#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK1") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):1:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH1")
  field(INPA, "EDEF:$(LOC):1:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT1")
  field(INPD, "$(DEVICE):DONE1")
  field(INPU, "EDEF:$(LOC):1:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):1:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE1")
  field(INPI, "EDEF:$(LOC):1:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):1:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE1") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):1:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE1")
}

record(seq, "$(DEVICE):RESETSEQ1") {
  field(DESC, "EDEF 1 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT1 PP")
  field(LNK2, "$(DEVICE):CHECK1")
  field(LNK3, "$(DEVICE):CHECK1.Y")
  field(LNK4, "$(DEVICE):CHECK1.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT1")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE1")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT1 PP")
}

record(bo, "$(DEVICE):INIT1") {
  field(DOL, "$(DEVICE):CHECK1")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH1") {
  field(FLNK, "$(DEVICE):MEASCNT1")
  field(DOL, "$(DEVICE):CHECK1")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE1") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE1")
  field(INPC, "$(DEVICE):CHECK1.Q")
}

record(calcout, "$(DEVICE):MEASCNT1") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE1")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH1")
  field(INPB, "$(DEVICE):MEASCNT1")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK1",1538,2184,0,0,"$(DEVICE):CHECK1")
#! Field("$(DEVICE):CHECK1.FLNK",16777215,1,"$(DEVICE):CHECK1.FLNK")
#! Link("$(DEVICE):CHECK1.FLNK","$(DEVICE):MODMATCH1")
#! Field("$(DEVICE):CHECK1.INPF",16777215,1,"$(DEVICE):CHECK1.INPF")
#! Field("$(DEVICE):CHECK1.INPP",16777215,1,"$(DEVICE):CHECK1.INPP")
#! Field("$(DEVICE):CHECK1.INPW",16777215,1,"$(DEVICE):CHECK1.INPW")
#! Field("$(DEVICE):CHECK1.Y",16777215,0,"$(DEVICE):CHECK1.Y")
#! Field("$(DEVICE):CHECK1.Z",16777215,0,"$(DEVICE):CHECK1.Z")
#! Field("$(DEVICE):CHECK1.VAL",16777215,1,"$(DEVICE):CHECK1.VAL")
#! Field("$(DEVICE):CHECK1.INPA",16777215,1,"$(DEVICE):CHECK1.INPA")
#! Field("$(DEVICE):CHECK1.INPB",16777215,1,"$(DEVICE):CHECK1.INPB")
#! Link("$(DEVICE):CHECK1.INPB","$(DEVICE):MEASCNT1.VAL")
#! Field("$(DEVICE):CHECK1.Q",16777215,1,"$(DEVICE):CHECK1.Q")
#! Field("$(DEVICE):CHECK1.INPD",16777215,1,"$(DEVICE):CHECK1.INPD")
#! Link("$(DEVICE):CHECK1.INPD","$(DEVICE):DONE1.VAL")
#! Field("$(DEVICE):CHECK1.INPU",16777215,1,"$(DEVICE):CHECK1.INPU")
#! Field("$(DEVICE):CHECK1.INPV",16777215,1,"$(DEVICE):CHECK1.INPV")
#! Field("$(DEVICE):CHECK1.SDIS",16777215,0,"$(DEVICE):CHECK1.SDIS")
#! Link("$(DEVICE):CHECK1.SDIS","$(DEVICE):STATE1.VAL")
#! Field("$(DEVICE):CHECK1.INPI",16777215,1,"$(DEVICE):CHECK1.INPI")
#! Field("$(DEVICE):CHECK1.INPJ",16777215,1,"$(DEVICE):CHECK1.INPJ")
#! Record("$(DEVICE):STATE1",1154,2201,0,1,"$(DEVICE):STATE1")
#! Field("$(DEVICE):STATE1.INPA",16777215,1,"$(DEVICE):STATE1.INPA")
#! Field("$(DEVICE):STATE1.INPB",16777215,1,"$(DEVICE):STATE1.INPB")
#! Link("$(DEVICE):STATE1.INPB","$(DEVICE):DONE1.VAL")
#! Field("$(DEVICE):STATE1.VAL",16777215,1,"$(DEVICE):STATE1.VAL")
#! Record("$(DEVICE):RESETSEQ1",1144,2895,0,0,"$(DEVICE):RESETSEQ1")
#! Field("$(DEVICE):RESETSEQ1.LNK1",16777215,1,"$(DEVICE):RESETSEQ1.LNK1")
#! Link("$(DEVICE):RESETSEQ1.LNK1","$(DEVICE):INIT1.VAL")
#! Field("$(DEVICE):RESETSEQ1.LNK2",16777215,1,"$(DEVICE):RESETSEQ1.LNK2")
#! Link("$(DEVICE):RESETSEQ1.LNK2","$(DEVICE):CHECK1.VAL")
#! Field("$(DEVICE):RESETSEQ1.LNK3",16777215,1,"$(DEVICE):RESETSEQ1.LNK3")
#! Link("$(DEVICE):RESETSEQ1.LNK3","$(DEVICE):CHECK1.Y")
#! Field("$(DEVICE):RESETSEQ1.LNK4",16777215,1,"$(DEVICE):RESETSEQ1.LNK4")
#! Link("$(DEVICE):RESETSEQ1.LNK4","$(DEVICE):CHECK1.Z")
#! Field("$(DEVICE):RESETSEQ1.LNK5",16777215,1,"$(DEVICE):RESETSEQ1.LNK5")
#! Link("$(DEVICE):RESETSEQ1.LNK5","$(DEVICE):MEASCNT1.VAL")
#! Field("$(DEVICE):RESETSEQ1.LNK6",16777215,1,"$(DEVICE):RESETSEQ1.LNK6")
#! Link("$(DEVICE):RESETSEQ1.LNK6","$(DEVICE):DONE1.VAL")
#! Field("$(DEVICE):RESETSEQ1.LNK8",16777215,1,"$(DEVICE):RESETSEQ1.LNK8")
#! Link("$(DEVICE):RESETSEQ1.LNK8","$(DEVICE):INIT1.VAL")
#! Record("$(DEVICE):INIT1",2010,2954,0,1,"$(DEVICE):INIT1")
#! Field("$(DEVICE):INIT1.VAL",16777215,0,"$(DEVICE):INIT1.VAL")
#! Field("$(DEVICE):INIT1.DOL",16777215,0,"$(DEVICE):INIT1.DOL")
#! Link("$(DEVICE):INIT1.DOL","$(DEVICE):CHECK1.VAL")
#! Record("$(DEVICE):MODMATCH1",1938,2448,0,0,"$(DEVICE):MODMATCH1")
#! Field("$(DEVICE):MODMATCH1.DOL",16777215,0,"$(DEVICE):MODMATCH1.DOL")
#! Link("$(DEVICE):MODMATCH1.DOL","$(DEVICE):CHECK1.VAL")
#! Field("$(DEVICE):MODMATCH1.FLNK",16777215,1,"$(DEVICE):MODMATCH1.FLNK")
#! Link("$(DEVICE):MODMATCH1.FLNK","$(DEVICE):MEASCNT1")
#! Field("$(DEVICE):MODMATCH1.VAL",16777215,1,"$(DEVICE):MODMATCH1.VAL")
#! Record("$(DEVICE):DONE1",2530,2306,0,0,"$(DEVICE):DONE1")
#! Field("$(DEVICE):DONE1.FLNK",16777215,0,"$(DEVICE):DONE1.FLNK")
#! Link("$(DEVICE):DONE1.FLNK","$(DEVICE):STATE1")
#! Field("$(DEVICE):DONE1.INPC",16777215,0,"$(DEVICE):DONE1.INPC")
#! Link("$(DEVICE):DONE1.INPC","$(DEVICE):CHECK1.Q")
#! Field("$(DEVICE):DONE1.VAL",16777215,0,"$(DEVICE):DONE1.VAL")
#! Record("$(DEVICE):MEASCNT1",2266,2526,0,0,"$(DEVICE):MEASCNT1")
#! Field("$(DEVICE):MEASCNT1.FLNK",16777215,1,"$(DEVICE):MEASCNT1.FLNK")
#! Link("$(DEVICE):MEASCNT1.FLNK","$(DEVICE):DONE1")
#! Field("$(DEVICE):MEASCNT1.VAL",16777215,0,"$(DEVICE):MEASCNT1.VAL")
#! Field("$(DEVICE):MEASCNT1.INPA",16777215,0,"$(DEVICE):MEASCNT1.INPA")
#! Link("$(DEVICE):MEASCNT1.INPA","$(DEVICE):MODMATCH1.VAL")
#! Field("$(DEVICE):MEASCNT1.INPB",16777215,0,"$(DEVICE):MEASCNT1.INPB")
#! Link("$(DEVICE):MEASCNT1.INPB","$(DEVICE):MEASCNT1.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK2") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):2:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH2")
  field(INPA, "EDEF:$(LOC):2:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT2")
  field(INPD, "$(DEVICE):DONE2")
  field(INPU, "EDEF:$(LOC):2:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):2:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE2")
  field(INPI, "EDEF:$(LOC):2:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):2:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE2") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):2:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE2")
}

record(seq, "$(DEVICE):RESETSEQ2") {
  field(DESC, "EDEF 2 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT2 PP")
  field(LNK2, "$(DEVICE):CHECK2")
  field(LNK3, "$(DEVICE):CHECK2.Y")
  field(LNK4, "$(DEVICE):CHECK2.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT2")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE2")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT2 PP")
}

record(bo, "$(DEVICE):INIT2") {
  field(DOL, "$(DEVICE):CHECK2")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH2") {
  field(FLNK, "$(DEVICE):MEASCNT2")
  field(DOL, "$(DEVICE):CHECK2")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE2") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE2")
  field(INPC, "$(DEVICE):CHECK2.Q")
}

record(calcout, "$(DEVICE):MEASCNT2") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE2")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH2")
  field(INPB, "$(DEVICE):MEASCNT2")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK2",1538,2184,0,0,"$(DEVICE):CHECK2")
#! Field("$(DEVICE):CHECK2.FLNK",16777215,1,"$(DEVICE):CHECK2.FLNK")
#! Link("$(DEVICE):CHECK2.FLNK","$(DEVICE):MODMATCH2")
#! Field("$(DEVICE):CHECK2.INPF",16777215,1,"$(DEVICE):CHECK2.INPF")
#! Field("$(DEVICE):CHECK2.INPP",16777215,1,"$(DEVICE):CHECK2.INPP")
#! Field("$(DEVICE):CHECK2.INPW",16777215,1,"$(DEVICE):CHECK2.INPW")
#! Field("$(DEVICE):CHECK2.Y",16777215,0,"$(DEVICE):CHECK2.Y")
#! Field("$(DEVICE):CHECK2.Z",16777215,0,"$(DEVICE):CHECK2.Z")
#! Field("$(DEVICE):CHECK2.VAL",16777215,1,"$(DEVICE):CHECK2.VAL")
#! Field("$(DEVICE):CHECK2.INPA",16777215,1,"$(DEVICE):CHECK2.INPA")
#! Field("$(DEVICE):CHECK2.INPB",16777215,1,"$(DEVICE):CHECK2.INPB")
#! Link("$(DEVICE):CHECK2.INPB","$(DEVICE):MEASCNT2.VAL")
#! Field("$(DEVICE):CHECK2.Q",16777215,1,"$(DEVICE):CHECK2.Q")
#! Field("$(DEVICE):CHECK2.INPD",16777215,1,"$(DEVICE):CHECK2.INPD")
#! Link("$(DEVICE):CHECK2.INPD","$(DEVICE):DONE2.VAL")
#! Field("$(DEVICE):CHECK2.INPU",16777215,1,"$(DEVICE):CHECK2.INPU")
#! Field("$(DEVICE):CHECK2.INPV",16777215,1,"$(DEVICE):CHECK2.INPV")
#! Field("$(DEVICE):CHECK2.SDIS",16777215,0,"$(DEVICE):CHECK2.SDIS")
#! Link("$(DEVICE):CHECK2.SDIS","$(DEVICE):STATE2.VAL")
#! Field("$(DEVICE):CHECK2.INPI",16777215,1,"$(DEVICE):CHECK2.INPI")
#! Field("$(DEVICE):CHECK2.INPJ",16777215,1,"$(DEVICE):CHECK2.INPJ")
#! Record("$(DEVICE):STATE2",1154,2201,0,1,"$(DEVICE):STATE2")
#! Field("$(DEVICE):STATE2.INPA",16777215,1,"$(DEVICE):STATE2.INPA")
#! Field("$(DEVICE):STATE2.INPB",16777215,1,"$(DEVICE):STATE2.INPB")
#! Link("$(DEVICE):STATE2.INPB","$(DEVICE):DONE2.VAL")
#! Field("$(DEVICE):STATE2.VAL",16777215,1,"$(DEVICE):STATE2.VAL")
#! Record("$(DEVICE):RESETSEQ2",1144,2895,0,0,"$(DEVICE):RESETSEQ2")
#! Field("$(DEVICE):RESETSEQ2.LNK1",16777215,1,"$(DEVICE):RESETSEQ2.LNK1")
#! Link("$(DEVICE):RESETSEQ2.LNK1","$(DEVICE):INIT2.VAL")
#! Field("$(DEVICE):RESETSEQ2.LNK2",16777215,1,"$(DEVICE):RESETSEQ2.LNK2")
#! Link("$(DEVICE):RESETSEQ2.LNK2","$(DEVICE):CHECK2.VAL")
#! Field("$(DEVICE):RESETSEQ2.LNK3",16777215,1,"$(DEVICE):RESETSEQ2.LNK3")
#! Link("$(DEVICE):RESETSEQ2.LNK3","$(DEVICE):CHECK2.Y")
#! Field("$(DEVICE):RESETSEQ2.LNK4",16777215,1,"$(DEVICE):RESETSEQ2.LNK4")
#! Link("$(DEVICE):RESETSEQ2.LNK4","$(DEVICE):CHECK2.Z")
#! Field("$(DEVICE):RESETSEQ2.LNK5",16777215,1,"$(DEVICE):RESETSEQ2.LNK5")
#! Link("$(DEVICE):RESETSEQ2.LNK5","$(DEVICE):MEASCNT2.VAL")
#! Field("$(DEVICE):RESETSEQ2.LNK6",16777215,1,"$(DEVICE):RESETSEQ2.LNK6")
#! Link("$(DEVICE):RESETSEQ2.LNK6","$(DEVICE):DONE2.VAL")
#! Field("$(DEVICE):RESETSEQ2.LNK8",16777215,1,"$(DEVICE):RESETSEQ2.LNK8")
#! Link("$(DEVICE):RESETSEQ2.LNK8","$(DEVICE):INIT2.VAL")
#! Record("$(DEVICE):INIT2",2010,2954,0,1,"$(DEVICE):INIT2")
#! Field("$(DEVICE):INIT2.VAL",16777215,0,"$(DEVICE):INIT2.VAL")
#! Field("$(DEVICE):INIT2.DOL",16777215,0,"$(DEVICE):INIT2.DOL")
#! Link("$(DEVICE):INIT2.DOL","$(DEVICE):CHECK2.VAL")
#! Record("$(DEVICE):MODMATCH2",1938,2448,0,0,"$(DEVICE):MODMATCH2")
#! Field("$(DEVICE):MODMATCH2.DOL",16777215,0,"$(DEVICE):MODMATCH2.DOL")
#! Link("$(DEVICE):MODMATCH2.DOL","$(DEVICE):CHECK2.VAL")
#! Field("$(DEVICE):MODMATCH2.FLNK",16777215,1,"$(DEVICE):MODMATCH2.FLNK")
#! Link("$(DEVICE):MODMATCH2.FLNK","$(DEVICE):MEASCNT2")
#! Field("$(DEVICE):MODMATCH2.VAL",16777215,1,"$(DEVICE):MODMATCH2.VAL")
#! Record("$(DEVICE):DONE2",2530,2306,0,0,"$(DEVICE):DONE2")
#! Field("$(DEVICE):DONE2.FLNK",16777215,0,"$(DEVICE):DONE2.FLNK")
#! Link("$(DEVICE):DONE2.FLNK","$(DEVICE):STATE2")
#! Field("$(DEVICE):DONE2.INPC",16777215,0,"$(DEVICE):DONE2.INPC")
#! Link("$(DEVICE):DONE2.INPC","$(DEVICE):CHECK2.Q")
#! Field("$(DEVICE):DONE2.VAL",16777215,0,"$(DEVICE):DONE2.VAL")
#! Record("$(DEVICE):MEASCNT2",2266,2526,0,0,"$(DEVICE):MEASCNT2")
#! Field("$(DEVICE):MEASCNT2.FLNK",16777215,1,"$(DEVICE):MEASCNT2.FLNK")
#! Link("$(DEVICE):MEASCNT2.FLNK","$(DEVICE):DONE2")
#! Field("$(DEVICE):MEASCNT2.VAL",16777215,0,"$(DEVICE):MEASCNT2.VAL")
#! Field("$(DEVICE):MEASCNT2.INPA",16777215,0,"$(DEVICE):MEASCNT2.INPA")
#! Link("$(DEVICE):MEASCNT2.INPA","$(DEVICE):MODMATCH2.VAL")
#! Field("$(DEVICE):MEASCNT2.INPB",16777215,0,"$(DEVICE):MEASCNT2.INPB")
#! Link("$(DEVICE):MEASCNT2.INPB","$(DEVICE):MEASCNT2.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK3") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):3:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH3")
  field(INPA, "EDEF:$(LOC):3:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT3")
  field(INPD, "$(DEVICE):DONE3")
  field(INPU, "EDEF:$(LOC):3:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):3:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE3")
  field(INPI, "EDEF:$(LOC):3:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):3:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE3") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):3:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE3")
}

record(seq, "$(DEVICE):RESETSEQ3") {
  field(DESC, "EDEF 3 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT3 PP")
  field(LNK2, "$(DEVICE):CHECK3")
  field(LNK3, "$(DEVICE):CHECK3.Y")
  field(LNK4, "$(DEVICE):CHECK3.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT3")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE3")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT3 PP")
}

record(bo, "$(DEVICE):INIT3") {
  field(DOL, "$(DEVICE):CHECK3")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH3") {
  field(FLNK, "$(DEVICE):MEASCNT3")
  field(DOL, "$(DEVICE):CHECK3")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE3") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE3")
  field(INPC, "$(DEVICE):CHECK3.Q")
}

record(calcout, "$(DEVICE):MEASCNT3") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE3")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH3")
  field(INPB, "$(DEVICE):MEASCNT3")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK3",1538,2184,0,0,"$(DEVICE):CHECK3")
#! Field("$(DEVICE):CHECK3.FLNK",16777215,1,"$(DEVICE):CHECK3.FLNK")
#! Link("$(DEVICE):CHECK3.FLNK","$(DEVICE):MODMATCH3")
#! Field("$(DEVICE):CHECK3.INPF",16777215,1,"$(DEVICE):CHECK3.INPF")
#! Field("$(DEVICE):CHECK3.INPP",16777215,1,"$(DEVICE):CHECK3.INPP")
#! Field("$(DEVICE):CHECK3.INPW",16777215,1,"$(DEVICE):CHECK3.INPW")
#! Field("$(DEVICE):CHECK3.Y",16777215,0,"$(DEVICE):CHECK3.Y")
#! Field("$(DEVICE):CHECK3.Z",16777215,0,"$(DEVICE):CHECK3.Z")
#! Field("$(DEVICE):CHECK3.VAL",16777215,1,"$(DEVICE):CHECK3.VAL")
#! Field("$(DEVICE):CHECK3.INPA",16777215,1,"$(DEVICE):CHECK3.INPA")
#! Field("$(DEVICE):CHECK3.INPB",16777215,1,"$(DEVICE):CHECK3.INPB")
#! Link("$(DEVICE):CHECK3.INPB","$(DEVICE):MEASCNT3.VAL")
#! Field("$(DEVICE):CHECK3.Q",16777215,1,"$(DEVICE):CHECK3.Q")
#! Field("$(DEVICE):CHECK3.INPD",16777215,1,"$(DEVICE):CHECK3.INPD")
#! Link("$(DEVICE):CHECK3.INPD","$(DEVICE):DONE3.VAL")
#! Field("$(DEVICE):CHECK3.INPU",16777215,1,"$(DEVICE):CHECK3.INPU")
#! Field("$(DEVICE):CHECK3.INPV",16777215,1,"$(DEVICE):CHECK3.INPV")
#! Field("$(DEVICE):CHECK3.SDIS",16777215,0,"$(DEVICE):CHECK3.SDIS")
#! Link("$(DEVICE):CHECK3.SDIS","$(DEVICE):STATE3.VAL")
#! Field("$(DEVICE):CHECK3.INPI",16777215,1,"$(DEVICE):CHECK3.INPI")
#! Field("$(DEVICE):CHECK3.INPJ",16777215,1,"$(DEVICE):CHECK3.INPJ")
#! Record("$(DEVICE):STATE3",1154,2201,0,1,"$(DEVICE):STATE3")
#! Field("$(DEVICE):STATE3.INPA",16777215,1,"$(DEVICE):STATE3.INPA")
#! Field("$(DEVICE):STATE3.INPB",16777215,1,"$(DEVICE):STATE3.INPB")
#! Link("$(DEVICE):STATE3.INPB","$(DEVICE):DONE3.VAL")
#! Field("$(DEVICE):STATE3.VAL",16777215,1,"$(DEVICE):STATE3.VAL")
#! Record("$(DEVICE):RESETSEQ3",1144,2895,0,0,"$(DEVICE):RESETSEQ3")
#! Field("$(DEVICE):RESETSEQ3.LNK1",16777215,1,"$(DEVICE):RESETSEQ3.LNK1")
#! Link("$(DEVICE):RESETSEQ3.LNK1","$(DEVICE):INIT3.VAL")
#! Field("$(DEVICE):RESETSEQ3.LNK2",16777215,1,"$(DEVICE):RESETSEQ3.LNK2")
#! Link("$(DEVICE):RESETSEQ3.LNK2","$(DEVICE):CHECK3.VAL")
#! Field("$(DEVICE):RESETSEQ3.LNK3",16777215,1,"$(DEVICE):RESETSEQ3.LNK3")
#! Link("$(DEVICE):RESETSEQ3.LNK3","$(DEVICE):CHECK3.Y")
#! Field("$(DEVICE):RESETSEQ3.LNK4",16777215,1,"$(DEVICE):RESETSEQ3.LNK4")
#! Link("$(DEVICE):RESETSEQ3.LNK4","$(DEVICE):CHECK3.Z")
#! Field("$(DEVICE):RESETSEQ3.LNK5",16777215,1,"$(DEVICE):RESETSEQ3.LNK5")
#! Link("$(DEVICE):RESETSEQ3.LNK5","$(DEVICE):MEASCNT3.VAL")
#! Field("$(DEVICE):RESETSEQ3.LNK6",16777215,1,"$(DEVICE):RESETSEQ3.LNK6")
#! Link("$(DEVICE):RESETSEQ3.LNK6","$(DEVICE):DONE3.VAL")
#! Field("$(DEVICE):RESETSEQ3.LNK8",16777215,1,"$(DEVICE):RESETSEQ3.LNK8")
#! Link("$(DEVICE):RESETSEQ3.LNK8","$(DEVICE):INIT3.VAL")
#! Record("$(DEVICE):INIT3",2010,2954,0,1,"$(DEVICE):INIT3")
#! Field("$(DEVICE):INIT3.VAL",16777215,0,"$(DEVICE):INIT3.VAL")
#! Field("$(DEVICE):INIT3.DOL",16777215,0,"$(DEVICE):INIT3.DOL")
#! Link("$(DEVICE):INIT3.DOL","$(DEVICE):CHECK3.VAL")
#! Record("$(DEVICE):MODMATCH3",1938,2448,0,0,"$(DEVICE):MODMATCH3")
#! Field("$(DEVICE):MODMATCH3.DOL",16777215,0,"$(DEVICE):MODMATCH3.DOL")
#! Link("$(DEVICE):MODMATCH3.DOL","$(DEVICE):CHECK3.VAL")
#! Field("$(DEVICE):MODMATCH3.FLNK",16777215,1,"$(DEVICE):MODMATCH3.FLNK")
#! Link("$(DEVICE):MODMATCH3.FLNK","$(DEVICE):MEASCNT3")
#! Field("$(DEVICE):MODMATCH3.VAL",16777215,1,"$(DEVICE):MODMATCH3.VAL")
#! Record("$(DEVICE):DONE3",2530,2306,0,0,"$(DEVICE):DONE3")
#! Field("$(DEVICE):DONE3.FLNK",16777215,0,"$(DEVICE):DONE3.FLNK")
#! Link("$(DEVICE):DONE3.FLNK","$(DEVICE):STATE3")
#! Field("$(DEVICE):DONE3.INPC",16777215,0,"$(DEVICE):DONE3.INPC")
#! Link("$(DEVICE):DONE3.INPC","$(DEVICE):CHECK3.Q")
#! Field("$(DEVICE):DONE3.VAL",16777215,0,"$(DEVICE):DONE3.VAL")
#! Record("$(DEVICE):MEASCNT3",2266,2526,0,0,"$(DEVICE):MEASCNT3")
#! Field("$(DEVICE):MEASCNT3.FLNK",16777215,1,"$(DEVICE):MEASCNT3.FLNK")
#! Link("$(DEVICE):MEASCNT3.FLNK","$(DEVICE):DONE3")
#! Field("$(DEVICE):MEASCNT3.VAL",16777215,0,"$(DEVICE):MEASCNT3.VAL")
#! Field("$(DEVICE):MEASCNT3.INPA",16777215,0,"$(DEVICE):MEASCNT3.INPA")
#! Link("$(DEVICE):MEASCNT3.INPA","$(DEVICE):MODMATCH3.VAL")
#! Field("$(DEVICE):MEASCNT3.INPB",16777215,0,"$(DEVICE):MEASCNT3.INPB")
#! Link("$(DEVICE):MEASCNT3.INPB","$(DEVICE):MEASCNT3.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK4") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):4:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH4")
  field(INPA, "EDEF:$(LOC):4:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT4")
  field(INPD, "$(DEVICE):DONE4")
  field(INPU, "EDEF:$(LOC):4:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):4:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE4")
  field(INPI, "EDEF:$(LOC):4:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):4:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE4") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):4:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE4")
}

