# Receiver reponds to requests
record(bi, "HU1:CBPM:HU01:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar0")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU01:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU01:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc0,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU01:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg0,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU01:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU01:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU01:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU01:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU01:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU01:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr0,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU01:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU01:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU01:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU01:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU01:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU01:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU01:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr0,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU01:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU01:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU01:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU01:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU01:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU01:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU01:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr0,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU01:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU01:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU01:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU01:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU01:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU01:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU01:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr0,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU01:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU01:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU01:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU01:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU01:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar0")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU01:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar0")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU01:ATTY")  
}   

record(longin, "HU1:CBPM:HU01:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar0")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU01:ATTREF")  
}   

record(longin, "HU1:CBPM:HU01:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar0")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU01:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU01:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar0")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU01:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar0")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU01:PS_STA")
}

record(bi, "HU1:CBPM:HU01:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar0")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU01:LO_LTCH")
}

record(bi, "HU1:CBPM:HU01:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar0")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU01:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr0,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU01:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar0")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU01:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr0,rcvrSysReg(8,14,1),reg_io0")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU01:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr0,rcvrSysReg(6,8,1),reg_io0")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU01:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr0,rcvrSysReg(6,2,1),reg_io0")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU01:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar0")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar0")   
	field(FLNK, "HU1:CBPM:HU01:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU01:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar0")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU01:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU01:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU01:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU01:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU01:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU01:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU01:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU01:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU01:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU01:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU01:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU01:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU01:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU01:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU01:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU01:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU01:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr0,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU01:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar0")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU01:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU01:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar0")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU01:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU01:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar0")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU01:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU01:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar0")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU01:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU01:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar0")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU01:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU01:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar0")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU01:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU01:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar0")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU01:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU01:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar0")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU01:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU01:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar0")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU01:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar0")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU01:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU01:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar0")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU01:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU01:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar0")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU01:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU01:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar0")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU01:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU01:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar0")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU01:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU01:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar0")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU01:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU01:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar0")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU01:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU01:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar0")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU01:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU01:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll0,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU01:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU01:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU01:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU01:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU01:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU01:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU01:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU01:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU01:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU01:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU01:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU01:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU01:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU01:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU01:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU01:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU01:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU01:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU01:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU01:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU01:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU01:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU01:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU01:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU01:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU01:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU01:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU01:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU01:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU01:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU01:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU01:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU01:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU01:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU01:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU01:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU01:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU01:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU01:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU01:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU01:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU01:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU01:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU01:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU01:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU01:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU01:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU01:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU01:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU01:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU01:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU01:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU01:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU01:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU01:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU01:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU01:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU01:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU01:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU01:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU01:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU01:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU01:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU01:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU01:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU01:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU01:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU01:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU01:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU01:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU01:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU01:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU01:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU01:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU01:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU01:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU01:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU01:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU01:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU01:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU01:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU01:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU01:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU01:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU01:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU01:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU01:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU01:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU01:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU01:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU01:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU01:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU01:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_CHIP_PIN initializes HU1:CBPM:HU01:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_CHIP_SPI initializes HU1:CBPM:HU01:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_RST_CLKS initializes HU1:CBPM:HU01:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_RST_BIAS initializes HU1:CBPM:HU01:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_RST_PFD initializes HU1:CBPM:HU01:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_RST_CP initializes HU1:CBPM:HU01:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_RST_REF initializes HU1:CBPM:HU01:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_RST_VCO initializes HU1:CBPM:HU01:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_RST_IO initializes HU1:CBPM:HU01:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_FRAC_RST initializes HU1:CBPM:HU01:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_FRACBUFF_RST initializes HU1:CBPM:HU01:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_FRACBYP initializes HU1:CBPM:HU01:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_AUTOSEED initializes HU1:CBPM:HU01:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_FSK initializes HU1:CBPM:HU01:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_REFCLK initializes HU1:CBPM:HU01:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_INVCLK initializes HU1:CBPM:HU01:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_ILKD initializes HU1:CBPM:HU01:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_ASYMW initializes HU1:CBPM:HU01:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_ASYMWUP initializes HU1:CBPM:HU01:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_ROSC initializes HU1:CBPM:HU01:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_ROSCTEST initializes HU1:CBPM:HU01:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_CSP initializes HU1:CBPM:HU01:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_BIAS_EN initializes HU1:CBPM:HU01:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_CP_EN initializes HU1:CBPM:HU01:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_PFD_EN initializes HU1:CBPM:HU01:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_REF_EN initializes HU1:CBPM:HU01:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_VCO_EN initializes HU1:CBPM:HU01:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_GPIO_EN initializes HU1:CBPM:HU01:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_LD_EN initializes HU1:CBPM:HU01:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_CLKDIG_EN initializes HU1:CBPM:HU01:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_DIV_EN initializes HU1:CBPM:HU01:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_DCYC_EN initializes HU1:CBPM:HU01:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_REFDIG_EN initializes HU1:CBPM:HU01:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_RDIVDIG_EN initializes HU1:CBPM:HU01:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_VCOSPI_EN initializes HU1:CBPM:HU01:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_PHASSEL initializes HU1:CBPM:HU01:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_PFDUP_EN initializes HU1:CBPM:HU01:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_PFDDN_EN initializes HU1:CBPM:HU01:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_PFDLD_EN initializes HU1:CBPM:HU01:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_PFDUP initializes HU1:CBPM:HU01:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_PFDDN initializes HU1:CBPM:HU01:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU01:PLL_PFDMUTE initializes HU1:CBPM:HU01:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU01:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU01:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU01:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU01:PLL_CSPCORR initializes HU1:CBPM:HU01:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU01:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU01:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU01:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU01:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU01:PLL_LKDW initializes HU1:CBPM:HU01:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU01:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU01:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU01:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU01:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU01:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU01:PLL_PFDDLY initializes HU1:CBPM:HU01:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU01:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU01:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU01:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU01:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU01:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU01:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU01:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU01:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU01:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU01:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU01:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU01:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU01:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU01:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU01:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU01:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU01:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU01:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU01:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU01:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU01:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU01:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU01:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU01:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU01:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU01:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU01:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU01:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU01:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU01:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU01:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU01:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU01:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU01:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU01:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU01:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU01:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU01:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU01:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU01:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU01:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU01:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU01:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU01:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU01:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU01:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU01:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU01:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU01:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU01:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU01:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU01:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU01:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU01:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU01:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU01:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU01:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU01:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU01:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU01:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU01:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU01:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU01:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU01:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU01:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU01:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU01:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU01:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU01:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU01:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU01:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU01:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU01:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU01:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU01:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU01:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU01:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU01:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU01:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU01:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU01:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU01:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU01:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU01:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU01:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU01:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU01:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU01:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU01:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU01:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU01:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU01:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU01:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU01:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU01:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU01:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU01:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU01:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU01:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU01:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU01:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU01:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU01:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU01:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU01:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU01:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU01:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU01:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU01:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU01:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU01:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU01:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU01:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU01:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU01:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU01:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU01:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU01:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU01:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU01:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU01:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU01:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU01:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU01:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU01:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU01:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU01:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU01:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU01:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU01:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU01:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU01:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU01:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU01:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU01:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU01:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU01:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU01:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU01:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU01:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU01:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU01:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU01:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU01:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU01:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU01:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU01:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU01:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU01:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU02:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar1")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU02:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU02:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc1,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU02:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg1,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU02:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU02:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU02:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU02:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU02:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU02:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr1,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU02:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU02:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU02:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU02:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU02:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU02:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU02:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr1,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU02:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU02:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU02:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU02:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU02:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU02:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU02:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr1,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU02:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU02:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU02:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU02:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU02:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU02:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU02:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr1,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU02:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU02:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU02:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU02:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU02:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar1")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU02:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar1")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU02:ATTY")  
}   

record(longin, "HU1:CBPM:HU02:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar1")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU02:ATTREF")  
}   

record(longin, "HU1:CBPM:HU02:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar1")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU02:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU02:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar1")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU02:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar1")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU02:PS_STA")
}

record(bi, "HU1:CBPM:HU02:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar1")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU02:LO_LTCH")
}

record(bi, "HU1:CBPM:HU02:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar1")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU02:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr1,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU02:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar1")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU02:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr1,rcvrSysReg(8,14,1),reg_io1")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU02:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr1,rcvrSysReg(6,8,1),reg_io1")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU02:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr1,rcvrSysReg(6,2,1),reg_io1")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU02:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar1")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar1")   
	field(FLNK, "HU1:CBPM:HU02:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU02:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar1")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU02:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU02:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU02:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU02:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU02:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU02:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU02:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU02:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU02:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU02:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU02:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU02:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU02:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU02:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU02:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU02:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU02:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr1,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU02:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar1")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU02:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU02:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar1")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU02:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU02:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar1")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU02:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU02:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar1")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU02:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU02:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar1")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU02:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU02:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar1")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU02:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU02:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar1")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU02:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU02:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar1")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU02:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU02:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar1")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU02:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar1")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU02:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU02:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar1")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU02:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU02:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar1")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU02:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU02:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar1")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU02:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU02:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar1")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU02:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU02:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar1")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU02:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU02:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar1")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU02:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU02:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar1")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU02:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU02:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll1,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU02:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU02:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU02:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU02:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU02:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU02:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU02:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU02:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU02:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU02:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU02:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU02:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU02:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU02:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU02:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU02:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU02:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU02:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU02:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU02:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU02:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU02:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU02:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU02:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU02:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU02:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU02:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU02:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU02:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU02:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU02:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU02:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU02:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU02:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU02:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU02:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU02:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU02:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU02:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU02:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU02:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU02:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU02:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU02:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU02:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU02:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU02:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU02:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU02:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU02:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU02:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU02:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU02:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU02:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU02:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU02:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU02:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU02:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU02:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU02:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU02:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU02:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU02:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU02:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU02:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU02:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU02:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU02:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU02:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU02:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU02:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU02:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU02:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU02:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU02:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU02:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU02:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU02:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU02:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU02:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU02:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU02:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU02:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU02:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU02:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU02:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU02:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU02:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU02:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU02:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU02:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU02:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU02:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_CHIP_PIN initializes HU1:CBPM:HU02:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_CHIP_SPI initializes HU1:CBPM:HU02:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_RST_CLKS initializes HU1:CBPM:HU02:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_RST_BIAS initializes HU1:CBPM:HU02:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_RST_PFD initializes HU1:CBPM:HU02:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_RST_CP initializes HU1:CBPM:HU02:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_RST_REF initializes HU1:CBPM:HU02:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_RST_VCO initializes HU1:CBPM:HU02:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_RST_IO initializes HU1:CBPM:HU02:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_FRAC_RST initializes HU1:CBPM:HU02:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_FRACBUFF_RST initializes HU1:CBPM:HU02:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_FRACBYP initializes HU1:CBPM:HU02:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_AUTOSEED initializes HU1:CBPM:HU02:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_FSK initializes HU1:CBPM:HU02:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_REFCLK initializes HU1:CBPM:HU02:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_INVCLK initializes HU1:CBPM:HU02:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_ILKD initializes HU1:CBPM:HU02:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_ASYMW initializes HU1:CBPM:HU02:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_ASYMWUP initializes HU1:CBPM:HU02:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_ROSC initializes HU1:CBPM:HU02:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_ROSCTEST initializes HU1:CBPM:HU02:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_CSP initializes HU1:CBPM:HU02:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_BIAS_EN initializes HU1:CBPM:HU02:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_CP_EN initializes HU1:CBPM:HU02:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_PFD_EN initializes HU1:CBPM:HU02:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_REF_EN initializes HU1:CBPM:HU02:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_VCO_EN initializes HU1:CBPM:HU02:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_GPIO_EN initializes HU1:CBPM:HU02:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_LD_EN initializes HU1:CBPM:HU02:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_CLKDIG_EN initializes HU1:CBPM:HU02:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_DIV_EN initializes HU1:CBPM:HU02:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_DCYC_EN initializes HU1:CBPM:HU02:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_REFDIG_EN initializes HU1:CBPM:HU02:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_RDIVDIG_EN initializes HU1:CBPM:HU02:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_VCOSPI_EN initializes HU1:CBPM:HU02:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_PHASSEL initializes HU1:CBPM:HU02:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_PFDUP_EN initializes HU1:CBPM:HU02:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_PFDDN_EN initializes HU1:CBPM:HU02:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_PFDLD_EN initializes HU1:CBPM:HU02:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_PFDUP initializes HU1:CBPM:HU02:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_PFDDN initializes HU1:CBPM:HU02:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU02:PLL_PFDMUTE initializes HU1:CBPM:HU02:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU02:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU02:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU02:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU02:PLL_CSPCORR initializes HU1:CBPM:HU02:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU02:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU02:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU02:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU02:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU02:PLL_LKDW initializes HU1:CBPM:HU02:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU02:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU02:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU02:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU02:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU02:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU02:PLL_PFDDLY initializes HU1:CBPM:HU02:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU02:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU02:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU02:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU02:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU02:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU02:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU02:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU02:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU02:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU02:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU02:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU02:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU02:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU02:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU02:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU02:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU02:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU02:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU02:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU02:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU02:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU02:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU02:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU02:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU02:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU02:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU02:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU02:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU02:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU02:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU02:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU02:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU02:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU02:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU02:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU02:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU02:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU02:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU02:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU02:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU02:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU02:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU02:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU02:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU02:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU02:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU02:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU02:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU02:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU02:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU02:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU02:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU02:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU02:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU02:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU02:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU02:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU02:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU02:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU02:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU02:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU02:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU02:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU02:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU02:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU02:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU02:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU02:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU02:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU02:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU02:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU02:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU02:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU02:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU02:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU02:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU02:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU02:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU02:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU02:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU02:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU02:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU02:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU02:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU02:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU02:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU02:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU02:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU02:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU02:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU02:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU02:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU02:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU02:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU02:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU02:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU02:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU02:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU02:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU02:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU02:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU02:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU02:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU02:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU02:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU02:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU02:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU02:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU02:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU02:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU02:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU02:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU02:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU02:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU02:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU02:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU02:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU02:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU02:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU02:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU02:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU02:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU02:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU02:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU02:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU02:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU02:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU02:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU02:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU02:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU02:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU02:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU02:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU02:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU02:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU02:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU02:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU02:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU02:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU02:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU02:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU02:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU02:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU02:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU02:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU02:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU02:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU02:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU02:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU03:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar2")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU03:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU03:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc2,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU03:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg2,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU03:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU03:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU03:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU03:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU03:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU03:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr2,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU03:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU03:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU03:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU03:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU03:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU03:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU03:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr2,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU03:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU03:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU03:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU03:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU03:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU03:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU03:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr2,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU03:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU03:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU03:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU03:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU03:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU03:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU03:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr2,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU03:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU03:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU03:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU03:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU03:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar2")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU03:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar2")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU03:ATTY")  
}   

record(longin, "HU1:CBPM:HU03:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar2")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU03:ATTREF")  
}   

record(longin, "HU1:CBPM:HU03:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar2")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU03:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU03:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar2")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU03:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar2")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU03:PS_STA")
}

record(bi, "HU1:CBPM:HU03:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar2")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU03:LO_LTCH")
}

record(bi, "HU1:CBPM:HU03:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar2")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU03:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr2,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU03:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar2")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU03:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr2,rcvrSysReg(8,14,1),reg_io2")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU03:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr2,rcvrSysReg(6,8,1),reg_io2")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU03:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr2,rcvrSysReg(6,2,1),reg_io2")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU03:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar2")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar2")   
	field(FLNK, "HU1:CBPM:HU03:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU03:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar2")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU03:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU03:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU03:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU03:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU03:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU03:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU03:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU03:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU03:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU03:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU03:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU03:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU03:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU03:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU03:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU03:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU03:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr2,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU03:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar2")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU03:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU03:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar2")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU03:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU03:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar2")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU03:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU03:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar2")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU03:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU03:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar2")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU03:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU03:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar2")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU03:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU03:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar2")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU03:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU03:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar2")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU03:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU03:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar2")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU03:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar2")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU03:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU03:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar2")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU03:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU03:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar2")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU03:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU03:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar2")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU03:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU03:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar2")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU03:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU03:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar2")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU03:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU03:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar2")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU03:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU03:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar2")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU03:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU03:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll2,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU03:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU03:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU03:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU03:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU03:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU03:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU03:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU03:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU03:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU03:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU03:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU03:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU03:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU03:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU03:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU03:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU03:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU03:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU03:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU03:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU03:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU03:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU03:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU03:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU03:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU03:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU03:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU03:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU03:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU03:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU03:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU03:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU03:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU03:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU03:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU03:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU03:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU03:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU03:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU03:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU03:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU03:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU03:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU03:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU03:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU03:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU03:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU03:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU03:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU03:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU03:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU03:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU03:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU03:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU03:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU03:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU03:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU03:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU03:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU03:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU03:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU03:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU03:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU03:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU03:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU03:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU03:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU03:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU03:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU03:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU03:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU03:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU03:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU03:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU03:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU03:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU03:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU03:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU03:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU03:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU03:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU03:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU03:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU03:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU03:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU03:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU03:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU03:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU03:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU03:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU03:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU03:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU03:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_CHIP_PIN initializes HU1:CBPM:HU03:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_CHIP_SPI initializes HU1:CBPM:HU03:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_RST_CLKS initializes HU1:CBPM:HU03:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_RST_BIAS initializes HU1:CBPM:HU03:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_RST_PFD initializes HU1:CBPM:HU03:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_RST_CP initializes HU1:CBPM:HU03:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_RST_REF initializes HU1:CBPM:HU03:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_RST_VCO initializes HU1:CBPM:HU03:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_RST_IO initializes HU1:CBPM:HU03:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_FRAC_RST initializes HU1:CBPM:HU03:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_FRACBUFF_RST initializes HU1:CBPM:HU03:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_FRACBYP initializes HU1:CBPM:HU03:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_AUTOSEED initializes HU1:CBPM:HU03:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_FSK initializes HU1:CBPM:HU03:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_REFCLK initializes HU1:CBPM:HU03:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_INVCLK initializes HU1:CBPM:HU03:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_ILKD initializes HU1:CBPM:HU03:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_ASYMW initializes HU1:CBPM:HU03:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_ASYMWUP initializes HU1:CBPM:HU03:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_ROSC initializes HU1:CBPM:HU03:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_ROSCTEST initializes HU1:CBPM:HU03:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_CSP initializes HU1:CBPM:HU03:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_BIAS_EN initializes HU1:CBPM:HU03:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_CP_EN initializes HU1:CBPM:HU03:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_PFD_EN initializes HU1:CBPM:HU03:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_REF_EN initializes HU1:CBPM:HU03:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_VCO_EN initializes HU1:CBPM:HU03:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_GPIO_EN initializes HU1:CBPM:HU03:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_LD_EN initializes HU1:CBPM:HU03:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_CLKDIG_EN initializes HU1:CBPM:HU03:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_DIV_EN initializes HU1:CBPM:HU03:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_DCYC_EN initializes HU1:CBPM:HU03:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_REFDIG_EN initializes HU1:CBPM:HU03:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_RDIVDIG_EN initializes HU1:CBPM:HU03:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_VCOSPI_EN initializes HU1:CBPM:HU03:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_PHASSEL initializes HU1:CBPM:HU03:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_PFDUP_EN initializes HU1:CBPM:HU03:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_PFDDN_EN initializes HU1:CBPM:HU03:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_PFDLD_EN initializes HU1:CBPM:HU03:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_PFDUP initializes HU1:CBPM:HU03:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_PFDDN initializes HU1:CBPM:HU03:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU03:PLL_PFDMUTE initializes HU1:CBPM:HU03:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU03:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU03:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU03:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU03:PLL_CSPCORR initializes HU1:CBPM:HU03:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU03:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU03:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU03:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU03:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU03:PLL_LKDW initializes HU1:CBPM:HU03:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU03:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU03:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU03:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU03:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU03:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU03:PLL_PFDDLY initializes HU1:CBPM:HU03:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU03:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU03:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU03:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU03:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU03:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU03:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU03:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU03:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU03:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU03:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU03:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU03:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU03:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU03:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU03:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU03:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU03:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU03:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU03:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU03:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU03:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU03:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU03:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU03:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU03:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU03:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU03:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU03:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU03:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU03:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU03:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU03:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU03:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU03:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU03:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU03:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU03:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU03:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU03:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU03:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU03:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU03:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU03:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU03:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU03:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU03:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU03:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU03:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU03:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU03:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU03:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU03:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU03:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU03:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU03:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU03:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU03:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU03:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU03:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU03:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU03:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU03:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU03:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU03:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU03:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU03:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU03:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU03:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU03:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU03:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU03:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU03:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU03:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU03:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU03:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU03:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU03:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU03:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU03:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU03:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU03:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU03:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU03:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU03:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU03:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU03:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU03:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU03:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU03:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU03:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU03:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU03:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU03:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU03:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU03:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU03:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU03:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU03:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU03:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU03:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU03:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU03:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU03:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU03:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU03:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU03:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU03:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU03:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU03:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU03:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU03:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU03:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU03:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU03:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU03:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU03:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU03:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU03:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU03:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU03:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU03:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU03:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU03:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU03:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU03:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU03:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU03:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU03:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU03:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU03:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU03:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU03:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU03:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU03:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU03:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU03:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU03:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU03:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU03:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU03:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU03:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU03:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU03:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU03:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU03:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU03:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU03:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU03:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU03:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU04:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar3")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU04:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU04:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc3,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU04:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg3,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU04:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU04:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU04:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU04:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU04:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU04:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr3,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU04:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU04:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU04:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU04:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU04:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU04:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU04:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr3,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU04:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU04:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU04:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU04:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU04:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU04:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU04:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr3,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU04:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU04:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU04:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU04:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU04:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU04:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU04:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr3,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU04:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU04:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU04:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU04:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU04:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar3")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU04:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar3")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU04:ATTY")  
}   

record(longin, "HU1:CBPM:HU04:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar3")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU04:ATTREF")  
}   

record(longin, "HU1:CBPM:HU04:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar3")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU04:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU04:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar3")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU04:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar3")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU04:PS_STA")
}

record(bi, "HU1:CBPM:HU04:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar3")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU04:LO_LTCH")
}

record(bi, "HU1:CBPM:HU04:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar3")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU04:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr3,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU04:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar3")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU04:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr3,rcvrSysReg(8,14,1),reg_io3")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU04:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr3,rcvrSysReg(6,8,1),reg_io3")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU04:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr3,rcvrSysReg(6,2,1),reg_io3")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU04:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar3")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar3")   
	field(FLNK, "HU1:CBPM:HU04:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU04:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar3")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU04:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU04:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU04:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU04:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU04:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU04:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU04:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU04:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU04:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU04:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU04:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU04:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU04:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU04:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU04:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU04:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU04:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr3,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU04:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar3")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU04:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU04:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar3")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU04:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU04:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar3")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU04:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU04:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar3")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU04:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU04:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar3")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU04:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU04:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar3")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU04:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU04:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar3")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU04:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU04:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar3")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU04:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU04:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar3")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU04:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar3")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU04:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU04:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar3")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU04:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU04:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar3")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU04:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU04:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar3")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU04:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU04:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar3")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU04:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU04:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar3")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU04:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU04:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar3")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU04:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU04:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar3")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU04:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU04:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll3,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU04:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU04:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU04:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU04:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU04:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU04:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU04:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU04:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU04:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU04:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU04:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU04:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU04:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU04:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU04:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU04:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU04:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU04:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU04:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU04:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU04:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU04:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU04:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU04:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU04:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU04:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU04:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU04:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU04:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU04:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU04:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU04:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU04:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU04:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU04:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU04:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU04:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU04:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU04:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU04:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU04:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU04:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU04:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU04:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU04:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU04:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU04:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU04:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU04:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU04:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU04:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU04:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU04:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU04:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU04:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU04:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU04:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU04:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU04:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU04:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU04:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU04:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU04:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU04:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU04:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU04:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU04:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU04:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU04:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU04:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU04:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU04:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU04:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU04:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU04:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU04:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU04:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU04:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU04:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU04:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU04:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU04:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU04:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU04:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU04:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU04:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU04:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU04:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU04:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU04:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU04:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU04:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU04:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_CHIP_PIN initializes HU1:CBPM:HU04:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_CHIP_SPI initializes HU1:CBPM:HU04:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_RST_CLKS initializes HU1:CBPM:HU04:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_RST_BIAS initializes HU1:CBPM:HU04:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_RST_PFD initializes HU1:CBPM:HU04:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_RST_CP initializes HU1:CBPM:HU04:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_RST_REF initializes HU1:CBPM:HU04:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_RST_VCO initializes HU1:CBPM:HU04:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_RST_IO initializes HU1:CBPM:HU04:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_FRAC_RST initializes HU1:CBPM:HU04:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_FRACBUFF_RST initializes HU1:CBPM:HU04:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_FRACBYP initializes HU1:CBPM:HU04:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_AUTOSEED initializes HU1:CBPM:HU04:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_FSK initializes HU1:CBPM:HU04:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_REFCLK initializes HU1:CBPM:HU04:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_INVCLK initializes HU1:CBPM:HU04:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_ILKD initializes HU1:CBPM:HU04:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_ASYMW initializes HU1:CBPM:HU04:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_ASYMWUP initializes HU1:CBPM:HU04:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_ROSC initializes HU1:CBPM:HU04:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_ROSCTEST initializes HU1:CBPM:HU04:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_CSP initializes HU1:CBPM:HU04:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_BIAS_EN initializes HU1:CBPM:HU04:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_CP_EN initializes HU1:CBPM:HU04:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_PFD_EN initializes HU1:CBPM:HU04:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_REF_EN initializes HU1:CBPM:HU04:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_VCO_EN initializes HU1:CBPM:HU04:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_GPIO_EN initializes HU1:CBPM:HU04:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_LD_EN initializes HU1:CBPM:HU04:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_CLKDIG_EN initializes HU1:CBPM:HU04:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_DIV_EN initializes HU1:CBPM:HU04:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_DCYC_EN initializes HU1:CBPM:HU04:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_REFDIG_EN initializes HU1:CBPM:HU04:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_RDIVDIG_EN initializes HU1:CBPM:HU04:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_VCOSPI_EN initializes HU1:CBPM:HU04:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_PHASSEL initializes HU1:CBPM:HU04:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_PFDUP_EN initializes HU1:CBPM:HU04:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_PFDDN_EN initializes HU1:CBPM:HU04:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_PFDLD_EN initializes HU1:CBPM:HU04:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_PFDUP initializes HU1:CBPM:HU04:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_PFDDN initializes HU1:CBPM:HU04:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU04:PLL_PFDMUTE initializes HU1:CBPM:HU04:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU04:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU04:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU04:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU04:PLL_CSPCORR initializes HU1:CBPM:HU04:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU04:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU04:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU04:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU04:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU04:PLL_LKDW initializes HU1:CBPM:HU04:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU04:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU04:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU04:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU04:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU04:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU04:PLL_PFDDLY initializes HU1:CBPM:HU04:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU04:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU04:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU04:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU04:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU04:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU04:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU04:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU04:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU04:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU04:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU04:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU04:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU04:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU04:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU04:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU04:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU04:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU04:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU04:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU04:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU04:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU04:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU04:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU04:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU04:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU04:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU04:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU04:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU04:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU04:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU04:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU04:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU04:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU04:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU04:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU04:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU04:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU04:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU04:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU04:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU04:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU04:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU04:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU04:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU04:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU04:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU04:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU04:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU04:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU04:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU04:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU04:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU04:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU04:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU04:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU04:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU04:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU04:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU04:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU04:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU04:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU04:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU04:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU04:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU04:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU04:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU04:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU04:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU04:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU04:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU04:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU04:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU04:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU04:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU04:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU04:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU04:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU04:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU04:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU04:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU04:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU04:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU04:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU04:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU04:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU04:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU04:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU04:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU04:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU04:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU04:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU04:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU04:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU04:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU04:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU04:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU04:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU04:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU04:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU04:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU04:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU04:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU04:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU04:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU04:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU04:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU04:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU04:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU04:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU04:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU04:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU04:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU04:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU04:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU04:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU04:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU04:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU04:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU04:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU04:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU04:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU04:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU04:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU04:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU04:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU04:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU04:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU04:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU04:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU04:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU04:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU04:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU04:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU04:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU04:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU04:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU04:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU04:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU04:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU04:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU04:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU04:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU04:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU04:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU04:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU04:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU04:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU04:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU04:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU05:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar4")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU05:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU05:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc4,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU05:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg4,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU05:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU05:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU05:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU05:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU05:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU05:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr4,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU05:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU05:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU05:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU05:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU05:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU05:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU05:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr4,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU05:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU05:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU05:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU05:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU05:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU05:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU05:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr4,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU05:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU05:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU05:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU05:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU05:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU05:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU05:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr4,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU05:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU05:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU05:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU05:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU05:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar4")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU05:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar4")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU05:ATTY")  
}   

record(longin, "HU1:CBPM:HU05:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar4")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU05:ATTREF")  
}   

record(longin, "HU1:CBPM:HU05:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar4")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU05:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU05:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar4")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU05:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar4")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU05:PS_STA")
}

record(bi, "HU1:CBPM:HU05:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar4")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU05:LO_LTCH")
}

record(bi, "HU1:CBPM:HU05:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar4")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU05:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr4,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU05:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar4")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU05:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr4,rcvrSysReg(8,14,1),reg_io4")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU05:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr4,rcvrSysReg(6,8,1),reg_io4")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU05:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr4,rcvrSysReg(6,2,1),reg_io4")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU05:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar4")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar4")   
	field(FLNK, "HU1:CBPM:HU05:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU05:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar4")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU05:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU05:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU05:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU05:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU05:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU05:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU05:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU05:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU05:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU05:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU05:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU05:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU05:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU05:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU05:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU05:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU05:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr4,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU05:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar4")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU05:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU05:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar4")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU05:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU05:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar4")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU05:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU05:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar4")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU05:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU05:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar4")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU05:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU05:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar4")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU05:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU05:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar4")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU05:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU05:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar4")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU05:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU05:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar4")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU05:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar4")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU05:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU05:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar4")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU05:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU05:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar4")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU05:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU05:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar4")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU05:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU05:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar4")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU05:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU05:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar4")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU05:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU05:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar4")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU05:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU05:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar4")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU05:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU05:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll4,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU05:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU05:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU05:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU05:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU05:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU05:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU05:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU05:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU05:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU05:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU05:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU05:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU05:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU05:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU05:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU05:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU05:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU05:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU05:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU05:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU05:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU05:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU05:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU05:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU05:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU05:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU05:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU05:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU05:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU05:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU05:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU05:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU05:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU05:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU05:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU05:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU05:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU05:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU05:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU05:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU05:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU05:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU05:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU05:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU05:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU05:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU05:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU05:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU05:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU05:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU05:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU05:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU05:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU05:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU05:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU05:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU05:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU05:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU05:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU05:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU05:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU05:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU05:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU05:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU05:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU05:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU05:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU05:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU05:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU05:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU05:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU05:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU05:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU05:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU05:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU05:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU05:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU05:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU05:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU05:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU05:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU05:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU05:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU05:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU05:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU05:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU05:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU05:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU05:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU05:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU05:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU05:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU05:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_CHIP_PIN initializes HU1:CBPM:HU05:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_CHIP_SPI initializes HU1:CBPM:HU05:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_RST_CLKS initializes HU1:CBPM:HU05:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_RST_BIAS initializes HU1:CBPM:HU05:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_RST_PFD initializes HU1:CBPM:HU05:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_RST_CP initializes HU1:CBPM:HU05:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_RST_REF initializes HU1:CBPM:HU05:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_RST_VCO initializes HU1:CBPM:HU05:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_RST_IO initializes HU1:CBPM:HU05:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_FRAC_RST initializes HU1:CBPM:HU05:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_FRACBUFF_RST initializes HU1:CBPM:HU05:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_FRACBYP initializes HU1:CBPM:HU05:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_AUTOSEED initializes HU1:CBPM:HU05:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_FSK initializes HU1:CBPM:HU05:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_REFCLK initializes HU1:CBPM:HU05:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_INVCLK initializes HU1:CBPM:HU05:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_ILKD initializes HU1:CBPM:HU05:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_ASYMW initializes HU1:CBPM:HU05:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_ASYMWUP initializes HU1:CBPM:HU05:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_ROSC initializes HU1:CBPM:HU05:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_ROSCTEST initializes HU1:CBPM:HU05:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_CSP initializes HU1:CBPM:HU05:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_BIAS_EN initializes HU1:CBPM:HU05:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_CP_EN initializes HU1:CBPM:HU05:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_PFD_EN initializes HU1:CBPM:HU05:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_REF_EN initializes HU1:CBPM:HU05:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_VCO_EN initializes HU1:CBPM:HU05:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_GPIO_EN initializes HU1:CBPM:HU05:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_LD_EN initializes HU1:CBPM:HU05:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_CLKDIG_EN initializes HU1:CBPM:HU05:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_DIV_EN initializes HU1:CBPM:HU05:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_DCYC_EN initializes HU1:CBPM:HU05:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_REFDIG_EN initializes HU1:CBPM:HU05:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_RDIVDIG_EN initializes HU1:CBPM:HU05:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_VCOSPI_EN initializes HU1:CBPM:HU05:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_PHASSEL initializes HU1:CBPM:HU05:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_PFDUP_EN initializes HU1:CBPM:HU05:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_PFDDN_EN initializes HU1:CBPM:HU05:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_PFDLD_EN initializes HU1:CBPM:HU05:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_PFDUP initializes HU1:CBPM:HU05:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_PFDDN initializes HU1:CBPM:HU05:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU05:PLL_PFDMUTE initializes HU1:CBPM:HU05:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU05:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU05:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU05:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU05:PLL_CSPCORR initializes HU1:CBPM:HU05:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU05:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU05:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU05:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU05:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU05:PLL_LKDW initializes HU1:CBPM:HU05:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU05:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU05:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU05:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU05:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU05:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU05:PLL_PFDDLY initializes HU1:CBPM:HU05:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU05:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU05:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU05:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU05:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU05:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU05:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU05:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU05:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU05:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU05:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU05:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU05:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU05:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU05:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU05:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU05:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU05:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU05:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU05:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU05:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU05:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU05:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU05:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU05:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU05:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU05:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU05:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU05:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU05:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU05:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU05:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU05:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU05:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU05:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU05:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU05:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU05:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU05:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU05:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU05:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU05:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU05:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU05:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU05:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU05:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU05:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU05:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU05:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU05:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU05:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU05:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU05:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU05:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU05:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU05:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU05:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU05:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU05:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU05:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU05:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU05:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU05:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU05:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU05:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU05:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU05:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU05:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU05:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU05:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU05:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU05:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU05:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU05:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU05:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU05:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU05:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU05:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU05:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU05:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU05:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU05:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU05:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU05:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU05:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU05:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU05:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU05:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU05:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU05:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU05:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU05:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU05:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU05:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU05:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU05:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU05:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU05:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU05:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU05:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU05:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU05:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU05:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU05:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU05:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU05:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU05:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU05:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU05:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU05:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU05:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU05:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU05:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU05:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU05:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU05:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU05:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU05:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU05:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU05:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU05:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU05:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU05:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU05:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU05:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU05:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU05:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU05:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU05:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU05:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU05:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU05:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU05:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU05:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU05:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU05:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU05:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU05:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU05:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU05:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU05:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU05:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU05:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU05:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU05:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU05:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU05:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU05:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU05:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU05:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU06:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar5")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU06:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU06:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc5,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU06:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg5,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU06:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU06:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU06:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU06:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU06:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU06:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr5,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU06:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU06:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU06:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU06:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU06:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU06:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU06:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr5,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU06:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU06:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU06:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU06:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU06:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU06:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU06:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr5,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU06:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU06:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU06:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU06:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU06:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU06:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU06:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr5,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU06:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU06:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU06:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU06:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU06:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar5")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU06:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar5")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU06:ATTY")  
}   

