## LLRF RTEMS startup script for LLRF VME crate in RF Hut
## All stations BSA capable

# Where am I?
pwd()

ld("watchdog.obj")
#wdStart(20)

ld("rtems-gdb-stub.obj")
#rtems_gdb_start(0,0)

setenv("FCOMMCGRP", "mc-lcls-fcom",1)

setenv("LANIPBASIC_IP", "172.27.28.50")     # ioc-in20-rf01-fnet
setenv("LANIPBASIC_MASK", "255.255.255.0")
setenv("PACMCGRP", "239.219.0.34")           # ioc-in20-rf01-pacg
setenv("PACCOMMPORT","4849")
setenv("PADMCGRP", "239.219.0.2")           # ioc-in20-rf01-padg


ld("lanIpBasic_mve.obj") #check that it finds this
lanIpSetup(getenv("LANIPBASIC_IP"),getenv("LANIPBASIC_MASK"),0,0) #check def of 1st parm
lanIpDebug=0
padProtoDebug=0

chdir("../..")
ld("bin/RTEMS-beatnik/llrf2RF01App.obj")

#lsmod()

< /boot/lcls/epics/iocCommon/All/Prod/pre_st.cmd
nfsMountsShow()

epicsEnvSet("EPICS_CA_MAX_ARRAY_BYTES","1000000")

#mRouteAdd(getenv("SLC_PROXY_IP"),getenv("SLC_PROXY_GATEWAY_IP"),0xfffffc00,0,0x3)

dbLoadDatabase("dbd/llrf2RF01App.dbd")
llrf2RF01App_registerRecordDeviceDriver(pdbbase)

#drvPadUdpCommSetup("172.27.206.255:0000")
drvPadUdpCommSetup(getenv("PADMCGRP"), &cbDrvPadUdpCommLLRF)
drvPadUdpCommTimeout=1000

fcomInit(fcomUtilGethostbyname(getenv("FCOMMCGRP"),0),1000)

# hack around the EPICS memory tester
free(malloc(1024*1024*32))

dbLoadTemplate("db/llrfIN20.l0a_template")
dbLoadTemplate("db/llrfIN20.l0b_template")
dbLoadTemplate("db/llrfIN20.lsr_template") 
dbLoadTemplate("db/llrfIN20.ph1_template")
dbLoadTemplate("db/llrfIN20.clk_template")
dbLoadTemplate("db/llrfIN20.ref_template")
dbLoadTemplate("db/llrfIN20.fdbk_template")
dbLoadTemplate("db/llrfIN20.gnt_template")
dbLoadTemplate("db/llrfIN20.gnt_phas_template")
dbLoadTemplate("db/llrfIN20.tc0_template")
dbLoadTemplate("db/llrfIN20.kly_template")
dbLoadTemplate("db/llrfIN20.l2ref_template")
dbLoadTemplate("db/llrfIN20.gbl_template")

dbLoadTemplate("db/llrfLI21.ph2_template")
dbLoadTemplate("db/llrfLI21.l1x_template")
dbLoadTemplate("db/llrfLI21.kly_template")
dbLoadTemplate("db/llrfLI21.gbl_template")

dbLoadTemplate("db/llrfIN20.pau_template")

dbLoadRecords("db/IOC-IN20-RF01evr.db") # has all three EVRs' recs
dbLoadRecords("db/IOC-IN20-RF01trig.db") # has all three EVRs' recs
dbLoadRecords("db/IOC-IN20-RF01pattern.db")
dbLoadRecords("db/IOC-IN20-RF01bsa.db")
dbLoadRecords("db/IOC-LI21-RF01bsa.db")

dbLoadRecords("db/iocAdmin.db","IOC=IOC:IN20:RF01")
dbLoadRecords("db/iocRelease.db", "IOC=IOC:IN20:RF01")

dbLoadRecords("db/IOC-IN20-RF01access.db")
dbLoadRecords("db/IOC-LI21-RF01access.db")

# bspExtMemProbe only durint init. clear this to avoid the lecture.
bspExtVerbosity=0

# From Till Straumann (for RTEMS 4.9.1 upgrade):
# This should set the VME chip into a mode where it
# surrenders the VME bus after every transaction.
# This means that the master has to rearbitrate for the bus for every cycle
# (which slows things down).
#
# The faster setting I had enabled would let the master hold on to the bus
# until some other master requests it.
*(long*)(vmeTsi148RegBase + 0x234) &= ~ 0x18


# hardware initialization
drvMrfErFlag=0
# ErConfigure(slot #, address, irq vec, irq level, EVR type(0=VME,1=PMC))
ErConfigure(0,0x300000,0x60,4,0)
ErConfigure(1,0x400000,0x62,4,0)
ErConfigure(2,0x500000,0x64,4,0)

devAiLlrfFlag=0
devAoLlrfFlag=0
devWaveformLlrfFlag=0
drvLlrfPC1Flag=0
drvLlrfPC2Flag=0
devWaveformLlrfDebug=0


createPau("pau0", 2, "Active PAU")
createPau("pau1", 2, "PAU for Laser")
#createPau("pau2", 2, "Spare PAU2")
#createPau("pau3", 2, "Spare PAU3")

createMux("pau1", "LASR:IN20:1:LSR_PDES2856", "lsrPhase2856Push", "lsrPhase2856Pull", "Laser 2856MHz Phase")
createMux("pau1", "LASR:IN20:1:LSR_PDES119",  "lsrPhase119Push",  "lsrPhase119Pull",  "Laser 119MHz Phase")
createMux("pau1", "LASR:IN20:1:LSR_ADES",     "lsrAmplPush",      "lsrAmplPull",      "Laser Amplitude")
makeAssociation("LASR:IN20:1:LSR_PDES2856", "LASR:IN20:1:LSR_ADES")
makeAssociation("LASR:IN20:1:LSR_PDES119",  "LASR:IN20:1:LSR_ADES")