record(seq, "$(DEVICE):RESETSEQ4") {
  field(DESC, "EDEF 4 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT4 PP")
  field(LNK2, "$(DEVICE):CHECK4")
  field(LNK3, "$(DEVICE):CHECK4.Y")
  field(LNK4, "$(DEVICE):CHECK4.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT4")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE4")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT4 PP")
}

record(bo, "$(DEVICE):INIT4") {
  field(DOL, "$(DEVICE):CHECK4")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH4") {
  field(FLNK, "$(DEVICE):MEASCNT4")
  field(DOL, "$(DEVICE):CHECK4")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE4") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE4")
  field(INPC, "$(DEVICE):CHECK4.Q")
}

record(calcout, "$(DEVICE):MEASCNT4") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE4")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH4")
  field(INPB, "$(DEVICE):MEASCNT4")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK4",1538,2184,0,0,"$(DEVICE):CHECK4")
#! Field("$(DEVICE):CHECK4.FLNK",16777215,1,"$(DEVICE):CHECK4.FLNK")
#! Link("$(DEVICE):CHECK4.FLNK","$(DEVICE):MODMATCH4")
#! Field("$(DEVICE):CHECK4.INPF",16777215,1,"$(DEVICE):CHECK4.INPF")
#! Field("$(DEVICE):CHECK4.INPP",16777215,1,"$(DEVICE):CHECK4.INPP")
#! Field("$(DEVICE):CHECK4.INPW",16777215,1,"$(DEVICE):CHECK4.INPW")
#! Field("$(DEVICE):CHECK4.Y",16777215,0,"$(DEVICE):CHECK4.Y")
#! Field("$(DEVICE):CHECK4.Z",16777215,0,"$(DEVICE):CHECK4.Z")
#! Field("$(DEVICE):CHECK4.VAL",16777215,1,"$(DEVICE):CHECK4.VAL")
#! Field("$(DEVICE):CHECK4.INPA",16777215,1,"$(DEVICE):CHECK4.INPA")
#! Field("$(DEVICE):CHECK4.INPB",16777215,1,"$(DEVICE):CHECK4.INPB")
#! Link("$(DEVICE):CHECK4.INPB","$(DEVICE):MEASCNT4.VAL")
#! Field("$(DEVICE):CHECK4.Q",16777215,1,"$(DEVICE):CHECK4.Q")
#! Field("$(DEVICE):CHECK4.INPD",16777215,1,"$(DEVICE):CHECK4.INPD")
#! Link("$(DEVICE):CHECK4.INPD","$(DEVICE):DONE4.VAL")
#! Field("$(DEVICE):CHECK4.INPU",16777215,1,"$(DEVICE):CHECK4.INPU")
#! Field("$(DEVICE):CHECK4.INPV",16777215,1,"$(DEVICE):CHECK4.INPV")
#! Field("$(DEVICE):CHECK4.SDIS",16777215,0,"$(DEVICE):CHECK4.SDIS")
#! Link("$(DEVICE):CHECK4.SDIS","$(DEVICE):STATE4.VAL")
#! Field("$(DEVICE):CHECK4.INPI",16777215,1,"$(DEVICE):CHECK4.INPI")
#! Field("$(DEVICE):CHECK4.INPJ",16777215,1,"$(DEVICE):CHECK4.INPJ")
#! Record("$(DEVICE):STATE4",1154,2201,0,1,"$(DEVICE):STATE4")
#! Field("$(DEVICE):STATE4.INPA",16777215,1,"$(DEVICE):STATE4.INPA")
#! Field("$(DEVICE):STATE4.INPB",16777215,1,"$(DEVICE):STATE4.INPB")
#! Link("$(DEVICE):STATE4.INPB","$(DEVICE):DONE4.VAL")
#! Field("$(DEVICE):STATE4.VAL",16777215,1,"$(DEVICE):STATE4.VAL")
#! Record("$(DEVICE):RESETSEQ4",1144,2895,0,0,"$(DEVICE):RESETSEQ4")
#! Field("$(DEVICE):RESETSEQ4.LNK1",16777215,1,"$(DEVICE):RESETSEQ4.LNK1")
#! Link("$(DEVICE):RESETSEQ4.LNK1","$(DEVICE):INIT4.VAL")
#! Field("$(DEVICE):RESETSEQ4.LNK2",16777215,1,"$(DEVICE):RESETSEQ4.LNK2")
#! Link("$(DEVICE):RESETSEQ4.LNK2","$(DEVICE):CHECK4.VAL")
#! Field("$(DEVICE):RESETSEQ4.LNK3",16777215,1,"$(DEVICE):RESETSEQ4.LNK3")
#! Link("$(DEVICE):RESETSEQ4.LNK3","$(DEVICE):CHECK4.Y")
#! Field("$(DEVICE):RESETSEQ4.LNK4",16777215,1,"$(DEVICE):RESETSEQ4.LNK4")
#! Link("$(DEVICE):RESETSEQ4.LNK4","$(DEVICE):CHECK4.Z")
#! Field("$(DEVICE):RESETSEQ4.LNK5",16777215,1,"$(DEVICE):RESETSEQ4.LNK5")
#! Link("$(DEVICE):RESETSEQ4.LNK5","$(DEVICE):MEASCNT4.VAL")
#! Field("$(DEVICE):RESETSEQ4.LNK6",16777215,1,"$(DEVICE):RESETSEQ4.LNK6")
#! Link("$(DEVICE):RESETSEQ4.LNK6","$(DEVICE):DONE4.VAL")
#! Field("$(DEVICE):RESETSEQ4.LNK8",16777215,1,"$(DEVICE):RESETSEQ4.LNK8")
#! Link("$(DEVICE):RESETSEQ4.LNK8","$(DEVICE):INIT4.VAL")
#! Record("$(DEVICE):INIT4",2010,2954,0,1,"$(DEVICE):INIT4")
#! Field("$(DEVICE):INIT4.VAL",16777215,0,"$(DEVICE):INIT4.VAL")
#! Field("$(DEVICE):INIT4.DOL",16777215,0,"$(DEVICE):INIT4.DOL")
#! Link("$(DEVICE):INIT4.DOL","$(DEVICE):CHECK4.VAL")
#! Record("$(DEVICE):MODMATCH4",1938,2448,0,0,"$(DEVICE):MODMATCH4")
#! Field("$(DEVICE):MODMATCH4.DOL",16777215,0,"$(DEVICE):MODMATCH4.DOL")
#! Link("$(DEVICE):MODMATCH4.DOL","$(DEVICE):CHECK4.VAL")
#! Field("$(DEVICE):MODMATCH4.FLNK",16777215,1,"$(DEVICE):MODMATCH4.FLNK")
#! Link("$(DEVICE):MODMATCH4.FLNK","$(DEVICE):MEASCNT4")
#! Field("$(DEVICE):MODMATCH4.VAL",16777215,1,"$(DEVICE):MODMATCH4.VAL")
#! Record("$(DEVICE):DONE4",2530,2306,0,0,"$(DEVICE):DONE4")
#! Field("$(DEVICE):DONE4.FLNK",16777215,0,"$(DEVICE):DONE4.FLNK")
#! Link("$(DEVICE):DONE4.FLNK","$(DEVICE):STATE4")
#! Field("$(DEVICE):DONE4.INPC",16777215,0,"$(DEVICE):DONE4.INPC")
#! Link("$(DEVICE):DONE4.INPC","$(DEVICE):CHECK4.Q")
#! Field("$(DEVICE):DONE4.VAL",16777215,0,"$(DEVICE):DONE4.VAL")
#! Record("$(DEVICE):MEASCNT4",2266,2526,0,0,"$(DEVICE):MEASCNT4")
#! Field("$(DEVICE):MEASCNT4.FLNK",16777215,1,"$(DEVICE):MEASCNT4.FLNK")
#! Link("$(DEVICE):MEASCNT4.FLNK","$(DEVICE):DONE4")
#! Field("$(DEVICE):MEASCNT4.VAL",16777215,0,"$(DEVICE):MEASCNT4.VAL")
#! Field("$(DEVICE):MEASCNT4.INPA",16777215,0,"$(DEVICE):MEASCNT4.INPA")
#! Link("$(DEVICE):MEASCNT4.INPA","$(DEVICE):MODMATCH4.VAL")
#! Field("$(DEVICE):MEASCNT4.INPB",16777215,0,"$(DEVICE):MEASCNT4.INPB")
#! Link("$(DEVICE):MEASCNT4.INPB","$(DEVICE):MEASCNT4.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK5") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):5:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH5")
  field(INPA, "EDEF:$(LOC):5:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT5")
  field(INPD, "$(DEVICE):DONE5")
  field(INPU, "EDEF:$(LOC):5:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):5:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE5")
  field(INPI, "EDEF:$(LOC):5:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):5:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE5") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):5:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE5")
}

record(seq, "$(DEVICE):RESETSEQ5") {
  field(DESC, "EDEF 5 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT5 PP")
  field(LNK2, "$(DEVICE):CHECK5")
  field(LNK3, "$(DEVICE):CHECK5.Y")
  field(LNK4, "$(DEVICE):CHECK5.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT5")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE5")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT5 PP")
}

record(bo, "$(DEVICE):INIT5") {
  field(DOL, "$(DEVICE):CHECK5")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH5") {
  field(FLNK, "$(DEVICE):MEASCNT5")
  field(DOL, "$(DEVICE):CHECK5")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE5") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE5")
  field(INPC, "$(DEVICE):CHECK5.Q")
}

record(calcout, "$(DEVICE):MEASCNT5") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE5")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH5")
  field(INPB, "$(DEVICE):MEASCNT5")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK5",1538,2184,0,0,"$(DEVICE):CHECK5")
#! Field("$(DEVICE):CHECK5.FLNK",16777215,1,"$(DEVICE):CHECK5.FLNK")
#! Link("$(DEVICE):CHECK5.FLNK","$(DEVICE):MODMATCH5")
#! Field("$(DEVICE):CHECK5.INPF",16777215,1,"$(DEVICE):CHECK5.INPF")
#! Field("$(DEVICE):CHECK5.INPP",16777215,1,"$(DEVICE):CHECK5.INPP")
#! Field("$(DEVICE):CHECK5.INPW",16777215,1,"$(DEVICE):CHECK5.INPW")
#! Field("$(DEVICE):CHECK5.Y",16777215,0,"$(DEVICE):CHECK5.Y")
#! Field("$(DEVICE):CHECK5.Z",16777215,0,"$(DEVICE):CHECK5.Z")
#! Field("$(DEVICE):CHECK5.VAL",16777215,1,"$(DEVICE):CHECK5.VAL")
#! Field("$(DEVICE):CHECK5.INPA",16777215,1,"$(DEVICE):CHECK5.INPA")
#! Field("$(DEVICE):CHECK5.INPB",16777215,1,"$(DEVICE):CHECK5.INPB")
#! Link("$(DEVICE):CHECK5.INPB","$(DEVICE):MEASCNT5.VAL")
#! Field("$(DEVICE):CHECK5.Q",16777215,1,"$(DEVICE):CHECK5.Q")
#! Field("$(DEVICE):CHECK5.INPD",16777215,1,"$(DEVICE):CHECK5.INPD")
#! Link("$(DEVICE):CHECK5.INPD","$(DEVICE):DONE5.VAL")
#! Field("$(DEVICE):CHECK5.INPU",16777215,1,"$(DEVICE):CHECK5.INPU")
#! Field("$(DEVICE):CHECK5.INPV",16777215,1,"$(DEVICE):CHECK5.INPV")
#! Field("$(DEVICE):CHECK5.SDIS",16777215,0,"$(DEVICE):CHECK5.SDIS")
#! Link("$(DEVICE):CHECK5.SDIS","$(DEVICE):STATE5.VAL")
#! Field("$(DEVICE):CHECK5.INPI",16777215,1,"$(DEVICE):CHECK5.INPI")
#! Field("$(DEVICE):CHECK5.INPJ",16777215,1,"$(DEVICE):CHECK5.INPJ")
#! Record("$(DEVICE):STATE5",1154,2201,0,1,"$(DEVICE):STATE5")
#! Field("$(DEVICE):STATE5.INPA",16777215,1,"$(DEVICE):STATE5.INPA")
#! Field("$(DEVICE):STATE5.INPB",16777215,1,"$(DEVICE):STATE5.INPB")
#! Link("$(DEVICE):STATE5.INPB","$(DEVICE):DONE5.VAL")
#! Field("$(DEVICE):STATE5.VAL",16777215,1,"$(DEVICE):STATE5.VAL")
#! Record("$(DEVICE):RESETSEQ5",1144,2895,0,0,"$(DEVICE):RESETSEQ5")
#! Field("$(DEVICE):RESETSEQ5.LNK1",16777215,1,"$(DEVICE):RESETSEQ5.LNK1")
#! Link("$(DEVICE):RESETSEQ5.LNK1","$(DEVICE):INIT5.VAL")
#! Field("$(DEVICE):RESETSEQ5.LNK2",16777215,1,"$(DEVICE):RESETSEQ5.LNK2")
#! Link("$(DEVICE):RESETSEQ5.LNK2","$(DEVICE):CHECK5.VAL")
#! Field("$(DEVICE):RESETSEQ5.LNK3",16777215,1,"$(DEVICE):RESETSEQ5.LNK3")
#! Link("$(DEVICE):RESETSEQ5.LNK3","$(DEVICE):CHECK5.Y")
#! Field("$(DEVICE):RESETSEQ5.LNK4",16777215,1,"$(DEVICE):RESETSEQ5.LNK4")
#! Link("$(DEVICE):RESETSEQ5.LNK4","$(DEVICE):CHECK5.Z")
#! Field("$(DEVICE):RESETSEQ5.LNK5",16777215,1,"$(DEVICE):RESETSEQ5.LNK5")
#! Link("$(DEVICE):RESETSEQ5.LNK5","$(DEVICE):MEASCNT5.VAL")
#! Field("$(DEVICE):RESETSEQ5.LNK6",16777215,1,"$(DEVICE):RESETSEQ5.LNK6")
#! Link("$(DEVICE):RESETSEQ5.LNK6","$(DEVICE):DONE5.VAL")
#! Field("$(DEVICE):RESETSEQ5.LNK8",16777215,1,"$(DEVICE):RESETSEQ5.LNK8")
#! Link("$(DEVICE):RESETSEQ5.LNK8","$(DEVICE):INIT5.VAL")
#! Record("$(DEVICE):INIT5",2010,2954,0,1,"$(DEVICE):INIT5")
#! Field("$(DEVICE):INIT5.VAL",16777215,0,"$(DEVICE):INIT5.VAL")
#! Field("$(DEVICE):INIT5.DOL",16777215,0,"$(DEVICE):INIT5.DOL")
#! Link("$(DEVICE):INIT5.DOL","$(DEVICE):CHECK5.VAL")
#! Record("$(DEVICE):MODMATCH5",1938,2448,0,0,"$(DEVICE):MODMATCH5")
#! Field("$(DEVICE):MODMATCH5.DOL",16777215,0,"$(DEVICE):MODMATCH5.DOL")
#! Link("$(DEVICE):MODMATCH5.DOL","$(DEVICE):CHECK5.VAL")
#! Field("$(DEVICE):MODMATCH5.FLNK",16777215,1,"$(DEVICE):MODMATCH5.FLNK")
#! Link("$(DEVICE):MODMATCH5.FLNK","$(DEVICE):MEASCNT5")
#! Field("$(DEVICE):MODMATCH5.VAL",16777215,1,"$(DEVICE):MODMATCH5.VAL")
#! Record("$(DEVICE):DONE5",2530,2306,0,0,"$(DEVICE):DONE5")
#! Field("$(DEVICE):DONE5.FLNK",16777215,0,"$(DEVICE):DONE5.FLNK")
#! Link("$(DEVICE):DONE5.FLNK","$(DEVICE):STATE5")
#! Field("$(DEVICE):DONE5.INPC",16777215,0,"$(DEVICE):DONE5.INPC")
#! Link("$(DEVICE):DONE5.INPC","$(DEVICE):CHECK5.Q")
#! Field("$(DEVICE):DONE5.VAL",16777215,0,"$(DEVICE):DONE5.VAL")
#! Record("$(DEVICE):MEASCNT5",2266,2526,0,0,"$(DEVICE):MEASCNT5")
#! Field("$(DEVICE):MEASCNT5.FLNK",16777215,1,"$(DEVICE):MEASCNT5.FLNK")
#! Link("$(DEVICE):MEASCNT5.FLNK","$(DEVICE):DONE5")
#! Field("$(DEVICE):MEASCNT5.VAL",16777215,0,"$(DEVICE):MEASCNT5.VAL")
#! Field("$(DEVICE):MEASCNT5.INPA",16777215,0,"$(DEVICE):MEASCNT5.INPA")
#! Link("$(DEVICE):MEASCNT5.INPA","$(DEVICE):MODMATCH5.VAL")
#! Field("$(DEVICE):MEASCNT5.INPB",16777215,0,"$(DEVICE):MEASCNT5.INPB")
#! Link("$(DEVICE):MEASCNT5.INPB","$(DEVICE):MEASCNT5.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK6") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):6:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH6")
  field(INPA, "EDEF:$(LOC):6:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT6")
  field(INPD, "$(DEVICE):DONE6")
  field(INPU, "EDEF:$(LOC):6:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):6:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE6")
  field(INPI, "EDEF:$(LOC):6:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):6:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE6") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):6:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE6")
}

record(seq, "$(DEVICE):RESETSEQ6") {
  field(DESC, "EDEF 6 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT6 PP")
  field(LNK2, "$(DEVICE):CHECK6")
  field(LNK3, "$(DEVICE):CHECK6.Y")
  field(LNK4, "$(DEVICE):CHECK6.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT6")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE6")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT6 PP")
}

record(bo, "$(DEVICE):INIT6") {
  field(DOL, "$(DEVICE):CHECK6")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH6") {
  field(FLNK, "$(DEVICE):MEASCNT6")
  field(DOL, "$(DEVICE):CHECK6")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE6") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE6")
  field(INPC, "$(DEVICE):CHECK6.Q")
}