record(longin, "HU1:CBPM:HU06:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar5")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU06:ATTREF")  
}   

record(longin, "HU1:CBPM:HU06:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar5")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU06:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU06:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar5")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU06:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar5")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU06:PS_STA")
}

record(bi, "HU1:CBPM:HU06:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar5")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU06:LO_LTCH")
}

record(bi, "HU1:CBPM:HU06:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar5")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU06:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr5,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU06:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar5")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU06:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr5,rcvrSysReg(8,14,1),reg_io5")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU06:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr5,rcvrSysReg(6,8,1),reg_io5")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU06:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr5,rcvrSysReg(6,2,1),reg_io5")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU06:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar5")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar5")   
	field(FLNK, "HU1:CBPM:HU06:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU06:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar5")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU06:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU06:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU06:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU06:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU06:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU06:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU06:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU06:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU06:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU06:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU06:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU06:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU06:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU06:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU06:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU06:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU06:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr5,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU06:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar5")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU06:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU06:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar5")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU06:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU06:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar5")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU06:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU06:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar5")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU06:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU06:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar5")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU06:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU06:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar5")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU06:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU06:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar5")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU06:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU06:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar5")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU06:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU06:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar5")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU06:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar5")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU06:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU06:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar5")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU06:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU06:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar5")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU06:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU06:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar5")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU06:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU06:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar5")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU06:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU06:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar5")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU06:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU06:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar5")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU06:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU06:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar5")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU06:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU06:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll5,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU06:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU06:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU06:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU06:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU06:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU06:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU06:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU06:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU06:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU06:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU06:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU06:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU06:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU06:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU06:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU06:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU06:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU06:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU06:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU06:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU06:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU06:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU06:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU06:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU06:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU06:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU06:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU06:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU06:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU06:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU06:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU06:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU06:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU06:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU06:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU06:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU06:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU06:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU06:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU06:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU06:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU06:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU06:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU06:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU06:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU06:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU06:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU06:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU06:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU06:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU06:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU06:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU06:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU06:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU06:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU06:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU06:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU06:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU06:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU06:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU06:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU06:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU06:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU06:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU06:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU06:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU06:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU06:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU06:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU06:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU06:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU06:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU06:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU06:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU06:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU06:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU06:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU06:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU06:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU06:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU06:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU06:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU06:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU06:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU06:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU06:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU06:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU06:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU06:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU06:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU06:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU06:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU06:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_CHIP_PIN initializes HU1:CBPM:HU06:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_CHIP_SPI initializes HU1:CBPM:HU06:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_RST_CLKS initializes HU1:CBPM:HU06:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_RST_BIAS initializes HU1:CBPM:HU06:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_RST_PFD initializes HU1:CBPM:HU06:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_RST_CP initializes HU1:CBPM:HU06:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_RST_REF initializes HU1:CBPM:HU06:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_RST_VCO initializes HU1:CBPM:HU06:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_RST_IO initializes HU1:CBPM:HU06:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_FRAC_RST initializes HU1:CBPM:HU06:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_FRACBUFF_RST initializes HU1:CBPM:HU06:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_FRACBYP initializes HU1:CBPM:HU06:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_AUTOSEED initializes HU1:CBPM:HU06:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_FSK initializes HU1:CBPM:HU06:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_REFCLK initializes HU1:CBPM:HU06:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_INVCLK initializes HU1:CBPM:HU06:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_ILKD initializes HU1:CBPM:HU06:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_ASYMW initializes HU1:CBPM:HU06:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_ASYMWUP initializes HU1:CBPM:HU06:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_ROSC initializes HU1:CBPM:HU06:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_ROSCTEST initializes HU1:CBPM:HU06:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_CSP initializes HU1:CBPM:HU06:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_BIAS_EN initializes HU1:CBPM:HU06:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_CP_EN initializes HU1:CBPM:HU06:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_PFD_EN initializes HU1:CBPM:HU06:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_REF_EN initializes HU1:CBPM:HU06:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_VCO_EN initializes HU1:CBPM:HU06:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_GPIO_EN initializes HU1:CBPM:HU06:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_LD_EN initializes HU1:CBPM:HU06:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_CLKDIG_EN initializes HU1:CBPM:HU06:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_DIV_EN initializes HU1:CBPM:HU06:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_DCYC_EN initializes HU1:CBPM:HU06:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_REFDIG_EN initializes HU1:CBPM:HU06:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_RDIVDIG_EN initializes HU1:CBPM:HU06:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_VCOSPI_EN initializes HU1:CBPM:HU06:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_PHASSEL initializes HU1:CBPM:HU06:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_PFDUP_EN initializes HU1:CBPM:HU06:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_PFDDN_EN initializes HU1:CBPM:HU06:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_PFDLD_EN initializes HU1:CBPM:HU06:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_PFDUP initializes HU1:CBPM:HU06:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_PFDDN initializes HU1:CBPM:HU06:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU06:PLL_PFDMUTE initializes HU1:CBPM:HU06:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU06:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU06:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU06:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU06:PLL_CSPCORR initializes HU1:CBPM:HU06:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU06:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU06:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU06:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU06:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU06:PLL_LKDW initializes HU1:CBPM:HU06:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU06:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU06:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU06:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU06:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU06:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU06:PLL_PFDDLY initializes HU1:CBPM:HU06:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU06:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU06:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU06:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU06:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU06:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU06:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU06:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU06:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU06:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU06:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU06:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU06:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU06:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU06:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU06:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU06:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU06:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU06:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU06:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU06:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU06:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU06:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU06:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU06:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU06:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU06:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU06:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU06:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU06:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU06:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU06:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU06:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU06:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU06:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU06:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU06:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU06:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU06:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU06:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU06:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU06:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU06:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU06:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU06:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU06:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU06:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU06:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU06:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU06:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU06:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU06:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU06:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU06:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU06:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU06:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU06:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU06:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU06:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU06:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU06:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU06:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU06:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU06:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU06:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU06:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU06:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU06:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU06:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU06:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU06:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU06:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU06:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU06:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU06:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU06:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU06:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU06:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU06:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU06:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU06:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU06:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU06:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU06:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU06:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU06:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU06:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU06:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU06:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU06:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU06:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU06:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU06:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU06:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU06:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU06:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU06:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU06:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU06:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU06:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU06:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU06:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU06:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU06:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU06:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU06:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU06:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU06:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU06:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU06:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU06:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU06:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU06:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU06:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU06:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU06:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU06:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU06:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU06:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU06:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU06:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU06:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU06:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU06:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU06:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU06:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU06:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU06:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU06:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU06:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU06:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU06:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU06:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU06:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU06:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU06:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU06:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU06:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU06:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU06:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU06:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU06:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU06:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU06:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU06:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU06:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU06:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU06:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU06:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU06:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU07:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar6")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU07:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU07:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc6,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU07:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg6,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU07:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU07:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU07:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU07:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU07:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU07:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr6,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU07:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU07:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU07:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU07:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU07:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU07:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU07:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr6,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU07:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU07:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU07:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU07:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU07:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU07:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU07:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr6,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU07:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU07:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU07:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU07:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU07:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU07:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU07:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr6,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU07:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU07:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU07:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU07:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU07:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar6")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU07:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar6")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU07:ATTY")  
}   

record(longin, "HU1:CBPM:HU07:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar6")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU07:ATTREF")  
}   

record(longin, "HU1:CBPM:HU07:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar6")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU07:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU07:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar6")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU07:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar6")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU07:PS_STA")
}

record(bi, "HU1:CBPM:HU07:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar6")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU07:LO_LTCH")
}

record(bi, "HU1:CBPM:HU07:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar6")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU07:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr6,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU07:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar6")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU07:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr6,rcvrSysReg(8,14,1),reg_io6")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU07:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr6,rcvrSysReg(6,8,1),reg_io6")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU07:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr6,rcvrSysReg(6,2,1),reg_io6")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU07:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar6")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar6")   
	field(FLNK, "HU1:CBPM:HU07:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU07:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar6")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU07:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU07:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU07:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU07:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU07:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU07:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU07:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU07:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU07:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU07:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU07:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU07:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU07:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU07:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU07:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU07:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU07:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr6,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU07:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar6")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU07:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU07:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar6")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU07:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU07:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar6")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU07:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU07:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar6")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU07:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU07:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar6")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU07:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU07:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar6")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU07:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU07:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar6")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU07:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU07:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar6")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU07:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU07:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar6")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU07:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar6")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU07:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU07:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar6")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU07:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU07:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar6")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU07:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU07:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar6")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU07:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU07:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar6")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU07:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU07:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar6")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU07:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU07:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar6")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU07:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU07:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar6")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU07:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU07:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll6,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU07:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU07:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU07:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU07:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU07:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU07:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU07:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU07:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU07:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU07:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU07:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU07:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU07:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU07:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU07:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU07:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU07:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU07:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU07:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU07:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU07:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU07:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU07:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU07:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU07:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU07:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU07:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU07:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU07:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU07:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU07:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU07:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU07:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU07:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU07:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU07:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU07:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU07:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU07:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU07:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU07:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU07:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU07:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU07:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU07:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU07:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU07:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU07:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU07:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU07:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU07:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU07:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU07:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU07:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU07:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU07:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU07:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU07:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU07:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU07:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU07:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU07:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU07:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU07:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU07:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU07:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU07:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU07:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU07:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU07:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU07:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU07:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU07:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU07:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU07:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU07:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU07:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU07:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU07:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU07:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU07:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU07:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU07:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU07:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU07:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU07:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU07:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU07:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU07:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU07:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU07:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU07:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU07:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_CHIP_PIN initializes HU1:CBPM:HU07:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_CHIP_SPI initializes HU1:CBPM:HU07:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_RST_CLKS initializes HU1:CBPM:HU07:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_RST_BIAS initializes HU1:CBPM:HU07:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_RST_PFD initializes HU1:CBPM:HU07:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_RST_CP initializes HU1:CBPM:HU07:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_RST_REF initializes HU1:CBPM:HU07:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_RST_VCO initializes HU1:CBPM:HU07:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_RST_IO initializes HU1:CBPM:HU07:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_FRAC_RST initializes HU1:CBPM:HU07:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_FRACBUFF_RST initializes HU1:CBPM:HU07:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_FRACBYP initializes HU1:CBPM:HU07:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_AUTOSEED initializes HU1:CBPM:HU07:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_FSK initializes HU1:CBPM:HU07:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_REFCLK initializes HU1:CBPM:HU07:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_INVCLK initializes HU1:CBPM:HU07:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_ILKD initializes HU1:CBPM:HU07:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_ASYMW initializes HU1:CBPM:HU07:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_ASYMWUP initializes HU1:CBPM:HU07:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_ROSC initializes HU1:CBPM:HU07:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_ROSCTEST initializes HU1:CBPM:HU07:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_CSP initializes HU1:CBPM:HU07:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_BIAS_EN initializes HU1:CBPM:HU07:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_CP_EN initializes HU1:CBPM:HU07:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_PFD_EN initializes HU1:CBPM:HU07:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_REF_EN initializes HU1:CBPM:HU07:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_VCO_EN initializes HU1:CBPM:HU07:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_GPIO_EN initializes HU1:CBPM:HU07:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_LD_EN initializes HU1:CBPM:HU07:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_CLKDIG_EN initializes HU1:CBPM:HU07:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_DIV_EN initializes HU1:CBPM:HU07:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_DCYC_EN initializes HU1:CBPM:HU07:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_REFDIG_EN initializes HU1:CBPM:HU07:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_RDIVDIG_EN initializes HU1:CBPM:HU07:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_VCOSPI_EN initializes HU1:CBPM:HU07:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_PHASSEL initializes HU1:CBPM:HU07:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_PFDUP_EN initializes HU1:CBPM:HU07:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_PFDDN_EN initializes HU1:CBPM:HU07:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_PFDLD_EN initializes HU1:CBPM:HU07:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_PFDUP initializes HU1:CBPM:HU07:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_PFDDN initializes HU1:CBPM:HU07:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU07:PLL_PFDMUTE initializes HU1:CBPM:HU07:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU07:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU07:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU07:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU07:PLL_CSPCORR initializes HU1:CBPM:HU07:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU07:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU07:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU07:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU07:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU07:PLL_LKDW initializes HU1:CBPM:HU07:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU07:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU07:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU07:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU07:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU07:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU07:PLL_PFDDLY initializes HU1:CBPM:HU07:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU07:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU07:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU07:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU07:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU07:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU07:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU07:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU07:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU07:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU07:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU07:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU07:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU07:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU07:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU07:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU07:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU07:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU07:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU07:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU07:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU07:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU07:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU07:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU07:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU07:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU07:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU07:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU07:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU07:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU07:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU07:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU07:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU07:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU07:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU07:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU07:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU07:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU07:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU07:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU07:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU07:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU07:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU07:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU07:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU07:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU07:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU07:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU07:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU07:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU07:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU07:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU07:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU07:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU07:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU07:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU07:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU07:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU07:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU07:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU07:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU07:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU07:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU07:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU07:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU07:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU07:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU07:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU07:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU07:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU07:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU07:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU07:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU07:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU07:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU07:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU07:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU07:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU07:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU07:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU07:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU07:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU07:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU07:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU07:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU07:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU07:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU07:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU07:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU07:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU07:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU07:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU07:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU07:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU07:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU07:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU07:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU07:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU07:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU07:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU07:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU07:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU07:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU07:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU07:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU07:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU07:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU07:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU07:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU07:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU07:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU07:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU07:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU07:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU07:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU07:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU07:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU07:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU07:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU07:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU07:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU07:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU07:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU07:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU07:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU07:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU07:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU07:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU07:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU07:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU07:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU07:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU07:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU07:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU07:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU07:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU07:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU07:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU07:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU07:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU07:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU07:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU07:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU07:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU07:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU07:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU07:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU07:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU07:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU07:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU08:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar7")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU08:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU08:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc7,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU08:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg7,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU08:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU08:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU08:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU08:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU08:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU08:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr7,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU08:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU08:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU08:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU08:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU08:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU08:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU08:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr7,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU08:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU08:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU08:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU08:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU08:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU08:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU08:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr7,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU08:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU08:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU08:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU08:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU08:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU08:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU08:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr7,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU08:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU08:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU08:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU08:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU08:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar7")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU08:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar7")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU08:ATTY")  
}   

record(longin, "HU1:CBPM:HU08:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar7")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU08:ATTREF")  
}   

record(longin, "HU1:CBPM:HU08:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar7")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU08:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU08:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar7")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU08:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar7")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU08:PS_STA")
}

record(bi, "HU1:CBPM:HU08:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar7")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU08:LO_LTCH")
}

record(bi, "HU1:CBPM:HU08:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar7")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU08:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr7,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU08:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar7")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU08:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr7,rcvrSysReg(8,14,1),reg_io7")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU08:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr7,rcvrSysReg(6,8,1),reg_io7")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU08:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr7,rcvrSysReg(6,2,1),reg_io7")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU08:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar7")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar7")   
	field(FLNK, "HU1:CBPM:HU08:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU08:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar7")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU08:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU08:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU08:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU08:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU08:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU08:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU08:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU08:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU08:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU08:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU08:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU08:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU08:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU08:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU08:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU08:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU08:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr7,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU08:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar7")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU08:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU08:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar7")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU08:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU08:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar7")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU08:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU08:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar7")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU08:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU08:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar7")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU08:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU08:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar7")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU08:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU08:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar7")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU08:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU08:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar7")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU08:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU08:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar7")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU08:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar7")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU08:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU08:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar7")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU08:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU08:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar7")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU08:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU08:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar7")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU08:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU08:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar7")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU08:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU08:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar7")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU08:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU08:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar7")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU08:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU08:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar7")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU08:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU08:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll7,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU08:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU08:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU08:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU08:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU08:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU08:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU08:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU08:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU08:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU08:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU08:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU08:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU08:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU08:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU08:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU08:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU08:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU08:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU08:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU08:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU08:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU08:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU08:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU08:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU08:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU08:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU08:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU08:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU08:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU08:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU08:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU08:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU08:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU08:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU08:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU08:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU08:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU08:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU08:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU08:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU08:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU08:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU08:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU08:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU08:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU08:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU08:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU08:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU08:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU08:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU08:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU08:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU08:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU08:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU08:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU08:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU08:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU08:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU08:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU08:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU08:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU08:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU08:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU08:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU08:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU08:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU08:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU08:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU08:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU08:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU08:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU08:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU08:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU08:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU08:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU08:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU08:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU08:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU08:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU08:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU08:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU08:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU08:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU08:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU08:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU08:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU08:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU08:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU08:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU08:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU08:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU08:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU08:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_CHIP_PIN initializes HU1:CBPM:HU08:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_CHIP_SPI initializes HU1:CBPM:HU08:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_RST_CLKS initializes HU1:CBPM:HU08:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_RST_BIAS initializes HU1:CBPM:HU08:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_RST_PFD initializes HU1:CBPM:HU08:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_RST_CP initializes HU1:CBPM:HU08:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_RST_REF initializes HU1:CBPM:HU08:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_RST_VCO initializes HU1:CBPM:HU08:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_RST_IO initializes HU1:CBPM:HU08:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_FRAC_RST initializes HU1:CBPM:HU08:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_FRACBUFF_RST initializes HU1:CBPM:HU08:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_FRACBYP initializes HU1:CBPM:HU08:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_AUTOSEED initializes HU1:CBPM:HU08:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_FSK initializes HU1:CBPM:HU08:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_REFCLK initializes HU1:CBPM:HU08:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_INVCLK initializes HU1:CBPM:HU08:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_ILKD initializes HU1:CBPM:HU08:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_ASYMW initializes HU1:CBPM:HU08:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_ASYMWUP initializes HU1:CBPM:HU08:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_ROSC initializes HU1:CBPM:HU08:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_ROSCTEST initializes HU1:CBPM:HU08:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_CSP initializes HU1:CBPM:HU08:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_BIAS_EN initializes HU1:CBPM:HU08:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_CP_EN initializes HU1:CBPM:HU08:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_PFD_EN initializes HU1:CBPM:HU08:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_REF_EN initializes HU1:CBPM:HU08:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_VCO_EN initializes HU1:CBPM:HU08:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_GPIO_EN initializes HU1:CBPM:HU08:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_LD_EN initializes HU1:CBPM:HU08:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_CLKDIG_EN initializes HU1:CBPM:HU08:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_DIV_EN initializes HU1:CBPM:HU08:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_DCYC_EN initializes HU1:CBPM:HU08:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_REFDIG_EN initializes HU1:CBPM:HU08:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_RDIVDIG_EN initializes HU1:CBPM:HU08:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_VCOSPI_EN initializes HU1:CBPM:HU08:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_PHASSEL initializes HU1:CBPM:HU08:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_PFDUP_EN initializes HU1:CBPM:HU08:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_PFDDN_EN initializes HU1:CBPM:HU08:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_PFDLD_EN initializes HU1:CBPM:HU08:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_PFDUP initializes HU1:CBPM:HU08:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_PFDDN initializes HU1:CBPM:HU08:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU08:PLL_PFDMUTE initializes HU1:CBPM:HU08:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU08:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU08:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU08:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU08:PLL_CSPCORR initializes HU1:CBPM:HU08:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU08:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU08:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU08:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU08:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU08:PLL_LKDW initializes HU1:CBPM:HU08:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU08:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU08:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU08:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU08:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU08:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU08:PLL_PFDDLY initializes HU1:CBPM:HU08:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU08:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU08:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU08:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU08:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU08:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU08:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU08:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU08:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU08:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU08:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU08:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU08:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU08:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU08:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU08:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU08:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU08:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU08:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU08:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU08:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU08:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU08:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU08:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU08:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU08:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU08:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU08:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU08:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU08:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU08:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU08:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU08:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU08:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU08:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU08:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU08:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU08:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU08:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU08:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU08:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU08:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU08:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU08:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU08:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU08:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU08:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU08:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU08:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU08:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU08:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU08:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU08:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU08:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU08:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU08:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU08:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU08:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU08:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU08:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU08:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU08:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU08:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU08:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU08:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU08:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU08:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU08:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU08:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU08:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU08:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU08:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU08:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU08:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU08:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU08:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU08:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU08:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU08:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU08:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU08:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU08:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU08:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU08:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU08:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU08:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU08:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU08:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU08:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU08:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU08:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU08:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU08:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU08:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU08:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU08:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU08:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU08:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU08:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU08:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU08:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU08:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU08:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU08:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU08:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU08:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU08:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU08:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU08:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU08:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU08:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU08:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU08:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU08:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU08:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU08:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU08:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU08:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU08:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU08:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU08:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU08:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU08:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU08:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU08:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU08:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU08:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU08:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU08:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU08:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU08:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU08:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU08:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU08:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU08:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU08:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU08:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU08:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU08:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU08:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU08:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU08:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU08:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU08:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU08:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU08:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU08:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU08:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU08:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU08:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU09:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar8")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU09:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU09:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc8,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU09:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg8,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU09:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU09:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU09:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU09:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU09:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU09:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr8,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU09:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU09:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU09:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU09:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU09:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU09:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU09:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr8,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU09:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU09:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU09:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU09:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU09:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU09:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU09:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr8,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU09:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU09:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU09:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU09:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU09:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU09:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU09:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr8,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU09:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU09:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU09:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU09:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU09:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar8")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU09:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar8")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU09:ATTY")  
}   

record(longin, "HU1:CBPM:HU09:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar8")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU09:ATTREF")  
}   

record(longin, "HU1:CBPM:HU09:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar8")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU09:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU09:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar8")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU09:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar8")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU09:PS_STA")
}

record(bi, "HU1:CBPM:HU09:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar8")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU09:LO_LTCH")
}

record(bi, "HU1:CBPM:HU09:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar8")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU09:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr8,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU09:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar8")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU09:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr8,rcvrSysReg(8,14,1),reg_io8")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU09:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr8,rcvrSysReg(6,8,1),reg_io8")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU09:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr8,rcvrSysReg(6,2,1),reg_io8")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU09:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar8")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar8")   
	field(FLNK, "HU1:CBPM:HU09:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU09:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar8")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU09:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU09:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU09:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU09:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU09:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU09:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU09:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU09:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU09:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU09:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU09:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU09:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU09:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU09:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU09:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU09:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU09:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr8,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU09:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar8")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU09:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU09:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar8")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU09:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU09:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar8")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU09:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU09:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar8")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU09:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU09:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar8")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU09:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU09:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar8")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU09:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU09:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar8")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU09:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU09:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar8")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU09:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU09:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar8")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU09:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar8")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU09:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU09:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar8")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU09:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU09:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar8")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU09:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU09:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar8")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU09:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU09:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar8")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU09:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU09:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar8")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU09:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU09:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar8")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU09:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU09:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar8")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU09:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU09:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll8,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU09:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU09:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU09:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU09:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU09:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU09:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU09:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU09:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU09:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU09:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU09:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU09:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU09:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU09:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU09:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU09:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU09:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU09:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU09:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU09:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU09:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU09:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU09:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU09:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU09:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU09:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU09:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU09:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU09:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU09:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU09:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU09:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU09:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU09:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU09:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU09:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU09:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU09:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU09:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU09:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU09:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU09:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU09:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU09:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU09:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU09:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU09:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU09:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU09:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU09:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU09:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU09:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU09:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU09:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU09:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU09:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU09:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU09:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU09:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU09:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU09:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU09:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU09:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU09:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU09:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU09:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU09:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU09:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU09:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU09:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU09:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU09:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU09:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU09:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU09:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU09:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU09:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU09:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU09:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU09:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU09:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU09:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU09:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU09:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU09:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU09:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU09:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU09:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU09:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU09:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU09:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU09:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU09:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_CHIP_PIN initializes HU1:CBPM:HU09:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_CHIP_SPI initializes HU1:CBPM:HU09:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_RST_CLKS initializes HU1:CBPM:HU09:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_RST_BIAS initializes HU1:CBPM:HU09:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_RST_PFD initializes HU1:CBPM:HU09:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_RST_CP initializes HU1:CBPM:HU09:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_RST_REF initializes HU1:CBPM:HU09:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_RST_VCO initializes HU1:CBPM:HU09:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_RST_IO initializes HU1:CBPM:HU09:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_FRAC_RST initializes HU1:CBPM:HU09:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_FRACBUFF_RST initializes HU1:CBPM:HU09:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_FRACBYP initializes HU1:CBPM:HU09:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_AUTOSEED initializes HU1:CBPM:HU09:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_FSK initializes HU1:CBPM:HU09:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_REFCLK initializes HU1:CBPM:HU09:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_INVCLK initializes HU1:CBPM:HU09:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_ILKD initializes HU1:CBPM:HU09:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_ASYMW initializes HU1:CBPM:HU09:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_ASYMWUP initializes HU1:CBPM:HU09:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_ROSC initializes HU1:CBPM:HU09:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_ROSCTEST initializes HU1:CBPM:HU09:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_CSP initializes HU1:CBPM:HU09:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_BIAS_EN initializes HU1:CBPM:HU09:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_CP_EN initializes HU1:CBPM:HU09:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_PFD_EN initializes HU1:CBPM:HU09:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_REF_EN initializes HU1:CBPM:HU09:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_VCO_EN initializes HU1:CBPM:HU09:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_GPIO_EN initializes HU1:CBPM:HU09:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_LD_EN initializes HU1:CBPM:HU09:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_CLKDIG_EN initializes HU1:CBPM:HU09:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_DIV_EN initializes HU1:CBPM:HU09:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_DCYC_EN initializes HU1:CBPM:HU09:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_REFDIG_EN initializes HU1:CBPM:HU09:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_RDIVDIG_EN initializes HU1:CBPM:HU09:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_VCOSPI_EN initializes HU1:CBPM:HU09:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_PHASSEL initializes HU1:CBPM:HU09:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_PFDUP_EN initializes HU1:CBPM:HU09:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_PFDDN_EN initializes HU1:CBPM:HU09:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_PFDLD_EN initializes HU1:CBPM:HU09:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_PFDUP initializes HU1:CBPM:HU09:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_PFDDN initializes HU1:CBPM:HU09:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU09:PLL_PFDMUTE initializes HU1:CBPM:HU09:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU09:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU09:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU09:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU09:PLL_CSPCORR initializes HU1:CBPM:HU09:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU09:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU09:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU09:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU09:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU09:PLL_LKDW initializes HU1:CBPM:HU09:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU09:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU09:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU09:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU09:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU09:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU09:PLL_PFDDLY initializes HU1:CBPM:HU09:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU09:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU09:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU09:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU09:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU09:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU09:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU09:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU09:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU09:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU09:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU09:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU09:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU09:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU09:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU09:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU09:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU09:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU09:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU09:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU09:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU09:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU09:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU09:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU09:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU09:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU09:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU09:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU09:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU09:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU09:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU09:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU09:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU09:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU09:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU09:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU09:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU09:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU09:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU09:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU09:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU09:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU09:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU09:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU09:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU09:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU09:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU09:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU09:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU09:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU09:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU09:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU09:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU09:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU09:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU09:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU09:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU09:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU09:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU09:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU09:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU09:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU09:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU09:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU09:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU09:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU09:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU09:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU09:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU09:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU09:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU09:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU09:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU09:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU09:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU09:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU09:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU09:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU09:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU09:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU09:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU09:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU09:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU09:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU09:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU09:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU09:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU09:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU09:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU09:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU09:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU09:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU09:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU09:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU09:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU09:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU09:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU09:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU09:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU09:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU09:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU09:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU09:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU09:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU09:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU09:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU09:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU09:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU09:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU09:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU09:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU09:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU09:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU09:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU09:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU09:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU09:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU09:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU09:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU09:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU09:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU09:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU09:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU09:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU09:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU09:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU09:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU09:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU09:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU09:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU09:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU09:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU09:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU09:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU09:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU09:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU09:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU09:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU09:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU09:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU09:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU09:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU09:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU09:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU09:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU09:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU09:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU09:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU09:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU09:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU10:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar9")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU10:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU10:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc9,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU10:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg9,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU10:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU10:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU10:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU10:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU10:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU10:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr9,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU10:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU10:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU10:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU10:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU10:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU10:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU10:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr9,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU10:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU10:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU10:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU10:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU10:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU10:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU10:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr9,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU10:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU10:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU10:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU10:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU10:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU10:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU10:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr9,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU10:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU10:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU10:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU10:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU10:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar9")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU10:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar9")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU10:ATTY")  
}   

record(longin, "HU1:CBPM:HU10:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar9")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU10:ATTREF")  
}   

record(longin, "HU1:CBPM:HU10:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar9")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU10:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU10:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar9")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU10:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar9")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU10:PS_STA")
}

record(bi, "HU1:CBPM:HU10:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar9")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU10:LO_LTCH")
}

record(bi, "HU1:CBPM:HU10:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar9")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU10:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr9,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU10:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar9")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU10:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr9,rcvrSysReg(8,14,1),reg_io9")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU10:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr9,rcvrSysReg(6,8,1),reg_io9")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU10:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr9,rcvrSysReg(6,2,1),reg_io9")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU10:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar9")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar9")   
	field(FLNK, "HU1:CBPM:HU10:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU10:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar9")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU10:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU10:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU10:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU10:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU10:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU10:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU10:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU10:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU10:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU10:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU10:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU10:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU10:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU10:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU10:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU10:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU10:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr9,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU10:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar9")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU10:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU10:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar9")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU10:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU10:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar9")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU10:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU10:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar9")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU10:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU10:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar9")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU10:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU10:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar9")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU10:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU10:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar9")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU10:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU10:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar9")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU10:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU10:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar9")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU10:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar9")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU10:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU10:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar9")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU10:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU10:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar9")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU10:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU10:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar9")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU10:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU10:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar9")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU10:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU10:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar9")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU10:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU10:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar9")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU10:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU10:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar9")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU10:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU10:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll9,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU10:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU10:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU10:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU10:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU10:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU10:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU10:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU10:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU10:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU10:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU10:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU10:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU10:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU10:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU10:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU10:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU10:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU10:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU10:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU10:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU10:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU10:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU10:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU10:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU10:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU10:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU10:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU10:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU10:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU10:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU10:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU10:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU10:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU10:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU10:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU10:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU10:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU10:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU10:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU10:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU10:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU10:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU10:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU10:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU10:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU10:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU10:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU10:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU10:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU10:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU10:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU10:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU10:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU10:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU10:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU10:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU10:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU10:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU10:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU10:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU10:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU10:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU10:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU10:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU10:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU10:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU10:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU10:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU10:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU10:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU10:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU10:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU10:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU10:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU10:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU10:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU10:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU10:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU10:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU10:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU10:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU10:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU10:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU10:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU10:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU10:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU10:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU10:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU10:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU10:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU10:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU10:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU10:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_CHIP_PIN initializes HU1:CBPM:HU10:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_CHIP_SPI initializes HU1:CBPM:HU10:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_RST_CLKS initializes HU1:CBPM:HU10:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_RST_BIAS initializes HU1:CBPM:HU10:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_RST_PFD initializes HU1:CBPM:HU10:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_RST_CP initializes HU1:CBPM:HU10:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_RST_REF initializes HU1:CBPM:HU10:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_RST_VCO initializes HU1:CBPM:HU10:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_RST_IO initializes HU1:CBPM:HU10:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_FRAC_RST initializes HU1:CBPM:HU10:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_FRACBUFF_RST initializes HU1:CBPM:HU10:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_FRACBYP initializes HU1:CBPM:HU10:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_AUTOSEED initializes HU1:CBPM:HU10:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_FSK initializes HU1:CBPM:HU10:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_REFCLK initializes HU1:CBPM:HU10:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_INVCLK initializes HU1:CBPM:HU10:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_ILKD initializes HU1:CBPM:HU10:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_ASYMW initializes HU1:CBPM:HU10:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_ASYMWUP initializes HU1:CBPM:HU10:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_ROSC initializes HU1:CBPM:HU10:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_ROSCTEST initializes HU1:CBPM:HU10:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_CSP initializes HU1:CBPM:HU10:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_BIAS_EN initializes HU1:CBPM:HU10:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_CP_EN initializes HU1:CBPM:HU10:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_PFD_EN initializes HU1:CBPM:HU10:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_REF_EN initializes HU1:CBPM:HU10:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_VCO_EN initializes HU1:CBPM:HU10:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_GPIO_EN initializes HU1:CBPM:HU10:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_LD_EN initializes HU1:CBPM:HU10:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_CLKDIG_EN initializes HU1:CBPM:HU10:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_DIV_EN initializes HU1:CBPM:HU10:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_DCYC_EN initializes HU1:CBPM:HU10:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_REFDIG_EN initializes HU1:CBPM:HU10:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_RDIVDIG_EN initializes HU1:CBPM:HU10:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_VCOSPI_EN initializes HU1:CBPM:HU10:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_PHASSEL initializes HU1:CBPM:HU10:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_PFDUP_EN initializes HU1:CBPM:HU10:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_PFDDN_EN initializes HU1:CBPM:HU10:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_PFDLD_EN initializes HU1:CBPM:HU10:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_PFDUP initializes HU1:CBPM:HU10:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_PFDDN initializes HU1:CBPM:HU10:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU10:PLL_PFDMUTE initializes HU1:CBPM:HU10:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU10:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU10:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU10:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU10:PLL_CSPCORR initializes HU1:CBPM:HU10:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU10:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU10:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU10:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU10:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU10:PLL_LKDW initializes HU1:CBPM:HU10:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU10:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU10:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU10:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU10:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU10:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU10:PLL_PFDDLY initializes HU1:CBPM:HU10:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU10:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU10:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU10:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU10:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU10:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU10:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU10:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU10:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU10:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU10:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU10:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU10:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU10:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU10:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU10:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU10:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU10:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU10:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU10:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU10:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU10:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU10:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU10:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU10:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU10:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU10:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU10:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU10:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU10:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU10:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU10:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU10:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU10:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU10:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU10:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU10:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU10:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU10:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU10:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU10:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU10:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU10:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU10:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU10:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU10:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU10:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU10:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU10:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU10:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU10:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU10:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU10:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU10:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU10:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU10:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU10:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU10:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU10:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU10:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU10:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU10:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU10:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU10:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU10:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU10:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU10:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU10:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU10:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU10:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU10:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU10:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU10:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU10:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU10:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU10:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU10:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU10:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU10:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU10:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU10:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU10:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU10:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU10:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU10:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU10:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU10:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU10:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU10:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU10:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU10:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU10:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU10:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU10:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU10:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU10:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU10:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU10:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU10:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU10:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU10:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU10:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU10:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU10:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU10:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU10:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU10:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU10:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU10:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU10:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU10:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU10:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU10:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU10:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU10:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU10:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU10:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU10:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU10:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU10:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU10:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU10:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU10:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU10:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU10:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU10:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU10:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU10:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU10:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU10:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU10:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU10:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU10:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU10:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU10:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU10:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU10:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU10:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU10:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU10:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU10:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU10:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU10:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU10:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU10:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU10:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU10:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU10:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU10:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU10:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU11:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar10")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU11:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU11:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc10,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU11:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg10,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU11:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU11:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU11:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU11:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU11:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU11:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr10,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU11:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU11:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU11:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU11:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU11:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU11:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU11:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr10,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU11:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU11:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU11:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU11:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU11:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU11:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU11:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr10,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU11:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU11:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU11:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU11:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU11:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU11:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU11:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr10,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU11:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU11:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU11:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU11:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU11:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar10")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU11:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar10")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU11:ATTY")  
}   

