SAPE/ELP – 00X

Booster Injection and Extraction Kicker

OPERATION MANUAL

 

Prepared by: _Fernando Rafael                                                     Date:                                

Signature: _________________________                                

 

Reviewed by: _Marjorie Widmeyer                                                 Date:                                

Signature: ______ ___________________                                

 

Approved by: __Ben Scott                                                               Date:                                

Signature: _________________________

                                                                                                           

Please check for the latest changes before using this procedure.  Please review SLAC’s Lock and Tag Program for general rules, which may not be covered in this procedure. The absence of a validation date and signatures indicates that the attached procedure has not been validated. The first person(s) to perform the attached Steps is responsible for validating them according to the instructions below.

Validation Instructions

Technical Steps should be validated by two persons -one to act out the procedure and one to record discrepancies or improvements. If there are no discrepancies or improvements to recommend, write the date and your name and signature below and send this sheet to SSRL/LOTO (Lock Out Tag Out) Coordinator, MS 69. If there are discrepancies or improvements to recommend, mark them on the attached procedure. Write the date and your name below; do not sig n. Send this sheet and the procedure to SSRL/LOTO (Lock Out Tag Out) Coordinator, MS 69.

 

Date of validation: _____________________________________

 

Name of Person 1: _____________________________________

      < /span>        Signature: _____________________________________

 

Name of Person 2: _____________________________________

              Signature: _____________________________________


 

Revision Modification List

Rev/Mod

Number

Des cription

Revised by

Date

 

 

 

 

 < /p>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

< /td>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Index

Revision Modificati on List 2

Index. 3

Figures Index< span style='mso-tab-count:1 dotted'>. 3

Kicker Control System.. 4

Operation Manual 4

1.     PanelView Operation: 4

2.      Login. 4

3.     Selection of the kicker 4

a.     Injection: 4

b.     Extraction: 6

4.     Contact and Questions. 8

 

 

Figur es Index

 

Figure 1 - Initial Display. 4

Figure 2 – Injection Kicker Display . 5

Figure 3 – Injection Interlock Display. 6

Figure 4 – High Voltage Power Supply. 6

Figure 5 – Extraction Kicker Display. 7

Figure 6 – Extraction Interlock Display. 8

 


Kicker Control System

Operation Manual

 

1.    PanelView Operation:

 

  1. Login In the initial display (Figure 1) select “Login” button, enter the password  “123”  press “return”.

 

 

Figure 1 - Initial Display

 

  1. Selection of the kicker you would like to operate in the Figure 1:

a.     Injection:

   &nbs p;                                                          i.      Select “Injection Kicker” button,

                                & nbsp;                           ii.      In Injection Kicker Display (Figure 2) power the rack on, selecting the “Turn On” button under “Control Rack” label. The thyratron fil ament inside the booster tunnel will start to heating, after 3 minutes all interlock should be clear and no warning should be shown In this case go to item Error! Reference source not found.. Otherwise, the message box above “Interlock” button is flashing in red.

                                                          iii.      Select the button “Interlock” to access the Injection Kicker Interlock Display (Figure 1). Press “Reset” button and identify the fault. The fault condition will flash in red. Clear the fault and press the “reset” button again. If is all in blue, press “Return”.

 

 

                              ;                              iv.      Press the button “Turn ON” under “high Voltage” label in the Figure 2. The button will change to blue and HV ON will appear.

 

 

Figure 2 – Injection Kicker Display

 

                                                             v.      Go to the power supply ide ntified as Injection Kicker and power the unit on (Figure 4). Push the green key to enable the high Voltage output. The gage will show the selected voltage (CAMAC)

 

 

Figure 3 – Injection Interlock Display

Line Callout 3: Enable the High Voltage
 


Line Callout 3: Power ON
 the unit

 

Figure 4 – High Voltage Power Supply

 

b.     Extraction:

 

                                                            vi.      Select “Extraction Kicker” button,

 

                                                         vii.      In Extraction Kicker Display (Figure 6) power the rack on, selecting the “Turn On” button under “Control Rack” label. The thyratron filament inside the booster tunnel will start to heating, after 3 minutes, all interlock should be clear and no warning should be shown In this case go to item Error! Reference source not found.. Otherwise, the message box above “Interlock” button is flashing in red.

 

 

                                                       viii.      Select the button “Interlock” to access the Extraction Kicker Interlock Display (Figure 5Figure 1). Press “Reset” button and identify the fault. The fault condition will flash in red. Clear the fault and press the “reset” button again. If is all in blue, press “Return”.

  ;

                                                            ix.      Press the button “Turn ON” under “High Voltage” label in the Figure 2. The button will change to blue and HV ON will appear.

 

 

     &n bsp;                                                       x.      Go to the power supply identified as Extraction Kicker and power t he unit on (Figure 4Figure 6). Push the green key to enable the high Voltage output. The gage will show the selected voltage (CAMAC)

 

 

Figure 5 – Extraction Kicker Display

 

 

 

 

Figure 6 – Extraction Interlock Display

 