LER QD (PR08 LGPS 101)

LER PR08 LGPS 101 (QD) Paramters:
Magnet Unit(s)

Most of LER arc

defocusing

quadrupoles

Typical BDES -19.451 kG
Typical Current 300 A
Typical PS Voltage 500 V
Nominal Beta X 4.7 m
Nominal Eta X 0.33
Nominal Beta Y 25 m
Nominal Eta Y 0.0 m

Lattice Description

LER QD powers most of the LER arc QD magnets.

The LER has 6 arcs, each with 16 QD magnets.

In general the LER arcs have QFs and QDs each powered in series for the whole ring excect for the first few arc magnets which surround straights 2, 4 and 12. For the arcs which surround these straights, the first ~6 quadrupole magnets are powered locally to match the dispersion into the straight and in the case of straight 2, make a beta bump to enhance the effect of local sextupoles.