record(longin, "HU1:CBPM:HU11:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar10")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU11:ATTREF")  
}   

record(longin, "HU1:CBPM:HU11:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar10")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU11:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU11:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar10")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU11:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar10")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU11:PS_STA")
}

record(bi, "HU1:CBPM:HU11:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar10")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU11:LO_LTCH")
}

record(bi, "HU1:CBPM:HU11:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar10")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU11:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr10,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU11:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar10")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU11:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr10,rcvrSysReg(8,14,1),reg_io10")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU11:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr10,rcvrSysReg(6,8,1),reg_io10")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU11:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr10,rcvrSysReg(6,2,1),reg_io10")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU11:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar10")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar10")   
	field(FLNK, "HU1:CBPM:HU11:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU11:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar10")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU11:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU11:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU11:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU11:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU11:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU11:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU11:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU11:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU11:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU11:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU11:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU11:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU11:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU11:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU11:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU11:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU11:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr10,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU11:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar10")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU11:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU11:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar10")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU11:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU11:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar10")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU11:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU11:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar10")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU11:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU11:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar10")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU11:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU11:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar10")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU11:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU11:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar10")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU11:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU11:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar10")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU11:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU11:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar10")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU11:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar10")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU11:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU11:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar10")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU11:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU11:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar10")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU11:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU11:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar10")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU11:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU11:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar10")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU11:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU11:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar10")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU11:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU11:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar10")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU11:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU11:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar10")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU11:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU11:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll10,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU11:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU11:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU11:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU11:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU11:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU11:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU11:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU11:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU11:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU11:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU11:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU11:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU11:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU11:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU11:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU11:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU11:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU11:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU11:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU11:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU11:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU11:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU11:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU11:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU11:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU11:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU11:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU11:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU11:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU11:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU11:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU11:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU11:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU11:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU11:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU11:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU11:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU11:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU11:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU11:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU11:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU11:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU11:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU11:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU11:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU11:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU11:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU11:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU11:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU11:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU11:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU11:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU11:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU11:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU11:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU11:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU11:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU11:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU11:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU11:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU11:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU11:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU11:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU11:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU11:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU11:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU11:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU11:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU11:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU11:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU11:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU11:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU11:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU11:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU11:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU11:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU11:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU11:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU11:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU11:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU11:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU11:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU11:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU11:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU11:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU11:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU11:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU11:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU11:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU11:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU11:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU11:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU11:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_CHIP_PIN initializes HU1:CBPM:HU11:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_CHIP_SPI initializes HU1:CBPM:HU11:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_RST_CLKS initializes HU1:CBPM:HU11:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_RST_BIAS initializes HU1:CBPM:HU11:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_RST_PFD initializes HU1:CBPM:HU11:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_RST_CP initializes HU1:CBPM:HU11:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_RST_REF initializes HU1:CBPM:HU11:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_RST_VCO initializes HU1:CBPM:HU11:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_RST_IO initializes HU1:CBPM:HU11:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_FRAC_RST initializes HU1:CBPM:HU11:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_FRACBUFF_RST initializes HU1:CBPM:HU11:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_FRACBYP initializes HU1:CBPM:HU11:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_AUTOSEED initializes HU1:CBPM:HU11:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_FSK initializes HU1:CBPM:HU11:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_REFCLK initializes HU1:CBPM:HU11:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_INVCLK initializes HU1:CBPM:HU11:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_ILKD initializes HU1:CBPM:HU11:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_ASYMW initializes HU1:CBPM:HU11:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_ASYMWUP initializes HU1:CBPM:HU11:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_ROSC initializes HU1:CBPM:HU11:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_ROSCTEST initializes HU1:CBPM:HU11:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_CSP initializes HU1:CBPM:HU11:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_BIAS_EN initializes HU1:CBPM:HU11:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_CP_EN initializes HU1:CBPM:HU11:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_PFD_EN initializes HU1:CBPM:HU11:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_REF_EN initializes HU1:CBPM:HU11:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_VCO_EN initializes HU1:CBPM:HU11:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_GPIO_EN initializes HU1:CBPM:HU11:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_LD_EN initializes HU1:CBPM:HU11:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_CLKDIG_EN initializes HU1:CBPM:HU11:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_DIV_EN initializes HU1:CBPM:HU11:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_DCYC_EN initializes HU1:CBPM:HU11:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_REFDIG_EN initializes HU1:CBPM:HU11:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_RDIVDIG_EN initializes HU1:CBPM:HU11:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_VCOSPI_EN initializes HU1:CBPM:HU11:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_PHASSEL initializes HU1:CBPM:HU11:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_PFDUP_EN initializes HU1:CBPM:HU11:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_PFDDN_EN initializes HU1:CBPM:HU11:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_PFDLD_EN initializes HU1:CBPM:HU11:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_PFDUP initializes HU1:CBPM:HU11:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_PFDDN initializes HU1:CBPM:HU11:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU11:PLL_PFDMUTE initializes HU1:CBPM:HU11:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU11:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU11:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU11:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU11:PLL_CSPCORR initializes HU1:CBPM:HU11:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU11:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU11:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU11:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU11:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU11:PLL_LKDW initializes HU1:CBPM:HU11:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU11:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU11:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU11:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU11:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU11:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU11:PLL_PFDDLY initializes HU1:CBPM:HU11:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU11:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU11:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU11:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU11:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU11:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU11:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU11:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU11:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU11:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU11:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU11:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU11:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU11:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU11:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU11:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU11:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU11:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU11:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU11:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU11:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU11:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU11:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU11:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU11:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU11:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU11:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU11:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU11:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU11:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU11:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU11:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU11:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU11:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU11:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU11:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU11:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU11:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU11:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU11:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU11:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU11:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU11:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU11:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU11:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU11:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU11:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU11:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU11:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU11:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU11:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU11:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU11:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU11:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU11:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU11:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU11:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU11:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU11:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU11:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU11:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU11:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU11:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU11:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU11:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU11:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU11:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU11:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU11:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU11:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU11:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU11:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU11:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU11:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU11:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU11:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU11:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU11:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU11:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU11:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU11:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU11:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU11:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU11:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU11:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU11:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU11:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU11:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU11:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU11:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU11:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU11:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU11:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU11:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU11:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU11:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU11:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU11:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU11:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU11:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU11:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU11:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU11:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU11:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU11:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU11:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU11:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU11:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU11:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU11:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU11:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU11:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU11:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU11:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU11:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU11:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU11:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU11:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU11:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU11:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU11:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU11:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU11:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU11:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU11:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU11:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU11:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU11:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU11:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU11:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU11:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU11:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU11:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU11:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU11:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU11:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU11:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU11:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU11:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU11:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU11:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU11:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU11:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU11:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU11:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU11:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU11:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU11:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU11:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU11:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU12:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar11")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU12:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU12:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc11,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU12:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg11,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU12:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU12:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU12:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU12:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU12:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU12:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr11,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU12:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU12:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU12:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU12:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU12:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU12:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU12:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr11,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU12:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU12:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU12:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU12:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU12:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU12:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU12:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr11,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU12:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU12:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU12:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU12:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU12:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU12:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU12:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr11,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU12:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU12:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU12:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU12:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU12:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar11")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU12:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar11")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU12:ATTY")  
}   

record(longin, "HU1:CBPM:HU12:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar11")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU12:ATTREF")  
}   

record(longin, "HU1:CBPM:HU12:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar11")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU12:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU12:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar11")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU12:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar11")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU12:PS_STA")
}

record(bi, "HU1:CBPM:HU12:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar11")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU12:LO_LTCH")
}

record(bi, "HU1:CBPM:HU12:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar11")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU12:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr11,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU12:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar11")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU12:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr11,rcvrSysReg(8,14,1),reg_io11")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU12:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr11,rcvrSysReg(6,8,1),reg_io11")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU12:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr11,rcvrSysReg(6,2,1),reg_io11")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU12:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar11")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar11")   
	field(FLNK, "HU1:CBPM:HU12:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU12:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar11")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU12:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU12:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU12:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU12:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU12:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU12:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU12:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU12:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU12:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU12:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU12:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU12:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU12:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU12:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU12:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU12:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU12:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr11,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU12:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar11")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU12:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU12:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar11")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU12:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU12:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar11")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU12:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU12:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar11")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU12:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU12:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar11")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU12:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU12:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar11")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU12:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU12:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar11")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU12:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU12:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar11")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU12:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU12:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar11")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU12:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar11")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU12:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU12:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar11")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU12:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU12:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar11")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU12:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU12:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar11")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU12:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU12:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar11")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU12:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU12:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar11")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU12:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU12:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar11")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU12:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU12:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar11")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU12:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU12:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll11,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU12:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU12:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU12:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU12:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU12:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU12:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU12:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU12:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU12:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU12:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU12:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU12:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU12:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU12:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU12:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU12:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU12:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU12:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU12:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU12:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU12:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU12:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU12:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU12:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU12:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU12:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU12:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU12:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU12:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU12:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU12:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU12:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU12:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU12:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU12:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU12:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU12:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU12:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU12:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU12:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU12:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU12:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU12:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU12:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU12:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU12:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU12:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU12:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU12:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU12:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU12:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU12:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU12:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU12:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU12:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU12:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU12:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU12:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU12:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU12:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU12:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU12:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU12:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU12:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU12:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU12:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU12:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU12:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU12:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU12:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU12:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU12:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU12:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU12:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU12:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU12:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU12:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU12:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU12:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU12:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU12:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU12:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU12:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU12:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU12:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU12:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU12:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU12:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU12:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU12:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU12:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU12:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU12:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_CHIP_PIN initializes HU1:CBPM:HU12:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_CHIP_SPI initializes HU1:CBPM:HU12:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_RST_CLKS initializes HU1:CBPM:HU12:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_RST_BIAS initializes HU1:CBPM:HU12:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_RST_PFD initializes HU1:CBPM:HU12:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_RST_CP initializes HU1:CBPM:HU12:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_RST_REF initializes HU1:CBPM:HU12:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_RST_VCO initializes HU1:CBPM:HU12:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_RST_IO initializes HU1:CBPM:HU12:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_FRAC_RST initializes HU1:CBPM:HU12:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_FRACBUFF_RST initializes HU1:CBPM:HU12:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_FRACBYP initializes HU1:CBPM:HU12:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_AUTOSEED initializes HU1:CBPM:HU12:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_FSK initializes HU1:CBPM:HU12:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_REFCLK initializes HU1:CBPM:HU12:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_INVCLK initializes HU1:CBPM:HU12:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_ILKD initializes HU1:CBPM:HU12:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_ASYMW initializes HU1:CBPM:HU12:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_ASYMWUP initializes HU1:CBPM:HU12:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_ROSC initializes HU1:CBPM:HU12:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_ROSCTEST initializes HU1:CBPM:HU12:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_CSP initializes HU1:CBPM:HU12:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_BIAS_EN initializes HU1:CBPM:HU12:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_CP_EN initializes HU1:CBPM:HU12:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_PFD_EN initializes HU1:CBPM:HU12:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_REF_EN initializes HU1:CBPM:HU12:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_VCO_EN initializes HU1:CBPM:HU12:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_GPIO_EN initializes HU1:CBPM:HU12:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_LD_EN initializes HU1:CBPM:HU12:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_CLKDIG_EN initializes HU1:CBPM:HU12:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_DIV_EN initializes HU1:CBPM:HU12:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_DCYC_EN initializes HU1:CBPM:HU12:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_REFDIG_EN initializes HU1:CBPM:HU12:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_RDIVDIG_EN initializes HU1:CBPM:HU12:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_VCOSPI_EN initializes HU1:CBPM:HU12:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_PHASSEL initializes HU1:CBPM:HU12:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_PFDUP_EN initializes HU1:CBPM:HU12:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_PFDDN_EN initializes HU1:CBPM:HU12:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_PFDLD_EN initializes HU1:CBPM:HU12:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_PFDUP initializes HU1:CBPM:HU12:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_PFDDN initializes HU1:CBPM:HU12:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU12:PLL_PFDMUTE initializes HU1:CBPM:HU12:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU12:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU12:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU12:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU12:PLL_CSPCORR initializes HU1:CBPM:HU12:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU12:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU12:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU12:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU12:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU12:PLL_LKDW initializes HU1:CBPM:HU12:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU12:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU12:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU12:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU12:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU12:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU12:PLL_PFDDLY initializes HU1:CBPM:HU12:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU12:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU12:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU12:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU12:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU12:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU12:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU12:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU12:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU12:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU12:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU12:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU12:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU12:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU12:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU12:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU12:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU12:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU12:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU12:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU12:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU12:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU12:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU12:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU12:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU12:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU12:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU12:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU12:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU12:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU12:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU12:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU12:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU12:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU12:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU12:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU12:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU12:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU12:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU12:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU12:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU12:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU12:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU12:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU12:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU12:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU12:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU12:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU12:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU12:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU12:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU12:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU12:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU12:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU12:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU12:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU12:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU12:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU12:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU12:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU12:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU12:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU12:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU12:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU12:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU12:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU12:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU12:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU12:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU12:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU12:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU12:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU12:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU12:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU12:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU12:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU12:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU12:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU12:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU12:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU12:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU12:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU12:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU12:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU12:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU12:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU12:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU12:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU12:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU12:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU12:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU12:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU12:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU12:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU12:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU12:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU12:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU12:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU12:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU12:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU12:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU12:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU12:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU12:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU12:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU12:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU12:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU12:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU12:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU12:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU12:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU12:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU12:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU12:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU12:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU12:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU12:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU12:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU12:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU12:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU12:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU12:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU12:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU12:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU12:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU12:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU12:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU12:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU12:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU12:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU12:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU12:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU12:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU12:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU12:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU12:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU12:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU12:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU12:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU12:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU12:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU12:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU12:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU12:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU12:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU12:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU12:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU12:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU12:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU12:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU13:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar12")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU13:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU13:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc12,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU13:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg12,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU13:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU13:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU13:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU13:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU13:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU13:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr12,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU13:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU13:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU13:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU13:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU13:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU13:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU13:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr12,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU13:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU13:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU13:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU13:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU13:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU13:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU13:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr12,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU13:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU13:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU13:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU13:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU13:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU13:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU13:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr12,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU13:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU13:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU13:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU13:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU13:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar12")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU13:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar12")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU13:ATTY")  
}   

record(longin, "HU1:CBPM:HU13:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar12")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU13:ATTREF")  
}   

record(longin, "HU1:CBPM:HU13:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar12")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU13:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU13:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar12")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU13:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar12")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU13:PS_STA")
}

record(bi, "HU1:CBPM:HU13:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar12")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU13:LO_LTCH")
}

record(bi, "HU1:CBPM:HU13:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar12")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU13:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr12,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU13:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar12")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU13:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr12,rcvrSysReg(8,14,1),reg_io12")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU13:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr12,rcvrSysReg(6,8,1),reg_io12")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU13:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr12,rcvrSysReg(6,2,1),reg_io12")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU13:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar12")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar12")   
	field(FLNK, "HU1:CBPM:HU13:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU13:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar12")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU13:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU13:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU13:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU13:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU13:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU13:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU13:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU13:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU13:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU13:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU13:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU13:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU13:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU13:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU13:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU13:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU13:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr12,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU13:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar12")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU13:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU13:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar12")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU13:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU13:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar12")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU13:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU13:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar12")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU13:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU13:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar12")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU13:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU13:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar12")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU13:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU13:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar12")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU13:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU13:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar12")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU13:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU13:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar12")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU13:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar12")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU13:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU13:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar12")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU13:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU13:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar12")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU13:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU13:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar12")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU13:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU13:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar12")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU13:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU13:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar12")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU13:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU13:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar12")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU13:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU13:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar12")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU13:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU13:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll12,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU13:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU13:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU13:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU13:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU13:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU13:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU13:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU13:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU13:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU13:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU13:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU13:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU13:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU13:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU13:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU13:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU13:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU13:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU13:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU13:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU13:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU13:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU13:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU13:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU13:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU13:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU13:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU13:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU13:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU13:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU13:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU13:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU13:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU13:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU13:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU13:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU13:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU13:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU13:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU13:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU13:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU13:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU13:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU13:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU13:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU13:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU13:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU13:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU13:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU13:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU13:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU13:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU13:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU13:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU13:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU13:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU13:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU13:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU13:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU13:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU13:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU13:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU13:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU13:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU13:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU13:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU13:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU13:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU13:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU13:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU13:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU13:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU13:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU13:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU13:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU13:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU13:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU13:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU13:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU13:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU13:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU13:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU13:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU13:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU13:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU13:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU13:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU13:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU13:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU13:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU13:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU13:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU13:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_CHIP_PIN initializes HU1:CBPM:HU13:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_CHIP_SPI initializes HU1:CBPM:HU13:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_RST_CLKS initializes HU1:CBPM:HU13:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_RST_BIAS initializes HU1:CBPM:HU13:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_RST_PFD initializes HU1:CBPM:HU13:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_RST_CP initializes HU1:CBPM:HU13:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_RST_REF initializes HU1:CBPM:HU13:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_RST_VCO initializes HU1:CBPM:HU13:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_RST_IO initializes HU1:CBPM:HU13:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_FRAC_RST initializes HU1:CBPM:HU13:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_FRACBUFF_RST initializes HU1:CBPM:HU13:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_FRACBYP initializes HU1:CBPM:HU13:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_AUTOSEED initializes HU1:CBPM:HU13:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_FSK initializes HU1:CBPM:HU13:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_REFCLK initializes HU1:CBPM:HU13:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_INVCLK initializes HU1:CBPM:HU13:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_ILKD initializes HU1:CBPM:HU13:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_ASYMW initializes HU1:CBPM:HU13:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_ASYMWUP initializes HU1:CBPM:HU13:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_ROSC initializes HU1:CBPM:HU13:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_ROSCTEST initializes HU1:CBPM:HU13:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_CSP initializes HU1:CBPM:HU13:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_BIAS_EN initializes HU1:CBPM:HU13:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_CP_EN initializes HU1:CBPM:HU13:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_PFD_EN initializes HU1:CBPM:HU13:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_REF_EN initializes HU1:CBPM:HU13:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_VCO_EN initializes HU1:CBPM:HU13:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_GPIO_EN initializes HU1:CBPM:HU13:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_LD_EN initializes HU1:CBPM:HU13:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_CLKDIG_EN initializes HU1:CBPM:HU13:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_DIV_EN initializes HU1:CBPM:HU13:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_DCYC_EN initializes HU1:CBPM:HU13:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_REFDIG_EN initializes HU1:CBPM:HU13:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_RDIVDIG_EN initializes HU1:CBPM:HU13:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_VCOSPI_EN initializes HU1:CBPM:HU13:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_PHASSEL initializes HU1:CBPM:HU13:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_PFDUP_EN initializes HU1:CBPM:HU13:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_PFDDN_EN initializes HU1:CBPM:HU13:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_PFDLD_EN initializes HU1:CBPM:HU13:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_PFDUP initializes HU1:CBPM:HU13:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_PFDDN initializes HU1:CBPM:HU13:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU13:PLL_PFDMUTE initializes HU1:CBPM:HU13:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU13:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU13:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU13:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU13:PLL_CSPCORR initializes HU1:CBPM:HU13:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU13:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU13:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU13:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU13:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU13:PLL_LKDW initializes HU1:CBPM:HU13:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU13:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU13:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU13:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU13:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU13:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU13:PLL_PFDDLY initializes HU1:CBPM:HU13:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU13:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU13:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU13:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU13:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU13:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU13:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU13:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU13:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU13:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU13:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU13:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU13:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU13:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU13:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU13:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU13:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU13:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU13:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU13:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU13:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU13:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU13:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU13:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU13:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU13:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU13:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU13:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU13:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU13:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU13:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU13:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU13:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU13:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU13:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU13:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU13:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU13:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU13:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU13:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU13:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU13:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU13:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU13:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU13:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU13:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU13:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU13:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU13:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU13:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU13:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU13:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU13:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU13:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU13:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU13:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU13:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU13:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU13:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU13:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU13:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU13:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU13:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU13:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU13:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU13:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU13:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU13:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU13:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU13:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU13:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU13:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU13:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU13:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU13:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU13:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU13:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU13:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU13:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU13:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU13:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU13:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU13:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU13:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU13:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU13:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU13:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU13:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU13:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU13:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU13:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU13:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU13:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU13:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU13:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU13:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU13:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU13:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU13:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU13:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU13:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU13:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU13:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU13:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU13:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU13:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU13:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU13:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU13:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU13:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU13:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU13:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU13:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU13:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU13:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU13:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU13:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU13:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU13:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU13:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU13:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU13:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU13:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU13:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU13:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU13:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU13:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU13:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU13:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU13:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU13:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU13:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU13:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU13:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU13:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU13:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU13:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU13:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU13:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU13:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU13:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU13:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU13:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU13:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU13:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU13:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU13:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU13:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU13:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU13:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU14:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar13")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU14:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU14:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc13,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU14:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg13,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU14:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU14:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU14:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU14:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU14:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU14:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr13,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU14:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU14:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU14:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU14:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU14:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU14:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU14:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr13,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU14:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU14:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU14:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU14:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU14:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU14:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU14:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr13,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU14:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU14:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU14:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU14:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU14:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU14:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU14:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr13,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU14:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU14:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU14:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU14:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU14:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar13")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU14:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar13")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU14:ATTY")  
}   

record(longin, "HU1:CBPM:HU14:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar13")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU14:ATTREF")  
}   

record(longin, "HU1:CBPM:HU14:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar13")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU14:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU14:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar13")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU14:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar13")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU14:PS_STA")
}

record(bi, "HU1:CBPM:HU14:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar13")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU14:LO_LTCH")
}

record(bi, "HU1:CBPM:HU14:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar13")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU14:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr13,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU14:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar13")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU14:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr13,rcvrSysReg(8,14,1),reg_io13")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU14:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr13,rcvrSysReg(6,8,1),reg_io13")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU14:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr13,rcvrSysReg(6,2,1),reg_io13")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU14:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar13")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar13")   
	field(FLNK, "HU1:CBPM:HU14:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU14:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar13")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU14:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU14:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU14:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU14:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU14:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU14:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU14:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU14:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU14:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU14:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU14:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU14:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU14:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU14:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU14:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU14:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU14:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr13,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU14:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar13")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU14:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU14:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar13")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU14:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU14:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar13")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU14:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU14:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar13")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU14:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU14:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar13")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU14:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU14:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar13")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU14:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU14:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar13")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU14:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU14:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar13")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU14:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU14:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar13")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU14:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar13")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU14:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU14:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar13")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU14:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU14:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar13")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU14:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU14:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar13")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU14:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU14:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar13")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU14:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU14:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar13")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU14:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU14:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar13")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU14:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU14:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar13")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU14:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU14:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll13,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU14:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU14:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU14:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU14:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU14:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU14:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU14:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU14:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU14:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU14:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU14:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU14:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU14:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU14:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU14:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU14:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU14:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU14:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU14:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU14:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU14:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU14:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU14:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU14:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU14:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU14:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU14:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU14:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU14:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU14:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU14:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU14:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU14:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU14:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU14:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU14:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU14:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU14:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU14:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU14:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU14:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU14:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU14:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU14:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU14:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU14:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU14:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU14:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU14:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU14:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU14:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU14:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU14:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU14:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU14:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU14:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU14:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU14:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU14:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU14:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU14:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU14:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU14:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU14:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU14:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU14:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU14:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU14:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU14:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU14:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU14:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU14:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU14:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU14:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU14:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU14:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU14:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU14:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU14:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU14:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU14:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU14:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU14:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU14:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU14:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU14:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU14:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU14:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU14:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU14:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU14:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU14:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU14:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_CHIP_PIN initializes HU1:CBPM:HU14:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_CHIP_SPI initializes HU1:CBPM:HU14:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_RST_CLKS initializes HU1:CBPM:HU14:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_RST_BIAS initializes HU1:CBPM:HU14:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_RST_PFD initializes HU1:CBPM:HU14:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_RST_CP initializes HU1:CBPM:HU14:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_RST_REF initializes HU1:CBPM:HU14:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_RST_VCO initializes HU1:CBPM:HU14:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_RST_IO initializes HU1:CBPM:HU14:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_FRAC_RST initializes HU1:CBPM:HU14:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_FRACBUFF_RST initializes HU1:CBPM:HU14:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_FRACBYP initializes HU1:CBPM:HU14:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_AUTOSEED initializes HU1:CBPM:HU14:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_FSK initializes HU1:CBPM:HU14:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_REFCLK initializes HU1:CBPM:HU14:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_INVCLK initializes HU1:CBPM:HU14:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_ILKD initializes HU1:CBPM:HU14:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_ASYMW initializes HU1:CBPM:HU14:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_ASYMWUP initializes HU1:CBPM:HU14:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_ROSC initializes HU1:CBPM:HU14:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_ROSCTEST initializes HU1:CBPM:HU14:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_CSP initializes HU1:CBPM:HU14:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_BIAS_EN initializes HU1:CBPM:HU14:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_CP_EN initializes HU1:CBPM:HU14:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_PFD_EN initializes HU1:CBPM:HU14:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_REF_EN initializes HU1:CBPM:HU14:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_VCO_EN initializes HU1:CBPM:HU14:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_GPIO_EN initializes HU1:CBPM:HU14:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_LD_EN initializes HU1:CBPM:HU14:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_CLKDIG_EN initializes HU1:CBPM:HU14:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_DIV_EN initializes HU1:CBPM:HU14:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_DCYC_EN initializes HU1:CBPM:HU14:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_REFDIG_EN initializes HU1:CBPM:HU14:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_RDIVDIG_EN initializes HU1:CBPM:HU14:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_VCOSPI_EN initializes HU1:CBPM:HU14:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_PHASSEL initializes HU1:CBPM:HU14:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_PFDUP_EN initializes HU1:CBPM:HU14:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_PFDDN_EN initializes HU1:CBPM:HU14:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_PFDLD_EN initializes HU1:CBPM:HU14:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_PFDUP initializes HU1:CBPM:HU14:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_PFDDN initializes HU1:CBPM:HU14:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU14:PLL_PFDMUTE initializes HU1:CBPM:HU14:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU14:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU14:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU14:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU14:PLL_CSPCORR initializes HU1:CBPM:HU14:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU14:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU14:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU14:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU14:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU14:PLL_LKDW initializes HU1:CBPM:HU14:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU14:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU14:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU14:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU14:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU14:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU14:PLL_PFDDLY initializes HU1:CBPM:HU14:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU14:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU14:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU14:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU14:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU14:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU14:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU14:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU14:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU14:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU14:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU14:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU14:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU14:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU14:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU14:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU14:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU14:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU14:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU14:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU14:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU14:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU14:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU14:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU14:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU14:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU14:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU14:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU14:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU14:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU14:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU14:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU14:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU14:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU14:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU14:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU14:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU14:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU14:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU14:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU14:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU14:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU14:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU14:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU14:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU14:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU14:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU14:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU14:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU14:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU14:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU14:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU14:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU14:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU14:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU14:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU14:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU14:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU14:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU14:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU14:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU14:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU14:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU14:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU14:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU14:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU14:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU14:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU14:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU14:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU14:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU14:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU14:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU14:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU14:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU14:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU14:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU14:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU14:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU14:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU14:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU14:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU14:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU14:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU14:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU14:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU14:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU14:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU14:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU14:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU14:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU14:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU14:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU14:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU14:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU14:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU14:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU14:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU14:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU14:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU14:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU14:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU14:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU14:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU14:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU14:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU14:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU14:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU14:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU14:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU14:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU14:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU14:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU14:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU14:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU14:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU14:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU14:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU14:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU14:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU14:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU14:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU14:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU14:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU14:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU14:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU14:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU14:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU14:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU14:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU14:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU14:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU14:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU14:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU14:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU14:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU14:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU14:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU14:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU14:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU14:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU14:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU14:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU14:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU14:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU14:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU14:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU14:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU14:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU14:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU15:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar14")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU15:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU15:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc14,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU15:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg14,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU15:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU15:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU15:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU15:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU15:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU15:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr14,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU15:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU15:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU15:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU15:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU15:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU15:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU15:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr14,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU15:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU15:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU15:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU15:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU15:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU15:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU15:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr14,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU15:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU15:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU15:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU15:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU15:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU15:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU15:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr14,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU15:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU15:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU15:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU15:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU15:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar14")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU15:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar14")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU15:ATTY")  
}   

record(longin, "HU1:CBPM:HU15:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar14")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU15:ATTREF")  
}   

record(longin, "HU1:CBPM:HU15:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar14")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU15:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU15:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar14")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU15:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar14")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU15:PS_STA")
}

record(bi, "HU1:CBPM:HU15:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar14")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU15:LO_LTCH")
}

record(bi, "HU1:CBPM:HU15:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar14")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU15:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr14,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU15:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar14")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU15:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr14,rcvrSysReg(8,14,1),reg_io14")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU15:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr14,rcvrSysReg(6,8,1),reg_io14")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU15:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr14,rcvrSysReg(6,2,1),reg_io14")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU15:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar14")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar14")   
	field(FLNK, "HU1:CBPM:HU15:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU15:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar14")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU15:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU15:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU15:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU15:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU15:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU15:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU15:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU15:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU15:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU15:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU15:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU15:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU15:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU15:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU15:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU15:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU15:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr14,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU15:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar14")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU15:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU15:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar14")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU15:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU15:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar14")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU15:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU15:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar14")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU15:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU15:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar14")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU15:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU15:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar14")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU15:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU15:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar14")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU15:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU15:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar14")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU15:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU15:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar14")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU15:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar14")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU15:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU15:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar14")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU15:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU15:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar14")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU15:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU15:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar14")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU15:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU15:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar14")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU15:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU15:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar14")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU15:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU15:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar14")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU15:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU15:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar14")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU15:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU15:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll14,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU15:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU15:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU15:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU15:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU15:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU15:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU15:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU15:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU15:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU15:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU15:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU15:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU15:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU15:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU15:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU15:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU15:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU15:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU15:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU15:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU15:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU15:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU15:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU15:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU15:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU15:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU15:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU15:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU15:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU15:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU15:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU15:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU15:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU15:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU15:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU15:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU15:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU15:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU15:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU15:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU15:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU15:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU15:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU15:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU15:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU15:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU15:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU15:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU15:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU15:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU15:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU15:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU15:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU15:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU15:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU15:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU15:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU15:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU15:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU15:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU15:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU15:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU15:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU15:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU15:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU15:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU15:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU15:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU15:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU15:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU15:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU15:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU15:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU15:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU15:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU15:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU15:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU15:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU15:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU15:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU15:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU15:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU15:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU15:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU15:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU15:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU15:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU15:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU15:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU15:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU15:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU15:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU15:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_CHIP_PIN initializes HU1:CBPM:HU15:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_CHIP_SPI initializes HU1:CBPM:HU15:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_RST_CLKS initializes HU1:CBPM:HU15:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_RST_BIAS initializes HU1:CBPM:HU15:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_RST_PFD initializes HU1:CBPM:HU15:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_RST_CP initializes HU1:CBPM:HU15:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_RST_REF initializes HU1:CBPM:HU15:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_RST_VCO initializes HU1:CBPM:HU15:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_RST_IO initializes HU1:CBPM:HU15:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_FRAC_RST initializes HU1:CBPM:HU15:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_FRACBUFF_RST initializes HU1:CBPM:HU15:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_FRACBYP initializes HU1:CBPM:HU15:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_AUTOSEED initializes HU1:CBPM:HU15:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_FSK initializes HU1:CBPM:HU15:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_REFCLK initializes HU1:CBPM:HU15:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_INVCLK initializes HU1:CBPM:HU15:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_ILKD initializes HU1:CBPM:HU15:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_ASYMW initializes HU1:CBPM:HU15:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_ASYMWUP initializes HU1:CBPM:HU15:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_ROSC initializes HU1:CBPM:HU15:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_ROSCTEST initializes HU1:CBPM:HU15:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_CSP initializes HU1:CBPM:HU15:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_BIAS_EN initializes HU1:CBPM:HU15:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_CP_EN initializes HU1:CBPM:HU15:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_PFD_EN initializes HU1:CBPM:HU15:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_REF_EN initializes HU1:CBPM:HU15:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_VCO_EN initializes HU1:CBPM:HU15:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_GPIO_EN initializes HU1:CBPM:HU15:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_LD_EN initializes HU1:CBPM:HU15:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_CLKDIG_EN initializes HU1:CBPM:HU15:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_DIV_EN initializes HU1:CBPM:HU15:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_DCYC_EN initializes HU1:CBPM:HU15:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_REFDIG_EN initializes HU1:CBPM:HU15:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_RDIVDIG_EN initializes HU1:CBPM:HU15:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_VCOSPI_EN initializes HU1:CBPM:HU15:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_PHASSEL initializes HU1:CBPM:HU15:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_PFDUP_EN initializes HU1:CBPM:HU15:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_PFDDN_EN initializes HU1:CBPM:HU15:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_PFDLD_EN initializes HU1:CBPM:HU15:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_PFDUP initializes HU1:CBPM:HU15:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_PFDDN initializes HU1:CBPM:HU15:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU15:PLL_PFDMUTE initializes HU1:CBPM:HU15:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU15:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU15:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU15:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU15:PLL_CSPCORR initializes HU1:CBPM:HU15:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU15:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU15:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU15:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU15:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU15:PLL_LKDW initializes HU1:CBPM:HU15:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU15:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU15:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU15:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU15:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU15:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU15:PLL_PFDDLY initializes HU1:CBPM:HU15:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU15:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU15:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU15:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU15:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU15:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU15:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU15:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU15:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU15:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU15:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU15:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU15:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU15:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU15:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU15:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU15:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU15:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU15:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU15:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU15:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU15:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU15:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU15:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU15:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU15:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU15:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU15:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU15:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU15:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU15:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU15:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU15:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU15:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU15:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU15:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU15:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU15:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU15:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU15:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU15:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU15:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU15:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU15:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU15:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU15:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU15:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU15:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU15:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU15:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU15:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU15:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU15:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU15:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU15:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU15:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU15:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU15:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU15:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU15:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU15:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU15:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU15:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU15:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU15:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU15:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU15:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU15:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU15:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU15:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU15:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU15:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU15:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU15:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU15:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU15:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU15:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU15:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU15:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU15:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU15:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU15:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU15:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU15:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU15:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU15:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU15:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU15:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU15:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU15:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU15:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU15:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU15:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU15:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU15:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU15:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU15:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU15:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU15:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU15:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU15:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU15:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU15:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU15:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU15:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU15:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU15:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU15:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU15:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU15:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU15:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU15:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU15:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU15:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU15:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU15:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU15:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU15:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU15:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU15:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU15:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU15:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU15:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU15:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU15:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU15:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU15:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU15:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU15:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU15:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU15:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU15:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU15:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU15:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU15:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU15:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU15:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU15:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU15:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU15:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU15:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU15:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU15:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU15:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU15:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU15:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU15:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU15:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU15:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU15:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU16:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar15")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU16:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU16:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc15,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU16:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg15,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU16:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU16:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU16:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU16:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU16:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU16:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr15,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU16:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU16:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU16:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU16:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU16:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU16:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU16:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr15,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU16:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU16:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU16:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU16:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU16:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU16:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU16:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr15,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU16:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU16:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU16:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU16:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU16:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU16:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU16:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr15,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU16:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU16:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU16:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU16:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU16:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar15")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU16:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar15")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU16:ATTY")  
}   