createMux("pau0", "GUN:IN20:1:GN1_PDES", "gunPhasePush", "gunPhasePull", "GUN Phase")
createMux("pau0", "GUN:IN20:1:GN1_ADES", "gunAmplPush",  "gunAmplPull",  "GUN Amplitude")
makeAssociation("GUN:IN20:1:GN1_PDES", "GUN:IN20:1:GN1_ADES")

createMux("pau0", "ACCL:IN20:300:L0A_PDES", "l0aPhasePush", "l0aPhasePull", "L0A Phase")
createMux("pau0", "ACCL:IN20:300:L0A_ADES", "l0aAmplPush",  "l0aAmplPull",  "L0A Amplitude")
makeAssociation("ACCL:IN20:300:L0A_PDES", "ACCL:IN20:300:L0A_ADES")

createMux("pau0", "ACCL:IN20:400:L0B_PDES", "l0bPhasePush", "l0bPhasePull", "L0B Phase")
createMux("pau0", "ACCL:IN20:400:L0B_ADES", "l0bAmplPush", "l0bAmplPull", "L0B Amplitude")
makeAssociation("ACCL:IN20:400:L0B_PDES", "ACCL:IN20:400:L0B_ADES")

createMux("pau0", "TCAV:IN20:490:TC0_PDES", "tc0PhasePush", "tc0PhasePull", "TCAV0 Phase")
createMux("pau0", "TCAV:IN20:490:TC0_ADES", "tc0AmplPush",  "tc0AmplPull",  "TCAV0 Amplitude")
makeAssociation("TCAV:IN20:490:TC0_PDES", "TCAV:IN20:490:TC0_ADES")

createMux("pau0", "ACCL:LI21:1:L1S_PDES", "l1sPhasePush", "l1sPhasePull", "L1S Phase")
createMux("pau0", "ACCL:LI21:1:L1S_ADES", "l1sAmplPush",  "l1sAmplPull",  "L1S Amplitude")
makeAssociation("ACCL:LI21:1:L1S_PDES", "ACCL:LI21:1:L1S_ADES")

createMux("pau0", "ACCL:LI21:180:L1X_PDES", "l1xPhasePush", "l1xPhasePull", "L1X Phase")
createMux("pau0", "ACCL:LI21:180:L1X_ADES", "l1xAmplPush",  "l1xAmplPull",  "L1X Amplitude")
makeAssociation("ACCL:LI21:180:L1X_PDES", "ACCL:LI21:180:L1X_ADES")

createMux("pau0", "LLRF:IN20:RH:L2_MUX_PSET", "l2refPhasePush", "l2refPhasePull", "L2 ref Phase")
createMux("pau0", "LLRF:IN20:RH:L2_MUX_ASET", "l2refAmplPush",  "l2refAmplPull",  "L2 ref Amplitude")
makeAssociation("LLRF:IN20:RH:L2_MUX_PSET", "LLRF:IN20:RH:L2_MUX_ASET")


# Works if /data mountpoint maps to $LCDATA/epics/ioc/data/LLRF
dbRestore("/data/IOC-IN20-RF01trig.sav")
dbRestore("/data/IOC-IN20-RF01.sav")
dbRestore("/data/IOC-IN20-RF01pau.sav")

iocInit()


seq(&pacTrace, "STATION=LSR, PV_I_MON=LASR:IN20:1:LSR_I_MONT,   PV_Q_MON=LASR:IN20:1:LSR_Q_MONT")
seq(&pacTrace, "STATION=GN1, PV_I_MON=GUN:IN20:1:GUN_I_MONT,    PV_Q_MON=GUN:IN20:1:GUN_Q_MONT")
seq(&pacTrace, "STATION=L0A, PV_I_MON=ACCL:IN20:300:L0A_I_MONT, PV_Q_MON=ACCL:IN20:300:L0A_Q_MONT")
seq(&pacTrace, "STATION=L0B, PV_I_MON=ACCL:IN20:400:L0B_I_MONT, PV_Q_MON=ACCL:IN20:400:L0B_Q_MONT")
seq(&pacTrace, "STATION=TC0, PV_I_MON=TCAV:IN20:490:TC0_I_MONT, PV_Q_MON=TCAV:IN20:490:TC0_Q_MONT")
seq(&pacTrace, "STATION=L1S, PV_I_MON=ACCL:LI21:1:L1S_I_MONT,   PV_Q_MON=ACCL:LI21:1:L1S_Q_MONT")
seq(&pacTrace, "STATION=L1X, PV_I_MON=ACCL:LI21:180:L1X_I_MONT, PV_Q_MON=ACCL:LI21:180:L1X_Q_MONT")


devAiLlrfFlag=0
dbSendFlag=0
dbCtlFlag=0
dbRecvFlag=0
msgHdlrFlag=0

## Initial processing for Laser Station

# 5/5/8 new (next 3 lines)
dbpf("LASR:IN20:1:LSR_SEND","1")
dbpf("LASR:IN20:1:LSR_PDES119.PROC","1")
dbpf("LASR:IN20:1:LSR_PDES2856.PROC","1")
dbpf("LASR:IN20:1:LSR_PDES2805.PROC","1")

