record(ai, "$(BASE)FSCAN:PROGRESS") { field(DESC, "Scan progress") field(VAL, "0") field(EGU, "%") field(HOPR, "100") field(PINI, "YES") } record(longout, "$(BASE)FSCAN:NACQ") { field(DESC, "Freq scan n points at each freq") field(VAL, "4") field(PINI, "YES") info(autosaveFields, "VAL") } record(longout, "$(BASE)FSCAN:FREQ_STEP_SIZE") { field(DESC, "Freq scan step size") field(VAL, "100000") field(DRVL, "0") field(DRVH, "100000") field(EGU, "Hz") field(PINI, "YES") info(autosaveFields, "VAL") } record(longout, "$(BASE)FSCAN:FREQ_START") { field(DESC, "Freq scan range start") field(VAL, "-500000") field(EGU, "Hz") field(PINI, "YES") info(autosaveFields, "VAL") } record(longout, "$(BASE)FSCAN:FREQ_STOP") { field(DESC, "Freq scan range stop") field(VAL, "500000") field(EGU, "Hz") field(PINI, "YES") info(autosaveFields, "VAL") } # Give shift mode its own step setting, as # users are more likely to want to adjust this record(longout, "$(BASE)FSCAN:SHIFT_FREQ_STEP_SIZE") { field(DESC, "Freq shift step size") field(VAL, "100000") field(DRVL, "0") field(DRVH, "800000") field(EGU, "Hz") field(PINI, "YES") info(autosaveFields, "VAL") } record(mbbo, "$(BASE)FSCAN:START") { field(DESC, "Freq scan start request") field(SCAN, "Passive") field(ZRVL, "0") field(ZRST, "No request") field(ONVL, "1") field(ONST, "Search") field(TWVL, "2") field(TWST, "Shift") field(VAL, "0") } record(bo, "$(BASE)FSCAN:ABORT") { field(DESC, "Freq scan stop") field(VAL, "0") } record(mbbi, "$(BASE)FSCAN:STAT") { field(DESC, "Freq scan status") field(ZRVL, "0") field(ZRST, "Await request") field(ONVL, "1") field(ONST, "No cav selected") field(ONSV, "MAJOR") field(TWVL, "2") field(TWST, "Bad range") field(TWSV, "MAJOR") field(THVL, "3") field(THST, "Search in progress") field(THSV, "MINOR") field(FRVL, "4") field(FRST, "Shift mode") field(FRSV, "MINOR") field(FVVL, "5") field(FVST, "Scan done") field(SXVL, "6") field(SXST, "Scan aborted") field(SXSV, "MAJOR") field(SVVL, "7") field(SVST, "Freq restore fail") field(SVSV, "MAJOR") field(PINI, "YES") info(autosaveFields, "VAL") } # RMS threshold below which detune reading # considered valid record(ai, "$(BASE)FSCAN:RMS_THRESH") { field(DESC, "Chirp scan RMS check threshold") field(VAL, "10") field(EGU, "Hz") field(PINI, "YES") info(autosaveFields, "VAL") } # Frequency delta between which consider multiple modes # to be the same mode record(ai, "$(BASE)FSCAN:MODE_OVERLAP") { field(DESC, "Mode overlap delta") field(VAL, "1000") field(EGU, "Hz") field(PINI, "YES") info(autosaveFields, "VAL") } # Monitor actual frequency shift of RFS/PRC # When the difference between it and the scan setpoint # at that step is below this threshold, consider it to # have reached the setting # Typically difference is between ~0 and 40 Hz record(ai, "$(BASE)FSCAN:FREQ_THRESH") { field(DESC, "Exact freq shift matches