#! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CTIC:CP$(CP)2:2418:A:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2418:A:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2418:A:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A.CVAL") field(PREC, "2") field(EGU, "K") field(ADEL, ".01") } record(ao, "CTIC:CP$(CP)2:2418:A:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:A:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:A:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2418:A:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:A:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:A:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:A:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:A:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CTIC:CP$(CP)2:2418:A:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:A:SP_RQST") { field(DESC, "C$(CP)TIC22418A PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A_OVH.SP_Rqst") field(PREC, "2") field(EGU, "K") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:A:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CTIC:CP$(CP)2:2418:A:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)TIC22418A") } record(ao, "CTIC:CP$(CP)2:2418:A:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2418:A:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CTIC:CP$(CP)2:2418:A:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CTIC:CP$(CP)2:2418:A:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CTIC:CP$(CP)2:2418:A:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CTIC:CP$(CP)2:2418:A:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2418:A:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2418:A:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CTIC:CP$(CP)2:2418:A:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CTIC:CP$(CP)2:2418:A:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CTIC:CP$(CP)2:2418:A:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CTIC:CP$(CP)2:2418:A:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CTIC:CP$(CP)2:2418:A:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A_OVH.Mode_String") } record(bi, "CTIC:CP$(CP)2:2418:A:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CTIC:CP$(CP)2:2418:A:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CTIC:CP$(CP)2:2418:A:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "EHTR22418A") } record(ai, "CTIC:CP$(CP)2:2418:A:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418A.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CTIC:CP$(CP)2:2418:A:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418A.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CTIC:CP$(CP)2:2418:A:ORBV",2100,2312,0,1,"CTIC:CP$(CP)2:2418:A:ORBV") #! Record("CTIC:CP$(CP)2:2418:A:OVAL",2280,2312,0,1,"CTIC:CP$(CP)2:2418:A:OVAL") #! Record("CTIC:CP$(CP)2:2418:A:CVAL",2460,2312,0,1,"CTIC:CP$(CP)2:2418:A:CVAL") #! Record("CTIC:CP$(CP)2:2418:A:MAX",2122,1932,0,1,"CTIC:CP$(CP)2:2418:A:MAX") #! Record("CTIC:CP$(CP)2:2418:A:DMIN",2300,1932,0,1,"CTIC:CP$(CP)2:2418:A:DMIN") #! Record("CTIC:CP$(CP)2:2418:A:DMAX",2479,1932,0,1,"CTIC:CP$(CP)2:2418:A:DMAX") #! Record("CTIC:CP$(CP)2:2418:A:MODE_RQST",1760,2112,0,1,"CTIC:CP$(CP)2:2418:A:MODE_RQST") #! Record("CTIC:CP$(CP)2:2418:A:MDT",2120,2112,0,1,"CTIC:CP$(CP)2:2418:A:MDT") #! Record("CTIC:CP$(CP)2:2418:A:KP",2300,2106,0,1,"CTIC:CP$(CP)2:2418:A:KP") #! Record("CTIC:CP$(CP)2:2418:A:KI",2480,2106,0,1,"CTIC:CP$(CP)2:2418:A:KI") #! Record("CTIC:CP$(CP)2:2418:A:KD",2660,2106,0,1,"CTIC:CP$(CP)2:2418:A:KD") #! Record("CTIC:CP$(CP)2:2418:A:S",2840,2120,0,1,"CTIC:CP$(CP)2:2418:A:S") #! Record("CTIC:CP$(CP)2:2418:A:SP_RQST",1760,1932,0,1,"CTIC:CP$(CP)2:2418:A:SP_RQST") #! Record("CTIC:CP$(CP)2:2418:A:MIN",1945,1932,0,1,"CTIC:CP$(CP)2:2418:A:MIN") #! Record("CTIC:CP$(CP)2:2418:A:PIDTAG",1740,2462,0,1,"CTIC:CP$(CP)2:2418:A:PIDTAG") #! Record("CTIC:CP$(CP)2:2418:A:PEVAL",2660,1932,0,1,"CTIC:CP$(CP)2:2418:A:PEVAL") #! Record("CTIC:CP$(CP)2:2418:A:FSB",2840,1932,0,1,"CTIC:CP$(CP)2:2418:A:FSB") #! Record("CTIC:CP$(CP)2:2418:A:NOMATCH",2640,2506,0,1,"CTIC:CP$(CP)2:2418:A:NOMATCH") #! Record("CTIC:CP$(CP)2:2418:A:CHFAULT",2820,2506,0,1,"CTIC:CP$(CP)2:2418:A:CHFAULT") #! Record("CTIC:CP$(CP)2:2418:A:MANPOS_RQST",1940,2112,0,1,"CTIC:CP$(CP)2:2418:A:MANPOS_RQST") #! Record("CTIC:CP$(CP)2:2418:A:MODE_STATUS",1740,2639,0,1,"CTIC:CP$(CP)2:2418:A:MODE_STATUS") #! Record("CTIC:CP$(CP)2:2418:A:INTERLOCKED",2460,2686,0,0,"CTIC:CP$(CP)2:2418:A:INTERLOCKED") #! Record("CTIC:CP$(CP)2:2418:A:INTERLOCK",2460,2506,0,0,"CTIC:CP$(CP)2:2418:A:INTERLOCK") #! Record("CTIC:CP$(CP)2:2418:A:IVAL",2641,2312,0,1,"CTIC:CP$(CP)2:2418:A:IVAL") #! Record("CTIC:CP$(CP)2:2418:A:SVAL",2820,2312,0,1,"CTIC:CP$(CP)2:2418:A:SVAL") #! Record("CTIC:CP$(CP)2:2418:A:MMOD",2102,2506,0,1,"CTIC:CP$(CP)2:2418:A:MMOD") #! Record("CTIC:CP$(CP)2:2418:A:SMOD",2282,2506,0,1,"CTIC:CP$(CP)2:2418:A:SMOD") #! Record("CTIC:CP$(CP)2:2418:A:MODE_STRING",1740,2314,0,1,"CTIC:CP$(CP)2:2418:A:MODE_STRING") #! Record("CTIC:CP$(CP)2:2418:A:PMOD",1922,2506,0,1,"CTIC:CP$(CP)2:2418:A:PMOD") #! Record("CTIC:CP$(CP)2:2418:A:IMOD",3020,2506,0,1,"CTIC:CP$(CP)2:2418:A:IMOD") #! Record("CTIC:CP$(CP)2:2418:A:ACTUATOR",1920,2322,0,1,"CTIC:CP$(CP)2:2418:A:ACTUATOR") #! Record("CTIC:CP$(CP)2:2418:A:PVAL",3000,2312,0,1,"CTIC:CP$(CP)2:2418:A:PVAL") #! Record("CTIC:CP$(CP)2:2418:A:CMD",3021,2112,0,1,"CTIC:CP$(CP)2:2418:A:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCTIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2418:A location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CTIC:CP$(CP)2:2418:B:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2418:B:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2418:B:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B.CVAL") field(PREC, "2") field(EGU, "K") field(ADEL, ".01") } record(ao, "CTIC:CP$(CP)2:2418:B:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:B:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:B:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2418:B:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:B:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:B:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:B:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:B:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CTIC:CP$(CP)2:2418:B:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:B:SP_RQST") { field(DESC, "C$(CP)TIC22418B PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B_OVH.SP_Rqst") field(PREC, "2") field(EGU, "K") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2418:B:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CTIC:CP$(CP)2:2418:B:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)TIC22418B") } record(ao, "CTIC:CP$(CP)2:2418:B:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2418:B:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CTIC:CP$(CP)2:2418:B:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CTIC:CP$(CP)2:2418:B:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CTIC:CP$(CP)2:2418:B:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CTIC:CP$(CP)2:2418:B:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2418:B:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2418:B:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CTIC:CP$(CP)2:2418:B:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CTIC:CP$(CP)2:2418:B:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CTIC:CP$(CP)2:2418:B:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CTIC:CP$(CP)2:2418:B:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CTIC:CP$(CP)2:2418:B:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B_OVH.Mode_String") } record(bi, "CTIC:CP$(CP)2:2418:B:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CTIC:CP$(CP)2:2418:B:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CTIC:CP$(CP)2:2418:B:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "EHTR22418B") } record(ai, "CTIC:CP$(CP)2:2418:B:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22418B.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CTIC:CP$(CP)2:2418:B:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22418B.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CTIC:CP$(CP)2:2418:B:ORBV",2100,2312,0,1,"CTIC:CP$(CP)2:2418:B:ORBV") #! Record("CTIC:CP$(CP)2:2418:B:OVAL",2280,2312,0,1,"CTIC:CP$(CP)2:2418:B:OVAL") #! Record("CTIC:CP$(CP)2:2418:B:CVAL",2460,2312,0,1,"CTIC:CP$(CP)2:2418:B:CVAL") #! Record("CTIC:CP$(CP)2:2418:B:MAX",2122,1932,0,1,"CTIC:CP$(CP)2:2418:B:MAX") #! Record("CTIC:CP$(CP)2:2418:B:DMIN",2300,1932,0,1,"CTIC:CP$(CP)2:2418:B:DMIN") #! Record("CTIC:CP$(CP)2:2418:B:DMAX",2479,1932,0,1,"CTIC:CP$(CP)2:2418:B:DMAX") #! Record("CTIC:CP$(CP)2:2418:B:MODE_RQST",1760,2112,0,1,"CTIC:CP$(CP)2:2418:B:MODE_RQST") #! Record("CTIC:CP$(CP)2:2418:B:MDT",2120,2112,0,1,"CTIC:CP$(CP)2:2418:B:MDT") #! Record("CTIC:CP$(CP)2:2418:B:KP",2300,2106,0,1,"CTIC:CP$(CP)2:2418:B:KP") #! Record("CTIC:CP$(CP)2:2418:B:KI",2480,2106,0,1,"CTIC:CP$(CP)2:2418:B:KI") #! Record("CTIC:CP$(CP)2:2418:B:KD",2660,2106,0,1,"CTIC:CP$(CP)2:2418:B:KD") #! Record("CTIC:CP$(CP)2:2418:B:S",2840,2120,0,1,"CTIC:CP$(CP)2:2418:B:S") #! Record("CTIC:CP$(CP)2:2418:B:SP_RQST",1760,1932,0,1,"CTIC:CP$(CP)2:2418:B:SP_RQST") #! Record("CTIC:CP$(CP)2:2418:B:MIN",1945,1932,0,1,"CTIC:CP$(CP)2:2418:B:MIN") #! Record("CTIC:CP$(CP)2:2418:B:PIDTAG",1740,2462,0,1,"CTIC:CP$(CP)2:2418:B:PIDTAG") #! Record("CTIC:CP$(CP)2:2418:B:PEVAL",2660,1932,0,1,"CTIC:CP$(CP)2:2418:B:PEVAL") #! Record("CTIC:CP$(CP)2:2418:B:FSB",2840,1932,0,1,"CTIC:CP$(CP)2:2418:B:FSB") #! Record("CTIC:CP$(CP)2:2418:B:NOMATCH",2640,2506,0,1,"CTIC:CP$(CP)2:2418:B:NOMATCH") #! Record("CTIC:CP$(CP)2:2418:B:CHFAULT",2820,2506,0,1,"CTIC:CP$(CP)2:2418:B:CHFAULT") #! Record("CTIC:CP$(CP)2:2418:B:MANPOS_RQST",1940,2112,0,1,"CTIC:CP$(CP)2:2418:B:MANPOS_RQST") #! Record("CTIC:CP$(CP)2:2418:B:MODE_STATUS",1740,2639,0,1,"CTIC:CP$(CP)2:2418:B:MODE_STATUS") #! Record("CTIC:CP$(CP)2:2418:B:INTERLOCKED",2460,2686,0,0,"CTIC:CP$(CP)2:2418:B:INTERLOCKED") #! Record("CTIC:CP$(CP)2:2418:B:INTERLOCK",2460,2506,0,0,"CTIC:CP$(CP)2:2418:B:INTERLOCK") #! Record("CTIC:CP$(CP)2:2418:B:IVAL",2641,2312,0,1,"CTIC:CP$(CP)2:2418:B:IVAL") #! Record("CTIC:CP$(CP)2:2418:B:SVAL",2820,2312,0,1,"CTIC:CP$(CP)2:2418:B:SVAL") #! Record("CTIC:CP$(CP)2:2418:B:MMOD",2102,2506,0,1,"CTIC:CP$(CP)2:2418:B:MMOD") #! Record("CTIC:CP$(CP)2:2418:B:SMOD",2282,2506,0,1,"CTIC:CP$(CP)2:2418:B:SMOD") #! Record("CTIC:CP$(CP)2:2418:B:MODE_STRING",1740,2314,0,1,"CTIC:CP$(CP)2:2418:B:MODE_STRING") #! Record("CTIC:CP$(CP)2:2418:B:PMOD",1922,2506,0,1,"CTIC:CP$(CP)2:2418:B:PMOD") #! Record("CTIC:CP$(CP)2:2418:B:IMOD",3020,2506,0,1,"CTIC:CP$(CP)2:2418:B:IMOD") #! Record("CTIC:CP$(CP)2:2418:B:ACTUATOR",1920,2322,0,1,"CTIC:CP$(CP)2:2418:B:ACTUATOR") #! Record("CTIC:CP$(CP)2:2418:B:PVAL",3000,2312,0,1,"CTIC:CP$(CP)2:2418:B:PVAL") #! Record("CTIC:CP$(CP)2:2418:B:CMD",3021,2112,0,1,"CTIC:CP$(CP)2:2418:B:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCTIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2418:B location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CTIC:CP$(CP)2:2465:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2465:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2465:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465.CVAL") field(PREC, "2") field(EGU, "K") field(ADEL, ".01") } record(ao, "CTIC:CP$(CP)2:2465:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2465:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2465:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2465:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2465:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2465:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2465:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2465:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CTIC:CP$(CP)2:2465:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2465:SP_RQST") { field(DESC, "C$(CP)TIC22465 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465_OVH.SP_Rqst") field(PREC, "2") field(EGU, "K") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2465:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CTIC:CP$(CP)2:2465:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)TIC22465") } record(ao, "CTIC:CP$(CP)2:2465:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2465:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CTIC:CP$(CP)2:2465:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CTIC:CP$(CP)2:2465:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CTIC:CP$(CP)2:2465:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CTIC:CP$(CP)2:2465:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2465:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2465:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CTIC:CP$(CP)2:2465:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CTIC:CP$(CP)2:2465:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CTIC:CP$(CP)2:2465:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CTIC:CP$(CP)2:2465:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CTIC:CP$(CP)2:2465:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465_OVH.Mode_String") } record(bi, "CTIC:CP$(CP)2:2465:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CTIC:CP$(CP)2:2465:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CTIC:CP$(CP)2:2465:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "EHTR22465") } record(ai, "CTIC:CP$(CP)2:2465:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22465.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CTIC:CP$(CP)2:2465:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22465.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CTIC:CP$(CP)2:2465:ORBV",2100,2312,0,1,"CTIC:CP$(CP)2:2465:ORBV") #! Record("CTIC:CP$(CP)2:2465:OVAL",2280,2312,0,1,"CTIC:CP$(CP)2:2465:OVAL") #! Record("CTIC:CP$(CP)2:2465:CVAL",2460,2312,0,1,"CTIC:CP$(CP)2:2465:CVAL") #! Record("CTIC:CP$(CP)2:2465:MAX",2122,1932,0,1,"CTIC:CP$(CP)2:2465:MAX") #! Record("CTIC:CP$(CP)2:2465:DMIN",2300,1932,0,1,"CTIC:CP$(CP)2:2465:DMIN") #! Record("CTIC:CP$(CP)2:2465:DMAX",2479,1932,0,1,"CTIC:CP$(CP)2:2465:DMAX") #! Record("CTIC:CP$(CP)2:2465:MODE_RQST",1760,2112,0,1,"CTIC:CP$(CP)2:2465:MODE_RQST") #! Record("CTIC:CP$(CP)2:2465:MDT",2120,2112,0,1,"CTIC:CP$(CP)2:2465:MDT") #! Record("CTIC:CP$(CP)2:2465:KP",2300,2106,0,1,"CTIC:CP$(CP)2:2465:KP") #! Record("CTIC:CP$(CP)2:2465:KI",2480,2106,0,1,"CTIC:CP$(CP)2:2465:KI") #! Record("CTIC:CP$(CP)2:2465:KD",2660,2106,0,1,"CTIC:CP$(CP)2:2465:KD") #! Record("CTIC:CP$(CP)2:2465:S",2840,2120,0,1,"CTIC:CP$(CP)2:2465:S") #! Record("CTIC:CP$(CP)2:2465:SP_RQST",1760,1932,0,1,"CTIC:CP$(CP)2:2465:SP_RQST") #! Record("CTIC:CP$(CP)2:2465:MIN",1945,1932,0,1,"CTIC:CP$(CP)2:2465:MIN") #! Record("CTIC:CP$(CP)2:2465:PIDTAG",1740,2462,0,1,"CTIC:CP$(CP)2:2465:PIDTAG") #! Record("CTIC:CP$(CP)2:2465:PEVAL",2660,1932,0,1,"CTIC:CP$(CP)2:2465:PEVAL") #! Record("CTIC:CP$(CP)2:2465:FSB",2840,1932,0,1,"CTIC:CP$(CP)2:2465:FSB") #! Record("CTIC:CP$(CP)2:2465:NOMATCH",2640,2506,0,1,"CTIC:CP$(CP)2:2465:NOMATCH") #! Record("CTIC:CP$(CP)2:2465:CHFAULT",2820,2506,0,1,"CTIC:CP$(CP)2:2465:CHFAULT") #! Record("CTIC:CP$(CP)2:2465:MANPOS_RQST",1940,2112,0,1,"CTIC:CP$(CP)2:2465:MANPOS_RQST") #! Record("CTIC:CP$(CP)2:2465:MODE_STATUS",1740,2639,0,1,"CTIC:CP$(CP)2:2465:MODE_STATUS") #! Record("CTIC:CP$(CP)2:2465:INTERLOCKED",2460,2686,0,0,"CTIC:CP$(CP)2:2465:INTERLOCKED") #! Record("CTIC:CP$(CP)2:2465:INTERLOCK",2460,2506,0,0,"CTIC:CP$(CP)2:2465:INTERLOCK") #! Record("CTIC:CP$(CP)2:2465:IVAL",2641,2312,0,1,"CTIC:CP$(CP)2:2465:IVAL") #! Record("CTIC:CP$(CP)2:2465:SVAL",2820,2312,0,1,"CTIC:CP$(CP)2:2465:SVAL") #! Record("CTIC:CP$(CP)2:2465:MMOD",2102,2506,0,1,"CTIC:CP$(CP)2:2465:MMOD") #! Record("CTIC:CP$(CP)2:2465:SMOD",2282,2506,0,1,"CTIC:CP$(CP)2:2465:SMOD") #! Record("CTIC:CP$(CP)2:2465:MODE_STRING",1740,2314,0,1,"CTIC:CP$(CP)2:2465:MODE_STRING") #! Record("CTIC:CP$(CP)2:2465:PMOD",1922,2506,0,1,"CTIC:CP$(CP)2:2465:PMOD") #! Record("CTIC:CP$(CP)2:2465:IMOD",3020,2506,0,1,"CTIC:CP$(CP)2:2465:IMOD") #! Record("CTIC:CP$(CP)2:2465:ACTUATOR",1920,2322,0,1,"CTIC:CP$(CP)2:2465:ACTUATOR") #! Record("CTIC:CP$(CP)2:2465:PVAL",3000,2312,0,1,"CTIC:CP$(CP)2:2465:PVAL") #! Record("CTIC:CP$(CP)2:2465:CMD",3021,2112,0,1,"CTIC:CP$(CP)2:2465:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCTIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2465 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)2:2405:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2405:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2405:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)2:2405:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2405:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2405:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2405:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2405:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2405:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2405:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2405:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)2:2405:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2405:SP_RQST") { field(DESC, "C$(CP)PIC22405 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2405:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)2:2405:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC22405") } record(ao, "CPIC:CP$(CP)2:2405:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2405:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)2:2405:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)2:2405:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)2:2405:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)2:2405:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2405:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2405:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)2:2405:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)2:2405:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)2:2405:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)2:2405:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)2:2405:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)2:2405:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)2:2405:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)2:2405:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22405") } record(ai, "CPIC:CP$(CP)2:2405:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22405.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)2:2405:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22405.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)2:2405:ORBV",2100,2312,0,1,"CPIC:CP$(CP)2:2405:ORBV") #! Record("CPIC:CP$(CP)2:2405:OVAL",2280,2312,0,1,"CPIC:CP$(CP)2:2405:OVAL") #! Record("CPIC:CP$(CP)2:2405:CVAL",2460,2312,0,1,"CPIC:CP$(CP)2:2405:CVAL") #! Record("CPIC:CP$(CP)2:2405:MAX",2122,1932,0,1,"CPIC:CP$(CP)2:2405:MAX") #! Record("CPIC:CP$(CP)2:2405:DMIN",2300,1932,0,1,"CPIC:CP$(CP)2:2405:DMIN") #! Record("CPIC:CP$(CP)2:2405:DMAX",2479,1932,0,1,"CPIC:CP$(CP)2:2405:DMAX") #! Record("CPIC:CP$(CP)2:2405:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)2:2405:MODE_RQST") #! Record("CPIC:CP$(CP)2:2405:MDT",2120,2112,0,1,"CPIC:CP$(CP)2:2405:MDT") #! Record("CPIC:CP$(CP)2:2405:KP",2300,2106,0,1,"CPIC:CP$(CP)2:2405:KP") #! Record("CPIC:CP$(CP)2:2405:KI",2480,2106,0,1,"CPIC:CP$(CP)2:2405:KI") #! Record("CPIC:CP$(CP)2:2405:KD",2660,2106,0,1,"CPIC:CP$(CP)2:2405:KD") #! Record("CPIC:CP$(CP)2:2405:S",2840,2120,0,1,"CPIC:CP$(CP)2:2405:S") #! Record("CPIC:CP$(CP)2:2405:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)2:2405:SP_RQST") #! Record("CPIC:CP$(CP)2:2405:MIN",1945,1932,0,1,"CPIC:CP$(CP)2:2405:MIN") #! Record("CPIC:CP$(CP)2:2405:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)2:2405:PIDTAG") #! Record("CPIC:CP$(CP)2:2405:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)2:2405:PEVAL") #! Record("CPIC:CP$(CP)2:2405:FSB",2840,1932,0,1,"CPIC:CP$(CP)2:2405:FSB") #! Record("CPIC:CP$(CP)2:2405:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)2:2405:NOMATCH") #! Record("CPIC:CP$(CP)2:2405:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)2:2405:CHFAULT") #! Record("CPIC:CP$(CP)2:2405:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)2:2405:MANPOS_RQST") #! Record("CPIC:CP$(CP)2:2405:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)2:2405:MODE_STATUS") #! Record("CPIC:CP$(CP)2:2405:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)2:2405:INTERLOCKED") #! Record("CPIC:CP$(CP)2:2405:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)2:2405:INTERLOCK") #! Record("CPIC:CP$(CP)2:2405:IVAL",2641,2312,0,1,"CPIC:CP$(CP)2:2405:IVAL") #! Record("CPIC:CP$(CP)2:2405:SVAL",2820,2312,0,1,"CPIC:CP$(CP)2:2405:SVAL") #! Record("CPIC:CP$(CP)2:2405:MMOD",2102,2506,0,1,"CPIC:CP$(CP)2:2405:MMOD") #! Record("CPIC:CP$(CP)2:2405:SMOD",2282,2506,0,1,"CPIC:CP$(CP)2:2405:SMOD") #! Record("CPIC:CP$(CP)2:2405:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)2:2405:MODE_STRING") #! Record("CPIC:CP$(CP)2:2405:PMOD",1922,2506,0,1,"CPIC:CP$(CP)2:2405:PMOD") #! Record("CPIC:CP$(CP)2:2405:IMOD",3020,2506,0,1,"CPIC:CP$(CP)2:2405:IMOD") #! Record("CPIC:CP$(CP)2:2405:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)2:2405:ACTUATOR") #! Record("CPIC:CP$(CP)2:2405:PVAL",3000,2312,0,1,"CPIC:CP$(CP)2:2405:PVAL") #! Record("CPIC:CP$(CP)2:2405:CMD",3021,2112,0,1,"CPIC:CP$(CP)2:2405:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2405 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CTIC:CP$(CP)2:2400:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2400:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2400:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400.CVAL") field(PREC, "2") field(EGU, "K") field(ADEL, ".01") } record(ao, "CTIC:CP$(CP)2:2400:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2400:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2400:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2400:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2400:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2400:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2400:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2400:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CTIC:CP$(CP)2:2400:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2400:SP_RQST") { field(DESC, "C$(CP)TIC22400 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400_OVH.SP_Rqst") field(PREC, "2") field(EGU, "K") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2400:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CTIC:CP$(CP)2:2400:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)TIC22400") } record(ao, "CTIC:CP$(CP)2:2400:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2400:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CTIC:CP$(CP)2:2400:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CTIC:CP$(CP)2:2400:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CTIC:CP$(CP)2:2400:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CTIC:CP$(CP)2:2400:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2400:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2400:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CTIC:CP$(CP)2:2400:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CTIC:CP$(CP)2:2400:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CTIC:CP$(CP)2:2400:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CTIC:CP$(CP)2:2400:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CTIC:CP$(CP)2:2400:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400_OVH.Mode_String") } record(bi, "CTIC:CP$(CP)2:2400:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CTIC:CP$(CP)2:2400:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CTIC:CP$(CP)2:2400:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22400/PV22402") } record(ai, "CTIC:CP$(CP)2:2400:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) TIC22400.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CTIC:CP$(CP)2:2400:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) TIC22400.