# These are the records that transform tick counts to time in nanoseconds,
# by using the sampling frequency of the ADCs.

# Giving the frequency in Hz, calculate the time in ns between each sample
record (calc, "BLEN:$(AREA):$(POS):$(AMC):SAMP_TIME") {
  field(DESC, "Time between samples in ns")
  field(INPA, "BLEN:$(AREA):$(POS):$(AMC):AmcClkFreq CP")
  field(CALC, "1000000000/(2 * A)")
}