setpoint") field(VAL, "100") field(EGU, "Hz") field(PINI, "YES") info(autosaveFields, "VAL") } record(ai, "$(BASE)FSCAN:ACQ_DLY") { field(DESC, "Freq scan wait between df acq ") field(EGU, "s") field(VAL, "1.0") field(PINI, "YES") info(autosaveFields, "VAL") } record(stringin, "$(BASE)FSCAN:MSG") { field(VAL, "") field(PINI, "YES") info(autosaveFields, "VAL") } record(mbbo, "$(BASE)FSCAN:DBG") { field(DESC, "Freq scan debug verbosity") field(SCAN, "Passive") field(ZRVL, "0") field(ZRST, "Off") field(ONVL, "1") field(ONST, "Low") field(TWVL, "2") field(TWST, "Medium") field(THVL, "3") field(THST, "High") field(VAL, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # NELM must match that in freq_cavity_common.template # and MAX_NOFFSET in chirpscan.st record(aai, "$(BASE)FSCAN:OFFSETWF") { field(DESC, "Freq scan values") field(FTVL, "DOUBLE") field(NELM, "$(NELM)") field(EGU, "Hz") } record(ai, "$(BASE)FSCAN:8PI9_START") { field(DESC, "8pi/9 search range start") field(VAL, "-850000") field(EGU, "Hz") field(PINI, "YES") info(autosaveFields, "VAL") } record(ai, "$(BASE)FSCAN:8PI9_STOP") { field(DESC, "8pi/9 search range stop") field(VAL, "-700000") field(EGU, "Hz") field(PINI, "YES") info(autosaveFields, "VAL") } record(ai, "$(BASE)FSCAN:7PI9_START") { field(DESC, "7pi/9 search range start") field(VAL, "-3500000") field(EGU, "Hz") field(PINI, "YES") info(autosaveFields, "VAL") } record(ai, "$(BASE)FSCAN:7PI9_STOP") { field(DESC, "7pi/9 search range stop") field(VAL, "-2700000") field(EGU, "Hz") field(PINI, "YES") info(autosaveFields, "VAL") } record(calc, "$(BASE)FSCAN:FDESVIS") { field(DESC, "Display visibility") field(CALC, "A#4?0:(B=C)?0:1") field(INPA, "$(BASE)FSCAN:STAT CP") field(INPB, "$(BASE)FSCAN:FDES CP") field(INPC, "$(BASE)FSET CP") field(PINI, "YES") } record(longout, "$(BASE)FSCAN:FDES") { field(DESC, "Scan freq shift request") field(VAL, "0") field(EGU, "Hz") field(PINI, "YES") info(autosaveFields, "VAL") } record(calcout, "$(BASE)FSCAN:FDESINCR") { field(DESC, "Increment freq shift request") field(CALC, "A+B") field(INPA, "$(BASE)FSCAN:FDES") field(INPB, "50000") field(OOPT, "Every Time") field(OUT, "$(BASE)FSCAN:FDES PP") } record(calcout, "$(BASE)FSCAN:FDESDECR") { field(DESC, "Decrement freq shift request") field(CALC, "A-B") field(INPA, "$(BASE)FSCAN:FDES") field(INPB, "50000") field(OOPT, "Every Time") field(OUT, "$(BASE)FSCAN:FDES PP") } record(longout, "$(BASE)FSET") { field(DESC, "Set rack frequency offset") field(FLNK, "$(BASE)FSET_SUB") } record(aSub, "$(BASE)FSET_SUB") { field(DESC, "Set RFS/PRC freq offset") field(INAM, "") field(SNAM, "Set Rack Freq Offset") field(SCAN, "Passive") # Inputs field(FTA, "LONG") field(NOA, "1") field(INPA, "$(BASE)FSET") # Desired rack freq offset from nominal # Outputs # VALA = PRC phase step high field(FTVA, "LONG") field(NOVA, "1") # VALB = RFS phase step