dbpf("LASR:IN20:1:LSR_ADES.PROC","1")
dbpf("LASR:IN20:1:LSR_P_FB_PND","0")
dbpf("LASR:IN20:1:LSR_0_POC.PROC","1")
dbpf("LASR:IN20:1:LSR_1_POC.PROC","1")
dbpf("LASR:IN20:1:LSR_2_POC.PROC","1")
dbpf("LASR:IN20:1:LSR_3_POC.PROC","1")
dbpf("LASR:IN20:1:LSR_0_AVC.PROC","1")
dbpf("LASR:IN20:1:LSR_1_AVC.PROC","1")
dbpf("LASR:IN20:1:LSR_2_AVC.PROC","1")
dbpf("LASR:IN20:1:LSR_3_AVC.PROC","1")
dbpf("LASR:IN20:1:LSR_0_APC.PROC","1")
dbpf("LASR:IN20:1:LSR_1_APC.PROC","1")
dbpf("LASR:IN20:1:LSR_2_APC.PROC","1")
dbpf("LASR:IN20:1:LSR_3_APC.PROC","1")
dbpf("LASR:IN20:1:LSR_PSMOOTH.PROC","1")
dbpf("LASR:IN20:1:LSR_PCORMAX.PROC","1")
dbpf("LASR:IN20:1:LSR_PCORMIN.PROC","1")
dbpf("LASR:IN20:1:LSR_ISCL.PROC","1") # new 10/20/8
dbpf("LASR:IN20:1:LSR_QSCL.PROC","1") # new 10/20/8
dbpf("LASR:IN20:1:LSR_ISET.OMSL","closed_loop") # new 10/21/8
dbpf("LASR:IN20:1:LSR_ISET.DOL","LASR:IN20:1:LSR_IGET") #new 10/21/8
dbpf("LASR:IN20:1:LSR_QSET.OMSL","closed_loop") #new 10/21/8
dbpf("LASR:IN20:1:LSR_QSET.DOL","LASR:IN20:1:LSR_QGET") #new 10/21/8
dbpf("LASR:IN20:1:LSR_MON_IADJ.OMSL","closed_loop") # new 10/21/8
dbpf("LASR:IN20:1:LSR_MON_IADJ.DOL","LASR:IN20:1:LSR_I_ADJUST CP MS") #new 10/21/8
dbpf("LASR:IN20:1:LSR_MON_QADJ.OMSL","closed_loop") # new 10/21/8
dbpf("LASR:IN20:1:LSR_MON_QADJ.DOL","LASR:IN20:1:LSR_Q_ADJUST CP MS") #new 10/21/8
dbpf("LASR:IN20:1:LSR_PWR_THLD.PROC","1") #new 10/17/8

# What I want to happen is:
# 1) restore value to LASR:IN20:1:LSR_ZERO_MON from .sav file (expect that SEVR/STAT have errors
# 2) set LASR:IN20:1:LSR_ZEROING's OMSL so that it can get its DOL from LASR:IN20:1:LSR_ZERO_MON. Now LASR:IN20:1:LSR_ZEROING.VAL s/b LASR:IN20:1:LSR_ZERO_MON
# 3) process LASR:IN20:1:LSR_ZEROING so that it "sets" value in struct to LASR:IN20:1:LSR_ZERO_MON's saved/restored value
dbpf("LASR:IN20:1:LSR_ZEROING.OMSL","closed_loop")
dbpf("LASR:IN20:1:LSR_ZEROING.DOL","LASR:IN20:1:LSR_ZERO_MON")
dbpf("LASR:IN20:1:LSR_ZEROING.PROC","1") # gets VAL of _ZERO_MON (with UDF/INV)
dbpf("LASR:IN20:1:LSR_SOURCE.PROC","1") # to fix UDF/INV (and FLNK _PDES)
dbpf("LASR:IN20:1:LSR_ZERO_MON.SCAN","2 second") # to fix UDF/INV (and FLNK _PDES) and keep it up to date 

## Initial processing for Reference Station
# 6/22/8. Yes. We DO want this sending to PAC so cmt this out... 
#dbpf("LLRF:IN20:RH:REF_2_SEND","1")
#5/8/8: uncomment next two lines
dbpf("LLRF:IN20:RH:REF_2_ISET.PROC","1")
dbpf("LLRF:IN20:RH:REF_2_QSET.PROC","1")

# 5/5/8 new. needed for ops as well. at least until it's known that calcout triggering
# PSET processing is the way to go. If it's good, add OOPT to llrfcalcout.db and# fix ALL templates that include it
dbpf("LLRF:IN20:RH:REF_2_CONVERGE.OOPT","When Non-zero")

#6/10/8: new. to fix UDF
dbpf("LLRF:IN20:RH:REF_0_POC.PROC","1")
dbpf("LLRF:IN20:RH:REF_1_POC.PROC","1")
dbpf("LLRF:IN20:RH:REF_2_POC.PROC","1")
dbpf("LLRF:IN20:RH:REF_3_POC.PROC","1")
#7/31/8: new. to fix UDF - yeah so there are lots more, too.
#        I only do a fraction of them and it's a bad method.
#        Better would be to use PINI=YES, but then you can't
#        control the order of processing, and, in some cases,
#        this matters  
dbpf("LLRF:IN20:RH:REF_0_AVC.PROC","1")
dbpf("LLRF:IN20:RH:REF_1_AVC.PROC","1")
dbpf("LLRF:IN20:RH:REF_2_AVC.PROC","1")
dbpf("LLRF:IN20:RH:REF_3_AVC.PROC","1")
dbpf("LLRF:IN20:RH:REF_0_APC.PROC","1")
dbpf("LLRF:IN20:RH:REF_1_APC.PROC","1")
dbpf("LLRF:IN20:RH:REF_2_APC.PROC","1")
dbpf("LLRF:IN20:RH:REF_3_APC.PROC","1")
dbpf("LLRF:IN20:RH:REF_0_PDES.PROC","1")
dbpf("LLRF:IN20:RH:REF_2_PDES.PROC","1")
dbpf("LLRF:IN20:RH:REF_3_PDES.PROC","1")
dbpf("LLRF:IN20:RH:REF_0_ADES.PROC","1")
dbpf("LLRF:IN20:RH:REF_2_ADES.PROC","1")
dbpf("LLRF:IN20:RH:REF_3_ADES.PROC","1")
dbpf("LLRF:IN20:RH:REF_0_ISCL.PROC","1")
dbpf("LLRF:IN20:RH:REF_2_ISCL.PROC","1")
dbpf("LLRF:IN20:RH:REF_3_ISCL.PROC","1")
dbpf("LLRF:IN20:RH:REF_0_QSCL.PROC","1")
dbpf("LLRF:IN20:RH:REF_2_QSCL.PROC","1")
dbpf("LLRF:IN20:RH:REF_3_QSCL.PROC","1")

dbpf("LLRF:IN20:RH:REF_0_ISET.PROC","1")
dbpf("LLRF:IN20:RH:REF_0_QSET.PROC","1")
dbpf("LLRF:IN20:RH:REF_3_ISET.PROC","1")
dbpf("LLRF:IN20:RH:REF_3_QSET.PROC","1")
dbpf("LLRF:IN20:RH:CLK_ISET.PROC","1")
dbpf("LLRF:IN20:RH:CLK_QSET.PROC","1")