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CTIC:CP$(CP)2:2400:ORBV",2100,2312,0,1,"CTIC:CP$(CP)2:2400:ORBV") #! Record("CTIC:CP$(CP)2:2400:OVAL",2280,2312,0,1,"CTIC:CP$(CP)2:2400:OVAL") #! Record("CTIC:CP$(CP)2:2400:CVAL",2460,2312,0,1,"CTIC:CP$(CP)2:2400:CVAL") #! Record("CTIC:CP$(CP)2:2400:MAX",2122,1932,0,1,"CTIC:CP$(CP)2:2400:MAX") #! Record("CTIC:CP$(CP)2:2400:DMIN",2300,1932,0,1,"CTIC:CP$(CP)2:2400:DMIN") #! Record("CTIC:CP$(CP)2:2400:DMAX",2479,1932,0,1,"CTIC:CP$(CP)2:2400:DMAX") #! Record("CTIC:CP$(CP)2:2400:MODE_RQST",1760,2112,0,1,"CTIC:CP$(CP)2:2400:MODE_RQST") #! Record("CTIC:CP$(CP)2:2400:MDT",2120,2112,0,1,"CTIC:CP$(CP)2:2400:MDT") #! Record("CTIC:CP$(CP)2:2400:KP",2300,2106,0,1,"CTIC:CP$(CP)2:2400:KP") #! Record("CTIC:CP$(CP)2:2400:KI",2480,2106,0,1,"CTIC:CP$(CP)2:2400:KI") #! Record("CTIC:CP$(CP)2:2400:KD",2660,2106,0,1,"CTIC:CP$(CP)2:2400:KD") #! Record("CTIC:CP$(CP)2:2400:S",2840,2120,0,1,"CTIC:CP$(CP)2:2400:S") #! Record("CTIC:CP$(CP)2:2400:SP_RQST",1760,1932,0,1,"CTIC:CP$(CP)2:2400:SP_RQST") #! Record("CTIC:CP$(CP)2:2400:MIN",1945,1932,0,1,"CTIC:CP$(CP)2:2400:MIN") #! Record("CTIC:CP$(CP)2:2400:PIDTAG",1740,2462,0,1,"CTIC:CP$(CP)2:2400:PIDTAG") #! Record("CTIC:CP$(CP)2:2400:PEVAL",2660,1932,0,1,"CTIC:CP$(CP)2:2400:PEVAL") #! Record("CTIC:CP$(CP)2:2400:FSB",2840,1932,0,1,"CTIC:CP$(CP)2:2400:FSB") #! Record("CTIC:CP$(CP)2:2400:NOMATCH",2640,2506,0,1,"CTIC:CP$(CP)2:2400:NOMATCH") #! Record("CTIC:CP$(CP)2:2400:CHFAULT",2820,2506,0,1,"CTIC:CP$(CP)2:2400:CHFAULT") #! Record("CTIC:CP$(CP)2:2400:MANPOS_RQST",1940,2112,0,1,"CTIC:CP$(CP)2:2400:MANPOS_RQST") #! Record("CTIC:CP$(CP)2:2400:MODE_STATUS",1740,2639,0,1,"CTIC:CP$(CP)2:2400:MODE_STATUS") #! Record("CTIC:CP$(CP)2:2400:INTERLOCKED",2460,2686,0,0,"CTIC:CP$(CP)2:2400:INTERLOCKED") #! Record("CTIC:CP$(CP)2:2400:INTERLOCK",2460,2506,0,0,"CTIC:CP$(CP)2:2400:INTERLOCK") #! Record("CTIC:CP$(CP)2:2400:IVAL",2641,2312,0,1,"CTIC:CP$(CP)2:2400:IVAL") #! Record("CTIC:CP$(CP)2:2400:SVAL",2820,2312,0,1,"CTIC:CP$(CP)2:2400:SVAL") #! Record("CTIC:CP$(CP)2:2400:MMOD",2102,2506,0,1,"CTIC:CP$(CP)2:2400:MMOD") #! Record("CTIC:CP$(CP)2:2400:SMOD",2282,2506,0,1,"CTIC:CP$(CP)2:2400:SMOD") #! Record("CTIC:CP$(CP)2:2400:MODE_STRING",1740,2314,0,1,"CTIC:CP$(CP)2:2400:MODE_STRING") #! Record("CTIC:CP$(CP)2:2400:PMOD",1922,2506,0,1,"CTIC:CP$(CP)2:2400:PMOD") #! Record("CTIC:CP$(CP)2:2400:IMOD",3020,2506,0,1,"CTIC:CP$(CP)2:2400:IMOD") #! Record("CTIC:CP$(CP)2:2400:ACTUATOR",1920,2322,0,1,"CTIC:CP$(CP)2:2400:ACTUATOR") #! Record("CTIC:CP$(CP)2:2400:PVAL",3000,2312,0,1,"CTIC:CP$(CP)2:2400:PVAL") #! Record("CTIC:CP$(CP)2:2400:CMD",3021,2112,0,1,"CTIC:CP$(CP)2:2400:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCTIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2400 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CLIC:CP$(CP)2:2520:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CLIC:CP$(CP)2:2520:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CLIC:CP$(CP)2:2520:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520.CVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ao, "CLIC:CP$(CP)2:2520:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2520:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2520:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CLIC:CP$(CP)2:2520:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2520:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2520:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2520:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2520:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CLIC:CP$(CP)2:2520:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2520:SP_RQST") { field(DESC, "C$(CP)LIC22520 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520_OVH.SP_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2520:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CLIC:CP$(CP)2:2520:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)LIC22520") } record(ao, "CLIC:CP$(CP)2:2520:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CLIC:CP$(CP)2:2520:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CLIC:CP$(CP)2:2520:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CLIC:CP$(CP)2:2520:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CLIC:CP$(CP)2:2520:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CLIC:CP$(CP)2:2520:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CLIC:CP$(CP)2:2520:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CLIC:CP$(CP)2:2520:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CLIC:CP$(CP)2:2520:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CLIC:CP$(CP)2:2520:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CLIC:CP$(CP)2:2520:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CLIC:CP$(CP)2:2520:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CLIC:CP$(CP)2:2520:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520_OVH.Mode_String") } record(bi, "CLIC:CP$(CP)2:2520:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CLIC:CP$(CP)2:2520:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CLIC:CP$(CP)2:2520:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22520") } record(ai, "CLIC:CP$(CP)2:2520:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22520.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CLIC:CP$(CP)2:2520:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22520.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CLIC:CP$(CP)2:2520:ORBV",2100,2312,0,1,"CLIC:CP$(CP)2:2520:ORBV") #! Record("CLIC:CP$(CP)2:2520:OVAL",2280,2312,0,1,"CLIC:CP$(CP)2:2520:OVAL") #! Record("CLIC:CP$(CP)2:2520:CVAL",2460,2312,0,1,"CLIC:CP$(CP)2:2520:CVAL") #! Record("CLIC:CP$(CP)2:2520:MAX",2122,1932,0,1,"CLIC:CP$(CP)2:2520:MAX") #! Record("CLIC:CP$(CP)2:2520:DMIN",2300,1932,0,1,"CLIC:CP$(CP)2:2520:DMIN") #! Record("CLIC:CP$(CP)2:2520:DMAX",2479,1932,0,1,"CLIC:CP$(CP)2:2520:DMAX") #! Record("CLIC:CP$(CP)2:2520:MODE_RQST",1760,2112,0,1,"CLIC:CP$(CP)2:2520:MODE_RQST") #! Record("CLIC:CP$(CP)2:2520:MDT",2120,2112,0,1,"CLIC:CP$(CP)2:2520:MDT") #! Record("CLIC:CP$(CP)2:2520:KP",2300,2106,0,1,"CLIC:CP$(CP)2:2520:KP") #! Record("CLIC:CP$(CP)2:2520:KI",2480,2106,0,1,"CLIC:CP$(CP)2:2520:KI") #! Record("CLIC:CP$(CP)2:2520:KD",2660,2106,0,1,"CLIC:CP$(CP)2:2520:KD") #! Record("CLIC:CP$(CP)2:2520:S",2840,2120,0,1,"CLIC:CP$(CP)2:2520:S") #! Record("CLIC:CP$(CP)2:2520:SP_RQST",1760,1932,0,1,"CLIC:CP$(CP)2:2520:SP_RQST") #! Record("CLIC:CP$(CP)2:2520:MIN",1945,1932,0,1,"CLIC:CP$(CP)2:2520:MIN") #! Record("CLIC:CP$(CP)2:2520:PIDTAG",1740,2462,0,1,"CLIC:CP$(CP)2:2520:PIDTAG") #! Record("CLIC:CP$(CP)2:2520:PEVAL",2660,1932,0,1,"CLIC:CP$(CP)2:2520:PEVAL") #! Record("CLIC:CP$(CP)2:2520:FSB",2840,1932,0,1,"CLIC:CP$(CP)2:2520:FSB") #! Record("CLIC:CP$(CP)2:2520:NOMATCH",2640,2506,0,1,"CLIC:CP$(CP)2:2520:NOMATCH") #! Record("CLIC:CP$(CP)2:2520:CHFAULT",2820,2506,0,1,"CLIC:CP$(CP)2:2520:CHFAULT") #! Record("CLIC:CP$(CP)2:2520:MANPOS_RQST",1940,2112,0,1,"CLIC:CP$(CP)2:2520:MANPOS_RQST") #! Record("CLIC:CP$(CP)2:2520:MODE_STATUS",1740,2639,0,1,"CLIC:CP$(CP)2:2520:MODE_STATUS") #! Record("CLIC:CP$(CP)2:2520:INTERLOCKED",2460,2686,0,0,"CLIC:CP$(CP)2:2520:INTERLOCKED") #! Record("CLIC:CP$(CP)2:2520:INTERLOCK",2460,2506,0,0,"CLIC:CP$(CP)2:2520:INTERLOCK") #! Record("CLIC:CP$(CP)2:2520:IVAL",2641,2312,0,1,"CLIC:CP$(CP)2:2520:IVAL") #! Record("CLIC:CP$(CP)2:2520:SVAL",2820,2312,0,1,"CLIC:CP$(CP)2:2520:SVAL") #! Record("CLIC:CP$(CP)2:2520:MMOD",2102,2506,0,1,"CLIC:CP$(CP)2:2520:MMOD") #! Record("CLIC:CP$(CP)2:2520:SMOD",2282,2506,0,1,"CLIC:CP$(CP)2:2520:SMOD") #! Record("CLIC:CP$(CP)2:2520:MODE_STRING",1740,2314,0,1,"CLIC:CP$(CP)2:2520:MODE_STRING") #! Record("CLIC:CP$(CP)2:2520:PMOD",1922,2506,0,1,"CLIC:CP$(CP)2:2520:PMOD") #! Record("CLIC:CP$(CP)2:2520:IMOD",3020,2506,0,1,"CLIC:CP$(CP)2:2520:IMOD") #! Record("CLIC:CP$(CP)2:2520:ACTUATOR",1920,2322,0,1,"CLIC:CP$(CP)2:2520:ACTUATOR") #! Record("CLIC:CP$(CP)2:2520:PVAL",3000,2312,0,1,"CLIC:CP$(CP)2:2520:PVAL") #! Record("CLIC:CP$(CP)2:2520:CMD",3021,2112,0,1,"CLIC:CP$(CP)2:2520:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCLIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2520 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CDPC:CP$(CP)2:2242:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CDPC:CP$(CP)2:2242:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CDPC:CP$(CP)2:2242:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242.CVAL") field(PREC, "2") field(EGU, "mbar") field(ADEL, ".01") } record(ao, "CDPC:CP$(CP)2:2242:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2242:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2242:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CDPC:CP$(CP)2:2242:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2242:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2242:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2242:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2242:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CDPC:CP$(CP)2:2242:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2242:SP_RQST") { field(DESC, "C$(CP)DPIC22242 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242_OVH.SP_Rqst") field(PREC, "2") field(EGU, "mbar") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2242:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CDPC:CP$(CP)2:2242:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)DPIC22242") } record(ao, "CDPC:CP$(CP)2:2242:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CDPC:CP$(CP)2:2242:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CDPC:CP$(CP)2:2242:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CDPC:CP$(CP)2:2242:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CDPC:CP$(CP)2:2242:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CDPC:CP$(CP)2:2242:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CDPC:CP$(CP)2:2242:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CDPC:CP$(CP)2:2242:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CDPC:CP$(CP)2:2242:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CDPC:CP$(CP)2:2242:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CDPC:CP$(CP)2:2242:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CDPC:CP$(CP)2:2242:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CDPC:CP$(CP)2:2242:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242_OVH.Mode_String") } record(bi, "CDPC:CP$(CP)2:2242:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CDPC:CP$(CP)2:2242:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CDPC:CP$(CP)2:2242:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22242") } record(ai, "CDPC:CP$(CP)2:2242:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22242.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CDPC:CP$(CP)2:2242:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22242.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CDPC:CP$(CP)2:2242:ORBV",2100,2312,0,1,"CDPC:CP$(CP)2:2242:ORBV") #! Record("CDPC:CP$(CP)2:2242:OVAL",2280,2312,0,1,"CDPC:CP$(CP)2:2242:OVAL") #! Record("CDPC:CP$(CP)2:2242:CVAL",2460,2312,0,1,"CDPC:CP$(CP)2:2242:CVAL") #! Record("CDPC:CP$(CP)2:2242:MAX",2122,1932,0,1,"CDPC:CP$(CP)2:2242:MAX") #! Record("CDPC:CP$(CP)2:2242:DMIN",2300,1932,0,1,"CDPC:CP$(CP)2:2242:DMIN") #! Record("CDPC:CP$(CP)2:2242:DMAX",2479,1932,0,1,"CDPC:CP$(CP)2:2242:DMAX") #! Record("CDPC:CP$(CP)2:2242:MODE_RQST",1760,2112,0,1,"CDPC:CP$(CP)2:2242:MODE_RQST") #! Record("CDPC:CP$(CP)2:2242:MDT",2120,2112,0,1,"CDPC:CP$(CP)2:2242:MDT") #! Record("CDPC:CP$(CP)2:2242:KP",2300,2106,0,1,"CDPC:CP$(CP)2:2242:KP") #! Record("CDPC:CP$(CP)2:2242:KI",2480,2106,0,1,"CDPC:CP$(CP)2:2242:KI") #! Record("CDPC:CP$(CP)2:2242:KD",2660,2106,0,1,"CDPC:CP$(CP)2:2242:KD") #! Record("CDPC:CP$(CP)2:2242:S",2840,2120,0,1,"CDPC:CP$(CP)2:2242:S") #! Record("CDPC:CP$(CP)2:2242:SP_RQST",1760,1932,0,1,"CDPC:CP$(CP)2:2242:SP_RQST") #! Record("CDPC:CP$(CP)2:2242:MIN",1945,1932,0,1,"CDPC:CP$(CP)2:2242:MIN") #! Record("CDPC:CP$(CP)2:2242:PIDTAG",1740,2462,0,1,"CDPC:CP$(CP)2:2242:PIDTAG") #! Record("CDPC:CP$(CP)2:2242:PEVAL",2660,1932,0,1,"CDPC:CP$(CP)2:2242:PEVAL") #! Record("CDPC:CP$(CP)2:2242:FSB",2840,1932,0,1,"CDPC:CP$(CP)2:2242:FSB") #! Record("CDPC:CP$(CP)2:2242:NOMATCH",2640,2506,0,1,"CDPC:CP$(CP)2:2242:NOMATCH") #! Record("CDPC:CP$(CP)2:2242:CHFAULT",2820,2506,0,1,"CDPC:CP$(CP)2:2242:CHFAULT") #! Record("CDPC:CP$(CP)2:2242:MANPOS_RQST",1940,2112,0,1,"CDPC:CP$(CP)2:2242:MANPOS_RQST") #! Record("CDPC:CP$(CP)2:2242:MODE_STATUS",1740,2639,0,1,"CDPC:CP$(CP)2:2242:MODE_STATUS") #! Record("CDPC:CP$(CP)2:2242:INTERLOCKED",2460,2686,0,0,"CDPC:CP$(CP)2:2242:INTERLOCKED") #! Record("CDPC:CP$(CP)2:2242:INTERLOCK",2460,2506,0,0,"CDPC:CP$(CP)2:2242:INTERLOCK") #! Record("CDPC:CP$(CP)2:2242:IVAL",2641,2312,0,1,"CDPC:CP$(CP)2:2242:IVAL") #! Record("CDPC:CP$(CP)2:2242:SVAL",2820,2312,0,1,"CDPC:CP$(CP)2:2242:SVAL") #! Record("CDPC:CP$(CP)2:2242:MMOD",2102,2506,0,1,"CDPC:CP$(CP)2:2242:MMOD") #! Record("CDPC:CP$(CP)2:2242:SMOD",2282,2506,0,1,"CDPC:CP$(CP)2:2242:SMOD") #! Record("CDPC:CP$(CP)2:2242:MODE_STRING",1740,2314,0,1,"CDPC:CP$(CP)2:2242:MODE_STRING") #! Record("CDPC:CP$(CP)2:2242:PMOD",1922,2506,0,1,"CDPC:CP$(CP)2:2242:PMOD") #! Record("CDPC:CP$(CP)2:2242:IMOD",3020,2506,0,1,"CDPC:CP$(CP)2:2242:IMOD") #! Record("CDPC:CP$(CP)2:2242:ACTUATOR",1920,2322,0,1,"CDPC:CP$(CP)2:2242:ACTUATOR") #! Record("CDPC:CP$(CP)2:2242:PVAL",3000,2312,0,1,"CDPC:CP$(CP)2:2242:PVAL") #! Record("CDPC:CP$(CP)2:2242:CMD",3021,2112,0,1,"CDPC:CP$(CP)2:2242:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCDPC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2242 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CSIC:CP$(CP)2:2432:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CSIC:CP$(CP)2:2432:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CSIC:CP$(CP)2:2432:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432.CVAL") field(PREC, "2") field(EGU, "Hz") field(ADEL, ".01") } record(ao, "CSIC:CP$(CP)2:2432:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2432:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2432:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CSIC:CP$(CP)2:2432:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2432:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2432:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2432:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2432:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CSIC:CP$(CP)2:2432:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2432:SP_RQST") { field(DESC, "C$(CP)SIC22432 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432_OVH.SP_Rqst") field(PREC, "2") field(EGU, "Hz") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2432:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CSIC:CP$(CP)2:2432:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)SIC22432") } record(ao, "CSIC:CP$(CP)2:2432:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CSIC:CP$(CP)2:2432:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CSIC:CP$(CP)2:2432:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CSIC:CP$(CP)2:2432:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CSIC:CP$(CP)2:2432:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CSIC:CP$(CP)2:2432:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CSIC:CP$(CP)2:2432:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CSIC:CP$(CP)2:2432:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CSIC:CP$(CP)2:2432:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CSIC:CP$(CP)2:2432:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CSIC:CP$(CP)2:2432:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CSIC:CP$(CP)2:2432:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CSIC:CP$(CP)2:2432:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432_OVH.Mode_String") } record(bi, "CSIC:CP$(CP)2:2432:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CSIC:CP$(CP)2:2432:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CSIC:CP$(CP)2:2432:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22432") } record(ai, "CSIC:CP$(CP)2:2432:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CSIC:CP$(CP)2:2432:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CSIC:CP$(CP)2:2432:ORBV",2100,2312,0,1,"CSIC:CP$(CP)2:2432:ORBV") #! Record("CSIC:CP$(CP)2:2432:OVAL",2280,2312,0,1,"CSIC:CP$(CP)2:2432:OVAL") #! Record("CSIC:CP$(CP)2:2432:CVAL",2460,2312,0,1,"CSIC:CP$(CP)2:2432:CVAL") #! Record("CSIC:CP$(CP)2:2432:MAX",2122,1932,0,1,"CSIC:CP$(CP)2:2432:MAX") #! Record("CSIC:CP$(CP)2:2432:DMIN",2300,1932,0,1,"CSIC:CP$(CP)2:2432:DMIN") #! Record("CSIC:CP$(CP)2:2432:DMAX",2479,1932,0,1,"CSIC:CP$(CP)2:2432:DMAX") #! Record("CSIC:CP$(CP)2:2432:MODE_RQST",1760,2112,0,1,"CSIC:CP$(CP)2:2432:MODE_RQST") #! Record("CSIC:CP$(CP)2:2432:MDT",2120,2112,0,1,"CSIC:CP$(CP)2:2432:MDT") #! Record("CSIC:CP$(CP)2:2432:KP",2300,2106,0,1,"CSIC:CP$(CP)2:2432:KP") #! Record("CSIC:CP$(CP)2:2432:KI",2480,2106,0,1,"CSIC:CP$(CP)2:2432:KI") #! Record("CSIC:CP$(CP)2:2432:KD",2660,2106,0,1,"CSIC:CP$(CP)2:2432:KD") #! Record("CSIC:CP$(CP)2:2432:S",2840,2120,0,1,"CSIC:CP$(CP)2:2432:S") #! Record("CSIC:CP$(CP)2:2432:SP_RQST",1760,1932,0,1,"CSIC:CP$(CP)2:2432:SP_RQST") #! Record("CSIC:CP$(CP)2:2432:MIN",1945,1932,0,1,"CSIC:CP$(CP)2:2432:MIN") #! Record("CSIC:CP$(CP)2:2432:PIDTAG",1740,2462,0,1,"CSIC:CP$(CP)2:2432:PIDTAG") #! Record("CSIC:CP$(CP)2:2432:PEVAL",2660,1932,0,1,"CSIC:CP$(CP)2:2432:PEVAL") #! Record("CSIC:CP$(CP)2:2432:FSB",2840,1932,0,1,"CSIC:CP$(CP)2:2432:FSB") #! Record("CSIC:CP$(CP)2:2432:NOMATCH",2640,2506,0,1,"CSIC:CP$(CP)2:2432:NOMATCH") #! Record("CSIC:CP$(CP)2:2432:CHFAULT",2820,2506,0,1,"CSIC:CP$(CP)2:2432:CHFAULT") #! Record("CSIC:CP$(CP)2:2432:MANPOS_RQST",1940,2112,0,1,"CSIC:CP$(CP)2:2432:MANPOS_RQST") #! Record("CSIC:CP$(CP)2:2432:MODE_STATUS",1740,2639,0,1,"CSIC:CP$(CP)2:2432:MODE_STATUS") #! Record("CSIC:CP$(CP)2:2432:INTERLOCKED",2460,2686,0,0,"CSIC:CP$(CP)2:2432:INTERLOCKED") #! Record("CSIC:CP$(CP)2:2432:INTERLOCK",2460,2506,0,0,"CSIC:CP$(CP)2:2432:INTERLOCK") #! Record("CSIC:CP$(CP)2:2432:IVAL",2641,2312,0,1,"CSIC:CP$(CP)2:2432:IVAL") #! Record("CSIC:CP$(CP)2:2432:SVAL",2820,2312,0,1,"CSIC:CP$(CP)2:2432:SVAL") #! Record("CSIC:CP$(CP)2:2432:MMOD",2102,2506,0,1,"CSIC:CP$(CP)2:2432:MMOD") #! Record("CSIC:CP$(CP)2:2432:SMOD",2282,2506,0,1,"CSIC:CP$(CP)2:2432:SMOD") #! Record("CSIC:CP$(CP)2:2432:MODE_STRING",1740,2314,0,1,"CSIC:CP$(CP)2:2432:MODE_STRING") #! Record("CSIC:CP$(CP)2:2432:PMOD",1922,2506,0,1,"CSIC:CP$(CP)2:2432:PMOD") #! Record("CSIC:CP$(CP)2:2432:IMOD",3020,2506,0,1,"CSIC:CP$(CP)2:2432:IMOD") #! Record("CSIC:CP$(CP)2:2432:ACTUATOR",1920,2322,0,1,"CSIC:CP$(CP)2:2432:ACTUATOR") #! Record("CSIC:CP$(CP)2:2432:PVAL",3000,2312,0,1,"CSIC:CP$(CP)2:2432:PVAL") #! Record("CSIC:CP$(CP)2:2432:CMD",3021,2112,0,1,"CSIC:CP$(CP)2:2432:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCSIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2432 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CTIC:CP$(CP)2:2432:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2432:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2432:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A.CVAL") field(PREC, "2") field(EGU, "K") field(ADEL, ".01") } record(ao, "CTIC:CP$(CP)2:2432:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2432:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2432:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2432:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2432:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2432:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2432:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2432:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CTIC:CP$(CP)2:2432:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2432:SP_RQST") { field(DESC, "C$(CP)TIC22332 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A_OVH.SP_Rqst") field(PREC, "2") field(EGU, "K") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2432:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CTIC:CP$(CP)2:2432:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)TIC22332") } record(ao, "CTIC:CP$(CP)2:2432:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2432:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CTIC:CP$(CP)2:2432:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CTIC:CP$(CP)2:2432:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CTIC:CP$(CP)2:2432:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CTIC:CP$(CP)2:2432:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2432:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2432:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CTIC:CP$(CP)2:2432:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CTIC:CP$(CP)2:2432:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CTIC:CP$(CP)2:2432:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CTIC:CP$(CP)2:2432:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CTIC:CP$(CP)2:2432:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A_OVH.Mode_String") } record(bi, "CTIC:CP$(CP)2:2432:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CTIC:CP$(CP)2:2432:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CTIC:CP$(CP)2:2432:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22432A") } record(ai, "CTIC:CP$(CP)2:2432:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22432A.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CTIC:CP$(CP)2:2432:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22432A.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CTIC:CP$(CP)2:2432:ORBV",2100,2312,0,1,"CTIC:CP$(CP)2:2432:ORBV") #! Record("CTIC:CP$(CP)2:2432:OVAL",2280,2312,0,1,"CTIC:CP$(CP)2:2432:OVAL") #! Record("CTIC:CP$(CP)2:2432:CVAL",2460,2312,0,1,"CTIC:CP$(CP)2:2432:CVAL") #! Record("CTIC:CP$(CP)2:2432:MAX",2122,1932,0,1,"CTIC:CP$(CP)2:2432:MAX") #! Record("CTIC:CP$(CP)2:2432:DMIN",2300,1932,0,1,"CTIC:CP$(CP)2:2432:DMIN") #! Record("CTIC:CP$(CP)2:2432:DMAX",2479,1932,0,1,"CTIC:CP$(CP)2:2432:DMAX") #! Record("CTIC:CP$(CP)2:2432:MODE_RQST",1760,2112,0,1,"CTIC:CP$(CP)2:2432:MODE_RQST") #! Record("CTIC:CP$(CP)2:2432:MDT",2120,2112,0,1,"CTIC:CP$(CP)2:2432:MDT") #! Record("CTIC:CP$(CP)2:2432:KP",2300,2106,0,1,"CTIC:CP$(CP)2:2432:KP") #! Record("CTIC:CP$(CP)2:2432:KI",2480,2106,0,1,"CTIC:CP$(CP)2:2432:KI") #! Record("CTIC:CP$(CP)2:2432:KD",2660,2106,0,1,"CTIC:CP$(CP)2:2432:KD") #! Record("CTIC:CP$(CP)2:2432:S",2840,2120,0,1,"CTIC:CP$(CP)2:2432:S") #! Record("CTIC:CP$(CP)2:2432:SP_RQST",1760,1932,0,1,"CTIC:CP$(CP)2:2432:SP_RQST") #! Record("CTIC:CP$(CP)2:2432:MIN",1945,1932,0,1,"CTIC:CP$(CP)2:2432:MIN") #! Record("CTIC:CP$(CP)2:2432:PIDTAG",1740,2462,0,1,"CTIC:CP$(CP)2:2432:PIDTAG") #! Record("CTIC:CP$(CP)2:2432:PEVAL",2660,1932,0,1,"CTIC:CP$(CP)2:2432:PEVAL") #! Record("CTIC:CP$(CP)2:2432:FSB",2840,1932,0,1,"CTIC:CP$(CP)2:2432:FSB") #! Record("CTIC:CP$(CP)2:2432:NOMATCH",2640,2506,0,1,"CTIC:CP$(CP)2:2432:NOMATCH") #! Record("CTIC:CP$(CP)2:2432:CHFAULT",2820,2506,0,1,"CTIC:CP$(CP)2:2432:CHFAULT") #! Record("CTIC:CP$(CP)2:2432:MANPOS_RQST",1940,2112,0,1,"CTIC:CP$(CP)2:2432:MANPOS_RQST") #! Record("CTIC:CP$(CP)2:2432:MODE_STATUS",1740,2639,0,1,"CTIC:CP$(CP)2:2432:MODE_STATUS") #! Record("CTIC:CP$(CP)2:2432:INTERLOCKED",2460,2686,0,0,"CTIC:CP$(CP)2:2432:INTERLOCKED") #! Record("CTIC:CP$(CP)2:2432:INTERLOCK",2460,2506,0,0,"CTIC:CP$(CP)2:2432:INTERLOCK") #! Record("CTIC:CP$(CP)2:2432:IVAL",2641,2312,0,1,"CTIC:CP$(CP)2:2432:IVAL") #! Record("CTIC:CP$(CP)2:2432:SVAL",2820,2312,0,1,"CTIC:CP$(CP)2:2432:SVAL") #! Record("CTIC:CP$(CP)2:2432:MMOD",2102,2506,0,1,"CTIC:CP$(CP)2:2432:MMOD") #! Record("CTIC:CP$(CP)2:2432:SMOD",2282,2506,0,1,"CTIC:CP$(CP)2:2432:SMOD") #! Record("CTIC:CP$(CP)2:2432:MODE_STRING",1740,2314,0,1,"CTIC:CP$(CP)2:2432:MODE_STRING") #! Record("CTIC:CP$(CP)2:2432:PMOD",1922,2506,0,1,"CTIC:CP$(CP)2:2432:PMOD") #! Record("CTIC:CP$(CP)2:2432:IMOD",3020,2506,0,1,"CTIC:CP$(CP)2:2432:IMOD") #! Record("CTIC:CP$(CP)2:2432:ACTUATOR",1920,2322,0,1,"CTIC:CP$(CP)2:2432:ACTUATOR") #! Record("CTIC:CP$(CP)2:2432:PVAL",3000,2312,0,1,"CTIC:CP$(CP)2:2432:PVAL") #! Record("CTIC:CP$(CP)2:2432:CMD",3021,2112,0,1,"CTIC:CP$(CP)2:2432:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCTIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2432 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CDPC:CP$(CP)2:2441:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CDPC:CP$(CP)2:2441:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CDPC:CP$(CP)2:2441:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441.CVAL") field(PREC, "2") field(EGU, "mbar") field(ADEL, ".01") } record(ao, "CDPC:CP$(CP)2:2441:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2441:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2441:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CDPC:CP$(CP)2:2441:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2441:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2441:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2441:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2441:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CDPC:CP$(CP)2:2441:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2441:SP_RQST") { field(DESC, "C$(CP)DPIC22441 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441_OVH.SP_Rqst") field(PREC, "2") field(EGU, "mbar") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CDPC:CP$(CP)2:2441:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CDPC:CP$(CP)2:2441:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)DPIC22441") } record(ao, "CDPC:CP$(CP)2:2441:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CDPC:CP$(CP)2:2441:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CDPC:CP$(CP)2:2441:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CDPC:CP$(CP)2:2441:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CDPC:CP$(CP)2:2441:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CDPC:CP$(CP)2:2441:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CDPC:CP$(CP)2:2441:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CDPC:CP$(CP)2:2441:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CDPC:CP$(CP)2:2441:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CDPC:CP$(CP)2:2441:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CDPC:CP$(CP)2:2441:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CDPC:CP$(CP)2:2441:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CDPC:CP$(CP)2:2441:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441_OVH.Mode_String") } record(bi, "CDPC:CP$(CP)2:2441:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CDPC:CP$(CP)2:2441:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CDPC:CP$(CP)2:2441:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22441") } record(ai, "CDPC:CP$(CP)2:2441:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22441.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CDPC:CP$(CP)2:2441:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22441.