Received: from [134.79.72.91] (134.79.72.91) by email.slac.stanford.edu
 (134.79.106.208) with Microsoft SMTP Server (TLS) id 8.1.436.0; Thu, 30 Sep
 2010 16:25:12 -0700
From: "Hill, Bruce" <bhill@slac.stanford.edu>
To: "Chaiken, Alison" <alison@slac.stanford.edu>
Date: Thu, 30 Sep 2010 16:25:12 -0700
Subject: Re: PCDS "event" module and BSA hardware
Thread-Topic: PCDS "event" module and BSA hardware
Thread-Index: Actg9rtWemAcWDmqRPm20iTFgQUKXg==
Message-ID: <4CA51C58.70104@slac.stanford.edu>
References: <4CA3C6F4.7020306@slac.stanford.edu>
In-Reply-To: <4CA3C6F4.7020306@slac.stanford.edu>
Accept-Language: en-US
Content-Language: en-US
X-MS-Exchange-Organization-AuthAs: Internal
X-MS-Exchange-Organization-AuthMechanism: 0a
X-MS-Exchange-Organization-AuthSource: EXCH-CLIENT1.win.slac.stanford.edu
X-MS-Has-Attach:
X-MS-TNEF-Correlator:
user-agent: Thunderbird 2.0.0.24 (X11/20100903)
Content-Type: text/plain; charset="iso-8859-1"
Content-Transfer-Encoding: quoted-printable
MIME-Version: 1.0

Hi Alison,
I'm not clear on what you're asking.   Have you used the eBeam version=20
of the event
module with MRF EVR's?    If so, there's not really anything different=20
about our
event module other than running on a linux box.     We're using PMC EVR230
modules, so we use a Technobox PCIe carrier card to mount them in the PCIe
slots on our linux boxes.     They get a fiber from our MRF timing=20
fanout board
and the event module gets the fiducial from the EVR hardware and uses it=20
to set
the EPICS timestamp.   When our camera module timestamps it's image, it get=
s
the current EPICS timestamp.    Since the shutter duration is much=20
longer than
a fiducial interval, the fiducial in the timestamp is not the same as=20
the fiducial when
the camera was triggered, but that has not been an issue for us as these=20
camera images
are used for viewing and don't go into data aquisition.

- Bruce

Alison Chaiken wrote:
> Bruce, thanks again for the source code and advice you provided me with=20
> before.       I'm starting to think about what EVR hardware I might need=
=20
> for BSA correlation of camera images with other data in FACET.   It's my=
=20
> understanding from your previous message that the "event" module that=20
> you pointed me to provides this correlation.   Can you please point me=20
> to any diagram or documentation that explains how the hardware portion=20
> of the system (the signal propagation) is hooked up?    Thanks for your=20
> assistance.
>
>  =20

--=20
Bruce Hill
Member Technical Staff
SLAC National Accelerator Lab
2575 Sand Hill Road M/S 10
Menlo Park, CA  94025