# explicitly enable (intentionally don't want to restore what was before boot)
dbpf("LLRF:IN20:RH:CLK_ISCL.PROC","1")
dbpf("LLRF:IN20:RH:CLK_QSCL.PROC","1")
dbpf("LLRF:IN20:RH:REF_0_SEND","0")
dbpf("LLRF:IN20:RH:REF_3_SEND","0")
dbpf("LLRF:IN20:RH:CLK_SEND","0")

# explicitly disable (intentionally don't want to restore what was before boot)
# 8/4/8: This needs to start out SENDING. 
dbpf("LLRF:IN20:RH:L2_SEND","0")
# 5/14/8 next five lines are new
dbpf("LLRF:IN20:RH:L2_PDES.PROC","1")
dbpf("LLRF:IN20:RH:L2_POC.PROC","1")
dbpf("LLRF:IN20:RH:L2_ADES.PROC","1")
dbpf("LLRF:IN20:RH:L2_ISET.PROC","1")
dbpf("LLRF:IN20:RH:L2_QSET.PROC","1")

dbpf("LLRF:IN20:RH:L2_ISCL.PROC", "1")
dbpf("LLRF:IN20:RH:L2_QSCL.PROC", "1")

## Initial processing for RF Gun Cell Station

dbpf("GUN:IN20:1:GN1_PHAS_FB","0") # moved from st-prod.cmd
dbpf("GUN:IN20:1:GN1_AMPL_FB","0")
dbpf("GUN:IN20:1:GN1_0_PWT.PROC","1")
dbpf("GUN:IN20:1:GN1_1_PWT.PROC","1")
dbpf("GUN:IN20:1:GN1_2_PWT.PROC","1")
dbpf("GUN:IN20:1:GN1_3_PWT.PROC","1")
dbpf("GUN:IN20:1:GN1_0_AWT.PROC","1")
dbpf("GUN:IN20:1:GN1_1_AWT.PROC","1")
dbpf("GUN:IN20:1:GN1_2_AWT.PROC","1")
dbpf("GUN:IN20:1:GN1_3_AWT.PROC","1")
dbpf("GUN:IN20:1:GN1_TOT_PWT.PROC","1")
dbpf("GUN:IN20:1:GN1_TOT_AWT.PROC","1")
dbpf("GUN:IN20:1:GN1_0_POC.PROC","1")
dbpf("GUN:IN20:1:GN1_1_POC.PROC","1")
dbpf("GUN:IN20:1:GN1_2_POC.PROC","1")
dbpf("GUN:IN20:1:GN1_3_POC.PROC","1")
dbpf("GUN:IN20:1:GN1_0_APC.PROC","1")
dbpf("GUN:IN20:1:GN1_1_APC.PROC","1")
dbpf("GUN:IN20:1:GN1_2_APC.PROC","1")
dbpf("GUN:IN20:1:GN1_3_APC.PROC","1")
dbpf("GUN:IN20:1:GN1_0_AVC.PROC","1")
dbpf("GUN:IN20:1:GN1_1_AVC.PROC","1")
dbpf("GUN:IN20:1:GN1_2_AVC.PROC","1")
dbpf("GUN:IN20:1:GN1_3_AVC.PROC","1")
dbpf("GUN:IN20:1:GN1_PSMOOTH.PROC","1")
dbpf("GUN:IN20:1:GN1_ASMOOTH.PROC","1")
dbpf("GUN:IN20:1:GN1_PCORMIN.PROC","1")
dbpf("GUN:IN20:1:GN1_PCORMAX.PROC","1")
dbpf("GUN:IN20:1:GN1_ACORMIN.PROC","1")
dbpf("GUN:IN20:1:GN1_ACORMAX.PROC","1")
# 3/19/2007 new. need to get set for other stations still!!!
dbpf("GUN:IN20:1:GN1_PSETMIN.PROC","1")
dbpf("GUN:IN20:1:GN1_PSETMAX.PROC","1")
dbpf("GUN:IN20:1:GN1_ASETMIN.PROC","1")
dbpf("GUN:IN20:1:GN1_ASETMAX.PROC","1")
dbpf("GUN:IN20:1:GN1_QSCALE.PROC","1")
dbpf("GUN:IN20:1:GN1_ISCALE.PROC","1")
# Default is for values to be sent. Convention is non-intuitive so that
# DISV=1 can be used. Val of this bo record compared to DISV and if they
# match, then sending to PAC is disabled. Therefore enabled = 0.
dbpf("GUN:IN20:1:GN1_SEND","1")
dbpf("GUN:IN20:1:GN1_PHAS_FB.PROC","1")
dbpf("GUN:IN20:1:GN1_AMPL_FB.PROC","1")
dbpf("GUN:IN20:1:GN1_PRV_ASET.PROC","1") # don't let it go below 100
dbpf("GUN:IN20:1:GN1_PDES.PROC","1")
dbpf("GUN:IN20:1:GN1_ADES.PROC","1")
# 5/14/8 new
dbpf("GUN:IN20:1:GN1_PWR_THLD.PROC","1")
dbpf("GUN:IN20:1:GN2_PID_SUM.OMSL", "closed_loop")
dbpf("GUN:IN20:1:GN2_PID_SUM.HOPR", "10")
dbpf("GUN:IN20:1:GN2_PID_SUM.LOPR", "-10")
dbpf("GUN:IN20:1:GN2_PID_ENABLE", "Auto")
dbpf("GUN:IN20:1:GN2_PID_CTL", "ON")
dbpf("GUN:IN20:1:GN2_TEMP_PID.SCAN", "1 second") # do this last, after PID enable is Manual and control is OFF
dbpf("GUN:IN20:1:GN2_TEMP_SP.PROC","1")

## Initial settings for S-Band GN2 Station's RF Phase loop before save/restored

dbpf("GUN:IN20:1:GN2_KP2", "1.0")
dbpf("GUN:IN20:1:GN2_KI2", "0.03")
dbpf("GUN:IN20:1:GN2_PHAS_SP", "0.") # I have no idea what to set this to
dbpf("GUN:IN20:1:GN2_PID2_SUM.OMSL", "closed_loop")
dbpf("GUN:IN20:1:GN2_PID2_SUM.HOPR", "10")
dbpf("GUN:IN20:1:GN2_PID2_SUM.LOPR", "-10")
dbpf("GUN:IN20:1:GN2_PID2ENABLE", "Manual")
dbpf("GUN:IN20:1:GN2_PID2_CTL", "OFF")
dbpf("GUN:IN20:1:GN2_PHAS_PID.SCAN", "1 second") # do this last, after PID enable is Manual and control is OFF
dbpf("GUN:IN20:1:GN2_PHAS_SP.PROC","1")

## Initial processing for S-Band L0-A Station

dbpf("ACCL:IN20:300:L0A_PHAS_FB","0") # moved from st-prod.cmd
dbpf("ACCL:IN20:300:L0A_AMPL_FB","0")
dbpf("ACCL:IN20:300:L0A_0_PWT.PROC","1")
dbpf("ACCL:IN20:300:L0A_1_PWT.PROC","1")
dbpf("ACCL:IN20:300:L0A_0_AWT.PROC","1")
dbpf("ACCL:IN20:300:L0A_1_AWT.PROC","1")
dbpf("ACCL:IN20:300:L0A_TOT_PWT.PROC","1")
dbpf("ACCL:IN20:300:L0A_TOT_AWT.PROC","1")
dbpf("ACCL:IN20:300:L0A_0_POC.PROC","1")
dbpf("ACCL:IN20:300:L0A_1_POC.PROC","1")
dbpf("ACCL:IN20:300:L0A_0_APC.PROC","1")
dbpf("ACCL:IN20:300:L0A_1_APC.PROC","1")
dbpf("ACCL:IN20:300:L0A_0_AVC.PROC","1")
dbpf("ACCL:IN20:300:L0A_1_AVC.PROC","1")
dbpf("ACCL:IN20:300:L0A_PSMOOTH.PROC","1")
dbpf("ACCL:IN20:300:L0A_ASMOOTH.PROC","1")
dbpf("ACCL:IN20:300:L0A_PCORMIN.PROC","1")
dbpf("ACCL:IN20:300:L0A_PCORMAX.PROC","1")
dbpf("ACCL:IN20:300:L0A_ACORMIN.PROC","1")
dbpf("ACCL:IN20:300:L0A_ACORMAX.PROC","1")
# 3/19/2007 new. need to get set for other stations still!!!
dbpf("ACCL:IN20:300:L0A_PSETMIN.PROC","1")
dbpf("ACCL:IN20:300:L0A_PSETMAX.PROC","1")
dbpf("ACCL:IN20:300:L0A_ASETMIN.PROC","1")
dbpf("ACCL:IN20:300:L0A_ASETMAX.PROC","1")
dbpf("ACCL:IN20:300:L0A_QSCALE.PROC","1")
dbpf("ACCL:IN20:300:L0A_ISCALE.PROC","1")
# Default is for values to be sent. Convention is non-intuitive so that
# DISV=1 can be used. Val of this bo record compared to DISV and if they
# match, then sending to PAC is disabled. Therefore enabled = 0.
dbpf("ACCL:IN20:300:L0A_SEND","1")
dbpf("ACCL:IN20:300:L0A_PHAS_FB.PROC","1")
dbpf("ACCL:IN20:300:L0A_AMPL_FB.PROC","1")
dbpf("ACCL:IN20:300:L0A_PRV_ASET.PROC","1") # don't let it go below 100
dbpf("ACCL:IN20:300:L0A_PDES.PROC","1")
dbpf("ACCL:IN20:300:L0A_ADES.PROC","1")
# 5/14/8 new
dbpf("ACCL:IN20:300:L0A_PWR_THLD.PROC","1")

## Initial processing for S-Band L0-B Station

dbpf("ACCL:IN20:400:L0B_PHAS_FB","0") # moved from st-prod.cmd
dbpf("ACCL:IN20:400:L0B_AMPL_FB","0")
dbpf("ACCL:IN20:400:L0B_2_PWT.PROC","1")
dbpf("ACCL:IN20:400:L0B_3_PWT.PROC","1")
dbpf("ACCL:IN20:400:L0B_2_AWT.PROC","1")
dbpf("ACCL:IN20:400:L0B_3_AWT.PROC","1")
dbpf("ACCL:IN20:400:L0B_TOT_PWT.PROC","1")
dbpf("ACCL:IN20:400:L0B_TOT_AWT.PROC","1")
dbpf("ACCL:IN20:400:L0B_2_POC.PROC","1")
dbpf("ACCL:IN20:400:L0B_3_POC.PROC","1")
dbpf("ACCL:IN20:400:L0B_2_APC.PROC","1")
dbpf("ACCL:IN20:400:L0B_3_APC.PROC","1")
dbpf("ACCL:IN20:400:L0B_2_AVC.PROC","1")
dbpf("ACCL:IN20:400:L0B_3_AVC.PROC","1")
dbpf("ACCL:IN20:400:L0B_PSMOOTH.PROC","1")
dbpf("ACCL:IN20:400:L0B_ASMOOTH.PROC","1")
dbpf("ACCL:IN20:400:L0B_PCORMIN.PROC","1")
dbpf("ACCL:IN20:400:L0B_PCORMAX.PROC","1")
dbpf("ACCL:IN20:400:L0B_ACORMIN.PROC","1")
dbpf("ACCL:IN20:400:L0B_ACORMAX.PROC","1")
dbpf("ACCL:IN20:400:L0B_PSETMIN.PROC","1")
dbpf("ACCL:IN20:400:L0B_PSETMAX.PROC","1")
dbpf("ACCL:IN20:400:L0B_ASETMIN.PROC","1")
dbpf("ACCL:IN20:400:L0B_ASETMAX.PROC","1")
dbpf("ACCL:IN20:400:L0B_QSCALE.PROC","1")
dbpf("ACCL:IN20:400:L0B_ISCALE.PROC","1")
# Default is for values to be sent. Convention is non-intuitive so that
# DISV=1 can be used. Val of this bo record compared to DISV and if they
# match, then sending to PAC is disabled. Therefore enabled = 0.
dbpf("ACCL:IN20:400:L0B_SEND","1")
dbpf("ACCL:IN20:400:L0B_PHAS_FB.PROC","1")
dbpf("ACCL:IN20:400:L0B_AMPL_FB.PROC","1")
dbpf("ACCL:IN20:400:L0B_PRV_ASET.PROC","1") # don't let it go below 100
dbpf("ACCL:IN20:400:L0B_PDES.PROC","1")
dbpf("ACCL:IN20:400:L0B_ADES.PROC","1")
# 5/14/8 new
dbpf("ACCL:IN20:400:L0B_PWR_THLD.PROC","1")