field(FTVB, "LONG") field(NOVB, "1") # VALC = calculated exact offset field(FTVC, "DOUBLE") field(NOVC, "1") # VALD = mask of which FSET_GO links to process field(FTVD, "USHORT") field(NOVD, "1") field(FLNK, "$(BASE)FSET_GO") } record(seq, "$(BASE)FSET_GO") { field(DESC, "Reset PRC/RFS phase accumulator") field(SELM, "Mask") field(SELL, "$(BASE)FSET_SUB.VALD") field(DOL1, "$(BASE)FSET_SUB.VALA") field(LNK1, "$(PRC)DDS_PHASE_STEPH PP") field(DOL2, "$(BASE)FSET_SUB.VALB") field(LNK2, "$(CA)DDS_PHASE_STEP PP") field(DOL3, "$(BASE)FSET_SUB.VALB") field(LNK3, "$(CB)DDS_PHASE_STEP PP") field(DOL4, "$(BASE)FSET_SUB.VALB") field(LNK4, "$(CC)DDS_PHASE_STEP PP") field(DOL5, "$(BASE)FSET_SUB.VALB") field(LNK5, "$(CD)DDS_PHASE_STEP PP") field(DLY6, "1") field(DOL6, "1") field(LNK6, "$(BASE)FREQ_RESET PP") } record(seq, "$(BASE)FREQ_RESET") { field(DESC, "Reset PRC/RFS phase accumulators") field(SELM, "All") field(DOL1, "1") field(LNK1, "$(PRC)DDS_PHASE_RESET PP") field(DOL2, "1") field(LNK2, "$(CA)DDS_PHASE_RESET PP") field(DOL3, "1") field(LNK3, "$(CB)DDS_PHASE_RESET PP") field(DOL4, "1") field(LNK4, "$(CC)DDS_PHASE_RESET PP") field(DOL5, "1") field(LNK5, "$(CD)DDS_PHASE_RESET PP") } record(aSub, "$(BASE)FREQ_OFFSET_SUB") { field(DESC, "Calculate RFS/PRC freq offset") field(INAM, "Init Freq Offset") field(SNAM, "Calculate Freq Offset") field(SCAN, "Passive") field(PINI, "YES") field(BRSV, "INVALID") # Inputs field(FTA, "LONG") field(NOA, "1") field(INPA, "$(PRC)DDS_PHASE_STEPH_RBV CP") field(FTB, "LONG") field(NOB, "1") field(INPB, "$(CA)DDS_PHASE_STEP_RBV CP") field(FTC, "LONG") field(NOC, "1") field(INPC, "$(CB)DDS_PHASE_STEP_RBV CP") field(FTD, "LONG") field(NOD, "1") field(INPD, "$(CC)DDS_PHASE_STEP_RBV CP") field(FTE, "LONG") field(NOE, "1") field(INPE, "$(CD)DDS_PHASE_STEP_RBV CP") # Outputs # VALA = determined frequency offset # or if no consistent value determined, # last value with INVALID severity field(FTVA, "DOUBLE") field(NOVA, "1") field(FLNK, "$(BASE)FREQ_OFFSET") } record(ai, "$(BASE)FREQ_OFFSET") { field(DESC, "Freq offset from nominal") field(INP, "$(BASE)FREQ_OFFSET_SUB.VALA MSI") field(PREC, "1") field(EGU, "Hz") field(LOW, "-0.1") field(LSV, "MINOR") field(HIGH, "0.1") field(HSV, "MINOR") } # For a system that is locked to a Phase Reference Line, # the standard frequency scan behavior is: # 1. Turn off PRL tracking # 2. Perform frequency shift/scan # 3. Turn on PRL tracking # To do this, the PRLPV macro must be passed to # the chirpScan program. # This record, FSCAN:PRL_OVERRIDE, can override # that behavior at run-time. Set it to 1 # to leave PRL settings untouched during scan. record(bo, "$(BASE)FSCAN:PRL_OVERRIDE") { field(DESC, "Freq scan PRL override") field(ZNAM, "Disable PRL tracking") field(ONAM, "Don't change PRL tracking") field(OSV, "MINOR") field(VAL, "0") field(PINI, "YES") info(autosaveFields, "VAL") }