRM")
#! Field("CSV:CP08:4030:OFF_CFRM.VAL",16777215,1,"CSV:CP08:4030:OFF_CFRM.VAL")
#! Record("CSV:CP08:4030:RQST_ON",960,584,0,1,"CSV:CP08:4030:RQST_ON")
#! Field("CSV:CP08:4030:RQST_ON.VAL",16777215,1,"CSV:CP08:4030:RQST_ON.VAL")
#! Record("CSV:CP08:4030:RQST_OFF",960,1204,0,1,"CSV:CP08:4030:RQST_OFF")
#! Field("CSV:CP08:4030:RQST_OFF.VAL",16777215,1,"CSV:CP08:4030:RQST_OFF.VAL")
#! Record("CSV:CP08:4030:ORDER_ONL",400,524,0,1,"CSV:CP08:4030:ORDER_ONL")
#! Field("CSV:CP08:4030:ORDER_ONL.FLNK",16777215,1,"CSV:CP08:4030:ORDER_ONL.FLNK")
#! Link("CSV:CP08:4030:ORDER_ONL.FLNK","CSV:CP08:4030:ORDER_ONT")
#! Field("CSV:CP08:4030:ORDER_ONL.INPA",16777215,0,"CSV:CP08:4030:ORDER_ONL.INPA")
#! Link("CSV:CP08:4030:ORDER_ONL.INPA","CSV:CP08:4030:ORDER_ON.VAL")
#! Field("CSV:CP08:4030:ORDER_ONL.INPB",16777215,0,"CSV:CP08:4030:ORDER_ONL.INPB")
#! Link("CSV:CP08:4030:ORDER_ONL.INPB","CSV:CP08:4030:ON_CFRM.VAL")
#! Field("CSV:CP08:4030:ORDER_ONL.INPC",16777215,0,"CSV:CP08:4030:ORDER_ONL.INPC")
#! Link("CSV:CP08:4030:ORDER_ONL.INPC","CSV:CP08:4030:ON_CNCL.VAL")
#! Field("CSV:CP08:4030:ORDER_ONL.VAL",16777215,1,"CSV:CP08:4030:ORDER_ONL.VAL")
#! Record("CSV:CP08:4030:ORDER_ONT",700,522,0,0,"CSV:CP08:4030:ORDER_ONT")
#! Field("CSV:CP08:4030:ORDER_ONT.DOL",16777215,0,"CSV:CP08:4030:ORDER_ONT.DOL")
#! Link("CSV:CP08:4030:ORDER_ONT.DOL","CSV:CP08:4030:ORDER_ONL.VAL")
#! Field("CSV:CP08:4030:ORDER_ONT.OUT",16777215,1,"CSV:CP08:4030:ORDER_ONT.OUT")
#! Link("CSV:CP08:4030:ORDER_ONT.OUT","CSV:CP08:4030:RQST_ON.VAL")
#! Record("CSV:CP08:4030:ORDER_OFFL",400,1124,0,1,"CSV:CP08:4030:ORDER_OFFL")
#! Field("CSV:CP08:4030:ORDER_OFFL.FLNK",16777215,1,"CSV:CP08:4030:ORDER_OFFL.FLNK")
#! Link("CSV:CP08:4030:ORDER_OFFL.FLNK","CSV:CP08:4030:ORDER_OFFT")
#! Field("CSV:CP08:4030:ORDER_OFFL.INPA",16777215,0,"CSV:CP08:4030:ORDER_OFFL.INPA")
#! Link("CSV:CP08:4030:ORDER_OFFL.INPA","CSV:CP08:4030:ORDER_OFF.VAL")
#! Field("CSV:CP08:4030:ORDER_OFFL.INPC",16777215,0,"CSV:CP08:4030:ORDER_OFFL.INPC")
#! Link("CSV:CP08:4030:ORDER_OFFL.INPC","CSV:CP08:4030:OFF_CNCL.VAL")
#! Field("CSV:CP08:4030:ORDER_OFFL.INPB",16777215,0,"CSV:CP08:4030:ORDER_OFFL.INPB")
#! Link("CSV:CP08:4030:ORDER_OFFL.INPB","CSV:CP08:4030:OFF_CFRM.VAL")
#! Field("CSV:CP08:4030:ORDER_OFFL.VAL",16777215,1,"CSV:CP08:4030:ORDER_OFFL.VAL")
#! Record("CSV:CP08:4030:ORDER_OFFT",700,1156,0,0,"CSV:CP08:4030:ORDER_OFFT")
#! Field("CSV:CP08:4030:ORDER_OFFT.DOL",16777215,0,"CSV:CP08:4030:ORDER_OFFT.DOL")
#! Link("CSV:CP08:4030:ORDER_OFFT.DOL","CSV:CP08:4030:ORDER_OFFL.VAL")
#! Field("CSV:CP08:4030:ORDER_OFFT.OUT",16777215,1,"CSV:CP08:4030:ORDER_OFFT.OUT")
#! Link("CSV:CP08:4030:ORDER_OFFT.OUT","CSV:CP08:4030:RQST_OFF.VAL")
#! TextBox(TB1,480,360,780,400,0,"Dialog",12,1,16777215,"Turn On and confirm logic\nTurn Off and confirm logic\n",null)
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "CHTR:CP07:2110:ORDER_ON") {
  field(DESC, "Rec.Cmpr1 HTR order on")
  field(ZNAM, "not ordered on")
  field(ONAM, "ordered on")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CHTR:CP07:2110:ON_CNCL") {
  field(DESC, "Rec.Cmpr1 HTR Cancel ON order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CHTR:CP07:2110:ORDER_OFF") {
  field(DESC, "Rec.Cmpr1 HTR order off")
  field(ZNAM, "not order off")
  field(ONAM, "order off")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CHTR:CP07:2110:OFF_CNCL") {
  field(DESC, "Rec.Cmpr1 HTR Cancel OFF order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CHTR:CP07:2110:ON_CFRM") {
  field(DESC, "Rec.Cmpr1 HTR confirm ON order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
  field(OMSL, "supervisory")
}

record(bo, "CHTR:CP07:2110:OFF_CFRM") {
  field(DESC, "Rec.Cmpr1 HTR confirm OFF order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CHTR:CP07:2110:RQST_ON") {
  field(DESC, "Rec.Cmpr1 HTR Rqst On")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CHTR72110.EN B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(SCAN, "1 second")
  field(PINI, "NO")
  field(ASG, "NOWRITE")
  field(HIGH, "0")
  field(OMSL, "supervisory")
}

record(bo, "CHTR:CP07:2110:RQST_OFF") {
  field(DESC, "Rec.Cmpr1 HTR Rqst Off")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CHTR72110.DIS B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(ASG, "NOWRITE")
  field(PINI, "NO")
  field(HIGH, "0")
  field(SCAN, "1 second")
  field(OMSL, "supervisory")
}

record(sub, "CHTR:CP07:2110:ORDER_ONL") {
  field(DESC, "Rec.Cmpr1 HTR")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CHTR:CP07:2110:ORDER_ONT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CHTR:CP07:2110:ORDER_ON")
  field(INPB, "CHTR:CP07:2110:ON_CFRM")
  field(INPC, "CHTR:CP07:2110:ON_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CHTR:CP07:2110:ORDER_ONT") {
  field(DESC, "Rec.Cmpr1 HTR")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "CHTR:CP07:2110:ORDER_ONL")
  field(OUT, "CHTR:CP07:2110:RQST_ON")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

record(sub, "CHTR:CP07:2110:ORDER_OFFL") {
  field(DESC, "Rec.Cmpr1 HTR")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CHTR:CP07:2110:ORDER_OFFT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CHTR:CP07:2110:ORDER_OFF")
  field(INPB, "CHTR:CP07:2110:OFF_CFRM")
  field(INPC, "CHTR:CP07:2110:OFF_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CHTR:CP07:2110:ORDER_OFFT") {
  field(DESC, "Rec.Cmpr1 HTR")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(OMSL, "closed_loop")
  field(DOL, "CHTR:CP07:2110:ORDER_OFFL")
  field(OUT, "CHTR:CP07:2110:RQST_OFF")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(0,416,1.1)
#! Record("CHTR:CP07:2110:ORDER_ON",80,378,0,1,"CHTR:CP07:2110:ORDER_ON")
#! Field("CHTR:CP07:2110:ORDER_ON.VAL",16777215,1,"CHTR:CP07:2110:ORDER_ON.VAL")
#! Record("CHTR:CP07:2110:ON_CNCL",80,798,0,1,"CHTR:CP07:2110:ON_CNCL")
#! Field("CHTR:CP07:2110:ON_CNCL.VAL",16777215,1,"CHTR:CP07:2110:ON_CNCL.VAL")
#! Record("CHTR:CP07:2110:ORDER_OFF",80,1018,0,1,"CHTR:CP07:2110:ORDER_OFF")
#! Field("CHTR:CP07:2110:ORDER_OFF.VAL",16777215,1,"CHTR:CP07:2110:ORDER_OFF.VAL")
#! Record("CHTR:CP07:2110:OFF_CNCL",80,1458,0,1,"CHTR:CP07:2110:OFF_CNCL")
#! Field("CHTR:CP07:2110:OFF_CNCL.VAL",16777215,1,"CHTR:CP07:2110:OFF_CNCL.VAL")
#! Record("CHTR:CP07:2110:ON_CFRM",80,578,0,1,"CHTR:CP07:2110:ON_CFRM")
#! Field("CHTR:CP07:2110:ON_CFRM.VAL",16777215,1,"CHTR:CP07:2110:ON_CFRM.VAL")
#! Record("CHTR:CP07:2110:OFF_CFRM",80,1238,0,1,"CHTR:CP07:2110:OFF_CFRM")
#! Field("CHTR:CP07:2110:OFF_CFRM.VAL",16777215,1,"CHTR:CP07:2110:OFF_CFRM.VAL")
#! Record("CHTR:CP07:2110:RQST_ON",960,584,0,1,"CHTR:CP07:2110:RQST_ON")
#! Field("CHTR:CP07:2110:RQST_ON.VAL",16777215,1,"CHTR:CP07:2110:RQST_ON.VAL")
#! Record("CHTR:CP07:2110:RQST_OFF",960,1204,0,1,"CHTR:CP07:2110:RQST_OFF")
#! Field("CHTR:CP07:2110:RQST_OFF.VAL",16777215,1,"CHTR:CP07:2110:RQST_OFF.VAL")
#! Record("CHTR:CP07:2110:ORDER_ONL",400,524,0,1,"CHTR:CP07:2110:ORDER_ONL")
#! Field("CHTR:CP07:2110:ORDER_ONL.FLNK",16777215,1,"CHTR:CP07:2110:ORDER_ONL.FLNK")
#! Link("CHTR:CP07:2110:ORDER_ONL.FLNK","CHTR:CP07:2110:ORDER_ONT")
#! Field("CHTR:CP07:2110:ORDER_ONL.INPA",16777215,0,"CHTR:CP07:2110:ORDER_ONL.INPA")
#! Link("CHTR:CP07:2110:ORDER_ONL.INPA","CHTR:CP07:2110:ORDER_ON.VAL")
#! Field("CHTR:CP07:2110:ORDER_ONL.INPB",16777215,0,"CHTR:CP07:2110:ORDER_ONL.INPB")
#! Link("CHTR:CP07:2110:ORDER_ONL.INPB","CHTR:CP07:2110:ON_CFRM.VAL")
#! Field("CHTR:CP07:2110:ORDER_ONL.INPC",16777215,0,"CHTR:CP07:2110:ORDER_ONL.INPC")
#! Link("CHTR:CP07:2110:ORDER_ONL.INPC","CHTR:CP07:2110:ON_CNCL.VAL")
#! Field("CHTR:CP07:2110:ORDER_ONL.VAL",16777215,1,"CHTR:CP07:2110:ORDER_ONL.VAL")
#! Record("CHTR:CP07:2110:ORDER_ONT",700,522,0,0,"CHTR:CP07:2110:ORDER_ONT")
#! Field("CHTR:CP07:2110:ORDER_ONT.DOL",16777215,0,"CHTR:CP07:2110:ORDER_ONT.DOL")
#! Link("CHTR:CP07:2110:ORDER_ONT.DOL","CHTR:CP07:2110:ORDER_ONL.VAL")
#! Field("CHTR:CP07:2110:ORDER_ONT.OUT",16777215,1,"CHTR:CP07:2110:ORDER_ONT.OUT")
#! Link("CHTR:CP07:2110:ORDER_ONT.OUT","CHTR:CP07:2110:RQST_ON.VAL")
#! Record("CHTR:CP07:2110:ORDER_OFFL",400,1124,0,1,"CHTR:CP07:2110:ORDER_OFFL")
#! Field("CHTR:CP07:2110:ORDER_OFFL.FLNK",16777215,1,"CHTR:CP07:2110:ORDER_OFFL.FLNK")
#! Link("CHTR:CP07:2110:ORDER_OFFL.FLNK","CHTR:CP07:2110:ORDER_OFFT")
#! Field("CHTR:CP07:2110:ORDER_OFFL.INPA",16777215,0,"CHTR:CP07:2110:ORDER_OFFL.INPA")
#! Link("CHTR:CP07:2110:ORDER_OFFL.INPA","CHTR:CP07:2110:ORDER_OFF.VAL")
#! Field("CHTR:CP07:2110:ORDER_OFFL.INPC",16777215,0,"CHTR:CP07:2110:ORDER_OFFL.INPC")
#! Link("CHTR:CP07:2110:ORDER_OFFL.INPC","CHTR:CP07:2110:OFF_CNCL.VAL")
#! Field("CHTR:CP07:2110:ORDER_OFFL.INPB",16777215,0,"CHTR:CP07:2110:ORDER_OFFL.INPB")
#! Link("CHTR:CP07:2110:ORDER_OFFL.INPB","CHTR:CP07:2110:OFF_CFRM.VAL")
#! Field("CHTR:CP07:2110:ORDER_OFFL.VAL",16777215,1,"CHTR:CP07:2110:ORDER_OFFL.VAL")
#! Record("CHTR:CP07:2110:ORDER_OFFT",700,1156,0,0,"CHTR:CP07:2110:ORDER_OFFT")
#! Field("CHTR:CP07:2110:ORDER_OFFT.DOL",16777215,0,"CHTR:CP07:2110:ORDER_OFFT.DOL")
#! Link("CHTR:CP07:2110:ORDER_OFFT.DOL","CHTR:CP07:2110:ORDER_OFFL.VAL")
#! Field("CHTR:CP07:2110:ORDER_OFFT.OUT",16777215,1,"CHTR:CP07:2110:ORDER_OFFT.OUT")
#! Link("CHTR:CP07:2110:ORDER_OFFT.OUT","CHTR:CP07:2110:RQST_OFF.VAL")
#! TextBox(TB1,480,360,780,400,0,"Dialog",12,1,16777215,"Turn On and confirm logic\nTurn Off and confirm logic\n",null)
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "CHTR:CP07:2210:ORDER_ON") {
  field(DESC, "Rec.Cmpr2 HTR order on")
  field(ZNAM, "not ordered on")
  field(ONAM, "ordered on")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CHTR:CP07:2210:ON_CNCL") {
  field(DESC, "Rec.Cmpr2 HTR Cancel ON order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CHTR:CP07:2210:ORDER_OFF") {
  field(DESC, "Rec.Cmpr2 HTR order off")
  field(ZNAM, "not order off")
  field(ONAM, "order off")
  field(OMSL, "supervisory")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CHTR:CP07:2210:OFF_CNCL") {
  field(DESC, "Rec.Cmpr2 HTR Cancel OFF order")
  field(ZNAM, "not cancelled")
  field(ONAM, "cancelled")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CHTR:CP07:2210:ON_CFRM") {
  field(DESC, "Rec.Cmpr2 HTR confirm ON order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(HIGH, "1")
  field(ASG, "CRYO")
  field(OMSL, "supervisory")
}

