record(bo, "WCMP:$(AREA):$(LOCA):ALM_RESET") {
  field(DESC, "alarm latch reset")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) Alarm_Reset B 0")
}

record(bo, "WCMP:$(AREA):$(LOCA):RELAY") {
  field(DESC, "wcmp motor ctrl relay")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) SO21X B 0")
  field(ZNAM, "off")
  field(ONAM, "RUN")
}

record(bo, "CMCC:$(AREA):$(LOCA):ALM_DIS") {
  field(DESC, "MCC alarm latch reset")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) MCCALM21X_DIS B 0")
  field(ZNAM, "A")
  field(ONAM, "I")
}

record(bo, "CSV:$(AREA):$(LOCA):UNLOAD") {
  field(DESC, "Compressor Unload Cmd")
  field(DTYP, "EtherIP")
  field(VAL, "1")
  field(OUT, "@$(PLC_NAME) Compressor_DO_Buffer B 2")
  field(ONAM, "Unload")
}

record(bo, "CSV:$(AREA):$(LOCA):LOAD") {
  field(DESC, "Compressor Load Cmd")
  field(DTYP, "EtherIP")
  field(VAL, "1")
  field(OUT, "@$(PLC_NAME) Compressor_DO_Buffer B 1")
  field(ONAM, "Load")
}

record(bo, "WCMP:$(AREA):$(LOCA):WD_TMR_OUT") {
  field(DESC, "Watchdog Tmr Out")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) Watchdog_Timer_out")
}

record(bo, "WCMP:$(AREA):$(LOCA):RESET") {
  field(DESC, "Compressor Reset Rqst")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) Compressor_Reset_X B 0")
}

record(bo, "CPMP:$(AREA):$(LOCA):VFD_CMD") {
  field(DESC, "Oil Pump VFD Cmd")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) OPVFD21X")
  field(ZNAM, "STOP")
  field(ONAM, "RUN")
}

record(ao, "CPMP:$(AREA):$(LOCA):FREQ_REQ") {
  field(DESC, "Oil Pump Freq Request")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) PMP21Xo")
  field(PREC, "2")
  field(EGU, "%")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

#! Further lines contain data used by VisualDCT
#! View(1787,2104,1.0)
#! Record("WCMP:$(AREA):$(LOCA):ALM_RESET",2180,2302,0,1,"WCMP:$(AREA):$(LOCA):ALM_RESET")
#! Record("WCMP:$(AREA):$(LOCA):RELAY",2400,2434,0,1,"WCMP:$(AREA):$(LOCA):RELAY")
#! Record("CMCC:$(AREA):$(LOCA):ALM_DIS",2000,2294,0,1,"CMCC:$(AREA):$(LOCA):ALM_DIS")
#! Record("CSV:$(AREA):$(LOCA):UNLOAD",2580,2294,0,1,"CSV:$(AREA):$(LOCA):UNLOAD")
#! Record("CSV:$(AREA):$(LOCA):LOAD",2400,2294,0,1,"CSV:$(AREA):$(LOCA):LOAD")
#! Record("WCMP:$(AREA):$(LOCA):WD_TMR_OUT",1800,2282,0,1,"WCMP:$(AREA):$(LOCA):WD_TMR_OUT")
#! Record("WCMP:$(AREA):$(LOCA):RESET",2080,2442,0,1,"WCMP:$(AREA):$(LOCA):RESET")
#! Record("CPMP:$(AREA):$(LOCA):VFD_CMD",2580,2434,0,1,"CPMP:$(AREA):$(LOCA):VFD_CMD")
#! Record("CPMP:$(AREA):$(LOCA):FREQ_REQ",2800,2299,0,1,"CPMP:$(AREA):$(LOCA):FREQ_REQ")
#! TextBox(TB0,2320,2200,2700,2160,0,"Dialog",12,1,16777215,"Warm Compressor Miscellaneous outputs\n",null)
#! TextBox(TB4,2480,2240,2660,2280,0,"Dialog",12,1,16777215,"Warm Compressor Load/Unload commands",null)
#! TextBox(TB3,2060,2240,2280,2320,0,"Dialog",12,1,16777215,"Alarm RESETS\nMCC Alarm\nWarm compressor alarms",null)
#! TextBox(TB2,2800,2260,2960,2280,0,"Dialog",12,1,16777215,"Oil Pump Freq Command",null)