#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(ao, "CTP:CP$(CP,undefined)2:1040:LO") {
  field(DESC, "TP21040 Alarm LO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21040_Alarm.Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1040:LOLO") {
  field(DESC, "TP21040 Alarm LOLO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21040_Alarm.Lo_Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1040:HI") {
  field(DESC, "TP21040 Alarm HI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21040_Alarm.Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1040:HIHI") {
  field(DESC, "TP21040 Alarm HIHI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21040_Alarm.Hi_Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1040:LTIME") {
  field(DESC, "TP21040 Alarm L Time")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21040_Alarm.Latch_T_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ai, "CTP:CP$(CP,undefined)2:1040:ALM") {
  field(DESC, "TP21040 Alarm Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) TP21040_Alarm.Status")
  field(HIHI, "4")
  field(LOLO, "0")
  field(HIGH, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV, "MINOR")
  field(LSV, "MINOR")
  field(LOW, "1")
}

record(bi, "CTP:CP$(CP,undefined)2:1040:LATCH") {
  field(DESC, "TP21040 Alarm Latch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) TP21040_Alarm.Latch")
}

#! Further lines contain data used by VisualDCT
#! View(1697,1929,1.0)
#! Record("CTP:CP$(CP,undefined)2:1040:LO",1760,2094,0,1,"CTP:CP$(CP,undefined)2:1040:LO")
#! Record("CTP:CP$(CP,undefined)2:1040:LOLO",1940,2094,0,1,"CTP:CP$(CP,undefined)2:1040:LOLO")
#! Record("CTP:CP$(CP,undefined)2:1040:HI",2120,2094,0,1,"CTP:CP$(CP,undefined)2:1040:HI")
#! Record("CTP:CP$(CP,undefined)2:1040:HIHI",2300,2094,0,1,"CTP:CP$(CP,undefined)2:1040:HIHI")
#! Record("CTP:CP$(CP,undefined)2:1040:LTIME",2480,2094,0,1,"CTP:CP$(CP,undefined)2:1040:LTIME")
#! Record("CTP:CP$(CP,undefined)2:1040:ALM",1940,2243,0,1,"CTP:CP$(CP,undefined)2:1040:ALM")
#! Record("CTP:CP$(CP,undefined)2:1040:LATCH",2140,2254,0,1,"CTP:CP$(CP,undefined)2:1040:LATCH")
#! TextBox(TB0,2000,1940,2460,2060,0,"Dialog",12,1,16777215,"Records for the Compressor Alarms\nCTP is the primary portion of device name\nCP$(CP,undefined)2 area in cryoplant\n1040 compressor number and location of device\n$(PLC_NAME,recursive) cryo plc tag name for plcAdmin, form ex.PLC_CP12_CP14\nTP21040  the P&ID identifier for the device\nTP21040 the plc tag name for the data",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(ao, "CTP:CP$(CP,undefined)2:1000:LO") {
  field(DESC, "TP21000 Alarm LO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21000_Alarm.Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1000:LOLO") {
  field(DESC, "TP21000 Alarm LOLO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21000_Alarm.Lo_Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1000:HI") {
  field(DESC, "TP21000 Alarm HI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21000_Alarm.Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1000:HIHI") {
  field(DESC, "TP21000 Alarm HIHI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21000_Alarm.Hi_Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1000:LTIME") {
  field(DESC, "TP21000 Alarm L Time")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21000_Alarm.Latch_T_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ai, "CTP:CP$(CP,undefined)2:1000:ALM") {
  field(DESC, "TP21000 Alarm Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) TP21000_Alarm.Status")
  field(HIHI, "4")
  field(LOLO, "0")
  field(HIGH, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV, "MINOR")
  field(LSV, "MINOR")
  field(LOW, "1")
}

record(bi, "CTP:CP$(CP,undefined)2:1000:LATCH") {
  field(DESC, "TP21000 Alarm Latch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) TP21000_Alarm.Latch")
}

#! Further lines contain data used by VisualDCT
#! View(1697,1929,1.0)
#! Record("CTP:CP$(CP,undefined)2:1000:LO",1760,2094,0,1,"CTP:CP$(CP,undefined)2:1000:LO")
#! Record("CTP:CP$(CP,undefined)2:1000:LOLO",1940,2094,0,1,"CTP:CP$(CP,undefined)2:1000:LOLO")
#! Record("CTP:CP$(CP,undefined)2:1000:HI",2120,2094,0,1,"CTP:CP$(CP,undefined)2:1000:HI")
#! Record("CTP:CP$(CP,undefined)2:1000:HIHI",2300,2094,0,1,"CTP:CP$(CP,undefined)2:1000:HIHI")
#! Record("CTP:CP$(CP,undefined)2:1000:LTIME",2480,2094,0,1,"CTP:CP$(CP,undefined)2:1000:LTIME")
#! Record("CTP:CP$(CP,undefined)2:1000:ALM",1940,2243,0,1,"CTP:CP$(CP,undefined)2:1000:ALM")
#! Record("CTP:CP$(CP,undefined)2:1000:LATCH",2140,2254,0,1,"CTP:CP$(CP,undefined)2:1000:LATCH")
#! TextBox(TB0,2000,1940,2460,2060,0,"Dialog",12,1,16777215,"Records for the Compressor Alarms\nCTP is the primary portion of device name\nCP$(CP,undefined)2 area in cryoplant\n1000 compressor number and location of device\n$(PLC_NAME,recursive) cryo plc tag name for plcAdmin, form ex.PLC_CP12_CP14\nTP21000  the P&ID identifier for the device\nTP21000 the plc tag name for the data",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(ao, "CTP:CP$(CP,undefined)2:1042:LO") {
  field(DESC, "TP21042 Alarm LO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21042_Alarm.Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1042:LOLO") {
  field(DESC, "TP21042 Alarm LOLO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21042_Alarm.Lo_Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1042:HI") {
  field(DESC, "TP21042 Alarm HI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21042_Alarm.Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1042:HIHI") {
  field(DESC, "TP21042 Alarm HIHI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21042_Alarm.Hi_Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1042:LTIME") {
  field(DESC, "TP21042 Alarm L Time")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21042_Alarm.Latch_T_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ai, "CTP:CP$(CP,undefined)2:1042:ALM") {
  field(DESC, "TP21042 Alarm Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) TP21042_Alarm.Status")
  field(HIHI, "4")
  field(LOLO, "0")
  field(HIGH, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV, "MINOR")
  field(LSV, "MINOR")
  field(LOW, "1")
}

record(bi, "CTP:CP$(CP,undefined)2:1042:LATCH") {
  field(DESC, "TP21042 Alarm Latch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) TP21042_Alarm.Latch")
}

#! Further lines contain data used by VisualDCT
#! View(1697,1929,1.0)
#! Record("CTP:CP$(CP,undefined)2:1042:LO",1760,2094,0,1,"CTP:CP$(CP,undefined)2:1042:LO")
#! Record("CTP:CP$(CP,undefined)2:1042:LOLO",1940,2094,0,1,"CTP:CP$(CP,undefined)2:1042:LOLO")
#! Record("CTP:CP$(CP,undefined)2:1042:HI",2120,2094,0,1,"CTP:CP$(CP,undefined)2:1042:HI")
#! Record("CTP:CP$(CP,undefined)2:1042:HIHI",2300,2094,0,1,"CTP:CP$(CP,undefined)2:1042:HIHI")
#! Record("CTP:CP$(CP,undefined)2:1042:LTIME",2480,2094,0,1,"CTP:CP$(CP,undefined)2:1042:LTIME")
#! Record("CTP:CP$(CP,undefined)2:1042:ALM",1940,2243,0,1,"CTP:CP$(CP,undefined)2:1042:ALM")
#! Record("CTP:CP$(CP,undefined)2:1042:LATCH",2140,2254,0,1,"CTP:CP$(CP,undefined)2:1042:LATCH")
#! TextBox(TB0,2000,1940,2460,2060,0,"Dialog",12,1,16777215,"Records for the Compressor Alarms\nCTP is the primary portion of device name\nCP$(CP,undefined)2 area in cryoplant\n1042 compressor number and location of device\n$(PLC_NAME,recursive) cryo plc tag name for plcAdmin, form ex.PLC_CP12_CP14\nTP21042  the P&ID identifier for the device\nTP21042 the plc tag name for the data",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(ao, "CTP:CP$(CP,undefined)2:1045:LO") {
  field(DESC, "TP21045 Alarm LO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21045_Alarm.Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1045:LOLO") {
  field(DESC, "TP21045 Alarm LOLO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21045_Alarm.Lo_Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1045:HI") {
  field(DESC, "TP21045 Alarm HI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21045_Alarm.Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1045:HIHI") {
  field(DESC, "TP21045 Alarm HIHI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21045_Alarm.Hi_Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1045:LTIME") {
  field(DESC, "TP21045 Alarm L Time")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21045_Alarm.Latch_T_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ai, "CTP:CP$(CP,undefined)2:1045:ALM") {
  field(DESC, "TP21045 Alarm Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) TP21045_Alarm.Status")
  field(HIHI, "4")
  field(LOLO, "0")
  field(HIGH, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV, "MINOR")
  field(LSV, "MINOR")
  field(LOW, "1")
}

record(bi, "CTP:CP$(CP,undefined)2:1045:LATCH") {
  field(DESC, "TP21045 Alarm Latch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) TP21045_Alarm.Latch")
}