record(bo, "CHTR:CP07:2210:OFF_CFRM") {
  field(DESC, "Rec.Cmpr2 HTR confirm OFF order")
  field(ZNAM, "not confirmed")
  field(ONAM, "confirmed")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "supervisory")
  field(HIGH, "1")
  field(ASG, "CRYO")
}

record(bo, "CHTR:CP07:2210:RQST_ON") {
  field(DESC, "Rec.Cmpr2 HTR Rqst On")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CHTR72210.EN B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(SCAN, "1 second")
  field(PINI, "NO")
  field(ASG, "NOWRITE")
  field(HIGH, "0")
  field(OMSL, "supervisory")
}

record(bo, "CHTR:CP07:2210:RQST_OFF") {
  field(DESC, "Rec.Cmpr2 HTR Rqst Off")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) CHTR72210.DIS B 0")
  field(ZNAM, "not active")
  field(ONAM, "Active")
  field(ASG, "NOWRITE")
  field(PINI, "NO")
  field(HIGH, "0")
  field(SCAN, "1 second")
  field(OMSL, "supervisory")
}

record(sub, "CHTR:CP07:2210:ORDER_ONL") {
  field(DESC, "Rec.Cmpr2 HTR")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CHTR:CP07:2210:ORDER_ONT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CHTR:CP07:2210:ORDER_ON")
  field(INPB, "CHTR:CP07:2210:ON_CFRM")
  field(INPC, "CHTR:CP07:2210:ON_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CHTR:CP07:2210:ORDER_ONT") {
  field(DESC, "Rec.Cmpr2 HTR")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(DTYP, "Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "CHTR:CP07:2210:ORDER_ONL")
  field(OUT, "CHTR:CP07:2210:RQST_ON")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

record(sub, "CHTR:CP07:2210:ORDER_OFFL") {
  field(DESC, "Rec.Cmpr2 HTR")
  field(SCAN, ".5 second")
  field(PINI, "NO")
  field(FLNK, "CHTR:CP07:2210:ORDER_OFFT")
  field(INAM, "Icclmom")
  field(SNAM, "Scclmom")
  field(INPA, "CHTR:CP07:2210:ORDER_OFF")
  field(INPB, "CHTR:CP07:2210:OFF_CFRM")
  field(INPC, "CHTR:CP07:2210:OFF_CNCL")
  field(ASG, "NOWRITE")
}

record(bo, "CHTR:CP07:2210:ORDER_OFFT") {
  field(DESC, "Rec.Cmpr2 HTR")
  field(SCAN, "Passive")
  field(PINI, "NO")
  field(OMSL, "closed_loop")
  field(DOL, "CHTR:CP07:2210:ORDER_OFFL")
  field(OUT, "CHTR:CP07:2210:RQST_OFF")
  field(ZSV, "MAJOR")
  field(ASG, "NOWRITE")
  field(ZNAM, "disabled")
  field(ONAM, "enabled")
  field(OSV, "NO_ALARM")
  field(COSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(0,416,1.1)
#! Record("CHTR:CP07:2210:ORDER_ON",80,378,0,1,"CHTR:CP07:2210:ORDER_ON")
#! Field("CHTR:CP07:2210:ORDER_ON.VAL",16777215,1,"CHTR:CP07:2210:ORDER_ON.VAL")
#! Record("CHTR:CP07:2210:ON_CNCL",80,798,0,1,"CHTR:CP07:2210:ON_CNCL")
#! Field("CHTR:CP07:2210:ON_CNCL.VAL",16777215,1,"CHTR:CP07:2210:ON_CNCL.VAL")
#! Record("CHTR:CP07:2210:ORDER_OFF",80,1018,0,1,"CHTR:CP07:2210:ORDER_OFF")
#! Field("CHTR:CP07:2210:ORDER_OFF.VAL",16777215,1,"CHTR:CP07:2210:ORDER_OFF.VAL")
#! Record("CHTR:CP07:2210:OFF_CNCL",80,1458,0,1,"CHTR:CP07:2210:OFF_CNCL")
#! Field("CHTR:CP07:2210:OFF_CNCL.VAL",16777215,1,"CHTR:CP07:2210:OFF_CNCL.VAL")
#! Record("CHTR:CP07:2210:ON_CFRM",80,578,0,1,"CHTR:CP07:2210:ON_CFRM")
#! Field("CHTR:CP07:2210:ON_CFRM.VAL",16777215,1,"CHTR:CP07:2210:ON_CFRM.VAL")
#! Record("CHTR:CP07:2210:OFF_CFRM",80,1238,0,1,"CHTR:CP07:2210:OFF_CFRM")
#! Field("CHTR:CP07:2210:OFF_CFRM.VAL",16777215,1,"CHTR:CP07:2210:OFF_CFRM.VAL")
#! Record("CHTR:CP07:2210:RQST_ON",960,584,0,1,"CHTR:CP07:2210:RQST_ON")
#! Field("CHTR:CP07:2210:RQST_ON.VAL",16777215,1,"CHTR:CP07:2210:RQST_ON.VAL")
#! Record("CHTR:CP07:2210:RQST_OFF",960,1204,0,1,"CHTR:CP07:2210:RQST_OFF")
#! Field("CHTR:CP07:2210:RQST_OFF.VAL",16777215,1,"CHTR:CP07:2210:RQST_OFF.VAL")
#! Record("CHTR:CP07:2210:ORDER_ONL",400,524,0,1,"CHTR:CP07:2210:ORDER_ONL")
#! Field("CHTR:CP07:2210:ORDER_ONL.FLNK",16777215,1,"CHTR:CP07:2210:ORDER_ONL.FLNK")
#! Link("CHTR:CP07:2210:ORDER_ONL.FLNK","CHTR:CP07:2210:ORDER_ONT")
#! Field("CHTR:CP07:2210:ORDER_ONL.INPA",16777215,0,"CHTR:CP07:2210:ORDER_ONL.INPA")
#! Link("CHTR:CP07:2210:ORDER_ONL.INPA","CHTR:CP07:2210:ORDER_ON.VAL")
#! Field("CHTR:CP07:2210:ORDER_ONL.INPB",16777215,0,"CHTR:CP07:2210:ORDER_ONL.INPB")
#! Link("CHTR:CP07:2210:ORDER_ONL.INPB","CHTR:CP07:2210:ON_CFRM.VAL")
#! Field("CHTR:CP07:2210:ORDER_ONL.INPC",16777215,0,"CHTR:CP07:2210:ORDER_ONL.INPC")
#! Link("CHTR:CP07:2210:ORDER_ONL.INPC","CHTR:CP07:2210:ON_CNCL.VAL")
#! Field("CHTR:CP07:2210:ORDER_ONL.VAL",16777215,1,"CHTR:CP07:2210:ORDER_ONL.VAL")
#! Record("CHTR:CP07:2210:ORDER_ONT",700,522,0,0,"CHTR:CP07:2210:ORDER_ONT")
#! Field("CHTR:CP07:2210:ORDER_ONT.DOL",16777215,0,"CHTR:CP07:2210:ORDER_ONT.DOL")
#! Link("CHTR:CP07:2210:ORDER_ONT.DOL","CHTR:CP07:2210:ORDER_ONL.VAL")
#! Field("CHTR:CP07:2210:ORDER_ONT.OUT",16777215,1,"CHTR:CP07:2210:ORDER_ONT.OUT")
#! Link("CHTR:CP07:2210:ORDER_ONT.OUT","CHTR:CP07:2210:RQST_ON.VAL")
#! Record("CHTR:CP07:2210:ORDER_OFFL",400,1124,0,1,"CHTR:CP07:2210:ORDER_OFFL")
#! Field("CHTR:CP07:2210:ORDER_OFFL.FLNK",16777215,1,"CHTR:CP07:2210:ORDER_OFFL.FLNK")
#! Link("CHTR:CP07:2210:ORDER_OFFL.FLNK","CHTR:CP07:2210:ORDER_OFFT")
#! Field("CHTR:CP07:2210:ORDER_OFFL.INPA",16777215,0,"CHTR:CP07:2210:ORDER_OFFL.INPA")
#! Link("CHTR:CP07:2210:ORDER_OFFL.INPA","CHTR:CP07:2210:ORDER_OFF.VAL")
#! Field("CHTR:CP07:2210:ORDER_OFFL.INPC",16777215,0,"CHTR:CP07:2210:ORDER_OFFL.INPC")
#! Link("CHTR:CP07:2210:ORDER_OFFL.INPC","CHTR:CP07:2210:OFF_CNCL.VAL")
#! Field("CHTR:CP07:2210:ORDER_OFFL.INPB",16777215,0,"CHTR:CP07:2210:ORDER_OFFL.INPB")
#! Link("CHTR:CP07:2210:ORDER_OFFL.INPB","CHTR:CP07:2210:OFF_CFRM.VAL")
#! Field("CHTR:CP07:2210:ORDER_OFFL.VAL",16777215,1,"CHTR:CP07:2210:ORDER_OFFL.VAL")
#! Record("CHTR:CP07:2210:ORDER_OFFT",700,1156,0,0,"CHTR:CP07:2210:ORDER_OFFT")
#! Field("CHTR:CP07:2210:ORDER_OFFT.DOL",16777215,0,"CHTR:CP07:2210:ORDER_OFFT.DOL")
#! Link("CHTR:CP07:2210:ORDER_OFFT.DOL","CHTR:CP07:2210:ORDER_OFFL.VAL")
#! Field("CHTR:CP07:2210:ORDER_OFFT.OUT",16777215,1,"CHTR:CP07:2210:ORDER_OFFT.OUT")
#! Link("CHTR:CP07:2210:ORDER_OFFT.OUT","CHTR:CP07:2210:RQST_OFF.VAL")
#! TextBox(TB1,480,360,780,400,0,"Dialog",12,1,16777215,"Turn On and confirm logic\nTurn Off and confirm logic\n",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "CSV:CP08:4004:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "CSV:CP08:4004:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4004:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "CSV:CP08:4004:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "CSV:CP08:4004:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4004:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.ival")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4004:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.Output")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "CSV:CP08:4004:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) C1SV84004.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "CSV:CP08:4004:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) C1SV84004.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "CSV:CP08:4004:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.MODE")
}