record(longin, "HU1:CBPM:HU16:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar15")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU16:ATTREF")  
}   

record(longin, "HU1:CBPM:HU16:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar15")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU16:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU16:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar15")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU16:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar15")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU16:PS_STA")
}

record(bi, "HU1:CBPM:HU16:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar15")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU16:LO_LTCH")
}

record(bi, "HU1:CBPM:HU16:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar15")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU16:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr15,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU16:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar15")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU16:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr15,rcvrSysReg(8,14,1),reg_io15")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU16:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr15,rcvrSysReg(6,8,1),reg_io15")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU16:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr15,rcvrSysReg(6,2,1),reg_io15")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU16:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar15")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar15")   
	field(FLNK, "HU1:CBPM:HU16:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU16:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar15")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU16:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU16:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU16:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU16:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU16:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU16:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU16:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU16:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU16:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU16:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU16:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU16:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU16:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU16:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU16:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU16:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU16:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr15,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU16:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar15")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU16:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU16:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar15")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU16:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU16:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar15")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU16:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU16:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar15")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU16:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU16:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar15")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU16:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU16:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar15")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU16:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU16:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar15")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU16:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU16:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar15")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU16:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU16:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar15")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU16:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar15")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU16:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU16:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar15")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU16:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU16:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar15")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU16:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU16:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar15")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU16:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU16:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar15")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU16:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU16:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar15")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU16:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU16:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar15")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU16:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU16:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar15")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU16:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU16:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll15,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU16:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU16:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU16:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU16:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU16:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU16:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU16:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU16:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU16:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU16:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU16:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU16:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU16:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU16:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU16:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU16:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU16:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU16:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU16:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU16:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU16:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU16:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU16:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU16:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU16:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU16:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU16:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU16:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU16:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU16:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU16:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU16:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU16:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU16:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU16:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU16:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU16:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU16:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU16:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU16:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU16:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU16:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU16:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU16:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU16:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU16:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU16:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU16:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU16:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU16:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU16:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU16:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU16:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU16:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU16:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU16:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU16:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU16:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU16:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU16:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU16:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU16:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU16:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU16:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU16:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU16:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU16:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU16:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU16:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU16:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU16:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU16:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU16:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU16:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU16:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU16:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU16:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU16:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU16:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU16:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU16:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU16:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU16:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU16:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU16:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU16:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU16:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU16:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU16:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU16:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU16:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU16:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU16:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_CHIP_PIN initializes HU1:CBPM:HU16:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_CHIP_SPI initializes HU1:CBPM:HU16:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_RST_CLKS initializes HU1:CBPM:HU16:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_RST_BIAS initializes HU1:CBPM:HU16:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_RST_PFD initializes HU1:CBPM:HU16:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_RST_CP initializes HU1:CBPM:HU16:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_RST_REF initializes HU1:CBPM:HU16:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_RST_VCO initializes HU1:CBPM:HU16:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_RST_IO initializes HU1:CBPM:HU16:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_FRAC_RST initializes HU1:CBPM:HU16:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_FRACBUFF_RST initializes HU1:CBPM:HU16:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_FRACBYP initializes HU1:CBPM:HU16:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_AUTOSEED initializes HU1:CBPM:HU16:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_FSK initializes HU1:CBPM:HU16:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_REFCLK initializes HU1:CBPM:HU16:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_INVCLK initializes HU1:CBPM:HU16:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_ILKD initializes HU1:CBPM:HU16:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_ASYMW initializes HU1:CBPM:HU16:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_ASYMWUP initializes HU1:CBPM:HU16:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_ROSC initializes HU1:CBPM:HU16:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_ROSCTEST initializes HU1:CBPM:HU16:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_CSP initializes HU1:CBPM:HU16:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_BIAS_EN initializes HU1:CBPM:HU16:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_CP_EN initializes HU1:CBPM:HU16:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_PFD_EN initializes HU1:CBPM:HU16:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_REF_EN initializes HU1:CBPM:HU16:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_VCO_EN initializes HU1:CBPM:HU16:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_GPIO_EN initializes HU1:CBPM:HU16:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_LD_EN initializes HU1:CBPM:HU16:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_CLKDIG_EN initializes HU1:CBPM:HU16:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_DIV_EN initializes HU1:CBPM:HU16:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_DCYC_EN initializes HU1:CBPM:HU16:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_REFDIG_EN initializes HU1:CBPM:HU16:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_RDIVDIG_EN initializes HU1:CBPM:HU16:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_VCOSPI_EN initializes HU1:CBPM:HU16:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_PHASSEL initializes HU1:CBPM:HU16:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_PFDUP_EN initializes HU1:CBPM:HU16:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_PFDDN_EN initializes HU1:CBPM:HU16:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_PFDLD_EN initializes HU1:CBPM:HU16:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_PFDUP initializes HU1:CBPM:HU16:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_PFDDN initializes HU1:CBPM:HU16:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU16:PLL_PFDMUTE initializes HU1:CBPM:HU16:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU16:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU16:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU16:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU16:PLL_CSPCORR initializes HU1:CBPM:HU16:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU16:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU16:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU16:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU16:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU16:PLL_LKDW initializes HU1:CBPM:HU16:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU16:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU16:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU16:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU16:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU16:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU16:PLL_PFDDLY initializes HU1:CBPM:HU16:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU16:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU16:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU16:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU16:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU16:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU16:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU16:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU16:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU16:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU16:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU16:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU16:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU16:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU16:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU16:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU16:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU16:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU16:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU16:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU16:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU16:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU16:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU16:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU16:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU16:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU16:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU16:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU16:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU16:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU16:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU16:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU16:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU16:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU16:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU16:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU16:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU16:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU16:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU16:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU16:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU16:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU16:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU16:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU16:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU16:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU16:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU16:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU16:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU16:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU16:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU16:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU16:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU16:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU16:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU16:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU16:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU16:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU16:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU16:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU16:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU16:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU16:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU16:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU16:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU16:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU16:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU16:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU16:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU16:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU16:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU16:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU16:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU16:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU16:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU16:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU16:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU16:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU16:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU16:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU16:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU16:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU16:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU16:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU16:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU16:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU16:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU16:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU16:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU16:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU16:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU16:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU16:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU16:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU16:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU16:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU16:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU16:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU16:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU16:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU16:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU16:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU16:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU16:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU16:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU16:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU16:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU16:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU16:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU16:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU16:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU16:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU16:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU16:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU16:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU16:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU16:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU16:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU16:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU16:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU16:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU16:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU16:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU16:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU16:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU16:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU16:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU16:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU16:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU16:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU16:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU16:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU16:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU16:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU16:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU16:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU16:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU16:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU16:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU16:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU16:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU16:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU16:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU16:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU16:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU16:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU16:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU16:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU16:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU16:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU17:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar16")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU17:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU17:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc16,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU17:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg16,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU17:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU17:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU17:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU17:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU17:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU17:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr16,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU17:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU17:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU17:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU17:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU17:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU17:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU17:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr16,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU17:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU17:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU17:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU17:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU17:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU17:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU17:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr16,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU17:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU17:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU17:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU17:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU17:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU17:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU17:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr16,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU17:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU17:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU17:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU17:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU17:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar16")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU17:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar16")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU17:ATTY")  
}   

record(longin, "HU1:CBPM:HU17:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar16")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU17:ATTREF")  
}   

record(longin, "HU1:CBPM:HU17:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar16")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU17:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU17:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar16")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU17:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar16")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU17:PS_STA")
}

record(bi, "HU1:CBPM:HU17:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar16")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU17:LO_LTCH")
}

record(bi, "HU1:CBPM:HU17:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar16")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU17:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr16,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU17:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar16")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU17:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr16,rcvrSysReg(8,14,1),reg_io16")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU17:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr16,rcvrSysReg(6,8,1),reg_io16")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU17:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr16,rcvrSysReg(6,2,1),reg_io16")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU17:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar16")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar16")   
	field(FLNK, "HU1:CBPM:HU17:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU17:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar16")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU17:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU17:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU17:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU17:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU17:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU17:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU17:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU17:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU17:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU17:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU17:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU17:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU17:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU17:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU17:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU17:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU17:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr16,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU17:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar16")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU17:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU17:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar16")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU17:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU17:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar16")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU17:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU17:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar16")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU17:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU17:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar16")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU17:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU17:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar16")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU17:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU17:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar16")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU17:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU17:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar16")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU17:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU17:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar16")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU17:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar16")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU17:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU17:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar16")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU17:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU17:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar16")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU17:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU17:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar16")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU17:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU17:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar16")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU17:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU17:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar16")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU17:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU17:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar16")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU17:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU17:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar16")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU17:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU17:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll16,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU17:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU17:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU17:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU17:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU17:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU17:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU17:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU17:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU17:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU17:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU17:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU17:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU17:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU17:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU17:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU17:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU17:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU17:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU17:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU17:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU17:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU17:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU17:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU17:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU17:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU17:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU17:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU17:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU17:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU17:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU17:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU17:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU17:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU17:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU17:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU17:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU17:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU17:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU17:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU17:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU17:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU17:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU17:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU17:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU17:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU17:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU17:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU17:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU17:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU17:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU17:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU17:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU17:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU17:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU17:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU17:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU17:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU17:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU17:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU17:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU17:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU17:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU17:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU17:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU17:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU17:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU17:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU17:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU17:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU17:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU17:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU17:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU17:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU17:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU17:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU17:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU17:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU17:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU17:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU17:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU17:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU17:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU17:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU17:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU17:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU17:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU17:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU17:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU17:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU17:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU17:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU17:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU17:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_CHIP_PIN initializes HU1:CBPM:HU17:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_CHIP_SPI initializes HU1:CBPM:HU17:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_RST_CLKS initializes HU1:CBPM:HU17:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_RST_BIAS initializes HU1:CBPM:HU17:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_RST_PFD initializes HU1:CBPM:HU17:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_RST_CP initializes HU1:CBPM:HU17:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_RST_REF initializes HU1:CBPM:HU17:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_RST_VCO initializes HU1:CBPM:HU17:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_RST_IO initializes HU1:CBPM:HU17:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_FRAC_RST initializes HU1:CBPM:HU17:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_FRACBUFF_RST initializes HU1:CBPM:HU17:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_FRACBYP initializes HU1:CBPM:HU17:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_AUTOSEED initializes HU1:CBPM:HU17:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_FSK initializes HU1:CBPM:HU17:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_REFCLK initializes HU1:CBPM:HU17:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_INVCLK initializes HU1:CBPM:HU17:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_ILKD initializes HU1:CBPM:HU17:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_ASYMW initializes HU1:CBPM:HU17:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_ASYMWUP initializes HU1:CBPM:HU17:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_ROSC initializes HU1:CBPM:HU17:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_ROSCTEST initializes HU1:CBPM:HU17:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_CSP initializes HU1:CBPM:HU17:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_BIAS_EN initializes HU1:CBPM:HU17:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_CP_EN initializes HU1:CBPM:HU17:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_PFD_EN initializes HU1:CBPM:HU17:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_REF_EN initializes HU1:CBPM:HU17:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_VCO_EN initializes HU1:CBPM:HU17:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_GPIO_EN initializes HU1:CBPM:HU17:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_LD_EN initializes HU1:CBPM:HU17:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_CLKDIG_EN initializes HU1:CBPM:HU17:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_DIV_EN initializes HU1:CBPM:HU17:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_DCYC_EN initializes HU1:CBPM:HU17:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_REFDIG_EN initializes HU1:CBPM:HU17:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_RDIVDIG_EN initializes HU1:CBPM:HU17:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_VCOSPI_EN initializes HU1:CBPM:HU17:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_PHASSEL initializes HU1:CBPM:HU17:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_PFDUP_EN initializes HU1:CBPM:HU17:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_PFDDN_EN initializes HU1:CBPM:HU17:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_PFDLD_EN initializes HU1:CBPM:HU17:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_PFDUP initializes HU1:CBPM:HU17:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_PFDDN initializes HU1:CBPM:HU17:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU17:PLL_PFDMUTE initializes HU1:CBPM:HU17:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU17:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU17:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU17:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU17:PLL_CSPCORR initializes HU1:CBPM:HU17:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU17:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU17:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU17:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU17:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU17:PLL_LKDW initializes HU1:CBPM:HU17:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU17:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU17:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU17:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU17:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU17:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU17:PLL_PFDDLY initializes HU1:CBPM:HU17:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU17:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU17:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU17:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU17:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU17:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU17:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU17:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU17:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU17:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU17:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU17:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU17:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU17:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU17:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU17:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU17:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU17:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU17:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU17:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU17:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU17:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU17:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU17:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU17:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU17:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU17:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU17:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU17:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU17:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU17:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU17:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU17:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU17:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU17:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU17:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU17:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU17:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU17:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU17:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU17:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU17:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU17:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU17:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU17:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU17:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU17:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU17:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU17:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU17:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU17:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU17:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU17:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU17:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU17:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU17:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU17:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU17:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU17:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU17:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU17:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU17:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU17:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU17:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU17:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU17:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU17:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU17:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU17:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU17:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU17:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU17:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU17:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU17:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU17:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU17:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU17:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU17:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU17:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU17:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU17:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU17:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU17:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU17:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU17:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU17:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU17:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU17:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU17:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU17:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU17:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU17:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU17:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU17:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU17:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU17:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU17:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU17:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU17:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU17:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU17:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU17:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU17:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU17:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU17:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU17:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU17:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU17:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU17:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU17:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU17:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU17:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU17:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU17:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU17:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU17:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU17:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU17:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU17:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU17:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU17:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU17:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU17:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU17:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU17:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU17:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU17:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU17:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU17:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU17:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU17:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU17:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU17:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU17:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU17:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU17:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU17:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU17:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU17:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU17:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU17:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU17:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU17:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU17:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU17:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU17:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU17:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU17:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU17:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU17:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU18:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar17")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU18:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU18:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc17,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU18:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg17,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU18:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU18:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU18:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU18:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU18:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU18:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr17,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU18:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU18:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU18:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU18:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU18:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU18:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU18:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr17,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU18:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU18:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU18:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU18:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU18:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU18:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU18:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr17,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU18:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU18:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU18:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU18:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU18:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU18:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU18:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr17,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU18:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU18:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU18:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU18:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU18:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar17")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU18:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar17")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU18:ATTY")  
}   

record(longin, "HU1:CBPM:HU18:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar17")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU18:ATTREF")  
}   

record(longin, "HU1:CBPM:HU18:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar17")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU18:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU18:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar17")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU18:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar17")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU18:PS_STA")
}

record(bi, "HU1:CBPM:HU18:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar17")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU18:LO_LTCH")
}

record(bi, "HU1:CBPM:HU18:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar17")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU18:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr17,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU18:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar17")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU18:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr17,rcvrSysReg(8,14,1),reg_io17")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU18:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr17,rcvrSysReg(6,8,1),reg_io17")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU18:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr17,rcvrSysReg(6,2,1),reg_io17")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU18:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar17")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar17")   
	field(FLNK, "HU1:CBPM:HU18:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU18:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar17")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU18:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU18:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU18:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU18:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU18:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU18:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU18:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU18:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU18:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU18:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU18:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU18:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU18:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU18:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU18:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU18:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU18:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr17,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU18:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar17")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU18:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU18:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar17")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU18:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU18:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar17")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU18:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU18:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar17")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU18:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU18:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar17")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU18:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU18:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar17")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU18:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU18:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar17")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU18:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU18:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar17")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU18:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU18:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar17")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU18:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar17")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU18:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU18:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar17")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU18:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU18:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar17")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU18:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU18:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar17")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU18:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU18:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar17")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU18:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU18:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar17")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU18:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU18:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar17")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU18:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU18:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar17")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU18:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU18:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll17,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU18:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU18:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU18:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU18:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU18:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU18:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU18:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU18:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU18:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU18:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU18:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU18:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU18:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU18:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU18:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU18:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU18:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU18:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU18:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU18:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU18:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU18:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU18:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU18:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU18:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU18:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU18:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU18:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU18:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU18:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU18:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU18:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU18:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU18:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU18:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU18:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU18:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU18:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU18:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU18:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU18:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU18:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU18:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU18:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU18:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU18:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU18:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU18:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU18:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU18:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU18:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU18:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU18:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU18:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU18:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU18:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU18:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU18:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU18:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU18:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU18:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU18:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU18:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU18:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU18:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU18:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU18:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU18:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU18:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU18:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU18:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU18:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU18:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU18:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU18:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU18:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU18:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU18:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU18:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU18:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU18:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU18:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU18:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU18:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU18:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU18:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU18:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU18:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU18:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU18:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU18:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU18:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU18:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_CHIP_PIN initializes HU1:CBPM:HU18:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_CHIP_SPI initializes HU1:CBPM:HU18:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_RST_CLKS initializes HU1:CBPM:HU18:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_RST_BIAS initializes HU1:CBPM:HU18:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_RST_PFD initializes HU1:CBPM:HU18:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_RST_CP initializes HU1:CBPM:HU18:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_RST_REF initializes HU1:CBPM:HU18:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_RST_VCO initializes HU1:CBPM:HU18:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_RST_IO initializes HU1:CBPM:HU18:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_FRAC_RST initializes HU1:CBPM:HU18:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_FRACBUFF_RST initializes HU1:CBPM:HU18:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_FRACBYP initializes HU1:CBPM:HU18:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_AUTOSEED initializes HU1:CBPM:HU18:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_FSK initializes HU1:CBPM:HU18:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_REFCLK initializes HU1:CBPM:HU18:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_INVCLK initializes HU1:CBPM:HU18:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_ILKD initializes HU1:CBPM:HU18:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_ASYMW initializes HU1:CBPM:HU18:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_ASYMWUP initializes HU1:CBPM:HU18:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_ROSC initializes HU1:CBPM:HU18:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_ROSCTEST initializes HU1:CBPM:HU18:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_CSP initializes HU1:CBPM:HU18:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_BIAS_EN initializes HU1:CBPM:HU18:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_CP_EN initializes HU1:CBPM:HU18:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_PFD_EN initializes HU1:CBPM:HU18:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_REF_EN initializes HU1:CBPM:HU18:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_VCO_EN initializes HU1:CBPM:HU18:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_GPIO_EN initializes HU1:CBPM:HU18:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_LD_EN initializes HU1:CBPM:HU18:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_CLKDIG_EN initializes HU1:CBPM:HU18:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_DIV_EN initializes HU1:CBPM:HU18:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_DCYC_EN initializes HU1:CBPM:HU18:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_REFDIG_EN initializes HU1:CBPM:HU18:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_RDIVDIG_EN initializes HU1:CBPM:HU18:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_VCOSPI_EN initializes HU1:CBPM:HU18:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_PHASSEL initializes HU1:CBPM:HU18:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_PFDUP_EN initializes HU1:CBPM:HU18:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_PFDDN_EN initializes HU1:CBPM:HU18:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_PFDLD_EN initializes HU1:CBPM:HU18:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_PFDUP initializes HU1:CBPM:HU18:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_PFDDN initializes HU1:CBPM:HU18:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU18:PLL_PFDMUTE initializes HU1:CBPM:HU18:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU18:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU18:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU18:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU18:PLL_CSPCORR initializes HU1:CBPM:HU18:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU18:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU18:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU18:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU18:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU18:PLL_LKDW initializes HU1:CBPM:HU18:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU18:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU18:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU18:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU18:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU18:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU18:PLL_PFDDLY initializes HU1:CBPM:HU18:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU18:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU18:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU18:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU18:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU18:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU18:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU18:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU18:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU18:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU18:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU18:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU18:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU18:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU18:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU18:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU18:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU18:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU18:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU18:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU18:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU18:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU18:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU18:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU18:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU18:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU18:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU18:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU18:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU18:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU18:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU18:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU18:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU18:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU18:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU18:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU18:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU18:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU18:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU18:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU18:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU18:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU18:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU18:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU18:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU18:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU18:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU18:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU18:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU18:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU18:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU18:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU18:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU18:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU18:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU18:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU18:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU18:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU18:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU18:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU18:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU18:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU18:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU18:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU18:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU18:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU18:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU18:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU18:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU18:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU18:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU18:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU18:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU18:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU18:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU18:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU18:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU18:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU18:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU18:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU18:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU18:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU18:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU18:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU18:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU18:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU18:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU18:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU18:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU18:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU18:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU18:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU18:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU18:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU18:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU18:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU18:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU18:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU18:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU18:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU18:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU18:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU18:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU18:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU18:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU18:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU18:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU18:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU18:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU18:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU18:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU18:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU18:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU18:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU18:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU18:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU18:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU18:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU18:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU18:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU18:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU18:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU18:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU18:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU18:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU18:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU18:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU18:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU18:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU18:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU18:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU18:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU18:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU18:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU18:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU18:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU18:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU18:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU18:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU18:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU18:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU18:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU18:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU18:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU18:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU18:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU18:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU18:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU18:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU18:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU19:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar18")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU19:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU19:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc18,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU19:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg18,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU19:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU19:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU19:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU19:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU19:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU19:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr18,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU19:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU19:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU19:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU19:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU19:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU19:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU19:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr18,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU19:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU19:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU19:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU19:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU19:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU19:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU19:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr18,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU19:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU19:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU19:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU19:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU19:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU19:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU19:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr18,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU19:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU19:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU19:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU19:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU19:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar18")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU19:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar18")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU19:ATTY")  
}   

record(longin, "HU1:CBPM:HU19:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar18")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU19:ATTREF")  
}   

record(longin, "HU1:CBPM:HU19:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar18")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU19:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU19:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar18")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU19:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar18")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU19:PS_STA")
}

record(bi, "HU1:CBPM:HU19:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar18")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU19:LO_LTCH")
}

record(bi, "HU1:CBPM:HU19:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar18")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU19:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr18,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU19:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar18")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU19:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr18,rcvrSysReg(8,14,1),reg_io18")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU19:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr18,rcvrSysReg(6,8,1),reg_io18")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU19:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr18,rcvrSysReg(6,2,1),reg_io18")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU19:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar18")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar18")   
	field(FLNK, "HU1:CBPM:HU19:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU19:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar18")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU19:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU19:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU19:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU19:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU19:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU19:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU19:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU19:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU19:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU19:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU19:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU19:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU19:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU19:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU19:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU19:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU19:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr18,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU19:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar18")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU19:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU19:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar18")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU19:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU19:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar18")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU19:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU19:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar18")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU19:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU19:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar18")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU19:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU19:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar18")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU19:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU19:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar18")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU19:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU19:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar18")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU19:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU19:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar18")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU19:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar18")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU19:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU19:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar18")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU19:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU19:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar18")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU19:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU19:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar18")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU19:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU19:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar18")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU19:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU19:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar18")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU19:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU19:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar18")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU19:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU19:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar18")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU19:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU19:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll18,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU19:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU19:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU19:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU19:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU19:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU19:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU19:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU19:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU19:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU19:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU19:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU19:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU19:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU19:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU19:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU19:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU19:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU19:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU19:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU19:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU19:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU19:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU19:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU19:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU19:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU19:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU19:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU19:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU19:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU19:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU19:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU19:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU19:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU19:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU19:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU19:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU19:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU19:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU19:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU19:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU19:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU19:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU19:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU19:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU19:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU19:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU19:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU19:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU19:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU19:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU19:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU19:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU19:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU19:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU19:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU19:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU19:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU19:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU19:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU19:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU19:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU19:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU19:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU19:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU19:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU19:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU19:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU19:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU19:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU19:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU19:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU19:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU19:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU19:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU19:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU19:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU19:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU19:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU19:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU19:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU19:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU19:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU19:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU19:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU19:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU19:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU19:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU19:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU19:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU19:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU19:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU19:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU19:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_CHIP_PIN initializes HU1:CBPM:HU19:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_CHIP_SPI initializes HU1:CBPM:HU19:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_RST_CLKS initializes HU1:CBPM:HU19:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_RST_BIAS initializes HU1:CBPM:HU19:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_RST_PFD initializes HU1:CBPM:HU19:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_RST_CP initializes HU1:CBPM:HU19:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_RST_REF initializes HU1:CBPM:HU19:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_RST_VCO initializes HU1:CBPM:HU19:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_RST_IO initializes HU1:CBPM:HU19:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_FRAC_RST initializes HU1:CBPM:HU19:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_FRACBUFF_RST initializes HU1:CBPM:HU19:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_FRACBYP initializes HU1:CBPM:HU19:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_AUTOSEED initializes HU1:CBPM:HU19:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_FSK initializes HU1:CBPM:HU19:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_REFCLK initializes HU1:CBPM:HU19:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_INVCLK initializes HU1:CBPM:HU19:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_ILKD initializes HU1:CBPM:HU19:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_ASYMW initializes HU1:CBPM:HU19:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_ASYMWUP initializes HU1:CBPM:HU19:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_ROSC initializes HU1:CBPM:HU19:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_ROSCTEST initializes HU1:CBPM:HU19:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_CSP initializes HU1:CBPM:HU19:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_BIAS_EN initializes HU1:CBPM:HU19:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_CP_EN initializes HU1:CBPM:HU19:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_PFD_EN initializes HU1:CBPM:HU19:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_REF_EN initializes HU1:CBPM:HU19:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_VCO_EN initializes HU1:CBPM:HU19:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_GPIO_EN initializes HU1:CBPM:HU19:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_LD_EN initializes HU1:CBPM:HU19:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_CLKDIG_EN initializes HU1:CBPM:HU19:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_DIV_EN initializes HU1:CBPM:HU19:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_DCYC_EN initializes HU1:CBPM:HU19:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_REFDIG_EN initializes HU1:CBPM:HU19:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_RDIVDIG_EN initializes HU1:CBPM:HU19:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_VCOSPI_EN initializes HU1:CBPM:HU19:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_PHASSEL initializes HU1:CBPM:HU19:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_PFDUP_EN initializes HU1:CBPM:HU19:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_PFDDN_EN initializes HU1:CBPM:HU19:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_PFDLD_EN initializes HU1:CBPM:HU19:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_PFDUP initializes HU1:CBPM:HU19:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_PFDDN initializes HU1:CBPM:HU19:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU19:PLL_PFDMUTE initializes HU1:CBPM:HU19:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU19:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU19:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU19:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU19:PLL_CSPCORR initializes HU1:CBPM:HU19:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU19:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU19:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU19:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU19:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU19:PLL_LKDW initializes HU1:CBPM:HU19:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU19:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU19:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU19:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU19:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU19:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU19:PLL_PFDDLY initializes HU1:CBPM:HU19:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU19:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU19:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU19:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU19:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU19:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU19:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU19:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU19:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU19:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU19:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU19:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU19:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU19:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU19:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU19:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU19:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU19:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU19:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU19:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU19:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU19:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU19:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU19:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU19:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU19:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU19:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU19:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU19:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU19:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU19:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU19:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU19:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU19:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU19:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU19:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU19:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU19:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU19:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU19:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU19:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU19:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU19:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU19:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU19:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU19:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU19:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU19:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU19:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU19:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU19:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU19:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU19:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU19:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU19:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU19:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU19:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU19:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU19:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU19:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU19:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU19:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU19:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU19:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU19:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU19:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU19:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU19:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU19:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU19:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU19:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU19:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU19:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU19:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU19:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU19:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU19:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU19:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU19:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU19:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU19:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU19:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU19:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU19:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU19:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU19:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU19:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU19:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU19:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU19:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU19:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU19:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU19:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU19:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU19:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU19:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU19:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU19:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU19:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU19:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU19:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU19:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU19:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU19:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU19:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU19:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU19:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU19:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU19:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU19:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU19:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU19:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU19:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU19:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU19:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU19:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU19:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU19:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU19:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU19:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU19:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU19:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU19:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU19:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU19:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU19:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU19:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU19:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU19:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU19:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU19:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU19:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU19:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU19:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU19:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU19:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU19:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU19:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU19:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU19:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU19:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU19:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU19:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU19:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU19:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU19:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU19:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU19:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU19:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU19:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU20:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar19")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU20:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU20:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc19,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU20:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg19,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU20:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU20:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU20:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU20:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU20:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU20:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr19,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU20:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU20:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU20:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU20:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU20:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU20:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU20:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr19,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU20:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU20:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU20:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU20:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU20:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU20:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU20:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr19,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU20:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU20:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU20:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU20:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU20:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU20:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU20:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr19,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU20:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU20:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU20:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU20:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU20:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar19")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU20:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar19")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU20:ATTY")  
}   

record(longin, "HU1:CBPM:HU20:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar19")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU20:ATTREF")  
}   

record(longin, "HU1:CBPM:HU20:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar19")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU20:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU20:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar19")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU20:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar19")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU20:PS_STA")
}

record(bi, "HU1:CBPM:HU20:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar19")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU20:LO_LTCH")
}

record(bi, "HU1:CBPM:HU20:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar19")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU20:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr19,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU20:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar19")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU20:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr19,rcvrSysReg(8,14,1),reg_io19")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU20:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr19,rcvrSysReg(6,8,1),reg_io19")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU20:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr19,rcvrSysReg(6,2,1),reg_io19")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU20:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar19")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar19")   
	field(FLNK, "HU1:CBPM:HU20:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU20:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar19")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU20:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU20:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU20:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU20:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU20:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU20:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU20:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU20:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU20:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU20:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU20:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU20:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU20:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU20:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU20:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU20:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU20:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr19,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU20:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar19")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU20:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU20:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar19")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU20:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU20:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar19")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU20:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU20:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar19")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU20:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU20:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar19")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU20:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU20:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar19")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU20:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU20:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar19")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU20:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU20:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar19")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU20:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU20:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar19")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU20:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar19")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU20:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU20:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar19")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU20:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU20:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar19")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU20:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU20:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar19")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU20:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU20:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar19")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU20:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU20:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar19")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU20:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU20:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar19")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU20:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU20:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar19")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU20:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU20:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll19,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU20:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU20:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU20:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU20:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU20:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU20:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU20:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU20:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU20:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU20:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU20:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU20:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU20:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU20:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU20:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU20:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU20:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU20:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU20:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU20:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU20:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU20:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU20:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU20:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU20:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU20:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU20:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU20:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU20:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU20:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU20:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU20:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU20:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU20:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU20:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU20:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU20:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU20:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU20:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU20:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU20:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU20:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU20:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU20:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU20:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU20:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU20:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU20:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU20:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU20:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU20:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU20:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU20:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU20:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU20:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU20:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU20:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU20:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU20:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU20:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU20:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU20:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU20:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU20:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU20:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU20:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU20:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU20:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU20:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU20:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU20:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU20:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU20:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU20:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU20:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU20:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU20:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU20:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU20:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU20:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU20:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU20:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU20:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU20:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU20:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU20:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU20:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU20:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU20:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU20:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU20:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU20:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU20:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_CHIP_PIN initializes HU1:CBPM:HU20:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_CHIP_SPI initializes HU1:CBPM:HU20:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_RST_CLKS initializes HU1:CBPM:HU20:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_RST_BIAS initializes HU1:CBPM:HU20:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_RST_PFD initializes HU1:CBPM:HU20:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_RST_CP initializes HU1:CBPM:HU20:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_RST_REF initializes HU1:CBPM:HU20:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_RST_VCO initializes HU1:CBPM:HU20:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_RST_IO initializes HU1:CBPM:HU20:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_FRAC_RST initializes HU1:CBPM:HU20:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_FRACBUFF_RST initializes HU1:CBPM:HU20:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_FRACBYP initializes HU1:CBPM:HU20:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_AUTOSEED initializes HU1:CBPM:HU20:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_FSK initializes HU1:CBPM:HU20:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_REFCLK initializes HU1:CBPM:HU20:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_INVCLK initializes HU1:CBPM:HU20:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_ILKD initializes HU1:CBPM:HU20:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_ASYMW initializes HU1:CBPM:HU20:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_ASYMWUP initializes HU1:CBPM:HU20:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_ROSC initializes HU1:CBPM:HU20:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_ROSCTEST initializes HU1:CBPM:HU20:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_CSP initializes HU1:CBPM:HU20:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_BIAS_EN initializes HU1:CBPM:HU20:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_CP_EN initializes HU1:CBPM:HU20:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_PFD_EN initializes HU1:CBPM:HU20:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_REF_EN initializes HU1:CBPM:HU20:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_VCO_EN initializes HU1:CBPM:HU20:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_GPIO_EN initializes HU1:CBPM:HU20:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_LD_EN initializes HU1:CBPM:HU20:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_CLKDIG_EN initializes HU1:CBPM:HU20:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_DIV_EN initializes HU1:CBPM:HU20:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_DCYC_EN initializes HU1:CBPM:HU20:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_REFDIG_EN initializes HU1:CBPM:HU20:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_RDIVDIG_EN initializes HU1:CBPM:HU20:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_VCOSPI_EN initializes HU1:CBPM:HU20:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_PHASSEL initializes HU1:CBPM:HU20:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_PFDUP_EN initializes HU1:CBPM:HU20:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_PFDDN_EN initializes HU1:CBPM:HU20:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_PFDLD_EN initializes HU1:CBPM:HU20:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_PFDUP initializes HU1:CBPM:HU20:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_PFDDN initializes HU1:CBPM:HU20:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU20:PLL_PFDMUTE initializes HU1:CBPM:HU20:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU20:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU20:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU20:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU20:PLL_CSPCORR initializes HU1:CBPM:HU20:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU20:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU20:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU20:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU20:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU20:PLL_LKDW initializes HU1:CBPM:HU20:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU20:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU20:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU20:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU20:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU20:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU20:PLL_PFDDLY initializes HU1:CBPM:HU20:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU20:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU20:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU20:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU20:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU20:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU20:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU20:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU20:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU20:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU20:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU20:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU20:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU20:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU20:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU20:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU20:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU20:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU20:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU20:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU20:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU20:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU20:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU20:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU20:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU20:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU20:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU20:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU20:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU20:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU20:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU20:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU20:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU20:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU20:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU20:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU20:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU20:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU20:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU20:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU20:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU20:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU20:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU20:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU20:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU20:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU20:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU20:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU20:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU20:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU20:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU20:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU20:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU20:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU20:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU20:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU20:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU20:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU20:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU20:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU20:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU20:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU20:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU20:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU20:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU20:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU20:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU20:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU20:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU20:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU20:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU20:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU20:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU20:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU20:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU20:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU20:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU20:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU20:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU20:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU20:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU20:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU20:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU20:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU20:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU20:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU20:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU20:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU20:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU20:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU20:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU20:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU20:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU20:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU20:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU20:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU20:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU20:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU20:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU20:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU20:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU20:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU20:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU20:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU20:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU20:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU20:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU20:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU20:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU20:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU20:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU20:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU20:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU20:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU20:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU20:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU20:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU20:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU20:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU20:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU20:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU20:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU20:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU20:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU20:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU20:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU20:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU20:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU20:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU20:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU20:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU20:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU20:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU20:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU20:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU20:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU20:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU20:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU20:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU20:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU20:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU20:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU20:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU20:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU20:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU20:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU20:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU20:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU20:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU20:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU21:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar20")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU21:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU21:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc20,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU21:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg20,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU21:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU21:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU21:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU21:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU21:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU21:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr20,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU21:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU21:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU21:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU21:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU21:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU21:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU21:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr20,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU21:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU21:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU21:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU21:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU21:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU21:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU21:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr20,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU21:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU21:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU21:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU21:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU21:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU21:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU21:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr20,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU21:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU21:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU21:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU21:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU21:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar20")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU21:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar20")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU21:ATTY")  
}   

record(longin, "HU1:CBPM:HU21:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar20")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU21:ATTREF")  
}   

record(longin, "HU1:CBPM:HU21:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar20")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU21:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU21:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar20")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU21:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar20")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU21:PS_STA")
}

record(bi, "HU1:CBPM:HU21:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar20")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU21:LO_LTCH")
}

record(bi, "HU1:CBPM:HU21:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar20")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU21:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr20,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU21:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar20")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU21:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr20,rcvrSysReg(8,14,1),reg_io20")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU21:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr20,rcvrSysReg(6,8,1),reg_io20")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU21:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr20,rcvrSysReg(6,2,1),reg_io20")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU21:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar20")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar20")   
	field(FLNK, "HU1:CBPM:HU21:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU21:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar20")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU21:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU21:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU21:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU21:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU21:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU21:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU21:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU21:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU21:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU21:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU21:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU21:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU21:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU21:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU21:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU21:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU21:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr20,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU21:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar20")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU21:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU21:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar20")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU21:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU21:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar20")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU21:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU21:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar20")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU21:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU21:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar20")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU21:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU21:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar20")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU21:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU21:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar20")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU21:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU21:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar20")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU21:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU21:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar20")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU21:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar20")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU21:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU21:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar20")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU21:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU21:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar20")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU21:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU21:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar20")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU21:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU21:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar20")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU21:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU21:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar20")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU21:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU21:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar20")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU21:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU21:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar20")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU21:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU21:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll20,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU21:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU21:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU21:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU21:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU21:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU21:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU21:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU21:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU21:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU21:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU21:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU21:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU21:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU21:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU21:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU21:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU21:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU21:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU21:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU21:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU21:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU21:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU21:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU21:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU21:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU21:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU21:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU21:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU21:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU21:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU21:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU21:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU21:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU21:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU21:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU21:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU21:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU21:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU21:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU21:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU21:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU21:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU21:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU21:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU21:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU21:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU21:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU21:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU21:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU21:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU21:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU21:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU21:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU21:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU21:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU21:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU21:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU21:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU21:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU21:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU21:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU21:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU21:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU21:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU21:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU21:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU21:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU21:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU21:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU21:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU21:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU21:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU21:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU21:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU21:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU21:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU21:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU21:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU21:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU21:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU21:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU21:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU21:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU21:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU21:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU21:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU21:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU21:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU21:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU21:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU21:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU21:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU21:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_CHIP_PIN initializes HU1:CBPM:HU21:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_CHIP_SPI initializes HU1:CBPM:HU21:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_RST_CLKS initializes HU1:CBPM:HU21:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_RST_BIAS initializes HU1:CBPM:HU21:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_RST_PFD initializes HU1:CBPM:HU21:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_RST_CP initializes HU1:CBPM:HU21:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_RST_REF initializes HU1:CBPM:HU21:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_RST_VCO initializes HU1:CBPM:HU21:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_RST_IO initializes HU1:CBPM:HU21:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_FRAC_RST initializes HU1:CBPM:HU21:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_FRACBUFF_RST initializes HU1:CBPM:HU21:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_FRACBYP initializes HU1:CBPM:HU21:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_AUTOSEED initializes HU1:CBPM:HU21:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_FSK initializes HU1:CBPM:HU21:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_REFCLK initializes HU1:CBPM:HU21:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_INVCLK initializes HU1:CBPM:HU21:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_ILKD initializes HU1:CBPM:HU21:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_ASYMW initializes HU1:CBPM:HU21:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_ASYMWUP initializes HU1:CBPM:HU21:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_ROSC initializes HU1:CBPM:HU21:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_ROSCTEST initializes HU1:CBPM:HU21:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_CSP initializes HU1:CBPM:HU21:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_BIAS_EN initializes HU1:CBPM:HU21:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_CP_EN initializes HU1:CBPM:HU21:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_PFD_EN initializes HU1:CBPM:HU21:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_REF_EN initializes HU1:CBPM:HU21:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_VCO_EN initializes HU1:CBPM:HU21:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_GPIO_EN initializes HU1:CBPM:HU21:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_LD_EN initializes HU1:CBPM:HU21:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_CLKDIG_EN initializes HU1:CBPM:HU21:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_DIV_EN initializes HU1:CBPM:HU21:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_DCYC_EN initializes HU1:CBPM:HU21:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_REFDIG_EN initializes HU1:CBPM:HU21:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_RDIVDIG_EN initializes HU1:CBPM:HU21:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_VCOSPI_EN initializes HU1:CBPM:HU21:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_PHASSEL initializes HU1:CBPM:HU21:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_PFDUP_EN initializes HU1:CBPM:HU21:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_PFDDN_EN initializes HU1:CBPM:HU21:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_PFDLD_EN initializes HU1:CBPM:HU21:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_PFDUP initializes HU1:CBPM:HU21:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_PFDDN initializes HU1:CBPM:HU21:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU21:PLL_PFDMUTE initializes HU1:CBPM:HU21:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU21:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU21:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU21:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU21:PLL_CSPCORR initializes HU1:CBPM:HU21:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU21:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU21:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU21:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU21:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU21:PLL_LKDW initializes HU1:CBPM:HU21:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU21:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU21:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU21:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU21:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU21:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU21:PLL_PFDDLY initializes HU1:CBPM:HU21:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU21:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU21:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU21:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU21:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU21:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU21:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU21:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU21:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU21:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU21:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU21:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU21:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU21:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU21:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU21:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU21:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU21:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU21:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU21:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU21:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU21:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU21:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU21:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU21:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU21:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU21:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU21:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU21:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU21:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU21:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU21:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU21:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU21:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU21:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU21:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU21:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU21:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU21:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU21:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU21:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU21:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU21:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU21:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU21:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU21:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU21:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU21:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU21:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU21:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU21:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU21:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU21:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU21:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU21:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU21:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU21:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU21:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU21:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU21:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU21:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU21:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU21:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU21:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU21:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU21:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU21:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU21:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU21:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU21:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU21:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU21:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU21:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU21:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU21:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU21:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU21:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU21:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU21:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU21:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU21:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU21:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU21:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU21:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU21:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU21:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU21:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU21:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU21:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU21:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU21:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU21:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU21:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU21:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU21:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU21:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU21:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU21:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU21:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU21:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU21:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU21:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU21:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU21:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU21:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU21:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU21:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU21:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU21:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU21:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU21:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU21:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU21:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU21:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU21:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU21:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU21:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU21:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU21:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU21:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU21:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU21:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU21:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU21:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU21:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU21:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU21:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU21:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU21:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU21:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU21:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU21:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU21:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU21:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU21:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU21:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU21:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU21:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU21:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU21:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU21:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU21:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU21:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU21:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU21:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU21:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU21:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU21:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU21:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU21:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU22:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar21")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU22:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU22:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc21,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU22:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg21,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU22:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU22:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU22:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU22:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU22:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU22:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr21,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU22:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU22:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU22:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU22:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU22:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU22:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU22:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr21,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU22:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU22:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU22:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU22:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU22:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU22:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU22:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr21,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU22:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU22:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU22:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU22:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU22:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU22:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU22:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr21,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU22:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU22:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU22:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU22:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU22:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar21")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU22:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar21")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU22:ATTY")  
}   

record(longin, "HU1:CBPM:HU22:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar21")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU22:ATTREF")  
}   

record(longin, "HU1:CBPM:HU22:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar21")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU22:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU22:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar21")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU22:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar21")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU22:PS_STA")
}

record(bi, "HU1:CBPM:HU22:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar21")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU22:LO_LTCH")
}

record(bi, "HU1:CBPM:HU22:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar21")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU22:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr21,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU22:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar21")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU22:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr21,rcvrSysReg(8,14,1),reg_io21")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU22:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr21,rcvrSysReg(6,8,1),reg_io21")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU22:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr21,rcvrSysReg(6,2,1),reg_io21")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU22:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar21")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar21")   
	field(FLNK, "HU1:CBPM:HU22:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU22:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar21")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU22:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU22:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU22:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU22:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU22:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU22:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU22:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU22:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU22:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU22:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU22:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU22:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU22:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU22:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU22:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU22:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU22:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr21,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU22:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar21")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU22:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU22:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar21")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU22:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU22:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar21")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU22:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU22:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar21")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU22:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU22:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar21")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU22:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU22:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar21")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU22:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU22:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar21")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU22:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU22:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar21")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU22:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU22:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar21")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU22:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar21")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU22:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU22:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar21")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU22:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU22:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar21")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU22:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU22:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar21")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU22:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU22:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar21")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU22:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU22:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar21")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU22:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU22:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar21")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU22:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU22:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar21")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU22:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU22:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll21,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU22:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU22:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU22:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU22:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU22:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU22:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU22:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU22:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU22:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU22:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU22:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU22:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU22:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU22:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU22:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU22:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU22:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU22:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU22:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU22:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU22:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU22:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU22:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU22:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU22:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU22:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU22:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU22:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU22:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU22:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU22:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU22:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU22:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU22:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU22:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU22:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU22:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU22:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU22:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU22:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU22:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU22:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU22:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU22:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU22:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU22:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU22:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU22:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU22:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU22:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU22:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU22:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU22:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU22:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU22:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU22:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU22:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU22:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU22:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU22:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU22:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU22:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU22:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU22:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU22:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU22:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU22:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU22:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU22:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU22:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU22:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU22:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU22:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU22:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU22:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU22:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU22:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU22:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU22:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU22:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU22:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU22:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU22:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU22:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU22:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU22:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU22:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU22:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU22:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU22:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU22:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU22:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU22:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_CHIP_PIN initializes HU1:CBPM:HU22:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_CHIP_SPI initializes HU1:CBPM:HU22:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_RST_CLKS initializes HU1:CBPM:HU22:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_RST_BIAS initializes HU1:CBPM:HU22:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_RST_PFD initializes HU1:CBPM:HU22:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_RST_CP initializes HU1:CBPM:HU22:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_RST_REF initializes HU1:CBPM:HU22:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_RST_VCO initializes HU1:CBPM:HU22:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_RST_IO initializes HU1:CBPM:HU22:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_FRAC_RST initializes HU1:CBPM:HU22:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_FRACBUFF_RST initializes HU1:CBPM:HU22:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_FRACBYP initializes HU1:CBPM:HU22:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_AUTOSEED initializes HU1:CBPM:HU22:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_FSK initializes HU1:CBPM:HU22:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_REFCLK initializes HU1:CBPM:HU22:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_INVCLK initializes HU1:CBPM:HU22:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_ILKD initializes HU1:CBPM:HU22:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_ASYMW initializes HU1:CBPM:HU22:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_ASYMWUP initializes HU1:CBPM:HU22:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_ROSC initializes HU1:CBPM:HU22:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_ROSCTEST initializes HU1:CBPM:HU22:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_CSP initializes HU1:CBPM:HU22:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_BIAS_EN initializes HU1:CBPM:HU22:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_CP_EN initializes HU1:CBPM:HU22:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_PFD_EN initializes HU1:CBPM:HU22:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_REF_EN initializes HU1:CBPM:HU22:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_VCO_EN initializes HU1:CBPM:HU22:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_GPIO_EN initializes HU1:CBPM:HU22:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_LD_EN initializes HU1:CBPM:HU22:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_CLKDIG_EN initializes HU1:CBPM:HU22:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_DIV_EN initializes HU1:CBPM:HU22:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_DCYC_EN initializes HU1:CBPM:HU22:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_REFDIG_EN initializes HU1:CBPM:HU22:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_RDIVDIG_EN initializes HU1:CBPM:HU22:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_VCOSPI_EN initializes HU1:CBPM:HU22:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_PHASSEL initializes HU1:CBPM:HU22:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_PFDUP_EN initializes HU1:CBPM:HU22:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_PFDDN_EN initializes HU1:CBPM:HU22:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_PFDLD_EN initializes HU1:CBPM:HU22:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_PFDUP initializes HU1:CBPM:HU22:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_PFDDN initializes HU1:CBPM:HU22:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU22:PLL_PFDMUTE initializes HU1:CBPM:HU22:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU22:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU22:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU22:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU22:PLL_CSPCORR initializes HU1:CBPM:HU22:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU22:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU22:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU22:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU22:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU22:PLL_LKDW initializes HU1:CBPM:HU22:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU22:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU22:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU22:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU22:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU22:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU22:PLL_PFDDLY initializes HU1:CBPM:HU22:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU22:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU22:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU22:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU22:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU22:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU22:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU22:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU22:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU22:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU22:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU22:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU22:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU22:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU22:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU22:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU22:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU22:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU22:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU22:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU22:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU22:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU22:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU22:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU22:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU22:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU22:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU22:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU22:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU22:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU22:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU22:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU22:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU22:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU22:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU22:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU22:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU22:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU22:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU22:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU22:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU22:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU22:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU22:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU22:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU22:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU22:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU22:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU22:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU22:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU22:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU22:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU22:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU22:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU22:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU22:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU22:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU22:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU22:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU22:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU22:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU22:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU22:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU22:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU22:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU22:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU22:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU22:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU22:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU22:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU22:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU22:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU22:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU22:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU22:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU22:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU22:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU22:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU22:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU22:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU22:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU22:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU22:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU22:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU22:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU22:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU22:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU22:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU22:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU22:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU22:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU22:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU22:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU22:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU22:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU22:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU22:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU22:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU22:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU22:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU22:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU22:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU22:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU22:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU22:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU22:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU22:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU22:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU22:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU22:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU22:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU22:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU22:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU22:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU22:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU22:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU22:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU22:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU22:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU22:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU22:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU22:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU22:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU22:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU22:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU22:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU22:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU22:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU22:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU22:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU22:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU22:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU22:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU22:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU22:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU22:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU22:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU22:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU22:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU22:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU22:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU22:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU22:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU22:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU22:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU22:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU22:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU22:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU22:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU22:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU23:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar22")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU23:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU23:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc22,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU23:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg22,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU23:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU23:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU23:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU23:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU23:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU23:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr22,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU23:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU23:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU23:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU23:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU23:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU23:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU23:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr22,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU23:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU23:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU23:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU23:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU23:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU23:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU23:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr22,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU23:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU23:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU23:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU23:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU23:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU23:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU23:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr22,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU23:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU23:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU23:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU23:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU23:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar22")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU23:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar22")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU23:ATTY")  
}   

record(longin, "HU1:CBPM:HU23:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar22")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU23:ATTREF")  
}   

record(longin, "HU1:CBPM:HU23:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar22")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU23:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU23:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar22")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU23:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar22")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU23:PS_STA")
}

record(bi, "HU1:CBPM:HU23:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar22")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU23:LO_LTCH")
}

record(bi, "HU1:CBPM:HU23:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar22")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU23:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr22,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU23:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar22")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU23:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr22,rcvrSysReg(8,14,1),reg_io22")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU23:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr22,rcvrSysReg(6,8,1),reg_io22")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU23:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr22,rcvrSysReg(6,2,1),reg_io22")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU23:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar22")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar22")   
	field(FLNK, "HU1:CBPM:HU23:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU23:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar22")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU23:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU23:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU23:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU23:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU23:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU23:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU23:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU23:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU23:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU23:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU23:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU23:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU23:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU23:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU23:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU23:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU23:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr22,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU23:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar22")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU23:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU23:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar22")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU23:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU23:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar22")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU23:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU23:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar22")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU23:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU23:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar22")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU23:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU23:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar22")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU23:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU23:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar22")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU23:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU23:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar22")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU23:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU23:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar22")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU23:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar22")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU23:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU23:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar22")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU23:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU23:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar22")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU23:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU23:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar22")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU23:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU23:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar22")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU23:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU23:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar22")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU23:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU23:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar22")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU23:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU23:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar22")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU23:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU23:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll22,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU23:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU23:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU23:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU23:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU23:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU23:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU23:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU23:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU23:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU23:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU23:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU23:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU23:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU23:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU23:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU23:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU23:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU23:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU23:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU23:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU23:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU23:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU23:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU23:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU23:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU23:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU23:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU23:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU23:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU23:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU23:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU23:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU23:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU23:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU23:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU23:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU23:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU23:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU23:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU23:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU23:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU23:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU23:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU23:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU23:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU23:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU23:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU23:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU23:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU23:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU23:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU23:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU23:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU23:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU23:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU23:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU23:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU23:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU23:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU23:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU23:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU23:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU23:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU23:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU23:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU23:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU23:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU23:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU23:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU23:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU23:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU23:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU23:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU23:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU23:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU23:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU23:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU23:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU23:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU23:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU23:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU23:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU23:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU23:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU23:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU23:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU23:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU23:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU23:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU23:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU23:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU23:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU23:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_CHIP_PIN initializes HU1:CBPM:HU23:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_CHIP_SPI initializes HU1:CBPM:HU23:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_RST_CLKS initializes HU1:CBPM:HU23:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_RST_BIAS initializes HU1:CBPM:HU23:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_RST_PFD initializes HU1:CBPM:HU23:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_RST_CP initializes HU1:CBPM:HU23:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_RST_REF initializes HU1:CBPM:HU23:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_RST_VCO initializes HU1:CBPM:HU23:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_RST_IO initializes HU1:CBPM:HU23:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_FRAC_RST initializes HU1:CBPM:HU23:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_FRACBUFF_RST initializes HU1:CBPM:HU23:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_FRACBYP initializes HU1:CBPM:HU23:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_AUTOSEED initializes HU1:CBPM:HU23:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_FSK initializes HU1:CBPM:HU23:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_REFCLK initializes HU1:CBPM:HU23:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_INVCLK initializes HU1:CBPM:HU23:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_ILKD initializes HU1:CBPM:HU23:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_ASYMW initializes HU1:CBPM:HU23:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_ASYMWUP initializes HU1:CBPM:HU23:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_ROSC initializes HU1:CBPM:HU23:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_ROSCTEST initializes HU1:CBPM:HU23:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_CSP initializes HU1:CBPM:HU23:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_BIAS_EN initializes HU1:CBPM:HU23:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_CP_EN initializes HU1:CBPM:HU23:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_PFD_EN initializes HU1:CBPM:HU23:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_REF_EN initializes HU1:CBPM:HU23:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_VCO_EN initializes HU1:CBPM:HU23:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_GPIO_EN initializes HU1:CBPM:HU23:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_LD_EN initializes HU1:CBPM:HU23:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_CLKDIG_EN initializes HU1:CBPM:HU23:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_DIV_EN initializes HU1:CBPM:HU23:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_DCYC_EN initializes HU1:CBPM:HU23:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_REFDIG_EN initializes HU1:CBPM:HU23:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_RDIVDIG_EN initializes HU1:CBPM:HU23:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_VCOSPI_EN initializes HU1:CBPM:HU23:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_PHASSEL initializes HU1:CBPM:HU23:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_PFDUP_EN initializes HU1:CBPM:HU23:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_PFDDN_EN initializes HU1:CBPM:HU23:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_PFDLD_EN initializes HU1:CBPM:HU23:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_PFDUP initializes HU1:CBPM:HU23:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_PFDDN initializes HU1:CBPM:HU23:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU23:PLL_PFDMUTE initializes HU1:CBPM:HU23:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU23:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU23:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU23:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU23:PLL_CSPCORR initializes HU1:CBPM:HU23:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU23:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU23:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU23:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU23:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU23:PLL_LKDW initializes HU1:CBPM:HU23:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU23:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU23:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU23:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU23:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU23:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU23:PLL_PFDDLY initializes HU1:CBPM:HU23:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU23:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU23:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU23:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU23:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU23:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU23:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU23:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU23:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU23:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU23:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU23:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU23:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU23:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU23:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU23:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU23:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU23:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU23:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU23:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU23:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU23:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU23:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU23:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU23:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU23:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU23:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU23:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU23:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU23:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU23:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU23:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU23:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU23:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU23:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU23:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU23:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU23:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU23:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU23:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU23:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU23:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU23:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU23:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU23:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU23:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU23:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU23:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU23:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU23:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU23:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU23:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU23:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU23:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU23:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU23:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU23:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU23:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU23:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU23:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU23:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU23:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU23:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU23:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU23:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU23:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU23:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU23:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU23:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU23:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU23:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU23:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU23:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU23:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU23:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU23:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU23:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU23:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU23:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU23:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU23:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU23:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU23:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU23:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU23:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU23:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU23:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU23:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU23:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU23:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU23:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU23:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU23:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU23:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU23:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU23:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU23:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU23:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU23:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU23:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU23:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU23:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU23:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU23:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU23:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU23:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU23:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU23:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU23:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU23:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU23:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU23:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU23:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU23:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU23:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU23:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU23:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU23:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU23:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU23:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU23:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU23:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU23:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU23:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU23:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU23:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU23:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU23:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU23:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU23:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU23:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU23:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU23:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU23:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU23:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU23:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU23:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU23:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU23:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU23:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU23:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU23:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU23:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU23:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU23:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU23:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU23:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU23:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU23:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU23:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU24:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar23")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU24:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU24:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc23,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU24:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg23,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU24:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU24:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU24:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU24:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU24:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU24:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr23,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU24:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU24:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU24:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU24:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU24:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU24:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU24:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr23,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU24:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU24:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU24:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU24:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU24:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU24:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU24:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr23,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU24:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU24:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU24:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU24:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU24:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU24:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU24:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr23,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU24:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU24:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU24:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU24:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU24:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar23")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU24:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar23")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU24:ATTY")  
}   

record(longin, "HU1:CBPM:HU24:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar23")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU24:ATTREF")  
}   

record(longin, "HU1:CBPM:HU24:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar23")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU24:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU24:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar23")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU24:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar23")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU24:PS_STA")
}

record(bi, "HU1:CBPM:HU24:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar23")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU24:LO_LTCH")
}

record(bi, "HU1:CBPM:HU24:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar23")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU24:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr23,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU24:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar23")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU24:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr23,rcvrSysReg(8,14,1),reg_io23")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU24:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr23,rcvrSysReg(6,8,1),reg_io23")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU24:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr23,rcvrSysReg(6,2,1),reg_io23")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU24:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar23")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar23")   
	field(FLNK, "HU1:CBPM:HU24:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU24:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar23")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU24:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU24:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU24:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU24:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU24:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU24:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU24:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU24:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU24:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU24:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU24:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU24:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU24:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU24:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU24:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU24:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU24:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr23,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU24:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar23")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU24:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU24:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar23")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU24:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU24:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar23")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU24:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU24:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar23")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU24:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU24:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar23")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU24:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU24:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar23")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU24:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU24:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar23")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU24:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU24:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar23")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU24:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU24:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar23")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU24:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar23")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU24:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU24:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar23")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU24:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU24:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar23")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU24:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU24:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar23")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU24:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU24:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar23")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU24:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU24:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar23")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU24:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU24:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar23")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU24:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU24:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar23")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU24:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU24:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll23,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU24:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU24:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU24:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU24:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU24:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU24:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU24:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU24:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU24:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU24:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU24:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU24:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU24:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU24:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU24:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU24:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU24:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU24:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU24:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU24:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU24:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU24:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU24:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU24:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU24:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU24:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU24:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU24:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU24:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU24:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU24:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU24:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU24:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU24:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU24:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU24:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU24:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU24:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU24:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU24:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU24:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU24:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU24:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU24:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU24:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU24:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU24:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU24:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU24:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU24:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU24:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU24:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU24:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU24:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU24:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU24:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU24:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU24:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU24:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU24:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU24:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU24:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU24:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU24:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU24:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU24:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU24:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU24:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU24:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU24:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU24:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU24:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU24:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU24:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU24:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU24:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU24:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU24:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU24:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU24:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU24:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU24:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU24:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU24:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU24:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU24:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU24:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU24:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU24:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU24:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU24:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU24:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU24:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_CHIP_PIN initializes HU1:CBPM:HU24:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_CHIP_SPI initializes HU1:CBPM:HU24:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_RST_CLKS initializes HU1:CBPM:HU24:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_RST_BIAS initializes HU1:CBPM:HU24:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_RST_PFD initializes HU1:CBPM:HU24:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_RST_CP initializes HU1:CBPM:HU24:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_RST_REF initializes HU1:CBPM:HU24:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_RST_VCO initializes HU1:CBPM:HU24:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_RST_IO initializes HU1:CBPM:HU24:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_FRAC_RST initializes HU1:CBPM:HU24:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_FRACBUFF_RST initializes HU1:CBPM:HU24:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_FRACBYP initializes HU1:CBPM:HU24:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_AUTOSEED initializes HU1:CBPM:HU24:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_FSK initializes HU1:CBPM:HU24:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_REFCLK initializes HU1:CBPM:HU24:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_INVCLK initializes HU1:CBPM:HU24:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_ILKD initializes HU1:CBPM:HU24:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_ASYMW initializes HU1:CBPM:HU24:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_ASYMWUP initializes HU1:CBPM:HU24:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_ROSC initializes HU1:CBPM:HU24:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_ROSCTEST initializes HU1:CBPM:HU24:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_CSP initializes HU1:CBPM:HU24:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_BIAS_EN initializes HU1:CBPM:HU24:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_CP_EN initializes HU1:CBPM:HU24:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_PFD_EN initializes HU1:CBPM:HU24:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_REF_EN initializes HU1:CBPM:HU24:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_VCO_EN initializes HU1:CBPM:HU24:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_GPIO_EN initializes HU1:CBPM:HU24:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_LD_EN initializes HU1:CBPM:HU24:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_CLKDIG_EN initializes HU1:CBPM:HU24:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_DIV_EN initializes HU1:CBPM:HU24:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_DCYC_EN initializes HU1:CBPM:HU24:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_REFDIG_EN initializes HU1:CBPM:HU24:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_RDIVDIG_EN initializes HU1:CBPM:HU24:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_VCOSPI_EN initializes HU1:CBPM:HU24:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_PHASSEL initializes HU1:CBPM:HU24:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_PFDUP_EN initializes HU1:CBPM:HU24:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_PFDDN_EN initializes HU1:CBPM:HU24:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_PFDLD_EN initializes HU1:CBPM:HU24:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_PFDUP initializes HU1:CBPM:HU24:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_PFDDN initializes HU1:CBPM:HU24:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU24:PLL_PFDMUTE initializes HU1:CBPM:HU24:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU24:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU24:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU24:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU24:PLL_CSPCORR initializes HU1:CBPM:HU24:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU24:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU24:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU24:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU24:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU24:PLL_LKDW initializes HU1:CBPM:HU24:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU24:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU24:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU24:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU24:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU24:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU24:PLL_PFDDLY initializes HU1:CBPM:HU24:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU24:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU24:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU24:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU24:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU24:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU24:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU24:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU24:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU24:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU24:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU24:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU24:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU24:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU24:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU24:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU24:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU24:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU24:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU24:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU24:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU24:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU24:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU24:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU24:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU24:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU24:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU24:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU24:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU24:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU24:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU24:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU24:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU24:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU24:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU24:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU24:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU24:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU24:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU24:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU24:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU24:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU24:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU24:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU24:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU24:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU24:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU24:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU24:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU24:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU24:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU24:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU24:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU24:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU24:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU24:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU24:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU24:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU24:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU24:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU24:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU24:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU24:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU24:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU24:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU24:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU24:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU24:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU24:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU24:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU24:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU24:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU24:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU24:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU24:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU24:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU24:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU24:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU24:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU24:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU24:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU24:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU24:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU24:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU24:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU24:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU24:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU24:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU24:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU24:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU24:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU24:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU24:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU24:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU24:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU24:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU24:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU24:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU24:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU24:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU24:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU24:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU24:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU24:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU24:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU24:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU24:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU24:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU24:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU24:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU24:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU24:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU24:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU24:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU24:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU24:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU24:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU24:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU24:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU24:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU24:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU24:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU24:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU24:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU24:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU24:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU24:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU24:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU24:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU24:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU24:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU24:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU24:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU24:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU24:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU24:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU24:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU24:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU24:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU24:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU24:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU24:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU24:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU24:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU24:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU24:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU24:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU24:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU24:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU24:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU25:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar24")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU25:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU25:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc24,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU25:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg24,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU25:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU25:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU25:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU25:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU25:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU25:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr24,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU25:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU25:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU25:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU25:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU25:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU25:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU25:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr24,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU25:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU25:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU25:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU25:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU25:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU25:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU25:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr24,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU25:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU25:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU25:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU25:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU25:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU25:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU25:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr24,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU25:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU25:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU25:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU25:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU25:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar24")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU25:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar24")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU25:ATTY")  
}   

record(longin, "HU1:CBPM:HU25:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar24")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU25:ATTREF")  
}   

record(longin, "HU1:CBPM:HU25:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar24")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU25:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU25:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar24")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU25:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar24")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU25:PS_STA")
}

record(bi, "HU1:CBPM:HU25:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar24")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU25:LO_LTCH")
}