#! Further lines contain data used by VisualDCT
#! View(1697,1929,1.0)
#! Record("CTP:CP$(CP,undefined)2:1045:LO",1760,2094,0,1,"CTP:CP$(CP,undefined)2:1045:LO")
#! Record("CTP:CP$(CP,undefined)2:1045:LOLO",1940,2094,0,1,"CTP:CP$(CP,undefined)2:1045:LOLO")
#! Record("CTP:CP$(CP,undefined)2:1045:HI",2120,2094,0,1,"CTP:CP$(CP,undefined)2:1045:HI")
#! Record("CTP:CP$(CP,undefined)2:1045:HIHI",2300,2094,0,1,"CTP:CP$(CP,undefined)2:1045:HIHI")
#! Record("CTP:CP$(CP,undefined)2:1045:LTIME",2480,2094,0,1,"CTP:CP$(CP,undefined)2:1045:LTIME")
#! Record("CTP:CP$(CP,undefined)2:1045:ALM",1940,2243,0,1,"CTP:CP$(CP,undefined)2:1045:ALM")
#! Record("CTP:CP$(CP,undefined)2:1045:LATCH",2140,2254,0,1,"CTP:CP$(CP,undefined)2:1045:LATCH")
#! TextBox(TB0,2000,1940,2460,2060,0,"Dialog",12,1,16777215,"Records for the Compressor Alarms\nCTP is the primary portion of device name\nCP$(CP,undefined)2 area in cryoplant\n1045 compressor number and location of device\n$(PLC_NAME,recursive) cryo plc tag name for plcAdmin, form ex.PLC_CP12_CP14\nTP21045  the P&ID identifier for the device\nTP21045 the plc tag name for the data",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(ao, "CTP:CP$(CP,undefined)2:1025:LO") {
  field(DESC, "TP21025 Alarm LO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21025_Alarm.Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1025:LOLO") {
  field(DESC, "TP21025 Alarm LOLO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21025_Alarm.Lo_Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1025:HI") {
  field(DESC, "TP21025 Alarm HI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21025_Alarm.Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1025:HIHI") {
  field(DESC, "TP21025 Alarm HIHI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21025_Alarm.Hi_Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1025:LTIME") {
  field(DESC, "TP21025 Alarm L Time")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21025_Alarm.Latch_T_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ai, "CTP:CP$(CP,undefined)2:1025:ALM") {
  field(DESC, "TP21025 Alarm Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) TP21025_Alarm.Status")
  field(HIHI, "4")
  field(LOLO, "0")
  field(HIGH, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV, "MINOR")
  field(LSV, "MINOR")
  field(LOW, "1")
}

record(bi, "CTP:CP$(CP,undefined)2:1025:LATCH") {
  field(DESC, "TP21025 Alarm Latch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) TP21025_Alarm.Latch")
}

#! Further lines contain data used by VisualDCT
#! View(1697,1929,1.0)
#! Record("CTP:CP$(CP,undefined)2:1025:LO",1760,2094,0,1,"CTP:CP$(CP,undefined)2:1025:LO")
#! Record("CTP:CP$(CP,undefined)2:1025:LOLO",1940,2094,0,1,"CTP:CP$(CP,undefined)2:1025:LOLO")
#! Record("CTP:CP$(CP,undefined)2:1025:HI",2120,2094,0,1,"CTP:CP$(CP,undefined)2:1025:HI")
#! Record("CTP:CP$(CP,undefined)2:1025:HIHI",2300,2094,0,1,"CTP:CP$(CP,undefined)2:1025:HIHI")
#! Record("CTP:CP$(CP,undefined)2:1025:LTIME",2480,2094,0,1,"CTP:CP$(CP,undefined)2:1025:LTIME")
#! Record("CTP:CP$(CP,undefined)2:1025:ALM",1940,2243,0,1,"CTP:CP$(CP,undefined)2:1025:ALM")
#! Record("CTP:CP$(CP,undefined)2:1025:LATCH",2140,2254,0,1,"CTP:CP$(CP,undefined)2:1025:LATCH")
#! TextBox(TB0,2000,1940,2460,2060,0,"Dialog",12,1,16777215,"Records for the Compressor Alarms\nCTP is the primary portion of device name\nCP$(CP,undefined)2 area in cryoplant\n1025 compressor number and location of device\n$(PLC_NAME,recursive) cryo plc tag name for plcAdmin, form ex.PLC_CP12_CP14\nTP21025  the P&ID identifier for the device\nTP21025 the plc tag name for the data",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(ao, "CTP:CP$(CP,undefined)2:1015:LO") {
  field(DESC, "TP21015 Alarm LO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21015_Alarm.Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1015:LOLO") {
  field(DESC, "TP21015 Alarm LOLO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21015_Alarm.Lo_Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1015:HI") {
  field(DESC, "TP21015 Alarm HI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21015_Alarm.Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1015:HIHI") {
  field(DESC, "TP21015 Alarm HIHI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21015_Alarm.Hi_Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CTP:CP$(CP,undefined)2:1015:LTIME") {
  field(DESC, "TP21015 Alarm L Time")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) TP21015_Alarm.Latch_T_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ai, "CTP:CP$(CP,undefined)2:1015:ALM") {
  field(DESC, "TP21015 Alarm Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) TP21015_Alarm.Status")
  field(HIHI, "4")
  field(LOLO, "0")
  field(HIGH, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV, "MINOR")
  field(LSV, "MINOR")
  field(LOW, "1")
}