record(bi, "CSV:CP08:4004:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4004:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "CSV:CP08:4004:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) C1SV84004.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "CSV:CP08:4004:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4004:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4004:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.mval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4004:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.Mode_String")
}

record(bi, "CSV:CP08:4004:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.sval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4004:PIDTAG") {
  field(DESC, "SV84004 PIDTAG")
  field(PINI, "YES")
  field(VAL, "C1SV84004")
}

record(bi, "CSV:CP08:4004:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4004:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004O")
  field(ZNAM, "close")
  field(ONAM, "open")
}

record(mbbiDirect, "CSV:CP08:4004:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84004.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("CSV:CP08:4004:MMOD",2500,2499,0,1,"CSV:CP08:4004:MMOD")
#! Record("CSV:CP08:4004:IMOD",2680,2499,0,1,"CSV:CP08:4004:IMOD")
#! Record("CSV:CP08:4004:TEXT1",1760,2682,0,1,"CSV:CP08:4004:TEXT1")
#! Record("CSV:CP08:4004:TEXT2",1760,2782,0,1,"CSV:CP08:4004:TEXT2")
#! Record("CSV:CP08:4004:INTERLOCK",2500,2719,0,1,"CSV:CP08:4004:INTERLOCK")
#! Record("CSV:CP08:4004:IVAL",2140,2499,0,1,"CSV:CP08:4004:IVAL")
#! Record("CSV:CP08:4004:OUTPUT",2680,2279,0,1,"CSV:CP08:4004:OUTPUT")
#! Record("CSV:CP08:4004:MANUAL",1960,2265,0,1,"CSV:CP08:4004:MANUAL")
#! Record("CSV:CP08:4004:SEQUENCER",2140,2265,0,1,"CSV:CP08:4004:SEQUENCER")
#! Record("CSV:CP08:4004:MODE",1760,2274,0,1,"CSV:CP08:4004:MODE")
#! Record("CSV:CP08:4004:ALM",1960,2719,0,1,"CSV:CP08:4004:ALM")
#! Record("CSV:CP08:4004:IL_LATCH",2320,2719,0,1,"CSV:CP08:4004:IL_LATCH")
#! Record("CSV:CP08:4004:IL_RESET",2140,2705,0,1,"CSV:CP08:4004:IL_RESET")
#! Record("CSV:CP08:4004:ZSH",2700,2719,0,1,"CSV:CP08:4004:ZSH")
#! Record("CSV:CP08:4004:ZSL",2880,2719,0,1,"CSV:CP08:4004:ZSL")
#! Record("CSV:CP08:4004:MVAL",2320,2499,0,1,"CSV:CP08:4004:MVAL")
#! Record("CSV:CP08:4004:MODE_STRING",1760,2434,0,1,"CSV:CP08:4004:MODE_STRING")
#! Record("CSV:CP08:4004:SVAL",1960,2499,0,1,"CSV:CP08:4004:SVAL")
#! Record("CSV:CP08:4004:PIDTAG",1760,2582,0,1,"CSV:CP08:4004:PIDTAG")
#! Record("CSV:CP08:4004:SMOD",2864,2499,0,1,"CSV:CP08:4004:SMOD")
#! Record("CSV:CP08:4004:CMD_OUT",2860,2286,0,1,"CSV:CP08:4004:CMD_OUT")
#! Record("CSV:CP08:4004:SWITCH_DISABLE",3060,2720,0,1,"CSV:CP08:4004:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "CSV:CP08:4010:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "CSV:CP08:4010:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4010:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "CSV:CP08:4010:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "CSV:CP08:4010:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4010:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.ival")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4010:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.Output")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "CSV:CP08:4010:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) C1SV84010.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "CSV:CP08:4010:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) C1SV84010.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "CSV:CP08:4010:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.MODE")
}

record(bi, "CSV:CP08:4010:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4010:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "CSV:CP08:4010:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) C1SV84010.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "CSV:CP08:4010:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4010:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4010:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.mval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4010:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.Mode_String")
}

record(bi, "CSV:CP08:4010:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.sval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4010:PIDTAG") {
  field(DESC, "SV84010 PIDTAG")
  field(PINI, "YES")
  field(VAL, "C1SV84010")
}

record(bi, "CSV:CP08:4010:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4010:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010O")
  field(ZNAM, "close")
  field(ONAM, "open")
}

record(mbbiDirect, "CSV:CP08:4010:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C1SV84010.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("CSV:CP08:4010:MMOD",2500,2499,0,1,"CSV:CP08:4010:MMOD")
#! Record("CSV:CP08:4010:IMOD",2680,2499,0,1,"CSV:CP08:4010:IMOD")
#! Record("CSV:CP08:4010:TEXT1",1760,2682,0,1,"CSV:CP08:4010:TEXT1")
#! Record("CSV:CP08:4010:TEXT2",1760,2782,0,1,"CSV:CP08:4010:TEXT2")
#! Record("CSV:CP08:4010:INTERLOCK",2500,2719,0,1,"CSV:CP08:4010:INTERLOCK")
#! Record("CSV:CP08:4010:IVAL",2140,2499,0,1,"CSV:CP08:4010:IVAL")
#! Record("CSV:CP08:4010:OUTPUT",2680,2279,0,1,"CSV:CP08:4010:OUTPUT")
#! Record("CSV:CP08:4010:MANUAL",1960,2265,0,1,"CSV:CP08:4010:MANUAL")
#! Record("CSV:CP08:4010:SEQUENCER",2140,2265,0,1,"CSV:CP08:4010:SEQUENCER")
#! Record("CSV:CP08:4010:MODE",1760,2274,0,1,"CSV:CP08:4010:MODE")
#! Record("CSV:CP08:4010:ALM",1960,2719,0,1,"CSV:CP08:4010:ALM")
#! Record("CSV:CP08:4010:IL_LATCH",2320,2719,0,1,"CSV:CP08:4010:IL_LATCH")
#! Record("CSV:CP08:4010:IL_RESET",2140,2705,0,1,"CSV:CP08:4010:IL_RESET")
#! Record("CSV:CP08:4010:ZSH",2700,2719,0,1,"CSV:CP08:4010:ZSH")
#! Record("CSV:CP08:4010:ZSL",2880,2719,0,1,"CSV:CP08:4010:ZSL")
#! Record("CSV:CP08:4010:MVAL",2320,2499,0,1,"CSV:CP08:4010:MVAL")
#! Record("CSV:CP08:4010:MODE_STRING",1760,2434,0,1,"CSV:CP08:4010:MODE_STRING")
#! Record("CSV:CP08:4010:SVAL",1960,2499,0,1,"CSV:CP08:4010:SVAL")
#! Record("CSV:CP08:4010:PIDTAG",1760,2582,0,1,"CSV:CP08:4010:PIDTAG")
#! Record("CSV:CP08:4010:SMOD",2864,2499,0,1,"CSV:CP08:4010:SMOD")
#! Record("CSV:CP08:4010:CMD_OUT",2860,2286,0,1,"CSV:CP08:4010:CMD_OUT")
#! Record("CSV:CP08:4010:SWITCH_DISABLE",3060,2720,0,1,"CSV:CP08:4010:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "CSV:CP08:4020:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "CSV:CP08:4020:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4020:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "CSV:CP08:4020:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "CSV:CP08:4020:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4020:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.ival")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4020:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.Output")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "CSV:CP08:4020:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) C2SV84020.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "CSV:CP08:4020:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) C2SV84020.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "CSV:CP08:4020:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.MODE")
}

record(bi, "CSV:CP08:4020:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4020:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "CSV:CP08:4020:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) C2SV84020.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "CSV:CP08:4020:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4020:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4020:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.mval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4020:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.Mode_String")
}

record(bi, "CSV:CP08:4020:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.sval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4020:PIDTAG") {
  field(DESC, "SV84020 PIDTAG")
  field(PINI, "YES")
  field(VAL, "C2SV84020")
}

record(bi, "CSV:CP08:4020:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4020:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020O")
  field(ZNAM, "close")
  field(ONAM, "open")
}

record(mbbiDirect, "CSV:CP08:4020:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84020.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("CSV:CP08:4020:MMOD",2500,2499,0,1,"CSV:CP08:4020:MMOD")
#! Record("CSV:CP08:4020:IMOD",2680,2499,0,1,"CSV:CP08:4020:IMOD")
#! Record("CSV:CP08:4020:TEXT1",1760,2682,0,1,"CSV:CP08:4020:TEXT1")
#! Record("CSV:CP08:4020:TEXT2",1760,2782,0,1,"CSV:CP08:4020:TEXT2")
#! Record("CSV:CP08:4020:INTERLOCK",2500,2719,0,1,"CSV:CP08:4020:INTERLOCK")
#! Record("CSV:CP08:4020:IVAL",2140,2499,0,1,"CSV:CP08:4020:IVAL")
#! Record("CSV:CP08:4020:OUTPUT",2680,2279,0,1,"CSV:CP08:4020:OUTPUT")
#! Record("CSV:CP08:4020:MANUAL",1960,2265,0,1,"CSV:CP08:4020:MANUAL")
#! Record("CSV:CP08:4020:SEQUENCER",2140,2265,0,1,"CSV:CP08:4020:SEQUENCER")
#! Record("CSV:CP08:4020:MODE",1760,2274,0,1,"CSV:CP08:4020:MODE")
#! Record("CSV:CP08:4020:ALM",1960,2719,0,1,"CSV:CP08:4020:ALM")
#! Record("CSV:CP08:4020:IL_LATCH",2320,2719,0,1,"CSV:CP08:4020:IL_LATCH")
#! Record("CSV:CP08:4020:IL_RESET",2140,2705,0,1,"CSV:CP08:4020:IL_RESET")
#! Record("CSV:CP08:4020:ZSH",2700,2719,0,1,"CSV:CP08:4020:ZSH")
#! Record("CSV:CP08:4020:ZSL",2880,2719,0,1,"CSV:CP08:4020:ZSL")
#! Record("CSV:CP08:4020:MVAL",2320,2499,0,1,"CSV:CP08:4020:MVAL")
#! Record("CSV:CP08:4020:MODE_STRING",1760,2434,0,1,"CSV:CP08:4020:MODE_STRING")
#! Record("CSV:CP08:4020:SVAL",1960,2499,0,1,"CSV:CP08:4020:SVAL")
#! Record("CSV:CP08:4020:PIDTAG",1760,2582,0,1,"CSV:CP08:4020:PIDTAG")
#! Record("CSV:CP08:4020:SMOD",2864,2499,0,1,"CSV:CP08:4020:SMOD")
#! Record("CSV:CP08:4020:CMD_OUT",2860,2286,0,1,"CSV:CP08:4020:CMD_OUT")
#! Record("CSV:CP08:4020:SWITCH_DISABLE",3060,2720,0,1,"CSV:CP08:4020:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "CSV:CP08:4030:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "CSV:CP08:4030:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4030:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "CSV:CP08:4030:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "CSV:CP08:4030:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4030:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.ival")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4030:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.Output")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "CSV:CP08:4030:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) C2SV84030.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "CSV:CP08:4030:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) C2SV84030.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "CSV:CP08:4030:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.MODE")
}

record(bi, "CSV:CP08:4030:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4030:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "CSV:CP08:4030:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) C2SV84030.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "CSV:CP08:4030:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4030:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4030:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.mval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4030:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.Mode_String")
}

record(bi, "CSV:CP08:4030:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.sval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4030:PIDTAG") {
  field(DESC, "SV84030 PIDTAG")
  field(PINI, "YES")
  field(VAL, "C2SV84030")
}

record(bi, "CSV:CP08:4030:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4030:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030O")
  field(ZNAM, "close")
  field(ONAM, "open")
}

record(mbbiDirect, "CSV:CP08:4030:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) C2SV84030.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("CSV:CP08:4030:MMOD",2500,2499,0,1,"CSV:CP08:4030:MMOD")
#! Record("CSV:CP08:4030:IMOD",2680,2499,0,1,"CSV:CP08:4030:IMOD")
#! Record("CSV:CP08:4030:TEXT1",1760,2682,0,1,"CSV:CP08:4030:TEXT1")
#! Record("CSV:CP08:4030:TEXT2",1760,2782,0,1,"CSV:CP08:4030:TEXT2")
#! Record("CSV:CP08:4030:INTERLOCK",2500,2719,0,1,"CSV:CP08:4030:INTERLOCK")
#! Record("CSV:CP08:4030:IVAL",2140,2499,0,1,"CSV:CP08:4030:IVAL")
#! Record("CSV:CP08:4030:OUTPUT",2680,2279,0,1,"CSV:CP08:4030:OUTPUT")
#! Record("CSV:CP08:4030:MANUAL",1960,2265,0,1,"CSV:CP08:4030:MANUAL")
#! Record("CSV:CP08:4030:SEQUENCER",2140,2265,0,1,"CSV:CP08:4030:SEQUENCER")
#! Record("CSV:CP08:4030:MODE",1760,2274,0,1,"CSV:CP08:4030:MODE")
#! Record("CSV:CP08:4030:ALM",1960,2719,0,1,"CSV:CP08:4030:ALM")
#! Record("CSV:CP08:4030:IL_LATCH",2320,2719,0,1,"CSV:CP08:4030:IL_LATCH")
#! Record("CSV:CP08:4030:IL_RESET",2140,2705,0,1,"CSV:CP08:4030:IL_RESET")
#! Record("CSV:CP08:4030:ZSH",2700,2719,0,1,"CSV:CP08:4030:ZSH")
#! Record("CSV:CP08:4030:ZSL",2880,2719,0,1,"CSV:CP08:4030:ZSL")
#! Record("CSV:CP08:4030:MVAL",2320,2499,0,1,"CSV:CP08:4030:MVAL")
#! Record("CSV:CP08:4030:MODE_STRING",1760,2434,0,1,"CSV:CP08:4030:MODE_STRING")
#! Record("CSV:CP08:4030:SVAL",1960,2499,0,1,"CSV:CP08:4030:SVAL")
#! Record("CSV:CP08:4030:PIDTAG",1760,2582,0,1,"CSV:CP08:4030:PIDTAG")
#! Record("CSV:CP08:4030:SMOD",2864,2499,0,1,"CSV:CP08:4030:SMOD")
#! Record("CSV:CP08:4030:CMD_OUT",2860,2286,0,1,"CSV:CP08:4030:CMD_OUT")
#! Record("CSV:CP08:4030:SWITCH_DISABLE",3060,2720,0,1,"CSV:CP08:4030:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "CSV:CP08:4110:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "CSV:CP08:4110:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4110:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "CSV:CP08:4110:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "CSV:CP08:4110:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4110:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.ival")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4110:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.Output")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "CSV:CP08:4110:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CSV84110.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "CSV:CP08:4110:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CSV84110.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "CSV:CP08:4110:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.MODE")
}

record(bi, "CSV:CP08:4110:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4110:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "CSV:CP08:4110:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CSV84110.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "CSV:CP08:4110:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4110:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4110:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.mval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4110:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.Mode_String")
}

record(bi, "CSV:CP08:4110:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.sval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4110:PIDTAG") {
  field(DESC, "SV84110 PIDTAG")
  field(PINI, "YES")
  field(VAL, "CSV84110")
}

record(bi, "CSV:CP08:4110:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4110:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110O")
  field(ZNAM, "close")
  field(ONAM, "open")
}

record(mbbiDirect, "CSV:CP08:4110:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84110.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("CSV:CP08:4110:MMOD",2500,2499,0,1,"CSV:CP08:4110:MMOD")
#! Record("CSV:CP08:4110:IMOD",2680,2499,0,1,"CSV:CP08:4110:IMOD")
#! Record("CSV:CP08:4110:TEXT1",1760,2682,0,1,"CSV:CP08:4110:TEXT1")
#! Record("CSV:CP08:4110:TEXT2",1760,2782,0,1,"CSV:CP08:4110:TEXT2")
#! Record("CSV:CP08:4110:INTERLOCK",2500,2719,0,1,"CSV:CP08:4110:INTERLOCK")
#! Record("CSV:CP08:4110:IVAL",2140,2499,0,1,"CSV:CP08:4110:IVAL")
#! Record("CSV:CP08:4110:OUTPUT",2680,2279,0,1,"CSV:CP08:4110:OUTPUT")
#! Record("CSV:CP08:4110:MANUAL",1960,2265,0,1,"CSV:CP08:4110:MANUAL")
#! Record("CSV:CP08:4110:SEQUENCER",2140,2265,0,1,"CSV:CP08:4110:SEQUENCER")
#! Record("CSV:CP08:4110:MODE",1760,2274,0,1,"CSV:CP08:4110:MODE")
#! Record("CSV:CP08:4110:ALM",1960,2719,0,1,"CSV:CP08:4110:ALM")
#! Record("CSV:CP08:4110:IL_LATCH",2320,2719,0,1,"CSV:CP08:4110:IL_LATCH")
#! Record("CSV:CP08:4110:IL_RESET",2140,2705,0,1,"CSV:CP08:4110:IL_RESET")
#! Record("CSV:CP08:4110:ZSH",2700,2719,0,1,"CSV:CP08:4110:ZSH")
#! Record("CSV:CP08:4110:ZSL",2880,2719,0,1,"CSV:CP08:4110:ZSL")
#! Record("CSV:CP08:4110:MVAL",2320,2499,0,1,"CSV:CP08:4110:MVAL")
#! Record("CSV:CP08:4110:MODE_STRING",1760,2434,0,1,"CSV:CP08:4110:MODE_STRING")
#! Record("CSV:CP08:4110:SVAL",1960,2499,0,1,"CSV:CP08:4110:SVAL")
#! Record("CSV:CP08:4110:PIDTAG",1760,2582,0,1,"CSV:CP08:4110:PIDTAG")
#! Record("CSV:CP08:4110:SMOD",2864,2499,0,1,"CSV:CP08:4110:SMOD")
#! Record("CSV:CP08:4110:CMD_OUT",2860,2286,0,1,"CSV:CP08:4110:CMD_OUT")
#! Record("CSV:CP08:4110:SWITCH_DISABLE",3060,2720,0,1,"CSV:CP08:4110:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "CSV:CP08:4113:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "CSV:CP08:4113:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4113:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "CSV:CP08:4113:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "CSV:CP08:4113:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4113:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.ival")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4113:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.Output")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "CSV:CP08:4113:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CSV84113.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "CSV:CP08:4113:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CSV84113.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "CSV:CP08:4113:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.MODE")
}

record(bi, "CSV:CP08:4113:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4113:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "CSV:CP08:4113:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CSV84113.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "CSV:CP08:4113:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4113:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4113:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.mval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4113:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.Mode_String")
}

record(bi, "CSV:CP08:4113:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.sval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4113:PIDTAG") {
  field(DESC, "SV84113 PIDTAG")
  field(PINI, "YES")
  field(VAL, "CSV84113")
}

record(bi, "CSV:CP08:4113:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4113:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113O")
  field(ZNAM, "close")
  field(ONAM, "open")
}

record(mbbiDirect, "CSV:CP08:4113:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84113.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("CSV:CP08:4113:MMOD",2500,2499,0,1,"CSV:CP08:4113:MMOD")
#! Record("CSV:CP08:4113:IMOD",2680,2499,0,1,"CSV:CP08:4113:IMOD")
#! Record("CSV:CP08:4113:TEXT1",1760,2682,0,1,"CSV:CP08:4113:TEXT1")
#! Record("CSV:CP08:4113:TEXT2",1760,2782,0,1,"CSV:CP08:4113:TEXT2")
#! Record("CSV:CP08:4113:INTERLOCK",2500,2719,0,1,"CSV:CP08:4113:INTERLOCK")
#! Record("CSV:CP08:4113:IVAL",2140,2499,0,1,"CSV:CP08:4113:IVAL")
#! Record("CSV:CP08:4113:OUTPUT",2680,2279,0,1,"CSV:CP08:4113:OUTPUT")
#! Record("CSV:CP08:4113:MANUAL",1960,2265,0,1,"CSV:CP08:4113:MANUAL")
#! Record("CSV:CP08:4113:SEQUENCER",2140,2265,0,1,"CSV:CP08:4113:SEQUENCER")
#! Record("CSV:CP08:4113:MODE",1760,2274,0,1,"CSV:CP08:4113:MODE")
#! Record("CSV:CP08:4113:ALM",1960,2719,0,1,"CSV:CP08:4113:ALM")
#! Record("CSV:CP08:4113:IL_LATCH",2320,2719,0,1,"CSV:CP08:4113:IL_LATCH")
#! Record("CSV:CP08:4113:IL_RESET",2140,2705,0,1,"CSV:CP08:4113:IL_RESET")
#! Record("CSV:CP08:4113:ZSH",2700,2719,0,1,"CSV:CP08:4113:ZSH")
#! Record("CSV:CP08:4113:ZSL",2880,2719,0,1,"CSV:CP08:4113:ZSL")
#! Record("CSV:CP08:4113:MVAL",2320,2499,0,1,"CSV:CP08:4113:MVAL")
#! Record("CSV:CP08:4113:MODE_STRING",1760,2434,0,1,"CSV:CP08:4113:MODE_STRING")
#! Record("CSV:CP08:4113:SVAL",1960,2499,0,1,"CSV:CP08:4113:SVAL")
#! Record("CSV:CP08:4113:PIDTAG",1760,2582,0,1,"CSV:CP08:4113:PIDTAG")
#! Record("CSV:CP08:4113:SMOD",2864,2499,0,1,"CSV:CP08:4113:SMOD")
#! Record("CSV:CP08:4113:CMD_OUT",2860,2286,0,1,"CSV:CP08:4113:CMD_OUT")
#! Record("CSV:CP08:4113:SWITCH_DISABLE",3060,2720,0,1,"CSV:CP08:4113:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "CSV:CP08:4210:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "CSV:CP08:4210:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4210:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "CSV:CP08:4210:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "CSV:CP08:4210:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4210:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.ival")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4210:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.Output")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "CSV:CP08:4210:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CSV84210.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "CSV:CP08:4210:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CSV84210.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "CSV:CP08:4210:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.MODE")
}

record(bi, "CSV:CP08:4210:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4210:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "CSV:CP08:4210:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CSV84210.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "CSV:CP08:4210:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4210:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4210:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.mval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4210:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.Mode_String")
}

record(bi, "CSV:CP08:4210:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.sval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4210:PIDTAG") {
  field(DESC, "SV84210 PIDTAG")
  field(PINI, "YES")
  field(VAL, "CSV84210")
}

record(bi, "CSV:CP08:4210:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4210:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210O")
  field(ZNAM, "close")
  field(ONAM, "open")
}

record(mbbiDirect, "CSV:CP08:4210:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84210.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("CSV:CP08:4210:MMOD",2500,2499,0,1,"CSV:CP08:4210:MMOD")
#! Record("CSV:CP08:4210:IMOD",2680,2499,0,1,"CSV:CP08:4210:IMOD")
#! Record("CSV:CP08:4210:TEXT1",1760,2682,0,1,"CSV:CP08:4210:TEXT1")
#! Record("CSV:CP08:4210:TEXT2",1760,2782,0,1,"CSV:CP08:4210:TEXT2")
#! Record("CSV:CP08:4210:INTERLOCK",2500,2719,0,1,"CSV:CP08:4210:INTERLOCK")
#! Record("CSV:CP08:4210:IVAL",2140,2499,0,1,"CSV:CP08:4210:IVAL")
#! Record("CSV:CP08:4210:OUTPUT",2680,2279,0,1,"CSV:CP08:4210:OUTPUT")
#! Record("CSV:CP08:4210:MANUAL",1960,2265,0,1,"CSV:CP08:4210:MANUAL")
#! Record("CSV:CP08:4210:SEQUENCER",2140,2265,0,1,"CSV:CP08:4210:SEQUENCER")
#! Record("CSV:CP08:4210:MODE",1760,2274,0,1,"CSV:CP08:4210:MODE")
#! Record("CSV:CP08:4210:ALM",1960,2719,0,1,"CSV:CP08:4210:ALM")
#! Record("CSV:CP08:4210:IL_LATCH",2320,2719,0,1,"CSV:CP08:4210:IL_LATCH")
#! Record("CSV:CP08:4210:IL_RESET",2140,2705,0,1,"CSV:CP08:4210:IL_RESET")
#! Record("CSV:CP08:4210:ZSH",2700,2719,0,1,"CSV:CP08:4210:ZSH")
#! Record("CSV:CP08:4210:ZSL",2880,2719,0,1,"CSV:CP08:4210:ZSL")
#! Record("CSV:CP08:4210:MVAL",2320,2499,0,1,"CSV:CP08:4210:MVAL")
#! Record("CSV:CP08:4210:MODE_STRING",1760,2434,0,1,"CSV:CP08:4210:MODE_STRING")
#! Record("CSV:CP08:4210:SVAL",1960,2499,0,1,"CSV:CP08:4210:SVAL")
#! Record("CSV:CP08:4210:PIDTAG",1760,2582,0,1,"CSV:CP08:4210:PIDTAG")
#! Record("CSV:CP08:4210:SMOD",2864,2499,0,1,"CSV:CP08:4210:SMOD")
#! Record("CSV:CP08:4210:CMD_OUT",2860,2286,0,1,"CSV:CP08:4210:CMD_OUT")
#! Record("CSV:CP08:4210:SWITCH_DISABLE",3060,2720,0,1,"CSV:CP08:4210:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "CSV:CP08:4213:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "CSV:CP08:4213:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4213:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "CSV:CP08:4213:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "CSV:CP08:4213:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4213:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.ival")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4213:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.Output")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "CSV:CP08:4213:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CSV84213.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "CSV:CP08:4213:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CSV84213.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "CSV:CP08:4213:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.MODE")
}

