Data Format
|
|
Last modified: 18 October 1998
Where to find the data:
-
$BFROOT/data/data03/dcdata/dch
- This is where you can find the data files. Files are named
runnnn where nnn is the run number.
- The data files are copied to this NFS directory before being written to the tape.
- Interesting data are kept here as long as the space allows, while junk runs are erased after copying to the tape.
- Tape in the silo
- The data are written to a tape in the silo for archiving. The tape can be read from SLAC server machines (e.g. morgan and percheron) using
stagein command.
How to stagein:
The easiest and recommended way is:
cd $BFROOT/data/data03/dcdata/dch
revive runXXX
The script revive will send a correct request to the staging system, which will read in the data to a staging disk and create a symbolic link runXXX for you. Don't mind if the link is already there, or if the data
itself is there: revive and stagein will (at least should) take care of all the details.
| Run |
Start Date/Time |
Events |
HV |
Threshold |
Readout/Calibration |
Status |
Comments |
QA plots |
| 1658 |
6/25/98 |
20K |
2020V |
240mV |
9 FEAs read out: a full vertical wedge, and three wedges with only two boxes (FEAs 1 and 2) instrumented |
GOOD |
|
ps file and hot/dead channels |
| 1674 |
6/28/98 |
20K |
2020V |
240mV |
9 FEAsread out |
GOOD |
possible instabilities in gas composition |
ps file and hot/dead channels |
| 1678 |
6/29/98 |
20K |
2020V |
240mV |
6 FEAs, forming two complete chamber wedges |
GOOD |
Warning: Repeated events have been found, most likely present in previous runs as well! |
ps file and hot/dead channels ChebyCal ChebyCon |
| 1688 |
7/01/98 |
7K |
2020V |
240mV |
23 FEAs read out, forming a complete lower quadrant and nearly complete upper quadrant (one box missing). |
OK |
the wire mapping was not correct for the lower quadrant (it appears as a side quadrant). So rather than seeing straight tracks going through all 80 layers, you'll see two tracks with phi differing by pi/2.
One of the trigger 'wires' was noisy, reconstuction uses only one trigger 'wire' but the corresponding TOF correction is still missing; result: degraded resolution
|
ps file and hot/dead channels ChebyCal ChebyCon |
| 1690 |
7/03/98 |
20K |
2020V |
240mV |
22 FEA's read out, forming a complete lower quadrant and nearly complete upper quadrant (outer two FEAs in wedge with least acceptance are missing |
|
wire mapping should be fixed |
ChebyCal ChebyCon |
| 1719 |
7/11/98 |
40K |
2020V |
240mV |
3 wedges: 4,5,12, which will appear as 3,4,11 |
Done |
Half of the events have the bit 0x80000 ("BAD_DATA") set in the event flag, meaning that the online software detected an error in the data format (the offline code needs to be updated to recognize this bit, I think). The "bad" events will
have 16 dead channels in the outer FEA of wedge 5 (the wedge that will seem to be wedge 4) |
ps file hot/dead channels ChebyCal ChebyCon |
| 1731 |
7/22/98 |
11K |
2020 |
240 |
24 FEAS in quadrants 1 and 3. |
Done |
Only 2/8 FEAS in superlayer 1 have hits (wedge 7 and 8). There is a hole in wedge 5, superlayer 4. |
ps file hot/dead channels ChebyCal ChebyCon |
| 1732 |
7/22/98 |
11K |
2020 |
240 |
as above |
Done |
as above |
ps file hot/dead channels ChebyCal ChebyCon |
| 1749 |
7/23/98 |
21K |
2020 |
190 |
as above |
Done |
as above |
ps file hot/dead channels ChebyCal ChebyCon |
| 1764 |
7/31/98 |
20K |
1960 |
190 |
2 quadrants |
v4 |
Time of hits in lower quadrant is 80ns late.This prevents tracks being found in lower quadrant. Now corrected for in DchProto |
ps file hot/dead channels ChebyCal ChebyCon |
| 1791 |
8/4/98 |
20K |
1960 |
200 |
Quads 0 and 2 |
v4 |
|
ps file hot/dead channels ChebyCal ChebyCon |
| 1800 |
8/5/98 |
20K |
1960 |
190 |
Quads 0 and 2 |
v4 |
The same layers that are noisey in quads 1 and 3 are noisey in this run. |
ps file hot/dead channels ChebyCal ChebyCon |
| 1801 |