record(bi, "CTP:CP$(CP,undefined)2:1015:LATCH") {
  field(DESC, "TP21015 Alarm Latch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) TP21015_Alarm.Latch")
}

#! Further lines contain data used by VisualDCT
#! View(1697,1929,1.0)
#! Record("CTP:CP$(CP,undefined)2:1015:LO",1760,2094,0,1,"CTP:CP$(CP,undefined)2:1015:LO")
#! Record("CTP:CP$(CP,undefined)2:1015:LOLO",1940,2094,0,1,"CTP:CP$(CP,undefined)2:1015:LOLO")
#! Record("CTP:CP$(CP,undefined)2:1015:HI",2120,2094,0,1,"CTP:CP$(CP,undefined)2:1015:HI")
#! Record("CTP:CP$(CP,undefined)2:1015:HIHI",2300,2094,0,1,"CTP:CP$(CP,undefined)2:1015:HIHI")
#! Record("CTP:CP$(CP,undefined)2:1015:LTIME",2480,2094,0,1,"CTP:CP$(CP,undefined)2:1015:LTIME")
#! Record("CTP:CP$(CP,undefined)2:1015:ALM",1940,2243,0,1,"CTP:CP$(CP,undefined)2:1015:ALM")
#! Record("CTP:CP$(CP,undefined)2:1015:LATCH",2140,2254,0,1,"CTP:CP$(CP,undefined)2:1015:LATCH")
#! TextBox(TB0,2000,1940,2460,2060,0,"Dialog",12,1,16777215,"Records for the Compressor Alarms\nCTP is the primary portion of device name\nCP$(CP,undefined)2 area in cryoplant\n1015 compressor number and location of device\n$(PLC_NAME,recursive) cryo plc tag name for plcAdmin, form ex.PLC_CP12_CP14\nTP21015  the P&ID identifier for the device\nTP21015 the plc tag name for the data",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(ao, "CPT:CP$(CP,undefined)2:1040:LO") {
  field(DESC, "PT21040 Alarm LO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21040_Alarm.Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1040:LOLO") {
  field(DESC, "PT21040 Alarm LOLO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21040_Alarm.Lo_Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1040:HI") {
  field(DESC, "PT21040 Alarm HI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21040_Alarm.Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1040:HIHI") {
  field(DESC, "PT21040 Alarm HIHI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21040_Alarm.Hi_Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1040:LTIME") {
  field(DESC, "PT21040 Alarm L Time")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21040_Alarm.Latch_T_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ai, "CPT:CP$(CP,undefined)2:1040:ALM") {
  field(DESC, "PT21040 Alarm Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21040_Alarm.Status")
  field(HIHI, "4")
  field(LOLO, "0")
  field(HIGH, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV, "MINOR")
  field(LSV, "MINOR")
  field(LOW, "1")
}

record(bi, "CPT:CP$(CP,undefined)2:1040:LATCH") {
  field(DESC, "PT21040 Alarm Latch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21040_Alarm.Latch")
}

#! Further lines contain data used by VisualDCT
#! View(1697,1929,1.0)
#! Record("CPT:CP$(CP,undefined)2:1040:LO",1760,2094,0,1,"CPT:CP$(CP,undefined)2:1040:LO")
#! Record("CPT:CP$(CP,undefined)2:1040:LOLO",1940,2094,0,1,"CPT:CP$(CP,undefined)2:1040:LOLO")
#! Record("CPT:CP$(CP,undefined)2:1040:HI",2120,2094,0,1,"CPT:CP$(CP,undefined)2:1040:HI")
#! Record("CPT:CP$(CP,undefined)2:1040:HIHI",2300,2094,0,1,"CPT:CP$(CP,undefined)2:1040:HIHI")
#! Record("CPT:CP$(CP,undefined)2:1040:LTIME",2480,2094,0,1,"CPT:CP$(CP,undefined)2:1040:LTIME")
#! Record("CPT:CP$(CP,undefined)2:1040:ALM",1940,2243,0,1,"CPT:CP$(CP,undefined)2:1040:ALM")
#! Record("CPT:CP$(CP,undefined)2:1040:LATCH",2140,2254,0,1,"CPT:CP$(CP,undefined)2:1040:LATCH")
#! TextBox(TB0,2000,1940,2460,2060,0,"Dialog",12,1,16777215,"Records for the Compressor Alarms\nCPT is the primary portion of device name\nCP$(CP,undefined)2 area in cryoplant\n1040 compressor number and location of device\n$(PLC_NAME,recursive) cryo plc tag name for plcAdmin, form ex.PLC_CP12_CP14\nPT21040  the P&ID identifier for the device\nPT21040 the plc tag name for the data",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(ao, "CPT:CP$(CP,undefined)2:1030:LO") {
  field(DESC, "PT21030 Alarm LO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21030_Alarm.Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1030:LOLO") {
  field(DESC, "PT21030 Alarm LOLO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21030_Alarm.Lo_Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1030:HI") {
  field(DESC, "PT21030 Alarm HI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21030_Alarm.Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1030:HIHI") {
  field(DESC, "PT21030 Alarm HIHI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21030_Alarm.Hi_Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1030:LTIME") {
  field(DESC, "PT21030 Alarm L Time")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21030_Alarm.Latch_T_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ai, "CPT:CP$(CP,undefined)2:1030:ALM") {
  field(DESC, "PT21030 Alarm Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21030_Alarm.Status")
  field(HIHI, "4")
  field(LOLO, "0")
  field(HIGH, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV, "MINOR")
  field(LSV, "MINOR")
  field(LOW, "1")
}

record(bi, "CPT:CP$(CP,undefined)2:1030:LATCH") {
  field(DESC, "PT21030 Alarm Latch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21030_Alarm.Latch")
}

#! Further lines contain data used by VisualDCT
#! View(1697,1929,1.0)
#! Record("CPT:CP$(CP,undefined)2:1030:LO",1760,2094,0,1,"CPT:CP$(CP,undefined)2:1030:LO")
#! Record("CPT:CP$(CP,undefined)2:1030:LOLO",1940,2094,0,1,"CPT:CP$(CP,undefined)2:1030:LOLO")
#! Record("CPT:CP$(CP,undefined)2:1030:HI",2120,2094,0,1,"CPT:CP$(CP,undefined)2:1030:HI")
#! Record("CPT:CP$(CP,undefined)2:1030:HIHI",2300,2094,0,1,"CPT:CP$(CP,undefined)2:1030:HIHI")
#! Record("CPT:CP$(CP,undefined)2:1030:LTIME",2480,2094,0,1,"CPT:CP$(CP,undefined)2:1030:LTIME")
#! Record("CPT:CP$(CP,undefined)2:1030:ALM",1940,2243,0,1,"CPT:CP$(CP,undefined)2:1030:ALM")
#! Record("CPT:CP$(CP,undefined)2:1030:LATCH",2140,2254,0,1,"CPT:CP$(CP,undefined)2:1030:LATCH")
#! TextBox(TB0,2000,1940,2460,2060,0,"Dialog",12,1,16777215,"Records for the Compressor Alarms\nCPT is the primary portion of device name\nCP$(CP,undefined)2 area in cryoplant\n1030 compressor number and location of device\n$(PLC_NAME,recursive) cryo plc tag name for plcAdmin, form ex.PLC_CP12_CP14\nPT21030  the P&ID identifier for the device\nPT21030 the plc tag name for the data",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(ao, "CPT:CP$(CP,undefined)2:1032:LO") {
  field(DESC, "PT21032 Alarm LO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21032_Alarm.Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1032:LOLO") {
  field(DESC, "PT21032 Alarm LOLO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21032_Alarm.Lo_Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1032:HI") {
  field(DESC, "PT21032 Alarm HI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21032_Alarm.Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1032:HIHI") {
  field(DESC, "PT21032 Alarm HIHI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21032_Alarm.Hi_Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1032:LTIME") {
  field(DESC, "PT21032 Alarm L Time")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21032_Alarm.Latch_T_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ai, "CPT:CP$(CP,undefined)2:1032:ALM") {
  field(DESC, "PT21032 Alarm Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21032_Alarm.Status")
  field(HIHI, "4")
  field(LOLO, "0")
  field(HIGH, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV, "MINOR")
  field(LSV, "MINOR")
  field(LOW, "1")
}

record(bi, "CPT:CP$(CP,undefined)2:1032:LATCH") {
  field(DESC, "PT21032 Alarm Latch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21032_Alarm.Latch")
}