record(calcout, "$(DEVICE):MEASCNT6") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE6")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH6")
  field(INPB, "$(DEVICE):MEASCNT6")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK6",1538,2184,0,0,"$(DEVICE):CHECK6")
#! Field("$(DEVICE):CHECK6.FLNK",16777215,1,"$(DEVICE):CHECK6.FLNK")
#! Link("$(DEVICE):CHECK6.FLNK","$(DEVICE):MODMATCH6")
#! Field("$(DEVICE):CHECK6.INPF",16777215,1,"$(DEVICE):CHECK6.INPF")
#! Field("$(DEVICE):CHECK6.INPP",16777215,1,"$(DEVICE):CHECK6.INPP")
#! Field("$(DEVICE):CHECK6.INPW",16777215,1,"$(DEVICE):CHECK6.INPW")
#! Field("$(DEVICE):CHECK6.Y",16777215,0,"$(DEVICE):CHECK6.Y")
#! Field("$(DEVICE):CHECK6.Z",16777215,0,"$(DEVICE):CHECK6.Z")
#! Field("$(DEVICE):CHECK6.VAL",16777215,1,"$(DEVICE):CHECK6.VAL")
#! Field("$(DEVICE):CHECK6.INPA",16777215,1,"$(DEVICE):CHECK6.INPA")
#! Field("$(DEVICE):CHECK6.INPB",16777215,1,"$(DEVICE):CHECK6.INPB")
#! Link("$(DEVICE):CHECK6.INPB","$(DEVICE):MEASCNT6.VAL")
#! Field("$(DEVICE):CHECK6.Q",16777215,1,"$(DEVICE):CHECK6.Q")
#! Field("$(DEVICE):CHECK6.INPD",16777215,1,"$(DEVICE):CHECK6.INPD")
#! Link("$(DEVICE):CHECK6.INPD","$(DEVICE):DONE6.VAL")
#! Field("$(DEVICE):CHECK6.INPU",16777215,1,"$(DEVICE):CHECK6.INPU")
#! Field("$(DEVICE):CHECK6.INPV",16777215,1,"$(DEVICE):CHECK6.INPV")
#! Field("$(DEVICE):CHECK6.SDIS",16777215,0,"$(DEVICE):CHECK6.SDIS")
#! Link("$(DEVICE):CHECK6.SDIS","$(DEVICE):STATE6.VAL")
#! Field("$(DEVICE):CHECK6.INPI",16777215,1,"$(DEVICE):CHECK6.INPI")
#! Field("$(DEVICE):CHECK6.INPJ",16777215,1,"$(DEVICE):CHECK6.INPJ")
#! Record("$(DEVICE):STATE6",1154,2201,0,1,"$(DEVICE):STATE6")
#! Field("$(DEVICE):STATE6.INPA",16777215,1,"$(DEVICE):STATE6.INPA")
#! Field("$(DEVICE):STATE6.INPB",16777215,1,"$(DEVICE):STATE6.INPB")
#! Link("$(DEVICE):STATE6.INPB","$(DEVICE):DONE6.VAL")
#! Field("$(DEVICE):STATE6.VAL",16777215,1,"$(DEVICE):STATE6.VAL")
#! Record("$(DEVICE):RESETSEQ6",1144,2895,0,0,"$(DEVICE):RESETSEQ6")
#! Field("$(DEVICE):RESETSEQ6.LNK1",16777215,1,"$(DEVICE):RESETSEQ6.LNK1")
#! Link("$(DEVICE):RESETSEQ6.LNK1","$(DEVICE):INIT6.VAL")
#! Field("$(DEVICE):RESETSEQ6.LNK2",16777215,1,"$(DEVICE):RESETSEQ6.LNK2")
#! Link("$(DEVICE):RESETSEQ6.LNK2","$(DEVICE):CHECK6.VAL")
#! Field("$(DEVICE):RESETSEQ6.LNK3",16777215,1,"$(DEVICE):RESETSEQ6.LNK3")
#! Link("$(DEVICE):RESETSEQ6.LNK3","$(DEVICE):CHECK6.Y")
#! Field("$(DEVICE):RESETSEQ6.LNK4",16777215,1,"$(DEVICE):RESETSEQ6.LNK4")
#! Link("$(DEVICE):RESETSEQ6.LNK4","$(DEVICE):CHECK6.Z")
#! Field("$(DEVICE):RESETSEQ6.LNK5",16777215,1,"$(DEVICE):RESETSEQ6.LNK5")
#! Link("$(DEVICE):RESETSEQ6.LNK5","$(DEVICE):MEASCNT6.VAL")
#! Field("$(DEVICE):RESETSEQ6.LNK6",16777215,1,"$(DEVICE):RESETSEQ6.LNK6")
#! Link("$(DEVICE):RESETSEQ6.LNK6","$(DEVICE):DONE6.VAL")
#! Field("$(DEVICE):RESETSEQ6.LNK8",16777215,1,"$(DEVICE):RESETSEQ6.LNK8")
#! Link("$(DEVICE):RESETSEQ6.LNK8","$(DEVICE):INIT6.VAL")
#! Record("$(DEVICE):INIT6",2010,2954,0,1,"$(DEVICE):INIT6")
#! Field("$(DEVICE):INIT6.VAL",16777215,0,"$(DEVICE):INIT6.VAL")
#! Field("$(DEVICE):INIT6.DOL",16777215,0,"$(DEVICE):INIT6.DOL")
#! Link("$(DEVICE):INIT6.DOL","$(DEVICE):CHECK6.VAL")
#! Record("$(DEVICE):MODMATCH6",1938,2448,0,0,"$(DEVICE):MODMATCH6")
#! Field("$(DEVICE):MODMATCH6.DOL",16777215,0,"$(DEVICE):MODMATCH6.DOL")
#! Link("$(DEVICE):MODMATCH6.DOL","$(DEVICE):CHECK6.VAL")
#! Field("$(DEVICE):MODMATCH6.FLNK",16777215,1,"$(DEVICE):MODMATCH6.FLNK")
#! Link("$(DEVICE):MODMATCH6.FLNK","$(DEVICE):MEASCNT6")
#! Field("$(DEVICE):MODMATCH6.VAL",16777215,1,"$(DEVICE):MODMATCH6.VAL")
#! Record("$(DEVICE):DONE6",2530,2306,0,0,"$(DEVICE):DONE6")
#! Field("$(DEVICE):DONE6.FLNK",16777215,0,"$(DEVICE):DONE6.FLNK")
#! Link("$(DEVICE):DONE6.FLNK","$(DEVICE):STATE6")
#! Field("$(DEVICE):DONE6.INPC",16777215,0,"$(DEVICE):DONE6.INPC")
#! Link("$(DEVICE):DONE6.INPC","$(DEVICE):CHECK6.Q")
#! Field("$(DEVICE):DONE6.VAL",16777215,0,"$(DEVICE):DONE6.VAL")
#! Record("$(DEVICE):MEASCNT6",2266,2526,0,0,"$(DEVICE):MEASCNT6")
#! Field("$(DEVICE):MEASCNT6.FLNK",16777215,1,"$(DEVICE):MEASCNT6.FLNK")
#! Link("$(DEVICE):MEASCNT6.FLNK","$(DEVICE):DONE6")
#! Field("$(DEVICE):MEASCNT6.VAL",16777215,0,"$(DEVICE):MEASCNT6.VAL")
#! Field("$(DEVICE):MEASCNT6.INPA",16777215,0,"$(DEVICE):MEASCNT6.INPA")
#! Link("$(DEVICE):MEASCNT6.INPA","$(DEVICE):MODMATCH6.VAL")
#! Field("$(DEVICE):MEASCNT6.INPB",16777215,0,"$(DEVICE):MEASCNT6.INPB")
#! Link("$(DEVICE):MEASCNT6.INPB","$(DEVICE):MEASCNT6.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK7") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):7:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH7")
  field(INPA, "EDEF:$(LOC):7:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT7")
  field(INPD, "$(DEVICE):DONE7")
  field(INPU, "EDEF:$(LOC):7:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):7:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE7")
  field(INPI, "EDEF:$(LOC):7:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):7:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE7") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):7:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE7")
}

record(seq, "$(DEVICE):RESETSEQ7") {
  field(DESC, "EDEF 7 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT7 PP")
  field(LNK2, "$(DEVICE):CHECK7")
  field(LNK3, "$(DEVICE):CHECK7.Y")
  field(LNK4, "$(DEVICE):CHECK7.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT7")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE7")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT7 PP")
}

record(bo, "$(DEVICE):INIT7") {
  field(DOL, "$(DEVICE):CHECK7")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH7") {
  field(FLNK, "$(DEVICE):MEASCNT7")
  field(DOL, "$(DEVICE):CHECK7")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE7") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE7")
  field(INPC, "$(DEVICE):CHECK7.Q")
}

record(calcout, "$(DEVICE):MEASCNT7") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE7")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH7")
  field(INPB, "$(DEVICE):MEASCNT7")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK7",1538,2184,0,0,"$(DEVICE):CHECK7")
#! Field("$(DEVICE):CHECK7.FLNK",16777215,1,"$(DEVICE):CHECK7.FLNK")
#! Link("$(DEVICE):CHECK7.FLNK","$(DEVICE):MODMATCH7")
#! Field("$(DEVICE):CHECK7.INPF",16777215,1,"$(DEVICE):CHECK7.INPF")
#! Field("$(DEVICE):CHECK7.INPP",16777215,1,"$(DEVICE):CHECK7.INPP")
#! Field("$(DEVICE):CHECK7.INPW",16777215,1,"$(DEVICE):CHECK7.INPW")
#! Field("$(DEVICE):CHECK7.Y",16777215,0,"$(DEVICE):CHECK7.Y")
#! Field("$(DEVICE):CHECK7.Z",16777215,0,"$(DEVICE):CHECK7.Z")
#! Field("$(DEVICE):CHECK7.VAL",16777215,1,"$(DEVICE):CHECK7.VAL")
#! Field("$(DEVICE):CHECK7.INPA",16777215,1,"$(DEVICE):CHECK7.INPA")
#! Field("$(DEVICE):CHECK7.INPB",16777215,1,"$(DEVICE):CHECK7.INPB")
#! Link("$(DEVICE):CHECK7.INPB","$(DEVICE):MEASCNT7.VAL")
#! Field("$(DEVICE):CHECK7.Q",16777215,1,"$(DEVICE):CHECK7.Q")
#! Field("$(DEVICE):CHECK7.INPD",16777215,1,"$(DEVICE):CHECK7.INPD")
#! Link("$(DEVICE):CHECK7.INPD","$(DEVICE):DONE7.VAL")
#! Field("$(DEVICE):CHECK7.INPU",16777215,1,"$(DEVICE):CHECK7.INPU")
#! Field("$(DEVICE):CHECK7.INPV",16777215,1,"$(DEVICE):CHECK7.INPV")
#! Field("$(DEVICE):CHECK7.SDIS",16777215,0,"$(DEVICE):CHECK7.SDIS")
#! Link("$(DEVICE):CHECK7.SDIS","$(DEVICE):STATE7.VAL")
#! Field("$(DEVICE):CHECK7.INPI",16777215,1,"$(DEVICE):CHECK7.INPI")
#! Field("$(DEVICE):CHECK7.INPJ",16777215,1,"$(DEVICE):CHECK7.INPJ")
#! Record("$(DEVICE):STATE7",1154,2201,0,1,"$(DEVICE):STATE7")
#! Field("$(DEVICE):STATE7.INPA",16777215,1,"$(DEVICE):STATE7.INPA")
#! Field("$(DEVICE):STATE7.INPB",16777215,1,"$(DEVICE):STATE7.INPB")
#! Link("$(DEVICE):STATE7.INPB","$(DEVICE):DONE7.VAL")
#! Field("$(DEVICE):STATE7.VAL",16777215,1,"$(DEVICE):STATE7.VAL")
#! Record("$(DEVICE):RESETSEQ7",1144,2895,0,0,"$(DEVICE):RESETSEQ7")
#! Field("$(DEVICE):RESETSEQ7.LNK1",16777215,1,"$(DEVICE):RESETSEQ7.LNK1")
#! Link("$(DEVICE):RESETSEQ7.LNK1","$(DEVICE):INIT7.VAL")
#! Field("$(DEVICE):RESETSEQ7.LNK2",16777215,1,"$(DEVICE):RESETSEQ7.LNK2")
#! Link("$(DEVICE):RESETSEQ7.LNK2","$(DEVICE):CHECK7.VAL")
#! Field("$(DEVICE):RESETSEQ7.LNK3",16777215,1,"$(DEVICE):RESETSEQ7.LNK3")
#! Link("$(DEVICE):RESETSEQ7.LNK3","$(DEVICE):CHECK7.Y")
#! Field("$(DEVICE):RESETSEQ7.LNK4",16777215,1,"$(DEVICE):RESETSEQ7.LNK4")
#! Link("$(DEVICE):RESETSEQ7.LNK4","$(DEVICE):CHECK7.Z")
#! Field("$(DEVICE):RESETSEQ7.LNK5",16777215,1,"$(DEVICE):RESETSEQ7.LNK5")
#! Link("$(DEVICE):RESETSEQ7.LNK5","$(DEVICE):MEASCNT7.VAL")
#! Field("$(DEVICE):RESETSEQ7.LNK6",16777215,1,"$(DEVICE):RESETSEQ7.LNK6")
#! Link("$(DEVICE):RESETSEQ7.LNK6","$(DEVICE):DONE7.VAL")
#! Field("$(DEVICE):RESETSEQ7.LNK8",16777215,1,"$(DEVICE):RESETSEQ7.LNK8")
#! Link("$(DEVICE):RESETSEQ7.LNK8","$(DEVICE):INIT7.VAL")
#! Record("$(DEVICE):INIT7",2010,2954,0,1,"$(DEVICE):INIT7")
#! Field("$(DEVICE):INIT7.VAL",16777215,0,"$(DEVICE):INIT7.VAL")
#! Field("$(DEVICE):INIT7.DOL",16777215,0,"$(DEVICE):INIT7.DOL")
#! Link("$(DEVICE):INIT7.DOL","$(DEVICE):CHECK7.VAL")
#! Record("$(DEVICE):MODMATCH7",1938,2448,0,0,"$(DEVICE):MODMATCH7")
#! Field("$(DEVICE):MODMATCH7.DOL",16777215,0,"$(DEVICE):MODMATCH7.DOL")
#! Link("$(DEVICE):MODMATCH7.DOL","$(DEVICE):CHECK7.VAL")
#! Field("$(DEVICE):MODMATCH7.FLNK",16777215,1,"$(DEVICE):MODMATCH7.FLNK")
#! Link("$(DEVICE):MODMATCH7.FLNK","$(DEVICE):MEASCNT7")
#! Field("$(DEVICE):MODMATCH7.VAL",16777215,1,"$(DEVICE):MODMATCH7.VAL")
#! Record("$(DEVICE):DONE7",2530,2306,0,0,"$(DEVICE):DONE7")
#! Field("$(DEVICE):DONE7.FLNK",16777215,0,"$(DEVICE):DONE7.FLNK")
#! Link("$(DEVICE):DONE7.FLNK","$(DEVICE):STATE7")
#! Field("$(DEVICE):DONE7.INPC",16777215,0,"$(DEVICE):DONE7.INPC")
#! Link("$(DEVICE):DONE7.INPC","$(DEVICE):CHECK7.Q")
#! Field("$(DEVICE):DONE7.VAL",16777215,0,"$(DEVICE):DONE7.VAL")
#! Record("$(DEVICE):MEASCNT7",2266,2526,0,0,"$(DEVICE):MEASCNT7")
#! Field("$(DEVICE):MEASCNT7.FLNK",16777215,1,"$(DEVICE):MEASCNT7.FLNK")
#! Link("$(DEVICE):MEASCNT7.FLNK","$(DEVICE):DONE7")
#! Field("$(DEVICE):MEASCNT7.VAL",16777215,0,"$(DEVICE):MEASCNT7.VAL")
#! Field("$(DEVICE):MEASCNT7.INPA",16777215,0,"$(DEVICE):MEASCNT7.INPA")
#! Link("$(DEVICE):MEASCNT7.INPA","$(DEVICE):MODMATCH7.VAL")
#! Field("$(DEVICE):MEASCNT7.INPB",16777215,0,"$(DEVICE):MEASCNT7.INPB")
#! Link("$(DEVICE):MEASCNT7.INPB","$(DEVICE):MEASCNT7.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK8") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):8:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH8")
  field(INPA, "EDEF:$(LOC):8:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT8")
  field(INPD, "$(DEVICE):DONE8")
  field(INPU, "EDEF:$(LOC):8:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):8:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE8")
  field(INPI, "EDEF:$(LOC):8:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):8:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE8") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):8:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE8")
}

record(seq, "$(DEVICE):RESETSEQ8") {
  field(DESC, "EDEF 8 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT8 PP")
  field(LNK2, "$(DEVICE):CHECK8")
  field(LNK3, "$(DEVICE):CHECK8.Y")
  field(LNK4, "$(DEVICE):CHECK8.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT8")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE8")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT8 PP")
}

record(bo, "$(DEVICE):INIT8") {
  field(DOL, "$(DEVICE):CHECK8")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH8") {
  field(FLNK, "$(DEVICE):MEASCNT8")
  field(DOL, "$(DEVICE):CHECK8")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE8") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE8")
  field(INPC, "$(DEVICE):CHECK8.Q")
}

record(calcout, "$(DEVICE):MEASCNT8") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE8")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH8")
  field(INPB, "$(DEVICE):MEASCNT8")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK8",1538,2184,0,0,"$(DEVICE):CHECK8")
#! Field("$(DEVICE):CHECK8.FLNK",16777215,1,"$(DEVICE):CHECK8.FLNK")
#! Link("$(DEVICE):CHECK8.FLNK","$(DEVICE):MODMATCH8")
#! Field("$(DEVICE):CHECK8.INPF",16777215,1,"$(DEVICE):CHECK8.INPF")
#! Field("$(DEVICE):CHECK8.INPP",16777215,1,"$(DEVICE):CHECK8.INPP")
#! Field("$(DEVICE):CHECK8.INPW",16777215,1,"$(DEVICE):CHECK8.INPW")
#! Field("$(DEVICE):CHECK8.Y",16777215,0,"$(DEVICE):CHECK8.Y")
#! Field("$(DEVICE):CHECK8.Z",16777215,0,"$(DEVICE):CHECK8.Z")
#! Field("$(DEVICE):CHECK8.VAL",16777215,1,"$(DEVICE):CHECK8.VAL")
#! Field("$(DEVICE):CHECK8.INPA",16777215,1,"$(DEVICE):CHECK8.INPA")
#! Field("$(DEVICE):CHECK8.INPB",16777215,1,"$(DEVICE):CHECK8.INPB")
#! Link("$(DEVICE):CHECK8.INPB","$(DEVICE):MEASCNT8.VAL")
#! Field("$(DEVICE):CHECK8.Q",16777215,1,"$(DEVICE):CHECK8.Q")
#! Field("$(DEVICE):CHECK8.INPD",16777215,1,"$(DEVICE):CHECK8.INPD")
#! Link("$(DEVICE):CHECK8.INPD","$(DEVICE):DONE8.VAL")
#! Field("$(DEVICE):CHECK8.INPU",16777215,1,"$(DEVICE):CHECK8.INPU")
#! Field("$(DEVICE):CHECK8.INPV",16777215,1,"$(DEVICE):CHECK8.INPV")
#! Field("$(DEVICE):CHECK8.SDIS",16777215,0,"$(DEVICE):CHECK8.SDIS")
#! Link("$(DEVICE):CHECK8.SDIS","$(DEVICE):STATE8.VAL")
#! Field("$(DEVICE):CHECK8.INPI",16777215,1,"$(DEVICE):CHECK8.INPI")
#! Field("$(DEVICE):CHECK8.INPJ",16777215,1,"$(DEVICE):CHECK8.INPJ")
#! Record("$(DEVICE):STATE8",1154,2201,0,1,"$(DEVICE):STATE8")
#! Field("$(DEVICE):STATE8.INPA",16777215,1,"$(DEVICE):STATE8.INPA")
#! Field("$(DEVICE):STATE8.INPB",16777215,1,"$(DEVICE):STATE8.INPB")
#! Link("$(DEVICE):STATE8.INPB","$(DEVICE):DONE8.VAL")
#! Field("$(DEVICE):STATE8.VAL",16777215,1,"$(DEVICE):STATE8.VAL")
#! Record("$(DEVICE):RESETSEQ8",1144,2895,0,0,"$(DEVICE):RESETSEQ8")
#! Field("$(DEVICE):RESETSEQ8.LNK1",16777215,1,"$(DEVICE):RESETSEQ8.LNK1")
#! Link("$(DEVICE):RESETSEQ8.LNK1","$(DEVICE):INIT8.VAL")
#! Field("$(DEVICE):RESETSEQ8.LNK2",16777215,1,"$(DEVICE):RESETSEQ8.LNK2")
#! Link("$(DEVICE):RESETSEQ8.LNK2","$(DEVICE):CHECK8.VAL")
#! Field("$(DEVICE):RESETSEQ8.LNK3",16777215,1,"$(DEVICE):RESETSEQ8.LNK3")
#! Link("$(DEVICE):RESETSEQ8.LNK3","$(DEVICE):CHECK8.Y")
#! Field("$(DEVICE):RESETSEQ8.LNK4",16777215,1,"$(DEVICE):RESETSEQ8.LNK4")
#! Link("$(DEVICE):RESETSEQ8.LNK4","$(DEVICE):CHECK8.Z")
#! Field("$(DEVICE):RESETSEQ8.LNK5",16777215,1,"$(DEVICE):RESETSEQ8.LNK5")
#! Link("$(DEVICE):RESETSEQ8.LNK5","$(DEVICE):MEASCNT8.VAL")
#! Field("$(DEVICE):RESETSEQ8.LNK6",16777215,1,"$(DEVICE):RESETSEQ8.LNK6")
#! Link("$(DEVICE):RESETSEQ8.LNK6","$(DEVICE):DONE8.VAL")
#! Field("$(DEVICE):RESETSEQ8.LNK8",16777215,1,"$(DEVICE):RESETSEQ8.LNK8")
#! Link("$(DEVICE):RESETSEQ8.LNK8","$(DEVICE):INIT8.VAL")
#! Record("$(DEVICE):INIT8",2010,2954,0,1,"$(DEVICE):INIT8")
#! Field("$(DEVICE):INIT8.VAL",16777215,0,"$(DEVICE):INIT8.VAL")
#! Field("$(DEVICE):INIT8.DOL",16777215,0,"$(DEVICE):INIT8.DOL")
#! Link("$(DEVICE):INIT8.DOL","$(DEVICE):CHECK8.VAL")
#! Record("$(DEVICE):MODMATCH8",1938,2448,0,0,"$(DEVICE):MODMATCH8")
#! Field("$(DEVICE):MODMATCH8.DOL",16777215,0,"$(DEVICE):MODMATCH8.DOL")
#! Link("$(DEVICE):MODMATCH8.DOL","$(DEVICE):CHECK8.VAL")
#! Field("$(DEVICE):MODMATCH8.FLNK",16777215,1,"$(DEVICE):MODMATCH8.FLNK")
#! Link("$(DEVICE):MODMATCH8.FLNK","$(DEVICE):MEASCNT8")
#! Field("$(DEVICE):MODMATCH8.VAL",16777215,1,"$(DEVICE):MODMATCH8.VAL")
#! Record("$(DEVICE):DONE8",2530,2306,0,0,"$(DEVICE):DONE8")
#! Field("$(DEVICE):DONE8.FLNK",16777215,0,"$(DEVICE):DONE8.FLNK")
#! Link("$(DEVICE):DONE8.FLNK","$(DEVICE):STATE8")
#! Field("$(DEVICE):DONE8.INPC",16777215,0,"$(DEVICE):DONE8.INPC")
#! Link("$(DEVICE):DONE8.INPC","$(DEVICE):CHECK8.Q")
#! Field("$(DEVICE):DONE8.VAL",16777215,0,"$(DEVICE):DONE8.VAL")
#! Record("$(DEVICE):MEASCNT8",2266,2526,0,0,"$(DEVICE):MEASCNT8")
#! Field("$(DEVICE):MEASCNT8.FLNK",16777215,1,"$(DEVICE):MEASCNT8.FLNK")
#! Link("$(DEVICE):MEASCNT8.FLNK","$(DEVICE):DONE8")
#! Field("$(DEVICE):MEASCNT8.VAL",16777215,0,"$(DEVICE):MEASCNT8.VAL")
#! Field("$(DEVICE):MEASCNT8.INPA",16777215,0,"$(DEVICE):MEASCNT8.INPA")
#! Link("$(DEVICE):MEASCNT8.INPA","$(DEVICE):MODMATCH8.VAL")
#! Field("$(DEVICE):MEASCNT8.INPB",16777215,0,"$(DEVICE):MEASCNT8.INPB")
#! Link("$(DEVICE):MEASCNT8.INPB","$(DEVICE):MEASCNT8.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK9") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):9:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH9")
  field(INPA, "EDEF:$(LOC):9:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT9")
  field(INPD, "$(DEVICE):DONE9")
  field(INPU, "EDEF:$(LOC):9:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):9:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE9")
  field(INPI, "EDEF:$(LOC):9:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):9:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE9") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):9:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE9")
}