record(bi, "HU1:CBPM:HU25:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar24")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU25:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr24,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU25:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar24")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU25:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr24,rcvrSysReg(8,14,1),reg_io24")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU25:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr24,rcvrSysReg(6,8,1),reg_io24")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU25:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr24,rcvrSysReg(6,2,1),reg_io24")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU25:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar24")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar24")   
	field(FLNK, "HU1:CBPM:HU25:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU25:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar24")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU25:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU25:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU25:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU25:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU25:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU25:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU25:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU25:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU25:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU25:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU25:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU25:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU25:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU25:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU25:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU25:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU25:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr24,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU25:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar24")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU25:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU25:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar24")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU25:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU25:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar24")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU25:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU25:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar24")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU25:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU25:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar24")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU25:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU25:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar24")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU25:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU25:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar24")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU25:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU25:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar24")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU25:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU25:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar24")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU25:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar24")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU25:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU25:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar24")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU25:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU25:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar24")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU25:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU25:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar24")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU25:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU25:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar24")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU25:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU25:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar24")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU25:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU25:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar24")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU25:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU25:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar24")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU25:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU25:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll24,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU25:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU25:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU25:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU25:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU25:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU25:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU25:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU25:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU25:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU25:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU25:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU25:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU25:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU25:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU25:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU25:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU25:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU25:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU25:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU25:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU25:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU25:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU25:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU25:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU25:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU25:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU25:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU25:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU25:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU25:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU25:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU25:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU25:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU25:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU25:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU25:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU25:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU25:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU25:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU25:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU25:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU25:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU25:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU25:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU25:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU25:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU25:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU25:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU25:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU25:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU25:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU25:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU25:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU25:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU25:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU25:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU25:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU25:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU25:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU25:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU25:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU25:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU25:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU25:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU25:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU25:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU25:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU25:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU25:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU25:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU25:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU25:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU25:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU25:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU25:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU25:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU25:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU25:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU25:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU25:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU25:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU25:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU25:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU25:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU25:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU25:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU25:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU25:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU25:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU25:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU25:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU25:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU25:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_CHIP_PIN initializes HU1:CBPM:HU25:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_CHIP_SPI initializes HU1:CBPM:HU25:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_RST_CLKS initializes HU1:CBPM:HU25:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_RST_BIAS initializes HU1:CBPM:HU25:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_RST_PFD initializes HU1:CBPM:HU25:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_RST_CP initializes HU1:CBPM:HU25:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_RST_REF initializes HU1:CBPM:HU25:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_RST_VCO initializes HU1:CBPM:HU25:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_RST_IO initializes HU1:CBPM:HU25:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_FRAC_RST initializes HU1:CBPM:HU25:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_FRACBUFF_RST initializes HU1:CBPM:HU25:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_FRACBYP initializes HU1:CBPM:HU25:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_AUTOSEED initializes HU1:CBPM:HU25:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_FSK initializes HU1:CBPM:HU25:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_REFCLK initializes HU1:CBPM:HU25:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_INVCLK initializes HU1:CBPM:HU25:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_ILKD initializes HU1:CBPM:HU25:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_ASYMW initializes HU1:CBPM:HU25:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_ASYMWUP initializes HU1:CBPM:HU25:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_ROSC initializes HU1:CBPM:HU25:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_ROSCTEST initializes HU1:CBPM:HU25:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_CSP initializes HU1:CBPM:HU25:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_BIAS_EN initializes HU1:CBPM:HU25:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_CP_EN initializes HU1:CBPM:HU25:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_PFD_EN initializes HU1:CBPM:HU25:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_REF_EN initializes HU1:CBPM:HU25:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_VCO_EN initializes HU1:CBPM:HU25:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_GPIO_EN initializes HU1:CBPM:HU25:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_LD_EN initializes HU1:CBPM:HU25:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_CLKDIG_EN initializes HU1:CBPM:HU25:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_DIV_EN initializes HU1:CBPM:HU25:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_DCYC_EN initializes HU1:CBPM:HU25:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_REFDIG_EN initializes HU1:CBPM:HU25:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_RDIVDIG_EN initializes HU1:CBPM:HU25:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_VCOSPI_EN initializes HU1:CBPM:HU25:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_PHASSEL initializes HU1:CBPM:HU25:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_PFDUP_EN initializes HU1:CBPM:HU25:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_PFDDN_EN initializes HU1:CBPM:HU25:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_PFDLD_EN initializes HU1:CBPM:HU25:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_PFDUP initializes HU1:CBPM:HU25:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_PFDDN initializes HU1:CBPM:HU25:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU25:PLL_PFDMUTE initializes HU1:CBPM:HU25:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU25:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU25:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU25:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU25:PLL_CSPCORR initializes HU1:CBPM:HU25:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU25:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU25:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU25:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU25:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU25:PLL_LKDW initializes HU1:CBPM:HU25:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU25:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU25:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU25:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU25:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU25:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU25:PLL_PFDDLY initializes HU1:CBPM:HU25:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU25:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU25:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU25:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU25:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU25:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU25:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU25:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU25:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU25:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU25:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU25:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU25:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU25:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU25:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU25:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU25:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU25:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU25:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU25:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU25:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU25:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU25:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU25:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU25:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU25:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU25:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU25:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU25:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU25:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU25:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU25:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU25:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU25:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU25:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU25:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU25:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU25:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU25:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU25:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU25:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU25:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU25:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU25:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU25:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU25:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU25:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU25:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU25:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU25:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU25:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU25:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU25:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU25:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU25:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU25:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU25:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU25:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU25:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU25:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU25:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU25:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU25:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU25:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU25:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU25:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU25:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU25:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU25:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU25:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU25:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU25:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU25:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU25:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU25:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU25:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU25:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU25:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU25:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU25:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU25:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU25:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU25:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU25:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU25:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU25:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU25:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU25:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU25:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU25:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU25:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU25:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU25:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU25:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU25:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU25:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU25:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU25:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU25:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU25:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU25:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU25:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU25:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU25:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU25:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU25:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU25:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU25:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU25:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU25:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU25:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU25:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU25:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU25:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU25:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU25:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU25:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU25:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU25:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU25:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU25:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU25:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU25:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU25:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU25:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU25:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU25:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU25:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU25:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU25:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU25:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU25:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU25:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU25:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU25:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU25:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU25:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU25:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU25:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU25:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU25:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU25:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU25:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU25:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU25:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU25:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU25:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU25:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU25:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU25:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU26:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar25")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU26:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU26:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc25,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU26:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg25,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU26:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU26:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU26:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU26:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU26:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU26:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr25,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU26:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU26:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU26:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU26:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU26:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU26:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU26:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr25,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU26:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU26:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU26:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU26:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU26:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU26:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU26:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr25,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU26:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU26:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU26:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU26:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU26:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU26:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU26:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr25,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU26:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU26:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU26:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU26:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU26:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar25")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU26:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar25")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU26:ATTY")  
}   

record(longin, "HU1:CBPM:HU26:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar25")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU26:ATTREF")  
}   

record(longin, "HU1:CBPM:HU26:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar25")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU26:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU26:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar25")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU26:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar25")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU26:PS_STA")
}

record(bi, "HU1:CBPM:HU26:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar25")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU26:LO_LTCH")
}

record(bi, "HU1:CBPM:HU26:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar25")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU26:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr25,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU26:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar25")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU26:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr25,rcvrSysReg(8,14,1),reg_io25")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU26:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr25,rcvrSysReg(6,8,1),reg_io25")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU26:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr25,rcvrSysReg(6,2,1),reg_io25")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU26:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar25")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar25")   
	field(FLNK, "HU1:CBPM:HU26:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU26:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar25")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU26:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU26:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU26:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU26:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU26:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU26:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU26:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU26:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU26:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU26:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU26:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU26:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU26:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU26:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU26:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU26:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU26:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr25,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU26:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar25")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU26:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU26:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar25")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU26:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU26:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar25")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU26:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU26:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar25")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU26:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU26:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar25")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU26:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU26:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar25")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU26:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU26:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar25")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU26:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU26:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar25")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU26:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU26:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar25")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU26:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar25")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU26:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU26:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar25")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU26:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU26:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar25")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU26:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU26:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar25")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU26:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU26:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar25")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU26:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU26:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar25")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU26:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU26:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar25")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU26:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU26:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar25")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU26:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU26:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll25,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU26:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU26:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU26:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU26:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU26:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU26:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU26:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU26:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU26:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU26:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU26:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU26:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU26:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU26:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU26:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU26:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU26:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU26:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU26:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU26:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU26:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU26:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU26:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU26:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU26:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU26:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU26:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU26:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU26:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU26:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU26:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU26:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU26:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU26:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU26:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU26:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU26:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU26:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU26:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU26:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU26:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU26:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU26:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU26:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU26:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU26:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU26:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU26:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU26:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU26:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU26:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU26:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU26:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU26:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU26:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU26:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU26:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU26:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU26:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU26:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU26:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU26:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU26:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU26:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU26:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU26:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU26:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU26:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU26:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU26:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU26:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU26:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU26:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU26:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU26:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU26:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU26:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU26:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU26:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU26:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU26:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU26:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU26:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU26:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU26:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU26:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU26:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU26:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU26:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU26:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU26:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU26:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU26:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_CHIP_PIN initializes HU1:CBPM:HU26:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_CHIP_SPI initializes HU1:CBPM:HU26:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_RST_CLKS initializes HU1:CBPM:HU26:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_RST_BIAS initializes HU1:CBPM:HU26:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_RST_PFD initializes HU1:CBPM:HU26:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_RST_CP initializes HU1:CBPM:HU26:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_RST_REF initializes HU1:CBPM:HU26:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_RST_VCO initializes HU1:CBPM:HU26:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_RST_IO initializes HU1:CBPM:HU26:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_FRAC_RST initializes HU1:CBPM:HU26:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_FRACBUFF_RST initializes HU1:CBPM:HU26:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_FRACBYP initializes HU1:CBPM:HU26:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_AUTOSEED initializes HU1:CBPM:HU26:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_FSK initializes HU1:CBPM:HU26:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_REFCLK initializes HU1:CBPM:HU26:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_INVCLK initializes HU1:CBPM:HU26:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_ILKD initializes HU1:CBPM:HU26:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_ASYMW initializes HU1:CBPM:HU26:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_ASYMWUP initializes HU1:CBPM:HU26:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_ROSC initializes HU1:CBPM:HU26:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_ROSCTEST initializes HU1:CBPM:HU26:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_CSP initializes HU1:CBPM:HU26:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_BIAS_EN initializes HU1:CBPM:HU26:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_CP_EN initializes HU1:CBPM:HU26:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_PFD_EN initializes HU1:CBPM:HU26:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_REF_EN initializes HU1:CBPM:HU26:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_VCO_EN initializes HU1:CBPM:HU26:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_GPIO_EN initializes HU1:CBPM:HU26:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_LD_EN initializes HU1:CBPM:HU26:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_CLKDIG_EN initializes HU1:CBPM:HU26:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_DIV_EN initializes HU1:CBPM:HU26:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_DCYC_EN initializes HU1:CBPM:HU26:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_REFDIG_EN initializes HU1:CBPM:HU26:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_RDIVDIG_EN initializes HU1:CBPM:HU26:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_VCOSPI_EN initializes HU1:CBPM:HU26:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_PHASSEL initializes HU1:CBPM:HU26:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_PFDUP_EN initializes HU1:CBPM:HU26:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_PFDDN_EN initializes HU1:CBPM:HU26:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_PFDLD_EN initializes HU1:CBPM:HU26:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_PFDUP initializes HU1:CBPM:HU26:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_PFDDN initializes HU1:CBPM:HU26:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU26:PLL_PFDMUTE initializes HU1:CBPM:HU26:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU26:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU26:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU26:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU26:PLL_CSPCORR initializes HU1:CBPM:HU26:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU26:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU26:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU26:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU26:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU26:PLL_LKDW initializes HU1:CBPM:HU26:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU26:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU26:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU26:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU26:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU26:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU26:PLL_PFDDLY initializes HU1:CBPM:HU26:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU26:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU26:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU26:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU26:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU26:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU26:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU26:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU26:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU26:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU26:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU26:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU26:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU26:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU26:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU26:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU26:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU26:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU26:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU26:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU26:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU26:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU26:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU26:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU26:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU26:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU26:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU26:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU26:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU26:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU26:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU26:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU26:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU26:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU26:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU26:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU26:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU26:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU26:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU26:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU26:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU26:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU26:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU26:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU26:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU26:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU26:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU26:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU26:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU26:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU26:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU26:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU26:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU26:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU26:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU26:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU26:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU26:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU26:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU26:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU26:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU26:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU26:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU26:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU26:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU26:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU26:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU26:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU26:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU26:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU26:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU26:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU26:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU26:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU26:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU26:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU26:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU26:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU26:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU26:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU26:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU26:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU26:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU26:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU26:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU26:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU26:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU26:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU26:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU26:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU26:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU26:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU26:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU26:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU26:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU26:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU26:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU26:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU26:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU26:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU26:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU26:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU26:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU26:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU26:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU26:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU26:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU26:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU26:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU26:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU26:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU26:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU26:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU26:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU26:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU26:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU26:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU26:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU26:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU26:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU26:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU26:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU26:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU26:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU26:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU26:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU26:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU26:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU26:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU26:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU26:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU26:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU26:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU26:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU26:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU26:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU26:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU26:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU26:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU26:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU26:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU26:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU26:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU26:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU26:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU26:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU26:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU26:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU26:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU26:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU27:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar26")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU27:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU27:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc26,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU27:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg26,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU27:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU27:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU27:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU27:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU27:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU27:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr26,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU27:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU27:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU27:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU27:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU27:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU27:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU27:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr26,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU27:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU27:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU27:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU27:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU27:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU27:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU27:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr26,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU27:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU27:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU27:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU27:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU27:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU27:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU27:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr26,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU27:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU27:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU27:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU27:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU27:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar26")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU27:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar26")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU27:ATTY")  
}   

record(longin, "HU1:CBPM:HU27:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar26")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU27:ATTREF")  
}   

record(longin, "HU1:CBPM:HU27:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar26")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU27:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU27:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar26")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU27:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar26")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU27:PS_STA")
}

record(bi, "HU1:CBPM:HU27:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar26")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU27:LO_LTCH")
}

record(bi, "HU1:CBPM:HU27:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar26")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU27:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr26,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU27:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar26")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU27:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr26,rcvrSysReg(8,14,1),reg_io26")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU27:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr26,rcvrSysReg(6,8,1),reg_io26")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU27:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr26,rcvrSysReg(6,2,1),reg_io26")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU27:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar26")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar26")   
	field(FLNK, "HU1:CBPM:HU27:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU27:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar26")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU27:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU27:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU27:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU27:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU27:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU27:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU27:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU27:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU27:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU27:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU27:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU27:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU27:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU27:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU27:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU27:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU27:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr26,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU27:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar26")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU27:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU27:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar26")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU27:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU27:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar26")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU27:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU27:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar26")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU27:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU27:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar26")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU27:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU27:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar26")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU27:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU27:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar26")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU27:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU27:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar26")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU27:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU27:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar26")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU27:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar26")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU27:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU27:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar26")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU27:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU27:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar26")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU27:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU27:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar26")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU27:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU27:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar26")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU27:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU27:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar26")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU27:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU27:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar26")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU27:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU27:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar26")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU27:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU27:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll26,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU27:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU27:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU27:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU27:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU27:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU27:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU27:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU27:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU27:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU27:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU27:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU27:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU27:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU27:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU27:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU27:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU27:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU27:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU27:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU27:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU27:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU27:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU27:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU27:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU27:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU27:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU27:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU27:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU27:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU27:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU27:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU27:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU27:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU27:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU27:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU27:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU27:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU27:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU27:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU27:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU27:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU27:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU27:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU27:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU27:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU27:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU27:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU27:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU27:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU27:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU27:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU27:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU27:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU27:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU27:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU27:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU27:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU27:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU27:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU27:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU27:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU27:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU27:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU27:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU27:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU27:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU27:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU27:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU27:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU27:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU27:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU27:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU27:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU27:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU27:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU27:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU27:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU27:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU27:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU27:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU27:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU27:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU27:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU27:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU27:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU27:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU27:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU27:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU27:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU27:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU27:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU27:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU27:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_CHIP_PIN initializes HU1:CBPM:HU27:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_CHIP_SPI initializes HU1:CBPM:HU27:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_RST_CLKS initializes HU1:CBPM:HU27:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_RST_BIAS initializes HU1:CBPM:HU27:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_RST_PFD initializes HU1:CBPM:HU27:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_RST_CP initializes HU1:CBPM:HU27:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_RST_REF initializes HU1:CBPM:HU27:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_RST_VCO initializes HU1:CBPM:HU27:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_RST_IO initializes HU1:CBPM:HU27:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_FRAC_RST initializes HU1:CBPM:HU27:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_FRACBUFF_RST initializes HU1:CBPM:HU27:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_FRACBYP initializes HU1:CBPM:HU27:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_AUTOSEED initializes HU1:CBPM:HU27:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_FSK initializes HU1:CBPM:HU27:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_REFCLK initializes HU1:CBPM:HU27:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_INVCLK initializes HU1:CBPM:HU27:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_ILKD initializes HU1:CBPM:HU27:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_ASYMW initializes HU1:CBPM:HU27:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_ASYMWUP initializes HU1:CBPM:HU27:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_ROSC initializes HU1:CBPM:HU27:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_ROSCTEST initializes HU1:CBPM:HU27:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_CSP initializes HU1:CBPM:HU27:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_BIAS_EN initializes HU1:CBPM:HU27:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_CP_EN initializes HU1:CBPM:HU27:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_PFD_EN initializes HU1:CBPM:HU27:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_REF_EN initializes HU1:CBPM:HU27:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_VCO_EN initializes HU1:CBPM:HU27:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_GPIO_EN initializes HU1:CBPM:HU27:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_LD_EN initializes HU1:CBPM:HU27:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_CLKDIG_EN initializes HU1:CBPM:HU27:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_DIV_EN initializes HU1:CBPM:HU27:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_DCYC_EN initializes HU1:CBPM:HU27:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_REFDIG_EN initializes HU1:CBPM:HU27:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_RDIVDIG_EN initializes HU1:CBPM:HU27:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_VCOSPI_EN initializes HU1:CBPM:HU27:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_PHASSEL initializes HU1:CBPM:HU27:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_PFDUP_EN initializes HU1:CBPM:HU27:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_PFDDN_EN initializes HU1:CBPM:HU27:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_PFDLD_EN initializes HU1:CBPM:HU27:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_PFDUP initializes HU1:CBPM:HU27:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_PFDDN initializes HU1:CBPM:HU27:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU27:PLL_PFDMUTE initializes HU1:CBPM:HU27:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU27:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU27:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU27:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU27:PLL_CSPCORR initializes HU1:CBPM:HU27:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU27:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU27:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU27:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU27:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU27:PLL_LKDW initializes HU1:CBPM:HU27:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU27:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU27:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU27:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU27:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU27:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU27:PLL_PFDDLY initializes HU1:CBPM:HU27:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU27:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU27:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU27:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU27:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU27:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU27:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU27:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU27:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU27:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU27:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU27:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU27:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU27:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU27:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU27:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU27:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU27:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU27:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU27:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU27:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU27:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU27:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU27:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU27:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU27:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU27:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU27:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU27:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU27:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU27:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU27:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU27:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU27:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU27:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU27:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU27:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU27:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU27:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU27:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU27:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU27:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU27:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU27:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU27:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU27:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU27:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU27:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU27:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU27:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU27:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU27:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU27:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU27:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU27:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU27:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU27:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU27:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU27:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU27:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU27:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU27:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU27:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU27:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU27:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU27:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU27:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU27:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU27:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU27:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU27:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU27:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU27:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU27:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU27:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU27:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU27:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU27:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU27:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU27:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU27:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU27:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU27:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU27:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU27:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU27:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU27:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU27:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU27:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU27:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU27:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU27:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU27:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU27:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU27:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU27:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU27:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU27:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU27:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU27:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU27:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU27:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU27:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU27:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU27:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU27:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU27:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU27:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU27:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU27:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU27:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU27:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU27:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU27:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU27:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU27:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU27:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU27:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU27:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU27:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU27:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU27:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU27:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU27:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU27:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU27:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU27:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU27:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU27:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU27:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU27:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU27:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU27:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU27:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU27:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU27:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU27:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU27:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU27:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU27:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU27:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU27:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU27:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU27:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU27:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU27:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU27:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU27:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU27:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU27:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU28:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar27")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU28:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU28:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc27,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU28:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg27,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU28:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU28:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU28:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU28:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU28:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU28:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr27,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU28:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU28:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU28:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU28:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU28:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU28:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU28:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr27,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU28:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU28:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU28:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU28:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU28:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU28:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU28:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr27,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU28:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU28:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU28:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU28:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU28:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU28:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU28:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr27,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU28:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU28:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU28:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU28:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU28:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar27")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU28:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar27")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU28:ATTY")  
}   

record(longin, "HU1:CBPM:HU28:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar27")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU28:ATTREF")  
}   

record(longin, "HU1:CBPM:HU28:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar27")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU28:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU28:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar27")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU28:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar27")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU28:PS_STA")
}

record(bi, "HU1:CBPM:HU28:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar27")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU28:LO_LTCH")
}

record(bi, "HU1:CBPM:HU28:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar27")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU28:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr27,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU28:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar27")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU28:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr27,rcvrSysReg(8,14,1),reg_io27")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU28:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr27,rcvrSysReg(6,8,1),reg_io27")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU28:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr27,rcvrSysReg(6,2,1),reg_io27")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU28:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar27")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar27")   
	field(FLNK, "HU1:CBPM:HU28:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU28:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar27")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU28:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU28:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU28:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU28:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU28:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU28:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU28:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU28:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU28:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU28:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU28:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU28:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU28:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU28:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU28:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU28:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU28:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr27,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU28:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar27")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU28:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU28:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar27")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU28:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU28:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar27")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU28:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU28:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar27")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU28:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU28:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar27")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU28:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU28:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar27")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU28:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU28:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar27")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU28:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU28:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar27")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU28:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU28:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar27")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU28:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar27")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU28:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU28:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar27")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU28:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU28:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar27")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU28:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU28:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar27")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU28:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU28:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar27")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU28:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU28:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar27")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU28:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU28:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar27")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU28:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU28:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar27")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU28:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU28:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll27,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU28:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU28:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU28:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU28:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU28:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU28:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU28:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU28:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU28:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU28:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU28:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU28:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU28:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU28:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU28:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU28:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU28:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU28:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU28:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU28:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU28:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU28:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU28:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU28:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU28:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU28:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU28:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU28:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU28:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU28:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU28:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU28:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU28:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU28:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU28:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU28:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU28:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU28:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU28:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU28:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU28:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU28:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU28:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU28:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU28:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU28:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU28:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU28:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU28:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU28:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU28:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU28:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU28:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU28:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU28:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU28:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU28:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU28:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU28:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU28:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU28:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU28:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU28:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU28:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU28:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU28:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU28:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU28:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU28:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU28:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU28:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU28:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU28:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU28:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU28:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU28:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU28:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU28:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU28:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU28:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU28:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU28:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU28:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU28:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU28:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU28:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU28:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU28:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU28:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU28:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU28:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU28:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU28:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_CHIP_PIN initializes HU1:CBPM:HU28:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_CHIP_SPI initializes HU1:CBPM:HU28:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_RST_CLKS initializes HU1:CBPM:HU28:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_RST_BIAS initializes HU1:CBPM:HU28:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_RST_PFD initializes HU1:CBPM:HU28:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_RST_CP initializes HU1:CBPM:HU28:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_RST_REF initializes HU1:CBPM:HU28:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_RST_VCO initializes HU1:CBPM:HU28:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_RST_IO initializes HU1:CBPM:HU28:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_FRAC_RST initializes HU1:CBPM:HU28:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_FRACBUFF_RST initializes HU1:CBPM:HU28:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_FRACBYP initializes HU1:CBPM:HU28:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_AUTOSEED initializes HU1:CBPM:HU28:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_FSK initializes HU1:CBPM:HU28:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_REFCLK initializes HU1:CBPM:HU28:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_INVCLK initializes HU1:CBPM:HU28:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_ILKD initializes HU1:CBPM:HU28:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_ASYMW initializes HU1:CBPM:HU28:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_ASYMWUP initializes HU1:CBPM:HU28:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_ROSC initializes HU1:CBPM:HU28:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_ROSCTEST initializes HU1:CBPM:HU28:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_CSP initializes HU1:CBPM:HU28:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_BIAS_EN initializes HU1:CBPM:HU28:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_CP_EN initializes HU1:CBPM:HU28:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_PFD_EN initializes HU1:CBPM:HU28:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_REF_EN initializes HU1:CBPM:HU28:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_VCO_EN initializes HU1:CBPM:HU28:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_GPIO_EN initializes HU1:CBPM:HU28:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_LD_EN initializes HU1:CBPM:HU28:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_CLKDIG_EN initializes HU1:CBPM:HU28:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_DIV_EN initializes HU1:CBPM:HU28:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_DCYC_EN initializes HU1:CBPM:HU28:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_REFDIG_EN initializes HU1:CBPM:HU28:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_RDIVDIG_EN initializes HU1:CBPM:HU28:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_VCOSPI_EN initializes HU1:CBPM:HU28:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_PHASSEL initializes HU1:CBPM:HU28:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_PFDUP_EN initializes HU1:CBPM:HU28:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_PFDDN_EN initializes HU1:CBPM:HU28:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_PFDLD_EN initializes HU1:CBPM:HU28:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_PFDUP initializes HU1:CBPM:HU28:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_PFDDN initializes HU1:CBPM:HU28:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU28:PLL_PFDMUTE initializes HU1:CBPM:HU28:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU28:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU28:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU28:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU28:PLL_CSPCORR initializes HU1:CBPM:HU28:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU28:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU28:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU28:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU28:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU28:PLL_LKDW initializes HU1:CBPM:HU28:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU28:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU28:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU28:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU28:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU28:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU28:PLL_PFDDLY initializes HU1:CBPM:HU28:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU28:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU28:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU28:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU28:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU28:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU28:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU28:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU28:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU28:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU28:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU28:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU28:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU28:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU28:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU28:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU28:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU28:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU28:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU28:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU28:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU28:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU28:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU28:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU28:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU28:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU28:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU28:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU28:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU28:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU28:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU28:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU28:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU28:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU28:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU28:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU28:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU28:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU28:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU28:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU28:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU28:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU28:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU28:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU28:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU28:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU28:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU28:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU28:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU28:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU28:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU28:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU28:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU28:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU28:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU28:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU28:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU28:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU28:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU28:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU28:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU28:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU28:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU28:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU28:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU28:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU28:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU28:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU28:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU28:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU28:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU28:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU28:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU28:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU28:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU28:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU28:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU28:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU28:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU28:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU28:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU28:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU28:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU28:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU28:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU28:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU28:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU28:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU28:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU28:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU28:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU28:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU28:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU28:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU28:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU28:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU28:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU28:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU28:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU28:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU28:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU28:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU28:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU28:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU28:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU28:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU28:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU28:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU28:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU28:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU28:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU28:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU28:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU28:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU28:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU28:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU28:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU28:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU28:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU28:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU28:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU28:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU28:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU28:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU28:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU28:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU28:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU28:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU28:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU28:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU28:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU28:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU28:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU28:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU28:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU28:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU28:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU28:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU28:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU28:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU28:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU28:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU28:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU28:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU28:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU28:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU28:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU28:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU28:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU28:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU29:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar28")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU29:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU29:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc28,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU29:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg28,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU29:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU29:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU29:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU29:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU29:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU29:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr28,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU29:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU29:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU29:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU29:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU29:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU29:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU29:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr28,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU29:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU29:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU29:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU29:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU29:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU29:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU29:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr28,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU29:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU29:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU29:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU29:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU29:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU29:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU29:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr28,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU29:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU29:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU29:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU29:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU29:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar28")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU29:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar28")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU29:ATTY")  
}   

record(longin, "HU1:CBPM:HU29:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar28")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU29:ATTREF")  
}   

record(longin, "HU1:CBPM:HU29:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar28")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU29:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU29:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar28")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU29:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar28")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU29:PS_STA")
}

record(bi, "HU1:CBPM:HU29:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar28")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU29:LO_LTCH")
}

record(bi, "HU1:CBPM:HU29:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar28")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU29:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr28,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU29:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar28")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU29:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr28,rcvrSysReg(8,14,1),reg_io28")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU29:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr28,rcvrSysReg(6,8,1),reg_io28")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU29:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr28,rcvrSysReg(6,2,1),reg_io28")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU29:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar28")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar28")   
	field(FLNK, "HU1:CBPM:HU29:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU29:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar28")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU29:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU29:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU29:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU29:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU29:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU29:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU29:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU29:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU29:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU29:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU29:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU29:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU29:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU29:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU29:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU29:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU29:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr28,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU29:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar28")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU29:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU29:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar28")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU29:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU29:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar28")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU29:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU29:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar28")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU29:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU29:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar28")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU29:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU29:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar28")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU29:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU29:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar28")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU29:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU29:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar28")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU29:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU29:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar28")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU29:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar28")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU29:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU29:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar28")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU29:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU29:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar28")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU29:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU29:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar28")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU29:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU29:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar28")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU29:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU29:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar28")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU29:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU29:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar28")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU29:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU29:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar28")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU29:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU29:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll28,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU29:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU29:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU29:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU29:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU29:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU29:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU29:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU29:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU29:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU29:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU29:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU29:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU29:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU29:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU29:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU29:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU29:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU29:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU29:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU29:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU29:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU29:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU29:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU29:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU29:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU29:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU29:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU29:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU29:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU29:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU29:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU29:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU29:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU29:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU29:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU29:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU29:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU29:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU29:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU29:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU29:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU29:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU29:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU29:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU29:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU29:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU29:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU29:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU29:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU29:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU29:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU29:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU29:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU29:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU29:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU29:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU29:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU29:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU29:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU29:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU29:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU29:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU29:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU29:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU29:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU29:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU29:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU29:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU29:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU29:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU29:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU29:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU29:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU29:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU29:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU29:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU29:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU29:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU29:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU29:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU29:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU29:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU29:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU29:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU29:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU29:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU29:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU29:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU29:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU29:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU29:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU29:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU29:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_CHIP_PIN initializes HU1:CBPM:HU29:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_CHIP_SPI initializes HU1:CBPM:HU29:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_RST_CLKS initializes HU1:CBPM:HU29:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_RST_BIAS initializes HU1:CBPM:HU29:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_RST_PFD initializes HU1:CBPM:HU29:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_RST_CP initializes HU1:CBPM:HU29:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_RST_REF initializes HU1:CBPM:HU29:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_RST_VCO initializes HU1:CBPM:HU29:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_RST_IO initializes HU1:CBPM:HU29:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_FRAC_RST initializes HU1:CBPM:HU29:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_FRACBUFF_RST initializes HU1:CBPM:HU29:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_FRACBYP initializes HU1:CBPM:HU29:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_AUTOSEED initializes HU1:CBPM:HU29:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_FSK initializes HU1:CBPM:HU29:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_REFCLK initializes HU1:CBPM:HU29:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_INVCLK initializes HU1:CBPM:HU29:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_ILKD initializes HU1:CBPM:HU29:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_ASYMW initializes HU1:CBPM:HU29:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_ASYMWUP initializes HU1:CBPM:HU29:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_ROSC initializes HU1:CBPM:HU29:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_ROSCTEST initializes HU1:CBPM:HU29:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_CSP initializes HU1:CBPM:HU29:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_BIAS_EN initializes HU1:CBPM:HU29:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_CP_EN initializes HU1:CBPM:HU29:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_PFD_EN initializes HU1:CBPM:HU29:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_REF_EN initializes HU1:CBPM:HU29:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_VCO_EN initializes HU1:CBPM:HU29:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_GPIO_EN initializes HU1:CBPM:HU29:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_LD_EN initializes HU1:CBPM:HU29:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_CLKDIG_EN initializes HU1:CBPM:HU29:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_DIV_EN initializes HU1:CBPM:HU29:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_DCYC_EN initializes HU1:CBPM:HU29:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_REFDIG_EN initializes HU1:CBPM:HU29:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_RDIVDIG_EN initializes HU1:CBPM:HU29:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_VCOSPI_EN initializes HU1:CBPM:HU29:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_PHASSEL initializes HU1:CBPM:HU29:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_PFDUP_EN initializes HU1:CBPM:HU29:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_PFDDN_EN initializes HU1:CBPM:HU29:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_PFDLD_EN initializes HU1:CBPM:HU29:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_PFDUP initializes HU1:CBPM:HU29:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_PFDDN initializes HU1:CBPM:HU29:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU29:PLL_PFDMUTE initializes HU1:CBPM:HU29:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU29:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU29:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU29:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU29:PLL_CSPCORR initializes HU1:CBPM:HU29:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU29:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU29:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU29:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU29:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU29:PLL_LKDW initializes HU1:CBPM:HU29:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU29:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU29:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU29:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU29:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU29:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU29:PLL_PFDDLY initializes HU1:CBPM:HU29:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU29:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU29:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU29:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU29:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU29:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU29:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU29:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU29:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU29:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU29:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU29:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU29:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU29:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU29:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU29:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU29:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU29:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU29:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU29:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU29:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU29:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU29:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU29:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU29:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU29:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU29:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU29:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU29:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU29:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU29:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU29:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU29:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU29:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU29:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU29:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU29:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU29:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU29:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU29:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU29:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU29:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU29:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU29:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU29:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU29:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU29:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU29:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU29:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU29:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU29:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU29:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU29:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU29:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU29:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU29:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU29:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU29:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU29:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU29:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU29:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU29:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU29:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU29:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU29:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU29:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU29:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU29:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU29:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU29:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU29:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU29:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU29:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU29:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU29:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU29:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU29:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU29:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU29:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU29:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU29:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU29:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU29:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU29:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU29:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU29:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU29:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU29:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU29:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU29:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU29:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU29:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU29:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU29:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU29:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU29:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU29:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU29:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU29:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU29:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU29:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU29:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU29:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU29:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU29:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU29:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU29:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU29:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU29:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU29:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU29:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU29:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU29:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU29:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU29:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU29:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU29:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU29:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU29:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU29:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU29:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU29:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU29:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU29:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU29:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU29:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU29:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU29:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU29:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU29:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU29:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU29:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU29:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU29:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU29:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU29:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU29:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU29:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU29:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU29:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU29:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU29:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU29:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU29:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU29:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU29:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU29:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU29:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU29:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU29:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU30:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar29")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU30:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU30:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc29,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU30:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg29,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU30:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU30:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU30:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU30:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU30:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU30:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr29,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU30:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU30:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU30:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU30:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU30:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU30:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU30:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr29,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU30:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU30:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU30:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU30:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU30:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU30:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU30:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr29,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU30:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU30:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU30:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU30:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU30:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU30:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU30:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr29,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU30:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU30:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU30:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU30:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU30:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar29")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU30:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar29")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU30:ATTY")  
}   

record(longin, "HU1:CBPM:HU30:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar29")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU30:ATTREF")  
}   

record(longin, "HU1:CBPM:HU30:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar29")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU30:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU30:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar29")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU30:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar29")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU30:PS_STA")
}

record(bi, "HU1:CBPM:HU30:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar29")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU30:LO_LTCH")
}

record(bi, "HU1:CBPM:HU30:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar29")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU30:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr29,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU30:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar29")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU30:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr29,rcvrSysReg(8,14,1),reg_io29")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU30:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr29,rcvrSysReg(6,8,1),reg_io29")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU30:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr29,rcvrSysReg(6,2,1),reg_io29")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU30:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar29")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar29")   
	field(FLNK, "HU1:CBPM:HU30:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU30:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar29")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU30:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU30:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU30:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU30:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU30:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU30:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU30:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU30:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU30:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU30:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU30:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU30:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU30:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU30:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU30:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU30:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU30:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr29,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU30:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar29")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU30:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU30:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar29")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU30:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU30:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar29")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU30:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU30:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar29")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU30:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU30:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar29")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU30:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU30:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar29")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU30:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU30:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar29")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU30:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU30:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar29")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU30:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU30:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar29")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU30:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar29")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU30:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU30:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar29")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU30:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU30:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar29")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU30:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU30:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar29")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU30:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU30:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar29")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU30:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU30:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar29")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU30:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU30:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar29")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU30:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU30:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar29")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU30:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU30:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll29,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU30:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU30:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU30:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU30:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU30:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU30:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU30:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU30:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU30:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU30:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU30:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU30:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU30:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU30:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU30:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU30:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU30:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU30:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU30:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU30:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU30:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU30:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU30:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU30:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU30:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU30:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU30:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU30:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU30:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU30:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU30:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU30:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU30:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU30:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU30:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU30:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU30:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU30:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU30:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU30:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU30:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU30:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU30:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU30:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU30:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU30:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU30:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU30:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU30:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU30:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU30:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU30:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU30:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU30:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU30:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU30:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU30:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU30:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU30:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU30:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU30:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU30:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU30:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU30:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU30:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU30:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU30:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU30:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU30:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU30:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU30:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU30:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU30:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU30:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU30:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU30:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU30:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU30:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU30:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU30:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU30:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU30:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU30:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU30:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU30:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU30:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU30:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU30:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU30:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU30:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU30:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU30:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU30:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_CHIP_PIN initializes HU1:CBPM:HU30:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_CHIP_SPI initializes HU1:CBPM:HU30:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_RST_CLKS initializes HU1:CBPM:HU30:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_RST_BIAS initializes HU1:CBPM:HU30:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_RST_PFD initializes HU1:CBPM:HU30:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_RST_CP initializes HU1:CBPM:HU30:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_RST_REF initializes HU1:CBPM:HU30:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_RST_VCO initializes HU1:CBPM:HU30:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_RST_IO initializes HU1:CBPM:HU30:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_FRAC_RST initializes HU1:CBPM:HU30:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_FRACBUFF_RST initializes HU1:CBPM:HU30:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_FRACBYP initializes HU1:CBPM:HU30:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_AUTOSEED initializes HU1:CBPM:HU30:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_FSK initializes HU1:CBPM:HU30:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_REFCLK initializes HU1:CBPM:HU30:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_INVCLK initializes HU1:CBPM:HU30:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_ILKD initializes HU1:CBPM:HU30:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_ASYMW initializes HU1:CBPM:HU30:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_ASYMWUP initializes HU1:CBPM:HU30:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_ROSC initializes HU1:CBPM:HU30:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_ROSCTEST initializes HU1:CBPM:HU30:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_CSP initializes HU1:CBPM:HU30:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_BIAS_EN initializes HU1:CBPM:HU30:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_CP_EN initializes HU1:CBPM:HU30:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_PFD_EN initializes HU1:CBPM:HU30:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_REF_EN initializes HU1:CBPM:HU30:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_VCO_EN initializes HU1:CBPM:HU30:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_GPIO_EN initializes HU1:CBPM:HU30:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_LD_EN initializes HU1:CBPM:HU30:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_CLKDIG_EN initializes HU1:CBPM:HU30:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_DIV_EN initializes HU1:CBPM:HU30:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_DCYC_EN initializes HU1:CBPM:HU30:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_REFDIG_EN initializes HU1:CBPM:HU30:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_RDIVDIG_EN initializes HU1:CBPM:HU30:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_VCOSPI_EN initializes HU1:CBPM:HU30:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_PHASSEL initializes HU1:CBPM:HU30:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_PFDUP_EN initializes HU1:CBPM:HU30:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_PFDDN_EN initializes HU1:CBPM:HU30:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_PFDLD_EN initializes HU1:CBPM:HU30:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_PFDUP initializes HU1:CBPM:HU30:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_PFDDN initializes HU1:CBPM:HU30:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU30:PLL_PFDMUTE initializes HU1:CBPM:HU30:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU30:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU30:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU30:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU30:PLL_CSPCORR initializes HU1:CBPM:HU30:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU30:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU30:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU30:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU30:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU30:PLL_LKDW initializes HU1:CBPM:HU30:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU30:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU30:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU30:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU30:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU30:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU30:PLL_PFDDLY initializes HU1:CBPM:HU30:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU30:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU30:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU30:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU30:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU30:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU30:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU30:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU30:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU30:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU30:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU30:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU30:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU30:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU30:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU30:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU30:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU30:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU30:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU30:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU30:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU30:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU30:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU30:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU30:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU30:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU30:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU30:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU30:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU30:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU30:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU30:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU30:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU30:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU30:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU30:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU30:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU30:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU30:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU30:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU30:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU30:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU30:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU30:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU30:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU30:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU30:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU30:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU30:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU30:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU30:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU30:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU30:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU30:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU30:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU30:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU30:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU30:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU30:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU30:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU30:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU30:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU30:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU30:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU30:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU30:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU30:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU30:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU30:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU30:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU30:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU30:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU30:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU30:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU30:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU30:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU30:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU30:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU30:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU30:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU30:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU30:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU30:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU30:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU30:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU30:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU30:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU30:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU30:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU30:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU30:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU30:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU30:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU30:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU30:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU30:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU30:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU30:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU30:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU30:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU30:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU30:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU30:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU30:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU30:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU30:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU30:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU30:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU30:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU30:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU30:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU30:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU30:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU30:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU30:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU30:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU30:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU30:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU30:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU30:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU30:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU30:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU30:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU30:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU30:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU30:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU30:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU30:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU30:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU30:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU30:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU30:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU30:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU30:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU30:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU30:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU30:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU30:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU30:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU30:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU30:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU30:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU30:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU30:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU30:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU30:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU30:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU30:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU30:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU30:ATTSPR_SET_SEL.L PP")
}
# Receiver reponds to requests
record(bi, "HU1:CBPM:HU31:RCVR_ONLN") {
	field(DTYP, "GenVar")
	field(SCAN, "I/O Intr")
	field(INP,  "#C38S0@RcvrVar30")
	field(ZNAM, "Offline")
	field(ZSV,  "MAJOR")
	field(ONAM, "Online")
	field(OSV,  "NO_ALARM")
}