#! Further lines contain data used by VisualDCT
#! View(1697,1929,1.0)
#! Record("CPT:CP$(CP,undefined)2:1032:LO",1760,2094,0,1,"CPT:CP$(CP,undefined)2:1032:LO")
#! Record("CPT:CP$(CP,undefined)2:1032:LOLO",1940,2094,0,1,"CPT:CP$(CP,undefined)2:1032:LOLO")
#! Record("CPT:CP$(CP,undefined)2:1032:HI",2120,2094,0,1,"CPT:CP$(CP,undefined)2:1032:HI")
#! Record("CPT:CP$(CP,undefined)2:1032:HIHI",2300,2094,0,1,"CPT:CP$(CP,undefined)2:1032:HIHI")
#! Record("CPT:CP$(CP,undefined)2:1032:LTIME",2480,2094,0,1,"CPT:CP$(CP,undefined)2:1032:LTIME")
#! Record("CPT:CP$(CP,undefined)2:1032:ALM",1940,2243,0,1,"CPT:CP$(CP,undefined)2:1032:ALM")
#! Record("CPT:CP$(CP,undefined)2:1032:LATCH",2140,2254,0,1,"CPT:CP$(CP,undefined)2:1032:LATCH")
#! TextBox(TB0,2000,1940,2460,2060,0,"Dialog",12,1,16777215,"Records for the Compressor Alarms\nCPT is the primary portion of device name\nCP$(CP,undefined)2 area in cryoplant\n1032 compressor number and location of device\n$(PLC_NAME,recursive) cryo plc tag name for plcAdmin, form ex.PLC_CP12_CP14\nPT21032  the P&ID identifier for the device\nPT21032 the plc tag name for the data",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(ao, "CPT:CP$(CP,undefined)2:1012:LO") {
  field(DESC, "PT21012 Alarm LO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21012_Alarm.Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1012:LOLO") {
  field(DESC, "PT21012 Alarm LOLO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21012_Alarm.Lo_Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1012:HI") {
  field(DESC, "PT21012 Alarm HI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21012_Alarm.Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1012:HIHI") {
  field(DESC, "PT21012 Alarm HIHI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21012_Alarm.Hi_Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1012:LTIME") {
  field(DESC, "PT21012 Alarm L Time")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21012_Alarm.Latch_T_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ai, "CPT:CP$(CP,undefined)2:1012:ALM") {
  field(DESC, "PT21012 Alarm Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21012_Alarm.Status")
  field(HIHI, "4")
  field(LOLO, "0")
  field(HIGH, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV, "MINOR")
  field(LSV, "MINOR")
  field(LOW, "1")
}

record(bi, "CPT:CP$(CP,undefined)2:1012:LATCH") {
  field(DESC, "PT21012 Alarm Latch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21012_Alarm.Latch")
}