record(bi, "CSV:CP08:4213:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4213:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "CSV:CP08:4213:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CSV84213.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "CSV:CP08:4213:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4213:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4213:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.mval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4213:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.Mode_String")
}

record(bi, "CSV:CP08:4213:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.sval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CSV:CP08:4213:PIDTAG") {
  field(DESC, "SV84213 PIDTAG")
  field(PINI, "YES")
  field(VAL, "CSV84213")
}

record(bi, "CSV:CP08:4213:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CSV:CP08:4213:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213O")
  field(ZNAM, "close")
  field(ONAM, "open")
}

record(mbbiDirect, "CSV:CP08:4213:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CSV84213.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("CSV:CP08:4213:MMOD",2500,2499,0,1,"CSV:CP08:4213:MMOD")
#! Record("CSV:CP08:4213:IMOD",2680,2499,0,1,"CSV:CP08:4213:IMOD")
#! Record("CSV:CP08:4213:TEXT1",1760,2682,0,1,"CSV:CP08:4213:TEXT1")
#! Record("CSV:CP08:4213:TEXT2",1760,2782,0,1,"CSV:CP08:4213:TEXT2")
#! Record("CSV:CP08:4213:INTERLOCK",2500,2719,0,1,"CSV:CP08:4213:INTERLOCK")
#! Record("CSV:CP08:4213:IVAL",2140,2499,0,1,"CSV:CP08:4213:IVAL")
#! Record("CSV:CP08:4213:OUTPUT",2680,2279,0,1,"CSV:CP08:4213:OUTPUT")
#! Record("CSV:CP08:4213:MANUAL",1960,2265,0,1,"CSV:CP08:4213:MANUAL")
#! Record("CSV:CP08:4213:SEQUENCER",2140,2265,0,1,"CSV:CP08:4213:SEQUENCER")
#! Record("CSV:CP08:4213:MODE",1760,2274,0,1,"CSV:CP08:4213:MODE")
#! Record("CSV:CP08:4213:ALM",1960,2719,0,1,"CSV:CP08:4213:ALM")
#! Record("CSV:CP08:4213:IL_LATCH",2320,2719,0,1,"CSV:CP08:4213:IL_LATCH")
#! Record("CSV:CP08:4213:IL_RESET",2140,2705,0,1,"CSV:CP08:4213:IL_RESET")
#! Record("CSV:CP08:4213:ZSH",2700,2719,0,1,"CSV:CP08:4213:ZSH")
#! Record("CSV:CP08:4213:ZSL",2880,2719,0,1,"CSV:CP08:4213:ZSL")
#! Record("CSV:CP08:4213:MVAL",2320,2499,0,1,"CSV:CP08:4213:MVAL")
#! Record("CSV:CP08:4213:MODE_STRING",1760,2434,0,1,"CSV:CP08:4213:MODE_STRING")
#! Record("CSV:CP08:4213:SVAL",1960,2499,0,1,"CSV:CP08:4213:SVAL")
#! Record("CSV:CP08:4213:PIDTAG",1760,2582,0,1,"CSV:CP08:4213:PIDTAG")
#! Record("CSV:CP08:4213:SMOD",2864,2499,0,1,"CSV:CP08:4213:SMOD")
#! Record("CSV:CP08:4213:CMD_OUT",2860,2286,0,1,"CSV:CP08:4213:CMD_OUT")
#! Record("CSV:CP08:4213:SWITCH_DISABLE",3060,2720,0,1,"CSV:CP08:4213:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "CHTR:CP07:2110:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "CHTR:CP07:2110:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CHTR:CP07:2110:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "CHTR:CP07:2110:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "CHTR:CP07:2110:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CHTR:CP07:2110:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.ival")
  field(ZNAM, "off")
  field(ONAM, "on")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CHTR:CP07:2110:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.Output")
  field(ZNAM, "off")
  field(ONAM, "on")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "CHTR:CP07:2110:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CHTR72110.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "CHTR:CP07:2110:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CHTR72110.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "CHTR:CP07:2110:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.MODE")
}

record(bi, "CHTR:CP07:2110:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CHTR:CP07:2110:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "CHTR:CP07:2110:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CHTR72110.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "CHTR:CP07:2110:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CHTR:CP07:2110:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CHTR:CP07:2110:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.mval")
  field(ZNAM, "off")
  field(ONAM, "on")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CHTR:CP07:2110:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.Mode_String")
}

record(bi, "CHTR:CP07:2110:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.sval")
  field(ZNAM, "off")
  field(ONAM, "on")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CHTR:CP07:2110:PIDTAG") {
  field(DESC, "CHTR72110 PIDTAG")
  field(PINI, "YES")
  field(VAL, "CHTR72110")
}

record(bi, "CHTR:CP07:2110:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CHTR:CP07:2110:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110O")
  field(ZNAM, "off")
  field(ONAM, "on")
}

record(mbbiDirect, "CHTR:CP07:2110:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72110.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("CHTR:CP07:2110:MMOD",2500,2499,0,1,"CHTR:CP07:2110:MMOD")
#! Record("CHTR:CP07:2110:IMOD",2680,2499,0,1,"CHTR:CP07:2110:IMOD")
#! Record("CHTR:CP07:2110:TEXT1",1760,2682,0,1,"CHTR:CP07:2110:TEXT1")
#! Record("CHTR:CP07:2110:TEXT2",1760,2782,0,1,"CHTR:CP07:2110:TEXT2")
#! Record("CHTR:CP07:2110:INTERLOCK",2500,2719,0,1,"CHTR:CP07:2110:INTERLOCK")
#! Record("CHTR:CP07:2110:IVAL",2140,2499,0,1,"CHTR:CP07:2110:IVAL")
#! Record("CHTR:CP07:2110:OUTPUT",2680,2279,0,1,"CHTR:CP07:2110:OUTPUT")
#! Record("CHTR:CP07:2110:MANUAL",1960,2265,0,1,"CHTR:CP07:2110:MANUAL")
#! Record("CHTR:CP07:2110:SEQUENCER",2140,2265,0,1,"CHTR:CP07:2110:SEQUENCER")
#! Record("CHTR:CP07:2110:MODE",1760,2274,0,1,"CHTR:CP07:2110:MODE")
#! Record("CHTR:CP07:2110:ALM",1960,2719,0,1,"CHTR:CP07:2110:ALM")
#! Record("CHTR:CP07:2110:IL_LATCH",2320,2719,0,1,"CHTR:CP07:2110:IL_LATCH")
#! Record("CHTR:CP07:2110:IL_RESET",2140,2705,0,1,"CHTR:CP07:2110:IL_RESET")
#! Record("CHTR:CP07:2110:ZSH",2700,2719,0,1,"CHTR:CP07:2110:ZSH")
#! Record("CHTR:CP07:2110:ZSL",2880,2719,0,1,"CHTR:CP07:2110:ZSL")
#! Record("CHTR:CP07:2110:MVAL",2320,2499,0,1,"CHTR:CP07:2110:MVAL")
#! Record("CHTR:CP07:2110:MODE_STRING",1760,2434,0,1,"CHTR:CP07:2110:MODE_STRING")
#! Record("CHTR:CP07:2110:SVAL",1960,2499,0,1,"CHTR:CP07:2110:SVAL")
#! Record("CHTR:CP07:2110:PIDTAG",1760,2582,0,1,"CHTR:CP07:2110:PIDTAG")
#! Record("CHTR:CP07:2110:SMOD",2864,2499,0,1,"CHTR:CP07:2110:SMOD")
#! Record("CHTR:CP07:2110:CMD_OUT",2860,2286,0,1,"CHTR:CP07:2110:CMD_OUT")
#! Record("CHTR:CP07:2110:SWITCH_DISABLE",3060,2720,0,1,"CHTR:CP07:2110:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "RCMP:CP07:21:L:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "RCMP:CP07:21:L:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "RCMP:CP07:21:L:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "RCMP:CP07:21:L:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "RCMP:CP07:21:L:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:21:L:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.ival")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:21:L:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.Output")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "RCMP:CP07:21:L:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CMP721_LD.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "RCMP:CP07:21:L:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CMP721_LD.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "RCMP:CP07:21:L:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.MODE")
}

record(bi, "RCMP:CP07:21:L:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:21:L:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "RCMP:CP07:21:L:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CMP721_LD.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "RCMP:CP07:21:L:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:21:L:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:21:L:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.mval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "RCMP:CP07:21:L:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.Mode_String")
}

record(bi, "RCMP:CP07:21:L:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.sval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "RCMP:CP07:21:L:PIDTAG") {
  field(DESC, "RCMP721 Load PIDTAG")
  field(PINI, "YES")
  field(VAL, "CCMP721LD")
}

record(bi, "RCMP:CP07:21:L:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:21:L:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LDO")
  field(ZNAM, "close")
  field(ONAM, "open")
}

record(mbbiDirect, "RCMP:CP07:21:L:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_LD.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("RCMP:CP07:21:L:MMOD",2500,2499,0,1,"RCMP:CP07:21:L:MMOD")
#! Record("RCMP:CP07:21:L:IMOD",2680,2499,0,1,"RCMP:CP07:21:L:IMOD")
#! Record("RCMP:CP07:21:L:TEXT1",1760,2682,0,1,"RCMP:CP07:21:L:TEXT1")
#! Record("RCMP:CP07:21:L:TEXT2",1760,2782,0,1,"RCMP:CP07:21:L:TEXT2")
#! Record("RCMP:CP07:21:L:INTERLOCK",2500,2719,0,1,"RCMP:CP07:21:L:INTERLOCK")
#! Record("RCMP:CP07:21:L:IVAL",2140,2499,0,1,"RCMP:CP07:21:L:IVAL")
#! Record("RCMP:CP07:21:L:OUTPUT",2680,2279,0,1,"RCMP:CP07:21:L:OUTPUT")
#! Record("RCMP:CP07:21:L:MANUAL",1960,2265,0,1,"RCMP:CP07:21:L:MANUAL")
#! Record("RCMP:CP07:21:L:SEQUENCER",2140,2265,0,1,"RCMP:CP07:21:L:SEQUENCER")
#! Record("RCMP:CP07:21:L:MODE",1760,2274,0,1,"RCMP:CP07:21:L:MODE")
#! Record("RCMP:CP07:21:L:ALM",1960,2719,0,1,"RCMP:CP07:21:L:ALM")
#! Record("RCMP:CP07:21:L:IL_LATCH",2320,2719,0,1,"RCMP:CP07:21:L:IL_LATCH")
#! Record("RCMP:CP07:21:L:IL_RESET",2140,2705,0,1,"RCMP:CP07:21:L:IL_RESET")
#! Record("RCMP:CP07:21:L:ZSH",2700,2719,0,1,"RCMP:CP07:21:L:ZSH")
#! Record("RCMP:CP07:21:L:ZSL",2880,2719,0,1,"RCMP:CP07:21:L:ZSL")
#! Record("RCMP:CP07:21:L:MVAL",2320,2499,0,1,"RCMP:CP07:21:L:MVAL")
#! Record("RCMP:CP07:21:L:MODE_STRING",1760,2434,0,1,"RCMP:CP07:21:L:MODE_STRING")
#! Record("RCMP:CP07:21:L:SVAL",1960,2499,0,1,"RCMP:CP07:21:L:SVAL")
#! Record("RCMP:CP07:21:L:PIDTAG",1760,2582,0,1,"RCMP:CP07:21:L:PIDTAG")
#! Record("RCMP:CP07:21:L:SMOD",2864,2499,0,1,"RCMP:CP07:21:L:SMOD")
#! Record("RCMP:CP07:21:L:CMD_OUT",2860,2286,0,1,"RCMP:CP07:21:L:CMD_OUT")
#! Record("RCMP:CP07:21:L:SWITCH_DISABLE",3060,2720,0,1,"RCMP:CP07:21:L:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "RCMP:CP07:21:U:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "RCMP:CP07:21:U:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "RCMP:CP07:21:U:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "RCMP:CP07:21:U:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "RCMP:CP07:21:U:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:21:U:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.ival")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:21:U:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.Output")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "RCMP:CP07:21:U:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CMP721_UL.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "RCMP:CP07:21:U:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CMP721_UL.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "RCMP:CP07:21:U:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.MODE")
}

record(bi, "RCMP:CP07:21:U:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:21:U:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "RCMP:CP07:21:U:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CMP721_UL.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "RCMP:CP07:21:U:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:21:U:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:21:U:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.mval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "RCMP:CP07:21:U:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.Mode_String")
}