record(seq, "$(DEVICE):RESETSEQ9") {
  field(DESC, "EDEF 9 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT9 PP")
  field(LNK2, "$(DEVICE):CHECK9")
  field(LNK3, "$(DEVICE):CHECK9.Y")
  field(LNK4, "$(DEVICE):CHECK9.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT9")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE9")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT9 PP")
}

record(bo, "$(DEVICE):INIT9") {
  field(DOL, "$(DEVICE):CHECK9")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH9") {
  field(FLNK, "$(DEVICE):MEASCNT9")
  field(DOL, "$(DEVICE):CHECK9")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE9") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE9")
  field(INPC, "$(DEVICE):CHECK9.Q")
}

record(calcout, "$(DEVICE):MEASCNT9") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE9")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH9")
  field(INPB, "$(DEVICE):MEASCNT9")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK9",1538,2184,0,0,"$(DEVICE):CHECK9")
#! Field("$(DEVICE):CHECK9.FLNK",16777215,1,"$(DEVICE):CHECK9.FLNK")
#! Link("$(DEVICE):CHECK9.FLNK","$(DEVICE):MODMATCH9")
#! Field("$(DEVICE):CHECK9.INPF",16777215,1,"$(DEVICE):CHECK9.INPF")
#! Field("$(DEVICE):CHECK9.INPP",16777215,1,"$(DEVICE):CHECK9.INPP")
#! Field("$(DEVICE):CHECK9.INPW",16777215,1,"$(DEVICE):CHECK9.INPW")
#! Field("$(DEVICE):CHECK9.Y",16777215,0,"$(DEVICE):CHECK9.Y")
#! Field("$(DEVICE):CHECK9.Z",16777215,0,"$(DEVICE):CHECK9.Z")
#! Field("$(DEVICE):CHECK9.VAL",16777215,1,"$(DEVICE):CHECK9.VAL")
#! Field("$(DEVICE):CHECK9.INPA",16777215,1,"$(DEVICE):CHECK9.INPA")
#! Field("$(DEVICE):CHECK9.INPB",16777215,1,"$(DEVICE):CHECK9.INPB")
#! Link("$(DEVICE):CHECK9.INPB","$(DEVICE):MEASCNT9.VAL")
#! Field("$(DEVICE):CHECK9.Q",16777215,1,"$(DEVICE):CHECK9.Q")
#! Field("$(DEVICE):CHECK9.INPD",16777215,1,"$(DEVICE):CHECK9.INPD")
#! Link("$(DEVICE):CHECK9.INPD","$(DEVICE):DONE9.VAL")
#! Field("$(DEVICE):CHECK9.INPU",16777215,1,"$(DEVICE):CHECK9.INPU")
#! Field("$(DEVICE):CHECK9.INPV",16777215,1,"$(DEVICE):CHECK9.INPV")
#! Field("$(DEVICE):CHECK9.SDIS",16777215,0,"$(DEVICE):CHECK9.SDIS")
#! Link("$(DEVICE):CHECK9.SDIS","$(DEVICE):STATE9.VAL")
#! Field("$(DEVICE):CHECK9.INPI",16777215,1,"$(DEVICE):CHECK9.INPI")
#! Field("$(DEVICE):CHECK9.INPJ",16777215,1,"$(DEVICE):CHECK9.INPJ")
#! Record("$(DEVICE):STATE9",1154,2201,0,1,"$(DEVICE):STATE9")
#! Field("$(DEVICE):STATE9.INPA",16777215,1,"$(DEVICE):STATE9.INPA")
#! Field("$(DEVICE):STATE9.INPB",16777215,1,"$(DEVICE):STATE9.INPB")
#! Link("$(DEVICE):STATE9.INPB","$(DEVICE):DONE9.VAL")
#! Field("$(DEVICE):STATE9.VAL",16777215,1,"$(DEVICE):STATE9.VAL")
#! Record("$(DEVICE):RESETSEQ9",1144,2895,0,0,"$(DEVICE):RESETSEQ9")
#! Field("$(DEVICE):RESETSEQ9.LNK1",16777215,1,"$(DEVICE):RESETSEQ9.LNK1")
#! Link("$(DEVICE):RESETSEQ9.LNK1","$(DEVICE):INIT9.VAL")
#! Field("$(DEVICE):RESETSEQ9.LNK2",16777215,1,"$(DEVICE):RESETSEQ9.LNK2")
#! Link("$(DEVICE):RESETSEQ9.LNK2","$(DEVICE):CHECK9.VAL")
#! Field("$(DEVICE):RESETSEQ9.LNK3",16777215,1,"$(DEVICE):RESETSEQ9.LNK3")
#! Link("$(DEVICE):RESETSEQ9.LNK3","$(DEVICE):CHECK9.Y")
#! Field("$(DEVICE):RESETSEQ9.LNK4",16777215,1,"$(DEVICE):RESETSEQ9.LNK4")
#! Link("$(DEVICE):RESETSEQ9.LNK4","$(DEVICE):CHECK9.Z")
#! Field("$(DEVICE):RESETSEQ9.LNK5",16777215,1,"$(DEVICE):RESETSEQ9.LNK5")
#! Link("$(DEVICE):RESETSEQ9.LNK5","$(DEVICE):MEASCNT9.VAL")
#! Field("$(DEVICE):RESETSEQ9.LNK6",16777215,1,"$(DEVICE):RESETSEQ9.LNK6")
#! Link("$(DEVICE):RESETSEQ9.LNK6","$(DEVICE):DONE9.VAL")
#! Field("$(DEVICE):RESETSEQ9.LNK8",16777215,1,"$(DEVICE):RESETSEQ9.LNK8")
#! Link("$(DEVICE):RESETSEQ9.LNK8","$(DEVICE):INIT9.VAL")
#! Record("$(DEVICE):INIT9",2010,2954,0,1,"$(DEVICE):INIT9")
#! Field("$(DEVICE):INIT9.VAL",16777215,0,"$(DEVICE):INIT9.VAL")
#! Field("$(DEVICE):INIT9.DOL",16777215,0,"$(DEVICE):INIT9.DOL")
#! Link("$(DEVICE):INIT9.DOL","$(DEVICE):CHECK9.VAL")
#! Record("$(DEVICE):MODMATCH9",1938,2448,0,0,"$(DEVICE):MODMATCH9")
#! Field("$(DEVICE):MODMATCH9.DOL",16777215,0,"$(DEVICE):MODMATCH9.DOL")
#! Link("$(DEVICE):MODMATCH9.DOL","$(DEVICE):CHECK9.VAL")
#! Field("$(DEVICE):MODMATCH9.FLNK",16777215,1,"$(DEVICE):MODMATCH9.FLNK")
#! Link("$(DEVICE):MODMATCH9.FLNK","$(DEVICE):MEASCNT9")
#! Field("$(DEVICE):MODMATCH9.VAL",16777215,1,"$(DEVICE):MODMATCH9.VAL")
#! Record("$(DEVICE):DONE9",2530,2306,0,0,"$(DEVICE):DONE9")
#! Field("$(DEVICE):DONE9.FLNK",16777215,0,"$(DEVICE):DONE9.FLNK")
#! Link("$(DEVICE):DONE9.FLNK","$(DEVICE):STATE9")
#! Field("$(DEVICE):DONE9.INPC",16777215,0,"$(DEVICE):DONE9.INPC")
#! Link("$(DEVICE):DONE9.INPC","$(DEVICE):CHECK9.Q")
#! Field("$(DEVICE):DONE9.VAL",16777215,0,"$(DEVICE):DONE9.VAL")
#! Record("$(DEVICE):MEASCNT9",2266,2526,0,0,"$(DEVICE):MEASCNT9")
#! Field("$(DEVICE):MEASCNT9.FLNK",16777215,1,"$(DEVICE):MEASCNT9.FLNK")
#! Link("$(DEVICE):MEASCNT9.FLNK","$(DEVICE):DONE9")
#! Field("$(DEVICE):MEASCNT9.VAL",16777215,0,"$(DEVICE):MEASCNT9.VAL")
#! Field("$(DEVICE):MEASCNT9.INPA",16777215,0,"$(DEVICE):MEASCNT9.INPA")
#! Link("$(DEVICE):MEASCNT9.INPA","$(DEVICE):MODMATCH9.VAL")
#! Field("$(DEVICE):MEASCNT9.INPB",16777215,0,"$(DEVICE):MEASCNT9.INPB")
#! Link("$(DEVICE):MEASCNT9.INPB","$(DEVICE):MEASCNT9.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK10") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):10:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH10")
  field(INPA, "EDEF:$(LOC):10:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT10")
  field(INPD, "$(DEVICE):DONE10")
  field(INPU, "EDEF:$(LOC):10:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):10:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE10")
  field(INPI, "EDEF:$(LOC):10:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):10:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE10") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):10:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE10")
}

record(seq, "$(DEVICE):RESETSEQ10") {
  field(DESC, "EDEF 10 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT10 PP")
  field(LNK2, "$(DEVICE):CHECK10")
  field(LNK3, "$(DEVICE):CHECK10.Y")
  field(LNK4, "$(DEVICE):CHECK10.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT10")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE10")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT10 PP")
}

record(bo, "$(DEVICE):INIT10") {
  field(DOL, "$(DEVICE):CHECK10")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH10") {
  field(FLNK, "$(DEVICE):MEASCNT10")
  field(DOL, "$(DEVICE):CHECK10")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE10") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE10")
  field(INPC, "$(DEVICE):CHECK10.Q")
}

record(calcout, "$(DEVICE):MEASCNT10") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE10")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH10")
  field(INPB, "$(DEVICE):MEASCNT10")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK10",1538,2184,0,0,"$(DEVICE):CHECK10")
#! Field("$(DEVICE):CHECK10.FLNK",16777215,1,"$(DEVICE):CHECK10.FLNK")
#! Link("$(DEVICE):CHECK10.FLNK","$(DEVICE):MODMATCH10")
#! Field("$(DEVICE):CHECK10.INPF",16777215,1,"$(DEVICE):CHECK10.INPF")
#! Field("$(DEVICE):CHECK10.INPP",16777215,1,"$(DEVICE):CHECK10.INPP")
#! Field("$(DEVICE):CHECK10.INPW",16777215,1,"$(DEVICE):CHECK10.INPW")
#! Field("$(DEVICE):CHECK10.Y",16777215,0,"$(DEVICE):CHECK10.Y")
#! Field("$(DEVICE):CHECK10.Z",16777215,0,"$(DEVICE):CHECK10.Z")
#! Field("$(DEVICE):CHECK10.VAL",16777215,1,"$(DEVICE):CHECK10.VAL")
#! Field("$(DEVICE):CHECK10.INPA",16777215,1,"$(DEVICE):CHECK10.INPA")
#! Field("$(DEVICE):CHECK10.INPB",16777215,1,"$(DEVICE):CHECK10.INPB")
#! Link("$(DEVICE):CHECK10.INPB","$(DEVICE):MEASCNT10.VAL")
#! Field("$(DEVICE):CHECK10.Q",16777215,1,"$(DEVICE):CHECK10.Q")
#! Field("$(DEVICE):CHECK10.INPD",16777215,1,"$(DEVICE):CHECK10.INPD")
#! Link("$(DEVICE):CHECK10.INPD","$(DEVICE):DONE10.VAL")
#! Field("$(DEVICE):CHECK10.INPU",16777215,1,"$(DEVICE):CHECK10.INPU")
#! Field("$(DEVICE):CHECK10.INPV",16777215,1,"$(DEVICE):CHECK10.INPV")
#! Field("$(DEVICE):CHECK10.SDIS",16777215,0,"$(DEVICE):CHECK10.SDIS")
#! Link("$(DEVICE):CHECK10.SDIS","$(DEVICE):STATE10.VAL")
#! Field("$(DEVICE):CHECK10.INPI",16777215,1,"$(DEVICE):CHECK10.INPI")
#! Field("$(DEVICE):CHECK10.INPJ",16777215,1,"$(DEVICE):CHECK10.INPJ")
#! Record("$(DEVICE):STATE10",1154,2201,0,1,"$(DEVICE):STATE10")
#! Field("$(DEVICE):STATE10.INPA",16777215,1,"$(DEVICE):STATE10.INPA")
#! Field("$(DEVICE):STATE10.INPB",16777215,1,"$(DEVICE):STATE10.INPB")
#! Link("$(DEVICE):STATE10.INPB","$(DEVICE):DONE10.VAL")
#! Field("$(DEVICE):STATE10.VAL",16777215,1,"$(DEVICE):STATE10.VAL")
#! Record("$(DEVICE):RESETSEQ10",1144,2895,0,0,"$(DEVICE):RESETSEQ10")
#! Field("$(DEVICE):RESETSEQ10.LNK1",16777215,1,"$(DEVICE):RESETSEQ10.LNK1")
#! Link("$(DEVICE):RESETSEQ10.LNK1","$(DEVICE):INIT10.VAL")
#! Field("$(DEVICE):RESETSEQ10.LNK2",16777215,1,"$(DEVICE):RESETSEQ10.LNK2")
#! Link("$(DEVICE):RESETSEQ10.LNK2","$(DEVICE):CHECK10.VAL")
#! Field("$(DEVICE):RESETSEQ10.LNK3",16777215,1,"$(DEVICE):RESETSEQ10.LNK3")
#! Link("$(DEVICE):RESETSEQ10.LNK3","$(DEVICE):CHECK10.Y")
#! Field("$(DEVICE):RESETSEQ10.LNK4",16777215,1,"$(DEVICE):RESETSEQ10.LNK4")
#! Link("$(DEVICE):RESETSEQ10.LNK4","$(DEVICE):CHECK10.Z")
#! Field("$(DEVICE):RESETSEQ10.LNK5",16777215,1,"$(DEVICE):RESETSEQ10.LNK5")
#! Link("$(DEVICE):RESETSEQ10.LNK5","$(DEVICE):MEASCNT10.VAL")
#! Field("$(DEVICE):RESETSEQ10.LNK6",16777215,1,"$(DEVICE):RESETSEQ10.LNK6")
#! Link("$(DEVICE):RESETSEQ10.LNK6","$(DEVICE):DONE10.VAL")
#! Field("$(DEVICE):RESETSEQ10.LNK8",16777215,1,"$(DEVICE):RESETSEQ10.LNK8")
#! Link("$(DEVICE):RESETSEQ10.LNK8","$(DEVICE):INIT10.VAL")
#! Record("$(DEVICE):INIT10",2010,2954,0,1,"$(DEVICE):INIT10")
#! Field("$(DEVICE):INIT10.VAL",16777215,0,"$(DEVICE):INIT10.VAL")
#! Field("$(DEVICE):INIT10.DOL",16777215,0,"$(DEVICE):INIT10.DOL")
#! Link("$(DEVICE):INIT10.DOL","$(DEVICE):CHECK10.VAL")
#! Record("$(DEVICE):MODMATCH10",1938,2448,0,0,"$(DEVICE):MODMATCH10")
#! Field("$(DEVICE):MODMATCH10.DOL",16777215,0,"$(DEVICE):MODMATCH10.DOL")
#! Link("$(DEVICE):MODMATCH10.DOL","$(DEVICE):CHECK10.VAL")
#! Field("$(DEVICE):MODMATCH10.FLNK",16777215,1,"$(DEVICE):MODMATCH10.FLNK")
#! Link("$(DEVICE):MODMATCH10.FLNK","$(DEVICE):MEASCNT10")
#! Field("$(DEVICE):MODMATCH10.VAL",16777215,1,"$(DEVICE):MODMATCH10.VAL")
#! Record("$(DEVICE):DONE10",2530,2306,0,0,"$(DEVICE):DONE10")
#! Field("$(DEVICE):DONE10.FLNK",16777215,0,"$(DEVICE):DONE10.FLNK")
#! Link("$(DEVICE):DONE10.FLNK","$(DEVICE):STATE10")
#! Field("$(DEVICE):DONE10.INPC",16777215,0,"$(DEVICE):DONE10.INPC")
#! Link("$(DEVICE):DONE10.INPC","$(DEVICE):CHECK10.Q")
#! Field("$(DEVICE):DONE10.VAL",16777215,0,"$(DEVICE):DONE10.VAL")
#! Record("$(DEVICE):MEASCNT10",2266,2526,0,0,"$(DEVICE):MEASCNT10")
#! Field("$(DEVICE):MEASCNT10.FLNK",16777215,1,"$(DEVICE):MEASCNT10.FLNK")
#! Link("$(DEVICE):MEASCNT10.FLNK","$(DEVICE):DONE10")
#! Field("$(DEVICE):MEASCNT10.VAL",16777215,0,"$(DEVICE):MEASCNT10.VAL")
#! Field("$(DEVICE):MEASCNT10.INPA",16777215,0,"$(DEVICE):MEASCNT10.INPA")
#! Link("$(DEVICE):MEASCNT10.INPA","$(DEVICE):MODMATCH10.VAL")
#! Field("$(DEVICE):MEASCNT10.INPB",16777215,0,"$(DEVICE):MEASCNT10.INPB")
#! Link("$(DEVICE):MEASCNT10.INPB","$(DEVICE):MEASCNT10.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK11") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):11:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH11")
  field(INPA, "EDEF:$(LOC):11:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT11")
  field(INPD, "$(DEVICE):DONE11")
  field(INPU, "EDEF:$(LOC):11:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):11:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE11")
  field(INPI, "EDEF:$(LOC):11:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):11:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE11") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):11:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE11")
}

record(seq, "$(DEVICE):RESETSEQ11") {
  field(DESC, "EDEF 11 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT11 PP")
  field(LNK2, "$(DEVICE):CHECK11")
  field(LNK3, "$(DEVICE):CHECK11.Y")
  field(LNK4, "$(DEVICE):CHECK11.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT11")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE11")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT11 PP")
}

record(bo, "$(DEVICE):INIT11") {
  field(DOL, "$(DEVICE):CHECK11")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH11") {
  field(FLNK, "$(DEVICE):MEASCNT11")
  field(DOL, "$(DEVICE):CHECK11")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE11") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE11")
  field(INPC, "$(DEVICE):CHECK11.Q")
}