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CDPC:CP$(CP)2:2441:ORBV",2100,2312,0,1,"CDPC:CP$(CP)2:2441:ORBV") #! Record("CDPC:CP$(CP)2:2441:OVAL",2280,2312,0,1,"CDPC:CP$(CP)2:2441:OVAL") #! Record("CDPC:CP$(CP)2:2441:CVAL",2460,2312,0,1,"CDPC:CP$(CP)2:2441:CVAL") #! Record("CDPC:CP$(CP)2:2441:MAX",2122,1932,0,1,"CDPC:CP$(CP)2:2441:MAX") #! Record("CDPC:CP$(CP)2:2441:DMIN",2300,1932,0,1,"CDPC:CP$(CP)2:2441:DMIN") #! Record("CDPC:CP$(CP)2:2441:DMAX",2479,1932,0,1,"CDPC:CP$(CP)2:2441:DMAX") #! Record("CDPC:CP$(CP)2:2441:MODE_RQST",1760,2112,0,1,"CDPC:CP$(CP)2:2441:MODE_RQST") #! Record("CDPC:CP$(CP)2:2441:MDT",2120,2112,0,1,"CDPC:CP$(CP)2:2441:MDT") #! Record("CDPC:CP$(CP)2:2441:KP",2300,2106,0,1,"CDPC:CP$(CP)2:2441:KP") #! Record("CDPC:CP$(CP)2:2441:KI",2480,2106,0,1,"CDPC:CP$(CP)2:2441:KI") #! Record("CDPC:CP$(CP)2:2441:KD",2660,2106,0,1,"CDPC:CP$(CP)2:2441:KD") #! Record("CDPC:CP$(CP)2:2441:S",2840,2120,0,1,"CDPC:CP$(CP)2:2441:S") #! Record("CDPC:CP$(CP)2:2441:SP_RQST",1760,1932,0,1,"CDPC:CP$(CP)2:2441:SP_RQST") #! Record("CDPC:CP$(CP)2:2441:MIN",1945,1932,0,1,"CDPC:CP$(CP)2:2441:MIN") #! Record("CDPC:CP$(CP)2:2441:PIDTAG",1740,2462,0,1,"CDPC:CP$(CP)2:2441:PIDTAG") #! Record("CDPC:CP$(CP)2:2441:PEVAL",2660,1932,0,1,"CDPC:CP$(CP)2:2441:PEVAL") #! Record("CDPC:CP$(CP)2:2441:FSB",2840,1932,0,1,"CDPC:CP$(CP)2:2441:FSB") #! Record("CDPC:CP$(CP)2:2441:NOMATCH",2640,2506,0,1,"CDPC:CP$(CP)2:2441:NOMATCH") #! Record("CDPC:CP$(CP)2:2441:CHFAULT",2820,2506,0,1,"CDPC:CP$(CP)2:2441:CHFAULT") #! Record("CDPC:CP$(CP)2:2441:MANPOS_RQST",1940,2112,0,1,"CDPC:CP$(CP)2:2441:MANPOS_RQST") #! Record("CDPC:CP$(CP)2:2441:MODE_STATUS",1740,2639,0,1,"CDPC:CP$(CP)2:2441:MODE_STATUS") #! Record("CDPC:CP$(CP)2:2441:INTERLOCKED",2460,2686,0,0,"CDPC:CP$(CP)2:2441:INTERLOCKED") #! Record("CDPC:CP$(CP)2:2441:INTERLOCK",2460,2506,0,0,"CDPC:CP$(CP)2:2441:INTERLOCK") #! Record("CDPC:CP$(CP)2:2441:IVAL",2641,2312,0,1,"CDPC:CP$(CP)2:2441:IVAL") #! Record("CDPC:CP$(CP)2:2441:SVAL",2820,2312,0,1,"CDPC:CP$(CP)2:2441:SVAL") #! Record("CDPC:CP$(CP)2:2441:MMOD",2102,2506,0,1,"CDPC:CP$(CP)2:2441:MMOD") #! Record("CDPC:CP$(CP)2:2441:SMOD",2282,2506,0,1,"CDPC:CP$(CP)2:2441:SMOD") #! Record("CDPC:CP$(CP)2:2441:MODE_STRING",1740,2314,0,1,"CDPC:CP$(CP)2:2441:MODE_STRING") #! Record("CDPC:CP$(CP)2:2441:PMOD",1922,2506,0,1,"CDPC:CP$(CP)2:2441:PMOD") #! Record("CDPC:CP$(CP)2:2441:IMOD",3020,2506,0,1,"CDPC:CP$(CP)2:2441:IMOD") #! Record("CDPC:CP$(CP)2:2441:ACTUATOR",1920,2322,0,1,"CDPC:CP$(CP)2:2441:ACTUATOR") #! Record("CDPC:CP$(CP)2:2441:PVAL",3000,2312,0,1,"CDPC:CP$(CP)2:2441:PVAL") #! Record("CDPC:CP$(CP)2:2441:CMD",3021,2112,0,1,"CDPC:CP$(CP)2:2441:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCDPC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2441 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CSIC:CP$(CP)2:2452:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CSIC:CP$(CP)2:2452:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CSIC:CP$(CP)2:2452:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452.CVAL") field(PREC, "2") field(EGU, "Hz") field(ADEL, ".01") } record(ao, "CSIC:CP$(CP)2:2452:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2452:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2452:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CSIC:CP$(CP)2:2452:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2452:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2452:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2452:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2452:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CSIC:CP$(CP)2:2452:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2452:SP_RQST") { field(DESC, "C$(CP)SIC22452 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452_OVH.SP_Rqst") field(PREC, "2") field(EGU, "Hz") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2452:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CSIC:CP$(CP)2:2452:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)SIC22452") } record(ao, "CSIC:CP$(CP)2:2452:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CSIC:CP$(CP)2:2452:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CSIC:CP$(CP)2:2452:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CSIC:CP$(CP)2:2452:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CSIC:CP$(CP)2:2452:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CSIC:CP$(CP)2:2452:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CSIC:CP$(CP)2:2452:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CSIC:CP$(CP)2:2452:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CSIC:CP$(CP)2:2452:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CSIC:CP$(CP)2:2452:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CSIC:CP$(CP)2:2452:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CSIC:CP$(CP)2:2452:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CSIC:CP$(CP)2:2452:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452_OVH.Mode_String") } record(bi, "CSIC:CP$(CP)2:2452:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CSIC:CP$(CP)2:2452:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CSIC:CP$(CP)2:2452:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22452") } record(ai, "CSIC:CP$(CP)2:2452:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CSIC:CP$(CP)2:2452:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CSIC:CP$(CP)2:2452:ORBV",2100,2312,0,1,"CSIC:CP$(CP)2:2452:ORBV") #! Record("CSIC:CP$(CP)2:2452:OVAL",2280,2312,0,1,"CSIC:CP$(CP)2:2452:OVAL") #! Record("CSIC:CP$(CP)2:2452:CVAL",2460,2312,0,1,"CSIC:CP$(CP)2:2452:CVAL") #! Record("CSIC:CP$(CP)2:2452:MAX",2122,1932,0,1,"CSIC:CP$(CP)2:2452:MAX") #! Record("CSIC:CP$(CP)2:2452:DMIN",2300,1932,0,1,"CSIC:CP$(CP)2:2452:DMIN") #! Record("CSIC:CP$(CP)2:2452:DMAX",2479,1932,0,1,"CSIC:CP$(CP)2:2452:DMAX") #! Record("CSIC:CP$(CP)2:2452:MODE_RQST",1760,2112,0,1,"CSIC:CP$(CP)2:2452:MODE_RQST") #! Record("CSIC:CP$(CP)2:2452:MDT",2120,2112,0,1,"CSIC:CP$(CP)2:2452:MDT") #! Record("CSIC:CP$(CP)2:2452:KP",2300,2106,0,1,"CSIC:CP$(CP)2:2452:KP") #! Record("CSIC:CP$(CP)2:2452:KI",2480,2106,0,1,"CSIC:CP$(CP)2:2452:KI") #! Record("CSIC:CP$(CP)2:2452:KD",2660,2106,0,1,"CSIC:CP$(CP)2:2452:KD") #! Record("CSIC:CP$(CP)2:2452:S",2840,2120,0,1,"CSIC:CP$(CP)2:2452:S") #! Record("CSIC:CP$(CP)2:2452:SP_RQST",1760,1932,0,1,"CSIC:CP$(CP)2:2452:SP_RQST") #! Record("CSIC:CP$(CP)2:2452:MIN",1945,1932,0,1,"CSIC:CP$(CP)2:2452:MIN") #! Record("CSIC:CP$(CP)2:2452:PIDTAG",1740,2462,0,1,"CSIC:CP$(CP)2:2452:PIDTAG") #! Record("CSIC:CP$(CP)2:2452:PEVAL",2660,1932,0,1,"CSIC:CP$(CP)2:2452:PEVAL") #! Record("CSIC:CP$(CP)2:2452:FSB",2840,1932,0,1,"CSIC:CP$(CP)2:2452:FSB") #! Record("CSIC:CP$(CP)2:2452:NOMATCH",2640,2506,0,1,"CSIC:CP$(CP)2:2452:NOMATCH") #! Record("CSIC:CP$(CP)2:2452:CHFAULT",2820,2506,0,1,"CSIC:CP$(CP)2:2452:CHFAULT") #! Record("CSIC:CP$(CP)2:2452:MANPOS_RQST",1940,2112,0,1,"CSIC:CP$(CP)2:2452:MANPOS_RQST") #! Record("CSIC:CP$(CP)2:2452:MODE_STATUS",1740,2639,0,1,"CSIC:CP$(CP)2:2452:MODE_STATUS") #! Record("CSIC:CP$(CP)2:2452:INTERLOCKED",2460,2686,0,0,"CSIC:CP$(CP)2:2452:INTERLOCKED") #! Record("CSIC:CP$(CP)2:2452:INTERLOCK",2460,2506,0,0,"CSIC:CP$(CP)2:2452:INTERLOCK") #! Record("CSIC:CP$(CP)2:2452:IVAL",2641,2312,0,1,"CSIC:CP$(CP)2:2452:IVAL") #! Record("CSIC:CP$(CP)2:2452:SVAL",2820,2312,0,1,"CSIC:CP$(CP)2:2452:SVAL") #! Record("CSIC:CP$(CP)2:2452:MMOD",2102,2506,0,1,"CSIC:CP$(CP)2:2452:MMOD") #! Record("CSIC:CP$(CP)2:2452:SMOD",2282,2506,0,1,"CSIC:CP$(CP)2:2452:SMOD") #! Record("CSIC:CP$(CP)2:2452:MODE_STRING",1740,2314,0,1,"CSIC:CP$(CP)2:2452:MODE_STRING") #! Record("CSIC:CP$(CP)2:2452:PMOD",1922,2506,0,1,"CSIC:CP$(CP)2:2452:PMOD") #! Record("CSIC:CP$(CP)2:2452:IMOD",3020,2506,0,1,"CSIC:CP$(CP)2:2452:IMOD") #! Record("CSIC:CP$(CP)2:2452:ACTUATOR",1920,2322,0,1,"CSIC:CP$(CP)2:2452:ACTUATOR") #! Record("CSIC:CP$(CP)2:2452:PVAL",3000,2312,0,1,"CSIC:CP$(CP)2:2452:PVAL") #! Record("CSIC:CP$(CP)2:2452:CMD",3021,2112,0,1,"CSIC:CP$(CP)2:2452:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCSIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2452 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CTIC:CP$(CP)2:2452:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2452:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2452:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A.CVAL") field(PREC, "2") field(EGU, "K") field(ADEL, ".01") } record(ao, "CTIC:CP$(CP)2:2452:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2452:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2452:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2452:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2452:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2452:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2452:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2452:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CTIC:CP$(CP)2:2452:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2452:SP_RQST") { field(DESC, "C$(CP)TIC22352 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A_OVH.SP_Rqst") field(PREC, "2") field(EGU, "K") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2452:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CTIC:CP$(CP)2:2452:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)TIC22352") } record(ao, "CTIC:CP$(CP)2:2452:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2452:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CTIC:CP$(CP)2:2452:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CTIC:CP$(CP)2:2452:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CTIC:CP$(CP)2:2452:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CTIC:CP$(CP)2:2452:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2452:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2452:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CTIC:CP$(CP)2:2452:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CTIC:CP$(CP)2:2452:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CTIC:CP$(CP)2:2452:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CTIC:CP$(CP)2:2452:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CTIC:CP$(CP)2:2452:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A_OVH.Mode_String") } record(bi, "CTIC:CP$(CP)2:2452:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CTIC:CP$(CP)2:2452:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CTIC:CP$(CP)2:2452:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22452A") } record(ai, "CTIC:CP$(CP)2:2452:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22452A.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CTIC:CP$(CP)2:2452:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22452A.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CTIC:CP$(CP)2:2452:ORBV",2100,2312,0,1,"CTIC:CP$(CP)2:2452:ORBV") #! Record("CTIC:CP$(CP)2:2452:OVAL",2280,2312,0,1,"CTIC:CP$(CP)2:2452:OVAL") #! Record("CTIC:CP$(CP)2:2452:CVAL",2460,2312,0,1,"CTIC:CP$(CP)2:2452:CVAL") #! Record("CTIC:CP$(CP)2:2452:MAX",2122,1932,0,1,"CTIC:CP$(CP)2:2452:MAX") #! Record("CTIC:CP$(CP)2:2452:DMIN",2300,1932,0,1,"CTIC:CP$(CP)2:2452:DMIN") #! Record("CTIC:CP$(CP)2:2452:DMAX",2479,1932,0,1,"CTIC:CP$(CP)2:2452:DMAX") #! Record("CTIC:CP$(CP)2:2452:MODE_RQST",1760,2112,0,1,"CTIC:CP$(CP)2:2452:MODE_RQST") #! Record("CTIC:CP$(CP)2:2452:MDT",2120,2112,0,1,"CTIC:CP$(CP)2:2452:MDT") #! Record("CTIC:CP$(CP)2:2452:KP",2300,2106,0,1,"CTIC:CP$(CP)2:2452:KP") #! Record("CTIC:CP$(CP)2:2452:KI",2480,2106,0,1,"CTIC:CP$(CP)2:2452:KI") #! Record("CTIC:CP$(CP)2:2452:KD",2660,2106,0,1,"CTIC:CP$(CP)2:2452:KD") #! Record("CTIC:CP$(CP)2:2452:S",2840,2120,0,1,"CTIC:CP$(CP)2:2452:S") #! Record("CTIC:CP$(CP)2:2452:SP_RQST",1760,1932,0,1,"CTIC:CP$(CP)2:2452:SP_RQST") #! Record("CTIC:CP$(CP)2:2452:MIN",1945,1932,0,1,"CTIC:CP$(CP)2:2452:MIN") #! Record("CTIC:CP$(CP)2:2452:PIDTAG",1740,2462,0,1,"CTIC:CP$(CP)2:2452:PIDTAG") #! Record("CTIC:CP$(CP)2:2452:PEVAL",2660,1932,0,1,"CTIC:CP$(CP)2:2452:PEVAL") #! Record("CTIC:CP$(CP)2:2452:FSB",2840,1932,0,1,"CTIC:CP$(CP)2:2452:FSB") #! Record("CTIC:CP$(CP)2:2452:NOMATCH",2640,2506,0,1,"CTIC:CP$(CP)2:2452:NOMATCH") #! Record("CTIC:CP$(CP)2:2452:CHFAULT",2820,2506,0,1,"CTIC:CP$(CP)2:2452:CHFAULT") #! Record("CTIC:CP$(CP)2:2452:MANPOS_RQST",1940,2112,0,1,"CTIC:CP$(CP)2:2452:MANPOS_RQST") #! Record("CTIC:CP$(CP)2:2452:MODE_STATUS",1740,2639,0,1,"CTIC:CP$(CP)2:2452:MODE_STATUS") #! Record("CTIC:CP$(CP)2:2452:INTERLOCKED",2460,2686,0,0,"CTIC:CP$(CP)2:2452:INTERLOCKED") #! Record("CTIC:CP$(CP)2:2452:INTERLOCK",2460,2506,0,0,"CTIC:CP$(CP)2:2452:INTERLOCK") #! Record("CTIC:CP$(CP)2:2452:IVAL",2641,2312,0,1,"CTIC:CP$(CP)2:2452:IVAL") #! Record("CTIC:CP$(CP)2:2452:SVAL",2820,2312,0,1,"CTIC:CP$(CP)2:2452:SVAL") #! Record("CTIC:CP$(CP)2:2452:MMOD",2102,2506,0,1,"CTIC:CP$(CP)2:2452:MMOD") #! Record("CTIC:CP$(CP)2:2452:SMOD",2282,2506,0,1,"CTIC:CP$(CP)2:2452:SMOD") #! Record("CTIC:CP$(CP)2:2452:MODE_STRING",1740,2314,0,1,"CTIC:CP$(CP)2:2452:MODE_STRING") #! Record("CTIC:CP$(CP)2:2452:PMOD",1922,2506,0,1,"CTIC:CP$(CP)2:2452:PMOD") #! Record("CTIC:CP$(CP)2:2452:IMOD",3020,2506,0,1,"CTIC:CP$(CP)2:2452:IMOD") #! Record("CTIC:CP$(CP)2:2452:ACTUATOR",1920,2322,0,1,"CTIC:CP$(CP)2:2452:ACTUATOR") #! Record("CTIC:CP$(CP)2:2452:PVAL",3000,2312,0,1,"CTIC:CP$(CP)2:2452:PVAL") #! Record("CTIC:CP$(CP)2:2452:CMD",3021,2112,0,1,"CTIC:CP$(CP)2:2452:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCTIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2452 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CSIC:CP$(CP)2:2472:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CSIC:CP$(CP)2:2472:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CSIC:CP$(CP)2:2472:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472.CVAL") field(PREC, "2") field(EGU, "Hz") field(ADEL, ".01") } record(ao, "CSIC:CP$(CP)2:2472:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2472:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2472:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CSIC:CP$(CP)2:2472:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2472:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2472:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2472:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2472:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CSIC:CP$(CP)2:2472:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2472:SP_RQST") { field(DESC, "C$(CP)SIC22472 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472_OVH.SP_Rqst") field(PREC, "2") field(EGU, "Hz") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2472:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CSIC:CP$(CP)2:2472:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)SIC22472") } record(ao, "CSIC:CP$(CP)2:2472:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CSIC:CP$(CP)2:2472:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CSIC:CP$(CP)2:2472:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CSIC:CP$(CP)2:2472:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CSIC:CP$(CP)2:2472:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CSIC:CP$(CP)2:2472:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CSIC:CP$(CP)2:2472:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CSIC:CP$(CP)2:2472:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CSIC:CP$(CP)2:2472:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CSIC:CP$(CP)2:2472:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CSIC:CP$(CP)2:2472:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CSIC:CP$(CP)2:2472:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CSIC:CP$(CP)2:2472:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472_OVH.Mode_String") } record(bi, "CSIC:CP$(CP)2:2472:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CSIC:CP$(CP)2:2472:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CSIC:CP$(CP)2:2472:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22472") } record(ai, "CSIC:CP$(CP)2:2472:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CSIC:CP$(CP)2:2472:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CSIC:CP$(CP)2:2472:ORBV",2100,2312,0,1,"CSIC:CP$(CP)2:2472:ORBV") #! Record("CSIC:CP$(CP)2:2472:OVAL",2280,2312,0,1,"CSIC:CP$(CP)2:2472:OVAL") #! Record("CSIC:CP$(CP)2:2472:CVAL",2460,2312,0,1,"CSIC:CP$(CP)2:2472:CVAL") #! Record("CSIC:CP$(CP)2:2472:MAX",2122,1932,0,1,"CSIC:CP$(CP)2:2472:MAX") #! Record("CSIC:CP$(CP)2:2472:DMIN",2300,1932,0,1,"CSIC:CP$(CP)2:2472:DMIN") #! Record("CSIC:CP$(CP)2:2472:DMAX",2479,1932,0,1,"CSIC:CP$(CP)2:2472:DMAX") #! Record("CSIC:CP$(CP)2:2472:MODE_RQST",1760,2112,0,1,"CSIC:CP$(CP)2:2472:MODE_RQST") #! Record("CSIC:CP$(CP)2:2472:MDT",2120,2112,0,1,"CSIC:CP$(CP)2:2472:MDT") #! Record("CSIC:CP$(CP)2:2472:KP",2300,2106,0,1,"CSIC:CP$(CP)2:2472:KP") #! Record("CSIC:CP$(CP)2:2472:KI",2480,2106,0,1,"CSIC:CP$(CP)2:2472:KI") #! Record("CSIC:CP$(CP)2:2472:KD",2660,2106,0,1,"CSIC:CP$(CP)2:2472:KD") #! Record("CSIC:CP$(CP)2:2472:S",2840,2120,0,1,"CSIC:CP$(CP)2:2472:S") #! Record("CSIC:CP$(CP)2:2472:SP_RQST",1760,1932,0,1,"CSIC:CP$(CP)2:2472:SP_RQST") #! Record("CSIC:CP$(CP)2:2472:MIN",1945,1932,0,1,"CSIC:CP$(CP)2:2472:MIN") #! Record("CSIC:CP$(CP)2:2472:PIDTAG",1740,2462,0,1,"CSIC:CP$(CP)2:2472:PIDTAG") #! Record("CSIC:CP$(CP)2:2472:PEVAL",2660,1932,0,1,"CSIC:CP$(CP)2:2472:PEVAL") #! Record("CSIC:CP$(CP)2:2472:FSB",2840,1932,0,1,"CSIC:CP$(CP)2:2472:FSB") #! Record("CSIC:CP$(CP)2:2472:NOMATCH",2640,2506,0,1,"CSIC:CP$(CP)2:2472:NOMATCH") #! Record("CSIC:CP$(CP)2:2472:CHFAULT",2820,2506,0,1,"CSIC:CP$(CP)2:2472:CHFAULT") #! Record("CSIC:CP$(CP)2:2472:MANPOS_RQST",1940,2112,0,1,"CSIC:CP$(CP)2:2472:MANPOS_RQST") #! Record("CSIC:CP$(CP)2:2472:MODE_STATUS",1740,2639,0,1,"CSIC:CP$(CP)2:2472:MODE_STATUS") #! Record("CSIC:CP$(CP)2:2472:INTERLOCKED",2460,2686,0,0,"CSIC:CP$(CP)2:2472:INTERLOCKED") #! Record("CSIC:CP$(CP)2:2472:INTERLOCK",2460,2506,0,0,"CSIC:CP$(CP)2:2472:INTERLOCK") #! Record("CSIC:CP$(CP)2:2472:IVAL",2641,2312,0,1,"CSIC:CP$(CP)2:2472:IVAL") #! Record("CSIC:CP$(CP)2:2472:SVAL",2820,2312,0,1,"CSIC:CP$(CP)2:2472:SVAL") #! Record("CSIC:CP$(CP)2:2472:MMOD",2102,2506,0,1,"CSIC:CP$(CP)2:2472:MMOD") #! Record("CSIC:CP$(CP)2:2472:SMOD",2282,2506,0,1,"CSIC:CP$(CP)2:2472:SMOD") #! Record("CSIC:CP$(CP)2:2472:MODE_STRING",1740,2314,0,1,"CSIC:CP$(CP)2:2472:MODE_STRING") #! Record("CSIC:CP$(CP)2:2472:PMOD",1922,2506,0,1,"CSIC:CP$(CP)2:2472:PMOD") #! Record("CSIC:CP$(CP)2:2472:IMOD",3020,2506,0,1,"CSIC:CP$(CP)2:2472:IMOD") #! Record("CSIC:CP$(CP)2:2472:ACTUATOR",1920,2322,0,1,"CSIC:CP$(CP)2:2472:ACTUATOR") #! Record("CSIC:CP$(CP)2:2472:PVAL",3000,2312,0,1,"CSIC:CP$(CP)2:2472:PVAL") #! Record("CSIC:CP$(CP)2:2472:CMD",3021,2112,0,1,"CSIC:CP$(CP)2:2472:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCSIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2472 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CTIC:CP$(CP)2:2472:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2472:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2472:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A.CVAL") field(PREC, "2") field(EGU, "K") field(ADEL, ".01") } record(ao, "CTIC:CP$(CP)2:2472:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2472:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2472:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2472:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2472:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2472:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2472:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2472:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CTIC:CP$(CP)2:2472:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2472:SP_RQST") { field(DESC, "C$(CP)TIC22372 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A_OVH.SP_Rqst") field(PREC, "2") field(EGU, "K") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2472:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CTIC:CP$(CP)2:2472:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)TIC22372") } record(ao, "CTIC:CP$(CP)2:2472:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2472:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CTIC:CP$(CP)2:2472:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CTIC:CP$(CP)2:2472:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CTIC:CP$(CP)2:2472:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CTIC:CP$(CP)2:2472:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2472:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2472:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CTIC:CP$(CP)2:2472:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CTIC:CP$(CP)2:2472:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CTIC:CP$(CP)2:2472:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CTIC:CP$(CP)2:2472:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CTIC:CP$(CP)2:2472:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A_OVH.Mode_String") } record(bi, "CTIC:CP$(CP)2:2472:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CTIC:CP$(CP)2:2472:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CTIC:CP$(CP)2:2472:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22472A") } record(ai, "CTIC:CP$(CP)2:2472:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22472A.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CTIC:CP$(CP)2:2472:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22472A.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CTIC:CP$(CP)2:2472:ORBV",2100,2312,0,1,"CTIC:CP$(CP)2:2472:ORBV") #! Record("CTIC:CP$(CP)2:2472:OVAL",2280,2312,0,1,"CTIC:CP$(CP)2:2472:OVAL") #! Record("CTIC:CP$(CP)2:2472:CVAL",2460,2312,0,1,"CTIC:CP$(CP)2:2472:CVAL") #! Record("CTIC:CP$(CP)2:2472:MAX",2122,1932,0,1,"CTIC:CP$(CP)2:2472:MAX") #! Record("CTIC:CP$(CP)2:2472:DMIN",2300,1932,0,1,"CTIC:CP$(CP)2:2472:DMIN") #! Record("CTIC:CP$(CP)2:2472:DMAX",2479,1932,0,1,"CTIC:CP$(CP)2:2472:DMAX") #! Record("CTIC:CP$(CP)2:2472:MODE_RQST",1760,2112,0,1,"CTIC:CP$(CP)2:2472:MODE_RQST") #! Record("CTIC:CP$(CP)2:2472:MDT",2120,2112,0,1,"CTIC:CP$(CP)2:2472:MDT") #! Record("CTIC:CP$(CP)2:2472:KP",2300,2106,0,1,"CTIC:CP$(CP)2:2472:KP") #! Record("CTIC:CP$(CP)2:2472:KI",2480,2106,0,1,"CTIC:CP$(CP)2:2472:KI") #! Record("CTIC:CP$(CP)2:2472:KD",2660,2106,0,1,"CTIC:CP$(CP)2:2472:KD") #! Record("CTIC:CP$(CP)2:2472:S",2840,2120,0,1,"CTIC:CP$(CP)2:2472:S") #! Record("CTIC:CP$(CP)2:2472:SP_RQST",1760,1932,0,1,"CTIC:CP$(CP)2:2472:SP_RQST") #! Record("CTIC:CP$(CP)2:2472:MIN",1945,1932,0,1,"CTIC:CP$(CP)2:2472:MIN") #! Record("CTIC:CP$(CP)2:2472:PIDTAG",1740,2462,0,1,"CTIC:CP$(CP)2:2472:PIDTAG") #! Record("CTIC:CP$(CP)2:2472:PEVAL",2660,1932,0,1,"CTIC:CP$(CP)2:2472:PEVAL") #! Record("CTIC:CP$(CP)2:2472:FSB",2840,1932,0,1,"CTIC:CP$(CP)2:2472:FSB") #! Record("CTIC:CP$(CP)2:2472:NOMATCH",2640,2506,0,1,"CTIC:CP$(CP)2:2472:NOMATCH") #! Record("CTIC:CP$(CP)2:2472:CHFAULT",2820,2506,0,1,"CTIC:CP$(CP)2:2472:CHFAULT") #! Record("CTIC:CP$(CP)2:2472:MANPOS_RQST",1940,2112,0,1,"CTIC:CP$(CP)2:2472:MANPOS_RQST") #! Record("CTIC:CP$(CP)2:2472:MODE_STATUS",1740,2639,0,1,"CTIC:CP$(CP)2:2472:MODE_STATUS") #! Record("CTIC:CP$(CP)2:2472:INTERLOCKED",2460,2686,0,0,"CTIC:CP$(CP)2:2472:INTERLOCKED") #! Record("CTIC:CP$(CP)2:2472:INTERLOCK",2460,2506,0,0,"CTIC:CP$(CP)2:2472:INTERLOCK") #! Record("CTIC:CP$(CP)2:2472:IVAL",2641,2312,0,1,"CTIC:CP$(CP)2:2472:IVAL") #! Record("CTIC:CP$(CP)2:2472:SVAL",2820,2312,0,1,"CTIC:CP$(CP)2:2472:SVAL") #! Record("CTIC:CP$(CP)2:2472:MMOD",2102,2506,0,1,"CTIC:CP$(CP)2:2472:MMOD") #! Record("CTIC:CP$(CP)2:2472:SMOD",2282,2506,0,1,"CTIC:CP$(CP)2:2472:SMOD") #! Record("CTIC:CP$(CP)2:2472:MODE_STRING",1740,2314,0,1,"CTIC:CP$(CP)2:2472:MODE_STRING") #! Record("CTIC:CP$(CP)2:2472:PMOD",1922,2506,0,1,"CTIC:CP$(CP)2:2472:PMOD") #! Record("CTIC:CP$(CP)2:2472:IMOD",3020,2506,0,1,"CTIC:CP$(CP)2:2472:IMOD") #! Record("CTIC:CP$(CP)2:2472:ACTUATOR",1920,2322,0,1,"CTIC:CP$(CP)2:2472:ACTUATOR") #! Record("CTIC:CP$(CP)2:2472:PVAL",3000,2312,0,1,"CTIC:CP$(CP)2:2472:PVAL") #! Record("CTIC:CP$(CP)2:2472:CMD",3021,2112,0,1,"CTIC:CP$(CP)2:2472:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCTIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2472 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CSIC:CP$(CP)2:2482:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CSIC:CP$(CP)2:2482:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CSIC:CP$(CP)2:2482:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482.CVAL") field(PREC, "2") field(EGU, "Hz") field(ADEL, ".01") } record(ao, "CSIC:CP$(CP)2:2482:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2482:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2482:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CSIC:CP$(CP)2:2482:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2482:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2482:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2482:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2482:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CSIC:CP$(CP)2:2482:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2482:SP_RQST") { field(DESC, "C$(CP)SIC22482 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482_OVH.SP_Rqst") field(PREC, "2") field(EGU, "Hz") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CSIC:CP$(CP)2:2482:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CSIC:CP$(CP)2:2482:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)SIC22482") } record(ao, "CSIC:CP$(CP)2:2482:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CSIC:CP$(CP)2:2482:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CSIC:CP$(CP)2:2482:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CSIC:CP$(CP)2:2482:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CSIC:CP$(CP)2:2482:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CSIC:CP$(CP)2:2482:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CSIC:CP$(CP)2:2482:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CSIC:CP$(CP)2:2482:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CSIC:CP$(CP)2:2482:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CSIC:CP$(CP)2:2482:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CSIC:CP$(CP)2:2482:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CSIC:CP$(CP)2:2482:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CSIC:CP$(CP)2:2482:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482_OVH.Mode_String") } record(bi, "CSIC:CP$(CP)2:2482:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CSIC:CP$(CP)2:2482:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CSIC:CP$(CP)2:2482:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22482") } record(ai, "CSIC:CP$(CP)2:2482:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CSIC:CP$(CP)2:2482:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CSIC:CP$(CP)2:2482:ORBV",2100,2312,0,1,"CSIC:CP$(CP)2:2482:ORBV") #! Record("CSIC:CP$(CP)2:2482:OVAL",2280,2312,0,1,"CSIC:CP$(CP)2:2482:OVAL") #! Record("CSIC:CP$(CP)2:2482:CVAL",2460,2312,0,1,"CSIC:CP$(CP)2:2482:CVAL") #! Record("CSIC:CP$(CP)2:2482:MAX",2122,1932,0,1,"CSIC:CP$(CP)2:2482:MAX") #! Record("CSIC:CP$(CP)2:2482:DMIN",2300,1932,0,1,"CSIC:CP$(CP)2:2482:DMIN") #! Record("CSIC:CP$(CP)2:2482:DMAX",2479,1932,0,1,"CSIC:CP$(CP)2:2482:DMAX") #! Record("CSIC:CP$(CP)2:2482:MODE_RQST",1760,2112,0,1,"CSIC:CP$(CP)2:2482:MODE_RQST") #! Record("CSIC:CP$(CP)2:2482:MDT",2120,2112,0,1,"CSIC:CP$(CP)2:2482:MDT") #! Record("CSIC:CP$(CP)2:2482:KP",2300,2106,0,1,"CSIC:CP$(CP)2:2482:KP") #! Record("CSIC:CP$(CP)2:2482:KI",2480,2106,0,1,"CSIC:CP$(CP)2:2482:KI") #! Record("CSIC:CP$(CP)2:2482:KD",2660,2106,0,1,"CSIC:CP$(CP)2:2482:KD") #! Record("CSIC:CP$(CP)2:2482:S",2840,2120,0,1,"CSIC:CP$(CP)2:2482:S") #! Record("CSIC:CP$(CP)2:2482:SP_RQST",1760,1932,0,1,"CSIC:CP$(CP)2:2482:SP_RQST") #! Record("CSIC:CP$(CP)2:2482:MIN",1945,1932,0,1,"CSIC:CP$(CP)2:2482:MIN") #! Record("CSIC:CP$(CP)2:2482:PIDTAG",1740,2462,0,1,"CSIC:CP$(CP)2:2482:PIDTAG") #! Record("CSIC:CP$(CP)2:2482:PEVAL",2660,1932,0,1,"CSIC:CP$(CP)2:2482:PEVAL") #! Record("CSIC:CP$(CP)2:2482:FSB",2840,1932,0,1,"CSIC:CP$(CP)2:2482:FSB") #! Record("CSIC:CP$(CP)2:2482:NOMATCH",2640,2506,0,1,"CSIC:CP$(CP)2:2482:NOMATCH") #! Record("CSIC:CP$(CP)2:2482:CHFAULT",2820,2506,0,1,"CSIC:CP$(CP)2:2482:CHFAULT") #! Record("CSIC:CP$(CP)2:2482:MANPOS_RQST",1940,2112,0,1,"CSIC:CP$(CP)2:2482:MANPOS_RQST") #! Record("CSIC:CP$(CP)2:2482:MODE_STATUS",1740,2639,0,1,"CSIC:CP$(CP)2:2482:MODE_STATUS") #! Record("CSIC:CP$(CP)2:2482:INTERLOCKED",2460,2686,0,0,"CSIC:CP$(CP)2:2482:INTERLOCKED") #! Record("CSIC:CP$(CP)2:2482:INTERLOCK",2460,2506,0,0,"CSIC:CP$(CP)2:2482:INTERLOCK") #! Record("CSIC:CP$(CP)2:2482:IVAL",2641,2312,0,1,"CSIC:CP$(CP)2:2482:IVAL") #! Record("CSIC:CP$(CP)2:2482:SVAL",2820,2312,0,1,"CSIC:CP$(CP)2:2482:SVAL") #! Record("CSIC:CP$(CP)2:2482:MMOD",2102,2506,0,1,"CSIC:CP$(CP)2:2482:MMOD") #! Record("CSIC:CP$(CP)2:2482:SMOD",2282,2506,0,1,"CSIC:CP$(CP)2:2482:SMOD") #! Record("CSIC:CP$(CP)2:2482:MODE_STRING",1740,2314,0,1,"CSIC:CP$(CP)2:2482:MODE_STRING") #! Record("CSIC:CP$(CP)2:2482:PMOD",1922,2506,0,1,"CSIC:CP$(CP)2:2482:PMOD") #! Record("CSIC:CP$(CP)2:2482:IMOD",3020,2506,0,1,"CSIC:CP$(CP)2:2482:IMOD") #! Record("CSIC:CP$(CP)2:2482:ACTUATOR",1920,2322,0,1,"CSIC:CP$(CP)2:2482:ACTUATOR") #! Record("CSIC:CP$(CP)2:2482:PVAL",3000,2312,0,1,"CSIC:CP$(CP)2:2482:PVAL") #! Record("CSIC:CP$(CP)2:2482:CMD",3021,2112,0,1,"CSIC:CP$(CP)2:2482:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCSIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2482 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CTIC:CP$(CP)2:2466:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2466:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2466:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A.CVAL") field(PREC, "2") field(EGU, "K") field(ADEL, ".01") } record(ao, "CTIC:CP$(CP)2:2466:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2466:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2466:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2466:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2466:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2466:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2466:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2466:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CTIC:CP$(CP)2:2466:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2466:SP_RQST") { field(DESC, "C$(CP)TIC22466 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A_OVH.SP_Rqst") field(PREC, "2") field(EGU, "K") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2466:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CTIC:CP$(CP)2:2466:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)TIC22466") } record(ao, "CTIC:CP$(CP)2:2466:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2466:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CTIC:CP$(CP)2:2466:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CTIC:CP$(CP)2:2466:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CTIC:CP$(CP)2:2466:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CTIC:CP$(CP)2:2466:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2466:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2466:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CTIC:CP$(CP)2:2466:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CTIC:CP$(CP)2:2466:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CTIC:CP$(CP)2:2466:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CTIC:CP$(CP)2:2466:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CTIC:CP$(CP)2:2466:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A_OVH.Mode_String") } record(bi, "CTIC:CP$(CP)2:2466:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CTIC:CP$(CP)2:2466:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CTIC:CP$(CP)2:2466:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22482A") } record(ai, "CTIC:CP$(CP)2:2466:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22482A.