Electromagnetic Calorimeter Trigger Electronic Logbook Highlights

Period: 15th January 1999

Directories:

Constants:  /nfs/bbr-srv2/dataflow/constants/emt/runNNNN.*
EMT xtc files: $BFROOT/detector/trg/emt
EMC datfiles: $BFROOT/detector/emc/datfiles

Tools:

Run inspection:  ~mcfall/inspect/inspect_run  <startRun>  <endRun>
TC checking:  ~dauncey/R7.8.2/tcchecker*
 

Documents:

Latest versions of EMT documentation.

 

Date @Time

Run

Triggers

Run Notes

Hardware

Firmware

Software

15/1/99 2 GLT cables wrongly connected, 1&3=TPB0&2.  This was status for data on 10/1/99.
Sun 17/1/99 500 EMT, GLT, EMC
Tue 19/1/99 Readphase was set to FF in latency.fcx. 
Changed to 6.
Wed 21/1/99 Set read delay value to 20. 
 
'Out of order' errors fixed by fixing FCX. Plots from EMT and GLT show a 2-bin shift in phi.
EMC on-data electronics overheated.
23/1/99 run0709.ax 
run0709.fcx 
run0709.fx 
run0709.mask 
run0714.fcx 
run0716.fcx 
run0717.ax
24/1/99 
Runs 0726-0775 
 
EMT->GLT cables were incorrectly connected. Fixed. run0769.ax 
run0775.ax
Loaded new version of GLT FEX in L1EmtCalOdf. 
Run 755 was corrupted.
761 First run with EMT
767 ONLY 2M trigger 300 events, crashed from `out of sync'.
769 2M with EMT in separate partition.
25/1/99 
Runs 0776-0822
777  run0777.mask
26/1/99 
Runs 0823-0841
Close L1As, 'out of sync' and 'out of order'.  Caused by L1A during ReadEvent. run0831.ax 
run0831.mask
@ 0940 TPB26 in slot 5 loaded with AX V9.0.  Boots ok.
@ 1800 replaced AX V8.12
27/1/99 
Runs 0842-0873
28/1/99 
Runs 0875-0888
run0885.ax 
run0885.mask 
run0888.ax
Used online 2.3.2
@ 1900 Half of endcap was used. First attempt at Frameclash.
@2100 EMC 10/40 not connected. 
Included in next run.
885 EMC, EMT, DCH, DCT, IFR 53k events.
@2330 888 (probably, number overwritted in paper logbook) Scan AX configuration values Time alignment set to 2 = 0x4000
29/1/99 
Runs 0889-0953
run0891.ax 
run0892.ax 
run0930.mask
@0015 889 2M*  GLT event display shows cosmics with EMT alone.
@0030 890 EMC crashed immediately (3k events)
@0045 891 Time alignment = 4 = 0x8000
892 Alignment back to 3=0x6000
@~1700 Changed all AX from ESP 8.12 to ESP 9.1.
30/1/99 
Runs 0954-1013
run0992.mask 
run0995.ax 
run1001.ax
@~0900 EMC ROM problem; EMC out of run 982->, but EMT still in!
@1445 995 -> 997 Junk run Time alignment = 0x8000
998 Time alignment 3=0x6000
@1655 999 Went full (?) 
Whole front barrel lit up!!!
@1512 1001 Using correct libs and run0995.ax, time alignment = 4. 
Next run time align = 3.
31/1/99 
Runs 1014-1096
1/2/99 EMC: All UPC firmware changed and all IOBs modified.
Fri 5/2/99@~1900 First data taken using own trigger (0x4000). Using pulser, went to 95Hz before 'out of order' error.
11/2/99 
Run 1098
run1098.fcx
12/2/99 
Runs 1099-1102
14/2/99 
Runs 1103-1104
15/2/99 EMC: All ADBs removed and modified to correct CARE problem.
16/2/99 
Runs 1105-1108
17/2/99 
Runs 1109-1112
18/2/99 
Runs 1114-1120
19/2/99 
Runs 1122-1135
EMC: `Out-of-order' damage resolved. 
Scan runs to check for hot towers (no endcap).
1128 Theta6
1129 Theta5
1130 Theta4
1131 Theta3
1132 Theta2
1133 Theta1
20/2/99 
Runs 1136-1143
run1136.mask
21/2/99 
Runs 1144-1173
Repeat scan runs after checking UPC cables plugged into UPCs correctly. 
Runs 1145-1150 had calorimeter off => deleted. 
Theta6->1; Runs 1157-1163.
run1152.mask 
run1164.fcx 
run1164.mask 
run1165.fcx 
run1166.fcx 
run1167.mask 
run1168.fcx 
run1169.fcx 
run1170.fcx 
run1171.fcx 
run1172.fcx 
run1173.fcx
1164 Readphase = 7
1165 Readphase = 3
1168 Readphase = 7
1169 Readphase = 6
1170 Readphase = 9 (?)
1171 Readphase = 3
1172 Readphase = 1
EMC: Frame offset was being set to 3. Changed to 8 for running tonight.
22/2/99 
Runs 1174-
Frame offset = 8 
Repeat theta mask for single towers; higher statistics.
run1179.mask
1175 Tower3, 22k events 
EMC crate4 [B0] missing, so UPCs going into Theta4.5.6, Phi0-2 could be bad.
1176 Tower4, 33k events 
EMC crate4 [B0] missing, so UPCs going into Theta4.5.6, Phi0-2 could be bad.
1177 Tower2, 5k events
1178 Tower5, 37k events
23/2/99 Test runs to look at weird tower summers.