record(calcout, "$(DEVICE):MEASCNT11") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE11")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH11")
  field(INPB, "$(DEVICE):MEASCNT11")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK11",1538,2184,0,0,"$(DEVICE):CHECK11")
#! Field("$(DEVICE):CHECK11.FLNK",16777215,1,"$(DEVICE):CHECK11.FLNK")
#! Link("$(DEVICE):CHECK11.FLNK","$(DEVICE):MODMATCH11")
#! Field("$(DEVICE):CHECK11.INPF",16777215,1,"$(DEVICE):CHECK11.INPF")
#! Field("$(DEVICE):CHECK11.INPP",16777215,1,"$(DEVICE):CHECK11.INPP")
#! Field("$(DEVICE):CHECK11.INPW",16777215,1,"$(DEVICE):CHECK11.INPW")
#! Field("$(DEVICE):CHECK11.Y",16777215,0,"$(DEVICE):CHECK11.Y")
#! Field("$(DEVICE):CHECK11.Z",16777215,0,"$(DEVICE):CHECK11.Z")
#! Field("$(DEVICE):CHECK11.VAL",16777215,1,"$(DEVICE):CHECK11.VAL")
#! Field("$(DEVICE):CHECK11.INPA",16777215,1,"$(DEVICE):CHECK11.INPA")
#! Field("$(DEVICE):CHECK11.INPB",16777215,1,"$(DEVICE):CHECK11.INPB")
#! Link("$(DEVICE):CHECK11.INPB","$(DEVICE):MEASCNT11.VAL")
#! Field("$(DEVICE):CHECK11.Q",16777215,1,"$(DEVICE):CHECK11.Q")
#! Field("$(DEVICE):CHECK11.INPD",16777215,1,"$(DEVICE):CHECK11.INPD")
#! Link("$(DEVICE):CHECK11.INPD","$(DEVICE):DONE11.VAL")
#! Field("$(DEVICE):CHECK11.INPU",16777215,1,"$(DEVICE):CHECK11.INPU")
#! Field("$(DEVICE):CHECK11.INPV",16777215,1,"$(DEVICE):CHECK11.INPV")
#! Field("$(DEVICE):CHECK11.SDIS",16777215,0,"$(DEVICE):CHECK11.SDIS")
#! Link("$(DEVICE):CHECK11.SDIS","$(DEVICE):STATE11.VAL")
#! Field("$(DEVICE):CHECK11.INPI",16777215,1,"$(DEVICE):CHECK11.INPI")
#! Field("$(DEVICE):CHECK11.INPJ",16777215,1,"$(DEVICE):CHECK11.INPJ")
#! Record("$(DEVICE):STATE11",1154,2201,0,1,"$(DEVICE):STATE11")
#! Field("$(DEVICE):STATE11.INPA",16777215,1,"$(DEVICE):STATE11.INPA")
#! Field("$(DEVICE):STATE11.INPB",16777215,1,"$(DEVICE):STATE11.INPB")
#! Link("$(DEVICE):STATE11.INPB","$(DEVICE):DONE11.VAL")
#! Field("$(DEVICE):STATE11.VAL",16777215,1,"$(DEVICE):STATE11.VAL")
#! Record("$(DEVICE):RESETSEQ11",1144,2895,0,0,"$(DEVICE):RESETSEQ11")
#! Field("$(DEVICE):RESETSEQ11.LNK1",16777215,1,"$(DEVICE):RESETSEQ11.LNK1")
#! Link("$(DEVICE):RESETSEQ11.LNK1","$(DEVICE):INIT11.VAL")
#! Field("$(DEVICE):RESETSEQ11.LNK2",16777215,1,"$(DEVICE):RESETSEQ11.LNK2")
#! Link("$(DEVICE):RESETSEQ11.LNK2","$(DEVICE):CHECK11.VAL")
#! Field("$(DEVICE):RESETSEQ11.LNK3",16777215,1,"$(DEVICE):RESETSEQ11.LNK3")
#! Link("$(DEVICE):RESETSEQ11.LNK3","$(DEVICE):CHECK11.Y")
#! Field("$(DEVICE):RESETSEQ11.LNK4",16777215,1,"$(DEVICE):RESETSEQ11.LNK4")
#! Link("$(DEVICE):RESETSEQ11.LNK4","$(DEVICE):CHECK11.Z")
#! Field("$(DEVICE):RESETSEQ11.LNK5",16777215,1,"$(DEVICE):RESETSEQ11.LNK5")
#! Link("$(DEVICE):RESETSEQ11.LNK5","$(DEVICE):MEASCNT11.VAL")
#! Field("$(DEVICE):RESETSEQ11.LNK6",16777215,1,"$(DEVICE):RESETSEQ11.LNK6")
#! Link("$(DEVICE):RESETSEQ11.LNK6","$(DEVICE):DONE11.VAL")
#! Field("$(DEVICE):RESETSEQ11.LNK8",16777215,1,"$(DEVICE):RESETSEQ11.LNK8")
#! Link("$(DEVICE):RESETSEQ11.LNK8","$(DEVICE):INIT11.VAL")
#! Record("$(DEVICE):INIT11",2010,2954,0,1,"$(DEVICE):INIT11")
#! Field("$(DEVICE):INIT11.VAL",16777215,0,"$(DEVICE):INIT11.VAL")
#! Field("$(DEVICE):INIT11.DOL",16777215,0,"$(DEVICE):INIT11.DOL")
#! Link("$(DEVICE):INIT11.DOL","$(DEVICE):CHECK11.VAL")
#! Record("$(DEVICE):MODMATCH11",1938,2448,0,0,"$(DEVICE):MODMATCH11")
#! Field("$(DEVICE):MODMATCH11.DOL",16777215,0,"$(DEVICE):MODMATCH11.DOL")
#! Link("$(DEVICE):MODMATCH11.DOL","$(DEVICE):CHECK11.VAL")
#! Field("$(DEVICE):MODMATCH11.FLNK",16777215,1,"$(DEVICE):MODMATCH11.FLNK")
#! Link("$(DEVICE):MODMATCH11.FLNK","$(DEVICE):MEASCNT11")
#! Field("$(DEVICE):MODMATCH11.VAL",16777215,1,"$(DEVICE):MODMATCH11.VAL")
#! Record("$(DEVICE):DONE11",2530,2306,0,0,"$(DEVICE):DONE11")
#! Field("$(DEVICE):DONE11.FLNK",16777215,0,"$(DEVICE):DONE11.FLNK")
#! Link("$(DEVICE):DONE11.FLNK","$(DEVICE):STATE11")
#! Field("$(DEVICE):DONE11.INPC",16777215,0,"$(DEVICE):DONE11.INPC")
#! Link("$(DEVICE):DONE11.INPC","$(DEVICE):CHECK11.Q")
#! Field("$(DEVICE):DONE11.VAL",16777215,0,"$(DEVICE):DONE11.VAL")
#! Record("$(DEVICE):MEASCNT11",2266,2526,0,0,"$(DEVICE):MEASCNT11")
#! Field("$(DEVICE):MEASCNT11.FLNK",16777215,1,"$(DEVICE):MEASCNT11.FLNK")
#! Link("$(DEVICE):MEASCNT11.FLNK","$(DEVICE):DONE11")
#! Field("$(DEVICE):MEASCNT11.VAL",16777215,0,"$(DEVICE):MEASCNT11.VAL")
#! Field("$(DEVICE):MEASCNT11.INPA",16777215,0,"$(DEVICE):MEASCNT11.INPA")
#! Link("$(DEVICE):MEASCNT11.INPA","$(DEVICE):MODMATCH11.VAL")
#! Field("$(DEVICE):MEASCNT11.INPB",16777215,0,"$(DEVICE):MEASCNT11.INPB")
#! Link("$(DEVICE):MEASCNT11.INPB","$(DEVICE):MEASCNT11.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK12") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):12:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH12")
  field(INPA, "EDEF:$(LOC):12:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT12")
  field(INPD, "$(DEVICE):DONE12")
  field(INPU, "EDEF:$(LOC):12:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):12:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE12")
  field(INPI, "EDEF:$(LOC):12:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):12:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE12") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):12:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE12")
}

record(seq, "$(DEVICE):RESETSEQ12") {
  field(DESC, "EDEF 12 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT12 PP")
  field(LNK2, "$(DEVICE):CHECK12")
  field(LNK3, "$(DEVICE):CHECK12.Y")
  field(LNK4, "$(DEVICE):CHECK12.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT12")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE12")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT12 PP")
}

record(bo, "$(DEVICE):INIT12") {
  field(DOL, "$(DEVICE):CHECK12")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH12") {
  field(FLNK, "$(DEVICE):MEASCNT12")
  field(DOL, "$(DEVICE):CHECK12")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE12") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE12")
  field(INPC, "$(DEVICE):CHECK12.Q")
}

record(calcout, "$(DEVICE):MEASCNT12") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE12")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH12")
  field(INPB, "$(DEVICE):MEASCNT12")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK12",1538,2184,0,0,"$(DEVICE):CHECK12")
#! Field("$(DEVICE):CHECK12.FLNK",16777215,1,"$(DEVICE):CHECK12.FLNK")
#! Link("$(DEVICE):CHECK12.FLNK","$(DEVICE):MODMATCH12")
#! Field("$(DEVICE):CHECK12.INPF",16777215,1,"$(DEVICE):CHECK12.INPF")
#! Field("$(DEVICE):CHECK12.INPP",16777215,1,"$(DEVICE):CHECK12.INPP")
#! Field("$(DEVICE):CHECK12.INPW",16777215,1,"$(DEVICE):CHECK12.INPW")
#! Field("$(DEVICE):CHECK12.Y",16777215,0,"$(DEVICE):CHECK12.Y")
#! Field("$(DEVICE):CHECK12.Z",16777215,0,"$(DEVICE):CHECK12.Z")
#! Field("$(DEVICE):CHECK12.VAL",16777215,1,"$(DEVICE):CHECK12.VAL")
#! Field("$(DEVICE):CHECK12.INPA",16777215,1,"$(DEVICE):CHECK12.INPA")
#! Field("$(DEVICE):CHECK12.INPB",16777215,1,"$(DEVICE):CHECK12.INPB")
#! Link("$(DEVICE):CHECK12.INPB","$(DEVICE):MEASCNT12.VAL")
#! Field("$(DEVICE):CHECK12.Q",16777215,1,"$(DEVICE):CHECK12.Q")
#! Field("$(DEVICE):CHECK12.INPD",16777215,1,"$(DEVICE):CHECK12.INPD")
#! Link("$(DEVICE):CHECK12.INPD","$(DEVICE):DONE12.VAL")
#! Field("$(DEVICE):CHECK12.INPU",16777215,1,"$(DEVICE):CHECK12.INPU")
#! Field("$(DEVICE):CHECK12.INPV",16777215,1,"$(DEVICE):CHECK12.INPV")
#! Field("$(DEVICE):CHECK12.SDIS",16777215,0,"$(DEVICE):CHECK12.SDIS")
#! Link("$(DEVICE):CHECK12.SDIS","$(DEVICE):STATE12.VAL")
#! Field("$(DEVICE):CHECK12.INPI",16777215,1,"$(DEVICE):CHECK12.INPI")
#! Field("$(DEVICE):CHECK12.INPJ",16777215,1,"$(DEVICE):CHECK12.INPJ")
#! Record("$(DEVICE):STATE12",1154,2201,0,1,"$(DEVICE):STATE12")
#! Field("$(DEVICE):STATE12.INPA",16777215,1,"$(DEVICE):STATE12.INPA")
#! Field("$(DEVICE):STATE12.INPB",16777215,1,"$(DEVICE):STATE12.INPB")
#! Link("$(DEVICE):STATE12.INPB","$(DEVICE):DONE12.VAL")
#! Field("$(DEVICE):STATE12.VAL",16777215,1,"$(DEVICE):STATE12.VAL")
#! Record("$(DEVICE):RESETSEQ12",1144,2895,0,0,"$(DEVICE):RESETSEQ12")
#! Field("$(DEVICE):RESETSEQ12.LNK1",16777215,1,"$(DEVICE):RESETSEQ12.LNK1")
#! Link("$(DEVICE):RESETSEQ12.LNK1","$(DEVICE):INIT12.VAL")
#! Field("$(DEVICE):RESETSEQ12.LNK2",16777215,1,"$(DEVICE):RESETSEQ12.LNK2")
#! Link("$(DEVICE):RESETSEQ12.LNK2","$(DEVICE):CHECK12.VAL")
#! Field("$(DEVICE):RESETSEQ12.LNK3",16777215,1,"$(DEVICE):RESETSEQ12.LNK3")
#! Link("$(DEVICE):RESETSEQ12.LNK3","$(DEVICE):CHECK12.Y")
#! Field("$(DEVICE):RESETSEQ12.LNK4",16777215,1,"$(DEVICE):RESETSEQ12.LNK4")
#! Link("$(DEVICE):RESETSEQ12.LNK4","$(DEVICE):CHECK12.Z")
#! Field("$(DEVICE):RESETSEQ12.LNK5",16777215,1,"$(DEVICE):RESETSEQ12.LNK5")
#! Link("$(DEVICE):RESETSEQ12.LNK5","$(DEVICE):MEASCNT12.VAL")
#! Field("$(DEVICE):RESETSEQ12.LNK6",16777215,1,"$(DEVICE):RESETSEQ12.LNK6")
#! Link("$(DEVICE):RESETSEQ12.LNK6","$(DEVICE):DONE12.VAL")
#! Field("$(DEVICE):RESETSEQ12.LNK8",16777215,1,"$(DEVICE):RESETSEQ12.LNK8")
#! Link("$(DEVICE):RESETSEQ12.LNK8","$(DEVICE):INIT12.VAL")
#! Record("$(DEVICE):INIT12",2010,2954,0,1,"$(DEVICE):INIT12")
#! Field("$(DEVICE):INIT12.VAL",16777215,0,"$(DEVICE):INIT12.VAL")
#! Field("$(DEVICE):INIT12.DOL",16777215,0,"$(DEVICE):INIT12.DOL")
#! Link("$(DEVICE):INIT12.DOL","$(DEVICE):CHECK12.VAL")
#! Record("$(DEVICE):MODMATCH12",1938,2448,0,0,"$(DEVICE):MODMATCH12")
#! Field("$(DEVICE):MODMATCH12.DOL",16777215,0,"$(DEVICE):MODMATCH12.DOL")
#! Link("$(DEVICE):MODMATCH12.DOL","$(DEVICE):CHECK12.VAL")
#! Field("$(DEVICE):MODMATCH12.FLNK",16777215,1,"$(DEVICE):MODMATCH12.FLNK")
#! Link("$(DEVICE):MODMATCH12.FLNK","$(DEVICE):MEASCNT12")
#! Field("$(DEVICE):MODMATCH12.VAL",16777215,1,"$(DEVICE):MODMATCH12.VAL")
#! Record("$(DEVICE):DONE12",2530,2306,0,0,"$(DEVICE):DONE12")
#! Field("$(DEVICE):DONE12.FLNK",16777215,0,"$(DEVICE):DONE12.FLNK")
#! Link("$(DEVICE):DONE12.FLNK","$(DEVICE):STATE12")
#! Field("$(DEVICE):DONE12.INPC",16777215,0,"$(DEVICE):DONE12.INPC")
#! Link("$(DEVICE):DONE12.INPC","$(DEVICE):CHECK12.Q")
#! Field("$(DEVICE):DONE12.VAL",16777215,0,"$(DEVICE):DONE12.VAL")
#! Record("$(DEVICE):MEASCNT12",2266,2526,0,0,"$(DEVICE):MEASCNT12")
#! Field("$(DEVICE):MEASCNT12.FLNK",16777215,1,"$(DEVICE):MEASCNT12.FLNK")
#! Link("$(DEVICE):MEASCNT12.FLNK","$(DEVICE):DONE12")
#! Field("$(DEVICE):MEASCNT12.VAL",16777215,0,"$(DEVICE):MEASCNT12.VAL")
#! Field("$(DEVICE):MEASCNT12.INPA",16777215,0,"$(DEVICE):MEASCNT12.INPA")
#! Link("$(DEVICE):MEASCNT12.INPA","$(DEVICE):MODMATCH12.VAL")
#! Field("$(DEVICE):MEASCNT12.INPB",16777215,0,"$(DEVICE):MEASCNT12.INPB")
#! Link("$(DEVICE):MEASCNT12.INPB","$(DEVICE):MEASCNT12.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK13") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):13:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH13")
  field(INPA, "EDEF:$(LOC):13:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT13")
  field(INPD, "$(DEVICE):DONE13")
  field(INPU, "EDEF:$(LOC):13:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):13:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE13")
  field(INPI, "EDEF:$(LOC):13:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):13:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE13") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):13:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE13")
}

record(seq, "$(DEVICE):RESETSEQ13") {
  field(DESC, "EDEF 13 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT13 PP")
  field(LNK2, "$(DEVICE):CHECK13")
  field(LNK3, "$(DEVICE):CHECK13.Y")
  field(LNK4, "$(DEVICE):CHECK13.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT13")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE13")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT13 PP")
}

record(bo, "$(DEVICE):INIT13") {
  field(DOL, "$(DEVICE):CHECK13")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH13") {
  field(FLNK, "$(DEVICE):MEASCNT13")
  field(DOL, "$(DEVICE):CHECK13")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE13") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE13")
  field(INPC, "$(DEVICE):CHECK13.Q")
}

record(calcout, "$(DEVICE):MEASCNT13") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE13")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH13")
  field(INPB, "$(DEVICE):MEASCNT13")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK13",1538,2184,0,0,"$(DEVICE):CHECK13")
#! Field("$(DEVICE):CHECK13.FLNK",16777215,1,"$(DEVICE):CHECK13.FLNK")
#! Link("$(DEVICE):CHECK13.FLNK","$(DEVICE):MODMATCH13")
#! Field("$(DEVICE):CHECK13.INPF",16777215,1,"$(DEVICE):CHECK13.INPF")
#! Field("$(DEVICE):CHECK13.INPP",16777215,1,"$(DEVICE):CHECK13.INPP")
#! Field("$(DEVICE):CHECK13.INPW",16777215,1,"$(DEVICE):CHECK13.INPW")
#! Field("$(DEVICE):CHECK13.Y",16777215,0,"$(DEVICE):CHECK13.Y")
#! Field("$(DEVICE):CHECK13.Z",16777215,0,"$(DEVICE):CHECK13.Z")
#! Field("$(DEVICE):CHECK13.VAL",16777215,1,"$(DEVICE):CHECK13.VAL")
#! Field("$(DEVICE):CHECK13.INPA",16777215,1,"$(DEVICE):CHECK13.INPA")
#! Field("$(DEVICE):CHECK13.INPB",16777215,1,"$(DEVICE):CHECK13.INPB")
#! Link("$(DEVICE):CHECK13.INPB","$(DEVICE):MEASCNT13.VAL")
#! Field("$(DEVICE):CHECK13.Q",16777215,1,"$(DEVICE):CHECK13.Q")
#! Field("$(DEVICE):CHECK13.INPD",16777215,1,"$(DEVICE):CHECK13.INPD")
#! Link("$(DEVICE):CHECK13.INPD","$(DEVICE):DONE13.VAL")
#! Field("$(DEVICE):CHECK13.INPU",16777215,1,"$(DEVICE):CHECK13.INPU")
#! Field("$(DEVICE):CHECK13.INPV",16777215,1,"$(DEVICE):CHECK13.INPV")
#! Field("$(DEVICE):CHECK13.SDIS",16777215,0,"$(DEVICE):CHECK13.SDIS")
#! Link("$(DEVICE):CHECK13.SDIS","$(DEVICE):STATE13.VAL")
#! Field("$(DEVICE):CHECK13.INPI",16777215,1,"$(DEVICE):CHECK13.INPI")
#! Field("$(DEVICE):CHECK13.INPJ",16777215,1,"$(DEVICE):CHECK13.INPJ")
#! Record("$(DEVICE):STATE13",1154,2201,0,1,"$(DEVICE):STATE13")
#! Field("$(DEVICE):STATE13.INPA",16777215,1,"$(DEVICE):STATE13.INPA")
#! Field("$(DEVICE):STATE13.INPB",16777215,1,"$(DEVICE):STATE13.INPB")
#! Link("$(DEVICE):STATE13.INPB","$(DEVICE):DONE13.VAL")
#! Field("$(DEVICE):STATE13.VAL",16777215,1,"$(DEVICE):STATE13.VAL")
#! Record("$(DEVICE):RESETSEQ13",1144,2895,0,0,"$(DEVICE):RESETSEQ13")
#! Field("$(DEVICE):RESETSEQ13.LNK1",16777215,1,"$(DEVICE):RESETSEQ13.LNK1")
#! Link("$(DEVICE):RESETSEQ13.LNK1","$(DEVICE):INIT13.VAL")
#! Field("$(DEVICE):RESETSEQ13.LNK2",16777215,1,"$(DEVICE):RESETSEQ13.LNK2")
#! Link("$(DEVICE):RESETSEQ13.LNK2","$(DEVICE):CHECK13.VAL")
#! Field("$(DEVICE):RESETSEQ13.LNK3",16777215,1,"$(DEVICE):RESETSEQ13.LNK3")
#! Link("$(DEVICE):RESETSEQ13.LNK3","$(DEVICE):CHECK13.Y")
#! Field("$(DEVICE):RESETSEQ13.LNK4",16777215,1,"$(DEVICE):RESETSEQ13.LNK4")
#! Link("$(DEVICE):RESETSEQ13.LNK4","$(DEVICE):CHECK13.Z")
#! Field("$(DEVICE):RESETSEQ13.LNK5",16777215,1,"$(DEVICE):RESETSEQ13.LNK5")
#! Link("$(DEVICE):RESETSEQ13.LNK5","$(DEVICE):MEASCNT13.VAL")
#! Field("$(DEVICE):RESETSEQ13.LNK6",16777215,1,"$(DEVICE):RESETSEQ13.LNK6")
#! Link("$(DEVICE):RESETSEQ13.LNK6","$(DEVICE):DONE13.VAL")
#! Field("$(DEVICE):RESETSEQ13.LNK8",16777215,1,"$(DEVICE):RESETSEQ13.LNK8")
#! Link("$(DEVICE):RESETSEQ13.LNK8","$(DEVICE):INIT13.VAL")
#! Record("$(DEVICE):INIT13",2010,2954,0,1,"$(DEVICE):INIT13")
#! Field("$(DEVICE):INIT13.VAL",16777215,0,"$(DEVICE):INIT13.VAL")
#! Field("$(DEVICE):INIT13.DOL",16777215,0,"$(DEVICE):INIT13.DOL")
#! Link("$(DEVICE):INIT13.DOL","$(DEVICE):CHECK13.VAL")
#! Record("$(DEVICE):MODMATCH13",1938,2448,0,0,"$(DEVICE):MODMATCH13")
#! Field("$(DEVICE):MODMATCH13.DOL",16777215,0,"$(DEVICE):MODMATCH13.DOL")
#! Link("$(DEVICE):MODMATCH13.DOL","$(DEVICE):CHECK13.VAL")
#! Field("$(DEVICE):MODMATCH13.FLNK",16777215,1,"$(DEVICE):MODMATCH13.FLNK")
#! Link("$(DEVICE):MODMATCH13.FLNK","$(DEVICE):MEASCNT13")
#! Field("$(DEVICE):MODMATCH13.VAL",16777215,1,"$(DEVICE):MODMATCH13.VAL")
#! Record("$(DEVICE):DONE13",2530,2306,0,0,"$(DEVICE):DONE13")
#! Field("$(DEVICE):DONE13.FLNK",16777215,0,"$(DEVICE):DONE13.FLNK")
#! Link("$(DEVICE):DONE13.FLNK","$(DEVICE):STATE13")
#! Field("$(DEVICE):DONE13.INPC",16777215,0,"$(DEVICE):DONE13.INPC")
#! Link("$(DEVICE):DONE13.INPC","$(DEVICE):CHECK13.Q")
#! Field("$(DEVICE):DONE13.VAL",16777215,0,"$(DEVICE):DONE13.VAL")
#! Record("$(DEVICE):MEASCNT13",2266,2526,0,0,"$(DEVICE):MEASCNT13")
#! Field("$(DEVICE):MEASCNT13.FLNK",16777215,1,"$(DEVICE):MEASCNT13.FLNK")
#! Link("$(DEVICE):MEASCNT13.FLNK","$(DEVICE):DONE13")
#! Field("$(DEVICE):MEASCNT13.VAL",16777215,0,"$(DEVICE):MEASCNT13.VAL")
#! Field("$(DEVICE):MEASCNT13.INPA",16777215,0,"$(DEVICE):MEASCNT13.INPA")
#! Link("$(DEVICE):MEASCNT13.INPA","$(DEVICE):MODMATCH13.VAL")
#! Field("$(DEVICE):MEASCNT13.INPB",16777215,0,"$(DEVICE):MEASCNT13.INPB")
#! Link("$(DEVICE):MEASCNT13.INPB","$(DEVICE):MEASCNT13.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK14") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):14:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH14")
  field(INPA, "EDEF:$(LOC):14:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT14")
  field(INPD, "$(DEVICE):DONE14")
  field(INPU, "EDEF:$(LOC):14:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):14:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE14")
  field(INPI, "EDEF:$(LOC):14:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):14:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE14") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):14:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE14")
}

