FECs FWD EndCap status
Summary of FECs with problems and substitution...
--> First FECs change performed on: 23rd January 2003. (Last)
Legenda:
-- OP: Old Problem. FEC appears in this condition since the reference calibration on 19th November 2002.
-- NP: New Problem. FEC appears in this condition on the reference calibration on 22nd January 2003.
-- R: FEC replaced.
Endcap East
- FE0 All OK (6Feb03)
- FE1
-- B06 #11: 1 hot channel (OP)
- FE2 All OK (6Feb03)
- FE3 All OK (6Feb03)
- FE4
-- E03 #4: 1 dead channel (NP)
-- E03 #14: 1 dead channel (NP)
-- E02 #6: few dead channels (OP)
-- E02 #7: few dead channels (OP)
-- E01 #2: 1 dead channel (NP)
- FE5
-- F04 #1: dead (NP, 23 Jan03) testing pin broken
-- F04 #13: dead (OP), OK (R, 23Jan03)
-- F04 #15: dead (OP), OK (R, 23Jan03)
-- F04 #16: dead (OP), OK (R, 23Jan03)
- FE6 All OK (6Feb03)
- FE7
-- D06 #16: dead (OP), OK (R, 23Jan03)
Endcap West
- FW0
-- B04 #13: dead (OP), OK (R, 23Jan03)
-- B04 #16: dead (OP), dead (R, 23Jan03)
- FW1
-- B06 #8: hot (OP)
-- B08 #6: dead (OP), OK (R, 23Jan03)
-- B08 #7: dead (OP), OK (R, 23Jan03)
- FW2
-- C02 #11: 1 channel hot (OP)
-- C03 #8: 1 channel hot (OP)
- FW3
-- C07 #8: few channels dead (OP), dead (R, 23Jan03)
-- C07 #9: dead (OP), OK (R, 23Jan03)
-- C07 #13: 1/2 channels dead (OP), dead (R, 23Jan03)
- FW4
-- E03 #1: dead (OP), OK (R, 23Jan03)
-- E01 #3: 1 dead channel (NP)
- FW5
-- F04 #8: 1 dead channel (NP)
-- F02 #1: dead (NP), OK (R, 23Jan03)
- FW6
-- A07 #3: 1 hot channel (OP), 1 hot channel (R, 23Jan03)
-- A06 #8: 1 hot channel (OP)
-- A06 #12: dead (OP)
- FW7
-- D09 #5: 1 dead channel (OP)
-- D07 #12: 1 dead channel (OP)
-- D07 #15: 1 dead channel (OP)
Last updated: 06 Feb 2003