record(sub, "BLEN:LI24:886:AIMAX") { field(INPA, "0") field(INPB, "5462.5") field(INPC, "-0.5") field(INPD, "0.75") field(INPE, "0") field(INPF, "0") field(INPG, "0") field(INPH, "0") field(INPI, "0") field(INPJ, "0") field(INPK, "3") field(INPL, "4") field(SNAM, "fbckSupIpkCalc") field(MDEL, "-1") field(EGU, "A") field(TSE, "-2") field(SCAN, "Event") field(EVNT, "124") field(PRIO, "HIGH") field(FLNK, "BLEN:LI24:886:EFAIMAX") } record(sub, "BLEN:LI24:886:BIMAX") { field(INPA, "0") field(INPB, "5462.5") field(INPC, "-0.5") field(INPD, "0.75") field(INPE, "0") field(INPF, "0") field(INPG, "0") field(INPH, "0") field(INPI, "0") field(INPJ, "BLEN:LI24:886:P1FLT1_IN") field(INPK, "3") field(INPL, "5") field(SNAM, "fbckSupIpkCalc") field(MDEL, "-1") field(EGU, "A") field(TSE, "-2") field(SCAN, "Event") field(EVNT, "124") field(PRIO, "HIGH") field(FLNK, "BLEN:LI24:886:EFBIMAX") } record(mbbo, "BLEN:LI24:886:BL21_ACCESS") { field(DESC, "BPM On Line") field(DTYP, "StreamSwitch") # card: set pad to correct enum for this station (src/llrfMacros.h) # signal: 0 means reg bpm data (not cal data) field(OUT, "#C3 S0") field(ZRVL, "1") field(ZRST, "Running") field(ZRSV, "NO_ALARM") field(ONVL, "1") field(ONST, "Maintenance") field(ONSV, "MINOR") field(TWVL, "1") field(TWST, "Test") field(TWSV, "MINOR") field(THVL, "0") field(THST, "OFFLINE") field(THSV, "MAJOR") # set both, rval and val to get it right # regardless of whether devsup does conversion # or not. field(RVAL, "0") field(VAL, "0") field(PINI, "YES") } record(waveform, "BLEN:LI24:886:BL21_WF_CP") { field(DESC, "sums") field(DTYP, "BLM") field(SCAN, "I/O Intr") field(NELM, "4") field(INP, "#C3 S0 @RowMajor") #dbfType in base/include/dbFldTypes.h field(FTVL, "LONG") field(FLNK, "") field(TSE, "-2") field(PRIO, "HIGH") # Measure the effect } record(ai,"BLEN:LI24:886:ARAW") { field(EGU, "") field(DESC,"sum A") field(DTYP,"BLM") field(INP, "#@0 3 0") field(SCAN,"I/O Intr") field(FLNK,"BLEN:LI24:886:EFARAW") # field(PINI,"YES") field(PREC,"3") field(HIGH,"0") field(LOW, "0") field(HIHI,"0") field(LOLO,"0") field(HOPR,"0") field(LOPR,"0") field(HSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HHSV,"NO_ALARM") field(LLSV,"NO_ALARM") field(MDEL,"-1") field(PRIO,"HIGH") field(TSE, "-2") } record(ai,"BLEN:LI24:886:BRAW") { field(EGU, "") field(DESC,"sum B") field(DTYP,"BLM") field(INP, "#@0 3 1") field(SCAN,"I/O Intr") field(FLNK,"BLEN:LI24:886:EFBRAW") # field(PINI,"YES") field(PREC,"3") field(HIGH,"0") field(LOW, "0") field(HIHI,"0") field(LOLO,"0") field(HOPR,"0") field(LOPR,"0") field(HSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HHSV,"NO_ALARM") field(LLSV,"NO_ALARM") field(MDEL,"-1") field(PRIO,"HIGH") field(TSE, "-2") } record(ai,"BLEN:LI24:886:BL21A_SUM") { field(EGU, "") field(DESC,"sum A") field(DTYP,"BLM") field(INP, "#@0 3 0") field(SCAN,"I/O Intr") field(FLNK,"") # field(PINI,"YES") field(PREC,"3") field(HIGH,"0") field(LOW, "0") field(HIHI,"0") field(LOLO,"0") field(HOPR,"0") field(LOPR,"0") field(HSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HHSV,"NO_ALARM") field(LLSV,"NO_ALARM") field(MDEL,"-1") field(PRIO,"HIGH") field(TSE, "-2") } record(ai,"BLEN:LI24:886:BL21B_SUM") { field(EGU, "") field(DESC,"sum B") field(DTYP,"BLM") field(INP, "#@0 3 1") field(SCAN,"I/O Intr") field(FLNK,"") # field(PINI,"YES") field(PREC,"3") field(HIGH,"0") field(LOW, "0") field(HIHI,"0") field(LOLO,"0") field(HOPR,"0") field(LOPR,"0") field(HSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HHSV,"NO_ALARM") field(LLSV,"NO_ALARM") field(MDEL,"-1") field(PRIO,"HIGH") field(TSE, "-2") } record(ai,"BLEN:LI24:886:BL21A_S_SUM") { field(EGU, "") field(DESC,"sum A for display") field(DTYP,"BLM") field(INP, "#@0 3 0") field(SCAN,"I/O Intr") field(FLNK,"") # field(PINI,"YES") field(PREC,"3") field(HIGH,"0") field(LOW, "0") field(HIHI,"0") field(LOLO,"0") field(HOPR,"0") field(LOPR,"0") field(HSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HHSV,"NO_ALARM") field(LLSV,"NO_ALARM") field(MDEL,"0") field(PRIO,"LOW") field(TSE, "-2") } record(ai,"BLEN:LI24:886:BL21B_S_SUM") { field(EGU, "") field(DESC,"sum B for display") field(DTYP,"BLM") field(INP, "#@0 3 1") field(SCAN,"I/O Intr") field(FLNK,"") # field(PINI,"YES") field(PREC,"3") field(HIGH,"0") field(LOW, "0") field(HIHI,"0") field(LOLO,"0") field(HOPR,"0") field(LOPR,"0") field(HSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HHSV,"NO_ALARM") field(LLSV,"NO_ALARM") field(MDEL,"0") field(PRIO,"LOW") field(TSE, "-2") } record(ai,"BLEN:LI24:886:BL21A_S_IPK") { field(EGU, "A") field(DESC,"Ipk A for display") field(DTYP,"BLM") field(INP, "#@0 3 4") field(SCAN,"1 second") field(FLNK,"") # field(PINI,"YES") field(PREC,"3") field(HIGH,"0") field(LOW, "0") field(HIHI,"0") field(LOLO,"0") field(HOPR,"0") field(LOPR,"0") field(HSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HHSV,"NO_ALARM") field(LLSV,"NO_ALARM") field(MDEL,"0") field(PRIO,"LOW") field(TSE, "-2") } record(ai,"BLEN:LI24:886:BL21B_S_IPK") { field(EGU, "A") field(DESC,"Ipk B for display") field(DTYP,"BLM") field(INP, "#@0 3 5") field(SCAN,"1 second") field(FLNK,"") # field(PINI,"YES") field(PREC,"3") field(HIGH,"0") field(LOW, "0") field(HIHI,"0") field(LOLO,"0") field(HOPR,"0") field(LOPR,"0") field(HSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HHSV,"NO_ALARM") field(LLSV,"NO_ALARM") field(MDEL,"0") field(PRIO,"LOW") field(TSE, "-2") } record(waveform, "BLEN:LI24:886:RWAV") { field(DESC, "Raw PAD Data") field(DTYP, "WavBuf") # card number selects PAD, signal number selects 'kind' field(INP, "#C3S0") field(SCAN, "I/O Intr") # use LOW or HIGH to end up on the 'diagnostic' or 'full-rate' scan list field(PRIO, "LOW") field(NELM, "2048") field(FTVL, "SHORT") field(EGU, "Counts") field(HOPR, "32767") field(LOPR, "-32768") field(TSE, "-2") field(FLNK, "BLEN:LI24:886:BL21A_S_R_WF") } record(aaiSubArr, "BLEN:LI24:886:BL21A_S_R_WF") { field(DESC, "Raw ADC data") field(INP, "BLEN:LI24:886:RWAV") field(NELM, "512") field(INDX, "0") field(FTVL, "SHORT") field(EGU, "Counts") field(HOPR, "32767") field(LOPR, "-32768") field(FLNK, "BLEN:LI24:886:BL21B_S_R_WF") } record(aaiSubArr, "BLEN:LI24:886:BL21B_S_R_WF") { field(DESC, "Raw ADC data") field(INP, "BLEN:LI24:886:RWAV") field(NELM, "512") field(INDX, "512") field(FTVL, "SHORT") field(EGU, "Counts") field(HOPR, "32767") field(LOPR, "-32768") field(FLNK, "BLEN:LI24:886:BL22A_S_R_WF") } record(aaiSubArr, "BLEN:LI24:886:BL22A_S_R_WF") { field(DESC, "Raw ADC data") field(INP, "BLEN:LI24:886:RWAV") field(NELM, "512") field(INDX, "1024") field(FTVL, "SHORT") field(EGU, "Counts") field(HOPR, "32767") field(LOPR, "-32768") field(FLNK, "BLEN:LI24:886:BL22B_S_R_WF") } record(aaiSubArr, "BLEN:LI24:886:BL22B_S_R_WF") { field(DESC, "Raw ADC data") field(INP, "BLEN:LI24:886:RWAV") field(NELM, "512") field(INDX, "1536") field(FTVL, "SHORT") field(EGU, "Counts") field(HOPR, "32767") field(LOPR, "-32768") } record(aai, "BLEN:LI24:886:BL21A_S_P_WF") { field(DESC, "Processed data for display") field(DTYP, "BLM_PROC") field(INP, "#C3S0") field(SCAN, "I/O Intr") field(PRIO, "LOW") # FTVL and NELM set from devSup } record(aai, "BLEN:LI24:886:BL21B_S_P_WF") { field(DESC, "Processed data for display") field(DTYP, "BLM_PROC") field(INP, "#C3S1") field(SCAN, "I/O Intr") field(PRIO, "LOW") # FTVL and NELM set from devSup } record(aao, "BLEN:LI24:886:BL21A_SCL_WF") { field(DESC, "Processed data for display") field(DTYP, "BLM_WEIGHT") field(OUT, "#C3S0") field(HOPR, "32767") field(LOPR, "-32768") field(PINI, "YES") info(autosaveFields,"VAL HOPR LOPR") # FTVL and NELM set from devSup } record(aao, "BLEN:LI24:886:BL21B_SCL_WF") { field(DESC, "Processed data for display") field(DTYP, "BLM_WEIGHT") field(OUT, "#C3S1") field(HOPR, "32767") field(LOPR, "-32768") field(PINI, "YES") info(autosaveFields,"VAL HOPR LOPR") # FTVL and NELM set from devSup }