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CTIC:CP$(CP)2:2466:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22482A.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CTIC:CP$(CP)2:2466:ORBV",2100,2312,0,1,"CTIC:CP$(CP)2:2466:ORBV") #! Record("CTIC:CP$(CP)2:2466:OVAL",2280,2312,0,1,"CTIC:CP$(CP)2:2466:OVAL") #! Record("CTIC:CP$(CP)2:2466:CVAL",2460,2312,0,1,"CTIC:CP$(CP)2:2466:CVAL") #! Record("CTIC:CP$(CP)2:2466:MAX",2122,1932,0,1,"CTIC:CP$(CP)2:2466:MAX") #! Record("CTIC:CP$(CP)2:2466:DMIN",2300,1932,0,1,"CTIC:CP$(CP)2:2466:DMIN") #! Record("CTIC:CP$(CP)2:2466:DMAX",2479,1932,0,1,"CTIC:CP$(CP)2:2466:DMAX") #! Record("CTIC:CP$(CP)2:2466:MODE_RQST",1760,2112,0,1,"CTIC:CP$(CP)2:2466:MODE_RQST") #! Record("CTIC:CP$(CP)2:2466:MDT",2120,2112,0,1,"CTIC:CP$(CP)2:2466:MDT") #! Record("CTIC:CP$(CP)2:2466:KP",2300,2106,0,1,"CTIC:CP$(CP)2:2466:KP") #! Record("CTIC:CP$(CP)2:2466:KI",2480,2106,0,1,"CTIC:CP$(CP)2:2466:KI") #! Record("CTIC:CP$(CP)2:2466:KD",2660,2106,0,1,"CTIC:CP$(CP)2:2466:KD") #! Record("CTIC:CP$(CP)2:2466:S",2840,2120,0,1,"CTIC:CP$(CP)2:2466:S") #! Record("CTIC:CP$(CP)2:2466:SP_RQST",1760,1932,0,1,"CTIC:CP$(CP)2:2466:SP_RQST") #! Record("CTIC:CP$(CP)2:2466:MIN",1945,1932,0,1,"CTIC:CP$(CP)2:2466:MIN") #! Record("CTIC:CP$(CP)2:2466:PIDTAG",1740,2462,0,1,"CTIC:CP$(CP)2:2466:PIDTAG") #! Record("CTIC:CP$(CP)2:2466:PEVAL",2660,1932,0,1,"CTIC:CP$(CP)2:2466:PEVAL") #! Record("CTIC:CP$(CP)2:2466:FSB",2840,1932,0,1,"CTIC:CP$(CP)2:2466:FSB") #! Record("CTIC:CP$(CP)2:2466:NOMATCH",2640,2506,0,1,"CTIC:CP$(CP)2:2466:NOMATCH") #! Record("CTIC:CP$(CP)2:2466:CHFAULT",2820,2506,0,1,"CTIC:CP$(CP)2:2466:CHFAULT") #! Record("CTIC:CP$(CP)2:2466:MANPOS_RQST",1940,2112,0,1,"CTIC:CP$(CP)2:2466:MANPOS_RQST") #! Record("CTIC:CP$(CP)2:2466:MODE_STATUS",1740,2639,0,1,"CTIC:CP$(CP)2:2466:MODE_STATUS") #! Record("CTIC:CP$(CP)2:2466:INTERLOCKED",2460,2686,0,0,"CTIC:CP$(CP)2:2466:INTERLOCKED") #! Record("CTIC:CP$(CP)2:2466:INTERLOCK",2460,2506,0,0,"CTIC:CP$(CP)2:2466:INTERLOCK") #! Record("CTIC:CP$(CP)2:2466:IVAL",2641,2312,0,1,"CTIC:CP$(CP)2:2466:IVAL") #! Record("CTIC:CP$(CP)2:2466:SVAL",2820,2312,0,1,"CTIC:CP$(CP)2:2466:SVAL") #! Record("CTIC:CP$(CP)2:2466:MMOD",2102,2506,0,1,"CTIC:CP$(CP)2:2466:MMOD") #! Record("CTIC:CP$(CP)2:2466:SMOD",2282,2506,0,1,"CTIC:CP$(CP)2:2466:SMOD") #! Record("CTIC:CP$(CP)2:2466:MODE_STRING",1740,2314,0,1,"CTIC:CP$(CP)2:2466:MODE_STRING") #! Record("CTIC:CP$(CP)2:2466:PMOD",1922,2506,0,1,"CTIC:CP$(CP)2:2466:PMOD") #! Record("CTIC:CP$(CP)2:2466:IMOD",3020,2506,0,1,"CTIC:CP$(CP)2:2466:IMOD") #! Record("CTIC:CP$(CP)2:2466:ACTUATOR",1920,2322,0,1,"CTIC:CP$(CP)2:2466:ACTUATOR") #! Record("CTIC:CP$(CP)2:2466:PVAL",3000,2312,0,1,"CTIC:CP$(CP)2:2466:PVAL") #! Record("CTIC:CP$(CP)2:2466:CMD",3021,2112,0,1,"CTIC:CP$(CP)2:2466:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCTIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2466 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)2:2436:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2436:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2436:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)2:2436:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2436:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2436:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2436:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2436:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2436:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2436:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2436:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)2:2436:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2436:SP_RQST") { field(DESC, "C$(CP)PIC22436 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2436:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)2:2436:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC22436") } record(ao, "CPIC:CP$(CP)2:2436:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2436:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)2:2436:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)2:2436:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)2:2436:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)2:2436:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2436:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2436:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)2:2436:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)2:2436:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)2:2436:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)2:2436:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)2:2436:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)2:2436:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)2:2436:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)2:2436:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "EV22436") } record(ai, "CPIC:CP$(CP)2:2436:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)2:2436:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)2:2436:ORBV",2100,2312,0,1,"CPIC:CP$(CP)2:2436:ORBV") #! Record("CPIC:CP$(CP)2:2436:OVAL",2280,2312,0,1,"CPIC:CP$(CP)2:2436:OVAL") #! Record("CPIC:CP$(CP)2:2436:CVAL",2460,2312,0,1,"CPIC:CP$(CP)2:2436:CVAL") #! Record("CPIC:CP$(CP)2:2436:MAX",2122,1932,0,1,"CPIC:CP$(CP)2:2436:MAX") #! Record("CPIC:CP$(CP)2:2436:DMIN",2300,1932,0,1,"CPIC:CP$(CP)2:2436:DMIN") #! Record("CPIC:CP$(CP)2:2436:DMAX",2479,1932,0,1,"CPIC:CP$(CP)2:2436:DMAX") #! Record("CPIC:CP$(CP)2:2436:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)2:2436:MODE_RQST") #! Record("CPIC:CP$(CP)2:2436:MDT",2120,2112,0,1,"CPIC:CP$(CP)2:2436:MDT") #! Record("CPIC:CP$(CP)2:2436:KP",2300,2106,0,1,"CPIC:CP$(CP)2:2436:KP") #! Record("CPIC:CP$(CP)2:2436:KI",2480,2106,0,1,"CPIC:CP$(CP)2:2436:KI") #! Record("CPIC:CP$(CP)2:2436:KD",2660,2106,0,1,"CPIC:CP$(CP)2:2436:KD") #! Record("CPIC:CP$(CP)2:2436:S",2840,2120,0,1,"CPIC:CP$(CP)2:2436:S") #! Record("CPIC:CP$(CP)2:2436:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)2:2436:SP_RQST") #! Record("CPIC:CP$(CP)2:2436:MIN",1945,1932,0,1,"CPIC:CP$(CP)2:2436:MIN") #! Record("CPIC:CP$(CP)2:2436:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)2:2436:PIDTAG") #! Record("CPIC:CP$(CP)2:2436:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)2:2436:PEVAL") #! Record("CPIC:CP$(CP)2:2436:FSB",2840,1932,0,1,"CPIC:CP$(CP)2:2436:FSB") #! Record("CPIC:CP$(CP)2:2436:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)2:2436:NOMATCH") #! Record("CPIC:CP$(CP)2:2436:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)2:2436:CHFAULT") #! Record("CPIC:CP$(CP)2:2436:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)2:2436:MANPOS_RQST") #! Record("CPIC:CP$(CP)2:2436:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)2:2436:MODE_STATUS") #! Record("CPIC:CP$(CP)2:2436:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)2:2436:INTERLOCKED") #! Record("CPIC:CP$(CP)2:2436:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)2:2436:INTERLOCK") #! Record("CPIC:CP$(CP)2:2436:IVAL",2641,2312,0,1,"CPIC:CP$(CP)2:2436:IVAL") #! Record("CPIC:CP$(CP)2:2436:SVAL",2820,2312,0,1,"CPIC:CP$(CP)2:2436:SVAL") #! Record("CPIC:CP$(CP)2:2436:MMOD",2102,2506,0,1,"CPIC:CP$(CP)2:2436:MMOD") #! Record("CPIC:CP$(CP)2:2436:SMOD",2282,2506,0,1,"CPIC:CP$(CP)2:2436:SMOD") #! Record("CPIC:CP$(CP)2:2436:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)2:2436:MODE_STRING") #! Record("CPIC:CP$(CP)2:2436:PMOD",1922,2506,0,1,"CPIC:CP$(CP)2:2436:PMOD") #! Record("CPIC:CP$(CP)2:2436:IMOD",3020,2506,0,1,"CPIC:CP$(CP)2:2436:IMOD") #! Record("CPIC:CP$(CP)2:2436:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)2:2436:ACTUATOR") #! Record("CPIC:CP$(CP)2:2436:PVAL",3000,2312,0,1,"CPIC:CP$(CP)2:2436:PVAL") #! Record("CPIC:CP$(CP)2:2436:CMD",3021,2112,0,1,"CPIC:CP$(CP)2:2436:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2436 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CEIC:CP$(CP)2:2436:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CEIC:CP$(CP)2:2436:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CEIC:CP$(CP)2:2436:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A.CVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ao, "CEIC:CP$(CP)2:2436:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2436:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2436:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CEIC:CP$(CP)2:2436:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2436:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2436:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2436:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2436:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CEIC:CP$(CP)2:2436:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2436:SP_RQST") { field(DESC, "C$(CP)EIC22436 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A_OVH.SP_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2436:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CEIC:CP$(CP)2:2436:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)EIC22436") } record(ao, "CEIC:CP$(CP)2:2436:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CEIC:CP$(CP)2:2436:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CEIC:CP$(CP)2:2436:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CEIC:CP$(CP)2:2436:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CEIC:CP$(CP)2:2436:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CEIC:CP$(CP)2:2436:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CEIC:CP$(CP)2:2436:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CEIC:CP$(CP)2:2436:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CEIC:CP$(CP)2:2436:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CEIC:CP$(CP)2:2436:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CEIC:CP$(CP)2:2436:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CEIC:CP$(CP)2:2436:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CEIC:CP$(CP)2:2436:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A_OVH.Mode_String") } record(bi, "CEIC:CP$(CP)2:2436:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CEIC:CP$(CP)2:2436:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CEIC:CP$(CP)2:2436:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "EV22436A") } record(ai, "CEIC:CP$(CP)2:2436:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22436A.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CEIC:CP$(CP)2:2436:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22436A.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CEIC:CP$(CP)2:2436:ORBV",2100,2312,0,1,"CEIC:CP$(CP)2:2436:ORBV") #! Record("CEIC:CP$(CP)2:2436:OVAL",2280,2312,0,1,"CEIC:CP$(CP)2:2436:OVAL") #! Record("CEIC:CP$(CP)2:2436:CVAL",2460,2312,0,1,"CEIC:CP$(CP)2:2436:CVAL") #! Record("CEIC:CP$(CP)2:2436:MAX",2122,1932,0,1,"CEIC:CP$(CP)2:2436:MAX") #! Record("CEIC:CP$(CP)2:2436:DMIN",2300,1932,0,1,"CEIC:CP$(CP)2:2436:DMIN") #! Record("CEIC:CP$(CP)2:2436:DMAX",2479,1932,0,1,"CEIC:CP$(CP)2:2436:DMAX") #! Record("CEIC:CP$(CP)2:2436:MODE_RQST",1760,2112,0,1,"CEIC:CP$(CP)2:2436:MODE_RQST") #! Record("CEIC:CP$(CP)2:2436:MDT",2120,2112,0,1,"CEIC:CP$(CP)2:2436:MDT") #! Record("CEIC:CP$(CP)2:2436:KP",2300,2106,0,1,"CEIC:CP$(CP)2:2436:KP") #! Record("CEIC:CP$(CP)2:2436:KI",2480,2106,0,1,"CEIC:CP$(CP)2:2436:KI") #! Record("CEIC:CP$(CP)2:2436:KD",2660,2106,0,1,"CEIC:CP$(CP)2:2436:KD") #! Record("CEIC:CP$(CP)2:2436:S",2840,2120,0,1,"CEIC:CP$(CP)2:2436:S") #! Record("CEIC:CP$(CP)2:2436:SP_RQST",1760,1932,0,1,"CEIC:CP$(CP)2:2436:SP_RQST") #! Record("CEIC:CP$(CP)2:2436:MIN",1945,1932,0,1,"CEIC:CP$(CP)2:2436:MIN") #! Record("CEIC:CP$(CP)2:2436:PIDTAG",1740,2462,0,1,"CEIC:CP$(CP)2:2436:PIDTAG") #! Record("CEIC:CP$(CP)2:2436:PEVAL",2660,1932,0,1,"CEIC:CP$(CP)2:2436:PEVAL") #! Record("CEIC:CP$(CP)2:2436:FSB",2840,1932,0,1,"CEIC:CP$(CP)2:2436:FSB") #! Record("CEIC:CP$(CP)2:2436:NOMATCH",2640,2506,0,1,"CEIC:CP$(CP)2:2436:NOMATCH") #! Record("CEIC:CP$(CP)2:2436:CHFAULT",2820,2506,0,1,"CEIC:CP$(CP)2:2436:CHFAULT") #! Record("CEIC:CP$(CP)2:2436:MANPOS_RQST",1940,2112,0,1,"CEIC:CP$(CP)2:2436:MANPOS_RQST") #! Record("CEIC:CP$(CP)2:2436:MODE_STATUS",1740,2639,0,1,"CEIC:CP$(CP)2:2436:MODE_STATUS") #! Record("CEIC:CP$(CP)2:2436:INTERLOCKED",2460,2686,0,0,"CEIC:CP$(CP)2:2436:INTERLOCKED") #! Record("CEIC:CP$(CP)2:2436:INTERLOCK",2460,2506,0,0,"CEIC:CP$(CP)2:2436:INTERLOCK") #! Record("CEIC:CP$(CP)2:2436:IVAL",2641,2312,0,1,"CEIC:CP$(CP)2:2436:IVAL") #! Record("CEIC:CP$(CP)2:2436:SVAL",2820,2312,0,1,"CEIC:CP$(CP)2:2436:SVAL") #! Record("CEIC:CP$(CP)2:2436:MMOD",2102,2506,0,1,"CEIC:CP$(CP)2:2436:MMOD") #! Record("CEIC:CP$(CP)2:2436:SMOD",2282,2506,0,1,"CEIC:CP$(CP)2:2436:SMOD") #! Record("CEIC:CP$(CP)2:2436:MODE_STRING",1740,2314,0,1,"CEIC:CP$(CP)2:2436:MODE_STRING") #! Record("CEIC:CP$(CP)2:2436:PMOD",1922,2506,0,1,"CEIC:CP$(CP)2:2436:PMOD") #! Record("CEIC:CP$(CP)2:2436:IMOD",3020,2506,0,1,"CEIC:CP$(CP)2:2436:IMOD") #! Record("CEIC:CP$(CP)2:2436:ACTUATOR",1920,2322,0,1,"CEIC:CP$(CP)2:2436:ACTUATOR") #! Record("CEIC:CP$(CP)2:2436:PVAL",3000,2312,0,1,"CEIC:CP$(CP)2:2436:PVAL") #! Record("CEIC:CP$(CP)2:2436:CMD",3021,2112,0,1,"CEIC:CP$(CP)2:2436:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCEIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2436 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)2:2456:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2456:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2456:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)2:2456:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2456:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2456:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2456:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2456:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2456:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2456:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2456:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)2:2456:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2456:SP_RQST") { field(DESC, "C$(CP)PIC22456 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2456:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)2:2456:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC22456") } record(ao, "CPIC:CP$(CP)2:2456:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2456:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)2:2456:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)2:2456:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)2:2456:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)2:2456:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2456:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2456:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)2:2456:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)2:2456:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)2:2456:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)2:2456:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)2:2456:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)2:2456:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)2:2456:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)2:2456:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "EV22456") } record(ai, "CPIC:CP$(CP)2:2456:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)2:2456:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)2:2456:ORBV",2100,2312,0,1,"CPIC:CP$(CP)2:2456:ORBV") #! Record("CPIC:CP$(CP)2:2456:OVAL",2280,2312,0,1,"CPIC:CP$(CP)2:2456:OVAL") #! Record("CPIC:CP$(CP)2:2456:CVAL",2460,2312,0,1,"CPIC:CP$(CP)2:2456:CVAL") #! Record("CPIC:CP$(CP)2:2456:MAX",2122,1932,0,1,"CPIC:CP$(CP)2:2456:MAX") #! Record("CPIC:CP$(CP)2:2456:DMIN",2300,1932,0,1,"CPIC:CP$(CP)2:2456:DMIN") #! Record("CPIC:CP$(CP)2:2456:DMAX",2479,1932,0,1,"CPIC:CP$(CP)2:2456:DMAX") #! Record("CPIC:CP$(CP)2:2456:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)2:2456:MODE_RQST") #! Record("CPIC:CP$(CP)2:2456:MDT",2120,2112,0,1,"CPIC:CP$(CP)2:2456:MDT") #! Record("CPIC:CP$(CP)2:2456:KP",2300,2106,0,1,"CPIC:CP$(CP)2:2456:KP") #! Record("CPIC:CP$(CP)2:2456:KI",2480,2106,0,1,"CPIC:CP$(CP)2:2456:KI") #! Record("CPIC:CP$(CP)2:2456:KD",2660,2106,0,1,"CPIC:CP$(CP)2:2456:KD") #! Record("CPIC:CP$(CP)2:2456:S",2840,2120,0,1,"CPIC:CP$(CP)2:2456:S") #! Record("CPIC:CP$(CP)2:2456:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)2:2456:SP_RQST") #! Record("CPIC:CP$(CP)2:2456:MIN",1945,1932,0,1,"CPIC:CP$(CP)2:2456:MIN") #! Record("CPIC:CP$(CP)2:2456:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)2:2456:PIDTAG") #! Record("CPIC:CP$(CP)2:2456:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)2:2456:PEVAL") #! Record("CPIC:CP$(CP)2:2456:FSB",2840,1932,0,1,"CPIC:CP$(CP)2:2456:FSB") #! Record("CPIC:CP$(CP)2:2456:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)2:2456:NOMATCH") #! Record("CPIC:CP$(CP)2:2456:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)2:2456:CHFAULT") #! Record("CPIC:CP$(CP)2:2456:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)2:2456:MANPOS_RQST") #! Record("CPIC:CP$(CP)2:2456:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)2:2456:MODE_STATUS") #! Record("CPIC:CP$(CP)2:2456:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)2:2456:INTERLOCKED") #! Record("CPIC:CP$(CP)2:2456:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)2:2456:INTERLOCK") #! Record("CPIC:CP$(CP)2:2456:IVAL",2641,2312,0,1,"CPIC:CP$(CP)2:2456:IVAL") #! Record("CPIC:CP$(CP)2:2456:SVAL",2820,2312,0,1,"CPIC:CP$(CP)2:2456:SVAL") #! Record("CPIC:CP$(CP)2:2456:MMOD",2102,2506,0,1,"CPIC:CP$(CP)2:2456:MMOD") #! Record("CPIC:CP$(CP)2:2456:SMOD",2282,2506,0,1,"CPIC:CP$(CP)2:2456:SMOD") #! Record("CPIC:CP$(CP)2:2456:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)2:2456:MODE_STRING") #! Record("CPIC:CP$(CP)2:2456:PMOD",1922,2506,0,1,"CPIC:CP$(CP)2:2456:PMOD") #! Record("CPIC:CP$(CP)2:2456:IMOD",3020,2506,0,1,"CPIC:CP$(CP)2:2456:IMOD") #! Record("CPIC:CP$(CP)2:2456:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)2:2456:ACTUATOR") #! Record("CPIC:CP$(CP)2:2456:PVAL",3000,2312,0,1,"CPIC:CP$(CP)2:2456:PVAL") #! Record("CPIC:CP$(CP)2:2456:CMD",3021,2112,0,1,"CPIC:CP$(CP)2:2456:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2456 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CEIC:CP$(CP)2:2456:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CEIC:CP$(CP)2:2456:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CEIC:CP$(CP)2:2456:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A.CVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ao, "CEIC:CP$(CP)2:2456:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2456:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2456:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CEIC:CP$(CP)2:2456:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2456:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2456:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2456:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2456:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CEIC:CP$(CP)2:2456:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2456:SP_RQST") { field(DESC, "C$(CP)EIC22456 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A_OVH.SP_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2456:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CEIC:CP$(CP)2:2456:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)EIC22456") } record(ao, "CEIC:CP$(CP)2:2456:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CEIC:CP$(CP)2:2456:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CEIC:CP$(CP)2:2456:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CEIC:CP$(CP)2:2456:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CEIC:CP$(CP)2:2456:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CEIC:CP$(CP)2:2456:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CEIC:CP$(CP)2:2456:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CEIC:CP$(CP)2:2456:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CEIC:CP$(CP)2:2456:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CEIC:CP$(CP)2:2456:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CEIC:CP$(CP)2:2456:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CEIC:CP$(CP)2:2456:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CEIC:CP$(CP)2:2456:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A_OVH.Mode_String") } record(bi, "CEIC:CP$(CP)2:2456:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CEIC:CP$(CP)2:2456:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CEIC:CP$(CP)2:2456:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "EV22456A") } record(ai, "CEIC:CP$(CP)2:2456:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22456A.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CEIC:CP$(CP)2:2456:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22456A.