#! Further lines contain data used by VisualDCT
#! View(1697,1929,1.0)
#! Record("CPT:CP$(CP,undefined)2:1012:LO",1760,2094,0,1,"CPT:CP$(CP,undefined)2:1012:LO")
#! Record("CPT:CP$(CP,undefined)2:1012:LOLO",1940,2094,0,1,"CPT:CP$(CP,undefined)2:1012:LOLO")
#! Record("CPT:CP$(CP,undefined)2:1012:HI",2120,2094,0,1,"CPT:CP$(CP,undefined)2:1012:HI")
#! Record("CPT:CP$(CP,undefined)2:1012:HIHI",2300,2094,0,1,"CPT:CP$(CP,undefined)2:1012:HIHI")
#! Record("CPT:CP$(CP,undefined)2:1012:LTIME",2480,2094,0,1,"CPT:CP$(CP,undefined)2:1012:LTIME")
#! Record("CPT:CP$(CP,undefined)2:1012:ALM",1940,2243,0,1,"CPT:CP$(CP,undefined)2:1012:ALM")
#! Record("CPT:CP$(CP,undefined)2:1012:LATCH",2140,2254,0,1,"CPT:CP$(CP,undefined)2:1012:LATCH")
#! TextBox(TB0,2000,1940,2460,2060,0,"Dialog",12,1,16777215,"Records for the Compressor Alarms\nCPT is the primary portion of device name\nCP$(CP,undefined)2 area in cryoplant\n1012 compressor number and location of device\n$(PLC_NAME,recursive) cryo plc tag name for plcAdmin, form ex.PLC_CP12_CP14\nPT21012  the P&ID identifier for the device\nPT21012 the plc tag name for the data",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(ao, "CPT:CP$(CP,undefined)2:1022:LO") {
  field(DESC, "PT21022 Alarm LO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21022_Alarm.Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1022:LOLO") {
  field(DESC, "PT21022 Alarm LOLO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21022_Alarm.Lo_Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1022:HI") {
  field(DESC, "PT21022 Alarm HI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21022_Alarm.Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1022:HIHI") {
  field(DESC, "PT21022 Alarm HIHI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21022_Alarm.Hi_Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1022:LTIME") {
  field(DESC, "PT21022 Alarm L Time")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21022_Alarm.Latch_T_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ai, "CPT:CP$(CP,undefined)2:1022:ALM") {
  field(DESC, "PT21022 Alarm Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21022_Alarm.Status")
  field(HIHI, "4")
  field(LOLO, "0")
  field(HIGH, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV, "MINOR")
  field(LSV, "MINOR")
  field(LOW, "1")
}

record(bi, "CPT:CP$(CP,undefined)2:1022:LATCH") {
  field(DESC, "PT21022 Alarm Latch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21022_Alarm.Latch")
}

#! Further lines contain data used by VisualDCT
#! View(1697,1929,1.0)
#! Record("CPT:CP$(CP,undefined)2:1022:LO",1760,2094,0,1,"CPT:CP$(CP,undefined)2:1022:LO")
#! Record("CPT:CP$(CP,undefined)2:1022:LOLO",1940,2094,0,1,"CPT:CP$(CP,undefined)2:1022:LOLO")
#! Record("CPT:CP$(CP,undefined)2:1022:HI",2120,2094,0,1,"CPT:CP$(CP,undefined)2:1022:HI")
#! Record("CPT:CP$(CP,undefined)2:1022:HIHI",2300,2094,0,1,"CPT:CP$(CP,undefined)2:1022:HIHI")
#! Record("CPT:CP$(CP,undefined)2:1022:LTIME",2480,2094,0,1,"CPT:CP$(CP,undefined)2:1022:LTIME")
#! Record("CPT:CP$(CP,undefined)2:1022:ALM",1940,2243,0,1,"CPT:CP$(CP,undefined)2:1022:ALM")
#! Record("CPT:CP$(CP,undefined)2:1022:LATCH",2140,2254,0,1,"CPT:CP$(CP,undefined)2:1022:LATCH")
#! TextBox(TB0,2000,1940,2460,2060,0,"Dialog",12,1,16777215,"Records for the Compressor Alarms\nCPT is the primary portion of device name\nCP$(CP,undefined)2 area in cryoplant\n1022 compressor number and location of device\n$(PLC_NAME,recursive) cryo plc tag name for plcAdmin, form ex.PLC_CP12_CP14\nPT21022  the P&ID identifier for the device\nPT21022 the plc tag name for the data",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(ao, "CPT:CP$(CP,undefined)2:1005:LO") {
  field(DESC, "PT21005 Alarm LO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21005_Alarm.Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1005:LOLO") {
  field(DESC, "PT21005 Alarm LOLO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21005_Alarm.Lo_Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1005:HI") {
  field(DESC, "PT21005 Alarm HI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21005_Alarm.Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1005:HIHI") {
  field(DESC, "PT21005 Alarm HIHI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21005_Alarm.Hi_Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1005:LTIME") {
  field(DESC, "PT21005 Alarm L Time")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21005_Alarm.Latch_T_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ai, "CPT:CP$(CP,undefined)2:1005:ALM") {
  field(DESC, "PT21005 Alarm Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21005_Alarm.Status")
  field(HIHI, "4")
  field(LOLO, "0")
  field(HIGH, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV, "MINOR")
  field(LSV, "MINOR")
  field(LOW, "1")
}

record(bi, "CPT:CP$(CP,undefined)2:1005:LATCH") {
  field(DESC, "PT21005 Alarm Latch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21005_Alarm.Latch")
}