record(seq, "$(DEVICE):RESETSEQ14") {
  field(DESC, "EDEF 14 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT14 PP")
  field(LNK2, "$(DEVICE):CHECK14")
  field(LNK3, "$(DEVICE):CHECK14.Y")
  field(LNK4, "$(DEVICE):CHECK14.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT14")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE14")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT14 PP")
}

record(bo, "$(DEVICE):INIT14") {
  field(DOL, "$(DEVICE):CHECK14")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH14") {
  field(FLNK, "$(DEVICE):MEASCNT14")
  field(DOL, "$(DEVICE):CHECK14")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE14") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE14")
  field(INPC, "$(DEVICE):CHECK14.Q")
}

record(calcout, "$(DEVICE):MEASCNT14") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE14")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH14")
  field(INPB, "$(DEVICE):MEASCNT14")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK14",1538,2184,0,0,"$(DEVICE):CHECK14")
#! Field("$(DEVICE):CHECK14.FLNK",16777215,1,"$(DEVICE):CHECK14.FLNK")
#! Link("$(DEVICE):CHECK14.FLNK","$(DEVICE):MODMATCH14")
#! Field("$(DEVICE):CHECK14.INPF",16777215,1,"$(DEVICE):CHECK14.INPF")
#! Field("$(DEVICE):CHECK14.INPP",16777215,1,"$(DEVICE):CHECK14.INPP")
#! Field("$(DEVICE):CHECK14.INPW",16777215,1,"$(DEVICE):CHECK14.INPW")
#! Field("$(DEVICE):CHECK14.Y",16777215,0,"$(DEVICE):CHECK14.Y")
#! Field("$(DEVICE):CHECK14.Z",16777215,0,"$(DEVICE):CHECK14.Z")
#! Field("$(DEVICE):CHECK14.VAL",16777215,1,"$(DEVICE):CHECK14.VAL")
#! Field("$(DEVICE):CHECK14.INPA",16777215,1,"$(DEVICE):CHECK14.INPA")
#! Field("$(DEVICE):CHECK14.INPB",16777215,1,"$(DEVICE):CHECK14.INPB")
#! Link("$(DEVICE):CHECK14.INPB","$(DEVICE):MEASCNT14.VAL")
#! Field("$(DEVICE):CHECK14.Q",16777215,1,"$(DEVICE):CHECK14.Q")
#! Field("$(DEVICE):CHECK14.INPD",16777215,1,"$(DEVICE):CHECK14.INPD")
#! Link("$(DEVICE):CHECK14.INPD","$(DEVICE):DONE14.VAL")
#! Field("$(DEVICE):CHECK14.INPU",16777215,1,"$(DEVICE):CHECK14.INPU")
#! Field("$(DEVICE):CHECK14.INPV",16777215,1,"$(DEVICE):CHECK14.INPV")
#! Field("$(DEVICE):CHECK14.SDIS",16777215,0,"$(DEVICE):CHECK14.SDIS")
#! Link("$(DEVICE):CHECK14.SDIS","$(DEVICE):STATE14.VAL")
#! Field("$(DEVICE):CHECK14.INPI",16777215,1,"$(DEVICE):CHECK14.INPI")
#! Field("$(DEVICE):CHECK14.INPJ",16777215,1,"$(DEVICE):CHECK14.INPJ")
#! Record("$(DEVICE):STATE14",1154,2201,0,1,"$(DEVICE):STATE14")
#! Field("$(DEVICE):STATE14.INPA",16777215,1,"$(DEVICE):STATE14.INPA")
#! Field("$(DEVICE):STATE14.INPB",16777215,1,"$(DEVICE):STATE14.INPB")
#! Link("$(DEVICE):STATE14.INPB","$(DEVICE):DONE14.VAL")
#! Field("$(DEVICE):STATE14.VAL",16777215,1,"$(DEVICE):STATE14.VAL")
#! Record("$(DEVICE):RESETSEQ14",1144,2895,0,0,"$(DEVICE):RESETSEQ14")
#! Field("$(DEVICE):RESETSEQ14.LNK1",16777215,1,"$(DEVICE):RESETSEQ14.LNK1")
#! Link("$(DEVICE):RESETSEQ14.LNK1","$(DEVICE):INIT14.VAL")
#! Field("$(DEVICE):RESETSEQ14.LNK2",16777215,1,"$(DEVICE):RESETSEQ14.LNK2")
#! Link("$(DEVICE):RESETSEQ14.LNK2","$(DEVICE):CHECK14.VAL")
#! Field("$(DEVICE):RESETSEQ14.LNK3",16777215,1,"$(DEVICE):RESETSEQ14.LNK3")
#! Link("$(DEVICE):RESETSEQ14.LNK3","$(DEVICE):CHECK14.Y")
#! Field("$(DEVICE):RESETSEQ14.LNK4",16777215,1,"$(DEVICE):RESETSEQ14.LNK4")
#! Link("$(DEVICE):RESETSEQ14.LNK4","$(DEVICE):CHECK14.Z")
#! Field("$(DEVICE):RESETSEQ14.LNK5",16777215,1,"$(DEVICE):RESETSEQ14.LNK5")
#! Link("$(DEVICE):RESETSEQ14.LNK5","$(DEVICE):MEASCNT14.VAL")
#! Field("$(DEVICE):RESETSEQ14.LNK6",16777215,1,"$(DEVICE):RESETSEQ14.LNK6")
#! Link("$(DEVICE):RESETSEQ14.LNK6","$(DEVICE):DONE14.VAL")
#! Field("$(DEVICE):RESETSEQ14.LNK8",16777215,1,"$(DEVICE):RESETSEQ14.LNK8")
#! Link("$(DEVICE):RESETSEQ14.LNK8","$(DEVICE):INIT14.VAL")
#! Record("$(DEVICE):INIT14",2010,2954,0,1,"$(DEVICE):INIT14")
#! Field("$(DEVICE):INIT14.VAL",16777215,0,"$(DEVICE):INIT14.VAL")
#! Field("$(DEVICE):INIT14.DOL",16777215,0,"$(DEVICE):INIT14.DOL")
#! Link("$(DEVICE):INIT14.DOL","$(DEVICE):CHECK14.VAL")
#! Record("$(DEVICE):MODMATCH14",1938,2448,0,0,"$(DEVICE):MODMATCH14")
#! Field("$(DEVICE):MODMATCH14.DOL",16777215,0,"$(DEVICE):MODMATCH14.DOL")
#! Link("$(DEVICE):MODMATCH14.DOL","$(DEVICE):CHECK14.VAL")
#! Field("$(DEVICE):MODMATCH14.FLNK",16777215,1,"$(DEVICE):MODMATCH14.FLNK")
#! Link("$(DEVICE):MODMATCH14.FLNK","$(DEVICE):MEASCNT14")
#! Field("$(DEVICE):MODMATCH14.VAL",16777215,1,"$(DEVICE):MODMATCH14.VAL")
#! Record("$(DEVICE):DONE14",2530,2306,0,0,"$(DEVICE):DONE14")
#! Field("$(DEVICE):DONE14.FLNK",16777215,0,"$(DEVICE):DONE14.FLNK")
#! Link("$(DEVICE):DONE14.FLNK","$(DEVICE):STATE14")
#! Field("$(DEVICE):DONE14.INPC",16777215,0,"$(DEVICE):DONE14.INPC")
#! Link("$(DEVICE):DONE14.INPC","$(DEVICE):CHECK14.Q")
#! Field("$(DEVICE):DONE14.VAL",16777215,0,"$(DEVICE):DONE14.VAL")
#! Record("$(DEVICE):MEASCNT14",2266,2526,0,0,"$(DEVICE):MEASCNT14")
#! Field("$(DEVICE):MEASCNT14.FLNK",16777215,1,"$(DEVICE):MEASCNT14.FLNK")
#! Link("$(DEVICE):MEASCNT14.FLNK","$(DEVICE):DONE14")
#! Field("$(DEVICE):MEASCNT14.VAL",16777215,0,"$(DEVICE):MEASCNT14.VAL")
#! Field("$(DEVICE):MEASCNT14.INPA",16777215,0,"$(DEVICE):MEASCNT14.INPA")
#! Link("$(DEVICE):MEASCNT14.INPA","$(DEVICE):MODMATCH14.VAL")
#! Field("$(DEVICE):MEASCNT14.INPB",16777215,0,"$(DEVICE):MEASCNT14.INPB")
#! Link("$(DEVICE):MEASCNT14.INPB","$(DEVICE):MEASCNT14.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK15") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):15:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH15")
  field(INPA, "EDEF:$(LOC):15:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT15")
  field(INPD, "$(DEVICE):DONE15")
  field(INPU, "EDEF:$(LOC):15:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):15:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE15")
  field(INPI, "EDEF:$(LOC):15:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):15:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE15") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):15:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE15")
}

record(seq, "$(DEVICE):RESETSEQ15") {
  field(DESC, "EDEF 15 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT15 PP")
  field(LNK2, "$(DEVICE):CHECK15")
  field(LNK3, "$(DEVICE):CHECK15.Y")
  field(LNK4, "$(DEVICE):CHECK15.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT15")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE15")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT15 PP")
}

record(bo, "$(DEVICE):INIT15") {
  field(DOL, "$(DEVICE):CHECK15")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH15") {
  field(FLNK, "$(DEVICE):MEASCNT15")
  field(DOL, "$(DEVICE):CHECK15")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE15") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE15")
  field(INPC, "$(DEVICE):CHECK15.Q")
}

record(calcout, "$(DEVICE):MEASCNT15") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE15")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH15")
  field(INPB, "$(DEVICE):MEASCNT15")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK15",1538,2184,0,0,"$(DEVICE):CHECK15")
#! Field("$(DEVICE):CHECK15.FLNK",16777215,1,"$(DEVICE):CHECK15.FLNK")
#! Link("$(DEVICE):CHECK15.FLNK","$(DEVICE):MODMATCH15")
#! Field("$(DEVICE):CHECK15.INPF",16777215,1,"$(DEVICE):CHECK15.INPF")
#! Field("$(DEVICE):CHECK15.INPP",16777215,1,"$(DEVICE):CHECK15.INPP")
#! Field("$(DEVICE):CHECK15.INPW",16777215,1,"$(DEVICE):CHECK15.INPW")
#! Field("$(DEVICE):CHECK15.Y",16777215,0,"$(DEVICE):CHECK15.Y")
#! Field("$(DEVICE):CHECK15.Z",16777215,0,"$(DEVICE):CHECK15.Z")
#! Field("$(DEVICE):CHECK15.VAL",16777215,1,"$(DEVICE):CHECK15.VAL")
#! Field("$(DEVICE):CHECK15.INPA",16777215,1,"$(DEVICE):CHECK15.INPA")
#! Field("$(DEVICE):CHECK15.INPB",16777215,1,"$(DEVICE):CHECK15.INPB")
#! Link("$(DEVICE):CHECK15.INPB","$(DEVICE):MEASCNT15.VAL")
#! Field("$(DEVICE):CHECK15.Q",16777215,1,"$(DEVICE):CHECK15.Q")
#! Field("$(DEVICE):CHECK15.INPD",16777215,1,"$(DEVICE):CHECK15.INPD")
#! Link("$(DEVICE):CHECK15.INPD","$(DEVICE):DONE15.VAL")
#! Field("$(DEVICE):CHECK15.INPU",16777215,1,"$(DEVICE):CHECK15.INPU")
#! Field("$(DEVICE):CHECK15.INPV",16777215,1,"$(DEVICE):CHECK15.INPV")
#! Field("$(DEVICE):CHECK15.SDIS",16777215,0,"$(DEVICE):CHECK15.SDIS")
#! Link("$(DEVICE):CHECK15.SDIS","$(DEVICE):STATE15.VAL")
#! Field("$(DEVICE):CHECK15.INPI",16777215,1,"$(DEVICE):CHECK15.INPI")
#! Field("$(DEVICE):CHECK15.INPJ",16777215,1,"$(DEVICE):CHECK15.INPJ")
#! Record("$(DEVICE):STATE15",1154,2201,0,1,"$(DEVICE):STATE15")
#! Field("$(DEVICE):STATE15.INPA",16777215,1,"$(DEVICE):STATE15.INPA")
#! Field("$(DEVICE):STATE15.INPB",16777215,1,"$(DEVICE):STATE15.INPB")
#! Link("$(DEVICE):STATE15.INPB","$(DEVICE):DONE15.VAL")
#! Field("$(DEVICE):STATE15.VAL",16777215,1,"$(DEVICE):STATE15.VAL")
#! Record("$(DEVICE):RESETSEQ15",1144,2895,0,0,"$(DEVICE):RESETSEQ15")
#! Field("$(DEVICE):RESETSEQ15.LNK1",16777215,1,"$(DEVICE):RESETSEQ15.LNK1")
#! Link("$(DEVICE):RESETSEQ15.LNK1","$(DEVICE):INIT15.VAL")
#! Field("$(DEVICE):RESETSEQ15.LNK2",16777215,1,"$(DEVICE):RESETSEQ15.LNK2")
#! Link("$(DEVICE):RESETSEQ15.LNK2","$(DEVICE):CHECK15.VAL")
#! Field("$(DEVICE):RESETSEQ15.LNK3",16777215,1,"$(DEVICE):RESETSEQ15.LNK3")
#! Link("$(DEVICE):RESETSEQ15.LNK3","$(DEVICE):CHECK15.Y")
#! Field("$(DEVICE):RESETSEQ15.LNK4",16777215,1,"$(DEVICE):RESETSEQ15.LNK4")
#! Link("$(DEVICE):RESETSEQ15.LNK4","$(DEVICE):CHECK15.Z")
#! Field("$(DEVICE):RESETSEQ15.LNK5",16777215,1,"$(DEVICE):RESETSEQ15.LNK5")
#! Link("$(DEVICE):RESETSEQ15.LNK5","$(DEVICE):MEASCNT15.VAL")
#! Field("$(DEVICE):RESETSEQ15.LNK6",16777215,1,"$(DEVICE):RESETSEQ15.LNK6")
#! Link("$(DEVICE):RESETSEQ15.LNK6","$(DEVICE):DONE15.VAL")
#! Field("$(DEVICE):RESETSEQ15.LNK8",16777215,1,"$(DEVICE):RESETSEQ15.LNK8")
#! Link("$(DEVICE):RESETSEQ15.LNK8","$(DEVICE):INIT15.VAL")
#! Record("$(DEVICE):INIT15",2010,2954,0,1,"$(DEVICE):INIT15")
#! Field("$(DEVICE):INIT15.VAL",16777215,0,"$(DEVICE):INIT15.VAL")
#! Field("$(DEVICE):INIT15.DOL",16777215,0,"$(DEVICE):INIT15.DOL")
#! Link("$(DEVICE):INIT15.DOL","$(DEVICE):CHECK15.VAL")
#! Record("$(DEVICE):MODMATCH15",1938,2448,0,0,"$(DEVICE):MODMATCH15")
#! Field("$(DEVICE):MODMATCH15.DOL",16777215,0,"$(DEVICE):MODMATCH15.DOL")
#! Link("$(DEVICE):MODMATCH15.DOL","$(DEVICE):CHECK15.VAL")
#! Field("$(DEVICE):MODMATCH15.FLNK",16777215,1,"$(DEVICE):MODMATCH15.FLNK")
#! Link("$(DEVICE):MODMATCH15.FLNK","$(DEVICE):MEASCNT15")
#! Field("$(DEVICE):MODMATCH15.VAL",16777215,1,"$(DEVICE):MODMATCH15.VAL")
#! Record("$(DEVICE):DONE15",2530,2306,0,0,"$(DEVICE):DONE15")
#! Field("$(DEVICE):DONE15.FLNK",16777215,0,"$(DEVICE):DONE15.FLNK")
#! Link("$(DEVICE):DONE15.FLNK","$(DEVICE):STATE15")
#! Field("$(DEVICE):DONE15.INPC",16777215,0,"$(DEVICE):DONE15.INPC")
#! Link("$(DEVICE):DONE15.INPC","$(DEVICE):CHECK15.Q")
#! Field("$(DEVICE):DONE15.VAL",16777215,0,"$(DEVICE):DONE15.VAL")
#! Record("$(DEVICE):MEASCNT15",2266,2526,0,0,"$(DEVICE):MEASCNT15")
#! Field("$(DEVICE):MEASCNT15.FLNK",16777215,1,"$(DEVICE):MEASCNT15.FLNK")
#! Link("$(DEVICE):MEASCNT15.FLNK","$(DEVICE):DONE15")
#! Field("$(DEVICE):MEASCNT15.VAL",16777215,0,"$(DEVICE):MEASCNT15.VAL")
#! Field("$(DEVICE):MEASCNT15.INPA",16777215,0,"$(DEVICE):MEASCNT15.INPA")
#! Link("$(DEVICE):MEASCNT15.INPA","$(DEVICE):MODMATCH15.VAL")
#! Field("$(DEVICE):MEASCNT15.INPB",16777215,0,"$(DEVICE):MEASCNT15.INPB")
#! Link("$(DEVICE):MEASCNT15.INPB","$(DEVICE):MEASCNT15.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECK1H") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):16:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCH1H")
  field(INPA, "EDEF:$(LOC):16:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNT1H")
  field(INPD, "$(DEVICE):DONE1H")
  field(INPU, "EDEF:$(LOC):16:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):16:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE16")
  field(INPI, "EDEF:$(LOC):16:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):16:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE16") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):16:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONE1H")
}

record(seq, "$(DEVICE):RESETSEQ16") {
  field(DESC, "EDEF 1H Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INIT1H PP")
  field(LNK2, "$(DEVICE):CHECK1H")
  field(LNK3, "$(DEVICE):CHECK1H.Y")
  field(LNK4, "$(DEVICE):CHECK1H.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNT1H")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONE1H")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INIT1H PP")
}

record(bo, "$(DEVICE):INIT1H") {
  field(DOL, "$(DEVICE):CHECK1H")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCH1H") {
  field(FLNK, "$(DEVICE):MEASCNT1H")
  field(DOL, "$(DEVICE):CHECK1H")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONE1H") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE16")
  field(INPC, "$(DEVICE):CHECK1H.Q")
}