# Receiver online status
# If 'OFFLINE', driver stops polling rcvr
record(mbbo, "HU1:CBPM:HU31:RCVR_ACCESS") {
  	field(DESC, "Rcvr On Line")
	field(SCAN, "1 second")
	field(DTYP, "BusAddress")
	field(DOL,  "HU1:CBPM:HU31:ACCESS MSI")
	field(OMSL, "closed_loop")
	field(OUT,  "#C0S0@RcvrAcc30,m8")
  	field(ZRVL, "1")
  	field(ZRST, "Running")
  	field(ZRSV, "NO_ALARM")
  	field(ONVL, "1")
  	field(ONST, "Maintenance")
  	field(ONSV, "MINOR")
  	field(TWVL, "1")
  	field(TWST, "Test")
  	field(TWSV, "MINOR")
  	field(THVL, "0")
  	field(THST, "OFFLINE")
  	field(THSV, "MAJOR")
  	field(RVAL, "0")
  	field(VAL,  "0")
  	field(PINI, "YES")
}

# Control debug messages
record(bo, "HU1:CBPM:HU31:RCVR_DBG") {
	field(DTYP, "BusAddress")
	field(OMSL, "supervisory")
	field(OUT,  "#C0S0@RcvrDbg30,m8")
	field(ZNAM, "Msgs off")
	field(ONAM, "Msgs on")
	field(VAL,  "0")
	field(PINI, "YES")
}

# Placeholder PV to be backward-compatible
# with other receiver software. Not actually used.
record(bo, "HU1:CBPM:HU31:RCVR_GAIN_OUT") {
  field(DESC, "Signal gain for restore")
  field(ZNAM, "High")
  field(ONAM, "Low")
  field(PINI, "YES")
}

# Attenuator ranges are 32 dB, registers are 6-bit
# 0-31.5 dB in steps of 1 bit = 0.5 dB
# Max value of 63 = 31.5 dB
# 5/12/2016 Sonya:
# Now only prototype version combines XY into single
# channel. Consider adding support to handle either case. 

# Used in gain-based value switching, see bpmParmsRcvr.db
record(longout,"HU1:CBPM:HU31:RCVRPARMSEL") {
		field(SCAN, "10 second")
		field(OMSL,"closed_loop")
        field(DOL, "HU1:CBPM:HU31:RCVR_GAIN CP")
}

# ATT*_SET PVs are used in gain-based value switching
# See bpmParmsRcvr.db
# Must FLNK to ATT*_SET_SEQ PVs for gain parameter val switching
record(longout, "HU1:CBPM:HU31:ATTX_SET") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU31:ATTX_SET_SEQ")
}

record(longout, "HU1:CBPM:HU31:ATTX_OUT") {
	field(DESC, "Rcvr X Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr30,rcvrBpmReg(1)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU, "0.5 dB")
	field(FLNK, "HU1:CBPM:HU31:ATTX_SET_FB")
}

# If the ATTX_OUT record updates its
# value then feed back into ATTX_SET
record(longout, "HU1:CBPM:HU31:ATTX_SET_FB") {
	field(DESC, "Rcvr X Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU31:ATTX_OUT")
	field(OUT, "HU1:CBPM:HU31:ATTX_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU31:ATTY_SET") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU31:ATTY_SET_SEQ")
}


record(longout, "HU1:CBPM:HU31:ATTY_OUT") {
	field(DESC, "Rcvr Y Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr30,rcvrBpmReg(2)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU31:ATTY_SET_FB")
}

# If the ATTY_OUT record updates its
# value then feed back into ATTY_SET
record(longout, "HU1:CBPM:HU31:ATTY_SET_FB") {
	field(DESC, "Rcvr Y Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU31:ATTY_OUT")
	field(OUT, "HU1:CBPM:HU31:ATTY_SET PP")
	field(EGU, "0.5 dB")
}

record(longout, "HU1:CBPM:HU31:ATTREF_SET") {
	field(DESC, "Rcvr REF Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU31:ATTREF_SET_SEQ")
}

record(longout, "HU1:CBPM:HU31:ATTREF_OUT") {
	field(DESC, "Rcvr Ref Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr30,rcvrBpmReg(3)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU31:ATTREF_SET_FB")
}

# If the ATTREF_OUT record updates its
# value then feed back into ATTREF_SET
record(longout, "HU1:CBPM:HU31:ATTREF_SET_FB") {
	field(DESC, "Rcvr REF Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU31:ATTREF_OUT")
	field(OUT, "HU1:CBPM:HU31:ATTREF_SET PP")
	field(EGU, "0.5 dB")
 }
 

record(longout, "HU1:CBPM:HU31:ATTSPR_SET") {
	field(DESC, "Rcvr spare Att")
	field(DTYP, "Soft Channel")
	field(EGU,  "0.5 dB")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(FLNK, "HU1:CBPM:HU31:ATTSPR_SET_SEQ")
}

record(longout, "HU1:CBPM:HU31:ATTSPR_OUT") {
	field(DESC, "Rcvr Spare Att")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr30,rcvrBpmReg(4)")
	field(VAL,  "63")
	field(LOPR, "0")
	field(HOPR, "63")
	field(DRVL, "0")
	field(DRVH, "63")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU31:ATTSPR_SET_FB")
}

# If the ATTSPR_OUT record updates its
# value then feed back into ATTSPR_SET
record(longout, "HU1:CBPM:HU31:ATTSPR_SET_FB") {
	field(DESC, "Rcvr SPR Att (FB)")
	field(OMSL, "closed_loop")
	field(DOL, "HU1:CBPM:HU31:ATTSPR_OUT")
	field(OUT, "HU1:CBPM:HU31:ATTSPR_SET PP")
	field(EGU, "0.5 dB")
}

record(longin, "HU1:CBPM:HU31:RCVR_CSR") {
	field(DESC, "Control/status reg")
	field(DTYP, "GenVar")
	field(INP,  "#C0S0@RcvrVar30")
	field(SCAN, "I/O Intr")
}

record(longin, "HU1:CBPM:HU31:ATTX") {   
	field(DESC, "X Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C1S0@RcvrVar30")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU31:ATTY")  
}   

record(longin, "HU1:CBPM:HU31:ATTY") {   
	field(DESC, "Y Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C2S0@RcvrVar30")
	field(SCAN, "I/O Intr") 
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU31:ATTREF")  
}   

record(longin, "HU1:CBPM:HU31:ATTREF") {   
	field(DESC, "Ref Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C3S0@RcvrVar30")
	field(EGU,  "0.5 dB")
	field(FLNK, "HU1:CBPM:HU31:ATTSPR")  
}   

record(longin, "HU1:CBPM:HU31:ATTSPR") {   
	field(DESC, "Spare Att Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C4S0@RcvrVar30")
	field(EGU,  "0.5 dB")
}   

record(bi, "HU1:CBPM:HU31:RCVR_LO_STA") {
	field(DESC, "PLL Lock Status")
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar30")
	field(ZNAM, "Not locked")
	field(ZSV,  "MINOR")
	field(ONAM, "Locked")
	field(OSV,  "NO_ALARM")
	field(MASK, "1")
	field(FLNK, "HU1:CBPM:HU31:PS_STA")
}

record(bi, "HU1:CBPM:HU31:PS_STA") {
	field(DESC, "Rcvr Power Supply Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar30")
	field(ZNAM, "Fault")
	field(ZSV,  "MAJOR")
	field(ONAM, "Ok")
	field(OSV,  "NO_ALARM")
	field(MASK, "2")
	field(FLNK, "HU1:CBPM:HU31:LO_LTCH")
}

record(bi, "HU1:CBPM:HU31:LO_LTCH") {
	field(DESC, "PLL Latched Lock Status")
	field(DTYP, "GenVar")   
	field(INP,  "#C0S0@RcvrVar30")
	field(ZNAM, "Locked")
	field(ZSV,  "NO_ALARM")
	field(ONAM, "Lock lost")
	field(OSV,  "MINOR")
	field(MASK, "4")
}

record(bo, "HU1:CBPM:HU31:LO_LTCH_RESET") {
	field(DESC, "PLL Latched Lock Reset")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@Rcvr30,rcvrBpmReg(0)")
	field(VAL,  "0")
	field(MASK, "0x4")
}

# System information
record(longin, "HU1:CBPM:HU31:RCVR_VERS") {   
	field(DESC, "Firmware Vers.")   
	field(SCAN, "I/O Intr")
	field(DTYP, "GenVar")   
	field(INP,  "#C39S0@RcvrVar30")   
	field(PINI, "YES")
}   

record(stringin, "HU1:CBPM:HU31:RCVR_VERS_DATE") {   
	field(DESC, "Firmware Vers. Date")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr30,rcvrSysReg(8,14,1),reg_io30")   
	field(PINI, "YES")
}   
   
record(stringin, "HU1:CBPM:HU31:RCVR_SYSID") {   
	field(DESC, "System ID")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr30,rcvrSysReg(6,8,1),reg_io30")   
	field(PINI, "YES")
}   
  
record(stringin, "HU1:CBPM:HU31:RCVR_SUBSYS") {   
	field(DESC, "Subsystem type")   
	field(SCAN, "I/O Intr")
	field(DTYP, "BusAddress")   
	field(INP,  "#C0S0@Rcvr30,rcvrSysReg(6,2,1),reg_io30")   
	field(PINI, "YES")
} 

# PLL register readback
record(longin, "HU1:CBPM:HU31:PLL_REG_ID") {   
	field(DESC, "PLL ID Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C14S0@RcvrVar30")
	field(SCAN, "I/O Intr") 
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_RST")  
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_RST") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "GenVar")   
	field(INP,  "#C15S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_REFDIV")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_REFDIV") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C16S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_FREQINT")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_FREQINT") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C17S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_FREQFRAC")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_FREQFRAC") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C18S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_SEED")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_SEED") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C19S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_CFG")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_CFG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C20S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_LKD")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_LKD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C21S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_ANLG")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_ANLG") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C22S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_CP")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_CP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C23S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_OPAMP")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_OPAMP") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C24S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_PFD")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_PFD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C25S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_VCO")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_VCO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C26S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_GPO")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_GPO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C27S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_SPR")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_SPR") {   
	field(DESC, "Unused")   
	field(DTYP, "GenVar")   
	field(INP,  "#C28S0@RcvrVar30")   
	field(FLNK, "HU1:CBPM:HU31:PLL_REG_LD")   
}   

record(longin, "HU1:CBPM:HU31:PLL_REG_LD") {   
	field(DESC, "PLL ID")   
	field(DTYP, "GenVar")   
	field(INP,  "#C29S0@RcvrVar30")  
}  

# PLL reset is the only PLL reg write that happens
# immediately. Other reg writes require user 
# to process PLL_REG_SET_GO record, which
# writes all PLL registers simultaneously
record(bo, "HU1:CBPM:HU31:PLL_RESET") {   
	field(DESC, "PLL Reset")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(0)")
	field(MASK,  "0")
}   

# PLL register setpoints
record(longout, "HU1:CBPM:HU31:PLL_REG_RST_SET") {   
	field(DESC, "PLL Reset Reg")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(1)")   
	field(VAL,  "0x86")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU31:PLL_REG_REFDIV_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(2)")   
	field(VAL,  "0x2")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU31:PLL_REG_FREQINT_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(3)")   
	field(VAL,  "0x5F")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU31:PLL_REG_FREQFRAC_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(4)")   
	field(VAL,  "0xA9F318")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU31:PLL_REG_SEED_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(5)")  
	field(VAL,  "0x6094") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU31:PLL_REG_CFG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(6)")   
	field(VAL,  "0x702F87")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU31:PLL_REG_LKD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(7)")   
	field(VAL,  "0x4FA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU31:PLL_REG_ANLG_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(8)")   
	field(VAL,  "0x31DF")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU31:PLL_REG_CP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(9)")   
	field(VAL,  "0x4BFE00")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU31:PLL_REG_OPAMP_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(10)")  
	field(VAL,  "0x0") 
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU31:PLL_REG_PFD_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(11)")   
	field(VAL,  "0x7A")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU31:PLL_REG_VCO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(12)") 
	field(VAL,  "0x0")  
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU31:PLL_REG_GPO_SET") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(13)")   
	field(VAL,  "0xA")
	field(PINI, "YES") 
	info(autosaveFields, "VAL")
}   

record(longout, "HU1:CBPM:HU31:PLL_REG_SPR_SET") {   
	field(DESC, "Unused")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(14)") 
	field(VAL,  "0x7")  
	field(PINI, "YES") 
}   

# Read-only register
#record(longout, "HU1:CBPM:HU31:PLL_REG_LD_SET") {   
#	field(DESC, "PLL ID")   
#	field(DTYP, "BusAddress")   
#	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(15)") 
#	field(VAL,  "0x1") 
#	field(PINI, "YES") 
#}  

# Write all PLL register setpoints to receiver
record(bo, "HU1:CBPM:HU31:PLL_REG_SET_GO") {   
	field(DESC, "PLL ID")   
	field(DTYP, "BusAddress")   
	field(OUT,  "#C0S0@Rcvr30,rcvrPllReg(-1)") 
	field(PINI, "YES") 
}  
 
# Xilinx FPGA monitoring
record(ai, "HU1:CBPM:HU31:FPGA_TEMP") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C5S0@RcvrVar30")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU31:FPGA_VINT")
} 

record(ai, "HU1:CBPM:HU31:FPGA_VINT") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C6S0@RcvrVar30")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU31:FPGA_VAUX")
} 

record(ai, "HU1:CBPM:HU31:FPGA_VAUX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C7S0@RcvrVar30")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU31:FPGA_TEMPMAX")
} 

record(ai, "HU1:CBPM:HU31:FPGA_TEMPMAX") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C8S0@RcvrVar30")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU31:FPGA_VINTMAX")
} 

record(ai, "HU1:CBPM:HU31:FPGA_VINTMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C9S0@RcvrVar30")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU31:FPGA_VAUXMAX")
} 

record(ai, "HU1:CBPM:HU31:FPGA_VAUXMAX") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C10S0@RcvrVar30")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU31:FPGA_TEMPMIN")
} 

record(ai, "HU1:CBPM:HU31:FPGA_TEMPMIN") {
	field(DESC, "Xilinx Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C11S0@RcvrVar30")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "-459.67")
	field(ASLO, ".013842")
	field(FLNK, "HU1:CBPM:HU31:FPGA_VINTMIN")
} 

record(ai, "HU1:CBPM:HU31:FPGA_VINTMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C12S0@RcvrVar30")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
	field(FLNK, "HU1:CBPM:HU31:FPGA_VAUXMIN")
} 

record(ai, "HU1:CBPM:HU31:FPGA_VAUXMIN") {
	field(DESC, "Xilinx Voltage")   
	field(DTYP, "GenVar")   
	field(INP,  "#C13S0@RcvrVar30")   
	field(EGU,  "V")
	field(LINR, "SLOPE")
	field(PREC, "3")
	field(ASLO, ".000045776")
} 


# PLL monitoring
record(ai, "HU1:CBPM:HU31:PLL_+6V") {
	field(DESC, "PLL +6.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C30S0@RcvrVar30")   
	field(SCAN, "I/O Intr")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00091554")
	field(FLNK, "HU1:CBPM:HU31:PLL_+5V_VCO")
} 

record(ai, "HU1:CBPM:HU31:PLL_+5V_VCO") {
	field(DESC, "PLL +5.0V VCO")   
	field(DTYP, "GenVar")   
	field(INP,  "#C31S0@RcvrVar30")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU31:PLL_+5V_CP")
} 

record(ai, "HU1:CBPM:HU31:PLL_+5V_CP") {
	field(DESC, "PLL +5.0V CP")   
	field(DTYP, "GenVar")   
	field(INP,  "#C32S0@RcvrVar30")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU31:PLL_+15V")
} 

record(ai, "HU1:CBPM:HU31:PLL_+15V") {
	field(DESC, "PLL +15.0V")   
	field(DTYP, "GenVar")   
	field(INP,  "#C33S0@RcvrVar30")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".0030121266")
	field(FLNK, "HU1:CBPM:HU31:PLL_+3_3V_A")
} 

record(ai, "HU1:CBPM:HU31:PLL_+3_3V_A") {
	field(DESC, "PLL +3.3V Analog")   
	field(DTYP, "GenVar")   
	field(INP,  "#C34S0@RcvrVar30")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "0")
	field(ASLO, ".00061036")
	field(FLNK, "HU1:CBPM:HU31:PLL_+3_3V_D")
} 

record(ai, "HU1:CBPM:HU31:PLL_+3_3V_D") {
	field(DESC, "PLL +3.3V Digital")   
	field(DTYP, "GenVar")   
	field(INP,  "#C35S0@RcvrVar30")   
	field(EGU,  "V")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "2.5")
	field(ASLO, ".00030518")
	field(FLNK, "HU1:CBPM:HU31:PLL_CHIPTEMP")
} 

record(ai, "HU1:CBPM:HU31:PLL_CHIPTEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C36S0@RcvrVar30")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
	field(FLNK, "HU1:CBPM:HU31:PLL_TEMP")
} 

record(ai, "HU1:CBPM:HU31:PLL_TEMP") {
	field(DESC, "PLL Chip Temp")   
	field(DTYP, "GenVar")   
	field(INP,  "#C37S0@RcvrVar30")   
	field(EGU,  "DegF")
	field(PREC, "1")
	field(LINR, "SLOPE")
	field(AOFF, "32")
	field(ASLO, ".1125")
} 

record(mbbo, "HU1:CBPM:HU31:RCVR_POLL_PERIOD") {
	field(DESC, "Receiver poll period")
	field(ZRST, "1 second")
	field(ZRVL, "1")	
	field(ONST, "2 seconds")
	field(ONVL, "2")	
	field(TWST, "10 seconds")
	field(TWVL, "10")
	field(THST, "1 minute")
	field(THVL, "60")
	field(VAL,  "2")
	field(PINI, "YES")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:RCVR_POLL")	
}

record(longout, "HU1:CBPM:HU31:RCVR_POLL") {
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S0@RcvrPoll30,m8")
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU31:RCVR_POLL_PERIOD.RVAL")
}	
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU31:PLL_DSM") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CFG CPP")
}	

record(mbbi, "HU1:CBPM:HU31:PLL_DSM_SET") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CFG_SET CP")
}	

record(mbbo, "HU1:CBPM:HU31:PLL_DSM_DES") {
	field(DESC, "DSM type")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "not used?")
	field(ZRVL, "0")
	field(ONST, "not used?")
	field(ONVL, "1")
	field(TWST, "2nd order?")
	field(TWVL, "2")
	field(THST, "3rd order?")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "8")
	field(NOBT, "2")
	field(MASK, "0x300")
	field(FLNK, "HU1:CBPM:HU31:PLL_DSM_CALC")
}	

record(calcout, "HU1:CBPM:HU31:PLL_DSM_CALC") {
	field(DESC, "Set DSM type bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET")
	field(INPB, "HU1:CBPM:HU31:PLL_DSM_DES.RVAL")
	field(INPC, "HU1:CBPM:HU31:PLL_DSM_DES.MASK")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_CFG_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU31:PLL_1SHOT") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU31:PLL_1SHOT_SET") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU31:PLL_1SHOT_DES") {
	field(DESC, "1 shot dura")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "?")
	field(ZRVL, "0")
	field(ONST, "?")
	field(ONVL, "1")
	field(TWST, "?")
	field(TWVL, "2")
	field(THST, "?")
	field(THVL, "3")
	field(FRST, "?")
	field(FRVL, "4")
	field(FVST, "?")
	field(FVVL, "5")
	field(SXST, "?")
	field(SXVL, "6")
	field(SVST, "?")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "14")
	field(NOBT, "3")
	field(MASK, "0x1C00")
	field(FLNK, "HU1:CBPM:HU31:PLL_1SHOT_CALC")
}	

record(calcout, "HU1:CBPM:HU31:PLL_1SHOT_CALC") {
	field(DESC, "Set 1 shot dura bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU31:PLL_1SHOT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU31:PLL_1SHOT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU31:PLL_ROSC_CFG") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_LKD CPP")
}	

record(mbbi, "HU1:CBPM:HU31:PLL_ROSC_CFG_SET") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_LKD_SET CP")
}	

record(mbbo, "HU1:CBPM:HU31:PLL_ROSC_CFG_DES") {
	field(DESC, "Ring osc cfg")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Fastest")
	field(ZRVL, "0")
	field(ONST, "Faster")
	field(ONVL, "1")
	field(TWST, "Slower")
	field(TWVL, "2")
	field(THST, "Slowest")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "17")
	field(NOBT, "2")
	field(MASK, "0x6000")
	field(FLNK, "HU1:CBPM:HU31:PLL_ROSC_CFG_CALC")
}	

record(calcout, "HU1:CBPM:HU31:PLL_ROSC_CFG_CALC") {
	field(DESC, "Set Ring osc cfg bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET")
	field(INPB, "HU1:CBPM:HU31:PLL_ROSC_CFG_DES.RVAL")
	field(INPC, "HU1:CBPM:HU31:PLL_ROSC_CFG_DES.MASK")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_LKD_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU31:PLL_CP_UPO") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU31:PLL_CP_UPO_SET") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU31:PLL_CP_UPO_DES") {
	field(DESC, "CP up offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "2")
	field(NOBT, "3")
	field(MASK, "0x1C")
	field(FLNK, "HU1:CBPM:HU31:PLL_CP_UPO_CALC")
}	

record(calcout, "HU1:CBPM:HU31:PLL_CP_UPO_CALC") {
	field(DESC, "Set CP up offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU31:PLL_CP_UPO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU31:PLL_CP_UPO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU31:PLL_CP_DNO") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU31:PLL_CP_DNO_SET") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU31:PLL_CP_DNO_DES") {
	field(DESC, "CP down offs")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "55 uA")
	field(ONVL, "1")
	field(TWST, "110 uA")
	field(TWVL, "2")
	field(THST, "165 uA")
	field(THVL, "3")
	field(FRST, "220 uA")
	field(FRVL, "4")
	field(FVST, "275 uA")
	field(FVVL, "5")
	field(SXST, "330 uA")
	field(SXVL, "6")
	field(SVST, "485 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "7")
	field(NOBT, "3")
	field(MASK, "0x1C0")
	field(FLNK, "HU1:CBPM:HU31:PLL_CP_DNO_CALC")
}	

record(calcout, "HU1:CBPM:HU31:PLL_CP_DNO_CALC") {
	field(DESC, "Set CP down offs bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU31:PLL_CP_DNO_DES.RVAL")
	field(INPC, "HU1:CBPM:HU31:PLL_CP_DNO_DES.MASK")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU31:PLL_CP_UPT") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU31:PLL_CP_UPT_SET") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU31:PLL_CP_UPT_DES") {
	field(DESC, "CP up trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "10")
	field(NOBT, "4")
	field(MASK, "0x3C00")
	field(FLNK, "HU1:CBPM:HU31:PLL_CP_UPT_CALC")
}	

record(calcout, "HU1:CBPM:HU31:PLL_CP_UPT_CALC") {
	field(DESC, "Set CP up trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU31:PLL_CP_UPT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU31:PLL_CP_UPT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU31:PLL_CP_DNT") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU31:PLL_CP_DNT_SET") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU31:PLL_CP_DNT_DES") {
	field(DESC, "CP down trim")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "7 uA")
	field(ONVL, "1")
	field(TWST, "14 uA")
	field(TWVL, "2")
	field(THST, "21 uA")
	field(THVL, "3")
	field(FRST, "28 uA")
	field(FRVL, "4")
	field(FVST, "35 uA")
	field(FVVL, "5")
	field(SXST, "42 uA")
	field(SXVL, "6")
	field(SVST, "49 uA")
	field(SVVL, "7")
	field(EIST, "56 uA")
	field(EIVL, "8")
	field(NIST, "63 uA")
	field(NIVL, "9")
	field(TEST, "70 uA")
	field(TEVL, "10")
	field(ELST, "77 uA")
	field(ELVL, "11")
	field(TVST, "84 uA")
	field(TVVL, "12")
	field(TTST, "91 uA")
	field(TTVL, "13")
	field(FTST, "98 uA")
	field(FTVL, "14")
	field(FFST, "105 uA")
	field(FFVL, "15")
	field(SHFT, "14")
	field(NOBT, "4")
	field(MASK, "0x3C000")
	field(FLNK, "HU1:CBPM:HU31:PLL_CP_DNT_CALC")
}	

record(calcout, "HU1:CBPM:HU31:PLL_CP_DNT_CALC") {
	field(DESC, "Set CP down trim bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU31:PLL_CP_DNT_DES.RVAL")
	field(INPC, "HU1:CBPM:HU31:PLL_CP_DNT_DES.MASK")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU31:PLL_CP_UPI") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU31:PLL_CP_UPI_SET") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU31:PLL_CP_UPI_DES") {
	field(DESC, "CP up current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "18")
	field(NOBT, "3")
	field(MASK, "0x1C0000")
	field(FLNK, "HU1:CBPM:HU31:PLL_CP_UPI_CALC")
}	

record(calcout, "HU1:CBPM:HU31:PLL_CP_UPI_CALC") {
	field(DESC, "Set CP up current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU31:PLL_CP_UPI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU31:PLL_CP_UPI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU31:PLL_CP_DNI") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CP CPP")
}	

record(mbbi, "HU1:CBPM:HU31:PLL_CP_DNI_SET") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_CP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU31:PLL_CP_DNI_DES") {
	field(DESC, "CP down current")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0 uA")
	field(ZRVL, "0")
	field(ONST, "500 uA")
	field(ONVL, "1")
	field(TWST, "1000 uA")
	field(TWVL, "2")
	field(THST, "1500 uA")
	field(THVL, "3")
	field(FRST, "2000 uA")
	field(FRVL, "4")
	field(FVST, "2000 uA")
	field(FVVL, "5")
	field(SXST, "2000 uA")
	field(SXVL, "6")
	field(SVST, "2000 uA")
	field(SVVL, "7")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "21")
	field(NOBT, "3")
	field(MASK, "0xE00000")
	field(FLNK, "HU1:CBPM:HU31:PLL_CP_DNI_CALC")
}	

record(calcout, "HU1:CBPM:HU31:PLL_CP_DNI_CALC") {
	field(DESC, "Set CP down current bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CP_SET")
	field(INPB, "HU1:CBPM:HU31:PLL_CP_DNI_DES.RVAL")
	field(INPC, "HU1:CBPM:HU31:PLL_CP_DNI_DES.MASK")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_CP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU31:PLL_OPAMP") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_OPAMP CPP")
}	

record(mbbi, "HU1:CBPM:HU31:PLL_OPAMP_SET") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_OPAMP_SET CP")
}	

record(mbbo, "HU1:CBPM:HU31:PLL_OPAMP_DES") {
	field(DESC, "Opamp bias sel")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "540 uA")
	field(ZRVL, "0")
	field(ONST, "689 uA")
	field(ONVL, "1")
	field(TWST, "943 uA")
	field(TWVL, "2")
	field(THST, "1503 uA")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "2")
	field(MASK, "0x3")
	field(FLNK, "HU1:CBPM:HU31:PLL_OPAMP_CALC")
}	

record(calcout, "HU1:CBPM:HU31:PLL_OPAMP_CALC") {
	field(DESC, "Set Opamp bias sel bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_OPAMP_SET")
	field(INPB, "HU1:CBPM:HU31:PLL_OPAMP_DES.RVAL")
	field(INPC, "HU1:CBPM:HU31:PLL_OPAMP_DES.MASK")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_OPAMP_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU31:PLL_GPOSEL") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU31:PLL_GPOSEL_SET") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU31:PLL_GPOSEL_DES") {
	field(DESC, "GPO select")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Clk VCO/RefDiv")
	field(ZRVL, "0")
	field(ONST, "PFD up/PFD dn")
	field(ONVL, "1")
	field(TWST, "Ref out/RefDiv out")
	field(TWVL, "2")
	field(THST, "Seed stby/Frac stby")
	field(THVL, "3")
	field(FRST, "Integ inbuff/Clk sd")
	field(FRVL, "4")
	field(FVST, "1shot trig/1shot pulse")
	field(FVVL, "5")
	field(SXST, "'0'/Ring osc")
	field(SXVL, "6")
	field(SVST, "CSP add/CSP sub")
	field(SVVL, "7")
	field(EIST, "PFD RefDiv/PFD VCODiv")
	field(EIVL, "8")
	field(NIST, "CSP corr/PFD sat")
	field(NIVL, "9")
	field(TEST, "GPO Test")
	field(TEVL, "10")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "0")
	field(NOBT, "4")
	field(MASK, "0xF")
	field(FLNK, "HU1:CBPM:HU31:PLL_GPOSEL_CALC")
}	

record(calcout, "HU1:CBPM:HU31:PLL_GPOSEL_CALC") {
	field(DESC, "Set GPO select bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU31:PLL_GPOSEL_DES.RVAL")
	field(INPC, "HU1:CBPM:HU31:PLL_GPOSEL_DES.MASK")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU31:PLL_GPOTEST") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU31:PLL_GPOTEST_SET") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU31:PLL_GPOTEST_DES") {
	field(DESC, "GPO test data")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "0")
	field(ZRVL, "0")
	field(ONST, "1")
	field(ONVL, "1")
	field(TWST, "2")
	field(TWVL, "2")
	field(THST, "3")
	field(THVL, "3")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "4")
	field(NOBT, "2")
	field(MASK, "0x30")
	field(FLNK, "HU1:CBPM:HU31:PLL_GPOTEST_CALC")
}	

record(calcout, "HU1:CBPM:HU31:PLL_GPOTEST_CALC") {
	field(DESC, "Set GPO test data bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU31:PLL_GPOTEST_DES.RVAL")
	field(INPC, "HU1:CBPM:HU31:PLL_GPOTEST_DES.MASK")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_GPO_SET PP")
}
# Database template to write to multi-bit settings for PLL registers 
# 
# <signal> reflects actual values read back from register
# <signal_SET> reflects values in register setpoints
# <signal_DES> reflects values to be written to register setpoints
# <signal_CALC> reads in current _SET value, modifies bits appropriately
# and writes the new value to _SET
#
# This scheme is used in order to allow the lower-level register PVs to 
# have sole access  to the registers. This simplifies save/restore and 
# removes the need to sync the low- and high-level PVs.
#
# On the user display, the user sees <signal>_SET while changing <signal>_DES. 
# <signal> is used to indicate that the setpint (_SET) does not match the 
# actual current register value
 
record(mbbi, "HU1:CBPM:HU31:PLL_SPICLK") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_GPO CPP")
}	

record(mbbi, "HU1:CBPM:HU31:PLL_SPICLK_SET") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(SCAN, "10 second")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(INP,  "HU1:CBPM:HU31:PLL_REG_GPO_SET CP")
}	