#! Further lines contain data used by VisualDCT
#! View(1697,1929,1.0)
#! Record("CPT:CP$(CP,undefined)2:1005:LO",1760,2094,0,1,"CPT:CP$(CP,undefined)2:1005:LO")
#! Record("CPT:CP$(CP,undefined)2:1005:LOLO",1940,2094,0,1,"CPT:CP$(CP,undefined)2:1005:LOLO")
#! Record("CPT:CP$(CP,undefined)2:1005:HI",2120,2094,0,1,"CPT:CP$(CP,undefined)2:1005:HI")
#! Record("CPT:CP$(CP,undefined)2:1005:HIHI",2300,2094,0,1,"CPT:CP$(CP,undefined)2:1005:HIHI")
#! Record("CPT:CP$(CP,undefined)2:1005:LTIME",2480,2094,0,1,"CPT:CP$(CP,undefined)2:1005:LTIME")
#! Record("CPT:CP$(CP,undefined)2:1005:ALM",1940,2243,0,1,"CPT:CP$(CP,undefined)2:1005:ALM")
#! Record("CPT:CP$(CP,undefined)2:1005:LATCH",2140,2254,0,1,"CPT:CP$(CP,undefined)2:1005:LATCH")
#! TextBox(TB0,2000,1940,2460,2060,0,"Dialog",12,1,16777215,"Records for the Compressor Alarms\nCPT is the primary portion of device name\nCP$(CP,undefined)2 area in cryoplant\n1005 compressor number and location of device\n$(PLC_NAME,recursive) cryo plc tag name for plcAdmin, form ex.PLC_CP12_CP14\nPT21005  the P&ID identifier for the device\nPT21005 the plc tag name for the data",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/cryoControl.dbd")
#! DBDEND


record(ao, "CPT:CP$(CP,undefined)2:1000:LO") {
  field(DESC, "PT21000 Alarm LO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21000_Alarm.Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1000:LOLO") {
  field(DESC, "PT21000 Alarm LOLO")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21000_Alarm.Lo_Lo_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1000:HI") {
  field(DESC, "PT21000 Alarm HI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21000_Alarm.Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1000:HIHI") {
  field(DESC, "PT21000 Alarm HIHI")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21000_Alarm.Hi_Hi_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ao, "CPT:CP$(CP,undefined)2:1000:LTIME") {
  field(DESC, "PT21000 Alarm L Time")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME,recursive) PT21000_Alarm.Latch_T_X")
  field(PREC, "2")
  field(EGU, "%")
}

record(ai, "CPT:CP$(CP,undefined)2:1000:ALM") {
  field(DESC, "PT21000 Alarm Status")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21000_Alarm.Status")
  field(HIHI, "4")
  field(LOLO, "0")
  field(HIGH, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV, "MINOR")
  field(LSV, "MINOR")
  field(LOW, "1")
}

record(bi, "CPT:CP$(CP,undefined)2:1000:LATCH") {
  field(DESC, "PT21000 Alarm Latch")
  field(SCAN, "1 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME,recursive) PT21000_Alarm.Latch")
}

#! Further lines contain data used by VisualDCT
#! View(1697,1929,1.0)
#! Record("CPT:CP$(CP,undefined)2:1000:LO",1760,2094,0,1,"CPT:CP$(CP,undefined)2:1000:LO")
#! Record("CPT:CP$(CP,undefined)2:1000:LOLO",1940,2094,0,1,"CPT:CP$(CP,undefined)2:1000:LOLO")
#! Record("CPT:CP$(CP,undefined)2:1000:HI",2120,2094,0,1,"CPT:CP$(CP,undefined)2:1000:HI")
#! Record("CPT:CP$(CP,undefined)2:1000:HIHI",2300,2094,0,1,"CPT:CP$(CP,undefined)2:1000:HIHI")
#! Record("CPT:CP$(CP,undefined)2:1000:LTIME",2480,2094,0,1,"CPT:CP$(CP,undefined)2:1000:LTIME")
#! Record("CPT:CP$(CP,undefined)2:1000:ALM",1940,2243,0,1,"CPT:CP$(CP,undefined)2:1000:ALM")
#! Record("CPT:CP$(CP,undefined)2:1000:LATCH",2140,2254,0,1,"CPT:CP$(CP,undefined)2:1000:LATCH")
#! TextBox(TB0,2000,1940,2460,2060,0,"Dialog",12,1,16777215,"Records for the Compressor Alarms\nCPT is the primary portion of device name\nCP$(CP,undefined)2 area in cryoplant\n1000 compressor number and location of device\n$(PLC_NAME,recursive) cryo plc tag name for plcAdmin, form ex.PLC_CP12_CP14\nPT21000  the P&ID identifier for the device\nPT21000 the plc tag name for the data",null)