8/6/98 |
40K |
1960 |
200 |
Quads 0 and 2 |
v4 |
|
ps file hot/dead channels |
| 1804 |
8/10/98 |
20K |
1960 |
210 |
Quads 1 and 3 |
|
OEP Format |
|
| 1807 |
8/11/98 |
? |
1960 |
200 |
Quads 0 and 2 |
|
Pro2 Format |
not yet hot/dead channels |
| 1813 |
8/12/98 |
40K |
1960 |
200 |
Quads 1 and 3 |
|
Pro2 Format. The center trigger has been used and delayed so that most tracks should be in the rear of the chamber |
ps file hot/dead channels ChebyCal ChebyCon |
| 1842 |
8/23/98 |
50K |
1960 |
200 |
Quads 0+2, lab38 |
|
OEP Format |
|
| 1847 |
8/23/98 |
50K |
1960 |
200 |
Quads 0+2, lab38 |
|
OEP Format |
|
| 1848 |
8/23/98 |
? |
1960 |
200 |
Quads 1+3, lab42 |
|
OEP Format |
|
| 1849 |
8/23/98 |
53K |
1960 |
200 |
Quads 0+2, lab38 |
|
OEP Format |
|
| 1850 |
8/24/98 |
100K |
2020 |
200 |
Quads 0+2, lab38 |
|
OEP Format |
|
| 1853 |
8/24/98 |
500 |
2020 |
200 |
Quads 0+2, lab44 |
|
P2 Format, automatic loading of calibration files (but not used by P2 Format data). This run had a memory leak. |
|
| 1854 |
8/24/98 |
50K |
2020 |
200 |
Quads 1+3, lab43 |
|
As above; memory leak fixed. |
ps file hot/dead channels ChebyCal ChebyCon |
| 1855 |
8/24/98 |
2K |
2020 |
200 |
Quads 1+3, lab43 |
|
As above |
|
| 1856 |
8/24/98 |
50K |
2020 |
200 |
Quads 0+2, lab44 |
|
As above
|
ps file |
| 1859 |
8/24/98 |
5K |
2020 |
200 |
Quads 1+3, lab46 |
|
OEP format; memory leak |
|
| 1860 |
8/24/98 |
7K |
2020 |
200 |
Quads 1+3, lab46 |
|
As above
|
|
| 1866 |
8/25/98 |
55K |
2020 |
200 |
Quads 0+2, lab45 |
|
As above; leak fixed? |
|
| 1867 |
8/25/98 |
50K |
2020 |
200 |
Quads 0+2, lab45 |
|
As above; rear trigger
|
ps file |
| 1868 |
8/25/98 |
50K |
2020 |
200 |
Quads 1+3, lab46 |
|
As above; rear trigger |
ps file |
| 1869 |
8/25/98 |
51K |
2020 |
200 |
Quads 1+3, lab46 |
|
As above; back to normal trigger
|
|
| 1870 |
8/25/98 |
49K |
2020 |
200 |
Quads 0+2, lab45 |
|
As above
|
|
| 1876 |
8/25/98 |
50K |
2020 |
200 |
Quads 0+2, lab45 |
|
Rear Trigger
|
|
| 1877 |
8/25/98 |
28K |
2020 |
200 |
Quads 1+3, lab48 |
|
Rear Trigger
|
|
| 1879 |
8/25/98 |
20K |
2020 |
200 |
Quads 1+3, lab48 |
|
Rear Trigger
|
|
| 1886 |
8/25/98 |
35K |
2020 |
220 |
Quads 1+3, lab48 |
|
As above; SL1 guard/zipper wire voltages changed to reflect use of different diameter wires
|
|
| 1887 |
8/25/98 |
50K |
2020 |
210 |
Quads 1+3, lab54 |
|
As above
|
|
| 1889 |
8/25/98 |
50K |
1960 |
200 |
Quads 0+2, lab53 |
|
As above
|
|
| 1892 |
8/26/98 |
52K |
1960 |
200 |
Quads 1+3, lab54 |
|
As above
|
|
| 1895 |
8/26/98 |
90K |
1960 |
200 |
Quads 1+3, lab55 |
|
As above; rear trigger
|
|
| 1911 |
8/27/98 |
50K |
2020 |
220 |
Quads 0+2, lab67 |
|
Fee2, wedge 9 and Fee3, wedge 5 replaced/repaired; final HV cables in final segmentation; all quads calibrated before run (lab67,lab69)
|
ps file |
| 1912 |
8/27/98 |
50K |
2020 |
220 |
Quads 1+3, lab69
|
|
Rear Trgger
|
ps file |
| 1913 |
8/27/98 |
50K |
2020 |
210 |
Quads 0+2, lab67 |
|
As above
|
|
| 1917 |
8/27/98 |
90K |
2020 |
220 |
Quads 0+2, lab67 |
|
As above
|
|
| 1919 |
8/27/98 |
100 |
2020 |
200 |
Quads 1+3, lab69 |
|
As above
|
|
| 1920 |
8/27/98 |
49K |
2020 |
200 |
Quads 0+2, lab67 |
|
As above; fmon on
|
|
| 1921 |
8/28/98 |
50K |
2020 |
240 |
Quads 0+2, lab102 |
|
Random Trigger
|
|
| 1923 |
8/28/98 |
50K |
2020 |
200 |
Quads 1+3, lab101 |
|
Rear Trigger
|
|
| 1925 |
8/28/98 |
16K |
2020 |
190 |
Quads 1+3, lab101 |
v3 |
As above
|
ps file |
| 1926 |
8/28/98 |
42K |
2080 |
190 |
Quads 1+3, lab101 |
v3 |
As above
|
ps file |
| 1930 |
8/28/98 |
43K |
1960 |
190 |
Quads 0+2, lab110 |
v4 |
As above
|
ps file |
| 1931 |
8/28/98 |
50K |
1960 |
190 |
Quads 1+3, lab109 |
v4 |
As above
|
ps file |
| 1932 |
8/29/98 |
50K |
1960 |
200 |
Quads 0+2, lab110 |
v3 |
Center Trigger
|
ps file |
| 1933 |
8/29/98 |
50K |
1960 |
200 |
Quads 1+3, lab109 |
v4 |
Center Trigger
|
ps file |
For comments, questions or changes to this page contact Fergus Wilson
|