record(mbbo, "HU1:CBPM:HU31:PLL_SPICLK_DES") {
	field(DESC, "VCO SPI clock")
	field(DTYP, "Raw Soft Channel")
	field(ZRST, "Div by 1")
	field(ZRVL, "0")
	field(ONST, "Div by 4")
	field(ONVL, "1")
	field(TWST, "")
	field(TWVL, "")
	field(THST, "")
	field(THVL, "")
	field(FRST, "")
	field(FRVL, "")
	field(FVST, "")
	field(FVVL, "")
	field(SXST, "")
	field(SXVL, "")
	field(SVST, "")
	field(SVVL, "")
	field(EIST, "")
	field(EIVL, "")
	field(NIST, "")
	field(NIVL, "")
	field(TEST, "")
	field(TEVL, "")
	field(ELST, "")
	field(ELVL, "")
	field(TVST, "")
	field(TVVL, "")
	field(TTST, "")
	field(TTVL, "")
	field(FTST, "")
	field(FTVL, "")
	field(FFST, "")
	field(FFVL, "")
	field(SHFT, "6")
	field(NOBT, "1")
	field(MASK, "0x40")
	field(FLNK, "HU1:CBPM:HU31:PLL_SPICLK_CALC")
}	

record(calcout, "HU1:CBPM:HU31:PLL_SPICLK_CALC") {
	field(DESC, "Set VCO SPI clock bits")
	field(CALC, "(A & ~C) | B")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_GPO_SET")
	field(INPB, "HU1:CBPM:HU31:PLL_SPICLK_DES.RVAL")
	field(INPC, "HU1:CBPM:HU31:PLL_SPICLK_DES.MASK")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_CHIP_PIN initializes HU1:CBPM:HU31:PLL_CHIP_PIN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_CHIP_PIN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_CHIP_PIN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_CHIP_PIN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_CHIP_PIN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_CHIP_PIN_DES") {
	field(DESC, "Chip enable from pin")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_CHIP_PIN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_CHIP_PIN_CALC") {
        field(DESC, "Chip enable from pin")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_CHIP_PIN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_CHIP_SPI initializes HU1:CBPM:HU31:PLL_CHIP_SPI to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_CHIP_SPI_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_CHIP_SPI _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_CHIP_SPI") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_CHIP_SPI_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_CHIP_SPI_DES") {
	field(DESC, "Chip enable from SPI")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_CHIP_SPI_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_CHIP_SPI_CALC") {
        field(DESC, "Chip enable from SPI")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_CHIP_SPI_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_RST_CLKS initializes HU1:CBPM:HU31:PLL_RST_CLKS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_RST_CLKS_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_RST_CLKS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_RST_CLKS") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_RST_CLKS_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_RST_CLKS_DES") {
	field(DESC, "Keep dig clks on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_RST_CLKS_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_RST_CLKS_CALC") {
        field(DESC, "Keep dig clks on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_RST_CLKS_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_RST_BIAS initializes HU1:CBPM:HU31:PLL_RST_BIAS to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_RST_BIAS_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_RST_BIAS _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_RST_BIAS") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_RST_BIAS_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_RST_BIAS_DES") {
	field(DESC, "Keep bias on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_RST_BIAS_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_RST_BIAS_CALC") {
        field(DESC, "Keep bias on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_RST_BIAS_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_RST_PFD initializes HU1:CBPM:HU31:PLL_RST_PFD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_RST_PFD_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_RST_PFD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_RST_PFD") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_RST_PFD_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_RST_PFD_DES") {
	field(DESC, "Keep PFD block on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_RST_PFD_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_RST_PFD_CALC") {
        field(DESC, "Keep PFD block on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_RST_PFD_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_RST_CP initializes HU1:CBPM:HU31:PLL_RST_CP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_RST_CP_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_RST_CP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_RST_CP") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_RST_CP_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_RST_CP_DES") {
	field(DESC, "Chip charge pump on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_RST_CP_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_RST_CP_CALC") {
        field(DESC, "Chip charge pump on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_RST_CP_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_RST_REF initializes HU1:CBPM:HU31:PLL_RST_REF to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_RST_REF_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_RST_REF _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_RST_REF") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_RST_REF_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_RST_REF_DES") {
	field(DESC, "Keep ref path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_RST_REF_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_RST_REF_CALC") {
        field(DESC, "Keep ref path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_RST_REF_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_RST_VCO initializes HU1:CBPM:HU31:PLL_RST_VCO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_RST_VCO_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_RST_VCO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_RST_VCO") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_RST_VCO_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_RST_VCO_DES") {
	field(DESC, "Keep VCO path buff on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_RST_VCO_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_RST_VCO_CALC") {
        field(DESC, "Keep VCO path buff on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_RST_VCO_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_RST_IO initializes HU1:CBPM:HU31:PLL_RST_IO to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_RST_IO_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_RST_IO _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_RST_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_RST_IO") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_RST_IO_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_RST_IO_DES") {
	field(DESC, "Keep digital I/O on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_RST_IO_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_RST_IO_CALC") {
        field(DESC, "Keep digital I/O on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_RST_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_RST_IO_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_RST_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_FRAC_RST initializes HU1:CBPM:HU31:PLL_FRAC_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_FRAC_RST_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_FRAC_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_FRAC_RST") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_FRAC_RST_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_FRAC_RST_DES") {
	field(DESC, "Frac reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_FRAC_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_FRAC_RST_CALC") {
        field(DESC, "Frac reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_FRAC_RST_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_FRACBUFF_RST initializes HU1:CBPM:HU31:PLL_FRACBUFF_RST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_FRACBUFF_RST_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_FRACBUFF_RST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_FRACBUFF_RST") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_FRACBUFF_RST_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_FRACBUFF_RST_DES") {
	field(DESC, "Frac buffers reset")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_FRACBUFF_RST_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_FRACBUFF_RST_CALC") {
        field(DESC, "Frac buffers reset")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_FRACBUFF_RST_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_FRACBYP initializes HU1:CBPM:HU31:PLL_FRACBYP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_FRACBYP_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_FRACBYP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_FRACBYP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_FRACBYP_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_FRACBYP_DES") {
	field(DESC, "Frac mod test mode")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_FRACBYP_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_FRACBYP_CALC") {
        field(DESC, "Frac mod test mode")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_FRACBYP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_AUTOSEED initializes HU1:CBPM:HU31:PLL_AUTOSEED to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_AUTOSEED_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_AUTOSEED _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_AUTOSEED") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_AUTOSEED_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_AUTOSEED_DES") {
	field(DESC, "Autoseed enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_AUTOSEED_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_AUTOSEED_CALC") {
        field(DESC, "Autoseed enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_AUTOSEED_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_FSK initializes HU1:CBPM:HU31:PLL_FSK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_FSK_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_FSK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_FSK") {
	field(CALC, "(A & ( 1 << 15)) >> 15")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_FSK_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_FSK_DES") {
	field(DESC, "FSK enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_FSK_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_FSK_CALC") {
        field(DESC, "FSK enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_FSK_DES")
	field(INPC, "15")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_REFCLK initializes HU1:CBPM:HU31:PLL_REFCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_REFCLK_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_REFCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_REFCLK") {
	field(CALC, "(A & ( 1 << 17)) >> 17")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_REFCLK_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_REFCLK_DES") {
	field(DESC, "Ref clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_REFCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_REFCLK_CALC") {
        field(DESC, "Ref clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_REFCLK_DES")
	field(INPC, "17")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_INVCLK initializes HU1:CBPM:HU31:PLL_INVCLK to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_INVCLK_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_INVCLK _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_INVCLK") {
	field(CALC, "(A & ( 1 << 18)) >> 18")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_INVCLK_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_INVCLK_DES") {
	field(DESC, "Invert clk")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_INVCLK_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_INVCLK_CALC") {
        field(DESC, "Invert clk")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_INVCLK_DES")
	field(INPC, "18")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_CFG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_ILKD initializes HU1:CBPM:HU31:PLL_ILKD to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_ILKD_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_ILKD _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_ILKD") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_ILKD_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_ILKD_DES") {
	field(DESC, "Intern lock detect")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_ILKD_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_ILKD_CALC") {
        field(DESC, "Intern lock detect")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_ILKD_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_ASYMW initializes HU1:CBPM:HU31:PLL_ASYMW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_ASYMW_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_ASYMW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_ASYMW") {
	field(CALC, "(A & ( 1 << 11)) >> 11")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_ASYMW_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_ASYMW_DES") {
	field(DESC, "Asym wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_ASYMW_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_ASYMW_CALC") {
        field(DESC, "Asym wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_ASYMW_DES")
	field(INPC, "11")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_ASYMWUP initializes HU1:CBPM:HU31:PLL_ASYMWUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_ASYMWUP_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_ASYMWUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_ASYMWUP") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_ASYMWUP_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_ASYMWUP_DES") {
	field(DESC, "Asym up wndw enbl")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_ASYMWUP_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_ASYMWUP_CALC") {
        field(DESC, "Asym up wndw enbl")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_ASYMWUP_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_ROSC initializes HU1:CBPM:HU31:PLL_ROSC to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_ROSC_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_ROSC _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_ROSC") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_ROSC_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_ROSC_DES") {
	field(DESC, "Ring osc/1-shot")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_ROSC_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_ROSC_CALC") {
        field(DESC, "Ring osc/1-shot")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_ROSC_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_ROSCTEST initializes HU1:CBPM:HU31:PLL_ROSCTEST to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_ROSCTEST_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_ROSCTEST _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_ROSCTEST") {
	field(CALC, "(A & ( 1 << 19)) >> 19")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_ROSCTEST_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_ROSCTEST_DES") {
	field(DESC, "Ring osc test")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_ROSCTEST_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_ROSCTEST_CALC") {
        field(DESC, "Ring osc test")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_ROSCTEST_DES")
	field(INPC, "19")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_CSP initializes HU1:CBPM:HU31:PLL_CSP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_CSP_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_CSP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_CSP") {
	field(CALC, "(A & ( 1 << 20)) >> 20")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_CSP_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_CSP_DES") {
	field(DESC, "CSP Enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_CSP_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_CSP_CALC") {
        field(DESC, "CSP Enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_CSP_DES")
	field(INPC, "20")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_LKD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_BIAS_EN initializes HU1:CBPM:HU31:PLL_BIAS_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_BIAS_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_BIAS_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_BIAS_EN") {
	field(CALC, "(A & ( 1 << 0)) >> 0")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_BIAS_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_BIAS_EN_DES") {
	field(DESC, "Bias enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_BIAS_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_BIAS_EN_CALC") {
        field(DESC, "Bias enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_BIAS_EN_DES")
	field(INPC, "0")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_CP_EN initializes HU1:CBPM:HU31:PLL_CP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_CP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_CP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_CP_EN") {
	field(CALC, "(A & ( 1 << 1)) >> 1")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_CP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_CP_EN_DES") {
	field(DESC, "Charge pump enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_CP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_CP_EN_CALC") {
        field(DESC, "Charge pump enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_CP_EN_DES")
	field(INPC, "1")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_PFD_EN initializes HU1:CBPM:HU31:PLL_PFD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_PFD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_PFD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_PFD_EN") {
	field(CALC, "(A & ( 1 << 2)) >> 2")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_PFD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_PFD_EN_DES") {
	field(DESC, "PFD enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_PFD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_PFD_EN_CALC") {
        field(DESC, "PFD enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_PFD_EN_DES")
	field(INPC, "2")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_REF_EN initializes HU1:CBPM:HU31:PLL_REF_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_REF_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_REF_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_REF_EN") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_REF_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_REF_EN_DES") {
	field(DESC, "Ref path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_REF_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_REF_EN_CALC") {
        field(DESC, "Ref path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_REF_EN_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_VCO_EN initializes HU1:CBPM:HU31:PLL_VCO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_VCO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_VCO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_VCO_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_VCO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_VCO_EN_DES") {
	field(DESC, "VCO path buff enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_VCO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_VCO_EN_CALC") {
        field(DESC, "VCO path buff enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_VCO_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_GPIO_EN initializes HU1:CBPM:HU31:PLL_GPIO_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_GPIO_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_GPIO_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_GPIO_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_GPIO_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_GPIO_EN_DES") {
	field(DESC, "GPIO pads enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_GPIO_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_GPIO_EN_CALC") {
        field(DESC, "GPIO pads enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_GPIO_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_LD_EN initializes HU1:CBPM:HU31:PLL_LD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_LD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_LD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_LD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_LD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_LD_EN_DES") {
	field(DESC, "Lck det/Serial enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_LD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_LD_EN_CALC") {
        field(DESC, "Lck det/Serial enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_LD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_CLKDIG_EN initializes HU1:CBPM:HU31:PLL_CLKDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_CLKDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_CLKDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_CLKDIG_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_CLKDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_CLKDIG_EN_DES") {
	field(DESC, "VCO div clk->dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_CLKDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_CLKDIG_EN_CALC") {
        field(DESC, "VCO div clk->dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_CLKDIG_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_DIV_EN initializes HU1:CBPM:HU31:PLL_DIV_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_DIV_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_DIV_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_DIV_EN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_DIV_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_DIV_EN_DES") {
	field(DESC, "VCO div enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_DIV_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_DIV_EN_CALC") {
        field(DESC, "VCO div enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_DIV_EN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_DCYC_EN initializes HU1:CBPM:HU31:PLL_DCYC_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_DCYC_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_DCYC_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_DCYC_EN") {
	field(CALC, "(A & ( 1 << 10)) >> 10")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_DCYC_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_DCYC_EN_DES") {
	field(DESC, "VCO div duty cycle")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_DCYC_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_DCYC_EN_CALC") {
        field(DESC, "VCO div duty cycle")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_DCYC_EN_DES")
	field(INPC, "10")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_REFDIG_EN initializes HU1:CBPM:HU31:PLL_REFDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_REFDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_REFDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_REFDIG_EN") {
	field(CALC, "(A & ( 1 << 12)) >> 12")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_REFDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_REFDIG_EN_DES") {
	field(DESC, "Ref to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_REFDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_REFDIG_EN_CALC") {
        field(DESC, "Ref to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_REFDIG_EN_DES")
	field(INPC, "12")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_RDIVDIG_EN initializes HU1:CBPM:HU31:PLL_RDIVDIG_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_RDIVDIG_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_RDIVDIG_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_ANLG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_RDIVDIG_EN") {
	field(CALC, "(A & ( 1 << 13)) >> 13")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_RDIVDIG_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_RDIVDIG_EN_DES") {
	field(DESC, "Ref div to dig enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_RDIVDIG_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_RDIVDIG_EN_CALC") {
        field(DESC, "Ref div to dig enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_ANLG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_RDIVDIG_EN_DES")
	field(INPC, "13")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_ANLG_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_VCOSPI_EN initializes HU1:CBPM:HU31:PLL_VCOSPI_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_VCOSPI_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_VCOSPI_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_GPO_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_VCOSPI_EN") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_GPO_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_VCOSPI_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_VCOSPI_EN_DES") {
	field(DESC, "VCO to SPI enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_VCOSPI_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_VCOSPI_EN_CALC") {
        field(DESC, "VCO to SPI enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_GPO_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_VCOSPI_EN_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_GPO_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_PHASSEL initializes HU1:CBPM:HU31:PLL_PHASSEL to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_PHASSEL_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_PHASSEL _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_PHASSEL") {
	field(CALC, "(A & ( 1 << 3)) >> 3")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_PHASSEL_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_PHASSEL_DES") {
	field(DESC, "PFD input select")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_PHASSEL_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_PHASSEL_CALC") {
        field(DESC, "PFD input select")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_PHASSEL_DES")
	field(INPC, "3")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_PFDUP_EN initializes HU1:CBPM:HU31:PLL_PFDUP_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_PFDUP_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_PFDUP_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_PFDUP_EN") {
	field(CALC, "(A & ( 1 << 4)) >> 4")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_PFDUP_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_PFDUP_EN_DES") {
	field(DESC, "PFD up enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_PFDUP_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_PFDUP_EN_CALC") {
        field(DESC, "PFD up enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_PFDUP_EN_DES")
	field(INPC, "4")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_PFDDN_EN initializes HU1:CBPM:HU31:PLL_PFDDN_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_PFDDN_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_PFDDN_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_PFDDN_EN") {
	field(CALC, "(A & ( 1 << 5)) >> 5")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_PFDDN_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_PFDDN_EN_DES") {
	field(DESC, "PFD dn enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_PFDDN_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_PFDDN_EN_CALC") {
        field(DESC, "PFD dn enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_PFDDN_EN_DES")
	field(INPC, "5")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_PFDLD_EN initializes HU1:CBPM:HU31:PLL_PFDLD_EN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_PFDLD_EN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_PFDLD_EN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_PFDLD_EN") {
	field(CALC, "(A & ( 1 << 6)) >> 6")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_PFDLD_EN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_PFDLD_EN_DES") {
	field(DESC, "PFD lk detect out enable")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_PFDLD_EN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_PFDLD_EN_CALC") {
        field(DESC, "PFD lk detect out enable")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_PFDLD_EN_DES")
	field(INPC, "6")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_PFDUP initializes HU1:CBPM:HU31:PLL_PFDUP to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_PFDUP_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_PFDUP _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_PFDUP") {
	field(CALC, "(A & ( 1 << 7)) >> 7")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_PFDUP_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_PFDUP_DES") {
	field(DESC, "PFD up output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_PFDUP_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_PFDUP_CALC") {
        field(DESC, "PFD up output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_PFDUP_DES")
	field(INPC, "7")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_PFDDN initializes HU1:CBPM:HU31:PLL_PFDDN to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_PFDDN_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_PFDDN _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_PFDDN") {
	field(CALC, "(A & ( 1 << 8)) >> 8")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_PFDDN_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_PFDDN_DES") {
	field(DESC, "PFD down output on")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_PFDDN_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_PFDDN_CALC") {
        field(DESC, "PFD down output on")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_PFDDN_DES")
	field(INPC, "8")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_PFD_SET PP")
}
# Database template to write single PLL register bit
# 
# HU1:CBPM:HU31:PLL_PFDMUTE initializes HU1:CBPM:HU31:PLL_PFDMUTE to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_PFDMUTE_DES is the setpoint for this bit
# HU1:CBPM:HU31:PLL_PFDMUTE _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# register PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_PFDMUTE") {
	field(CALC, "(A & ( 1 << 9)) >> 9")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_PFDMUTE_DES PP")
}

record(bo, "HU1:CBPM:HU31:PLL_PFDMUTE_DES") {
	field(DESC, "PFD up/dn lock...")
	field(OMSL, "supervisory")
	field(FLNK, "HU1:CBPM:HU31:PLL_PFDMUTE_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_PFDMUTE_CALC") {
        field(DESC, "PFD up/dn lock...")
        field(CALC, "(A & ~( 1 << C )) | B << C")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_PFDMUTE_DES")
	field(INPC, "9")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_PFD_SET PP")
}
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU31:PLL_CSPCORR initializes HU1:CBPM:HU31:PLL_CSPCORR to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_CSPCORR_DES is the setpoint for this range of register bits
# HU1:CBPM:HU31:PLL_CSPCORR _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_CFG_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_CSPCORR") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET CPP")
        field(INPC, "0xF00000")
	field(INPD, "20")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_CSPCORR_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU31:PLL_CSPCORR_DES") {
	field(DESC, "Set CSPCORR bits")
	field(OMSL, "supervisory")
	field(DRVH, "0xF")
	field(FLNK, "HU1:CBPM:HU31:PLL_CSPCORR_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_CSPCORR_CALC") {
        field(DESC, "Set CSPCORR bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_CSPCORR_DES")
        field(INPC, "0xF00000")
	field(INPD, "20")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_CFG_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU31:PLL_CSPCORR") {
#	field(DESC, "Read CSPCORR bits")
#	field(CALC, "A & 0xF00000")
#	field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU31:PLL_LKDW initializes HU1:CBPM:HU31:PLL_LKDW to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_LKDW_DES is the setpoint for this range of register bits
# HU1:CBPM:HU31:PLL_LKDW _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_LKD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_LKDW") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET CPP")
        field(INPC, "0x3FF")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_LKDW_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU31:PLL_LKDW_DES") {
	field(DESC, "Set LKDW bits")
	field(OMSL, "supervisory")
	field(DRVH, "0x3FF")
	field(FLNK, "HU1:CBPM:HU31:PLL_LKDW_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_LKDW_CALC") {
        field(DESC, "Set LKDW bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_LKDW_DES")
        field(INPC, "0x3FF")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_LKD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU31:PLL_LKDW") {
#	field(DESC, "Read LKDW bits")
#	field(CALC, "A & 0x3FF")
#	field(INPA, "HU1:CBPM:HU31:PLL_REG_LKD CPP")
#}
 
# Database template to write to range of PLL register bits
# 
# HU1:CBPM:HU31:PLL_PFDDLY initializes HU1:CBPM:HU31:PLL_PFDDLY to actual register
# setpoint and keeps it synched
# HU1:CBPM:HU31:PLL_PFDDLY_DES is the setpoint for this range of register bits
# HU1:CBPM:HU31:PLL_PFDDLY _CALC reads in the current setpoint, modifies
# the value and writes it back out
# 
# This scheme allows users to write to either the low-level
# registe PVs or these. Their values are synched and only
# REG_PFD_SET needs to be save/restored

record(calcout, "HU1:CBPM:HU31:PLL_PFDDLY") {
	field(CALC, "(A & C) >> D")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET CPP")
        field(INPC, "0x7")
	field(INPD, "0")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_PFDDLY_DES PP")
	field(PINI, "YES")
}

record(longout, "HU1:CBPM:HU31:PLL_PFDDLY_DES") {
	field(DESC, "Set PFDDLY bits")
	field(OMSL, "supervisory")
	field(DRVH, "7")
	field(FLNK, "HU1:CBPM:HU31:PLL_PFDDLY_CALC")
} 

record(calcout, "HU1:CBPM:HU31:PLL_PFDDLY_CALC") {
        field(DESC, "Set PFDDLY bits")
        field(CALC, "(A & ~C) | B << D")
        field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD_SET")
        field(INPB, "HU1:CBPM:HU31:PLL_PFDDLY_DES")
        field(INPC, "0x7")
	field(INPD, "0")
        field(OUT,  "HU1:CBPM:HU31:PLL_REG_PFD_SET PP")
}

# Is this record needed?
#record(calc, "HU1:CBPM:HU31:PLL_PFDDLY") {
#	field(DESC, "Read PFDDLY bits")
#	field(CALC, "A & 0x7")
#	field(INPA, "HU1:CBPM:HU31:PLL_REG_PFD CPP")
#}
 
# Frequency fractional part register
#------------------------------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_FREQFRAC_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU31:PLL_FREQFRAC_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_FREQFRAC_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_FREQFRAC CPP")
}

# For user to enter fractional freq factor
# Then is converted to register setting
record(ao, "HU1:CBPM:HU31:PLL_FREQFRAC") {
	field(DESC, "Freq frac factor")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU31:PLL_FREQFRAC_CONV PP")
} 

record(calcout, "HU1:CBPM:HU31:PLL_FREQFRAC_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU31:PLL_FREQFRAC")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_FREQFRAC_SET PP")
}

# Seed register
#--------------
# Initialize to actual register setpoint on boot
# (Then only PLL_REG_SEED_SET needs to be save/restored)
record(calcout, "HU1:CBPM:HU31:PLL_SEED_INIT") {
	field(CALC, "A / 2^24")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_SEED_SET CPP")
	field(PINI, "YES")
	field(OOPT, "On Change")
	field(OUT, "HU1:CBPM:HU31:PLL_SEED CPP")
}

# For user to enter fractional seed
# Then is converted to register setting
record(ao, "HU1:CBPM:HU31:PLL_SEED") {
	field(DESC, "Seed")
	field(OMSL, "supervisory")
	field(PREC, "20")
	field(FLNK,  "HU1:CBPM:HU31:PLL_SEED_CONV PP")
} 

record(calcout, "HU1:CBPM:HU31:PLL_SEED_CONV") {
	field(DESC, "Convert freq frac for reg")
	field(CALC, "A * 2^24")
	field(INPA, "HU1:CBPM:HU31:PLL_SEED")
	field(OUT,  "HU1:CBPM:HU31:PLL_REG_SEED_SET PP")
}

# DSM Max and Min
#----------------
record(calc, "HU1:CBPM:HU31:PLL_DSM_MAX") {
	field(DESC, "DSM Max read-only")
	field(CALC, "A & 0xF")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG CPP")
}

record(calc, "HU1:CBPM:HU31:PLL_DSM_MIN") {
	field(DESC, "DSM Min read-only")
	field(CALC, "(A & 0xF0) >> 4")
	field(INPA, "HU1:CBPM:HU31:PLL_REG_CFG CPP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU31:ATTX_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU31:ATTX_SET")
	field(DOL2, "HU1:CBPM:HU31:ATTX_SET")
	field(DOL3, "HU1:CBPM:HU31:ATTX_SET")
	field(DOL4, "HU1:CBPM:HU31:ATTX_SET")
	field(DOL5, "HU1:CBPM:HU31:ATTX_SET")
	field(DOL6, "HU1:CBPM:HU31:ATTX_SET")
	field(DOL7, "HU1:CBPM:HU31:ATTX_SET")
	field(DOL8, "HU1:CBPM:HU31:ATTX_SET")
	field(DOL9, "HU1:CBPM:HU31:ATTX_SET")
	field(DOLA, "HU1:CBPM:HU31:ATTX_SET")
	field(LNK1, "HU1:CBPM:HU31:ATTX_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU31:ATTX_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU31:ATTX_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU31:ATTX_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU31:ATTX_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU31:ATTX_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU31:ATTX_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU31:ATTX_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU31:ATTX_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU31:ATTX_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU31:ATTX_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU31:ATTX_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU31:ATTX_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU31:ATTX_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU31:ATTX_SET_SEL")
	field(OUTA, "HU1:CBPM:HU31:ATTX_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU31:ATTX_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU31:ATTX_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU31:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU31:ATTX_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU31:ATTY_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU31:ATTY_SET")
	field(DOL2, "HU1:CBPM:HU31:ATTY_SET")
	field(DOL3, "HU1:CBPM:HU31:ATTY_SET")
	field(DOL4, "HU1:CBPM:HU31:ATTY_SET")
	field(DOL5, "HU1:CBPM:HU31:ATTY_SET")
	field(DOL6, "HU1:CBPM:HU31:ATTY_SET")
	field(DOL7, "HU1:CBPM:HU31:ATTY_SET")
	field(DOL8, "HU1:CBPM:HU31:ATTY_SET")
	field(DOL9, "HU1:CBPM:HU31:ATTY_SET")
	field(DOLA, "HU1:CBPM:HU31:ATTY_SET")
	field(LNK1, "HU1:CBPM:HU31:ATTY_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU31:ATTY_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU31:ATTY_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU31:ATTY_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU31:ATTY_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU31:ATTY_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU31:ATTY_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU31:ATTY_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU31:ATTY_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU31:ATTY_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU31:ATTY_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU31:ATTY_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU31:ATTY_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU31:ATTY_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU31:ATTY_SET_SEL")
	field(OUTA, "HU1:CBPM:HU31:ATTY_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU31:ATTY_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU31:ATTY_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU31:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU31:ATTY_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU31:ATTREF_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU31:ATTREF_SET")
	field(DOL2, "HU1:CBPM:HU31:ATTREF_SET")
	field(DOL3, "HU1:CBPM:HU31:ATTREF_SET")
	field(DOL4, "HU1:CBPM:HU31:ATTREF_SET")
	field(DOL5, "HU1:CBPM:HU31:ATTREF_SET")
	field(DOL6, "HU1:CBPM:HU31:ATTREF_SET")
	field(DOL7, "HU1:CBPM:HU31:ATTREF_SET")
	field(DOL8, "HU1:CBPM:HU31:ATTREF_SET")
	field(DOL9, "HU1:CBPM:HU31:ATTREF_SET")
	field(DOLA, "HU1:CBPM:HU31:ATTREF_SET")
	field(LNK1, "HU1:CBPM:HU31:ATTREF_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU31:ATTREF_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU31:ATTREF_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU31:ATTREF_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU31:ATTREF_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU31:ATTREF_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU31:ATTREF_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU31:ATTREF_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU31:ATTREF_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU31:ATTREF_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU31:ATTREF_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU31:ATTREF_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU31:ATTREF_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU31:ATTREF_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU31:ATTREF_SET_SEL")
	field(OUTA, "HU1:CBPM:HU31:ATTREF_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU31:ATTREF_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU31:ATTREF_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU31:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")
	field(OUT,  "HU1:CBPM:HU31:ATTREF_SET_SEL.L PP")
}
# Maintain multiple (up to 10) values of
# a parameter:
# 
# Record holding the parameter $[parm]
# must FLNK -> $[parm]_SEQ
#
# Different values of the parameter 
# $[parm0]..$[parm9] are stored in
# $[parm]_SEL.A .. $[parm]_SEL.J
#
# The actual value of the parameter is
# selected based on the value of a controlling
# PV $[ctrl] using a 'mapping' CALC expression
# $[mapc] to convert the $[ctrl] value into
# the integer range 1..10. 
#
# The selected value of $[parm] is written
# to output link $[outl]
#
# A) When the user writes $[parm] then
#    its value is deposited in the currently
#    selected field of $[parm]_SEL and
#    propagated to $[outl]
#
# B) When the user writes any of $[parm]_SEL.A..J
#    then the value is stored there. If she
#    writes to the currently 'active' field\
#    (as selected by $[ctrl]) then 
#    the $[parm] PV itself is updated and the
#    value is also propagated to $[outl]
#
# C) If the user changes $[ctrl] then the
#    corresponding value $[parm]_SEL.A..J is 
#    propagated to $[outl] and $[parm].
#
# D) At initialization, the value corresponding
#    to the initial setting of $[ctrl] is written
#    to $[outl] and $[parm]
#
# MACROS:
#
# $[parm]  PV holding the parameter
# $[ctrl]  PV that controls the selection of
#          the currently active setting of 
#          $[parm]
# $[outl]  PV where the currently selected 
#          value of $[parm] shall be written-to
#          (if applicable)
# $[prec]  Precision of the $[parm]_SEL variable
#          (should be set to same value as $[parm].PREC)
#
# $[parm0]..$[parm9] initial values of $[parm]
#
# $[mapc]  CALC expression to convert the value
#          of the controlling PV which is available
#          as 'A' to the range 1..10 (or less if
#          less selections are used).
#          E.g., to convert the value of a bo (0/1)
#          you would set mapc to 'A+1' (0..1 -> 1..2)
#
# NOTE:    This sb snippet is loaded/expanded
#          for every parameter under control
#          of $[ctrl]. ALSO, the companion
#          snippet parmCtl.db must be loaded/expanded
#          but only once per controlling PV.
#          

# This record, when scanned (as a result
# of $[parm] being written and processing
# its FLNK to this record] fetches $[parm]
# and deposits the value into the currently
# selected field of the SEL record.
# 
# NOTE: unfortunately, the selection
#       mechanism of the SEQ and SEL
#       records differs: SEQ is 1-based,
#       SEL is 0-based -- now that makes
#       sense, doesn't it?
#
record(seq, "HU1:CBPM:HU31:ATTSPR_SET_SEQ")
{
	field(DESC, "Propagate Parm -> SEL")
	field(DOL1, "HU1:CBPM:HU31:ATTSPR_SET")
	field(DOL2, "HU1:CBPM:HU31:ATTSPR_SET")
	field(DOL3, "HU1:CBPM:HU31:ATTSPR_SET")
	field(DOL4, "HU1:CBPM:HU31:ATTSPR_SET")
	field(DOL5, "HU1:CBPM:HU31:ATTSPR_SET")
	field(DOL6, "HU1:CBPM:HU31:ATTSPR_SET")
	field(DOL7, "HU1:CBPM:HU31:ATTSPR_SET")
	field(DOL8, "HU1:CBPM:HU31:ATTSPR_SET")
	field(DOL9, "HU1:CBPM:HU31:ATTSPR_SET")
	field(DOLA, "HU1:CBPM:HU31:ATTSPR_SET")
	field(LNK1, "HU1:CBPM:HU31:ATTSPR_SET_SEL.A PP")
	field(LNK2, "HU1:CBPM:HU31:ATTSPR_SET_SEL.B PP")
	field(LNK3, "HU1:CBPM:HU31:ATTSPR_SET_SEL.C PP")
	field(LNK4, "HU1:CBPM:HU31:ATTSPR_SET_SEL.D PP")
	field(LNK5, "HU1:CBPM:HU31:ATTSPR_SET_SEL.E PP")
	field(LNK6, "HU1:CBPM:HU31:ATTSPR_SET_SEL.F PP")
	field(LNK7, "HU1:CBPM:HU31:ATTSPR_SET_SEL.G PP")
	field(LNK8, "HU1:CBPM:HU31:ATTSPR_SET_SEL.H PP")
	field(LNK9, "HU1:CBPM:HU31:ATTSPR_SET_SEL.I PP")
	field(LNKA, "HU1:CBPM:HU31:ATTSPR_SET_SEL.J PP")
	field(SELM, "Specified")
	field(SELL, "HU1:CBPM:HU31:ATTSPR_SET_CTRL NPP NMS")
}

# The $[parm]_SEL record holds all possible
# values of $[parm] in the 'A..J' fields.
#
# When processed it updates it's own VAL
# to the currently selected input. Input
# 'L' serves as the (1-based) selector,
# i.e., L==1 selects 'A'->'VAL'.
# 
# When the selected value changes (as a 
# result of SEQ depositing a new value OR
# $[ctrl] changing and updating L) then
# the propagator record attached to the
# FLNK is processed.
#

record(sub, "HU1:CBPM:HU31:ATTSPR_SET_SEL")
{
#	field(INAM, "parmSelSubInit")
	field(SNAM, "parmSelSubProc")
	field(A,    "63")
	field(B,    "63")
	field(C,    "")
	field(D,    "")
	field(E,    "")
	field(F,    "")
	field(G,    "")
	field(H,    "")
	field(I,    "")
	field(J,    "")
	field(PREC, "1")
	field(FLNK, "HU1:CBPM:HU31:ATTSPR_SET_PROP")
  	info(autosaveFields, "A B C D E F G H I J")
}

#
# Finally the dfanout record 
# fetches the currently selected
# value from SEL and propagates it
# to $[outl]. It also updates
# $[parm] itself so that $[parm]
# always reflects the currently
# selected value.
#
record(dfanout,  "HU1:CBPM:HU31:ATTSPR_SET_PROP")
{
	field(OMSL, "closed_loop")
	field(DOL,  "HU1:CBPM:HU31:ATTSPR_SET_SEL")
	field(OUTA, "HU1:CBPM:HU31:ATTSPR_OUT PP NMS")
	field(OUTB, "HU1:CBPM:HU31:ATTSPR_SET PP")
}

# Drive the SEL record when the 'ctrl' PV changes
# Use a CA link to monitor such changes
record(calcout,  "HU1:CBPM:HU31:ATTSPR_SET_CTRL")
{
	field(INPA, "HU1:CBPM:HU31:PARMSEL CP")
	field(CALC, "A+1")
	field(DOPT, "Use CALC")
	field(OOPT, "On Change")