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CEIC:CP$(CP)2:2456:ORBV",2100,2312,0,1,"CEIC:CP$(CP)2:2456:ORBV") #! Record("CEIC:CP$(CP)2:2456:OVAL",2280,2312,0,1,"CEIC:CP$(CP)2:2456:OVAL") #! Record("CEIC:CP$(CP)2:2456:CVAL",2460,2312,0,1,"CEIC:CP$(CP)2:2456:CVAL") #! Record("CEIC:CP$(CP)2:2456:MAX",2122,1932,0,1,"CEIC:CP$(CP)2:2456:MAX") #! Record("CEIC:CP$(CP)2:2456:DMIN",2300,1932,0,1,"CEIC:CP$(CP)2:2456:DMIN") #! Record("CEIC:CP$(CP)2:2456:DMAX",2479,1932,0,1,"CEIC:CP$(CP)2:2456:DMAX") #! Record("CEIC:CP$(CP)2:2456:MODE_RQST",1760,2112,0,1,"CEIC:CP$(CP)2:2456:MODE_RQST") #! Record("CEIC:CP$(CP)2:2456:MDT",2120,2112,0,1,"CEIC:CP$(CP)2:2456:MDT") #! Record("CEIC:CP$(CP)2:2456:KP",2300,2106,0,1,"CEIC:CP$(CP)2:2456:KP") #! Record("CEIC:CP$(CP)2:2456:KI",2480,2106,0,1,"CEIC:CP$(CP)2:2456:KI") #! Record("CEIC:CP$(CP)2:2456:KD",2660,2106,0,1,"CEIC:CP$(CP)2:2456:KD") #! Record("CEIC:CP$(CP)2:2456:S",2840,2120,0,1,"CEIC:CP$(CP)2:2456:S") #! Record("CEIC:CP$(CP)2:2456:SP_RQST",1760,1932,0,1,"CEIC:CP$(CP)2:2456:SP_RQST") #! Record("CEIC:CP$(CP)2:2456:MIN",1945,1932,0,1,"CEIC:CP$(CP)2:2456:MIN") #! Record("CEIC:CP$(CP)2:2456:PIDTAG",1740,2462,0,1,"CEIC:CP$(CP)2:2456:PIDTAG") #! Record("CEIC:CP$(CP)2:2456:PEVAL",2660,1932,0,1,"CEIC:CP$(CP)2:2456:PEVAL") #! Record("CEIC:CP$(CP)2:2456:FSB",2840,1932,0,1,"CEIC:CP$(CP)2:2456:FSB") #! Record("CEIC:CP$(CP)2:2456:NOMATCH",2640,2506,0,1,"CEIC:CP$(CP)2:2456:NOMATCH") #! Record("CEIC:CP$(CP)2:2456:CHFAULT",2820,2506,0,1,"CEIC:CP$(CP)2:2456:CHFAULT") #! Record("CEIC:CP$(CP)2:2456:MANPOS_RQST",1940,2112,0,1,"CEIC:CP$(CP)2:2456:MANPOS_RQST") #! Record("CEIC:CP$(CP)2:2456:MODE_STATUS",1740,2639,0,1,"CEIC:CP$(CP)2:2456:MODE_STATUS") #! Record("CEIC:CP$(CP)2:2456:INTERLOCKED",2460,2686,0,0,"CEIC:CP$(CP)2:2456:INTERLOCKED") #! Record("CEIC:CP$(CP)2:2456:INTERLOCK",2460,2506,0,0,"CEIC:CP$(CP)2:2456:INTERLOCK") #! Record("CEIC:CP$(CP)2:2456:IVAL",2641,2312,0,1,"CEIC:CP$(CP)2:2456:IVAL") #! Record("CEIC:CP$(CP)2:2456:SVAL",2820,2312,0,1,"CEIC:CP$(CP)2:2456:SVAL") #! Record("CEIC:CP$(CP)2:2456:MMOD",2102,2506,0,1,"CEIC:CP$(CP)2:2456:MMOD") #! Record("CEIC:CP$(CP)2:2456:SMOD",2282,2506,0,1,"CEIC:CP$(CP)2:2456:SMOD") #! Record("CEIC:CP$(CP)2:2456:MODE_STRING",1740,2314,0,1,"CEIC:CP$(CP)2:2456:MODE_STRING") #! Record("CEIC:CP$(CP)2:2456:PMOD",1922,2506,0,1,"CEIC:CP$(CP)2:2456:PMOD") #! Record("CEIC:CP$(CP)2:2456:IMOD",3020,2506,0,1,"CEIC:CP$(CP)2:2456:IMOD") #! Record("CEIC:CP$(CP)2:2456:ACTUATOR",1920,2322,0,1,"CEIC:CP$(CP)2:2456:ACTUATOR") #! Record("CEIC:CP$(CP)2:2456:PVAL",3000,2312,0,1,"CEIC:CP$(CP)2:2456:PVAL") #! Record("CEIC:CP$(CP)2:2456:CMD",3021,2112,0,1,"CEIC:CP$(CP)2:2456:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCEIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2456 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)2:2476:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2476:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2476:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)2:2476:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2476:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2476:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2476:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2476:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2476:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2476:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2476:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)2:2476:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2476:SP_RQST") { field(DESC, "C$(CP)PIC22476 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2476:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)2:2476:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC22476") } record(ao, "CPIC:CP$(CP)2:2476:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2476:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)2:2476:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)2:2476:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)2:2476:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)2:2476:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2476:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2476:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)2:2476:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)2:2476:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)2:2476:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)2:2476:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)2:2476:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)2:2476:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)2:2476:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)2:2476:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "EV22476") } record(ai, "CPIC:CP$(CP)2:2476:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)2:2476:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)2:2476:ORBV",2100,2312,0,1,"CPIC:CP$(CP)2:2476:ORBV") #! Record("CPIC:CP$(CP)2:2476:OVAL",2280,2312,0,1,"CPIC:CP$(CP)2:2476:OVAL") #! Record("CPIC:CP$(CP)2:2476:CVAL",2460,2312,0,1,"CPIC:CP$(CP)2:2476:CVAL") #! Record("CPIC:CP$(CP)2:2476:MAX",2122,1932,0,1,"CPIC:CP$(CP)2:2476:MAX") #! Record("CPIC:CP$(CP)2:2476:DMIN",2300,1932,0,1,"CPIC:CP$(CP)2:2476:DMIN") #! Record("CPIC:CP$(CP)2:2476:DMAX",2479,1932,0,1,"CPIC:CP$(CP)2:2476:DMAX") #! Record("CPIC:CP$(CP)2:2476:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)2:2476:MODE_RQST") #! Record("CPIC:CP$(CP)2:2476:MDT",2120,2112,0,1,"CPIC:CP$(CP)2:2476:MDT") #! Record("CPIC:CP$(CP)2:2476:KP",2300,2106,0,1,"CPIC:CP$(CP)2:2476:KP") #! Record("CPIC:CP$(CP)2:2476:KI",2480,2106,0,1,"CPIC:CP$(CP)2:2476:KI") #! Record("CPIC:CP$(CP)2:2476:KD",2660,2106,0,1,"CPIC:CP$(CP)2:2476:KD") #! Record("CPIC:CP$(CP)2:2476:S",2840,2120,0,1,"CPIC:CP$(CP)2:2476:S") #! Record("CPIC:CP$(CP)2:2476:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)2:2476:SP_RQST") #! Record("CPIC:CP$(CP)2:2476:MIN",1945,1932,0,1,"CPIC:CP$(CP)2:2476:MIN") #! Record("CPIC:CP$(CP)2:2476:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)2:2476:PIDTAG") #! Record("CPIC:CP$(CP)2:2476:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)2:2476:PEVAL") #! Record("CPIC:CP$(CP)2:2476:FSB",2840,1932,0,1,"CPIC:CP$(CP)2:2476:FSB") #! Record("CPIC:CP$(CP)2:2476:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)2:2476:NOMATCH") #! Record("CPIC:CP$(CP)2:2476:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)2:2476:CHFAULT") #! Record("CPIC:CP$(CP)2:2476:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)2:2476:MANPOS_RQST") #! Record("CPIC:CP$(CP)2:2476:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)2:2476:MODE_STATUS") #! Record("CPIC:CP$(CP)2:2476:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)2:2476:INTERLOCKED") #! Record("CPIC:CP$(CP)2:2476:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)2:2476:INTERLOCK") #! Record("CPIC:CP$(CP)2:2476:IVAL",2641,2312,0,1,"CPIC:CP$(CP)2:2476:IVAL") #! Record("CPIC:CP$(CP)2:2476:SVAL",2820,2312,0,1,"CPIC:CP$(CP)2:2476:SVAL") #! Record("CPIC:CP$(CP)2:2476:MMOD",2102,2506,0,1,"CPIC:CP$(CP)2:2476:MMOD") #! Record("CPIC:CP$(CP)2:2476:SMOD",2282,2506,0,1,"CPIC:CP$(CP)2:2476:SMOD") #! Record("CPIC:CP$(CP)2:2476:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)2:2476:MODE_STRING") #! Record("CPIC:CP$(CP)2:2476:PMOD",1922,2506,0,1,"CPIC:CP$(CP)2:2476:PMOD") #! Record("CPIC:CP$(CP)2:2476:IMOD",3020,2506,0,1,"CPIC:CP$(CP)2:2476:IMOD") #! Record("CPIC:CP$(CP)2:2476:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)2:2476:ACTUATOR") #! Record("CPIC:CP$(CP)2:2476:PVAL",3000,2312,0,1,"CPIC:CP$(CP)2:2476:PVAL") #! Record("CPIC:CP$(CP)2:2476:CMD",3021,2112,0,1,"CPIC:CP$(CP)2:2476:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2476 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CEIC:CP$(CP)2:2476:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CEIC:CP$(CP)2:2476:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CEIC:CP$(CP)2:2476:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A.CVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ao, "CEIC:CP$(CP)2:2476:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2476:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2476:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CEIC:CP$(CP)2:2476:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2476:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2476:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2476:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2476:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CEIC:CP$(CP)2:2476:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2476:SP_RQST") { field(DESC, "C$(CP)EIC22476 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A_OVH.SP_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2476:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CEIC:CP$(CP)2:2476:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)EIC22476") } record(ao, "CEIC:CP$(CP)2:2476:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CEIC:CP$(CP)2:2476:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CEIC:CP$(CP)2:2476:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CEIC:CP$(CP)2:2476:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CEIC:CP$(CP)2:2476:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CEIC:CP$(CP)2:2476:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CEIC:CP$(CP)2:2476:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CEIC:CP$(CP)2:2476:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CEIC:CP$(CP)2:2476:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CEIC:CP$(CP)2:2476:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CEIC:CP$(CP)2:2476:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CEIC:CP$(CP)2:2476:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CEIC:CP$(CP)2:2476:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A_OVH.Mode_String") } record(bi, "CEIC:CP$(CP)2:2476:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CEIC:CP$(CP)2:2476:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CEIC:CP$(CP)2:2476:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "EV22476A") } record(ai, "CEIC:CP$(CP)2:2476:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22476A.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CEIC:CP$(CP)2:2476:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22476A.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CEIC:CP$(CP)2:2476:ORBV",2100,2312,0,1,"CEIC:CP$(CP)2:2476:ORBV") #! Record("CEIC:CP$(CP)2:2476:OVAL",2280,2312,0,1,"CEIC:CP$(CP)2:2476:OVAL") #! Record("CEIC:CP$(CP)2:2476:CVAL",2460,2312,0,1,"CEIC:CP$(CP)2:2476:CVAL") #! Record("CEIC:CP$(CP)2:2476:MAX",2122,1932,0,1,"CEIC:CP$(CP)2:2476:MAX") #! Record("CEIC:CP$(CP)2:2476:DMIN",2300,1932,0,1,"CEIC:CP$(CP)2:2476:DMIN") #! Record("CEIC:CP$(CP)2:2476:DMAX",2479,1932,0,1,"CEIC:CP$(CP)2:2476:DMAX") #! Record("CEIC:CP$(CP)2:2476:MODE_RQST",1760,2112,0,1,"CEIC:CP$(CP)2:2476:MODE_RQST") #! Record("CEIC:CP$(CP)2:2476:MDT",2120,2112,0,1,"CEIC:CP$(CP)2:2476:MDT") #! Record("CEIC:CP$(CP)2:2476:KP",2300,2106,0,1,"CEIC:CP$(CP)2:2476:KP") #! Record("CEIC:CP$(CP)2:2476:KI",2480,2106,0,1,"CEIC:CP$(CP)2:2476:KI") #! Record("CEIC:CP$(CP)2:2476:KD",2660,2106,0,1,"CEIC:CP$(CP)2:2476:KD") #! Record("CEIC:CP$(CP)2:2476:S",2840,2120,0,1,"CEIC:CP$(CP)2:2476:S") #! Record("CEIC:CP$(CP)2:2476:SP_RQST",1760,1932,0,1,"CEIC:CP$(CP)2:2476:SP_RQST") #! Record("CEIC:CP$(CP)2:2476:MIN",1945,1932,0,1,"CEIC:CP$(CP)2:2476:MIN") #! Record("CEIC:CP$(CP)2:2476:PIDTAG",1740,2462,0,1,"CEIC:CP$(CP)2:2476:PIDTAG") #! Record("CEIC:CP$(CP)2:2476:PEVAL",2660,1932,0,1,"CEIC:CP$(CP)2:2476:PEVAL") #! Record("CEIC:CP$(CP)2:2476:FSB",2840,1932,0,1,"CEIC:CP$(CP)2:2476:FSB") #! Record("CEIC:CP$(CP)2:2476:NOMATCH",2640,2506,0,1,"CEIC:CP$(CP)2:2476:NOMATCH") #! Record("CEIC:CP$(CP)2:2476:CHFAULT",2820,2506,0,1,"CEIC:CP$(CP)2:2476:CHFAULT") #! Record("CEIC:CP$(CP)2:2476:MANPOS_RQST",1940,2112,0,1,"CEIC:CP$(CP)2:2476:MANPOS_RQST") #! Record("CEIC:CP$(CP)2:2476:MODE_STATUS",1740,2639,0,1,"CEIC:CP$(CP)2:2476:MODE_STATUS") #! Record("CEIC:CP$(CP)2:2476:INTERLOCKED",2460,2686,0,0,"CEIC:CP$(CP)2:2476:INTERLOCKED") #! Record("CEIC:CP$(CP)2:2476:INTERLOCK",2460,2506,0,0,"CEIC:CP$(CP)2:2476:INTERLOCK") #! Record("CEIC:CP$(CP)2:2476:IVAL",2641,2312,0,1,"CEIC:CP$(CP)2:2476:IVAL") #! Record("CEIC:CP$(CP)2:2476:SVAL",2820,2312,0,1,"CEIC:CP$(CP)2:2476:SVAL") #! Record("CEIC:CP$(CP)2:2476:MMOD",2102,2506,0,1,"CEIC:CP$(CP)2:2476:MMOD") #! Record("CEIC:CP$(CP)2:2476:SMOD",2282,2506,0,1,"CEIC:CP$(CP)2:2476:SMOD") #! Record("CEIC:CP$(CP)2:2476:MODE_STRING",1740,2314,0,1,"CEIC:CP$(CP)2:2476:MODE_STRING") #! Record("CEIC:CP$(CP)2:2476:PMOD",1922,2506,0,1,"CEIC:CP$(CP)2:2476:PMOD") #! Record("CEIC:CP$(CP)2:2476:IMOD",3020,2506,0,1,"CEIC:CP$(CP)2:2476:IMOD") #! Record("CEIC:CP$(CP)2:2476:ACTUATOR",1920,2322,0,1,"CEIC:CP$(CP)2:2476:ACTUATOR") #! Record("CEIC:CP$(CP)2:2476:PVAL",3000,2312,0,1,"CEIC:CP$(CP)2:2476:PVAL") #! Record("CEIC:CP$(CP)2:2476:CMD",3021,2112,0,1,"CEIC:CP$(CP)2:2476:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCEIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2476 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)2:2486:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2486:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2486:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)2:2486:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2486:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2486:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2486:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2486:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2486:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2486:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2486:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)2:2486:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2486:SP_RQST") { field(DESC, "C$(CP)PIC22486 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2486:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)2:2486:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC22486") } record(ao, "CPIC:CP$(CP)2:2486:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2486:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)2:2486:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)2:2486:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)2:2486:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)2:2486:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2486:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2486:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)2:2486:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)2:2486:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)2:2486:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)2:2486:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)2:2486:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)2:2486:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)2:2486:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)2:2486:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "EV22486") } record(ai, "CPIC:CP$(CP)2:2486:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)2:2486:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)2:2486:ORBV",2100,2312,0,1,"CPIC:CP$(CP)2:2486:ORBV") #! Record("CPIC:CP$(CP)2:2486:OVAL",2280,2312,0,1,"CPIC:CP$(CP)2:2486:OVAL") #! Record("CPIC:CP$(CP)2:2486:CVAL",2460,2312,0,1,"CPIC:CP$(CP)2:2486:CVAL") #! Record("CPIC:CP$(CP)2:2486:MAX",2122,1932,0,1,"CPIC:CP$(CP)2:2486:MAX") #! Record("CPIC:CP$(CP)2:2486:DMIN",2300,1932,0,1,"CPIC:CP$(CP)2:2486:DMIN") #! Record("CPIC:CP$(CP)2:2486:DMAX",2479,1932,0,1,"CPIC:CP$(CP)2:2486:DMAX") #! Record("CPIC:CP$(CP)2:2486:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)2:2486:MODE_RQST") #! Record("CPIC:CP$(CP)2:2486:MDT",2120,2112,0,1,"CPIC:CP$(CP)2:2486:MDT") #! Record("CPIC:CP$(CP)2:2486:KP",2300,2106,0,1,"CPIC:CP$(CP)2:2486:KP") #! Record("CPIC:CP$(CP)2:2486:KI",2480,2106,0,1,"CPIC:CP$(CP)2:2486:KI") #! Record("CPIC:CP$(CP)2:2486:KD",2660,2106,0,1,"CPIC:CP$(CP)2:2486:KD") #! Record("CPIC:CP$(CP)2:2486:S",2840,2120,0,1,"CPIC:CP$(CP)2:2486:S") #! Record("CPIC:CP$(CP)2:2486:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)2:2486:SP_RQST") #! Record("CPIC:CP$(CP)2:2486:MIN",1945,1932,0,1,"CPIC:CP$(CP)2:2486:MIN") #! Record("CPIC:CP$(CP)2:2486:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)2:2486:PIDTAG") #! Record("CPIC:CP$(CP)2:2486:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)2:2486:PEVAL") #! Record("CPIC:CP$(CP)2:2486:FSB",2840,1932,0,1,"CPIC:CP$(CP)2:2486:FSB") #! Record("CPIC:CP$(CP)2:2486:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)2:2486:NOMATCH") #! Record("CPIC:CP$(CP)2:2486:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)2:2486:CHFAULT") #! Record("CPIC:CP$(CP)2:2486:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)2:2486:MANPOS_RQST") #! Record("CPIC:CP$(CP)2:2486:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)2:2486:MODE_STATUS") #! Record("CPIC:CP$(CP)2:2486:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)2:2486:INTERLOCKED") #! Record("CPIC:CP$(CP)2:2486:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)2:2486:INTERLOCK") #! Record("CPIC:CP$(CP)2:2486:IVAL",2641,2312,0,1,"CPIC:CP$(CP)2:2486:IVAL") #! Record("CPIC:CP$(CP)2:2486:SVAL",2820,2312,0,1,"CPIC:CP$(CP)2:2486:SVAL") #! Record("CPIC:CP$(CP)2:2486:MMOD",2102,2506,0,1,"CPIC:CP$(CP)2:2486:MMOD") #! Record("CPIC:CP$(CP)2:2486:SMOD",2282,2506,0,1,"CPIC:CP$(CP)2:2486:SMOD") #! Record("CPIC:CP$(CP)2:2486:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)2:2486:MODE_STRING") #! Record("CPIC:CP$(CP)2:2486:PMOD",1922,2506,0,1,"CPIC:CP$(CP)2:2486:PMOD") #! Record("CPIC:CP$(CP)2:2486:IMOD",3020,2506,0,1,"CPIC:CP$(CP)2:2486:IMOD") #! Record("CPIC:CP$(CP)2:2486:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)2:2486:ACTUATOR") #! Record("CPIC:CP$(CP)2:2486:PVAL",3000,2312,0,1,"CPIC:CP$(CP)2:2486:PVAL") #! Record("CPIC:CP$(CP)2:2486:CMD",3021,2112,0,1,"CPIC:CP$(CP)2:2486:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2486 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CEIC:CP$(CP)2:2486:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CEIC:CP$(CP)2:2486:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CEIC:CP$(CP)2:2486:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A.CVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ao, "CEIC:CP$(CP)2:2486:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2486:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2486:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CEIC:CP$(CP)2:2486:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2486:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2486:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2486:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2486:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CEIC:CP$(CP)2:2486:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2486:SP_RQST") { field(DESC, "C$(CP)EIC22486 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A_OVH.SP_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CEIC:CP$(CP)2:2486:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CEIC:CP$(CP)2:2486:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)EIC22486") } record(ao, "CEIC:CP$(CP)2:2486:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CEIC:CP$(CP)2:2486:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CEIC:CP$(CP)2:2486:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CEIC:CP$(CP)2:2486:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CEIC:CP$(CP)2:2486:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CEIC:CP$(CP)2:2486:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CEIC:CP$(CP)2:2486:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CEIC:CP$(CP)2:2486:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CEIC:CP$(CP)2:2486:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CEIC:CP$(CP)2:2486:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CEIC:CP$(CP)2:2486:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CEIC:CP$(CP)2:2486:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CEIC:CP$(CP)2:2486:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A_OVH.Mode_String") } record(bi, "CEIC:CP$(CP)2:2486:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CEIC:CP$(CP)2:2486:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CEIC:CP$(CP)2:2486:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "EV22486A") } record(ai, "CEIC:CP$(CP)2:2486:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EV22486A.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CEIC:CP$(CP)2:2486:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EV22486A.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CEIC:CP$(CP)2:2486:ORBV",2100,2312,0,1,"CEIC:CP$(CP)2:2486:ORBV") #! Record("CEIC:CP$(CP)2:2486:OVAL",2280,2312,0,1,"CEIC:CP$(CP)2:2486:OVAL") #! Record("CEIC:CP$(CP)2:2486:CVAL",2460,2312,0,1,"CEIC:CP$(CP)2:2486:CVAL") #! Record("CEIC:CP$(CP)2:2486:MAX",2122,1932,0,1,"CEIC:CP$(CP)2:2486:MAX") #! Record("CEIC:CP$(CP)2:2486:DMIN",2300,1932,0,1,"CEIC:CP$(CP)2:2486:DMIN") #! Record("CEIC:CP$(CP)2:2486:DMAX",2479,1932,0,1,"CEIC:CP$(CP)2:2486:DMAX") #! Record("CEIC:CP$(CP)2:2486:MODE_RQST",1760,2112,0,1,"CEIC:CP$(CP)2:2486:MODE_RQST") #! Record("CEIC:CP$(CP)2:2486:MDT",2120,2112,0,1,"CEIC:CP$(CP)2:2486:MDT") #! Record("CEIC:CP$(CP)2:2486:KP",2300,2106,0,1,"CEIC:CP$(CP)2:2486:KP") #! Record("CEIC:CP$(CP)2:2486:KI",2480,2106,0,1,"CEIC:CP$(CP)2:2486:KI") #! Record("CEIC:CP$(CP)2:2486:KD",2660,2106,0,1,"CEIC:CP$(CP)2:2486:KD") #! Record("CEIC:CP$(CP)2:2486:S",2840,2120,0,1,"CEIC:CP$(CP)2:2486:S") #! Record("CEIC:CP$(CP)2:2486:SP_RQST",1760,1932,0,1,"CEIC:CP$(CP)2:2486:SP_RQST") #! Record("CEIC:CP$(CP)2:2486:MIN",1945,1932,0,1,"CEIC:CP$(CP)2:2486:MIN") #! Record("CEIC:CP$(CP)2:2486:PIDTAG",1740,2462,0,1,"CEIC:CP$(CP)2:2486:PIDTAG") #! Record("CEIC:CP$(CP)2:2486:PEVAL",2660,1932,0,1,"CEIC:CP$(CP)2:2486:PEVAL") #! Record("CEIC:CP$(CP)2:2486:FSB",2840,1932,0,1,"CEIC:CP$(CP)2:2486:FSB") #! Record("CEIC:CP$(CP)2:2486:NOMATCH",2640,2506,0,1,"CEIC:CP$(CP)2:2486:NOMATCH") #! Record("CEIC:CP$(CP)2:2486:CHFAULT",2820,2506,0,1,"CEIC:CP$(CP)2:2486:CHFAULT") #! Record("CEIC:CP$(CP)2:2486:MANPOS_RQST",1940,2112,0,1,"CEIC:CP$(CP)2:2486:MANPOS_RQST") #! Record("CEIC:CP$(CP)2:2486:MODE_STATUS",1740,2639,0,1,"CEIC:CP$(CP)2:2486:MODE_STATUS") #! Record("CEIC:CP$(CP)2:2486:INTERLOCKED",2460,2686,0,0,"CEIC:CP$(CP)2:2486:INTERLOCKED") #! Record("CEIC:CP$(CP)2:2486:INTERLOCK",2460,2506,0,0,"CEIC:CP$(CP)2:2486:INTERLOCK") #! Record("CEIC:CP$(CP)2:2486:IVAL",2641,2312,0,1,"CEIC:CP$(CP)2:2486:IVAL") #! Record("CEIC:CP$(CP)2:2486:SVAL",2820,2312,0,1,"CEIC:CP$(CP)2:2486:SVAL") #! Record("CEIC:CP$(CP)2:2486:MMOD",2102,2506,0,1,"CEIC:CP$(CP)2:2486:MMOD") #! Record("CEIC:CP$(CP)2:2486:SMOD",2282,2506,0,1,"CEIC:CP$(CP)2:2486:SMOD") #! Record("CEIC:CP$(CP)2:2486:MODE_STRING",1740,2314,0,1,"CEIC:CP$(CP)2:2486:MODE_STRING") #! Record("CEIC:CP$(CP)2:2486:PMOD",1922,2506,0,1,"CEIC:CP$(CP)2:2486:PMOD") #! Record("CEIC:CP$(CP)2:2486:IMOD",3020,2506,0,1,"CEIC:CP$(CP)2:2486:IMOD") #! Record("CEIC:CP$(CP)2:2486:ACTUATOR",1920,2322,0,1,"CEIC:CP$(CP)2:2486:ACTUATOR") #! Record("CEIC:CP$(CP)2:2486:PVAL",3000,2312,0,1,"CEIC:CP$(CP)2:2486:PVAL") #! Record("CEIC:CP$(CP)2:2486:CMD",3021,2112,0,1,"CEIC:CP$(CP)2:2486:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCEIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2486 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)2:2485:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2485:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2485:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)2:2485:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2485:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2485:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2485:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2485:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2485:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2485:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2485:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)2:2485:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2485:SP_RQST") { field(DESC, "C$(CP)PIC22485 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2485:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)2:2485:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC22485") } record(ao, "CPIC:CP$(CP)2:2485:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2485:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)2:2485:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)2:2485:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)2:2485:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)2:2485:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2485:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2485:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)2:2485:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)2:2485:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)2:2485:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)2:2485:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)2:2485:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)2:2485:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)2:2485:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)2:2485:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22485") } record(ai, "CPIC:CP$(CP)2:2485:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)2:2485:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)2:2485:ORBV",2100,2312,0,1,"CPIC:CP$(CP)2:2485:ORBV") #! Record("CPIC:CP$(CP)2:2485:OVAL",2280,2312,0,1,"CPIC:CP$(CP)2:2485:OVAL") #! Record("CPIC:CP$(CP)2:2485:CVAL",2460,2312,0,1,"CPIC:CP$(CP)2:2485:CVAL") #! Record("CPIC:CP$(CP)2:2485:MAX",2122,1932,0,1,"CPIC:CP$(CP)2:2485:MAX") #! Record("CPIC:CP$(CP)2:2485:DMIN",2300,1932,0,1,"CPIC:CP$(CP)2:2485:DMIN") #! Record("CPIC:CP$(CP)2:2485:DMAX",2479,1932,0,1,"CPIC:CP$(CP)2:2485:DMAX") #! Record("CPIC:CP$(CP)2:2485:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)2:2485:MODE_RQST") #! Record("CPIC:CP$(CP)2:2485:MDT",2120,2112,0,1,"CPIC:CP$(CP)2:2485:MDT") #! Record("CPIC:CP$(CP)2:2485:KP",2300,2106,0,1,"CPIC:CP$(CP)2:2485:KP") #! Record("CPIC:CP$(CP)2:2485:KI",2480,2106,0,1,"CPIC:CP$(CP)2:2485:KI") #! Record("CPIC:CP$(CP)2:2485:KD",2660,2106,0,1,"CPIC:CP$(CP)2:2485:KD") #! Record("CPIC:CP$(CP)2:2485:S",2840,2120,0,1,"CPIC:CP$(CP)2:2485:S") #! Record("CPIC:CP$(CP)2:2485:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)2:2485:SP_RQST") #! Record("CPIC:CP$(CP)2:2485:MIN",1945,1932,0,1,"CPIC:CP$(CP)2:2485:MIN") #! Record("CPIC:CP$(CP)2:2485:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)2:2485:PIDTAG") #! Record("CPIC:CP$(CP)2:2485:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)2:2485:PEVAL") #! Record("CPIC:CP$(CP)2:2485:FSB",2840,1932,0,1,"CPIC:CP$(CP)2:2485:FSB") #! Record("CPIC:CP$(CP)2:2485:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)2:2485:NOMATCH") #! Record("CPIC:CP$(CP)2:2485:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)2:2485:CHFAULT") #! Record("CPIC:CP$(CP)2:2485:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)2:2485:MANPOS_RQST") #! Record("CPIC:CP$(CP)2:2485:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)2:2485:MODE_STATUS") #! Record("CPIC:CP$(CP)2:2485:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)2:2485:INTERLOCKED") #! Record("CPIC:CP$(CP)2:2485:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)2:2485:INTERLOCK") #! Record("CPIC:CP$(CP)2:2485:IVAL",2641,2312,0,1,"CPIC:CP$(CP)2:2485:IVAL") #! Record("CPIC:CP$(CP)2:2485:SVAL",2820,2312,0,1,"CPIC:CP$(CP)2:2485:SVAL") #! Record("CPIC:CP$(CP)2:2485:MMOD",2102,2506,0,1,"CPIC:CP$(CP)2:2485:MMOD") #! Record("CPIC:CP$(CP)2:2485:SMOD",2282,2506,0,1,"CPIC:CP$(CP)2:2485:SMOD") #! Record("CPIC:CP$(CP)2:2485:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)2:2485:MODE_STRING") #! Record("CPIC:CP$(CP)2:2485:PMOD",1922,2506,0,1,"CPIC:CP$(CP)2:2485:PMOD") #! Record("CPIC:CP$(CP)2:2485:IMOD",3020,2506,0,1,"CPIC:CP$(CP)2:2485:IMOD") #! Record("CPIC:CP$(CP)2:2485:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)2:2485:ACTUATOR") #! Record("CPIC:CP$(CP)2:2485:PVAL",3000,2312,0,1,"CPIC:CP$(CP)2:2485:PVAL") #! Record("CPIC:CP$(CP)2:2485:CMD",3021,2112,0,1,"CPIC:CP$(CP)2:2485:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2485 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CTIC:CP$(CP)2:2485:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2485:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2485:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A.CVAL") field(PREC, "2") field(EGU, "K") field(ADEL, ".01") } record(ao, "CTIC:CP$(CP)2:2485:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2485:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2485:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2485:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2485:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2485:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2485:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2485:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CTIC:CP$(CP)2:2485:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2485:SP_RQST") { field(DESC, "C$(CP)TIC22485 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A_OVH.SP_Rqst") field(PREC, "2") field(EGU, "K") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2485:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CTIC:CP$(CP)2:2485:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)TIC22485") } record(ao, "CTIC:CP$(CP)2:2485:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2485:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CTIC:CP$(CP)2:2485:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CTIC:CP$(CP)2:2485:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CTIC:CP$(CP)2:2485:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CTIC:CP$(CP)2:2485:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2485:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2485:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CTIC:CP$(CP)2:2485:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CTIC:CP$(CP)2:2485:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CTIC:CP$(CP)2:2485:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CTIC:CP$(CP)2:2485:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CTIC:CP$(CP)2:2485:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A_OVH.Mode_String") } record(bi, "CTIC:CP$(CP)2:2485:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CTIC:CP$(CP)2:2485:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CTIC:CP$(CP)2:2485:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22485A") } record(ai, "CTIC:CP$(CP)2:2485:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22485A.