SLAC 
Welcome






Damping Ring Klystron Inventory and Operating Parameters

Last modified: September 10, 2007


Inventory

S/N Tube Type Solenoid Location Status Vac Ion Pump Warranty Runtime Notes
J7-11 VA-955H Varian VA-1955H S/N 0157 NDR Socket Online No No 15,840+ 6-8-2006 Installed in NDR Socket 4-8-04
J6-101VKP-7855 Premier VA-1955H S/N 0123 SDR Socket Online Yes No 25,056 6-8-2006 Installed in SDR socket 6-8-2006
C7-08 VA-955H   Test Lab Failed No No 77,184+ 6-8-2006 Removed from SDR socket 6-8-2006.Tube water leak.
001 VKP-7855 Varian VA-1955H S/N 0101R. SDR Vault Good Spare Yes Yes 0 New Tube 2-21-07
H4-159 VKP-7555S Varian VA-1955H S/N E7-011R NDR Vault Good Spare Yes No 0 8-30-2006 Rebuilt at CPI



Manufacture's Test Data

S/N Tube Type Filament Voltage Filament Current Magnet Current Beam Voltage Beam Current Mode-
Anode
Body Current Power Output Drive Power Gain
H4-159VKP-7555S7.0 Vac17.8 Aac29.0 Adc24.5 KVdc6.33 Adc0 KVdc48 mAdc64.5 KW.69 W49.7db
J7-11VA-955H7.0 Vac18.1 Aac25.0 Adc24.5 KVdc6.33 Adc21.5 KVdc49 mAdc67 KW.67 W50.0db
C7-08VA-955H7.0 Vac16.7 Aac30.0 Adc24.0 KVdc7.2 Adc24.0 KVdc58 mAdc64 KW.55 W50.7db
J6-101VKP-78556.5 Vac16.8 Aac30.0 Adc23.0 KVdc7.0 AdcEb=Emod53.6 mAdc65.0 KW.23 W54.5db
001VKP-78556.5 Vac16.8 Aac 26 Adc24.5 KVdc6.10 Adc21.8 KVdc21 mAdc 64.8 kW1.07 W47.8 dB
J6-101VKP-78556.5 Vac16.8 Aac28.0 Adc24.5 KVdc6.33 Adc21.4 KVdc58.6 mAdc66.0 KW.20 W55.2db


Magnet data

Serial Number Type Manufacturer
0157Tape woundPremier Microwave
E7-011RWire woundVarian
0101RTape woundVarian

Suffix R means rebuilt.


Recent History of Damping Ring Klystrons


           
 Date             Description


 09-07-07   NDR    Replaced rubber bellows and air filters.

 09-07-07   SDR    Replaced rubber bellows and air filters.

 03-27-07   SDR    Klystron SN 001 moved to SDR vault.

 02-21-07          New Klystron SN 001 dressed with magnet 0101R moved to sector 1 cage. Good Spare.

 08-30-06   NDR    H4-159 moved to NDR as good spare (in magnet E7-011R). Tube was repaired at CPI.

 08-24-06   NDR    Replaced rubber bellows and air filters.

 08-24-06   SDR    Replaced rubber bellows and air filters.

 06-14-06          C8-507 Tube scrapped.

 06-08-06   SDR    J6-101 installed in SDR socket. High body current ~40ma, frequently trips. Bellows replaced.

 06-08-06   SDR    C7-08 Removed from SDR socket. Water leak on tube. Moved to test lab.

 01-18-06   SDR    C7-08 installed in SDR socket. Water leak was repaired at test lab. Tube has very small water leak.

 01-18-06   SDR    J6-101 removed from SDR socket. Good spare. Left in SDR vault.

 01-18-06   SDR    C8-507 moved from SDR vault to test lab.
 
 01-01-06   SDR    C8-507 has very poor emission. Removed C8-507 and installed J6-101 in SDR socket.

 08-03-04   SDR    Replaced Bellows and air filters.

 08-02-04   NDR    Replaced Bellows and air filters.

