record(ai, "BLD:$(LOCA):$(NMBR):CHARGE") { field(DESC, "Beam Charge") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@CHARGE") field(PREC, "5") field(TSE, "-2") field(EGU, "nC") field(FLNK, "BLD:$(LOCA):$(NMBR):EFCHARGE") field(PRIO, "HIGH") } #record(sub, "BLD:$(LOCA):$(NMBR):CHARGETS") { # field(INAM, "subInit") # field(SNAM, "subProcess") # field(TSEL, "BLD:$(LOCA):$(NMBR):CHARGE.TIME") # field(FLNK, "BLD:$(LOCA):$(NMBR):EFCHARGE") ## field(SCAN, "PASSIVE") #} record(ai, "BLD:$(LOCA):$(NMBR):ENERGY") { field(DESC, "Beam ENERGY") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@ENERGY") field(PREC, "5") field(TSE, "-2") field(EGU, "MeV") field(FLNK, "BLD:$(LOCA):$(NMBR):EFENERGY") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):POS_X") { field(DESC, "Beam Position X") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@POS_X") field(PREC, "5") field(TSE, "-2") field(EGU, "mm") field(FLNK, "BLD:$(LOCA):$(NMBR):EFPOS_X") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):POS_Y") { field(DESC, "Beam Position Y") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@POS_Y") field(PREC, "5") field(TSE, "-2") field(EGU, "mm") field(FLNK, "BLD:$(LOCA):$(NMBR):EFPOS_Y") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):ANG_X") { field(DESC, "Beam Angle X") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@ANG_X") field(PREC, "5") field(TSE, "-2") field(EGU, "mrad") field(FLNK, "BLD:$(LOCA):$(NMBR):EFANG_X") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):ANG_Y") { field(DESC, "Beam Angle Y") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@ANG_Y") field(PREC, "5") field(TSE, "-2") field(EGU, "mrad") field(FLNK, "BLD:$(LOCA):$(NMBR):EFANG_Y") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):BLEN") { field(DESC, "BC2 Charge") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@BC2CHARGE") field(PREC, "3") field(TSE, "-2") field(EGU, "Amps") } record(ai, "BLD:$(LOCA):$(NMBR):BC2CHARGE") { field(DESC, "BC2 Charge") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@BC2CHARGE") field(PREC, "3") field(TSE, "-2") field(EGU, "Amps") field(FLNK, "BLD:$(LOCA):$(NMBR):EFBC2CHARGE") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):BC2ENERGY") { field(DESC, "BC2 Energy") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@BC2ENERGY") field(PREC, "5") field(TSE, "-2") field(EGU, "mm") field(FLNK, "BLD:$(LOCA):$(NMBR):EFBC2ENERGY") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):BC1CHARGE") { field(DESC, "BC1 Charge") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@BC1CHARGE") field(PREC, "3") field(TSE, "-2") field(EGU, "Amps") field(FLNK, "BLD:$(LOCA):$(NMBR):EFBC1CHARGE") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):BC1ENERGY") { field(DESC, "BC2 Energy") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@BC1ENERGY") field(PREC, "5") field(TSE, "-2") field(EGU, "mm") field(FLNK, "BLD:$(LOCA):$(NMBR):EFBC1ENERGY") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):UND_POS_X") { field(DESC, "Beam Position X") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@UND_POS_X") field(PREC, "5") field(TSE, "-2") field(EGU, "mm") field(FLNK, "BLD:$(LOCA):$(NMBR):EFUND_POS_X") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):UND_POS_Y") { field(DESC, "Beam Position Y") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@UND_POS_Y") field(PREC, "5") field(TSE, "-2") field(EGU, "mm") field(FLNK, "BLD:$(LOCA):$(NMBR):EFUND_POS_Y") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):UND_ANG_X") { field(DESC, "Beam Angle X") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@UND_ANG_X") field(PREC, "5") field(TSE, "-2") field(EGU, "mrad") field(FLNK, "BLD:$(LOCA):$(NMBR):EFUND_ANG_X") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):UND_ANG_Y") { field(DESC, "Beam Angle Y") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@UND_ANG_Y") field(PREC, "5") field(TSE, "-2") field(EGU, "mrad") field(FLNK, "BLD:$(LOCA):$(NMBR):EFUND_ANG_Y") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):DMP_CHARGE") { field(DESC, "Dump Charge") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@DMP_CHARGE") field(PREC, "3") field(TSE, "-2") field(EGU, "Nel") field(FLNK, "BLD:$(LOCA):$(NMBR):EFDMP_CHARGE") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):XTCAV_AMP") { field(DESC, "XTCAV