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CTIC:CP$(CP)2:2485:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22485A.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CTIC:CP$(CP)2:2485:ORBV",2100,2312,0,1,"CTIC:CP$(CP)2:2485:ORBV") #! Record("CTIC:CP$(CP)2:2485:OVAL",2280,2312,0,1,"CTIC:CP$(CP)2:2485:OVAL") #! Record("CTIC:CP$(CP)2:2485:CVAL",2460,2312,0,1,"CTIC:CP$(CP)2:2485:CVAL") #! Record("CTIC:CP$(CP)2:2485:MAX",2122,1932,0,1,"CTIC:CP$(CP)2:2485:MAX") #! Record("CTIC:CP$(CP)2:2485:DMIN",2300,1932,0,1,"CTIC:CP$(CP)2:2485:DMIN") #! Record("CTIC:CP$(CP)2:2485:DMAX",2479,1932,0,1,"CTIC:CP$(CP)2:2485:DMAX") #! Record("CTIC:CP$(CP)2:2485:MODE_RQST",1760,2112,0,1,"CTIC:CP$(CP)2:2485:MODE_RQST") #! Record("CTIC:CP$(CP)2:2485:MDT",2120,2112,0,1,"CTIC:CP$(CP)2:2485:MDT") #! Record("CTIC:CP$(CP)2:2485:KP",2300,2106,0,1,"CTIC:CP$(CP)2:2485:KP") #! Record("CTIC:CP$(CP)2:2485:KI",2480,2106,0,1,"CTIC:CP$(CP)2:2485:KI") #! Record("CTIC:CP$(CP)2:2485:KD",2660,2106,0,1,"CTIC:CP$(CP)2:2485:KD") #! Record("CTIC:CP$(CP)2:2485:S",2840,2120,0,1,"CTIC:CP$(CP)2:2485:S") #! Record("CTIC:CP$(CP)2:2485:SP_RQST",1760,1932,0,1,"CTIC:CP$(CP)2:2485:SP_RQST") #! Record("CTIC:CP$(CP)2:2485:MIN",1945,1932,0,1,"CTIC:CP$(CP)2:2485:MIN") #! Record("CTIC:CP$(CP)2:2485:PIDTAG",1740,2462,0,1,"CTIC:CP$(CP)2:2485:PIDTAG") #! Record("CTIC:CP$(CP)2:2485:PEVAL",2660,1932,0,1,"CTIC:CP$(CP)2:2485:PEVAL") #! Record("CTIC:CP$(CP)2:2485:FSB",2840,1932,0,1,"CTIC:CP$(CP)2:2485:FSB") #! Record("CTIC:CP$(CP)2:2485:NOMATCH",2640,2506,0,1,"CTIC:CP$(CP)2:2485:NOMATCH") #! Record("CTIC:CP$(CP)2:2485:CHFAULT",2820,2506,0,1,"CTIC:CP$(CP)2:2485:CHFAULT") #! Record("CTIC:CP$(CP)2:2485:MANPOS_RQST",1940,2112,0,1,"CTIC:CP$(CP)2:2485:MANPOS_RQST") #! Record("CTIC:CP$(CP)2:2485:MODE_STATUS",1740,2639,0,1,"CTIC:CP$(CP)2:2485:MODE_STATUS") #! Record("CTIC:CP$(CP)2:2485:INTERLOCKED",2460,2686,0,0,"CTIC:CP$(CP)2:2485:INTERLOCKED") #! Record("CTIC:CP$(CP)2:2485:INTERLOCK",2460,2506,0,0,"CTIC:CP$(CP)2:2485:INTERLOCK") #! Record("CTIC:CP$(CP)2:2485:IVAL",2641,2312,0,1,"CTIC:CP$(CP)2:2485:IVAL") #! Record("CTIC:CP$(CP)2:2485:SVAL",2820,2312,0,1,"CTIC:CP$(CP)2:2485:SVAL") #! Record("CTIC:CP$(CP)2:2485:MMOD",2102,2506,0,1,"CTIC:CP$(CP)2:2485:MMOD") #! Record("CTIC:CP$(CP)2:2485:SMOD",2282,2506,0,1,"CTIC:CP$(CP)2:2485:SMOD") #! Record("CTIC:CP$(CP)2:2485:MODE_STRING",1740,2314,0,1,"CTIC:CP$(CP)2:2485:MODE_STRING") #! Record("CTIC:CP$(CP)2:2485:PMOD",1922,2506,0,1,"CTIC:CP$(CP)2:2485:PMOD") #! Record("CTIC:CP$(CP)2:2485:IMOD",3020,2506,0,1,"CTIC:CP$(CP)2:2485:IMOD") #! Record("CTIC:CP$(CP)2:2485:ACTUATOR",1920,2322,0,1,"CTIC:CP$(CP)2:2485:ACTUATOR") #! Record("CTIC:CP$(CP)2:2485:PVAL",3000,2312,0,1,"CTIC:CP$(CP)2:2485:PVAL") #! Record("CTIC:CP$(CP)2:2485:CMD",3021,2112,0,1,"CTIC:CP$(CP)2:2485:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCTIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2485 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CTIC:CP$(CP)2:2389:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2389:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2389:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389.CVAL") field(PREC, "2") field(EGU, "K") field(ADEL, ".01") } record(ao, "CTIC:CP$(CP)2:2389:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2389:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2389:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2389:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2389:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2389:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2389:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2389:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CTIC:CP$(CP)2:2389:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2389:SP_RQST") { field(DESC, "C$(CP)TIC22389 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389_OVH.SP_Rqst") field(PREC, "2") field(EGU, "K") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2389:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CTIC:CP$(CP)2:2389:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)TIC22389") } record(ao, "CTIC:CP$(CP)2:2389:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2389:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CTIC:CP$(CP)2:2389:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CTIC:CP$(CP)2:2389:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CTIC:CP$(CP)2:2389:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CTIC:CP$(CP)2:2389:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2389:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2389:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CTIC:CP$(CP)2:2389:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CTIC:CP$(CP)2:2389:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CTIC:CP$(CP)2:2389:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CTIC:CP$(CP)2:2389:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CTIC:CP$(CP)2:2389:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389_OVH.Mode_String") } record(bi, "CTIC:CP$(CP)2:2389:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CTIC:CP$(CP)2:2389:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CTIC:CP$(CP)2:2389:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22389") } record(ai, "CTIC:CP$(CP)2:2389:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22389.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CTIC:CP$(CP)2:2389:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22389.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CTIC:CP$(CP)2:2389:ORBV",2100,2312,0,1,"CTIC:CP$(CP)2:2389:ORBV") #! Record("CTIC:CP$(CP)2:2389:OVAL",2280,2312,0,1,"CTIC:CP$(CP)2:2389:OVAL") #! Record("CTIC:CP$(CP)2:2389:CVAL",2460,2312,0,1,"CTIC:CP$(CP)2:2389:CVAL") #! Record("CTIC:CP$(CP)2:2389:MAX",2122,1932,0,1,"CTIC:CP$(CP)2:2389:MAX") #! Record("CTIC:CP$(CP)2:2389:DMIN",2300,1932,0,1,"CTIC:CP$(CP)2:2389:DMIN") #! Record("CTIC:CP$(CP)2:2389:DMAX",2479,1932,0,1,"CTIC:CP$(CP)2:2389:DMAX") #! Record("CTIC:CP$(CP)2:2389:MODE_RQST",1760,2112,0,1,"CTIC:CP$(CP)2:2389:MODE_RQST") #! Record("CTIC:CP$(CP)2:2389:MDT",2120,2112,0,1,"CTIC:CP$(CP)2:2389:MDT") #! Record("CTIC:CP$(CP)2:2389:KP",2300,2106,0,1,"CTIC:CP$(CP)2:2389:KP") #! Record("CTIC:CP$(CP)2:2389:KI",2480,2106,0,1,"CTIC:CP$(CP)2:2389:KI") #! Record("CTIC:CP$(CP)2:2389:KD",2660,2106,0,1,"CTIC:CP$(CP)2:2389:KD") #! Record("CTIC:CP$(CP)2:2389:S",2840,2120,0,1,"CTIC:CP$(CP)2:2389:S") #! Record("CTIC:CP$(CP)2:2389:SP_RQST",1760,1932,0,1,"CTIC:CP$(CP)2:2389:SP_RQST") #! Record("CTIC:CP$(CP)2:2389:MIN",1945,1932,0,1,"CTIC:CP$(CP)2:2389:MIN") #! Record("CTIC:CP$(CP)2:2389:PIDTAG",1740,2462,0,1,"CTIC:CP$(CP)2:2389:PIDTAG") #! Record("CTIC:CP$(CP)2:2389:PEVAL",2660,1932,0,1,"CTIC:CP$(CP)2:2389:PEVAL") #! Record("CTIC:CP$(CP)2:2389:FSB",2840,1932,0,1,"CTIC:CP$(CP)2:2389:FSB") #! Record("CTIC:CP$(CP)2:2389:NOMATCH",2640,2506,0,1,"CTIC:CP$(CP)2:2389:NOMATCH") #! Record("CTIC:CP$(CP)2:2389:CHFAULT",2820,2506,0,1,"CTIC:CP$(CP)2:2389:CHFAULT") #! Record("CTIC:CP$(CP)2:2389:MANPOS_RQST",1940,2112,0,1,"CTIC:CP$(CP)2:2389:MANPOS_RQST") #! Record("CTIC:CP$(CP)2:2389:MODE_STATUS",1740,2639,0,1,"CTIC:CP$(CP)2:2389:MODE_STATUS") #! Record("CTIC:CP$(CP)2:2389:INTERLOCKED",2460,2686,0,0,"CTIC:CP$(CP)2:2389:INTERLOCKED") #! Record("CTIC:CP$(CP)2:2389:INTERLOCK",2460,2506,0,0,"CTIC:CP$(CP)2:2389:INTERLOCK") #! Record("CTIC:CP$(CP)2:2389:IVAL",2641,2312,0,1,"CTIC:CP$(CP)2:2389:IVAL") #! Record("CTIC:CP$(CP)2:2389:SVAL",2820,2312,0,1,"CTIC:CP$(CP)2:2389:SVAL") #! Record("CTIC:CP$(CP)2:2389:MMOD",2102,2506,0,1,"CTIC:CP$(CP)2:2389:MMOD") #! Record("CTIC:CP$(CP)2:2389:SMOD",2282,2506,0,1,"CTIC:CP$(CP)2:2389:SMOD") #! Record("CTIC:CP$(CP)2:2389:MODE_STRING",1740,2314,0,1,"CTIC:CP$(CP)2:2389:MODE_STRING") #! Record("CTIC:CP$(CP)2:2389:PMOD",1922,2506,0,1,"CTIC:CP$(CP)2:2389:PMOD") #! Record("CTIC:CP$(CP)2:2389:IMOD",3020,2506,0,1,"CTIC:CP$(CP)2:2389:IMOD") #! Record("CTIC:CP$(CP)2:2389:ACTUATOR",1920,2322,0,1,"CTIC:CP$(CP)2:2389:ACTUATOR") #! Record("CTIC:CP$(CP)2:2389:PVAL",3000,2312,0,1,"CTIC:CP$(CP)2:2389:PVAL") #! Record("CTIC:CP$(CP)2:2389:CMD",3021,2112,0,1,"CTIC:CP$(CP)2:2389:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCTIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2389 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CLIC:CP$(CP)2:2390:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CLIC:CP$(CP)2:2390:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CLIC:CP$(CP)2:2390:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390.CVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ao, "CLIC:CP$(CP)2:2390:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2390:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2390:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CLIC:CP$(CP)2:2390:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2390:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2390:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2390:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2390:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CLIC:CP$(CP)2:2390:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2390:SP_RQST") { field(DESC, "C$(CP)LIC22390 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390_OVH.SP_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2390:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CLIC:CP$(CP)2:2390:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)LIC22390") } record(ao, "CLIC:CP$(CP)2:2390:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CLIC:CP$(CP)2:2390:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CLIC:CP$(CP)2:2390:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CLIC:CP$(CP)2:2390:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CLIC:CP$(CP)2:2390:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CLIC:CP$(CP)2:2390:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CLIC:CP$(CP)2:2390:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CLIC:CP$(CP)2:2390:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CLIC:CP$(CP)2:2390:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CLIC:CP$(CP)2:2390:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CLIC:CP$(CP)2:2390:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CLIC:CP$(CP)2:2390:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CLIC:CP$(CP)2:2390:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390_OVH.Mode_String") } record(bi, "CLIC:CP$(CP)2:2390:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CLIC:CP$(CP)2:2390:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CLIC:CP$(CP)2:2390:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22390") } record(ai, "CLIC:CP$(CP)2:2390:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CLIC:CP$(CP)2:2390:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CLIC:CP$(CP)2:2390:ORBV",2100,2312,0,1,"CLIC:CP$(CP)2:2390:ORBV") #! Record("CLIC:CP$(CP)2:2390:OVAL",2280,2312,0,1,"CLIC:CP$(CP)2:2390:OVAL") #! Record("CLIC:CP$(CP)2:2390:CVAL",2460,2312,0,1,"CLIC:CP$(CP)2:2390:CVAL") #! Record("CLIC:CP$(CP)2:2390:MAX",2122,1932,0,1,"CLIC:CP$(CP)2:2390:MAX") #! Record("CLIC:CP$(CP)2:2390:DMIN",2300,1932,0,1,"CLIC:CP$(CP)2:2390:DMIN") #! Record("CLIC:CP$(CP)2:2390:DMAX",2479,1932,0,1,"CLIC:CP$(CP)2:2390:DMAX") #! Record("CLIC:CP$(CP)2:2390:MODE_RQST",1760,2112,0,1,"CLIC:CP$(CP)2:2390:MODE_RQST") #! Record("CLIC:CP$(CP)2:2390:MDT",2120,2112,0,1,"CLIC:CP$(CP)2:2390:MDT") #! Record("CLIC:CP$(CP)2:2390:KP",2300,2106,0,1,"CLIC:CP$(CP)2:2390:KP") #! Record("CLIC:CP$(CP)2:2390:KI",2480,2106,0,1,"CLIC:CP$(CP)2:2390:KI") #! Record("CLIC:CP$(CP)2:2390:KD",2660,2106,0,1,"CLIC:CP$(CP)2:2390:KD") #! Record("CLIC:CP$(CP)2:2390:S",2840,2120,0,1,"CLIC:CP$(CP)2:2390:S") #! Record("CLIC:CP$(CP)2:2390:SP_RQST",1760,1932,0,1,"CLIC:CP$(CP)2:2390:SP_RQST") #! Record("CLIC:CP$(CP)2:2390:MIN",1945,1932,0,1,"CLIC:CP$(CP)2:2390:MIN") #! Record("CLIC:CP$(CP)2:2390:PIDTAG",1740,2462,0,1,"CLIC:CP$(CP)2:2390:PIDTAG") #! Record("CLIC:CP$(CP)2:2390:PEVAL",2660,1932,0,1,"CLIC:CP$(CP)2:2390:PEVAL") #! Record("CLIC:CP$(CP)2:2390:FSB",2840,1932,0,1,"CLIC:CP$(CP)2:2390:FSB") #! Record("CLIC:CP$(CP)2:2390:NOMATCH",2640,2506,0,1,"CLIC:CP$(CP)2:2390:NOMATCH") #! Record("CLIC:CP$(CP)2:2390:CHFAULT",2820,2506,0,1,"CLIC:CP$(CP)2:2390:CHFAULT") #! Record("CLIC:CP$(CP)2:2390:MANPOS_RQST",1940,2112,0,1,"CLIC:CP$(CP)2:2390:MANPOS_RQST") #! Record("CLIC:CP$(CP)2:2390:MODE_STATUS",1740,2639,0,1,"CLIC:CP$(CP)2:2390:MODE_STATUS") #! Record("CLIC:CP$(CP)2:2390:INTERLOCKED",2460,2686,0,0,"CLIC:CP$(CP)2:2390:INTERLOCKED") #! Record("CLIC:CP$(CP)2:2390:INTERLOCK",2460,2506,0,0,"CLIC:CP$(CP)2:2390:INTERLOCK") #! Record("CLIC:CP$(CP)2:2390:IVAL",2641,2312,0,1,"CLIC:CP$(CP)2:2390:IVAL") #! Record("CLIC:CP$(CP)2:2390:SVAL",2820,2312,0,1,"CLIC:CP$(CP)2:2390:SVAL") #! Record("CLIC:CP$(CP)2:2390:MMOD",2102,2506,0,1,"CLIC:CP$(CP)2:2390:MMOD") #! Record("CLIC:CP$(CP)2:2390:SMOD",2282,2506,0,1,"CLIC:CP$(CP)2:2390:SMOD") #! Record("CLIC:CP$(CP)2:2390:MODE_STRING",1740,2314,0,1,"CLIC:CP$(CP)2:2390:MODE_STRING") #! Record("CLIC:CP$(CP)2:2390:PMOD",1922,2506,0,1,"CLIC:CP$(CP)2:2390:PMOD") #! Record("CLIC:CP$(CP)2:2390:IMOD",3020,2506,0,1,"CLIC:CP$(CP)2:2390:IMOD") #! Record("CLIC:CP$(CP)2:2390:ACTUATOR",1920,2322,0,1,"CLIC:CP$(CP)2:2390:ACTUATOR") #! Record("CLIC:CP$(CP)2:2390:PVAL",3000,2312,0,1,"CLIC:CP$(CP)2:2390:PVAL") #! Record("CLIC:CP$(CP)2:2390:CMD",3021,2112,0,1,"CLIC:CP$(CP)2:2390:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCLIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2390 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)2:2390:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2390:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2390:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)2:2390:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2390:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2390:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2390:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2390:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2390:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2390:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2390:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)2:2390:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2390:SP_RQST") { field(DESC, "C$(CP)PIC22390 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2390:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)2:2390:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC22390") } record(ao, "CPIC:CP$(CP)2:2390:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2390:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)2:2390:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)2:2390:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)2:2390:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)2:2390:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2390:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2390:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)2:2390:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)2:2390:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)2:2390:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)2:2390:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)2:2390:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)2:2390:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)2:2390:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)2:2390:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22390A") } record(ai, "CPIC:CP$(CP)2:2390:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22390A.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)2:2390:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22390A.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)2:2390:ORBV",2100,2312,0,1,"CPIC:CP$(CP)2:2390:ORBV") #! Record("CPIC:CP$(CP)2:2390:OVAL",2280,2312,0,1,"CPIC:CP$(CP)2:2390:OVAL") #! Record("CPIC:CP$(CP)2:2390:CVAL",2460,2312,0,1,"CPIC:CP$(CP)2:2390:CVAL") #! Record("CPIC:CP$(CP)2:2390:MAX",2122,1932,0,1,"CPIC:CP$(CP)2:2390:MAX") #! Record("CPIC:CP$(CP)2:2390:DMIN",2300,1932,0,1,"CPIC:CP$(CP)2:2390:DMIN") #! Record("CPIC:CP$(CP)2:2390:DMAX",2479,1932,0,1,"CPIC:CP$(CP)2:2390:DMAX") #! Record("CPIC:CP$(CP)2:2390:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)2:2390:MODE_RQST") #! Record("CPIC:CP$(CP)2:2390:MDT",2120,2112,0,1,"CPIC:CP$(CP)2:2390:MDT") #! Record("CPIC:CP$(CP)2:2390:KP",2300,2106,0,1,"CPIC:CP$(CP)2:2390:KP") #! Record("CPIC:CP$(CP)2:2390:KI",2480,2106,0,1,"CPIC:CP$(CP)2:2390:KI") #! Record("CPIC:CP$(CP)2:2390:KD",2660,2106,0,1,"CPIC:CP$(CP)2:2390:KD") #! Record("CPIC:CP$(CP)2:2390:S",2840,2120,0,1,"CPIC:CP$(CP)2:2390:S") #! Record("CPIC:CP$(CP)2:2390:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)2:2390:SP_RQST") #! Record("CPIC:CP$(CP)2:2390:MIN",1945,1932,0,1,"CPIC:CP$(CP)2:2390:MIN") #! Record("CPIC:CP$(CP)2:2390:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)2:2390:PIDTAG") #! Record("CPIC:CP$(CP)2:2390:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)2:2390:PEVAL") #! Record("CPIC:CP$(CP)2:2390:FSB",2840,1932,0,1,"CPIC:CP$(CP)2:2390:FSB") #! Record("CPIC:CP$(CP)2:2390:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)2:2390:NOMATCH") #! Record("CPIC:CP$(CP)2:2390:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)2:2390:CHFAULT") #! Record("CPIC:CP$(CP)2:2390:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)2:2390:MANPOS_RQST") #! Record("CPIC:CP$(CP)2:2390:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)2:2390:MODE_STATUS") #! Record("CPIC:CP$(CP)2:2390:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)2:2390:INTERLOCKED") #! Record("CPIC:CP$(CP)2:2390:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)2:2390:INTERLOCK") #! Record("CPIC:CP$(CP)2:2390:IVAL",2641,2312,0,1,"CPIC:CP$(CP)2:2390:IVAL") #! Record("CPIC:CP$(CP)2:2390:SVAL",2820,2312,0,1,"CPIC:CP$(CP)2:2390:SVAL") #! Record("CPIC:CP$(CP)2:2390:MMOD",2102,2506,0,1,"CPIC:CP$(CP)2:2390:MMOD") #! Record("CPIC:CP$(CP)2:2390:SMOD",2282,2506,0,1,"CPIC:CP$(CP)2:2390:SMOD") #! Record("CPIC:CP$(CP)2:2390:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)2:2390:MODE_STRING") #! Record("CPIC:CP$(CP)2:2390:PMOD",1922,2506,0,1,"CPIC:CP$(CP)2:2390:PMOD") #! Record("CPIC:CP$(CP)2:2390:IMOD",3020,2506,0,1,"CPIC:CP$(CP)2:2390:IMOD") #! Record("CPIC:CP$(CP)2:2390:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)2:2390:ACTUATOR") #! Record("CPIC:CP$(CP)2:2390:PVAL",3000,2312,0,1,"CPIC:CP$(CP)2:2390:PVAL") #! Record("CPIC:CP$(CP)2:2390:CMD",3021,2112,0,1,"CPIC:CP$(CP)2:2390:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2390 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)2:2391:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2391:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2391:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)2:2391:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2391:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2391:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2391:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2391:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2391:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2391:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2391:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)2:2391:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2391:SP_RQST") { field(DESC, "C$(CP)PIC22391 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2391:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)2:2391:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC22391") } record(ao, "CPIC:CP$(CP)2:2391:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2391:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)2:2391:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)2:2391:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)2:2391:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)2:2391:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2391:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2391:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)2:2391:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)2:2391:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)2:2391:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)2:2391:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)2:2391:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)2:2391:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)2:2391:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)2:2391:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22391") } record(ai, "CPIC:CP$(CP)2:2391:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22391.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)2:2391:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22391.