 04-08-04   NDR    Installed J7-11 in socket (From Sector 1 crate). Installed magnet: 
		   Varian VA-1955H S/N 0157 off klystron H4-159.
    
                   Installed H4-159 (Dressed Spare From NDR Vault). Klystron tripped on 
		   body current and RF instability ~18KV.  Removed.    

		   Removed C7-08. Water leak, possible damage to klystron or 
		   magnet.
		 
		
 08-13-03   NDR    Replaced Bellows, replaced air filters, vacuumed RF cabinet,
	  	   and checked RF cables. 


 08-13-03   SDR    Replaced Bellows, replaced air filters, vacuumed RF cabinet,
  		   and checked RF cables.           

 
 07-02      SDR    C8-507 Tested for suspected low gain. NTF. Good Spare

  
 04-16-02   SDR    Installed J6-101 in Socket.

 
 04-16-02   SDR    Removed C8-507. Low gain
                   Left tube in vault to test during downtime. 


 04-15-02   SDR    Replaced bellows.


 12-14-00   NDR    Replaced bellows. Possible damage from welding.


 10-19-00   NDR    Replaced bellows. water leak.
 
 
 10-12-99   C8-507 Installed in magnet S/N E7-011R. Installed in SDR socket.
                   RTM 79414.1
 
 10-12-99   J7-11  Removed from SDR socket. Crated and stored in sector 1 cage.
                   Tube is good spare.
                  
 
 07-12-99   J6-101 Moved to SDR vault (magnet S/N 0123), dressed spare.
 
 
 07-12-99   H4-159 Moved to NDR vault (magnet S/N 0157), dressed spare.	
 
 
 06-04-99   H4-159 Water leak repaired at SLAC. Magnet 0157 rebuilt.
                   H4-159 installed in magnet S/N 0157 and moved to
                   sector 1 cage. 


 12-04-98   J6-101 Installed in magnet S/N 0123. Moved to sector 1 cage as 
               	   dressed spare.


 12-01-98   H4-159 and magnet 0123 moved to test lab.


 11-29-98   H4-159 Tube water leak, klystron removed from SDR
                  socket, Moved to Sector 1 cage. Magnet S/N 0123.


 11-29-98   J7-11  Installed in SDR socket (magnet S/N E7-011R).



 06-01-98   J6-101 Magnet S/N 0157 shorted, klystron removed from 
                   SDR socket.


            H4-159 Installed in SDR socket (magnet S/N 0123). 



 04-01-98   C8-507 New klystron purchased. Stored in sector 1 cage in
                   shipping crate.



 03-18-98   J7-11  Moved to NDR vault (magnet S/N E7-011R), dressed spare.



 03-18-98   H4-159 Moved to SDR vault (magnet S/N 0123), dressed spare.



 03-16-98   J7-11  Hydro tested by Test Lab.
                  Moved to sector 1 cage as spare.
 
 
 02-23-98   J7-11  Installed in magnet S/N E7-011R.
                  At test lab for evaluation.
                    
 
            H4-159 Installed in magnet 0123 after magnet water leak
                  repaired. Stored at sector 1 cage as spare. 
 
 
 02-19-98   J7-11  Removed from SDR due to magnet (S/N 0123) water leak.
 
            J6-101 Installed in SDR with magnet 0157.
 
          

 02-11-98   H4-159 Removed from SDR due to body current faults. 
  
            J7-11  Installed in SDR socket.




 02-10-98   J7-11  Moved to SDR vault as SDR spare.   




 12-15-97   J6-101 Installed in solenoid 0157. Dressed and stored at
                   sector 1 cage. Good Spare.   

            0157   Solenoid water leak repaired at SLAC.




 10-22-97   J6-101 NDR online klystron solenoid (0157) leaking water.
                   Removed klystron and solenoid to Sector 1 cage. 
                   RTM 24054.

            C7-08  Installed in NDR socket with solenoid 0101R.



 09-18-97   C7-08  Installed in solenoid 0101R. Dressed and stored at
                   sector 1 cage. Good Spare.   