record(calcout, "$(DEVICE):MEASCNT1H") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONE1H")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCH1H")
  field(INPB, "$(DEVICE):MEASCNT1H")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECK1H",1538,2184,0,0,"$(DEVICE):CHECK1H")
#! Field("$(DEVICE):CHECK1H.FLNK",16777215,1,"$(DEVICE):CHECK1H.FLNK")
#! Link("$(DEVICE):CHECK1H.FLNK","$(DEVICE):MODMATCH1H")
#! Field("$(DEVICE):CHECK1H.INPF",16777215,1,"$(DEVICE):CHECK1H.INPF")
#! Field("$(DEVICE):CHECK1H.INPP",16777215,1,"$(DEVICE):CHECK1H.INPP")
#! Field("$(DEVICE):CHECK1H.INPW",16777215,1,"$(DEVICE):CHECK1H.INPW")
#! Field("$(DEVICE):CHECK1H.Y",16777215,0,"$(DEVICE):CHECK1H.Y")
#! Field("$(DEVICE):CHECK1H.Z",16777215,0,"$(DEVICE):CHECK1H.Z")
#! Field("$(DEVICE):CHECK1H.VAL",16777215,1,"$(DEVICE):CHECK1H.VAL")
#! Field("$(DEVICE):CHECK1H.INPA",16777215,1,"$(DEVICE):CHECK1H.INPA")
#! Field("$(DEVICE):CHECK1H.INPB",16777215,1,"$(DEVICE):CHECK1H.INPB")
#! Link("$(DEVICE):CHECK1H.INPB","$(DEVICE):MEASCNT1H.VAL")
#! Field("$(DEVICE):CHECK1H.Q",16777215,1,"$(DEVICE):CHECK1H.Q")
#! Field("$(DEVICE):CHECK1H.INPD",16777215,1,"$(DEVICE):CHECK1H.INPD")
#! Link("$(DEVICE):CHECK1H.INPD","$(DEVICE):DONE1H.VAL")
#! Field("$(DEVICE):CHECK1H.INPU",16777215,1,"$(DEVICE):CHECK1H.INPU")
#! Field("$(DEVICE):CHECK1H.INPV",16777215,1,"$(DEVICE):CHECK1H.INPV")
#! Field("$(DEVICE):CHECK1H.SDIS",16777215,0,"$(DEVICE):CHECK1H.SDIS")
#! Link("$(DEVICE):CHECK1H.SDIS","$(DEVICE):STATE16.VAL")
#! Field("$(DEVICE):CHECK1H.INPI",16777215,1,"$(DEVICE):CHECK1H.INPI")
#! Field("$(DEVICE):CHECK1H.INPJ",16777215,1,"$(DEVICE):CHECK1H.INPJ")
#! Record("$(DEVICE):STATE16",1154,2201,0,1,"$(DEVICE):STATE16")
#! Field("$(DEVICE):STATE16.INPA",16777215,1,"$(DEVICE):STATE16.INPA")
#! Field("$(DEVICE):STATE16.INPB",16777215,1,"$(DEVICE):STATE16.INPB")
#! Link("$(DEVICE):STATE16.INPB","$(DEVICE):DONE1H.VAL")
#! Field("$(DEVICE):STATE16.VAL",16777215,1,"$(DEVICE):STATE16.VAL")
#! Record("$(DEVICE):RESETSEQ16",1144,2895,0,0,"$(DEVICE):RESETSEQ16")
#! Field("$(DEVICE):RESETSEQ16.LNK1",16777215,1,"$(DEVICE):RESETSEQ16.LNK1")
#! Link("$(DEVICE):RESETSEQ16.LNK1","$(DEVICE):INIT1H.VAL")
#! Field("$(DEVICE):RESETSEQ16.LNK2",16777215,1,"$(DEVICE):RESETSEQ16.LNK2")
#! Link("$(DEVICE):RESETSEQ16.LNK2","$(DEVICE):CHECK1H.VAL")
#! Field("$(DEVICE):RESETSEQ16.LNK3",16777215,1,"$(DEVICE):RESETSEQ16.LNK3")
#! Link("$(DEVICE):RESETSEQ16.LNK3","$(DEVICE):CHECK1H.Y")
#! Field("$(DEVICE):RESETSEQ16.LNK4",16777215,1,"$(DEVICE):RESETSEQ16.LNK4")
#! Link("$(DEVICE):RESETSEQ16.LNK4","$(DEVICE):CHECK1H.Z")
#! Field("$(DEVICE):RESETSEQ16.LNK5",16777215,1,"$(DEVICE):RESETSEQ16.LNK5")
#! Link("$(DEVICE):RESETSEQ16.LNK5","$(DEVICE):MEASCNT1H.VAL")
#! Field("$(DEVICE):RESETSEQ16.LNK6",16777215,1,"$(DEVICE):RESETSEQ16.LNK6")
#! Link("$(DEVICE):RESETSEQ16.LNK6","$(DEVICE):DONE1H.VAL")
#! Field("$(DEVICE):RESETSEQ16.LNK8",16777215,1,"$(DEVICE):RESETSEQ16.LNK8")
#! Link("$(DEVICE):RESETSEQ16.LNK8","$(DEVICE):INIT1H.VAL")
#! Record("$(DEVICE):INIT1H",2010,2954,0,1,"$(DEVICE):INIT1H")
#! Field("$(DEVICE):INIT1H.VAL",16777215,0,"$(DEVICE):INIT1H.VAL")
#! Field("$(DEVICE):INIT1H.DOL",16777215,0,"$(DEVICE):INIT1H.DOL")
#! Link("$(DEVICE):INIT1H.DOL","$(DEVICE):CHECK1H.VAL")
#! Record("$(DEVICE):MODMATCH1H",1938,2448,0,0,"$(DEVICE):MODMATCH1H")
#! Field("$(DEVICE):MODMATCH1H.DOL",16777215,0,"$(DEVICE):MODMATCH1H.DOL")
#! Link("$(DEVICE):MODMATCH1H.DOL","$(DEVICE):CHECK1H.VAL")
#! Field("$(DEVICE):MODMATCH1H.FLNK",16777215,1,"$(DEVICE):MODMATCH1H.FLNK")
#! Link("$(DEVICE):MODMATCH1H.FLNK","$(DEVICE):MEASCNT1H")
#! Field("$(DEVICE):MODMATCH1H.VAL",16777215,1,"$(DEVICE):MODMATCH1H.VAL")
#! Record("$(DEVICE):DONE1H",2530,2306,0,0,"$(DEVICE):DONE1H")
#! Field("$(DEVICE):DONE1H.FLNK",16777215,0,"$(DEVICE):DONE1H.FLNK")
#! Link("$(DEVICE):DONE1H.FLNK","$(DEVICE):STATE16")
#! Field("$(DEVICE):DONE1H.INPC",16777215,0,"$(DEVICE):DONE1H.INPC")
#! Link("$(DEVICE):DONE1H.INPC","$(DEVICE):CHECK1H.Q")
#! Field("$(DEVICE):DONE1H.VAL",16777215,0,"$(DEVICE):DONE1H.VAL")
#! Record("$(DEVICE):MEASCNT1H",2266,2526,0,0,"$(DEVICE):MEASCNT1H")
#! Field("$(DEVICE):MEASCNT1H.FLNK",16777215,1,"$(DEVICE):MEASCNT1H.FLNK")
#! Link("$(DEVICE):MEASCNT1H.FLNK","$(DEVICE):DONE1H")
#! Field("$(DEVICE):MEASCNT1H.VAL",16777215,0,"$(DEVICE):MEASCNT1H.VAL")
#! Field("$(DEVICE):MEASCNT1H.INPA",16777215,0,"$(DEVICE):MEASCNT1H.INPA")
#! Link("$(DEVICE):MEASCNT1H.INPA","$(DEVICE):MODMATCH1H.VAL")
#! Field("$(DEVICE):MEASCNT1H.INPB",16777215,0,"$(DEVICE):MEASCNT1H.INPB")
#! Link("$(DEVICE):MEASCNT1H.INPB","$(DEVICE):MEASCNT1H.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECKTH") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):17:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCHTH")
  field(INPA, "EDEF:$(LOC):17:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNTTH")
  field(INPD, "$(DEVICE):DONETH")
  field(INPU, "EDEF:$(LOC):17:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):17:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE17")
  field(INPI, "EDEF:$(LOC):17:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):17:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE17") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):17:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONETH")
}

record(seq, "$(DEVICE):RESETSEQ17") {
  field(DESC, "EDEF TH Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INITTH PP")
  field(LNK2, "$(DEVICE):CHECKTH")
  field(LNK3, "$(DEVICE):CHECKTH.Y")
  field(LNK4, "$(DEVICE):CHECKTH.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNTTH")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONETH")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INITTH PP")
}

record(bo, "$(DEVICE):INITTH") {
  field(DOL, "$(DEVICE):CHECKTH")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCHTH") {
  field(FLNK, "$(DEVICE):MEASCNTTH")
  field(DOL, "$(DEVICE):CHECKTH")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONETH") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE17")
  field(INPC, "$(DEVICE):CHECKTH.Q")
}

record(calcout, "$(DEVICE):MEASCNTTH") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONETH")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCHTH")
  field(INPB, "$(DEVICE):MEASCNTTH")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECKTH",1538,2184,0,0,"$(DEVICE):CHECKTH")
#! Field("$(DEVICE):CHECKTH.FLNK",16777215,1,"$(DEVICE):CHECKTH.FLNK")
#! Link("$(DEVICE):CHECKTH.FLNK","$(DEVICE):MODMATCHTH")
#! Field("$(DEVICE):CHECKTH.INPF",16777215,1,"$(DEVICE):CHECKTH.INPF")
#! Field("$(DEVICE):CHECKTH.INPP",16777215,1,"$(DEVICE):CHECKTH.INPP")
#! Field("$(DEVICE):CHECKTH.INPW",16777215,1,"$(DEVICE):CHECKTH.INPW")
#! Field("$(DEVICE):CHECKTH.Y",16777215,0,"$(DEVICE):CHECKTH.Y")
#! Field("$(DEVICE):CHECKTH.Z",16777215,0,"$(DEVICE):CHECKTH.Z")
#! Field("$(DEVICE):CHECKTH.VAL",16777215,1,"$(DEVICE):CHECKTH.VAL")
#! Field("$(DEVICE):CHECKTH.INPA",16777215,1,"$(DEVICE):CHECKTH.INPA")
#! Field("$(DEVICE):CHECKTH.INPB",16777215,1,"$(DEVICE):CHECKTH.INPB")
#! Link("$(DEVICE):CHECKTH.INPB","$(DEVICE):MEASCNTTH.VAL")
#! Field("$(DEVICE):CHECKTH.Q",16777215,1,"$(DEVICE):CHECKTH.Q")
#! Field("$(DEVICE):CHECKTH.INPD",16777215,1,"$(DEVICE):CHECKTH.INPD")
#! Link("$(DEVICE):CHECKTH.INPD","$(DEVICE):DONETH.VAL")
#! Field("$(DEVICE):CHECKTH.INPU",16777215,1,"$(DEVICE):CHECKTH.INPU")
#! Field("$(DEVICE):CHECKTH.INPV",16777215,1,"$(DEVICE):CHECKTH.INPV")
#! Field("$(DEVICE):CHECKTH.SDIS",16777215,0,"$(DEVICE):CHECKTH.SDIS")
#! Link("$(DEVICE):CHECKTH.SDIS","$(DEVICE):STATE17.VAL")
#! Field("$(DEVICE):CHECKTH.INPI",16777215,1,"$(DEVICE):CHECKTH.INPI")
#! Field("$(DEVICE):CHECKTH.INPJ",16777215,1,"$(DEVICE):CHECKTH.INPJ")
#! Record("$(DEVICE):STATE17",1154,2201,0,1,"$(DEVICE):STATE17")
#! Field("$(DEVICE):STATE17.INPA",16777215,1,"$(DEVICE):STATE17.INPA")
#! Field("$(DEVICE):STATE17.INPB",16777215,1,"$(DEVICE):STATE17.INPB")
#! Link("$(DEVICE):STATE17.INPB","$(DEVICE):DONETH.VAL")
#! Field("$(DEVICE):STATE17.VAL",16777215,1,"$(DEVICE):STATE17.VAL")
#! Record("$(DEVICE):RESETSEQ17",1144,2895,0,0,"$(DEVICE):RESETSEQ17")
#! Field("$(DEVICE):RESETSEQ17.LNK1",16777215,1,"$(DEVICE):RESETSEQ17.LNK1")
#! Link("$(DEVICE):RESETSEQ17.LNK1","$(DEVICE):INITTH.VAL")
#! Field("$(DEVICE):RESETSEQ17.LNK2",16777215,1,"$(DEVICE):RESETSEQ17.LNK2")
#! Link("$(DEVICE):RESETSEQ17.LNK2","$(DEVICE):CHECKTH.VAL")
#! Field("$(DEVICE):RESETSEQ17.LNK3",16777215,1,"$(DEVICE):RESETSEQ17.LNK3")
#! Link("$(DEVICE):RESETSEQ17.LNK3","$(DEVICE):CHECKTH.Y")
#! Field("$(DEVICE):RESETSEQ17.LNK4",16777215,1,"$(DEVICE):RESETSEQ17.LNK4")
#! Link("$(DEVICE):RESETSEQ17.LNK4","$(DEVICE):CHECKTH.Z")
#! Field("$(DEVICE):RESETSEQ17.LNK5",16777215,1,"$(DEVICE):RESETSEQ17.LNK5")
#! Link("$(DEVICE):RESETSEQ17.LNK5","$(DEVICE):MEASCNTTH.VAL")
#! Field("$(DEVICE):RESETSEQ17.LNK6",16777215,1,"$(DEVICE):RESETSEQ17.LNK6")
#! Link("$(DEVICE):RESETSEQ17.LNK6","$(DEVICE):DONETH.VAL")
#! Field("$(DEVICE):RESETSEQ17.LNK8",16777215,1,"$(DEVICE):RESETSEQ17.LNK8")
#! Link("$(DEVICE):RESETSEQ17.LNK8","$(DEVICE):INITTH.VAL")
#! Record("$(DEVICE):INITTH",2010,2954,0,1,"$(DEVICE):INITTH")
#! Field("$(DEVICE):INITTH.VAL",16777215,0,"$(DEVICE):INITTH.VAL")
#! Field("$(DEVICE):INITTH.DOL",16777215,0,"$(DEVICE):INITTH.DOL")
#! Link("$(DEVICE):INITTH.DOL","$(DEVICE):CHECKTH.VAL")
#! Record("$(DEVICE):MODMATCHTH",1938,2448,0,0,"$(DEVICE):MODMATCHTH")
#! Field("$(DEVICE):MODMATCHTH.DOL",16777215,0,"$(DEVICE):MODMATCHTH.DOL")
#! Link("$(DEVICE):MODMATCHTH.DOL","$(DEVICE):CHECKTH.VAL")
#! Field("$(DEVICE):MODMATCHTH.FLNK",16777215,1,"$(DEVICE):MODMATCHTH.FLNK")
#! Link("$(DEVICE):MODMATCHTH.FLNK","$(DEVICE):MEASCNTTH")
#! Field("$(DEVICE):MODMATCHTH.VAL",16777215,1,"$(DEVICE):MODMATCHTH.VAL")
#! Record("$(DEVICE):DONETH",2530,2306,0,0,"$(DEVICE):DONETH")
#! Field("$(DEVICE):DONETH.FLNK",16777215,0,"$(DEVICE):DONETH.FLNK")
#! Link("$(DEVICE):DONETH.FLNK","$(DEVICE):STATE17")
#! Field("$(DEVICE):DONETH.INPC",16777215,0,"$(DEVICE):DONETH.INPC")
#! Link("$(DEVICE):DONETH.INPC","$(DEVICE):CHECKTH.Q")
#! Field("$(DEVICE):DONETH.VAL",16777215,0,"$(DEVICE):DONETH.VAL")
#! Record("$(DEVICE):MEASCNTTH",2266,2526,0,0,"$(DEVICE):MEASCNTTH")
#! Field("$(DEVICE):MEASCNTTH.FLNK",16777215,1,"$(DEVICE):MEASCNTTH.FLNK")
#! Link("$(DEVICE):MEASCNTTH.FLNK","$(DEVICE):DONETH")
#! Field("$(DEVICE):MEASCNTTH.VAL",16777215,0,"$(DEVICE):MEASCNTTH.VAL")
#! Field("$(DEVICE):MEASCNTTH.INPA",16777215,0,"$(DEVICE):MEASCNTTH.INPA")
#! Link("$(DEVICE):MEASCNTTH.INPA","$(DEVICE):MODMATCHTH.VAL")
#! Field("$(DEVICE):MEASCNTTH.INPB",16777215,0,"$(DEVICE):MEASCNTTH.INPB")
#! Link("$(DEVICE):MEASCNTTH.INPB","$(DEVICE):MEASCNTTH.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECKBR") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):18:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCHBR")
  field(INPA, "EDEF:$(LOC):18:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNTBR")
  field(INPD, "$(DEVICE):DONEBR")
  field(INPU, "EDEF:$(LOC):18:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):18:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE18")
  field(INPI, "EDEF:$(LOC):18:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):18:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE18") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):18:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONEBR")
}

record(seq, "$(DEVICE):RESETSEQ18") {
  field(DESC, "EDEF BR Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INITBR PP")
  field(LNK2, "$(DEVICE):CHECKBR")
  field(LNK3, "$(DEVICE):CHECKBR.Y")
  field(LNK4, "$(DEVICE):CHECKBR.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNTBR")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONEBR")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INITBR PP")
}

record(bo, "$(DEVICE):INITBR") {
  field(DOL, "$(DEVICE):CHECKBR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCHBR") {
  field(FLNK, "$(DEVICE):MEASCNTBR")
  field(DOL, "$(DEVICE):CHECKBR")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONEBR") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE18")
  field(INPC, "$(DEVICE):CHECKBR.Q")
}

record(calcout, "$(DEVICE):MEASCNTBR") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONEBR")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCHBR")
  field(INPB, "$(DEVICE):MEASCNTBR")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECKBR",1538,2184,0,0,"$(DEVICE):CHECKBR")
#! Field("$(DEVICE):CHECKBR.FLNK",16777215,1,"$(DEVICE):CHECKBR.FLNK")
#! Link("$(DEVICE):CHECKBR.FLNK","$(DEVICE):MODMATCHBR")
#! Field("$(DEVICE):CHECKBR.INPF",16777215,1,"$(DEVICE):CHECKBR.INPF")
#! Field("$(DEVICE):CHECKBR.INPP",16777215,1,"$(DEVICE):CHECKBR.INPP")
#! Field("$(DEVICE):CHECKBR.INPW",16777215,1,"$(DEVICE):CHECKBR.INPW")
#! Field("$(DEVICE):CHECKBR.Y",16777215,0,"$(DEVICE):CHECKBR.Y")
#! Field("$(DEVICE):CHECKBR.Z",16777215,0,"$(DEVICE):CHECKBR.Z")
#! Field("$(DEVICE):CHECKBR.VAL",16777215,1,"$(DEVICE):CHECKBR.VAL")
#! Field("$(DEVICE):CHECKBR.INPA",16777215,1,"$(DEVICE):CHECKBR.INPA")
#! Field("$(DEVICE):CHECKBR.INPB",16777215,1,"$(DEVICE):CHECKBR.INPB")
#! Link("$(DEVICE):CHECKBR.INPB","$(DEVICE):MEASCNTBR.VAL")
#! Field("$(DEVICE):CHECKBR.Q",16777215,1,"$(DEVICE):CHECKBR.Q")
#! Field("$(DEVICE):CHECKBR.INPD",16777215,1,"$(DEVICE):CHECKBR.INPD")
#! Link("$(DEVICE):CHECKBR.INPD","$(DEVICE):DONEBR.VAL")
#! Field("$(DEVICE):CHECKBR.INPU",16777215,1,"$(DEVICE):CHECKBR.INPU")
#! Field("$(DEVICE):CHECKBR.INPV",16777215,1,"$(DEVICE):CHECKBR.INPV")
#! Field("$(DEVICE):CHECKBR.SDIS",16777215,0,"$(DEVICE):CHECKBR.SDIS")
#! Link("$(DEVICE):CHECKBR.SDIS","$(DEVICE):STATE18.VAL")
#! Field("$(DEVICE):CHECKBR.INPI",16777215,1,"$(DEVICE):CHECKBR.INPI")
#! Field("$(DEVICE):CHECKBR.INPJ",16777215,1,"$(DEVICE):CHECKBR.INPJ")
#! Record("$(DEVICE):STATE18",1154,2201,0,1,"$(DEVICE):STATE18")
#! Field("$(DEVICE):STATE18.INPA",16777215,1,"$(DEVICE):STATE18.INPA")
#! Field("$(DEVICE):STATE18.INPB",16777215,1,"$(DEVICE):STATE18.INPB")
#! Link("$(DEVICE):STATE18.INPB","$(DEVICE):DONEBR.VAL")
#! Field("$(DEVICE):STATE18.VAL",16777215,1,"$(DEVICE):STATE18.VAL")
#! Record("$(DEVICE):RESETSEQ18",1144,2895,0,0,"$(DEVICE):RESETSEQ18")
#! Field("$(DEVICE):RESETSEQ18.LNK1",16777215,1,"$(DEVICE):RESETSEQ18.LNK1")
#! Link("$(DEVICE):RESETSEQ18.LNK1","$(DEVICE):INITBR.VAL")
#! Field("$(DEVICE):RESETSEQ18.LNK2",16777215,1,"$(DEVICE):RESETSEQ18.LNK2")
#! Link("$(DEVICE):RESETSEQ18.LNK2","$(DEVICE):CHECKBR.VAL")
#! Field("$(DEVICE):RESETSEQ18.LNK3",16777215,1,"$(DEVICE):RESETSEQ18.LNK3")
#! Link("$(DEVICE):RESETSEQ18.LNK3","$(DEVICE):CHECKBR.Y")
#! Field("$(DEVICE):RESETSEQ18.LNK4",16777215,1,"$(DEVICE):RESETSEQ18.LNK4")
#! Link("$(DEVICE):RESETSEQ18.LNK4","$(DEVICE):CHECKBR.Z")
#! Field("$(DEVICE):RESETSEQ18.LNK5",16777215,1,"$(DEVICE):RESETSEQ18.LNK5")
#! Link("$(DEVICE):RESETSEQ18.LNK5","$(DEVICE):MEASCNTBR.VAL")
#! Field("$(DEVICE):RESETSEQ18.LNK6",16777215,1,"$(DEVICE):RESETSEQ18.LNK6")
#! Link("$(DEVICE):RESETSEQ18.LNK6","$(DEVICE):DONEBR.VAL")
#! Field("$(DEVICE):RESETSEQ18.LNK8",16777215,1,"$(DEVICE):RESETSEQ18.LNK8")
#! Link("$(DEVICE):RESETSEQ18.LNK8","$(DEVICE):INITBR.VAL")
#! Record("$(DEVICE):INITBR",2010,2954,0,1,"$(DEVICE):INITBR")
#! Field("$(DEVICE):INITBR.VAL",16777215,0,"$(DEVICE):INITBR.VAL")
#! Field("$(DEVICE):INITBR.DOL",16777215,0,"$(DEVICE):INITBR.DOL")
#! Link("$(DEVICE):INITBR.DOL","$(DEVICE):CHECKBR.VAL")
#! Record("$(DEVICE):MODMATCHBR",1938,2448,0,0,"$(DEVICE):MODMATCHBR")
#! Field("$(DEVICE):MODMATCHBR.DOL",16777215,0,"$(DEVICE):MODMATCHBR.DOL")
#! Link("$(DEVICE):MODMATCHBR.DOL","$(DEVICE):CHECKBR.VAL")
#! Field("$(DEVICE):MODMATCHBR.FLNK",16777215,1,"$(DEVICE):MODMATCHBR.FLNK")
#! Link("$(DEVICE):MODMATCHBR.FLNK","$(DEVICE):MEASCNTBR")
#! Field("$(DEVICE):MODMATCHBR.VAL",16777215,1,"$(DEVICE):MODMATCHBR.VAL")
#! Record("$(DEVICE):DONEBR",2530,2306,0,0,"$(DEVICE):DONEBR")
#! Field("$(DEVICE):DONEBR.FLNK",16777215,0,"$(DEVICE):DONEBR.FLNK")
#! Link("$(DEVICE):DONEBR.FLNK","$(DEVICE):STATE18")
#! Field("$(DEVICE):DONEBR.INPC",16777215,0,"$(DEVICE):DONEBR.INPC")
#! Link("$(DEVICE):DONEBR.INPC","$(DEVICE):CHECKBR.Q")
#! Field("$(DEVICE):DONEBR.VAL",16777215,0,"$(DEVICE):DONEBR.VAL")
#! Record("$(DEVICE):MEASCNTBR",2266,2526,0,0,"$(DEVICE):MEASCNTBR")
#! Field("$(DEVICE):MEASCNTBR.FLNK",16777215,1,"$(DEVICE):MEASCNTBR.FLNK")
#! Link("$(DEVICE):MEASCNTBR.FLNK","$(DEVICE):DONEBR")
#! Field("$(DEVICE):MEASCNTBR.VAL",16777215,0,"$(DEVICE):MEASCNTBR.VAL")
#! Field("$(DEVICE):MEASCNTBR.INPA",16777215,0,"$(DEVICE):MEASCNTBR.INPA")
#! Link("$(DEVICE):MEASCNTBR.INPA","$(DEVICE):MODMATCHBR.VAL")
#! Field("$(DEVICE):MEASCNTBR.INPB",16777215,0,"$(DEVICE):MEASCNTBR.INPB")
#! Link("$(DEVICE):MEASCNTBR.INPB","$(DEVICE):MEASCNTBR.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECKF1") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):19:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCHF1")
  field(INPA, "EDEF:$(LOC):19:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNTF1")
  field(INPD, "$(DEVICE):DONEF1")
  field(INPU, "EDEF:$(LOC):19:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):19:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE19")
  field(INPI, "EDEF:$(LOC):19:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):19:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE19") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):19:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONEF1")
}