Amplitude") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@XTCAV_AMP") field(PREC, "3") field(TSE, "-2") field(EGU, "MV") field(FLNK, "BLD:$(LOCA):$(NMBR):EFXTCAV_AMP") field(PRIO, "HIGH") } # Shantha Condamoor: 7-Jul-2014: Added PHOTONENERGY,LTU450_POS_X and LTU250_POS_X record(ai, "BLD:$(LOCA):$(NMBR):PHOTONENERGY") { field(DESC, "Photon Energy") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@PHOTONENERGY") field(PREC, "5") field(TSE, "-2") field(EGU, "eV") field(FLNK, "BLD:$(LOCA):$(NMBR):EFPHOTONENERGY") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):LTU450_POS_X") { field(DESC, "Beam Position X") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@LTU450_POS_X") field(PREC, "5") field(TSE, "-2") field(EGU, "mm") field(FLNK, "BLD:$(LOCA):$(NMBR):EFLTU450_POS_X") field(PRIO, "HIGH") } record(ai, "BLD:$(LOCA):$(NMBR):LTU250_POS_X") { field(DESC, "Beam Position X") field(SCAN, "$(DIAG_SCAN)") field(DTYP, "BLD_SNDR") field(INP, "@LTU250_POS_X") field(PREC, "5") field(TSE, "-2") field(EGU, "mm") field(FLNK, "BLD:$(LOCA):$(NMBR):EFLTU250_POS_X") field(PRIO, "HIGH") } record(longin, "BLD:$(LOCA):$(NMBR):MCASTSENT") { field(DESC, "MC Messages Sent") field(SCAN, "1 second") field(DTYP, "BusAddress") field(INP, "#C0S2@bld_stat_msg_s,m32") } record( calc, "BLD:$(LOCA):$(NMBR):MCASTRATE" ) { field( SCAN, "1 second" ) field( INPA, "BLD:$(LOCA):$(NMBR):MCASTSENT" ) field( INPB, "BLD:$(LOCA):$(NMBR):MCASTRATE.LA" ) field( INPC, "0.4" ) field( CALC, "VAL*C+(A-B)*(1-C)" ) field( LOLO, "$(LOLO=9)" ) field( LOW, "$(LOW=119)" ) field( HIGH, "$(HIGH=121)" ) field( HIHI, "$(HIHI=361)" ) field( LSV, "$(LSV=MINOR)" ) field( LLSV, "$(LLSV=MAJOR)" ) field( HSV, "$(HSV=MINOR)" ) field( HHSV, "$(HHSV=MAJOR)" ) field( EGU, "Pkt/Sec" ) field( PREC, "1" ) } record(longin, "BLD:$(LOCA):$(NMBR):FCOMLATMIN") { field(DESC, "Min. FCOM Latency") field(EGU, "uS") field(SCAN, "$(STAT_SCAN)") field(DTYP, "BusAddress") field(INP, "#C0S2@bld_stat_min_f,m32") } # just write .PROC record(longout, "BLD:$(LOCA):$(NMBR):FCOMLATMINRST") { field(DESC, "Rst. Min. FCOM Latency") field(SCAN, "Passive") field(DTYP, "BusAddress") field(OUT, "#C0S2@bld_stat_min_f,m32") field(VAL, "-1") field(PINI, "YES") } record(longin, "BLD:$(LOCA):$(NMBR):FCOMLATMAX") { field(DESC, "Max. FCOM Latency") field(EGU, "uS") field(SCAN, "$(STAT_SCAN)") field(DTYP, "BusAddress") field(INP, "#C0S2@bld_stat_max_f,m32") } # just write .PROC record(longout, "BLD:$(LOCA):$(NMBR):FCOMLATMAXRST") { field(DESC, "Rst. Max. FCOM Latency") field(SCAN, "Passive") field(DTYP, "BusAddress") field(OUT, "#C0S2@bld_stat_max_f,m32") field(VAL, "0") field(PINI, "YES") } record(longin, "BLD:$(LOCA):$(NMBR):FCOMLATAVG") { field(DESC, "Avg. FCOM Latency") field(EGU, "uS") field(SCAN, "$(STAT_SCAN)") field(DTYP, "BusAddress") field(INP, "#C0S2@bld_stat_avg_f,m32") } record(longin, "BLD:$(LOCA):$(NMBR):BLDLATMAX") { field(DESC, "Max. BLD Post Latency") field(EGU, "uS") field(SCAN, "$(STAT_SCAN)") field(DTYP, "BusAddress") field(INP, "#C0S2@bld_stat_max_p,m32") } # just write .PROC record(longout, "BLD:$(LOCA):$(NMBR):BLDLATMAXRST") { field(DESC, "Rst. Max. BLD Post Latency") field(SCAN, "Passive") field(DTYP, "BusAddress") field(OUT, "#C0S2@bld_stat_max_p,m32") field(VAL, "0") field(PINI, "YES") } record(longin, "BLD:$(LOCA):$(NMBR):BLDLATAVG") { field(DESC, "Avg. BLD Latency") field(EGU, "uS") field(SCAN, "$(STAT_SCAN)") field(DTYP, "BusAddress") field(INP, "#C0S2@bld_stat_avg_p,m32") } record(bi, "BLD:$(LOCA):$(NMBR):FC_MODE") { field(DESC, "Flag: FCOM sync/async mode") field(DTYP, "BusAddress") field(INP, "#C0S2@bld_fcom_use_s,m32") field(PINI, "YES") field(ZNAM, "ASYNC") field(ONAM, "SYNC") } record(ao, "BLD:$(LOCA):$(NMBR):FC_POLL_DELAY") { field(DESC, "FID to FCOM Sampling Dly") field(SCAN, "Passive") field(DTYP, "BusAddress") field(OUT, "#C0S2@0xdeadbeec,bld_timer_io") field(EGU, "uS") field(LOPR, "100") field(HOPR, "8000") field(DRVL, "100") field(DRVH, "8000") field(VAL, "5000") field(PINI, "YES") } record(ao, "BLD:$(LOCA):$(NMBR):ETAX") { field(DESC, "ETAX used in Photon Energy Calculation") field(SCAN, "Passive") field(DTYP, "BLD_SCALAR") field(OUT, "@ETAX") field(EGU, "mm") field(PREC, "5") info(autosaveFields, "VAL") }