record(bi, "RCMP:CP07:21:U:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.sval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "RCMP:CP07:21:U:PIDTAG") {
  field(DESC, "RCMP721 Unload PIDTAG")
  field(PINI, "YES")
  field(VAL, "CCMP721UL")
}

record(bi, "RCMP:CP07:21:U:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:21:U:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_ULO")
  field(ZNAM, "close")
  field(ONAM, "open")
}

record(mbbiDirect, "RCMP:CP07:21:U:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP721_UL.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("RCMP:CP07:21:U:MMOD",2500,2499,0,1,"RCMP:CP07:21:U:MMOD")
#! Record("RCMP:CP07:21:U:IMOD",2680,2499,0,1,"RCMP:CP07:21:U:IMOD")
#! Record("RCMP:CP07:21:U:TEXT1",1760,2682,0,1,"RCMP:CP07:21:U:TEXT1")
#! Record("RCMP:CP07:21:U:TEXT2",1760,2782,0,1,"RCMP:CP07:21:U:TEXT2")
#! Record("RCMP:CP07:21:U:INTERLOCK",2500,2719,0,1,"RCMP:CP07:21:U:INTERLOCK")
#! Record("RCMP:CP07:21:U:IVAL",2140,2499,0,1,"RCMP:CP07:21:U:IVAL")
#! Record("RCMP:CP07:21:U:OUTPUT",2680,2279,0,1,"RCMP:CP07:21:U:OUTPUT")
#! Record("RCMP:CP07:21:U:MANUAL",1960,2265,0,1,"RCMP:CP07:21:U:MANUAL")
#! Record("RCMP:CP07:21:U:SEQUENCER",2140,2265,0,1,"RCMP:CP07:21:U:SEQUENCER")
#! Record("RCMP:CP07:21:U:MODE",1760,2274,0,1,"RCMP:CP07:21:U:MODE")
#! Record("RCMP:CP07:21:U:ALM",1960,2719,0,1,"RCMP:CP07:21:U:ALM")
#! Record("RCMP:CP07:21:U:IL_LATCH",2320,2719,0,1,"RCMP:CP07:21:U:IL_LATCH")
#! Record("RCMP:CP07:21:U:IL_RESET",2140,2705,0,1,"RCMP:CP07:21:U:IL_RESET")
#! Record("RCMP:CP07:21:U:ZSH",2700,2719,0,1,"RCMP:CP07:21:U:ZSH")
#! Record("RCMP:CP07:21:U:ZSL",2880,2719,0,1,"RCMP:CP07:21:U:ZSL")
#! Record("RCMP:CP07:21:U:MVAL",2320,2499,0,1,"RCMP:CP07:21:U:MVAL")
#! Record("RCMP:CP07:21:U:MODE_STRING",1760,2434,0,1,"RCMP:CP07:21:U:MODE_STRING")
#! Record("RCMP:CP07:21:U:SVAL",1960,2499,0,1,"RCMP:CP07:21:U:SVAL")
#! Record("RCMP:CP07:21:U:PIDTAG",1760,2582,0,1,"RCMP:CP07:21:U:PIDTAG")
#! Record("RCMP:CP07:21:U:SMOD",2864,2499,0,1,"RCMP:CP07:21:U:SMOD")
#! Record("RCMP:CP07:21:U:CMD_OUT",2860,2286,0,1,"RCMP:CP07:21:U:CMD_OUT")
#! Record("RCMP:CP07:21:U:SWITCH_DISABLE",3060,2720,0,1,"RCMP:CP07:21:U:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "CHTR:CP07:2210:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "CHTR:CP07:2210:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CHTR:CP07:2210:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "CHTR:CP07:2210:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "CHTR:CP07:2210:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CHTR:CP07:2210:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.ival")
  field(ZNAM, "off")
  field(ONAM, "on")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CHTR:CP07:2210:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.Output")
  field(ZNAM, "off")
  field(ONAM, "on")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "CHTR:CP07:2210:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CHTR72210.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "CHTR:CP07:2210:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CHTR72210.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "CHTR:CP07:2210:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.MODE")
}

record(bi, "CHTR:CP07:2210:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CHTR:CP07:2210:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "CHTR:CP07:2210:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CHTR72210.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "CHTR:CP07:2210:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CHTR:CP07:2210:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CHTR:CP07:2210:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.mval")
  field(ZNAM, "off")
  field(ONAM, "on")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CHTR:CP07:2210:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.Mode_String")
}

record(bi, "CHTR:CP07:2210:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.sval")
  field(ZNAM, "off")
  field(ONAM, "on")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "CHTR:CP07:2210:PIDTAG") {
  field(DESC, "CHTR72210 PIDTAG")
  field(PINI, "YES")
  field(VAL, "CHTR72210")
}

record(bi, "CHTR:CP07:2210:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "CHTR:CP07:2210:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210O")
  field(ZNAM, "off")
  field(ONAM, "on")
}

record(mbbiDirect, "CHTR:CP07:2210:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CHTR72210.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("CHTR:CP07:2210:MMOD",2500,2499,0,1,"CHTR:CP07:2210:MMOD")
#! Record("CHTR:CP07:2210:IMOD",2680,2499,0,1,"CHTR:CP07:2210:IMOD")
#! Record("CHTR:CP07:2210:TEXT1",1760,2682,0,1,"CHTR:CP07:2210:TEXT1")
#! Record("CHTR:CP07:2210:TEXT2",1760,2782,0,1,"CHTR:CP07:2210:TEXT2")
#! Record("CHTR:CP07:2210:INTERLOCK",2500,2719,0,1,"CHTR:CP07:2210:INTERLOCK")
#! Record("CHTR:CP07:2210:IVAL",2140,2499,0,1,"CHTR:CP07:2210:IVAL")
#! Record("CHTR:CP07:2210:OUTPUT",2680,2279,0,1,"CHTR:CP07:2210:OUTPUT")
#! Record("CHTR:CP07:2210:MANUAL",1960,2265,0,1,"CHTR:CP07:2210:MANUAL")
#! Record("CHTR:CP07:2210:SEQUENCER",2140,2265,0,1,"CHTR:CP07:2210:SEQUENCER")
#! Record("CHTR:CP07:2210:MODE",1760,2274,0,1,"CHTR:CP07:2210:MODE")
#! Record("CHTR:CP07:2210:ALM",1960,2719,0,1,"CHTR:CP07:2210:ALM")
#! Record("CHTR:CP07:2210:IL_LATCH",2320,2719,0,1,"CHTR:CP07:2210:IL_LATCH")
#! Record("CHTR:CP07:2210:IL_RESET",2140,2705,0,1,"CHTR:CP07:2210:IL_RESET")
#! Record("CHTR:CP07:2210:ZSH",2700,2719,0,1,"CHTR:CP07:2210:ZSH")
#! Record("CHTR:CP07:2210:ZSL",2880,2719,0,1,"CHTR:CP07:2210:ZSL")
#! Record("CHTR:CP07:2210:MVAL",2320,2499,0,1,"CHTR:CP07:2210:MVAL")
#! Record("CHTR:CP07:2210:MODE_STRING",1760,2434,0,1,"CHTR:CP07:2210:MODE_STRING")
#! Record("CHTR:CP07:2210:SVAL",1960,2499,0,1,"CHTR:CP07:2210:SVAL")
#! Record("CHTR:CP07:2210:PIDTAG",1760,2582,0,1,"CHTR:CP07:2210:PIDTAG")
#! Record("CHTR:CP07:2210:SMOD",2864,2499,0,1,"CHTR:CP07:2210:SMOD")
#! Record("CHTR:CP07:2210:CMD_OUT",2860,2286,0,1,"CHTR:CP07:2210:CMD_OUT")
#! Record("CHTR:CP07:2210:SWITCH_DISABLE",3060,2720,0,1,"CHTR:CP07:2210:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "RCMP:CP07:22:L:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "RCMP:CP07:22:L:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "RCMP:CP07:22:L:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "RCMP:CP07:22:L:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "RCMP:CP07:22:L:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:22:L:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.ival")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:22:L:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.Output")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "RCMP:CP07:22:L:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CMP722_LD.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "RCMP:CP07:22:L:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CMP722_LD.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "RCMP:CP07:22:L:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.MODE")
}

record(bi, "RCMP:CP07:22:L:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:22:L:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "RCMP:CP07:22:L:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CMP722_LD.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "RCMP:CP07:22:L:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:22:L:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:22:L:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.mval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "RCMP:CP07:22:L:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.Mode_String")
}

record(bi, "RCMP:CP07:22:L:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.sval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "RCMP:CP07:22:L:PIDTAG") {
  field(DESC, "RCMP722 Load PIDTAG")
  field(PINI, "YES")
  field(VAL, "CCMP722LD")
}

record(bi, "RCMP:CP07:22:L:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:22:L:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LDO")
  field(ZNAM, "close")
  field(ONAM, "open")
}

record(mbbiDirect, "RCMP:CP07:22:L:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_LD.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("RCMP:CP07:22:L:MMOD",2500,2499,0,1,"RCMP:CP07:22:L:MMOD")
#! Record("RCMP:CP07:22:L:IMOD",2680,2499,0,1,"RCMP:CP07:22:L:IMOD")
#! Record("RCMP:CP07:22:L:TEXT1",1760,2682,0,1,"RCMP:CP07:22:L:TEXT1")
#! Record("RCMP:CP07:22:L:TEXT2",1760,2782,0,1,"RCMP:CP07:22:L:TEXT2")
#! Record("RCMP:CP07:22:L:INTERLOCK",2500,2719,0,1,"RCMP:CP07:22:L:INTERLOCK")
#! Record("RCMP:CP07:22:L:IVAL",2140,2499,0,1,"RCMP:CP07:22:L:IVAL")
#! Record("RCMP:CP07:22:L:OUTPUT",2680,2279,0,1,"RCMP:CP07:22:L:OUTPUT")
#! Record("RCMP:CP07:22:L:MANUAL",1960,2265,0,1,"RCMP:CP07:22:L:MANUAL")
#! Record("RCMP:CP07:22:L:SEQUENCER",2140,2265,0,1,"RCMP:CP07:22:L:SEQUENCER")
#! Record("RCMP:CP07:22:L:MODE",1760,2274,0,1,"RCMP:CP07:22:L:MODE")
#! Record("RCMP:CP07:22:L:ALM",1960,2719,0,1,"RCMP:CP07:22:L:ALM")
#! Record("RCMP:CP07:22:L:IL_LATCH",2320,2719,0,1,"RCMP:CP07:22:L:IL_LATCH")
#! Record("RCMP:CP07:22:L:IL_RESET",2140,2705,0,1,"RCMP:CP07:22:L:IL_RESET")
#! Record("RCMP:CP07:22:L:ZSH",2700,2719,0,1,"RCMP:CP07:22:L:ZSH")
#! Record("RCMP:CP07:22:L:ZSL",2880,2719,0,1,"RCMP:CP07:22:L:ZSL")
#! Record("RCMP:CP07:22:L:MVAL",2320,2499,0,1,"RCMP:CP07:22:L:MVAL")
#! Record("RCMP:CP07:22:L:MODE_STRING",1760,2434,0,1,"RCMP:CP07:22:L:MODE_STRING")
#! Record("RCMP:CP07:22:L:SVAL",1960,2499,0,1,"RCMP:CP07:22:L:SVAL")
#! Record("RCMP:CP07:22:L:PIDTAG",1760,2582,0,1,"RCMP:CP07:22:L:PIDTAG")
#! Record("RCMP:CP07:22:L:SMOD",2864,2499,0,1,"RCMP:CP07:22:L:SMOD")
#! Record("RCMP:CP07:22:L:CMD_OUT",2860,2286,0,1,"RCMP:CP07:22:L:CMD_OUT")
#! Record("RCMP:CP07:22:L:SWITCH_DISABLE",3060,2720,0,1,"RCMP:CP07:22:L:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "RCMP:CP07:22:U:MMOD") {
  field(DESC, "Man. Mode status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.mmod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bi, "RCMP:CP07:22:U:IMOD") {
  field(DESC, "Interlock mode")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.imod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "RCMP:CP07:22:U:TEXT1") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(stringin, "RCMP:CP07:22:U:TEXT2") {
  field(DESC, "Notes")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  info(autosaveFields, "VAL")
}

record(bi, "RCMP:CP07:22:U:INTERLOCK") {
  field(DESC, "interlock status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.Interlock_Condition")
  field(ZNAM, "ok")
  field(ONAM, "interlocked")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:22:U:IVAL") {
  field(DESC, "interlock state")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.ival")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:22:U:OUTPUT") {
  field(DESC, "actuatorDO output command")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.Output")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(bo, "RCMP:CP07:22:U:MANUAL") {
  field(DESC, "Manual Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CMP722_UL.Manual B 0")
  field(ZNAM, "not manual")
  field(ONAM, "Manual")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bo, "RCMP:CP07:22:U:SEQUENCER") {
  field(DESC, "SEQ Mode request ")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CMP722_UL.Sequencer B 0")
  field(ZNAM, "not sequencer")
  field(ONAM, "Sequencer")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(ai, "RCMP:CP07:22:U:MODE") {
  field(DESC, "actuator mode (man,ovr,seq)")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.MODE")
}