## Initial processing for S-Band TCav Station

dbpf("TCAV:IN20:490:TC0_PHAS_FB","0") # NEW 5/11/7
dbpf("TCAV:IN20:490:TC0_AMPL_FB","0") # NEW 5/11/7
dbpf("TCAV:IN20:490:TC0_0_PWT.PROC","1")
dbpf("TCAV:IN20:490:TC0_1_PWT.PROC","1")
dbpf("TCAV:IN20:490:TC0_0_AWT.PROC","1")
dbpf("TCAV:IN20:490:TC0_1_AWT.PROC","1")
dbpf("TCAV:IN20:490:TC0_TOT_PWT.PROC","1")
dbpf("TCAV:IN20:490:TC0_TOT_AWT.PROC","1")
dbpf("TCAV:IN20:490:TC0_0_POC.PROC","1")
dbpf("TCAV:IN20:490:TC0_1_POC.PROC","1")
dbpf("TCAV:IN20:490:TC0_2_POC.PROC","1")
dbpf("TCAV:IN20:490:TC0_3_POC.PROC","1")
dbpf("TCAV:IN20:490:TC0_0_APC.PROC","1")
dbpf("TCAV:IN20:490:TC0_1_APC.PROC","1")
dbpf("TCAV:IN20:490:TC0_2_APC.PROC","1")
dbpf("TCAV:IN20:490:TC0_3_APC.PROC","1")
dbpf("TCAV:IN20:490:TC0_0_AVC.PROC","1")
dbpf("TCAV:IN20:490:TC0_1_AVC.PROC","1")
dbpf("TCAV:IN20:490:TC0_2_AVC.PROC","1")
dbpf("TCAV:IN20:490:TC0_3_AVC.PROC","1")
dbpf("TCAV:IN20:490:TC0_PSMOOTH.PROC","1")
dbpf("TCAV:IN20:490:TC0_ASMOOTH.PROC","1")
dbpf("TCAV:IN20:490:TC0_PCORMIN.PROC","1")
dbpf("TCAV:IN20:490:TC0_PCORMAX.PROC","1")
dbpf("TCAV:IN20:490:TC0_ACORMIN.PROC","1")
dbpf("TCAV:IN20:490:TC0_ACORMAX.PROC","1")
dbpf("TCAV:IN20:490:TC0_PSETMIN.PROC","1")
dbpf("TCAV:IN20:490:TC0_PSETMAX.PROC","1")
dbpf("TCAV:IN20:490:TC0_ASETMIN.PROC","1")
dbpf("TCAV:IN20:490:TC0_ASETMAX.PROC","1")
dbpf("TCAV:IN20:490:TC0_QSCALE.PROC","1")
dbpf("TCAV:IN20:490:TC0_ISCALE.PROC","1")
# Default is for values to be sent. Convention is non-intuitive so that
# DISV=1 can be used. Val of this bo record compared to DISV and if they
# match, then sending to PAC is disabled. Therefore enabled = 0.
dbpf("TCAV:IN20:490:TC0_SEND","1")
dbpf("TCAV:IN20:490:TC0_PHAS_FB.PROC","1")
dbpf("TCAV:IN20:490:TC0_AMPL_FB.PROC","1")
dbpf("TCAV:IN20:490:TC0_PRV_ASET.PROC","1") # don't let it go below 100
dbpf("TCAV:IN20:490:TC0_PDES.PROC","1")
dbpf("TCAV:IN20:490:TC0_ADES.PROC","1")
# 5/14/8 new
dbpf("TCAV:IN20:490:TC0_PWR_THLD.PROC","1")

