Depending on the format type, different record fields are used
for output and input. The variable x stands for the
written or read value.
%f):x=(VAL-AOFF)/ASLOVAL=(x*ASLO+AOFF)*(1.0-SMOO)+VAL*SMOOASLO==0.0, it is treated as 1.0.
Default values are ASLO=1.0, AOFF=0.0,
SMOO=0.0.UDF is cleared.
%i):x=RVALRVAL=xVAL=(((RVAL+ROFF)*ASLO+AOFF)*ESLO+EOFF)*(1.0-SMOO)+VAL*SMOO
if LINR=="LINEAR".
ESLO and EOFF might be set in the record
definition. StreamDevice does not set it. For example,
EOFF=-10 and ESLO=0.000305180437934
(=20.0/0xFFFF) maps 0x0000 to -10.0, 0x7FFF to 0.0 and 0xFFFF to 10.0.
Using unsigned formats with values ≥ 0x800000 gives different results
on 64 bit machines.
%{):%s):
During initialization, the @init handler is executed, if present.
In contrast to normal operation, in DOUBLE input SMOO is ignored
(treated as 0.0).
aai aao ao bi bo mbbi mbbo mbbiDirect mbboDirect longin longout stringin stringout waveform calcout scalcout
Dirk Zimoch, 2005