record(bi, "RCMP:CP07:22:U:ALM") {
  field(DESC, "Limit SW alarm")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.ER")
  field(ZNAM, "ok")
  field(ONAM, "alarm")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:22:U:IL_LATCH") {
  field(DESC, "interlock latched indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.Interlock_Condition_L")
  field(ZNAM, "ok")
  field(ONAM, "latched")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bo, "RCMP:CP07:22:U:IL_RESET") {
  field(DESC, "Interlock Latch Reset")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) CMP722_UL.Interlock_Condition_Reset B 0")
  field(ZNAM, "not reset")
  field(ONAM, "RESET")
  field(ASG, "CRYO")
  field(HIGH, "1")
  field(IVOA, "Don't drive outputs")
}

record(bi, "RCMP:CP07:22:U:ZSH") {
  field(DESC, "High limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.ZSH")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:22:U:ZSL") {
  field(DESC, "low limit sw value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.ZSL")
  field(ZNAM, "not active")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:22:U:MVAL") {
  field(DESC, "manual mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.mval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "RCMP:CP07:22:U:MODE_STRING") {
  field(DESC, "Actuator (DO) Mode String")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.Mode_String")
}

record(bi, "RCMP:CP07:22:U:SVAL") {
  field(DESC, "sequencer mode output value")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.sval")
  field(ZNAM, "close")
  field(ONAM, "open")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(stringin, "RCMP:CP07:22:U:PIDTAG") {
  field(DESC, "RCMP722 Unload PIDTAG")
  field(PINI, "YES")
  field(VAL, "CCMP722UL")
}

record(bi, "RCMP:CP07:22:U:SMOD") {
  field(DESC, "Sequencer mode indicator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.smod")
  field(ZNAM, "inactive")
  field(ONAM, "active")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "RCMP:CP07:22:U:CMD_OUT") {
  field(DESC, "rdbk of output signal to the actuator")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_ULO")
  field(ZNAM, "close")
  field(ONAM, "open")
}

record(mbbiDirect, "RCMP:CP07:22:U:SWITCH_DISABLE") {
  field(DESC, "Indicates if switch(es) are  used")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMP722_UL.Disable B 0")
  field(NOBT, "16")
}

#! Further lines contain data used by VisualDCT
#! View(1599,2252,1.0)
#! Record("RCMP:CP07:22:U:MMOD",2500,2499,0,1,"RCMP:CP07:22:U:MMOD")
#! Record("RCMP:CP07:22:U:IMOD",2680,2499,0,1,"RCMP:CP07:22:U:IMOD")
#! Record("RCMP:CP07:22:U:TEXT1",1760,2682,0,1,"RCMP:CP07:22:U:TEXT1")
#! Record("RCMP:CP07:22:U:TEXT2",1760,2782,0,1,"RCMP:CP07:22:U:TEXT2")
#! Record("RCMP:CP07:22:U:INTERLOCK",2500,2719,0,1,"RCMP:CP07:22:U:INTERLOCK")
#! Record("RCMP:CP07:22:U:IVAL",2140,2499,0,1,"RCMP:CP07:22:U:IVAL")
#! Record("RCMP:CP07:22:U:OUTPUT",2680,2279,0,1,"RCMP:CP07:22:U:OUTPUT")
#! Record("RCMP:CP07:22:U:MANUAL",1960,2265,0,1,"RCMP:CP07:22:U:MANUAL")
#! Record("RCMP:CP07:22:U:SEQUENCER",2140,2265,0,1,"RCMP:CP07:22:U:SEQUENCER")
#! Record("RCMP:CP07:22:U:MODE",1760,2274,0,1,"RCMP:CP07:22:U:MODE")
#! Record("RCMP:CP07:22:U:ALM",1960,2719,0,1,"RCMP:CP07:22:U:ALM")
#! Record("RCMP:CP07:22:U:IL_LATCH",2320,2719,0,1,"RCMP:CP07:22:U:IL_LATCH")
#! Record("RCMP:CP07:22:U:IL_RESET",2140,2705,0,1,"RCMP:CP07:22:U:IL_RESET")
#! Record("RCMP:CP07:22:U:ZSH",2700,2719,0,1,"RCMP:CP07:22:U:ZSH")
#! Record("RCMP:CP07:22:U:ZSL",2880,2719,0,1,"RCMP:CP07:22:U:ZSL")
#! Record("RCMP:CP07:22:U:MVAL",2320,2499,0,1,"RCMP:CP07:22:U:MVAL")
#! Record("RCMP:CP07:22:U:MODE_STRING",1760,2434,0,1,"RCMP:CP07:22:U:MODE_STRING")
#! Record("RCMP:CP07:22:U:SVAL",1960,2499,0,1,"RCMP:CP07:22:U:SVAL")
#! Record("RCMP:CP07:22:U:PIDTAG",1760,2582,0,1,"RCMP:CP07:22:U:PIDTAG")
#! Record("RCMP:CP07:22:U:SMOD",2864,2499,0,1,"RCMP:CP07:22:U:SMOD")
#! Record("RCMP:CP07:22:U:CMD_OUT",2860,2286,0,1,"RCMP:CP07:22:U:CMD_OUT")
#! Record("RCMP:CP07:22:U:SWITCH_DISABLE",3060,2720,0,1,"RCMP:CP07:22:U:SWITCH_DISABLE")
#! TextBox(TB0,1880,2020,2340,2240,0,"Dialog",12,1,16777215,"Generic Actuator records (DO_Record)\n- NOTE this database is the interface to the DO_Record in PLC codes\n- NOTE each of the components using this database\n             should also use the on_off_confirm database\nMode\nOverride\nInterlock status\nMode status\nText records\n\nNOTE: there are autosave info fields in this file for the \nTEXT1 and TEXT2 strings that DO NOT show in VDCT",null)
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "CEP:CP07:3100:TOGGLE") {
  field(DESC, "Purf1 Test Toggle")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) Pur_Test_1")
  field(ZNAM, "Default")
  field(ONAM, "Test")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(ASG, "CRYO")
  field(HIGH, "0")
  field(IVOA, "Don't drive outputs")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CEP:CP07:3100:TOGGLE",2060,2137,0,1,"CEP:CP07:3100:TOGGLE")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bo, "CEP:CP07:3200:TOGGLE") {
  field(DESC, "Purf2 Test Toggle")
  field(PINI, "NO")
  field(DTYP, "EtherIP")
  field(OMSL, "supervisory")
  field(OUT, "@$(PLC_NAME) Pur_Test_2")
  field(ZNAM, "Default")
  field(ONAM, "Test")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(ASG, "CRYO")
  field(HIGH, "0")
  field(IVOA, "Don't drive outputs")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CEP:CP07:3200:TOGGLE",2060,2137,0,1,"CEP:CP07:3200:TOGGLE")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "CZSH:CP08:4110:LIMIT_SW") {
  field(DESC, "Inlet vlv open switch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CLSO84110")
  field(ZNAM, "not open")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(stringin, "CZSH:CP08:4110:PIDTAG") {
  field(DESC, "Lmt Swch P&IDname")
  field(PINI, "YES")
  field(VAL, "CZSH84110")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CZSH:CP08:4110:LIMIT_SW",2054,2119,0,1,"CZSH:CP08:4110:LIMIT_SW")
#! Record("CZSH:CP08:4110:PIDTAG",2054,2322,0,1,"CZSH:CP08:4110:PIDTAG")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(bi, "CZSH:CP08:4210:LIMIT_SW") {
  field(DESC, "Inlet vlv open switch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CLSO84210")
  field(ZNAM, "not open")
  field(ONAM, "open")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

record(stringin, "CZSH:CP08:4210:PIDTAG") {
  field(DESC, "Lmt Swch P&IDname")
  field(PINI, "YES")
  field(VAL, "CZSH84210")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CZSH:CP08:4210:LIMIT_SW",2054,2119,0,1,"CZSH:CP08:4210:LIMIT_SW")
#! Record("CZSH:CP08:4210:PIDTAG",2054,2322,0,1,"CZSH:CP08:4210:PIDTAG")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CCMP:CP07:2100:PIDTAG") {
  field(DESC, "ESTOP P&IDname")
  field(PINI, "YES")
  field(VAL, "CCMP72100")
}


record(bi, "CCMP:CP07:2100:ESTOP") {
  field(DESC, "RCmp 1 E-Stop")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CCMP721_ES")
  field(ZNAM, "stopped")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CCMP:CP07:2100:PIDTAG",2054,2322,0,1,"CCMP:CP07:2100:PIDTAG")
#! Record("CCMP:CP07:2100:ESTOP",2054,2119,0,1,"CCMP:CP07:2100:ESTOP")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CCMP:CP07:2200:PIDTAG") {
  field(DESC, "ESTOP P&IDname")
  field(PINI, "YES")
  field(VAL, "CCMP72200")
}


record(bi, "CCMP:CP07:2200:ESTOP") {
  field(DESC, "RCmp 2 E-Stop")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CCMP722_ES")
  field(ZNAM, "stopped")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CCMP:CP07:2200:PIDTAG",2054,2322,0,1,"CCMP:CP07:2200:PIDTAG")
#! Record("CCMP:CP07:2200:ESTOP",2054,2119,0,1,"CCMP:CP07:2200:ESTOP")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CCMP:CP07:2100:PIDTAG") {
  field(DESC, "JT_ON P&IDname")
  field(PINI, "YES")
  field(VAL, "CCMP721")
}


record(bi, "CCMP:CP07:2100:JT_ON") {
  field(DESC, "RCmp1 Motor start status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CCMP721_JT_ON")
  field(ZNAM, "motor not on")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CCMP:CP07:2100:PIDTAG",2054,2322,0,1,"CCMP:CP07:2100:PIDTAG")
#! Record("CCMP:CP07:2100:JT_ON",2054,2119,0,1,"CCMP:CP07:2100:JT_ON")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CCMP:CP07:2200:PIDTAG") {
  field(DESC, "JT_ON P&IDname")
  field(PINI, "YES")
  field(VAL, "CCMP722")
}


record(bi, "CCMP:CP07:2200:JT_ON") {
  field(DESC, "RCmp2 Motor start Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CCMP722_JT_ON")
  field(ZNAM, "motor not on")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CCMP:CP07:2200:PIDTAG",2054,2322,0,1,"CCMP:CP07:2200:PIDTAG")
#! Record("CCMP:CP07:2200:JT_ON",2054,2119,0,1,"CCMP:CP07:2200:JT_ON")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "RCMP:CP07:2100:PIDTAG") {
  field(DESC, "SUMP_PMSV P&IDname")
  field(PINI, "YES")
  field(VAL, "CCMP721")
}


record(bi, "RCMP:CP07:2100:SUMP_PMSV") {
  field(DESC, "RCmp1 sump temp prmsv")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) Run_CMP721_PMSV")
  field(ZNAM, "temp too low")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("RCMP:CP07:2100:PIDTAG",2054,2322,0,1,"RCMP:CP07:2100:PIDTAG")
#! Record("RCMP:CP07:2100:SUMP_PMSV",2054,2119,0,1,"RCMP:CP07:2100:SUMP_PMSV")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "RCMP:CP07:2200:PIDTAG") {
  field(DESC, "SUMP_PMSV P&IDname")
  field(PINI, "YES")
  field(VAL, "CCMP722")
}


record(bi, "RCMP:CP07:2200:SUMP_PMSV") {
  field(DESC, "RCmp2 sump temp prmsv")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) Run_CMP722_PMSV")
  field(ZNAM, "temp too low")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("RCMP:CP07:2200:PIDTAG",2054,2322,0,1,"RCMP:CP07:2200:PIDTAG")
#! Record("RCMP:CP07:2200:SUMP_PMSV",2054,2119,0,1,"RCMP:CP07:2200:SUMP_PMSV")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CMTR:CP07:2100:PIDTAG") {
  field(DESC, "OVERLD P&IDname")
  field(PINI, "YES")
  field(VAL, "CMTR72100")
}


record(bi, "CMTR:CP07:2100:OVERLD") {
  field(DESC, "RCmp 1 Overld")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMTR721_OL")
  field(ZNAM, "overload")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CMTR:CP07:2100:PIDTAG",2054,2322,0,1,"CMTR:CP07:2100:PIDTAG")
#! Record("CMTR:CP07:2100:OVERLD",2054,2119,0,1,"CMTR:CP07:2100:OVERLD")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CMTR:CP07:2200:PIDTAG") {
  field(DESC, "OVERLD P&IDname")
  field(PINI, "YES")
  field(VAL, "CMTR72200")
}