 09-17-97   J7-11  Installed in solenoid 0123. Dressed and stored at
                   sector 1 cage. Good Spare.   

            0123   Solenoid water leak repaired at SLAC.
          
            0101R  Solenoid gauss levels checked at SLAC. See Ron Akre 
                   for results.
            


 09-09-97   J7-11  SDR Online klystron solenoid (S/N 0123) developed a 
                   water leak.
                   Klystron and solenoid removed from socket. 

            H4-159 Installed in SDR socket with solenoid S/N E7-011R.



 09-08-97   E7-011R Solenoid water leak repaired at SLAC.

            H4-159 installed in solenoid E7-011R, moved to sector 1 cage.
                   Dressed spare.



 09-03-97   H4-159 SDR online klystron magnet (E7-011R) leaking water. 
                   Klystron and
                   solenoid removed from socket and sent to Test Lab for 
                   analysis.
           
            J7-11  Installed in SDR socket with solenoid S/N 0123.
 
 

 06-24-97   J7-11  placed in solenoid 0123. Dressed for spare.
 


 06-20-97   0123   Solenoid rebuilt by Premier Microwave. Arrived at SLAC
                   6-19-97.
                  
                  
                  
 06-19-97   J6-101 NDR online klystron (J6-101) removed from solenoid 
                   101R due to poor focus. 
                   Installed in solenoid 157, reinstalled J6-101 in NDR 
                   socket. 
                  


 06-13-97   J7-11  NDR klystron magnet 157 leaking water from water input 
                   and output connectors. Removed klystron from NDR 
                   socket. 
                  
            J6-101 Installed in NDR socket.
  
  
  
 06-04-97   C6-14  Crated up and delivered to Test Lab for shipping to 
                   repair facility.

            J6-101 Installed in magnet 0101R and dressed as Damping Ring 
                   spare.           



 05-29-97   C6-14  NDR online klystron tripped on body current. When 
                   reset, klystron had an IK of zero Amps and poor vacuum. 

            J7-11  Installed in NDR socket.
           
           
           
 01-13-97   C7-08  NDR kly magnet failure. 
                   Removed from NDR vault, removed from magnet and stored 
                   in shipping crate at sector 1 cage. Magnet VA-1955H 
                   S/N 0123 readied for shipment to repair facility.
        
            C6-14  Installed in NDR socket.


          
 12-01-96   J6-101 Arrives from CPI. Left in crate, stored at sector 01 
                   cage.



 01-08-96   C1-19  Removed from SDR socket due to no emission, eventually 
                   scrapped.
               
            H4-159 New klystron, placed in magnet, installed in SDR 
                   socket.
		
		
		
 12-11-95   C6-14  SDR kly filament open, ion pump connector broke, tube 
                   down to air. 
   
            C1-19  Installed in SDR socket. 
         
            C6-14: Gun repaired, new tuners installed at CPI.
                   Returned to SLAC 4-26-96
	
		
		
 11-95      H4-159 New Spare in box in sector 01.

            C1-19  SDR spare. Rebuilt PEP tube - previous rebuild at 
                   California Tube.
		
            C6-14  SDR socket.
 		
            J7-11  NDR spare.
 		
            C7-08  NDR socket
 				
		
		
 03-22-95   J7-11  Removed due to short in magnet E7-011R.
         
            C6-14  Installed  in SDR socket. 
		
		
						     
 01-23-95   H7-11  Removed from NDR socket- internal arcing at gun. 
 	       
            C7-08  Installed in NDR socket.    
		
            H7-11  Damaged beyond repair in shipment to Varian. (Scrap)
		
            D7-11  Coupler on D7-11 broken,
                   Shipped to Varian for repair - beyond repair. (Scrap)

  
  
 01-21-95   C6-14  Removed  from SDR socket due to water leak. Installed 
                   J7-11 in SDR socket. (Water leak repaired at Test Lab).         







AMRF's Home Page

This page is maintained by Dave Steele