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)2:2391:ORBV",2100,2312,0,1,"CPIC:CP$(CP)2:2391:ORBV") #! Record("CPIC:CP$(CP)2:2391:OVAL",2280,2312,0,1,"CPIC:CP$(CP)2:2391:OVAL") #! Record("CPIC:CP$(CP)2:2391:CVAL",2460,2312,0,1,"CPIC:CP$(CP)2:2391:CVAL") #! Record("CPIC:CP$(CP)2:2391:MAX",2122,1932,0,1,"CPIC:CP$(CP)2:2391:MAX") #! Record("CPIC:CP$(CP)2:2391:DMIN",2300,1932,0,1,"CPIC:CP$(CP)2:2391:DMIN") #! Record("CPIC:CP$(CP)2:2391:DMAX",2479,1932,0,1,"CPIC:CP$(CP)2:2391:DMAX") #! Record("CPIC:CP$(CP)2:2391:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)2:2391:MODE_RQST") #! Record("CPIC:CP$(CP)2:2391:MDT",2120,2112,0,1,"CPIC:CP$(CP)2:2391:MDT") #! Record("CPIC:CP$(CP)2:2391:KP",2300,2106,0,1,"CPIC:CP$(CP)2:2391:KP") #! Record("CPIC:CP$(CP)2:2391:KI",2480,2106,0,1,"CPIC:CP$(CP)2:2391:KI") #! Record("CPIC:CP$(CP)2:2391:KD",2660,2106,0,1,"CPIC:CP$(CP)2:2391:KD") #! Record("CPIC:CP$(CP)2:2391:S",2840,2120,0,1,"CPIC:CP$(CP)2:2391:S") #! Record("CPIC:CP$(CP)2:2391:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)2:2391:SP_RQST") #! Record("CPIC:CP$(CP)2:2391:MIN",1945,1932,0,1,"CPIC:CP$(CP)2:2391:MIN") #! Record("CPIC:CP$(CP)2:2391:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)2:2391:PIDTAG") #! Record("CPIC:CP$(CP)2:2391:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)2:2391:PEVAL") #! Record("CPIC:CP$(CP)2:2391:FSB",2840,1932,0,1,"CPIC:CP$(CP)2:2391:FSB") #! Record("CPIC:CP$(CP)2:2391:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)2:2391:NOMATCH") #! Record("CPIC:CP$(CP)2:2391:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)2:2391:CHFAULT") #! Record("CPIC:CP$(CP)2:2391:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)2:2391:MANPOS_RQST") #! Record("CPIC:CP$(CP)2:2391:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)2:2391:MODE_STATUS") #! Record("CPIC:CP$(CP)2:2391:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)2:2391:INTERLOCKED") #! Record("CPIC:CP$(CP)2:2391:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)2:2391:INTERLOCK") #! Record("CPIC:CP$(CP)2:2391:IVAL",2641,2312,0,1,"CPIC:CP$(CP)2:2391:IVAL") #! Record("CPIC:CP$(CP)2:2391:SVAL",2820,2312,0,1,"CPIC:CP$(CP)2:2391:SVAL") #! Record("CPIC:CP$(CP)2:2391:MMOD",2102,2506,0,1,"CPIC:CP$(CP)2:2391:MMOD") #! Record("CPIC:CP$(CP)2:2391:SMOD",2282,2506,0,1,"CPIC:CP$(CP)2:2391:SMOD") #! Record("CPIC:CP$(CP)2:2391:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)2:2391:MODE_STRING") #! Record("CPIC:CP$(CP)2:2391:PMOD",1922,2506,0,1,"CPIC:CP$(CP)2:2391:PMOD") #! Record("CPIC:CP$(CP)2:2391:IMOD",3020,2506,0,1,"CPIC:CP$(CP)2:2391:IMOD") #! Record("CPIC:CP$(CP)2:2391:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)2:2391:ACTUATOR") #! Record("CPIC:CP$(CP)2:2391:PVAL",3000,2312,0,1,"CPIC:CP$(CP)2:2391:PVAL") #! Record("CPIC:CP$(CP)2:2391:CMD",3021,2112,0,1,"CPIC:CP$(CP)2:2391:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2391 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CTIC:CP$(CP)2:2392:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2392:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CTIC:CP$(CP)2:2392:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392.CVAL") field(PREC, "2") field(EGU, "K") field(ADEL, ".01") } record(ao, "CTIC:CP$(CP)2:2392:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2392:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2392:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2392:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2392:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2392:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2392:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2392:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CTIC:CP$(CP)2:2392:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2392:SP_RQST") { field(DESC, "C$(CP)TIC22392 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392_OVH.SP_Rqst") field(PREC, "2") field(EGU, "K") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CTIC:CP$(CP)2:2392:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CTIC:CP$(CP)2:2392:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)TIC22392") } record(ao, "CTIC:CP$(CP)2:2392:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CTIC:CP$(CP)2:2392:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CTIC:CP$(CP)2:2392:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CTIC:CP$(CP)2:2392:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CTIC:CP$(CP)2:2392:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CTIC:CP$(CP)2:2392:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2392:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CTIC:CP$(CP)2:2392:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CTIC:CP$(CP)2:2392:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CTIC:CP$(CP)2:2392:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CTIC:CP$(CP)2:2392:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CTIC:CP$(CP)2:2392:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CTIC:CP$(CP)2:2392:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392_OVH.Mode_String") } record(bi, "CTIC:CP$(CP)2:2392:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CTIC:CP$(CP)2:2392:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CTIC:CP$(CP)2:2392:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22392") } record(ai, "CTIC:CP$(CP)2:2392:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CTIC:CP$(CP)2:2392:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CTIC:CP$(CP)2:2392:ORBV",2100,2312,0,1,"CTIC:CP$(CP)2:2392:ORBV") #! Record("CTIC:CP$(CP)2:2392:OVAL",2280,2312,0,1,"CTIC:CP$(CP)2:2392:OVAL") #! Record("CTIC:CP$(CP)2:2392:CVAL",2460,2312,0,1,"CTIC:CP$(CP)2:2392:CVAL") #! Record("CTIC:CP$(CP)2:2392:MAX",2122,1932,0,1,"CTIC:CP$(CP)2:2392:MAX") #! Record("CTIC:CP$(CP)2:2392:DMIN",2300,1932,0,1,"CTIC:CP$(CP)2:2392:DMIN") #! Record("CTIC:CP$(CP)2:2392:DMAX",2479,1932,0,1,"CTIC:CP$(CP)2:2392:DMAX") #! Record("CTIC:CP$(CP)2:2392:MODE_RQST",1760,2112,0,1,"CTIC:CP$(CP)2:2392:MODE_RQST") #! Record("CTIC:CP$(CP)2:2392:MDT",2120,2112,0,1,"CTIC:CP$(CP)2:2392:MDT") #! Record("CTIC:CP$(CP)2:2392:KP",2300,2106,0,1,"CTIC:CP$(CP)2:2392:KP") #! Record("CTIC:CP$(CP)2:2392:KI",2480,2106,0,1,"CTIC:CP$(CP)2:2392:KI") #! Record("CTIC:CP$(CP)2:2392:KD",2660,2106,0,1,"CTIC:CP$(CP)2:2392:KD") #! Record("CTIC:CP$(CP)2:2392:S",2840,2120,0,1,"CTIC:CP$(CP)2:2392:S") #! Record("CTIC:CP$(CP)2:2392:SP_RQST",1760,1932,0,1,"CTIC:CP$(CP)2:2392:SP_RQST") #! Record("CTIC:CP$(CP)2:2392:MIN",1945,1932,0,1,"CTIC:CP$(CP)2:2392:MIN") #! Record("CTIC:CP$(CP)2:2392:PIDTAG",1740,2462,0,1,"CTIC:CP$(CP)2:2392:PIDTAG") #! Record("CTIC:CP$(CP)2:2392:PEVAL",2660,1932,0,1,"CTIC:CP$(CP)2:2392:PEVAL") #! Record("CTIC:CP$(CP)2:2392:FSB",2840,1932,0,1,"CTIC:CP$(CP)2:2392:FSB") #! Record("CTIC:CP$(CP)2:2392:NOMATCH",2640,2506,0,1,"CTIC:CP$(CP)2:2392:NOMATCH") #! Record("CTIC:CP$(CP)2:2392:CHFAULT",2820,2506,0,1,"CTIC:CP$(CP)2:2392:CHFAULT") #! Record("CTIC:CP$(CP)2:2392:MANPOS_RQST",1940,2112,0,1,"CTIC:CP$(CP)2:2392:MANPOS_RQST") #! Record("CTIC:CP$(CP)2:2392:MODE_STATUS",1740,2639,0,1,"CTIC:CP$(CP)2:2392:MODE_STATUS") #! Record("CTIC:CP$(CP)2:2392:INTERLOCKED",2460,2686,0,0,"CTIC:CP$(CP)2:2392:INTERLOCKED") #! Record("CTIC:CP$(CP)2:2392:INTERLOCK",2460,2506,0,0,"CTIC:CP$(CP)2:2392:INTERLOCK") #! Record("CTIC:CP$(CP)2:2392:IVAL",2641,2312,0,1,"CTIC:CP$(CP)2:2392:IVAL") #! Record("CTIC:CP$(CP)2:2392:SVAL",2820,2312,0,1,"CTIC:CP$(CP)2:2392:SVAL") #! Record("CTIC:CP$(CP)2:2392:MMOD",2102,2506,0,1,"CTIC:CP$(CP)2:2392:MMOD") #! Record("CTIC:CP$(CP)2:2392:SMOD",2282,2506,0,1,"CTIC:CP$(CP)2:2392:SMOD") #! Record("CTIC:CP$(CP)2:2392:MODE_STRING",1740,2314,0,1,"CTIC:CP$(CP)2:2392:MODE_STRING") #! Record("CTIC:CP$(CP)2:2392:PMOD",1922,2506,0,1,"CTIC:CP$(CP)2:2392:PMOD") #! Record("CTIC:CP$(CP)2:2392:IMOD",3020,2506,0,1,"CTIC:CP$(CP)2:2392:IMOD") #! Record("CTIC:CP$(CP)2:2392:ACTUATOR",1920,2322,0,1,"CTIC:CP$(CP)2:2392:ACTUATOR") #! Record("CTIC:CP$(CP)2:2392:PVAL",3000,2312,0,1,"CTIC:CP$(CP)2:2392:PVAL") #! Record("CTIC:CP$(CP)2:2392:CMD",3021,2112,0,1,"CTIC:CP$(CP)2:2392:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCTIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2392 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)2:2392:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2392:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2392:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)2:2392:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2392:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2392:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2392:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2392:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2392:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2392:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2392:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)2:2392:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2392:SP_RQST") { field(DESC, "C$(CP)PIC22392 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2392:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)2:2392:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC22392") } record(ao, "CPIC:CP$(CP)2:2392:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2392:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)2:2392:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)2:2392:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)2:2392:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)2:2392:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2392:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2392:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)2:2392:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)2:2392:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)2:2392:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)2:2392:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)2:2392:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)2:2392:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)2:2392:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)2:2392:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22392A") } record(ai, "CPIC:CP$(CP)2:2392:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22392A.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)2:2392:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22392A.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)2:2392:ORBV",2100,2312,0,1,"CPIC:CP$(CP)2:2392:ORBV") #! Record("CPIC:CP$(CP)2:2392:OVAL",2280,2312,0,1,"CPIC:CP$(CP)2:2392:OVAL") #! Record("CPIC:CP$(CP)2:2392:CVAL",2460,2312,0,1,"CPIC:CP$(CP)2:2392:CVAL") #! Record("CPIC:CP$(CP)2:2392:MAX",2122,1932,0,1,"CPIC:CP$(CP)2:2392:MAX") #! Record("CPIC:CP$(CP)2:2392:DMIN",2300,1932,0,1,"CPIC:CP$(CP)2:2392:DMIN") #! Record("CPIC:CP$(CP)2:2392:DMAX",2479,1932,0,1,"CPIC:CP$(CP)2:2392:DMAX") #! Record("CPIC:CP$(CP)2:2392:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)2:2392:MODE_RQST") #! Record("CPIC:CP$(CP)2:2392:MDT",2120,2112,0,1,"CPIC:CP$(CP)2:2392:MDT") #! Record("CPIC:CP$(CP)2:2392:KP",2300,2106,0,1,"CPIC:CP$(CP)2:2392:KP") #! Record("CPIC:CP$(CP)2:2392:KI",2480,2106,0,1,"CPIC:CP$(CP)2:2392:KI") #! Record("CPIC:CP$(CP)2:2392:KD",2660,2106,0,1,"CPIC:CP$(CP)2:2392:KD") #! Record("CPIC:CP$(CP)2:2392:S",2840,2120,0,1,"CPIC:CP$(CP)2:2392:S") #! Record("CPIC:CP$(CP)2:2392:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)2:2392:SP_RQST") #! Record("CPIC:CP$(CP)2:2392:MIN",1945,1932,0,1,"CPIC:CP$(CP)2:2392:MIN") #! Record("CPIC:CP$(CP)2:2392:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)2:2392:PIDTAG") #! Record("CPIC:CP$(CP)2:2392:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)2:2392:PEVAL") #! Record("CPIC:CP$(CP)2:2392:FSB",2840,1932,0,1,"CPIC:CP$(CP)2:2392:FSB") #! Record("CPIC:CP$(CP)2:2392:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)2:2392:NOMATCH") #! Record("CPIC:CP$(CP)2:2392:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)2:2392:CHFAULT") #! Record("CPIC:CP$(CP)2:2392:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)2:2392:MANPOS_RQST") #! Record("CPIC:CP$(CP)2:2392:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)2:2392:MODE_STATUS") #! Record("CPIC:CP$(CP)2:2392:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)2:2392:INTERLOCKED") #! Record("CPIC:CP$(CP)2:2392:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)2:2392:INTERLOCK") #! Record("CPIC:CP$(CP)2:2392:IVAL",2641,2312,0,1,"CPIC:CP$(CP)2:2392:IVAL") #! Record("CPIC:CP$(CP)2:2392:SVAL",2820,2312,0,1,"CPIC:CP$(CP)2:2392:SVAL") #! Record("CPIC:CP$(CP)2:2392:MMOD",2102,2506,0,1,"CPIC:CP$(CP)2:2392:MMOD") #! Record("CPIC:CP$(CP)2:2392:SMOD",2282,2506,0,1,"CPIC:CP$(CP)2:2392:SMOD") #! Record("CPIC:CP$(CP)2:2392:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)2:2392:MODE_STRING") #! Record("CPIC:CP$(CP)2:2392:PMOD",1922,2506,0,1,"CPIC:CP$(CP)2:2392:PMOD") #! Record("CPIC:CP$(CP)2:2392:IMOD",3020,2506,0,1,"CPIC:CP$(CP)2:2392:IMOD") #! Record("CPIC:CP$(CP)2:2392:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)2:2392:ACTUATOR") #! Record("CPIC:CP$(CP)2:2392:PVAL",3000,2312,0,1,"CPIC:CP$(CP)2:2392:PVAL") #! Record("CPIC:CP$(CP)2:2392:CMD",3021,2112,0,1,"CPIC:CP$(CP)2:2392:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2392 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)2:2393:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2393:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2393:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)2:2393:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2393:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2393:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2393:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2393:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2393:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2393:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2393:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)2:2393:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2393:SP_RQST") { field(DESC, "C$(CP)PIC22393 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2393:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)2:2393:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC22393") } record(ao, "CPIC:CP$(CP)2:2393:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2393:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)2:2393:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)2:2393:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)2:2393:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)2:2393:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2393:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2393:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)2:2393:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)2:2393:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)2:2393:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)2:2393:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)2:2393:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)2:2393:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)2:2393:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)2:2393:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22393") } record(ai, "CPIC:CP$(CP)2:2393:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22393.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)2:2393:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22393.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)2:2393:ORBV",2100,2312,0,1,"CPIC:CP$(CP)2:2393:ORBV") #! Record("CPIC:CP$(CP)2:2393:OVAL",2280,2312,0,1,"CPIC:CP$(CP)2:2393:OVAL") #! Record("CPIC:CP$(CP)2:2393:CVAL",2460,2312,0,1,"CPIC:CP$(CP)2:2393:CVAL") #! Record("CPIC:CP$(CP)2:2393:MAX",2122,1932,0,1,"CPIC:CP$(CP)2:2393:MAX") #! Record("CPIC:CP$(CP)2:2393:DMIN",2300,1932,0,1,"CPIC:CP$(CP)2:2393:DMIN") #! Record("CPIC:CP$(CP)2:2393:DMAX",2479,1932,0,1,"CPIC:CP$(CP)2:2393:DMAX") #! Record("CPIC:CP$(CP)2:2393:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)2:2393:MODE_RQST") #! Record("CPIC:CP$(CP)2:2393:MDT",2120,2112,0,1,"CPIC:CP$(CP)2:2393:MDT") #! Record("CPIC:CP$(CP)2:2393:KP",2300,2106,0,1,"CPIC:CP$(CP)2:2393:KP") #! Record("CPIC:CP$(CP)2:2393:KI",2480,2106,0,1,"CPIC:CP$(CP)2:2393:KI") #! Record("CPIC:CP$(CP)2:2393:KD",2660,2106,0,1,"CPIC:CP$(CP)2:2393:KD") #! Record("CPIC:CP$(CP)2:2393:S",2840,2120,0,1,"CPIC:CP$(CP)2:2393:S") #! Record("CPIC:CP$(CP)2:2393:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)2:2393:SP_RQST") #! Record("CPIC:CP$(CP)2:2393:MIN",1945,1932,0,1,"CPIC:CP$(CP)2:2393:MIN") #! Record("CPIC:CP$(CP)2:2393:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)2:2393:PIDTAG") #! Record("CPIC:CP$(CP)2:2393:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)2:2393:PEVAL") #! Record("CPIC:CP$(CP)2:2393:FSB",2840,1932,0,1,"CPIC:CP$(CP)2:2393:FSB") #! Record("CPIC:CP$(CP)2:2393:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)2:2393:NOMATCH") #! Record("CPIC:CP$(CP)2:2393:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)2:2393:CHFAULT") #! Record("CPIC:CP$(CP)2:2393:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)2:2393:MANPOS_RQST") #! Record("CPIC:CP$(CP)2:2393:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)2:2393:MODE_STATUS") #! Record("CPIC:CP$(CP)2:2393:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)2:2393:INTERLOCKED") #! Record("CPIC:CP$(CP)2:2393:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)2:2393:INTERLOCK") #! Record("CPIC:CP$(CP)2:2393:IVAL",2641,2312,0,1,"CPIC:CP$(CP)2:2393:IVAL") #! Record("CPIC:CP$(CP)2:2393:SVAL",2820,2312,0,1,"CPIC:CP$(CP)2:2393:SVAL") #! Record("CPIC:CP$(CP)2:2393:MMOD",2102,2506,0,1,"CPIC:CP$(CP)2:2393:MMOD") #! Record("CPIC:CP$(CP)2:2393:SMOD",2282,2506,0,1,"CPIC:CP$(CP)2:2393:SMOD") #! Record("CPIC:CP$(CP)2:2393:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)2:2393:MODE_STRING") #! Record("CPIC:CP$(CP)2:2393:PMOD",1922,2506,0,1,"CPIC:CP$(CP)2:2393:PMOD") #! Record("CPIC:CP$(CP)2:2393:IMOD",3020,2506,0,1,"CPIC:CP$(CP)2:2393:IMOD") #! Record("CPIC:CP$(CP)2:2393:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)2:2393:ACTUATOR") #! Record("CPIC:CP$(CP)2:2393:PVAL",3000,2312,0,1,"CPIC:CP$(CP)2:2393:PVAL") #! Record("CPIC:CP$(CP)2:2393:CMD",3021,2112,0,1,"CPIC:CP$(CP)2:2393:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2393 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)2:2191:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2191:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2191:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)2:2191:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2191:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2191:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2191:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2191:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2191:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2191:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2191:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)2:2191:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2191:SP_RQST") { field(DESC, "C$(CP)PIC22191 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2191:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)2:2191:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC22191") } record(ao, "CPIC:CP$(CP)2:2191:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2191:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)2:2191:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)2:2191:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)2:2191:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)2:2191:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2191:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2191:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)2:2191:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)2:2191:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)2:2191:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)2:2191:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)2:2191:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)2:2191:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)2:2191:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)2:2191:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22191") } record(ai, "CPIC:CP$(CP)2:2191:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22191.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)2:2191:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22191.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)2:2191:ORBV",2100,2312,0,1,"CPIC:CP$(CP)2:2191:ORBV") #! Record("CPIC:CP$(CP)2:2191:OVAL",2280,2312,0,1,"CPIC:CP$(CP)2:2191:OVAL") #! Record("CPIC:CP$(CP)2:2191:CVAL",2460,2312,0,1,"CPIC:CP$(CP)2:2191:CVAL") #! Record("CPIC:CP$(CP)2:2191:MAX",2122,1932,0,1,"CPIC:CP$(CP)2:2191:MAX") #! Record("CPIC:CP$(CP)2:2191:DMIN",2300,1932,0,1,"CPIC:CP$(CP)2:2191:DMIN") #! Record("CPIC:CP$(CP)2:2191:DMAX",2479,1932,0,1,"CPIC:CP$(CP)2:2191:DMAX") #! Record("CPIC:CP$(CP)2:2191:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)2:2191:MODE_RQST") #! Record("CPIC:CP$(CP)2:2191:MDT",2120,2112,0,1,"CPIC:CP$(CP)2:2191:MDT") #! Record("CPIC:CP$(CP)2:2191:KP",2300,2106,0,1,"CPIC:CP$(CP)2:2191:KP") #! Record("CPIC:CP$(CP)2:2191:KI",2480,2106,0,1,"CPIC:CP$(CP)2:2191:KI") #! Record("CPIC:CP$(CP)2:2191:KD",2660,2106,0,1,"CPIC:CP$(CP)2:2191:KD") #! Record("CPIC:CP$(CP)2:2191:S",2840,2120,0,1,"CPIC:CP$(CP)2:2191:S") #! Record("CPIC:CP$(CP)2:2191:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)2:2191:SP_RQST") #! Record("CPIC:CP$(CP)2:2191:MIN",1945,1932,0,1,"CPIC:CP$(CP)2:2191:MIN") #! Record("CPIC:CP$(CP)2:2191:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)2:2191:PIDTAG") #! Record("CPIC:CP$(CP)2:2191:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)2:2191:PEVAL") #! Record("CPIC:CP$(CP)2:2191:FSB",2840,1932,0,1,"CPIC:CP$(CP)2:2191:FSB") #! Record("CPIC:CP$(CP)2:2191:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)2:2191:NOMATCH") #! Record("CPIC:CP$(CP)2:2191:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)2:2191:CHFAULT") #! Record("CPIC:CP$(CP)2:2191:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)2:2191:MANPOS_RQST") #! Record("CPIC:CP$(CP)2:2191:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)2:2191:MODE_STATUS") #! Record("CPIC:CP$(CP)2:2191:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)2:2191:INTERLOCKED") #! Record("CPIC:CP$(CP)2:2191:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)2:2191:INTERLOCK") #! Record("CPIC:CP$(CP)2:2191:IVAL",2641,2312,0,1,"CPIC:CP$(CP)2:2191:IVAL") #! Record("CPIC:CP$(CP)2:2191:SVAL",2820,2312,0,1,"CPIC:CP$(CP)2:2191:SVAL") #! Record("CPIC:CP$(CP)2:2191:MMOD",2102,2506,0,1,"CPIC:CP$(CP)2:2191:MMOD") #! Record("CPIC:CP$(CP)2:2191:SMOD",2282,2506,0,1,"CPIC:CP$(CP)2:2191:SMOD") #! Record("CPIC:CP$(CP)2:2191:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)2:2191:MODE_STRING") #! Record("CPIC:CP$(CP)2:2191:PMOD",1922,2506,0,1,"CPIC:CP$(CP)2:2191:PMOD") #! Record("CPIC:CP$(CP)2:2191:IMOD",3020,2506,0,1,"CPIC:CP$(CP)2:2191:IMOD") #! Record("CPIC:CP$(CP)2:2191:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)2:2191:ACTUATOR") #! Record("CPIC:CP$(CP)2:2191:PVAL",3000,2312,0,1,"CPIC:CP$(CP)2:2191:PVAL") #! Record("CPIC:CP$(CP)2:2191:CMD",3021,2112,0,1,"CPIC:CP$(CP)2:2191:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2191 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)2:2193:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2193:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2193:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)2:2193:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2193:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2193:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2193:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2193:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2193:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2193:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2193:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)2:2193:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2193:SP_RQST") { field(DESC, "C$(CP)PIC22193 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2193:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)2:2193:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC22193") } record(ao, "CPIC:CP$(CP)2:2193:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2193:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)2:2193:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)2:2193:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)2:2193:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)2:2193:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2193:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2193:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)2:2193:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)2:2193:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)2:2193:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)2:2193:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)2:2193:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)2:2193:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)2:2193:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)2:2193:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22193") } record(ai, "CPIC:CP$(CP)2:2193:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22193.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)2:2193:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22193.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)2:2193:ORBV",2100,2312,0,1,"CPIC:CP$(CP)2:2193:ORBV") #! Record("CPIC:CP$(CP)2:2193:OVAL",2280,2312,0,1,"CPIC:CP$(CP)2:2193:OVAL") #! Record("CPIC:CP$(CP)2:2193:CVAL",2460,2312,0,1,"CPIC:CP$(CP)2:2193:CVAL") #! Record("CPIC:CP$(CP)2:2193:MAX",2122,1932,0,1,"CPIC:CP$(CP)2:2193:MAX") #! Record("CPIC:CP$(CP)2:2193:DMIN",2300,1932,0,1,"CPIC:CP$(CP)2:2193:DMIN") #! Record("CPIC:CP$(CP)2:2193:DMAX",2479,1932,0,1,"CPIC:CP$(CP)2:2193:DMAX") #! Record("CPIC:CP$(CP)2:2193:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)2:2193:MODE_RQST") #! Record("CPIC:CP$(CP)2:2193:MDT",2120,2112,0,1,"CPIC:CP$(CP)2:2193:MDT") #! Record("CPIC:CP$(CP)2:2193:KP",2300,2106,0,1,"CPIC:CP$(CP)2:2193:KP") #! Record("CPIC:CP$(CP)2:2193:KI",2480,2106,0,1,"CPIC:CP$(CP)2:2193:KI") #! Record("CPIC:CP$(CP)2:2193:KD",2660,2106,0,1,"CPIC:CP$(CP)2:2193:KD") #! Record("CPIC:CP$(CP)2:2193:S",2840,2120,0,1,"CPIC:CP$(CP)2:2193:S") #! Record("CPIC:CP$(CP)2:2193:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)2:2193:SP_RQST") #! Record("CPIC:CP$(CP)2:2193:MIN",1945,1932,0,1,"CPIC:CP$(CP)2:2193:MIN") #! Record("CPIC:CP$(CP)2:2193:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)2:2193:PIDTAG") #! Record("CPIC:CP$(CP)2:2193:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)2:2193:PEVAL") #! Record("CPIC:CP$(CP)2:2193:FSB",2840,1932,0,1,"CPIC:CP$(CP)2:2193:FSB") #! Record("CPIC:CP$(CP)2:2193:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)2:2193:NOMATCH") #! Record("CPIC:CP$(CP)2:2193:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)2:2193:CHFAULT") #! Record("CPIC:CP$(CP)2:2193:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)2:2193:MANPOS_RQST") #! Record("CPIC:CP$(CP)2:2193:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)2:2193:MODE_STATUS") #! Record("CPIC:CP$(CP)2:2193:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)2:2193:INTERLOCKED") #! Record("CPIC:CP$(CP)2:2193:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)2:2193:INTERLOCK") #! Record("CPIC:CP$(CP)2:2193:IVAL",2641,2312,0,1,"CPIC:CP$(CP)2:2193:IVAL") #! Record("CPIC:CP$(CP)2:2193:SVAL",2820,2312,0,1,"CPIC:CP$(CP)2:2193:SVAL") #! Record("CPIC:CP$(CP)2:2193:MMOD",2102,2506,0,1,"CPIC:CP$(CP)2:2193:MMOD") #! Record("CPIC:CP$(CP)2:2193:SMOD",2282,2506,0,1,"CPIC:CP$(CP)2:2193:SMOD") #! Record("CPIC:CP$(CP)2:2193:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)2:2193:MODE_STRING") #! Record("CPIC:CP$(CP)2:2193:PMOD",1922,2506,0,1,"CPIC:CP$(CP)2:2193:PMOD") #! Record("CPIC:CP$(CP)2:2193:IMOD",3020,2506,0,1,"CPIC:CP$(CP)2:2193:IMOD") #! Record("CPIC:CP$(CP)2:2193:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)2:2193:ACTUATOR") #! Record("CPIC:CP$(CP)2:2193:PVAL",3000,2312,0,1,"CPIC:CP$(CP)2:2193:PVAL") #! Record("CPIC:CP$(CP)2:2193:CMD",3021,2112,0,1,"CPIC:CP$(CP)2:2193:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2193 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)2:2194:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2194:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)2:2194:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)2:2194:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2194:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2194:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2194:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2194:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2194:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2194:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2194:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)2:2194:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2194:SP_RQST") { field(DESC, "C$(CP)PIC22194 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)2:2194:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)2:2194:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC22194") } record(ao, "CPIC:CP$(CP)2:2194:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)2:2194:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)2:2194:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)2:2194:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)2:2194:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)2:2194:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2194:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)2:2194:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)2:2194:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)2:2194:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)2:2194:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)2:2194:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)2:2194:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)2:2194:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)2:2194:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)2:2194:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22194") } record(ai, "CPIC:CP$(CP)2:2194:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22194.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)2:2194:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22194.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)2:2194:ORBV",2100,2312,0,1,"CPIC:CP$(CP)2:2194:ORBV") #! Record("CPIC:CP$(CP)2:2194:OVAL",2280,2312,0,1,"CPIC:CP$(CP)2:2194:OVAL") #! Record("CPIC:CP$(CP)2:2194:CVAL",2460,2312,0,1,"CPIC:CP$(CP)2:2194:CVAL") #! Record("CPIC:CP$(CP)2:2194:MAX",2122,1932,0,1,"CPIC:CP$(CP)2:2194:MAX") #! Record("CPIC:CP$(CP)2:2194:DMIN",2300,1932,0,1,"CPIC:CP$(CP)2:2194:DMIN") #! Record("CPIC:CP$(CP)2:2194:DMAX",2479,1932,0,1,"CPIC:CP$(CP)2:2194:DMAX") #! Record("CPIC:CP$(CP)2:2194:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)2:2194:MODE_RQST") #! Record("CPIC:CP$(CP)2:2194:MDT",2120,2112,0,1,"CPIC:CP$(CP)2:2194:MDT") #! Record("CPIC:CP$(CP)2:2194:KP",2300,2106,0,1,"CPIC:CP$(CP)2:2194:KP") #! Record("CPIC:CP$(CP)2:2194:KI",2480,2106,0,1,"CPIC:CP$(CP)2:2194:KI") #! Record("CPIC:CP$(CP)2:2194:KD",2660,2106,0,1,"CPIC:CP$(CP)2:2194:KD") #! Record("CPIC:CP$(CP)2:2194:S",2840,2120,0,1,"CPIC:CP$(CP)2:2194:S") #! Record("CPIC:CP$(CP)2:2194:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)2:2194:SP_RQST") #! Record("CPIC:CP$(CP)2:2194:MIN",1945,1932,0,1,"CPIC:CP$(CP)2:2194:MIN") #! Record("CPIC:CP$(CP)2:2194:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)2:2194:PIDTAG") #! Record("CPIC:CP$(CP)2:2194:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)2:2194:PEVAL") #! Record("CPIC:CP$(CP)2:2194:FSB",2840,1932,0,1,"CPIC:CP$(CP)2:2194:FSB") #! Record("CPIC:CP$(CP)2:2194:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)2:2194:NOMATCH") #! Record("CPIC:CP$(CP)2:2194:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)2:2194:CHFAULT") #! Record("CPIC:CP$(CP)2:2194:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)2:2194:MANPOS_RQST") #! Record("CPIC:CP$(CP)2:2194:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)2:2194:MODE_STATUS") #! Record("CPIC:CP$(CP)2:2194:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)2:2194:INTERLOCKED") #! Record("CPIC:CP$(CP)2:2194:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)2:2194:INTERLOCK") #! Record("CPIC:CP$(CP)2:2194:IVAL",2641,2312,0,1,"CPIC:CP$(CP)2:2194:IVAL") #! Record("CPIC:CP$(CP)2:2194:SVAL",2820,2312,0,1,"CPIC:CP$(CP)2:2194:SVAL") #! Record("CPIC:CP$(CP)2:2194:MMOD",2102,2506,0,1,"CPIC:CP$(CP)2:2194:MMOD") #! Record("CPIC:CP$(CP)2:2194:SMOD",2282,2506,0,1,"CPIC:CP$(CP)2:2194:SMOD") #! Record("CPIC:CP$(CP)2:2194:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)2:2194:MODE_STRING") #! Record("CPIC:CP$(CP)2:2194:PMOD",1922,2506,0,1,"CPIC:CP$(CP)2:2194:PMOD") #! Record("CPIC:CP$(CP)2:2194:IMOD",3020,2506,0,1,"CPIC:CP$(CP)2:2194:IMOD") #! Record("CPIC:CP$(CP)2:2194:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)2:2194:ACTUATOR") #! Record("CPIC:CP$(CP)2:2194:PVAL",3000,2312,0,1,"CPIC:CP$(CP)2:2194:PVAL") #! Record("CPIC:CP$(CP)2:2194:CMD",3021,2112,0,1,"CPIC:CP$(CP)2:2194:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2194 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CLIC:CP$(CP)2:2195:A:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CLIC:CP$(CP)2:2195:A:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CLIC:CP$(CP)2:2195:A:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195.CVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ao, "CLIC:CP$(CP)2:2195:A:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:A:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:A:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CLIC:CP$(CP)2:2195:A:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:A:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:A:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:A:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:A:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CLIC:CP$(CP)2:2195:A:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:A:SP_RQST") { field(DESC, "C$(CP)LIC22195A PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195_OVH.SP_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:A:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CLIC:CP$(CP)2:2195:A:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)LIC22195A") } record(ao, "CLIC:CP$(CP)2:2195:A:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CLIC:CP$(CP)2:2195:A:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CLIC:CP$(CP)2:2195:A:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CLIC:CP$(CP)2:2195:A:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CLIC:CP$(CP)2:2195:A:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CLIC:CP$(CP)2:2195:A:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CLIC:CP$(CP)2:2195:A:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CLIC:CP$(CP)2:2195:A:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CLIC:CP$(CP)2:2195:A:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CLIC:CP$(CP)2:2195:A:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CLIC:CP$(CP)2:2195:A:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CLIC:CP$(CP)2:2195:A:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CLIC:CP$(CP)2:2195:A:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195_OVH.Mode_String") } record(bi, "CLIC:CP$(CP)2:2195:A:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CLIC:CP$(CP)2:2195:A:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CLIC:CP$(CP)2:2195:A:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV22195") } record(ai, "CLIC:CP$(CP)2:2195:A:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV22195.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CLIC:CP$(CP)2:2195:A:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV22195.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CLIC:CP$(CP)2:2195:A:ORBV",2100,2312,0,1,"CLIC:CP$(CP)2:2195:A:ORBV") #! Record("CLIC:CP$(CP)2:2195:A:OVAL",2280,2312,0,1,"CLIC:CP$(CP)2:2195:A:OVAL") #! Record("CLIC:CP$(CP)2:2195:A:CVAL",2460,2312,0,1,"CLIC:CP$(CP)2:2195:A:CVAL") #! Record("CLIC:CP$(CP)2:2195:A:MAX",2122,1932,0,1,"CLIC:CP$(CP)2:2195:A:MAX") #! Record("CLIC:CP$(CP)2:2195:A:DMIN",2300,1932,0,1,"CLIC:CP$(CP)2:2195:A:DMIN") #! Record("CLIC:CP$(CP)2:2195:A:DMAX",2479,1932,0,1,"CLIC:CP$(CP)2:2195:A:DMAX") #! Record("CLIC:CP$(CP)2:2195:A:MODE_RQST",1760,2112,0,1,"CLIC:CP$(CP)2:2195:A:MODE_RQST") #! Record("CLIC:CP$(CP)2:2195:A:MDT",2120,2112,0,1,"CLIC:CP$(CP)2:2195:A:MDT") #! Record("CLIC:CP$(CP)2:2195:A:KP",2300,2106,0,1,"CLIC:CP$(CP)2:2195:A:KP") #! Record("CLIC:CP$(CP)2:2195:A:KI",2480,2106,0,1,"CLIC:CP$(CP)2:2195:A:KI") #! Record("CLIC:CP$(CP)2:2195:A:KD",2660,2106,0,1,"CLIC:CP$(CP)2:2195:A:KD") #! Record("CLIC:CP$(CP)2:2195:A:S",2840,2120,0,1,"CLIC:CP$(CP)2:2195:A:S") #! Record("CLIC:CP$(CP)2:2195:A:SP_RQST",1760,1932,0,1,"CLIC:CP$(CP)2:2195:A:SP_RQST") #! Record("CLIC:CP$(CP)2:2195:A:MIN",1945,1932,0,1,"CLIC:CP$(CP)2:2195:A:MIN") #! Record("CLIC:CP$(CP)2:2195:A:PIDTAG",1740,2462,0,1,"CLIC:CP$(CP)2:2195:A:PIDTAG") #! Record("CLIC:CP$(CP)2:2195:A:PEVAL",2660,1932,0,1,"CLIC:CP$(CP)2:2195:A:PEVAL") #! Record("CLIC:CP$(CP)2:2195:A:FSB",2840,1932,0,1,"CLIC:CP$(CP)2:2195:A:FSB") #! Record("CLIC:CP$(CP)2:2195:A:NOMATCH",2640,2506,0,1,"CLIC:CP$(CP)2:2195:A:NOMATCH") #! Record("CLIC:CP$(CP)2:2195:A:CHFAULT",2820,2506,0,1,"CLIC:CP$(CP)2:2195:A:CHFAULT") #! Record("CLIC:CP$(CP)2:2195:A:MANPOS_RQST",1940,2112,0,1,"CLIC:CP$(CP)2:2195:A:MANPOS_RQST") #! Record("CLIC:CP$(CP)2:2195:A:MODE_STATUS",1740,2639,0,1,"CLIC:CP$(CP)2:2195:A:MODE_STATUS") #! Record("CLIC:CP$(CP)2:2195:A:INTERLOCKED",2460,2686,0,0,"CLIC:CP$(CP)2:2195:A:INTERLOCKED") #! Record("CLIC:CP$(CP)2:2195:A:INTERLOCK",2460,2506,0,0,"CLIC:CP$(CP)2:2195:A:INTERLOCK") #! Record("CLIC:CP$(CP)2:2195:A:IVAL",2641,2312,0,1,"CLIC:CP$(CP)2:2195:A:IVAL") #! Record("CLIC:CP$(CP)2:2195:A:SVAL",2820,2312,0,1,"CLIC:CP$(CP)2:2195:A:SVAL") #! Record("CLIC:CP$(CP)2:2195:A:MMOD",2102,2506,0,1,"CLIC:CP$(CP)2:2195:A:MMOD") #! Record("CLIC:CP$(CP)2:2195:A:SMOD",2282,2506,0,1,"CLIC:CP$(CP)2:2195:A:SMOD") #! Record("CLIC:CP$(CP)2:2195:A:MODE_STRING",1740,2314,0,1,"CLIC:CP$(CP)2:2195:A:MODE_STRING") #! Record("CLIC:CP$(CP)2:2195:A:PMOD",1922,2506,0,1,"CLIC:CP$(CP)2:2195:A:PMOD") #! Record("CLIC:CP$(CP)2:2195:A:IMOD",3020,2506,0,1,"CLIC:CP$(CP)2:2195:A:IMOD") #! Record("CLIC:CP$(CP)2:2195:A:ACTUATOR",1920,2322,0,1,"CLIC:CP$(CP)2:2195:A:ACTUATOR") #! Record("CLIC:CP$(CP)2:2195:A:PVAL",3000,2312,0,1,"CLIC:CP$(CP)2:2195:A:PVAL") #! Record("CLIC:CP$(CP)2:2195:A:CMD",3021,2112,0,1,"CLIC:CP$(CP)2:2195:A:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCLIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2195:A location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CLIC:CP$(CP)2:2195:B:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CLIC:CP$(CP)2:2195:B:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CLIC:CP$(CP)2:2195:B:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195.CVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ao, "CLIC:CP$(CP)2:2195:B:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:B:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:B:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CLIC:CP$(CP)2:2195:B:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:B:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:B:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:B:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:B:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CLIC:CP$(CP)2:2195:B:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:B:SP_RQST") { field(DESC, "C$(CP)LIC22195B PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195_OVH.SP_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)2:2195:B:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CLIC:CP$(CP)2:2195:B:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)LIC22195B") } record(ao, "CLIC:CP$(CP)2:2195:B:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CLIC:CP$(CP)2:2195:B:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CLIC:CP$(CP)2:2195:B:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CLIC:CP$(CP)2:2195:B:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CLIC:CP$(CP)2:2195:B:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CLIC:CP$(CP)2:2195:B:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CLIC:CP$(CP)2:2195:B:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CLIC:CP$(CP)2:2195:B:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CLIC:CP$(CP)2:2195:B:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CLIC:CP$(CP)2:2195:B:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CLIC:CP$(CP)2:2195:B:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CLIC:CP$(CP)2:2195:B:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CLIC:CP$(CP)2:2195:B:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195_OVH.Mode_String") } record(bi, "CLIC:CP$(CP)2:2195:B:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CLIC:CP$(CP)2:2195:B:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CLIC:CP$(CP)2:2195:B:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "EHTR22195") } record(ai, "CLIC:CP$(CP)2:2195:B:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR22195.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CLIC:CP$(CP)2:2195:B:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR22195.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CLIC:CP$(CP)2:2195:B:ORBV",2100,2312,0,1,"CLIC:CP$(CP)2:2195:B:ORBV") #! Record("CLIC:CP$(CP)2:2195:B:OVAL",2280,2312,0,1,"CLIC:CP$(CP)2:2195:B:OVAL") #! Record("CLIC:CP$(CP)2:2195:B:CVAL",2460,2312,0,1,"CLIC:CP$(CP)2:2195:B:CVAL") #! Record("CLIC:CP$(CP)2:2195:B:MAX",2122,1932,0,1,"CLIC:CP$(CP)2:2195:B:MAX") #! Record("CLIC:CP$(CP)2:2195:B:DMIN",2300,1932,0,1,"CLIC:CP$(CP)2:2195:B:DMIN") #! Record("CLIC:CP$(CP)2:2195:B:DMAX",2479,1932,0,1,"CLIC:CP$(CP)2:2195:B:DMAX") #! Record("CLIC:CP$(CP)2:2195:B:MODE_RQST",1760,2112,0,1,"CLIC:CP$(CP)2:2195:B:MODE_RQST") #! Record("CLIC:CP$(CP)2:2195:B:MDT",2120,2112,0,1,"CLIC:CP$(CP)2:2195:B:MDT") #! Record("CLIC:CP$(CP)2:2195:B:KP",2300,2106,0,1,"CLIC:CP$(CP)2:2195:B:KP") #! Record("CLIC:CP$(CP)2:2195:B:KI",2480,2106,0,1,"CLIC:CP$(CP)2:2195:B:KI") #! Record("CLIC:CP$(CP)2:2195:B:KD",2660,2106,0,1,"CLIC:CP$(CP)2:2195:B:KD") #! Record("CLIC:CP$(CP)2:2195:B:S",2840,2120,0,1,"CLIC:CP$(CP)2:2195:B:S") #! Record("CLIC:CP$(CP)2:2195:B:SP_RQST",1760,1932,0,1,"CLIC:CP$(CP)2:2195:B:SP_RQST") #! Record("CLIC:CP$(CP)2:2195:B:MIN",1945,1932,0,1,"CLIC:CP$(CP)2:2195:B:MIN") #! Record("CLIC:CP$(CP)2:2195:B:PIDTAG",1740,2462,0,1,"CLIC:CP$(CP)2:2195:B:PIDTAG") #! Record("CLIC:CP$(CP)2:2195:B:PEVAL",2660,1932,0,1,"CLIC:CP$(CP)2:2195:B:PEVAL") #! Record("CLIC:CP$(CP)2:2195:B:FSB",2840,1932,0,1,"CLIC:CP$(CP)2:2195:B:FSB") #! Record("CLIC:CP$(CP)2:2195:B:NOMATCH",2640,2506,0,1,"CLIC:CP$(CP)2:2195:B:NOMATCH") #! Record("CLIC:CP$(CP)2:2195:B:CHFAULT",2820,2506,0,1,"CLIC:CP$(CP)2:2195:B:CHFAULT") #! Record("CLIC:CP$(CP)2:2195:B:MANPOS_RQST",1940,2112,0,1,"CLIC:CP$(CP)2:2195:B:MANPOS_RQST") #! Record("CLIC:CP$(CP)2:2195:B:MODE_STATUS",1740,2639,0,1,"CLIC:CP$(CP)2:2195:B:MODE_STATUS") #! Record("CLIC:CP$(CP)2:2195:B:INTERLOCKED",2460,2686,0,0,"CLIC:CP$(CP)2:2195:B:INTERLOCKED") #! Record("CLIC:CP$(CP)2:2195:B:INTERLOCK",2460,2506,0,0,"CLIC:CP$(CP)2:2195:B:INTERLOCK") #! Record("CLIC:CP$(CP)2:2195:B:IVAL",2641,2312,0,1,"CLIC:CP$(CP)2:2195:B:IVAL") #! Record("CLIC:CP$(CP)2:2195:B:SVAL",2820,2312,0,1,"CLIC:CP$(CP)2:2195:B:SVAL") #! Record("CLIC:CP$(CP)2:2195:B:MMOD",2102,2506,0,1,"CLIC:CP$(CP)2:2195:B:MMOD") #! Record("CLIC:CP$(CP)2:2195:B:SMOD",2282,2506,0,1,"CLIC:CP$(CP)2:2195:B:SMOD") #! Record("CLIC:CP$(CP)2:2195:B:MODE_STRING",1740,2314,0,1,"CLIC:CP$(CP)2:2195:B:MODE_STRING") #! Record("CLIC:CP$(CP)2:2195:B:PMOD",1922,2506,0,1,"CLIC:CP$(CP)2:2195:B:PMOD") #! Record("CLIC:CP$(CP)2:2195:B:IMOD",3020,2506,0,1,"CLIC:CP$(CP)2:2195:B:IMOD") #! Record("CLIC:CP$(CP)2:2195:B:ACTUATOR",1920,2322,0,1,"CLIC:CP$(CP)2:2195:B:ACTUATOR") #! Record("CLIC:CP$(CP)2:2195:B:PVAL",3000,2312,0,1,"CLIC:CP$(CP)2:2195:B:PVAL") #! Record("CLIC:CP$(CP)2:2195:B:CMD",3021,2112,0,1,"CLIC:CP$(CP)2:2195:B:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCLIC is the primary portion of device name\nCP$(CP)2 cryoplant number and area in cryoplant\n2195:B location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CLIC:CP$(CP)3:1000:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CLIC:CP$(CP)3:1000:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CLIC:CP$(CP)3:1000:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000.CVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ao, "CLIC:CP$(CP)3:1000:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)3:1000:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)3:1000:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CLIC:CP$(CP)3:1000:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)3:1000:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)3:1000:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)3:1000:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)3:1000:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CLIC:CP$(CP)3:1000:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)3:1000:SP_RQST") { field(DESC, "C$(CP)LIC31000 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000_OVH.SP_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CLIC:CP$(CP)3:1000:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CLIC:CP$(CP)3:1000:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)LIC31000") } record(ao, "CLIC:CP$(CP)3:1000:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CLIC:CP$(CP)3:1000:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CLIC:CP$(CP)3:1000:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CLIC:CP$(CP)3:1000:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CLIC:CP$(CP)3:1000:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CLIC:CP$(CP)3:1000:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CLIC:CP$(CP)3:1000:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CLIC:CP$(CP)3:1000:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CLIC:CP$(CP)3:1000:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CLIC:CP$(CP)3:1000:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CLIC:CP$(CP)3:1000:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CLIC:CP$(CP)3:1000:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CLIC:CP$(CP)3:1000:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000_OVH.Mode_String") } record(bi, "CLIC:CP$(CP)3:1000:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CLIC:CP$(CP)3:1000:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CLIC:CP$(CP)3:1000:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "EHTR31000") } record(ai, "CLIC:CP$(CP)3:1000:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) EHTR31000.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CLIC:CP$(CP)3:1000:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) EHTR31000.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CLIC:CP$(CP)3:1000:ORBV",2100,2312,0,1,"CLIC:CP$(CP)3:1000:ORBV") #! Record("CLIC:CP$(CP)3:1000:OVAL",2280,2312,0,1,"CLIC:CP$(CP)3:1000:OVAL") #! Record("CLIC:CP$(CP)3:1000:CVAL",2460,2312,0,1,"CLIC:CP$(CP)3:1000:CVAL") #! Record("CLIC:CP$(CP)3:1000:MAX",2122,1932,0,1,"CLIC:CP$(CP)3:1000:MAX") #! Record("CLIC:CP$(CP)3:1000:DMIN",2300,1932,0,1,"CLIC:CP$(CP)3:1000:DMIN") #! Record("CLIC:CP$(CP)3:1000:DMAX",2479,1932,0,1,"CLIC:CP$(CP)3:1000:DMAX") #! Record("CLIC:CP$(CP)3:1000:MODE_RQST",1760,2112,0,1,"CLIC:CP$(CP)3:1000:MODE_RQST") #! Record("CLIC:CP$(CP)3:1000:MDT",2120,2112,0,1,"CLIC:CP$(CP)3:1000:MDT") #! Record("CLIC:CP$(CP)3:1000:KP",2300,2106,0,1,"CLIC:CP$(CP)3:1000:KP") #! Record("CLIC:CP$(CP)3:1000:KI",2480,2106,0,1,"CLIC:CP$(CP)3:1000:KI") #! Record("CLIC:CP$(CP)3:1000:KD",2660,2106,0,1,"CLIC:CP$(CP)3:1000:KD") #! Record("CLIC:CP$(CP)3:1000:S",2840,2120,0,1,"CLIC:CP$(CP)3:1000:S") #! Record("CLIC:CP$(CP)3:1000:SP_RQST",1760,1932,0,1,"CLIC:CP$(CP)3:1000:SP_RQST") #! Record("CLIC:CP$(CP)3:1000:MIN",1945,1932,0,1,"CLIC:CP$(CP)3:1000:MIN") #! Record("CLIC:CP$(CP)3:1000:PIDTAG",1740,2462,0,1,"CLIC:CP$(CP)3:1000:PIDTAG") #! Record("CLIC:CP$(CP)3:1000:PEVAL",2660,1932,0,1,"CLIC:CP$(CP)3:1000:PEVAL") #! Record("CLIC:CP$(CP)3:1000:FSB",2840,1932,0,1,"CLIC:CP$(CP)3:1000:FSB") #! Record("CLIC:CP$(CP)3:1000:NOMATCH",2640,2506,0,1,"CLIC:CP$(CP)3:1000:NOMATCH") #! Record("CLIC:CP$(CP)3:1000:CHFAULT",2820,2506,0,1,"CLIC:CP$(CP)3:1000:CHFAULT") #! Record("CLIC:CP$(CP)3:1000:MANPOS_RQST",1940,2112,0,1,"CLIC:CP$(CP)3:1000:MANPOS_RQST") #! Record("CLIC:CP$(CP)3:1000:MODE_STATUS",1740,2639,0,1,"CLIC:CP$(CP)3:1000:MODE_STATUS") #! Record("CLIC:CP$(CP)3:1000:INTERLOCKED",2460,2686,0,0,"CLIC:CP$(CP)3:1000:INTERLOCKED") #! Record("CLIC:CP$(CP)3:1000:INTERLOCK",2460,2506,0,0,"CLIC:CP$(CP)3:1000:INTERLOCK") #! Record("CLIC:CP$(CP)3:1000:IVAL",2641,2312,0,1,"CLIC:CP$(CP)3:1000:IVAL") #! Record("CLIC:CP$(CP)3:1000:SVAL",2820,2312,0,1,"CLIC:CP$(CP)3:1000:SVAL") #! Record("CLIC:CP$(CP)3:1000:MMOD",2102,2506,0,1,"CLIC:CP$(CP)3:1000:MMOD") #! Record("CLIC:CP$(CP)3:1000:SMOD",2282,2506,0,1,"CLIC:CP$(CP)3:1000:SMOD") #! Record("CLIC:CP$(CP)3:1000:MODE_STRING",1740,2314,0,1,"CLIC:CP$(CP)3:1000:MODE_STRING") #! Record("CLIC:CP$(CP)3:1000:PMOD",1922,2506,0,1,"CLIC:CP$(CP)3:1000:PMOD") #! Record("CLIC:CP$(CP)3:1000:IMOD",3020,2506,0,1,"CLIC:CP$(CP)3:1000:IMOD") #! Record("CLIC:CP$(CP)3:1000:ACTUATOR",1920,2322,0,1,"CLIC:CP$(CP)3:1000:ACTUATOR") #! Record("CLIC:CP$(CP)3:1000:PVAL",3000,2312,0,1,"CLIC:CP$(CP)3:1000:PVAL") #! Record("CLIC:CP$(CP)3:1000:CMD",3021,2112,0,1,"CLIC:CP$(CP)3:1000:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCLIC is the primary portion of device name\nCP$(CP)3 cryoplant number and area in cryoplant\n1000 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoplant.dbd") #! DBDEND record(ai, "CPIC:CP$(CP)3:1020:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)3:1020:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP$(CP)3:1020:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP$(CP)3:1020:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020_OVH.Max_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)3:1020:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)3:1020:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)3:1020:MODE_RQST") { field(DESC, "PID Mode request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020_OVH.Mode_Rqst B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)3:1020:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)3:1020:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)3:1020:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)3:1020:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP$(CP)3:1020:S") { field(DESC, "PID Mode String") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)3:1020:SP_RQST") { field(DESC, "C$(CP)PIC31020 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP$(CP)3:1020:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP$(CP)3:1020:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C$(CP)PIC31020") } record(ao, "CPIC:CP$(CP)3:1020:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP$(CP)3:1020:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020.FSB B 0") field(ZNAM, "Last Cmd Val") field(ONAM, "Fail Safe Val") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP$(CP)3:1020:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020_OVH.NoMatch B 0") field(ZNAM, "match") field(ONAM, "nomatch") } record(bi, "CPIC:CP$(CP)3:1020:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP$(CP)3:1020:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP$(CP)3:1020:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020_OVH.Mode_Status") field(HIHI, "4") field(HIGH, "3") field(HHSV, "MAJOR") field(HSV, "MAJOR") } record(bi, "CPIC:CP$(CP)3:1020:INTERLOCKED") { field(DESC, "PID Valve Interlocked Bit") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020.Interlocked") field(ZNAM, "OK") field(ONAM, "Interlocked") field(OSV, "MAJOR") } record(bi, "CPIC:CP$(CP)3:1020:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020_OVH.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") } record(ai, "CPIC:CP$(CP)3:1020:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP$(CP)3:1020:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP$(CP)3:1020:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP$(CP)3:1020:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP$(CP)3:1020:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020_OVH.Mode_String") } record(bi, "CPIC:CP$(CP)3:1020:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020.pmod") field(ZNAM, "not protector") field(ONAM, "protector") } record(bi, "CPIC:CP$(CP)3:1020:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020.imod") field(ZNAM, "no interlock") field(ONAM, "interlock") } record(stringin, "CPIC:CP$(CP)3:1020:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "PV31020") } record(ai, "CPIC:CP$(CP)3:1020:PVAL") { field(DESC, "PID Protector output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PV31020.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bo, "CPIC:CP$(CP)3:1020:CMD") { field(DESC, "PID on/off cmd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PV31020.CMD B 0") field(ZNAM, "Off") field(ONAM, "On") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } #! Further lines contain data used by VisualDCT #! View(1793,2245,1.0) #! Record("CPIC:CP$(CP)3:1020:ORBV",2100,2312,0,1,"CPIC:CP$(CP)3:1020:ORBV") #! Record("CPIC:CP$(CP)3:1020:OVAL",2280,2312,0,1,"CPIC:CP$(CP)3:1020:OVAL") #! Record("CPIC:CP$(CP)3:1020:CVAL",2460,2312,0,1,"CPIC:CP$(CP)3:1020:CVAL") #! Record("CPIC:CP$(CP)3:1020:MAX",2122,1932,0,1,"CPIC:CP$(CP)3:1020:MAX") #! Record("CPIC:CP$(CP)3:1020:DMIN",2300,1932,0,1,"CPIC:CP$(CP)3:1020:DMIN") #! Record("CPIC:CP$(CP)3:1020:DMAX",2479,1932,0,1,"CPIC:CP$(CP)3:1020:DMAX") #! Record("CPIC:CP$(CP)3:1020:MODE_RQST",1760,2112,0,1,"CPIC:CP$(CP)3:1020:MODE_RQST") #! Record("CPIC:CP$(CP)3:1020:MDT",2120,2112,0,1,"CPIC:CP$(CP)3:1020:MDT") #! Record("CPIC:CP$(CP)3:1020:KP",2300,2106,0,1,"CPIC:CP$(CP)3:1020:KP") #! Record("CPIC:CP$(CP)3:1020:KI",2480,2106,0,1,"CPIC:CP$(CP)3:1020:KI") #! Record("CPIC:CP$(CP)3:1020:KD",2660,2106,0,1,"CPIC:CP$(CP)3:1020:KD") #! Record("CPIC:CP$(CP)3:1020:S",2840,2120,0,1,"CPIC:CP$(CP)3:1020:S") #! Record("CPIC:CP$(CP)3:1020:SP_RQST",1760,1932,0,1,"CPIC:CP$(CP)3:1020:SP_RQST") #! Record("CPIC:CP$(CP)3:1020:MIN",1945,1932,0,1,"CPIC:CP$(CP)3:1020:MIN") #! Record("CPIC:CP$(CP)3:1020:PIDTAG",1740,2462,0,1,"CPIC:CP$(CP)3:1020:PIDTAG") #! Record("CPIC:CP$(CP)3:1020:PEVAL",2660,1932,0,1,"CPIC:CP$(CP)3:1020:PEVAL") #! Record("CPIC:CP$(CP)3:1020:FSB",2840,1932,0,1,"CPIC:CP$(CP)3:1020:FSB") #! Record("CPIC:CP$(CP)3:1020:NOMATCH",2640,2506,0,1,"CPIC:CP$(CP)3:1020:NOMATCH") #! Record("CPIC:CP$(CP)3:1020:CHFAULT",2820,2506,0,1,"CPIC:CP$(CP)3:1020:CHFAULT") #! Record("CPIC:CP$(CP)3:1020:MANPOS_RQST",1940,2112,0,1,"CPIC:CP$(CP)3:1020:MANPOS_RQST") #! Record("CPIC:CP$(CP)3:1020:MODE_STATUS",1740,2639,0,1,"CPIC:CP$(CP)3:1020:MODE_STATUS") #! Record("CPIC:CP$(CP)3:1020:INTERLOCKED",2460,2686,0,0,"CPIC:CP$(CP)3:1020:INTERLOCKED") #! Record("CPIC:CP$(CP)3:1020:INTERLOCK",2460,2506,0,0,"CPIC:CP$(CP)3:1020:INTERLOCK") #! Record("CPIC:CP$(CP)3:1020:IVAL",2641,2312,0,1,"CPIC:CP$(CP)3:1020:IVAL") #! Record("CPIC:CP$(CP)3:1020:SVAL",2820,2312,0,1,"CPIC:CP$(CP)3:1020:SVAL") #! Record("CPIC:CP$(CP)3:1020:MMOD",2102,2506,0,1,"CPIC:CP$(CP)3:1020:MMOD") #! Record("CPIC:CP$(CP)3:1020:SMOD",2282,2506,0,1,"CPIC:CP$(CP)3:1020:SMOD") #! Record("CPIC:CP$(CP)3:1020:MODE_STRING",1740,2314,0,1,"CPIC:CP$(CP)3:1020:MODE_STRING") #! Record("CPIC:CP$(CP)3:1020:PMOD",1922,2506,0,1,"CPIC:CP$(CP)3:1020:PMOD") #! Record("CPIC:CP$(CP)3:1020:IMOD",3020,2506,0,1,"CPIC:CP$(CP)3:1020:IMOD") #! Record("CPIC:CP$(CP)3:1020:ACTUATOR",1920,2322,0,1,"CPIC:CP$(CP)3:1020:ACTUATOR") #! Record("CPIC:CP$(CP)3:1020:PVAL",3000,2312,0,1,"CPIC:CP$(CP)3:1020:PVAL") #! Record("CPIC:CP$(CP)3:1020:CMD",3021,2112,0,1,"CPIC:CP$(CP)3:1020:CMD") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP$(CP)3 cryoplant number and area in cryoplant\n1020 location of device as per P&ID diagram\n% EGU of the I/O value",null)