## Initial processing for S-Band L1-S Station

dbpf("ACCL:LI21:1:L1S_PHAS_FB","0") # moved from st-prod.cmd 5/29/7
dbpf("ACCL:LI21:1:L1S_AMPL_FB","0")
dbpf("ACCL:LI21:1:L1S_0_PWT.PROC","1")
dbpf("ACCL:LI21:1:L1S_1_PWT.PROC","1")
dbpf("ACCL:LI21:1:L1S_2_PWT.PROC","1")
dbpf("ACCL:LI21:1:L1S_3_PWT.PROC","1")
dbpf("ACCL:LI21:1:L1S_0_AWT.PROC","1")
dbpf("ACCL:LI21:1:L1S_1_AWT.PROC","1")
dbpf("ACCL:LI21:1:L1S_2_AWT.PROC","1")
dbpf("ACCL:LI21:1:L1S_3_AWT.PROC","1")
dbpf("ACCL:LI21:1:L1S_TOT_PWT.PROC","1")
dbpf("ACCL:LI21:1:L1S_TOT_AWT.PROC","1")
dbpf("ACCL:LI21:1:L1S_0_POC.PROC","1")
dbpf("ACCL:LI21:1:L1S_1_POC.PROC","1")
dbpf("ACCL:LI21:1:L1S_2_POC.PROC","1")
dbpf("ACCL:LI21:1:L1S_3_POC.PROC","1")
dbpf("ACCL:LI21:1:L1S_0_APC.PROC","1")
dbpf("ACCL:LI21:1:L1S_1_APC.PROC","1")
dbpf("ACCL:LI21:1:L1S_2_APC.PROC","1")
dbpf("ACCL:LI21:1:L1S_3_APC.PROC","1")
dbpf("ACCL:LI21:1:L1S_0_AVC.PROC","1")
dbpf("ACCL:LI21:1:L1S_1_AVC.PROC","1")
dbpf("ACCL:LI21:1:L1S_2_AVC.PROC","1")
dbpf("ACCL:LI21:1:L1S_3_AVC.PROC","1")
dbpf("ACCL:LI21:1:L1S_PSMOOTH.PROC","1")
dbpf("ACCL:LI21:1:L1S_ASMOOTH.PROC","1")
dbpf("ACCL:LI21:1:L1S_PCORMIN.PROC","1")
dbpf("ACCL:LI21:1:L1S_PCORMAX.PROC","1")
dbpf("ACCL:LI21:1:L1S_ACORMIN.PROC","1")
dbpf("ACCL:LI21:1:L1S_ACORMAX.PROC","1")
dbpf("ACCL:LI21:1:L1S_PSETMIN.PROC","1")
dbpf("ACCL:LI21:1:L1S_PSETMAX.PROC","1")
dbpf("ACCL:LI21:1:L1S_ASETMIN.PROC","1")
dbpf("ACCL:LI21:1:L1S_ASETMAX.PROC","1")
dbpf("ACCL:LI21:1:L1S_QSCALE.PROC","1")
dbpf("ACCL:LI21:1:L1S_ISCALE.PROC","1")
# Default is for values to be sent. Convention is non-intuitive so that
# DISV=1 can be used. Val of this bo record compared to DISV and if they
# match, then sending to PAC is disabled. Therefore enabled = 0.
dbpf("ACCL:LI21:1:L1S_SEND","1")
dbpf("ACCL:LI21:1:L1S_PHAS_FB.PROC","1")
dbpf("ACCL:LI21:1:L1S_AMPL_FB.PROC","1")
dbpf("ACCL:LI21:1:L1S_PRV_ASET.PROC","1") # don't let it go below 100
dbpf("ACCL:LI21:1:L1S_PDES.PROC","1")
dbpf("ACCL:LI21:1:L1S_ADES.PROC","1")
dbpf("ACCL:LI21:1:L1S_PWR_THLD.PROC","1")

## Initial processing for X-Band L1-X Station
## Notes:
## - channels 2 and 3 are not part of feedback, so they have no weighting factors
## - channel 2 is a simple average (voltage), so it has no offset or scale factors

dbpf("ACCL:LI21:180:L1X_PHAS_FB","0")
dbpf("ACCL:LI21:180:L1X_AMPL_FB","0")
# 7/16/8 add these 
dbpf("ACCL:LI21:180:L1X_0_IQWT.PROC","1")
dbpf("ACCL:LI21:180:L1X_1_IQWT.PROC","1")
dbpf("ACCL:LI21:180:L1X_TOT_IQWT.PROC","1")

dbpf("ACCL:LI21:180:L1X_0_AWT.PROC","1")
dbpf("ACCL:LI21:180:L1X_1_AWT.PROC","1")
dbpf("ACCL:LI21:180:L1X_TOT_AWT.PROC","1")
dbpf("ACCL:LI21:180:L1X_0_POC.PROC","1")
dbpf("ACCL:LI21:180:L1X_1_POC.PROC","1")
dbpf("ACCL:LI21:180:L1X_0_APC.PROC","1")
dbpf("ACCL:LI21:180:L1X_1_APC.PROC","1")
dbpf("ACCL:LI21:180:L1X_0_AVC.PROC","1")
dbpf("ACCL:LI21:180:L1X_1_AVC.PROC","1")
dbpf("ACCL:LI21:180:L1X_PSMOOTH.PROC","1")
dbpf("ACCL:LI21:180:L1X_ASMOOTH.PROC","1")
dbpf("ACCL:LI21:180:L1X_PCORMIN.PROC","1")
dbpf("ACCL:LI21:180:L1X_PCORMAX.PROC","1")
dbpf("ACCL:LI21:180:L1X_ACORMIN.PROC","1")
dbpf("ACCL:LI21:180:L1X_ACORMAX.PROC","1")
dbpf("ACCL:LI21:180:L1X_ASETMIN.PROC","1")
dbpf("ACCL:LI21:180:L1X_ASETMAX.PROC","1")
dbpf("ACCL:LI21:180:L1X_QSCALE.PROC","1")
dbpf("ACCL:LI21:180:L1X_ISCALE.PROC","1")
# Default is for values to be sent. Convention is non-intuitive so that
# DISV=1 can be used. Val of this bo record compared to DISV and if they
# match, then sending to PAC is disabled. Therefore enabled = 0.
dbpf("ACCL:LI21:180:L1X_SEND","1")
dbpf("ACCL:LI21:180:L1X_PHAS_FB.PROC","1")
dbpf("ACCL:LI21:180:L1X_AMPL_FB.PROC","1")
dbpf("ACCL:LI21:180:L1X_PRV_ASET.PROC","1") # don't let it go below 100
dbpf("ACCL:LI21:180:L1X_PDES.PROC","1")
dbpf("ACCL:LI21:180:L1X_ADES.PROC","1")
dbpf("ACCL:LI21:180:L1X_PWR_THLD.PROC","1")

dbpf("ACCL:LI21:180:L1X_3_POC.PROC". "1")
dbpf("ACCL:LI21:180:L1X_3_AVC.PROC", "1")
dbpf("ACCL:LI21:180:L1X_3_APC.PROC", "1")

# Set initial values for global feedback

dbpf("LLRF:IN20:RH:G_L0_FB_CTL", "OFF")
dbpf("LLRF:LI21:RH:G_L1_FB_CTL", "OFF")

# 7/3/8: Needed for BSA
dbpf("LASR:IN20:1:LSR_0_NRPA.MDEL","-1") #11/23/8 differs from st-prod-hybrid
dbpf("GUN:IN20:1:GN1_PAVG.MDEL","-1")
dbpf("GUN:IN20:1:GN1_AAVG.MDEL","-1")
dbpf("ACCL:IN20:300:L0A_PAVG.MDEL","-1")
dbpf("ACCL:IN20:300:L0A_AAVG.MDEL","-1")
dbpf("ACCL:IN20:400:L0B_PAVG.MDEL","-1")
dbpf("ACCL:IN20:400:L0B_AAVG.MDEL","-1")
dbpf("PCAV:IN20:365:PH1_PAVG.MDEL","-1")
dbpf("PCAV:IN20:365:PH1_AAVG.MDEL","-1")
dbpf("TCAV:IN20:490:TC0_PAVG.MDEL","-1")
dbpf("TCAV:IN20:490:TC0_AAVG.MDEL","-1")
dbpf("ACCL:LI21:1:L1S_PAVG.MDEL","-1")
dbpf("ACCL:LI21:1:L1S_AAVG.MDEL","-1")
dbpf("ACCL:LI21:180:L1X_PAVG.MDEL","-1")
dbpf("ACCL:LI21:180:L1X_AAVG.MDEL","-1")
dbpf("PCAV:LI21:300:PH2_PAVG.MDEL","-1")
dbpf("PCAV:LI21:300:PH2_AAVG.MDEL","-1")

dbpf("PCAV:IN20:365:PH1_0_POC.PROC","1")
dbpf("PCAV:IN20:365:PH1_1_POC.PROC","1")
dbpf("PCAV:IN20:365:PH1_0_AVC.PROC","1")
dbpf("PCAV:IN20:365:PH1_1_AVC.PROC","1")
dbpf("PCAV:IN20:365:PH1_0_APC.PROC","1")
dbpf("PCAV:IN20:365:PH1_1_APC.PROC","1")
dbpf("PCAV:IN20:365:PH1_0_PWT.PROC","1")
dbpf("PCAV:IN20:365:PH1_1_PWT.PROC","1")
dbpf("PCAV:IN20:365:PH1_0_AWT.PROC","1")
dbpf("PCAV:IN20:365:PH1_1_AWT.PROC","1")

dbpf("PCAV:LI21:300:PH2_2_POC.PROC","1")
dbpf("PCAV:LI21:300:PH2_3_POC.PROC","1")
dbpf("PCAV:LI21:300:PH2_2_AVC.PROC","1")
dbpf("PCAV:LI21:300:PH2_3_AVC.PROC","1")
dbpf("PCAV:LI21:300:PH2_2_APC.PROC","1")
dbpf("PCAV:LI21:300:PH2_3_APC.PROC","1")
dbpf("PCAV:LI21:300:PH2_2_PWT.PROC","1")
dbpf("PCAV:LI21:300:PH2_3_PWT.PROC","1")
dbpf("PCAV:LI21:300:PH2_2_AWT.PROC","1")
dbpf("PCAV:LI21:300:PH2_3_AWT.PROC","1")

dbpf("PCAV:IN20:365:PH1_0_S_X_0.PROC","1")
dbpf("PCAV:IN20:365:PH1_0_S_X_1.PROC","1")
dbpf("PCAV:IN20:365:PH1_1_S_X_0.PROC","1")
dbpf("PCAV:IN20:365:PH1_1_S_X_1.PROC","1")
dbpf("PCAV:IN20:365:PH1_0_S_A_0.PROC","1")
dbpf("PCAV:IN20:365:PH1_0_S_W_0.PROC","1")
dbpf("PCAV:IN20:365:PH1_1_S_A_0.PROC","1")
dbpf("PCAV:IN20:365:PH1_1_S_W_0.PROC","1")
dbpf("PCAV:IN20:365:PH1_0_X_OFF.PROC","1")
dbpf("PCAV:IN20:365:PH1_1_X_OFF.PROC","1")
dbpf("PCAV:IN20:365:PH1_PWR_THLD.PROC","1")  # 2/10/9 new

dbpf("PCAV:LI21:300:PH2_2_S_X_0.PROC","1")
dbpf("PCAV:LI21:300:PH2_2_S_X_1.PROC","1")
dbpf("PCAV:LI21:300:PH2_3_S_X_0.PROC","1")
dbpf("PCAV:LI21:300:PH2_3_S_X_1.PROC","1")
dbpf("PCAV:LI21:300:PH2_2_S_A_0.PROC","1")
dbpf("PCAV:LI21:300:PH2_2_S_W_0.PROC","1")
dbpf("PCAV:LI21:300:PH2_3_S_A_0.PROC","1")
dbpf("PCAV:LI21:300:PH2_3_S_W_0.PROC","1")
dbpf("PCAV:LI21:300:PH2_2_X_OFF.PROC","1")
dbpf("PCAV:LI21:300:PH2_3_X_OFF.PROC","1")
dbpf("PCAV:LI21:300:PH2_PWR_THLD.PROC","1")  # 2/10/9 new

# 2/10/9 moved to $IOC/<host>/startup.cmd AFTER post_st.cmd
# Start streams from PADs 
#dbpf("LASR:IN20:1:LSR_ACCESS","0") 
#dbpf("GUN:IN20:1:GN1_ACCESS","0") 
#dbpf("ACCL:IN20:350:L0_ACCESS","0") 
#dbpf("PCAV:IN20:365:PH1_ACCESS","0")
#dbpf("TCAV:IN20:490:TC0_ACCESS","0")
#dbpf("ACCL:LI21:1:L1S_ACCESS","0")
#dbpf("ACCL:LI21:180:L1X_ACCESS","0")