record(seq, "$(DEVICE):RESETSEQ19") {
  field(DESC, "EDEF F1 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INITF1 PP")
  field(LNK2, "$(DEVICE):CHECKF1")
  field(LNK3, "$(DEVICE):CHECKF1.Y")
  field(LNK4, "$(DEVICE):CHECKF1.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNTF1")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONEF1")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INITF1 PP")
}

record(bo, "$(DEVICE):INITF1") {
  field(DOL, "$(DEVICE):CHECKF1")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCHF1") {
  field(FLNK, "$(DEVICE):MEASCNTF1")
  field(DOL, "$(DEVICE):CHECKF1")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONEF1") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE19")
  field(INPC, "$(DEVICE):CHECKF1.Q")
}

record(calcout, "$(DEVICE):MEASCNTF1") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONEF1")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCHF1")
  field(INPB, "$(DEVICE):MEASCNTF1")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECKF1",1538,2184,0,0,"$(DEVICE):CHECKF1")
#! Field("$(DEVICE):CHECKF1.FLNK",16777215,1,"$(DEVICE):CHECKF1.FLNK")
#! Link("$(DEVICE):CHECKF1.FLNK","$(DEVICE):MODMATCHF1")
#! Field("$(DEVICE):CHECKF1.INPF",16777215,1,"$(DEVICE):CHECKF1.INPF")
#! Field("$(DEVICE):CHECKF1.INPP",16777215,1,"$(DEVICE):CHECKF1.INPP")
#! Field("$(DEVICE):CHECKF1.INPW",16777215,1,"$(DEVICE):CHECKF1.INPW")
#! Field("$(DEVICE):CHECKF1.Y",16777215,0,"$(DEVICE):CHECKF1.Y")
#! Field("$(DEVICE):CHECKF1.Z",16777215,0,"$(DEVICE):CHECKF1.Z")
#! Field("$(DEVICE):CHECKF1.VAL",16777215,1,"$(DEVICE):CHECKF1.VAL")
#! Field("$(DEVICE):CHECKF1.INPA",16777215,1,"$(DEVICE):CHECKF1.INPA")
#! Field("$(DEVICE):CHECKF1.INPB",16777215,1,"$(DEVICE):CHECKF1.INPB")
#! Link("$(DEVICE):CHECKF1.INPB","$(DEVICE):MEASCNTF1.VAL")
#! Field("$(DEVICE):CHECKF1.Q",16777215,1,"$(DEVICE):CHECKF1.Q")
#! Field("$(DEVICE):CHECKF1.INPD",16777215,1,"$(DEVICE):CHECKF1.INPD")
#! Link("$(DEVICE):CHECKF1.INPD","$(DEVICE):DONEF1.VAL")
#! Field("$(DEVICE):CHECKF1.INPU",16777215,1,"$(DEVICE):CHECKF1.INPU")
#! Field("$(DEVICE):CHECKF1.INPV",16777215,1,"$(DEVICE):CHECKF1.INPV")
#! Field("$(DEVICE):CHECKF1.SDIS",16777215,0,"$(DEVICE):CHECKF1.SDIS")
#! Link("$(DEVICE):CHECKF1.SDIS","$(DEVICE):STATE19.VAL")
#! Field("$(DEVICE):CHECKF1.INPI",16777215,1,"$(DEVICE):CHECKF1.INPI")
#! Field("$(DEVICE):CHECKF1.INPJ",16777215,1,"$(DEVICE):CHECKF1.INPJ")
#! Record("$(DEVICE):STATE19",1154,2201,0,1,"$(DEVICE):STATE19")
#! Field("$(DEVICE):STATE19.INPA",16777215,1,"$(DEVICE):STATE19.INPA")
#! Field("$(DEVICE):STATE19.INPB",16777215,1,"$(DEVICE):STATE19.INPB")
#! Link("$(DEVICE):STATE19.INPB","$(DEVICE):DONEF1.VAL")
#! Field("$(DEVICE):STATE19.VAL",16777215,1,"$(DEVICE):STATE19.VAL")
#! Record("$(DEVICE):RESETSEQ19",1144,2895,0,0,"$(DEVICE):RESETSEQ19")
#! Field("$(DEVICE):RESETSEQ19.LNK1",16777215,1,"$(DEVICE):RESETSEQ19.LNK1")
#! Link("$(DEVICE):RESETSEQ19.LNK1","$(DEVICE):INITF1.VAL")
#! Field("$(DEVICE):RESETSEQ19.LNK2",16777215,1,"$(DEVICE):RESETSEQ19.LNK2")
#! Link("$(DEVICE):RESETSEQ19.LNK2","$(DEVICE):CHECKF1.VAL")
#! Field("$(DEVICE):RESETSEQ19.LNK3",16777215,1,"$(DEVICE):RESETSEQ19.LNK3")
#! Link("$(DEVICE):RESETSEQ19.LNK3","$(DEVICE):CHECKF1.Y")
#! Field("$(DEVICE):RESETSEQ19.LNK4",16777215,1,"$(DEVICE):RESETSEQ19.LNK4")
#! Link("$(DEVICE):RESETSEQ19.LNK4","$(DEVICE):CHECKF1.Z")
#! Field("$(DEVICE):RESETSEQ19.LNK5",16777215,1,"$(DEVICE):RESETSEQ19.LNK5")
#! Link("$(DEVICE):RESETSEQ19.LNK5","$(DEVICE):MEASCNTF1.VAL")
#! Field("$(DEVICE):RESETSEQ19.LNK6",16777215,1,"$(DEVICE):RESETSEQ19.LNK6")
#! Link("$(DEVICE):RESETSEQ19.LNK6","$(DEVICE):DONEF1.VAL")
#! Field("$(DEVICE):RESETSEQ19.LNK8",16777215,1,"$(DEVICE):RESETSEQ19.LNK8")
#! Link("$(DEVICE):RESETSEQ19.LNK8","$(DEVICE):INITF1.VAL")
#! Record("$(DEVICE):INITF1",2010,2954,0,1,"$(DEVICE):INITF1")
#! Field("$(DEVICE):INITF1.VAL",16777215,0,"$(DEVICE):INITF1.VAL")
#! Field("$(DEVICE):INITF1.DOL",16777215,0,"$(DEVICE):INITF1.DOL")
#! Link("$(DEVICE):INITF1.DOL","$(DEVICE):CHECKF1.VAL")
#! Record("$(DEVICE):MODMATCHF1",1938,2448,0,0,"$(DEVICE):MODMATCHF1")
#! Field("$(DEVICE):MODMATCHF1.DOL",16777215,0,"$(DEVICE):MODMATCHF1.DOL")
#! Link("$(DEVICE):MODMATCHF1.DOL","$(DEVICE):CHECKF1.VAL")
#! Field("$(DEVICE):MODMATCHF1.FLNK",16777215,1,"$(DEVICE):MODMATCHF1.FLNK")
#! Link("$(DEVICE):MODMATCHF1.FLNK","$(DEVICE):MEASCNTF1")
#! Field("$(DEVICE):MODMATCHF1.VAL",16777215,1,"$(DEVICE):MODMATCHF1.VAL")
#! Record("$(DEVICE):DONEF1",2530,2306,0,0,"$(DEVICE):DONEF1")
#! Field("$(DEVICE):DONEF1.FLNK",16777215,0,"$(DEVICE):DONEF1.FLNK")
#! Link("$(DEVICE):DONEF1.FLNK","$(DEVICE):STATE19")
#! Field("$(DEVICE):DONEF1.INPC",16777215,0,"$(DEVICE):DONEF1.INPC")
#! Link("$(DEVICE):DONEF1.INPC","$(DEVICE):CHECKF1.Q")
#! Field("$(DEVICE):DONEF1.VAL",16777215,0,"$(DEVICE):DONEF1.VAL")
#! Record("$(DEVICE):MEASCNTF1",2266,2526,0,0,"$(DEVICE):MEASCNTF1")
#! Field("$(DEVICE):MEASCNTF1.FLNK",16777215,1,"$(DEVICE):MEASCNTF1.FLNK")
#! Link("$(DEVICE):MEASCNTF1.FLNK","$(DEVICE):DONEF1")
#! Field("$(DEVICE):MEASCNTF1.VAL",16777215,0,"$(DEVICE):MEASCNTF1.VAL")
#! Field("$(DEVICE):MEASCNTF1.INPA",16777215,0,"$(DEVICE):MEASCNTF1.INPA")
#! Link("$(DEVICE):MEASCNTF1.INPA","$(DEVICE):MODMATCHF1.VAL")
#! Field("$(DEVICE):MEASCNTF1.INPB",16777215,0,"$(DEVICE):MEASCNTF1.INPB")
#! Link("$(DEVICE):MEASCNTF1.INPB","$(DEVICE):MEASCNTF1.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(doubSub, "$(DEVICE):CHECKF2") {
  field(DESC, "Check if Pulse Used")
  field(SNAM, "evrPatternSimTest")
  field(INPF, "$(DEVICE):MODIFIER4")
  field(INPP, "EDEF:$(LOC):20:INCLUSION4 CA")
  field(INPW, "$(DEVICE):BEAMCODE.SEVR")
  field(BRSV, "INVALID")
  field(FLNK, "$(DEVICE):MODMATCHF2")
  field(INPA, "EDEF:$(LOC):20:CTRL CA")
  field(INPB, "$(DEVICE):MEASCNTF2")
  field(INPD, "$(DEVICE):DONEF2")
  field(INPU, "EDEF:$(LOC):20:INCLUSION2 CA")
  field(INPV, "EDEF:$(LOC):20:INCLUSION3 CA")
  field(DISV, "0")
  field(SDIS, "$(DEVICE):STATE20")
  field(INPI, "EDEF:$(LOC):20:AVGCNT CA")
  field(INPJ, "EDEF:$(LOC):20:MEASCNT CA")
}

record(calcout, "$(DEVICE):STATE20") {
  field(DESC, "Change Processing State")
  field(CALC, "B?0:A")
  field(INPA, "EDEF:$(LOC):20:CTRL CPP")
  field(HOPR, "1")
  field(OOPT, "On Change")
  field(INPB, "$(DEVICE):DONEF2")
}

record(seq, "$(DEVICE):RESETSEQ20") {
  field(DESC, "EDEF F2 Reset Sequence")
  field(SELM, "All")
  field(LNK1, "$(DEVICE):INITF2 PP")
  field(LNK2, "$(DEVICE):CHECKF2")
  field(LNK3, "$(DEVICE):CHECKF2.Y")
  field(LNK4, "$(DEVICE):CHECKF2.Z")
  field(DOL5, "0")
  field(LNK5, "$(DEVICE):MEASCNTF2")
  field(DOL6, "0")
  field(LNK6, "$(DEVICE):DONEF2")
  field(DOL1, "1")
  field(DOL8, "0")
  field(LNK8, "$(DEVICE):INITF2 PP")
}

record(bo, "$(DEVICE):INITF2") {
  field(DOL, "$(DEVICE):CHECKF2")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(bo, "$(DEVICE):MODMATCHF2") {
  field(FLNK, "$(DEVICE):MEASCNTF2")
  field(DOL, "$(DEVICE):CHECKF2")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(calcout, "$(DEVICE):DONEF2") {
  field(CALC, "C?1:0")
  field(FLNK, "$(DEVICE):STATE20")
  field(INPC, "$(DEVICE):CHECKF2.Q")
}

record(calcout, "$(DEVICE):MEASCNTF2") {
  field(DESC, "pulses counted")
  field(PINI, "YES")
  field(FLNK, "$(DEVICE):DONEF2")
  field(VAL, "0")
  field(HOPR, "280000")
  field(LOPR, "-1")
  field(MDEL, "0")
  field(CALC, "A?B+1:B")
  field(INPA, "$(DEVICE):MODMATCHF2")
  field(INPB, "$(DEVICE):MEASCNTF2")
}

#! Further lines contain data used by VisualDCT
#! View(1829,2001,1.0)
#! Record("$(DEVICE):CHECKF2",1538,2184,0,0,"$(DEVICE):CHECKF2")
#! Field("$(DEVICE):CHECKF2.FLNK",16777215,1,"$(DEVICE):CHECKF2.FLNK")
#! Link("$(DEVICE):CHECKF2.FLNK","$(DEVICE):MODMATCHF2")
#! Field("$(DEVICE):CHECKF2.INPF",16777215,1,"$(DEVICE):CHECKF2.INPF")
#! Field("$(DEVICE):CHECKF2.INPP",16777215,1,"$(DEVICE):CHECKF2.INPP")
#! Field("$(DEVICE):CHECKF2.INPW",16777215,1,"$(DEVICE):CHECKF2.INPW")
#! Field("$(DEVICE):CHECKF2.Y",16777215,0,"$(DEVICE):CHECKF2.Y")
#! Field("$(DEVICE):CHECKF2.Z",16777215,0,"$(DEVICE):CHECKF2.Z")
#! Field("$(DEVICE):CHECKF2.VAL",16777215,1,"$(DEVICE):CHECKF2.VAL")
#! Field("$(DEVICE):CHECKF2.INPA",16777215,1,"$(DEVICE):CHECKF2.INPA")
#! Field("$(DEVICE):CHECKF2.INPB",16777215,1,"$(DEVICE):CHECKF2.INPB")
#! Link("$(DEVICE):CHECKF2.INPB","$(DEVICE):MEASCNTF2.VAL")
#! Field("$(DEVICE):CHECKF2.Q",16777215,1,"$(DEVICE):CHECKF2.Q")
#! Field("$(DEVICE):CHECKF2.INPD",16777215,1,"$(DEVICE):CHECKF2.INPD")
#! Link("$(DEVICE):CHECKF2.INPD","$(DEVICE):DONEF2.VAL")
#! Field("$(DEVICE):CHECKF2.INPU",16777215,1,"$(DEVICE):CHECKF2.INPU")
#! Field("$(DEVICE):CHECKF2.INPV",16777215,1,"$(DEVICE):CHECKF2.INPV")
#! Field("$(DEVICE):CHECKF2.SDIS",16777215,0,"$(DEVICE):CHECKF2.SDIS")
#! Link("$(DEVICE):CHECKF2.SDIS","$(DEVICE):STATE20.VAL")
#! Field("$(DEVICE):CHECKF2.INPI",16777215,1,"$(DEVICE):CHECKF2.INPI")
#! Field("$(DEVICE):CHECKF2.INPJ",16777215,1,"$(DEVICE):CHECKF2.INPJ")
#! Record("$(DEVICE):STATE20",1154,2201,0,1,"$(DEVICE):STATE20")
#! Field("$(DEVICE):STATE20.INPA",16777215,1,"$(DEVICE):STATE20.INPA")
#! Field("$(DEVICE):STATE20.INPB",16777215,1,"$(DEVICE):STATE20.INPB")
#! Link("$(DEVICE):STATE20.INPB","$(DEVICE):DONEF2.VAL")
#! Field("$(DEVICE):STATE20.VAL",16777215,1,"$(DEVICE):STATE20.VAL")
#! Record("$(DEVICE):RESETSEQ20",1144,2895,0,0,"$(DEVICE):RESETSEQ20")
#! Field("$(DEVICE):RESETSEQ20.LNK1",16777215,1,"$(DEVICE):RESETSEQ20.LNK1")
#! Link("$(DEVICE):RESETSEQ20.LNK1","$(DEVICE):INITF2.VAL")
#! Field("$(DEVICE):RESETSEQ20.LNK2",16777215,1,"$(DEVICE):RESETSEQ20.LNK2")
#! Link("$(DEVICE):RESETSEQ20.LNK2","$(DEVICE):CHECKF2.VAL")
#! Field("$(DEVICE):RESETSEQ20.LNK3",16777215,1,"$(DEVICE):RESETSEQ20.LNK3")
#! Link("$(DEVICE):RESETSEQ20.LNK3","$(DEVICE):CHECKF2.Y")
#! Field("$(DEVICE):RESETSEQ20.LNK4",16777215,1,"$(DEVICE):RESETSEQ20.LNK4")
#! Link("$(DEVICE):RESETSEQ20.LNK4","$(DEVICE):CHECKF2.Z")
#! Field("$(DEVICE):RESETSEQ20.LNK5",16777215,1,"$(DEVICE):RESETSEQ20.LNK5")
#! Link("$(DEVICE):RESETSEQ20.LNK5","$(DEVICE):MEASCNTF2.VAL")
#! Field("$(DEVICE):RESETSEQ20.LNK6",16777215,1,"$(DEVICE):RESETSEQ20.LNK6")
#! Link("$(DEVICE):RESETSEQ20.LNK6","$(DEVICE):DONEF2.VAL")
#! Field("$(DEVICE):RESETSEQ20.LNK8",16777215,1,"$(DEVICE):RESETSEQ20.LNK8")
#! Link("$(DEVICE):RESETSEQ20.LNK8","$(DEVICE):INITF2.VAL")
#! Record("$(DEVICE):INITF2",2010,2954,0,1,"$(DEVICE):INITF2")
#! Field("$(DEVICE):INITF2.VAL",16777215,0,"$(DEVICE):INITF2.VAL")
#! Field("$(DEVICE):INITF2.DOL",16777215,0,"$(DEVICE):INITF2.DOL")
#! Link("$(DEVICE):INITF2.DOL","$(DEVICE):CHECKF2.VAL")
#! Record("$(DEVICE):MODMATCHF2",1938,2448,0,0,"$(DEVICE):MODMATCHF2")
#! Field("$(DEVICE):MODMATCHF2.DOL",16777215,0,"$(DEVICE):MODMATCHF2.DOL")
#! Link("$(DEVICE):MODMATCHF2.DOL","$(DEVICE):CHECKF2.VAL")
#! Field("$(DEVICE):MODMATCHF2.FLNK",16777215,1,"$(DEVICE):MODMATCHF2.FLNK")
#! Link("$(DEVICE):MODMATCHF2.FLNK","$(DEVICE):MEASCNTF2")
#! Field("$(DEVICE):MODMATCHF2.VAL",16777215,1,"$(DEVICE):MODMATCHF2.VAL")
#! Record("$(DEVICE):DONEF2",2530,2306,0,0,"$(DEVICE):DONEF2")
#! Field("$(DEVICE):DONEF2.FLNK",16777215,0,"$(DEVICE):DONEF2.FLNK")
#! Link("$(DEVICE):DONEF2.FLNK","$(DEVICE):STATE20")
#! Field("$(DEVICE):DONEF2.INPC",16777215,0,"$(DEVICE):DONEF2.INPC")
#! Link("$(DEVICE):DONEF2.INPC","$(DEVICE):CHECKF2.Q")
#! Field("$(DEVICE):DONEF2.VAL",16777215,0,"$(DEVICE):DONEF2.VAL")
#! Record("$(DEVICE):MEASCNTF2",2266,2526,0,0,"$(DEVICE):MEASCNTF2")
#! Field("$(DEVICE):MEASCNTF2.FLNK",16777215,1,"$(DEVICE):MEASCNTF2.FLNK")
#! Link("$(DEVICE):MEASCNTF2.FLNK","$(DEVICE):DONEF2")
#! Field("$(DEVICE):MEASCNTF2.VAL",16777215,0,"$(DEVICE):MEASCNTF2.VAL")
#! Field("$(DEVICE):MEASCNTF2.INPA",16777215,0,"$(DEVICE):MEASCNTF2.INPA")
#! Link("$(DEVICE):MEASCNTF2.INPA","$(DEVICE):MODMATCHF2.VAL")
#! Field("$(DEVICE):MEASCNTF2.INPB",16777215,0,"$(DEVICE):MEASCNTF2.INPB")
#! Link("$(DEVICE):MEASCNTF2.INPB","$(DEVICE):MEASCNTF2.VAL")
#! TextBox(TB7,1809,2873,2129,3013,0,"Dialog",12,1,16777215,"EVR IOCs monitor $(DEVICE):INIT records to know when to reset, in order to reset their counters, etc, ahead of the first beam pulse.",null)
#! TextBox(TB6,816,2728,1336,2848,0,"Dialog",12,0,16777215,"EVG RESET$MD records\n* Processed when EDEF CTRL is processed.  .\n* Processed before any  device or EVG GO record is turned on so EVG always reset first\n* Resets EVG CHECK$MDID VAL to \"no match\", Y to \"not seen\" and Z to \"first time\"\n   (all these conditions are 0)\n* EVG CHECK processing then properly initialized and device AVGCNT records\n   will do nothing until EVG CHECK processing begins ",null)
#! TextBox(TB5,845,2477,1325,2677,0,"Dialog",12,0,16777215,"EVG STATE$MD and GO$MD\n* GO$MD records are Initialized to SCAN=PASSIVE\n* STATE$MD will set SCAN=IO_Intr when EDEF CTRL is ON\n* Device support will then interrupt at up to 360hz and cause GO$MD to process\n* GO$MD then processes it's FLNK (EVG CHECK$MDID \n* STATE$MD will set SCAN=PASSIVE when EDEF CTRL is OFF\n  and device support will no longer cause processing of GO$MD\n* STATE$MD is processed whenever EDEF CTRL is changed",null)
#! TextBox(TB3,2201,2892,2333,3050,0,"Dialog",12,1,16777215,"EVG sets Init upon pattern match for this EDEF so that EVR IOC EDEF recipeint can prepare (init its records) for when its modifier bit comes (PNET match + 2 ahead). It then clears on next cycle.",null)
#! TextBox(TB2,1879,2694,2258,2730,0,"Dialog",12,1,16777215,"Use the Modifier Match MODMATCH pv to enable EDEF.\n",null)
#! TextBox(TB1,1314,1887,1514,1967,0,"Dialog",13,1,16777215,"Macros:\nIOC = 4 char IOC name\nMD = measdef number\nMDID = measdef ID",null)