record(bi, "CMTR:CP07:2200:OVERLD") {
  field(DESC, "RCmp 2 Overld")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMTR722_OL")
  field(ZNAM, "overload")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CMTR:CP07:2200:PIDTAG",2054,2322,0,1,"CMTR:CP07:2200:PIDTAG")
#! Record("CMTR:CP07:2200:OVERLD",2054,2119,0,1,"CMTR:CP07:2200:OVERLD")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CLSL:CP07:2100:PIDTAG") {
  field(DESC, "LIMIT_SW P&IDname")
  field(PINI, "YES")
  field(VAL, "CLSL72100")
}


record(bi, "CLSL:CP07:2100:LIMIT_SW") {
  field(DESC, "RCmp1 Oil Lvl")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CLSL72100")
  field(ZNAM, "fault")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CLSL:CP07:2100:PIDTAG",2054,2322,0,1,"CLSL:CP07:2100:PIDTAG")
#! Record("CLSL:CP07:2100:LIMIT_SW",2054,2119,0,1,"CLSL:CP07:2100:LIMIT_SW")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CLSL:CP07:2200:PIDTAG") {
  field(DESC, "LIMIT_SW P&IDname")
  field(PINI, "YES")
  field(VAL, "CLSL72200")
}


record(bi, "CLSL:CP07:2200:LIMIT_SW") {
  field(DESC, "RCmp2 Oil Lvl")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CLSL72200")
  field(ZNAM, "fault")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CLSL:CP07:2200:PIDTAG",2054,2322,0,1,"CLSL:CP07:2200:PIDTAG")
#! Record("CLSL:CP07:2200:LIMIT_SW",2054,2119,0,1,"CLSL:CP07:2200:LIMIT_SW")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CPSL:CP07:2112:PIDTAG") {
  field(DESC, "LIMIT_SW P&IDname")
  field(PINI, "YES")
  field(VAL, "CPSL72112")
}


record(bi, "CPSL:CP07:2112:LIMIT_SW") {
  field(DESC, "RCmp1 Suctn Lo Pr")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CPSL72112")
  field(ZNAM, "fault")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CPSL:CP07:2112:PIDTAG",2054,2322,0,1,"CPSL:CP07:2112:PIDTAG")
#! Record("CPSL:CP07:2112:LIMIT_SW",2054,2119,0,1,"CPSL:CP07:2112:LIMIT_SW")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CPSL:CP07:2212:PIDTAG") {
  field(DESC, "LIMIT_SW P&IDname")
  field(PINI, "YES")
  field(VAL, "CPSL72212")
}


record(bi, "CPSL:CP07:2212:LIMIT_SW") {
  field(DESC, "RCmp2 Suctn Lo Pr")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CPSL72212")
  field(ZNAM, "fault")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CPSL:CP07:2212:PIDTAG",2054,2322,0,1,"CPSL:CP07:2212:PIDTAG")
#! Record("CPSL:CP07:2212:LIMIT_SW",2054,2119,0,1,"CPSL:CP07:2212:LIMIT_SW")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CPSH:CP07:2120:PIDTAG") {
  field(DESC, "LIMIT_SW P&IDname")
  field(PINI, "YES")
  field(VAL, "CPSH72120")
}


record(bi, "CPSH:CP07:2120:LIMIT_SW") {
  field(DESC, "RCmp1 Dschg Hi Pr")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CPSH72120")
  field(ZNAM, "fault")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CPSH:CP07:2120:PIDTAG",2054,2322,0,1,"CPSH:CP07:2120:PIDTAG")
#! Record("CPSH:CP07:2120:LIMIT_SW",2054,2119,0,1,"CPSH:CP07:2120:LIMIT_SW")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CPSH:CP07:2220:PIDTAG") {
  field(DESC, "LIMIT_SW P&IDname")
  field(PINI, "YES")
  field(VAL, "CPSH72220")
}


record(bi, "CPSH:CP07:2220:LIMIT_SW") {
  field(DESC, "RCmp2 Dschg Hi Pr")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CPSH72220")
  field(ZNAM, "fault")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CPSH:CP07:2220:PIDTAG",2054,2322,0,1,"CPSH:CP07:2220:PIDTAG")
#! Record("CPSH:CP07:2220:LIMIT_SW",2054,2119,0,1,"CPSH:CP07:2220:LIMIT_SW")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CTSH:CP07:2100:PIDTAG") {
  field(DESC, "LIMIT_SW P&IDname")
  field(PINI, "YES")
  field(VAL, "CTSH72100")
}


record(bi, "CTSH:CP07:2100:LIMIT_SW") {
  field(DESC, "RCmp1 Motor Hi Tmp")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CTSH72100")
  field(ZNAM, "fault")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CTSH:CP07:2100:PIDTAG",2054,2322,0,1,"CTSH:CP07:2100:PIDTAG")
#! Record("CTSH:CP07:2100:LIMIT_SW",2054,2119,0,1,"CTSH:CP07:2100:LIMIT_SW")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CTSH:CP07:2200:PIDTAG") {
  field(DESC, "LIMIT_SW P&IDname")
  field(PINI, "YES")
  field(VAL, "CTSH72200")
}


record(bi, "CTSH:CP07:2200:LIMIT_SW") {
  field(DESC, "RCmp2 Motor Hi Tmp")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CTSH72200")
  field(ZNAM, "fault")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CTSH:CP07:2200:PIDTAG",2054,2322,0,1,"CTSH:CP07:2200:PIDTAG")
#! Record("CTSH:CP07:2200:LIMIT_SW",2054,2119,0,1,"CTSH:CP07:2200:LIMIT_SW")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CPSP:CP07:2100:PIDTAG") {
  field(DESC, "STATUS P&IDname")
  field(PINI, "YES")
  field(VAL, "CPSP72100")
}


record(bi, "CPSP:CP07:2100:STATUS") {
  field(DESC, "RCmp1 24VRemPower")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CPSP721_R")
  field(ZNAM, "faulted")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CPSP:CP07:2100:PIDTAG",2054,2322,0,1,"CPSP:CP07:2100:PIDTAG")
#! Record("CPSP:CP07:2100:STATUS",2054,2119,0,1,"CPSP:CP07:2100:STATUS")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CPSP:CP07:2200:PIDTAG") {
  field(DESC, "STATUS P&IDname")
  field(PINI, "YES")
  field(VAL, "CPSP72200")
}


record(bi, "CPSP:CP07:2200:STATUS") {
  field(DESC, "RCmp2 24VRemPower")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CPSP722_R")
  field(ZNAM, "faulted")
  field(ONAM, "ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CPSP:CP07:2200:PIDTAG",2054,2322,0,1,"CPSP:CP07:2200:PIDTAG")
#! Record("CPSP:CP07:2200:STATUS",2054,2119,0,1,"CPSP:CP07:2200:STATUS")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CMTR:CP07:2100:PIDTAG") {
  field(DESC, "STATUS P&IDname")
  field(PINI, "YES")
  field(VAL, "CMTR72100")
}


record(bi, "CMTR:CP07:2100:STATUS") {
  field(DESC, "RCmp 1 run status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMTR721_R")
  field(ZNAM, "off")
  field(ONAM, "on")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CMTR:CP07:2100:PIDTAG",2054,2322,0,1,"CMTR:CP07:2100:PIDTAG")
#! Record("CMTR:CP07:2100:STATUS",2054,2119,0,1,"CMTR:CP07:2100:STATUS")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CMTR:CP07:2200:PIDTAG") {
  field(DESC, "STATUS P&IDname")
  field(PINI, "YES")
  field(VAL, "CMTR72200")
}


record(bi, "CMTR:CP07:2200:STATUS") {
  field(DESC, "RCmp 2 run status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CMTR722_R")
  field(ZNAM, "off")
  field(ONAM, "on")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CMTR:CP07:2200:PIDTAG",2054,2322,0,1,"CMTR:CP07:2200:PIDTAG")
#! Record("CMTR:CP07:2200:STATUS",2054,2119,0,1,"CMTR:CP07:2200:STATUS")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CTP:CP07:2120:PIDTAG") {
  field(DESC, "TRIP P&IDname")
  field(PINI, "YES")
  field(VAL, "CTP72120")
}


record(bi, "CTP:CP07:2120:TRIP") {
  field(DESC, "RCmp1 Dschg HiTmp Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CTP72120_TRP")
  field(ZNAM, "ok")
  field(ONAM, "temp too high")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CTP:CP07:2120:PIDTAG",2054,2322,0,1,"CTP:CP07:2120:PIDTAG")
#! Record("CTP:CP07:2120:TRIP",2054,2119,0,1,"CTP:CP07:2120:TRIP")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CTP:CP07:2220:PIDTAG") {
  field(DESC, "TRIP P&IDname")
  field(PINI, "YES")
  field(VAL, "CTP72220")
}


record(bi, "CTP:CP07:2220:TRIP") {
  field(DESC, "RCmp2 Dschg HiTmp Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CTP72220_TRP")
  field(ZNAM, "ok")
  field(ONAM, "temp too high")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CTP:CP07:2220:PIDTAG",2054,2322,0,1,"CTP:CP07:2220:PIDTAG")
#! Record("CTP:CP07:2220:TRIP",2054,2119,0,1,"CTP:CP07:2220:TRIP")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CPT:CP07:2120:PIDTAG") {
  field(DESC, "TRIP P&IDname")
  field(PINI, "YES")
  field(VAL, "CPT72120")
}


record(bi, "CPT:CP07:2120:TRIP") {
  field(DESC, "RCmp1 Dschg HiPr Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CPT72120_TRP")
  field(ZNAM, "ok")
  field(ONAM, "pr too high")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CPT:CP07:2120:PIDTAG",2054,2322,0,1,"CPT:CP07:2120:PIDTAG")
#! Record("CPT:CP07:2120:TRIP",2054,2119,0,1,"CPT:CP07:2120:TRIP")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CPT:CP07:2220:PIDTAG") {
  field(DESC, "TRIP P&IDname")
  field(PINI, "YES")
  field(VAL, "CPT72220")
}


record(bi, "CPT:CP07:2220:TRIP") {
  field(DESC, "RCmp2 Dschg HiPr Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CPT72220_TRP")
  field(ZNAM, "ok")
  field(ONAM, "pr too high")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CPT:CP07:2220:PIDTAG",2054,2322,0,1,"CPT:CP07:2220:PIDTAG")
#! Record("CPT:CP07:2220:TRIP",2054,2119,0,1,"CPT:CP07:2220:TRIP")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CPT:CP07:2112:PIDTAG") {
  field(DESC, "TRIP P&IDname")
  field(PINI, "YES")
  field(VAL, "CPT72120")
}


record(bi, "CPT:CP07:2112:TRIP") {
  field(DESC, "RCmp1 Suctn LowPr Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CPT72112_TRP")
  field(ZNAM, "ok")
  field(ONAM, "pr too low")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CPT:CP07:2112:PIDTAG",2054,2322,0,1,"CPT:CP07:2112:PIDTAG")
#! Record("CPT:CP07:2112:TRIP",2054,2119,0,1,"CPT:CP07:2112:TRIP")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CPT:CP07:2212:PIDTAG") {
  field(DESC, "TRIP P&IDname")
  field(PINI, "YES")
  field(VAL, "CPT72220")
}


record(bi, "CPT:CP07:2212:TRIP") {
  field(DESC, "RCmp2 Suctn LowPr Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CPT72212_TRP")
  field(ZNAM, "ok")
  field(ONAM, "pr too low")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CPT:CP07:2212:PIDTAG",2054,2322,0,1,"CPT:CP07:2212:PIDTAG")
#! Record("CPT:CP07:2212:TRIP",2054,2119,0,1,"CPT:CP07:2212:TRIP")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CVP:CP08:4100:PIDTAG") {
  field(DESC, "STATUS P&IDname")
  field(PINI, "YES")
  field(VAL, "CVP84100")
}


record(bi, "CVP:CP08:4100:STATUS") {
  field(DESC, "Vacuum Pump 1 status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CVP84100R")
  field(ZNAM, "off")
  field(ONAM, "on")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CVP:CP08:4100:PIDTAG",2054,2322,0,1,"CVP:CP08:4100:PIDTAG")
#! Record("CVP:CP08:4100:STATUS",2054,2119,0,1,"CVP:CP08:4100:STATUS")
#! Generated by VisualDCT v2.6.1280
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(stringin, "CVP:CP08:4200:PIDTAG") {
  field(DESC, "STATUS P&IDname")
  field(PINI, "YES")
  field(VAL, "CVP84200")
}


record(bi, "CVP:CP08:4200:STATUS") {
  field(DESC, "Vacuum Pump 2 status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) CVP84200R")
  field(ZNAM, "off")
  field(ONAM, "on")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
}

#! Further lines contain data used by VisualDCT
#! View(2000,2115,1.0)
#! Record("CVP:CP08:4200:PIDTAG",2054,2322,0,1,"CVP:CP08:4200:PIDTAG")
#! Record("CVP:CP08:4200:STATUS",2054,2119,0,1,"CVP:CP08:4200:STATUS")