ABSTRACT
ICALEPCS 2001

Abstracts



WECI001 (Invited)

Presenter: Glenn Decker (Advanced Photon Source)
email: decker@aps.anl.gov
Review Status: Proceedings Ready - 02/01/02
FullText: pdf
Transparencies: pdf
Eprint: physics/0112043

Orbit Feedback Using X-ray Beam Position Monitoring at the Advanced Photon Source

G. A. Decker, O. V. Singh

The Advanced Photon Source was commissioned in 1995 as a third generation x-ray user facility. At that time, orbit control was performed exclusively with broadband rf beam position monitors. Since then, emphasis has been placed on incorporating x-ray beam position monitors into the orbit control algorithms. This has resulted in an order of magnitude improvement in long term beam stability vertically, using x-ray bpm's on bending magnet beamlines. Additional processing will allow similar improvements horizontally, once systematic effects associated with variable insertion device x-ray beams are properly compensated. Progess to date and upgrade plans will be presented, with an emphasis on the details of the required digital signal processing.
ICAL Footer

  eCONF C011127    ePROCEEDINGS COMMITTEES PARTICIPANTS    PROGRAM SUMMARY ICALEPCS 2001  eCONF

 

ICALEPCS 2001