Amplitude & Phase Calibration
Rev. 2
S. Smith
27 Aug 2002
I&Q
Measurement
Goal:
Translate I&Q measurements from SIS digitizers to amplitude and phase using
I&Q calibration parameters.
Given
a vector of I and Q values from the waveform digitizers: Ij Qj
and
calibration data:
I & Q pedestals Iped,
Qped
Gains gI, gQ
Quadrature angle fq
Channel Phase angle f0
Define
·
Quadrature
angle error d = fq – 90o
·
and
Correct
for pedestals and gains: I’j
= gI(Ij - Iped) , Q’j = gQ(Qj - Qped)
Adjust for quadrature error: VjI
= cI’j + sQ’j VjQ
= sI’j + qQ’j
Amplitude:
Phase: fj = tan-1(Qj/Ij)
- f0
I&Q Control
Goal:
Translate desired I&Q components to I&Q DAC values using calibration
parameters.
Given
a vector of I and Q values: I, Q
and
calibration data:
I & Q pedestals Iped,
Qped
Gains gI, gQ
Quadrature angle fq
Channel Phase angle f0
Define
·
Quadrature
angle error d = fq – 90o
·
and
·
De-skewing
matrix:
·
Channel
Phase rotation matrix:
·
Gain
Correction Matrix:
Transformation: